This solicitation is for elevator maintenance and repair services at the Naval Surface Warfare Center Philadelphia Division (NSWCPD). The contractor shall provide all labor, supervision, tools, equipment, materials and supplies necessary to maintain and repair elevators located at various buildings on the NSWCPD campus. A site visit will be held on 24 January 2022 to familiarize offerors with the equipment and facilities. Questions are due by 26 January 2022, with proposals due in accordance with Sections L and M of the solicitation. The contractor shall perform preventative maintenance, repairs, inspections, load testing, and emergency services. The period of performance is one base year with four option years.
View the file
Other files for this federal contract opportunity
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ECSI Sercice Calls 20-21
PWS ATTACHMENT 4 - NSWCPD ELEVATOR HISTORICAL SERVICE CALLS
| SERVICE CALL # | CAR # | BLDG # | DESCRIPTION | DATE | E/R | COMPLETION DATE | BEYOND SCOPE (Y/N) | ACTUAL LABOR HOURS | ACTUAL MAT'L COST | REPAIR | TICKET # |
| A-001 | AFW-88 | 1000 | car not responding to hall calls | 24/Jul/2020 | R | 29/Jul/2020 | N | Door pickup roller assembly was crushed. Install new part and back in service | TC-22040 | ||
| A-002 | AFW-77 | 1000 | car is stuck on the 4th deck | 30/Jul/2020 | R | 30/Jul/2020 | N | Unit toggle switch was turned off at box. The safety switch for the door locks was inactive. Put the switch back in service. | TC-22051 | ||
| A-003 | AFW-88 | 1000 | there is a cable hanging from the car near the door | 7/Aug/2020 | R | 30/Jul/2020 | N | The door had a cable hanging from it. I verified this and the cable was broken. Also found that the interlock assembly is broken. Will need to return and replace both. Unit out of service. Picked up parts and returned on 8/7/20 to install interlock assembly and cable. Tested unit and left in service | TC-22052 | ||
| A-004 | AFW-90 | 1000 | car is on the 1st deck and will not respond to hall or car calls. Car doors will open and close. | 30/Jul/2020 | R | 30/Jul/2020 | N | Unit toggle was turned off in the box. Found the safety circuit open. I put the switch back to normal position. Tested and returned to service. | TC-22053 | ||
| A-005 | AFW-78 | 1000 | car gate is not fully closing (very slow to close when it does) | 30/Jul/2020 | R | 30/Jul/2020 | N | Unit was running but the door had a problem with the limits causing it to act abnormally. Took information for the limit sensor that needs to be replaced. Unit in service. | TC-22054 | ||
| A-006 | AFW-88 | 1000 | 1st floor doors are not closing all the way. Car has been taken out of service via penthouse disconnect. | 18/Sep/2020 | R | 18/Sep/2020 | N | 4 hours | $0.00 | Found the car on the 1st floor with the doors approximately 2 inches from being fully closed and the power off in the motor room. I went to the motor room and visually checked the door circuit relays and they appeared to be good. I next physically moved the relays in the door circuit and they appeared to be in working order. I turned the power on and put in a car call and could see all the proper relays energize but the car did not move. I went to the car and the doors were still two inches apart from being fully closed. I separated the car and hall doors and could feel that the doors were hitting something at that point. I put the car in access and ran the car up to where I could work on it from inside the car. I found the interlock contacts on the stationary keeper side were being hit by the keeper at a point in the contact that pushed the contact backwards instead of down. I adjusted the contact so it would not come up so much and slightly tilted the keeper so it would go into the interlock box and make contact with the interlock contacts. I also sanded down the hall door hangar tracks and lightly lubricated all moving parts on the hall doors. I ran and tested the car with no issues and left car in service. | TC-23590 |
| A-007 | AFW-98 | 1000 | car is stuck on 2nd deck | 24/Sep/2020 | R | 25/Sep/2020 | N | 7 hours | $0.00 | Arrived at the site and found the elevator shutdown. Indicator showed the 2nd floor but the elevator was stuck between the 2nd and 3rd floors. I went directly to the computer to see the fault being displayed and found fault 1 active. Translated and it said that the elevator run timer expired. This means that the elevator was traveling to a floor but for some reason took too much time and that timer finished counting and that shutdown the elevator in between floor. When I read this I reset the controller and the microprocessor unit. I put unit in inspection and was running with the breaks picked, so the unit was extremely slow and won't move down. I verified and troubleshoot the Break circuit, finding a problem in the Break contactor(BK2) that was not picking and sending voltage to the coil of the brakes to perform the command of open. I tested and verified this contactor but was found in operation, I verified the respective electrical circuits that energizes this contactor, and found that the RELAY STOP WAS BAD. The relay would energize but one of the contacts (11,2) was not sending the voltage to the A1 and A2 break contactor coil to close it and then send voltage to the break coil. I replaced this RELAY, I had a spare in the machine room so I used this one. Instantly the brakes would open and the car would move normally. I tested a lot and verified the equipment and the break unit was now operational. Performing this test I could perceive a small sound coming from inside the motor, like a small cracking sound, but I did not see any harm in the motor and I did not see any visible of performance problems with the motor, I did not touched anything of this equipment, I will keep an eye in the preventative visits and if found something abnormal will notify. Tested the unit operation from inside in all floors with Dan, I tested and left in normal operation. | TC-23821 |
| A-008 | AFW-78 | 1000 | car is stuck on 3rd deck and doors will not work | 26/Oct/2020 | R | 26/Oct/2020 | N | Found car on third floor with doors open. Went to motor and had no power to the main line. I was told the circuit breaker had tripped once before, so before we rest it I checked out the controller, looking for wires that could be grounded. Only found a bunch of lantern flies in one of the resistors and they were cooked. Removed lantern flies and went to first floor to reset breaker after receiving permission to do so. Back to the car and still had no power. Went back to the motor room and found two main line fuses had blown, both 60 amps. I changed both and we were able to run the car with no issues. Left in service.- | TC-24914 | ||
| A-009 | AFW-77 | 1000 | car is stuck on 4th deck and will not respond to calls | 28/Oct/2020 | R | 28/Oct/2020 | N | Unit was shutdown on arrival. I checked the main line power but it did not have power to the top three terminals in the disconnect switch. The disconnect had power. I verified again and the fuses in the main line disconnect were blown. Cause unknown. Will need to order new fuses. Left out of service. | TC-25141 | ||
| A-010 | AFW-88 | 1000 | investigate hall door operation on each floor. Per the NAVFAC inspector, "the door pick-up rollers on AFW-88 need some TLC soon. Each floor is adjusted differently or has a different problem." | 18/Nov/2020 | R | N | 2 | During last maintenance I found the crank arm link bearing broken. I came today to replaced the whole link with new bearing. I tested and adjusted it. Tested in all floors numerous times. Tested and left back in service. | TC-28697 | ||
| A-011 | AFW-78 | 1000 | the elevator is stuck on the 3rd floor and will not move | 25/Nov/2020 | R | N | |||||
| A-012 | AFW-90 | 1000 | elevator is stuck on the 4th floor with the doors open and will not respond to calls or door close button | 10/Dec/2020 | R | 11/Dec/2020 | N | 4 | $0 | Arrived at the building and troubleshoot the unit and found the input 00 ZNR not active. This causes the unit doors to be disconnected. Went floor by floor to very all interlock switches. Found the first floor was not active, which I repaired and put elevator back in service. | TC-25815 |
| A-013 | AFW-77 | 1000 | passenger stuck in elevator. Navy Fire Department responded and removed passenger from elevator. Disconnect power in the machine room. | 14/Dec/2020 | R | 16/Dec/2020 | N | 4 | Unit found shutdown. Unit was found shutdown at the 4th floor in between 4 and 3rd floors. I opened the door and inspected the locks, gate, sensors and release cam for any problems. I found everything normal. I went up and found the disconnect switch off. I tested fuses for any blown one. Was normal. I turned the power on and tested the unit in all floors. 1,2,3,4, and from top to bottom numerous times to replicate for any issue. But I did not found any. This controller is an old relay unit, and when the power is turned on it releases the relays and if I had a issue this panel does not have the resources to keep a fault list of events or anything. I continued and verified the car gate door and found that the problem with the sheave is getting worse and had a lot of first from the sheave. I decided to leave the elevator shutdown because if this part breaks the whole car gate door will fall into any passenger, it can cause serious injury to passengers and for this reason is best to leave it shutdown until it is fixed. I will notify the office for this repair. Left the elevator locked out and tagged. Return and meet with Bob Nazian to show him the Pelle parts that need repair. | TC-25874 & TC-28698 | |
| A-014 | AFW-94 | 4 | elevator doors are not closing properly on any floor. The car's breaker in penthouse was opened to prevent doors from constantly trying to close | 21/Dec/2020 | R | 22/Dec/2020 | Y | 5 | Arrived at service call and found unit at the top floor with doors not able to close, they were reopening. I verified and opened the sensors, I found water damage in the curtains. After that I went to see the main board in the car top and I saw marks of water all over the car top. Verified the Curtain board and it was bad with water damage too. I tested and declared that the board is bad and the curtain, this needs to be replaced. The generator guy came in and said that they had a water overflow in the weekend and that water came down to the elevator, this explain all the marks and the water damage. I saw water in one of the interlocks of the door, I will recommend to open them and take water out. The safety edge needs to be replaced with new one and needs to be retrofit into this controller. I left unit shutdown and turned off for approval. | TC-25934 | |
| A-015 | AFW-90 | 1000 | elevator is responding intermittently. The car has stopped on several floors and the doors are reported as not closing. The car has been reported as not responding to hall calls. | 23/Dec/2020 | R | 8/Jan/2021 | N | 2 | Found the interlock for the retiring cam was not lifting like 1/4" less so it was not letting the elevator leave the fourth floor. Adjusted and tested elevator operation. Left in service | TC-28928 | |
| A-016 | AFW-90 | 1000 | Doors are not closing automatically on 4'th floor (hall doors stop short of fully closing on 4'th floor, car does not respond to hall calls until doors are closed with the close button and the button held down for an extended period). | 4/Jan/2021 | R | N | |||||
| A-017 | AFW-97 | 633 | doors have an intermittent door closing issue. They are reported to begin to close, then reopen before closing again. Please investigate. | 8/Jan/2021 | R | 1/8/2021 & 2/3/21 | N | 1.25 & 3.5 | I got on the elevator and went to each floor and discovered the problem. Cleaned out the floor guide rails on each floor and the doors worked fine. Tested and left unit in service. TC-26536 Got on car top and cleaned the special Lens on the back. This resolved the issue. Took the information for the type of lens and voltage. Left in service | Did while doing maintenance and TC-26536 | |
| A-018 | AFW-96 | 633 | Investigate elevator doors opening and closing repeatedly without any human input. | 3/Feb/2021 | R | N | |||||
| A-019 | AFW-88 | 1000 | doors are closing too soon. Please adjust increase time doors remain open. | 5/Feb/2021 | R | N | |||||
| A-020 | #1 | 77H | Breaker was found tripped for elevator. Coworker is reporting elevator is making a lot of noise and rough starting but then greatly improves once car begins to travel. | 11/Feb/2021 | R | 12/Feb/2021 | N | 7 & 13 | Rode elevator and felt the harsh start and also squeaking. Went to control room and made adjustments to the unit up acceleration (#2). Made additional adjustments while helper operated elevator until the ride was smoother. While performing this I noticed the wires for the pressure switches were missing insulation. Recovered with electrical tape and noted that the switch will need replacement. Also found 2 rollers on the bottom limit switches and lubricated them. This was causing the squeaking. Tested and left in service. March 31 returned and installed new pressure switch. Tested and left in service. Also performed PM. | TC-26625 | |
| A-021 | AFW-93 | 4 | Dispatch was reporting elevator phone was calling them. | 16/Feb/2021 | R | 17/Feb/2021 | N | 2 | Elevator was turned off, waiting for repair. I verified that phone was okay. I opened panel and found water marks on phone button. Needs to be replaced. | TC-26676 | |
| A-022 | AFW-97 | 633 | AFW-97 is on the first floor and not responding to hall or car calls. | 22/Feb/2021 | R | 22/Feb/2021 | N | 4 | Unit was running. Verified and tested, the only problem identified was the safety edge reopening when not commanded to. This needs to be replaced and was previously reported during monthly maintenance. Problem cannot be resolved until replaced. | TC-26766 | |
| A-023 | AFW-90 | 1000 | car is not leveling properly | 2/Mar/2021 | 3/Mar/2021 | N | 4 | Adjusted floor leveler zone and tested | TC-26926 | ||
| A-024 | AFW-44 | 29 | Car is on mezzanine and not responding to calls | 16/Mar/2021 | 16/Mar/2021 | N | 5 | Upon arrival I observed the 1st floor hall call button with its light on indicating that it had been pressed but the car never came. Dan and I found the car on the M floor. The car door would open if a hall call was pressed but the car wouldn't move. The doors appeared to be closed completely so We went on top of the car. The top of the car including the selector tape and the magnets appeared to be in working order. We went to the motor room and I checked the fuses which using my meter read okay, next I checked the safety circuit using the print tapped to the wall. The safety circuit was open. We reset the car and it came down. We went in the car and cleaned the tracks in the car and the M floor. We wiped down the car door hanging track and cleaned up the rollers. The track had a grease ramp which we sanded and then light lubricated and the rollers had grease coming out of them. We cleaned the grease and again lightly lubricated the car door track, rollers and all other moving parts. While we had the car at chest level we cleaned the door operator limit contacts. I also changed the DO, T1, T2 relays in the controller. Ran and tested car with no issues. Left car in service. The electric safety edge is damaged on the bottom and is bypassing the bottom few infrared sensors, I recommend this safety edge be replaced. | TC-27097 | ||
| A-025 | AFW-90 | 1000 | Cars doors not closing fully on 4th floor preventing car from operating | 23/Mar/2021 | 24/Mar/2021 | N | 4 | Unit was found with the door closed. I operated the door and it worked fine but intermittently the car would not leave the fourth floor. Adjusted the door close limit switch and verified operation. Back in service. | TC-27219 | ||
| A-026 | AFW-90 | 1000 | Car became suck 5 feet below fourth floor trapping two employees. Fire department responded and shut down elevator | 13/Apr/2021 | |||||||
| A-027 | AFW-78 | 1000 | Elevator stuck on third floor and doors will not close | 14/Apr/2021 | 14/Apr/2021 | N | 3 | Verified the doors were deactivated. Found the problem was the fourth door stop switch was deactivated. Unsure why this occurred because you need a key to open the box but I reset switch and all was normal. Back in service | |||
| A-028 | AFW-98 | 1000 | West elevator is stuck on fourth floor and not responding | 14/Apr/2021 | 14/Apr/2021 | N | 5 | Troubleshoot the unit and had to call technical support. Found the rope grip tripped but the problem resetting it is that the terminal block in the board was not making good contact with the board. I had to jump the solder points in the board to get it working. Tested and found no issues. need to order DZ relay and a terminal block. Returned to service | |||
| A-029 | AFW-90 | 1000 | Car stuck on fourth deck | 28/Apr/2021 | 29/Apr/2021 | N | 9 | Unit was shutdown. Found governor linking pin out. Looked in hoistway and found it. Repaired and sealed the pin. Performed manual inspection speed governor test and unit passed. Returned to service |
within scope e (see # 71)
&"Times New Roman,Regular"PWS ATTACHMENT 5, Page &P of &N
Kone Service Calls
PWS ATTACHMENT 4 - NSWCPD ELEVATOR HISTORICAL SERVICE CALLS
| SERVICE CALL # | CAR # | BLDG # | DESCRIPTION | DATE | COMPLETION DATE | BEYOND SCOPE (Y/N) | ACTUAL LABOR HOURS | ACTUAL MAT'L COST | REPAIR | |
| E-001 | AFW-77 | 1000 | Car is stuck on 3rd deck. | 15-May-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-002 | AFW-78 | 1000 | Building occupant became stuck on 1st floor with doors partially open and car approximately 1' off ground floor. Car was traveling in the down direction. | 18-May-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-003 | AFW-88 | 1000 | Building occupant became stuck in the elevator just below the 2nd deck landing. The fire department had to rescue the individual from the top of the car. Please investigate and repair. | 26-Jun-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-004 | AFW-44 | 29 | Emergency bell does not work. Repair or replace. | 28-Jun-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-005 | AFW-78 | 1000 | Emergency elevator phone does not work. The car phone line was checked and is okay. | 28-Jun-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-006 | AFW-78 | 1000 | NW Freight Elevator was reported to be non-functioning by building occupants. Car was found ~1' above 1'st floor landing with doors open. Doors were closed and car appears to be functioning normally. Freight Elevator doors do not appear to be closing automatically (after set period of time). | 5-Jul-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-007 | AFW-1 | 77H | Bldg. 77H Freight Elevator (AFW-1), car is on the second floor with the doors open, doors will not close. | 25-Jul-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-008 | AFW-1 | 77H | Bldg. 77H Freight Elevator (AFW-1), car is on the second floor with the doors closed, doors will not open. | 30-Jul-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-009 | AFW-98 | 1000 | Person became trapped on the 2nd deck of AFW-98. Car was secured by NAVY Fire dept. and KONE installation team. Investigate and repair. | 7-Aug-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-010 | AFW-44 | 29 | Elevator car is on Mezz. Car has power and doors open/close but car will not respond to hall or floor calls. | 14-Aug-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-011 | AWW-98 | 1000 | Has been reported doors not fully closing on 1st deck and car is now out of service on 1st deck. | 16-Aug-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-012 | AFW-98 | 1000 | Has been reported doors not fully opening on multiple floors. | 20-Aug-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-013 | AFW-44 | 29 | Car was found on 2'nd deck. Doors open/close but car would not respond to hall or car calls. | 30-Aug-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-014 | AFW-92, AFW-93 | 4 | Both cars are responding to hall calls. Cars do not seem to be communicating. | 19-Sep-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-015 | AFW-78 | 1000 | Passenger became stuck in NW Freight elevator on 3rd floor. Passenger claims he closed doors but they did not fully close and the doors would not open or close. The car would also not travel since the doors weren't fully open. Passenger opened doors manually after 5 minutes. | 12-Oct-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-016 | AFW-77, AFW-78 | 1000 | Investigate and repair motor generators from running continuously. | 18-Nov-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-017 | AFW-77 | 1000 | The AFW-77 NE FREIGHT Car became stuck at the 2nd Floor Opening, about 8" above second deck landing. The doors are open, and will not close. NOTE: In the past, there have been reports of the car automatically stopping on 2nd Floor, regardless of floor selected. | 15-Nov-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-018 | AFW-96, AFW-97 | 633 | Investigate passenger elevator power parameters (460V vs 480V). Building power voltage is expected to be reduced to from 480V to 450V-460V. Please adjust elevator parameters to accept reduced voltage. | 20-Nov-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-019 | AFW-97 | 633 | AFW-97 landed 6" above the 3rd fl landing when using access switch. Access switch doesn't appear to be working properly, please investigate and repair. | 4-Dec-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-020 | AFW-99 | 1000 | AFW-99 - Emergency Bell does not work. Please investigate and repair. | 4-Dec-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-021 | AFW-96 | 633 | AFW-96 - Elevator is on second floor and does not respond to hall calls. | 4-Dec-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-022 | AFW-93 | 4 | AFW-93 - Elevator doors are making noise. Please check and address both passenger cars. | 17-Jan-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-023 | AFW-94 | 4 | AFW-94 - South Freight Elevator became stuck with occupants 18" above the 1st fl. landing. | 22-Jan-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-024 | AFW-98 | 1000 | AFW-98 - Investigate excessive brake dust on hoist machine. | 26-Feb-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-025 | AFW-44 | 29 | Elevator afw-44 is not responding to hall calls. | 30-Mar-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-026 | AFW-78, AFW-99 | 1000 | 1. AFW-78 NW Freight Elevator doors didn't close all the way, trapping occupant. | |||||||
| 2. AFW-99 East Passenger Elevator doors seem to be loose, clanging, making noises when they close and open. Is not a smooth door operation. | 18-Apr-2019 | Unknown | N | Unknown | Unknown | Unknown | ||||
| E-027 | AFW-94 | 4 | 1. AFW-94, key switch to enable elevator to access the attic (4'th floor) spins. | 24-Apr-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-028 | AFW-97 | 66 | 1. NAVY Police attempted to ride the car in the up direction when it came to an abrupt stop and the car took itself out of service. Passenger was able to finally get out by pressing the car buttons in which the doors finally opened back up on the first floor. The fire department responded and opened the disconnect. | 24-Apr-2018 | Unknown | N | Unknown | Unknown | Unknown | |
| E-029 | AFW-77 | 1000 | 1. Multiple passengers reported car was "bouncing" as it tired to level in to landing. Car was observed to vary speed in down direction between floors 4 and 3. | 10-May-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-030 | AFW-44 | 29 | 1. Bldg. 29 Pass. Elevator was stuck on 1'st floor with doors open. Light Curtain appears to be intermittent / problematic. | 14-May-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-031 | AFW-88 | 1000 | Bldg. 1000 East Passenger Elevator was taken out of service (opened disconnect) as car was | |||||||
| bouncing upon takeoff from the first floor landing. | 31-May-2019 | Unknown | N | Unknown | Unknown | Unknown | ||||
| E-032 | AFW-78 | 1000 | Bldg. 1000 NW Freight Elevator is stuck approx. 4' above the 1'st floor deck. The Navy Fire Dept. was able to open the doors and free the entrapped occupant. | 21-Jun-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-033 | AFW-78 | 1000 | Bldg. 1000 NW Freight Elevator gate has an intermittent closing issue. | 22-Jul-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-034 | AFW-90 | 1000 | Controller resistor wiring is melted. | 24-Jul-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-035 | AFW-1 | 77H | Freight Elevator Doors stop responding intermittently. Car has been reported to stop 1/2 way when traveling in upward direction. Car gate fails to fully raise. | 7-Aug-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-036 | AFW-92 | 4 | North Passenger Elevator: |
1. Car door makes noise while opening / closing
2. Several occupants complain about abrupt stop at landing while traveling in upward direction
| 3. In machine room, control valve makes prolonged buzzing noise during down leveling | 13-Aug-2019 | Unknown | N | Unknown | Unknown | Unknown | ||||
| E-037 | AFW-94 | 4 | Freight Elevator is not responding to hall calls. | 15-Aug-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-038 | AFW-78 | 1000 | Gate motor works intermittently. | 20-Aug-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-039 | AFW-92 | 4 | Check overall operation of elevator. Numerous bldg. occupants have been complaining of loud | |||||||
| intermittent noise coming the elevator. | 20-Aug-2019 | Unknown | N | Unknown | Unknown | Unknown | ||||
| E-040 | Unknown | N | Unknown | Unknown | Unknown | |||||
| E-041 | AFW-93 | 4 | AFW-93 is out of service on the 4th fl with doors open. | 18-Oct-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-042 | AFW-77 | 1000 | 1. Investigate car slowing down near second floor. |
2. Investigate door operation.
| 3. Investigate noise from motor and or generator. | 22-Oct-2019 | Unknown | N | Unknown | Unknown | Unknown | ||||
| E-043 | AFW-99 | 1000 | Investigate car stopped on first floor with doors open and not responding to calls (occurs intermittently). | 31-Oct-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-044 | AFW-96 | 633 | 1. Investigate battery lowering device. Power was secured and car did not seem to lower or open doors. | 4-Jan-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-045 | AFW-88 | 1000 | Investigate and repair elevator doors banging when opening. | 4-Nov-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-046 | AFW-90 | 1000 | Investigate and repair elevator door not closing (gate starts to close then stops and goes back up). | 8-Nov-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-047 | AFW-93, AFW-94 | 1000 | 1. Cars did not operate on emergency power. Cars received signal they were on emergency power as emergency power light was illuminated. |
2. Car emergency lights did not work (car went dark)
3. Car AFW-93 took itself out of service once power was returned to service due to motor starter fault.
4. AFW-92 went into alt. fire recall when main power was secured (disconnect opened) from
| AFW-93. | 12-Nov-2019 | Unknown | N | Unknown | Unknown | Unknown |
| E-048 | AFW-93 | 1000 | 1. Car briefly took itself out of service (in car position indicator read OS). Occupant was stranded |
in car for a few minutes while traveling to 4'th floor. Car resumed operation by itself, and
| occupant was able to get off on 4'th floor | 22-Nov-2019 | Unknown | N | Unknown | Unknown | Unknown | ||||
| E-049 | AFW-93 | 4 | Car briefly took itself out of service (in car position indicator read OS). Occupant was stranded in car for a few minutes while traveling to 4'th floor. Car resumed operation by itself, and occupant was able to get off on 4'th floor Appears to be problem with hoist way door closing and interlock. | 22-Nov-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-050 | AFW-97 | 633 | One of the cab lights is out. | 3-Dec-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-051 | AFW-1 | 77H | Car is stuck on 1st fl. | 13-Dec-2019 | Unknown | N | Unknown | Unknown | Unknown | |
| E-052 | AFW-99 | 1000 | Car is out of service on 2nd deck. | 15-Jan-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-053 | AFW-88 | 1000 | 1. Doors are opening rough/banging on every floor when opening/closing. | |||||||
| 2. There is a clicking noise (possibly bad roller) as the car travels up and down the hoist way. | 21-Jan-2020 | Unknown | N | Unknown | Unknown | Unknown | ||||
| E-054 | AFW-90 | 1000 | 1. Car is making a grinding noise as car travels up and down hoist way. Disconnect is open in MR. |
2. Ropes should be lubed.
| 3. Check brushes on motor and generator. | 23-Jan-2020 | Unknown | N | Unknown | Unknown | Unknown |
| E-055 | AFW-88 | 1000 | 1. Car hoist is leaking oil. |
2. Hoist oil is dirty and needs to be changed.
3. Ropes need to be lubed.
| 4. Check Brushes on Motor and Generator. | 23-Jan-2020 | Unknown | N | Unknown | Unknown | Unknown |
| E-056 | AFW-78 | 1000 | 1. Car hoist is leaking oil. |
2. Hoist oil is dirty and needs to be changed.
3. Ropes need to be lubed.
| 4. Check Brushes on Motor and DC Generator. | 23-Jan-2020 | Unknown | N | Unknown | Unknown | Unknown |
| E-057 | AFW-77 | 1000 | 1. Car hoist is leaking oil. |
2. Hoist oil is dirty and needs to be changed.
3. Ropes need to be lubed.
| 4. Check Brushes on Motor and DC Generator. | 23-Jan-2020 | Unknown | N | Unknown | Unknown | Unknown | ||||
| E-058 | AFW-1 | 77H | 1. Freight Doors not closing properly and then car will not travel to 2nd. deck. (Repeat Call) | 24-Jan-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-059 | AFW-99 | 1000 | Right (West) passenger Elevator is stuck on 1'st floor and not responding to calls. | 29-Jan-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-060 | AFW-94 | 4 | Bldg. 4 Freight Elevator 1'st floor doors are broken, leaving pit exposed when car leaves 1'st floor! Car was taken out of service. | 24-Jan-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-061 | AFW-78 | 1000 | Bldg. 1000 NW Freight Elevator is on the first floor, and will not respond to car calls. The doors open and close, however 1 person had become stuck in the car and claimed the doors would not open (the Navy Fire Dept. responded and removed the occupant from the elevator). Power was secured in the machine room to prevent occupants from attempting to use the car. | 29-Jan-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-062 | AFW-78 | 1000 | Bldg. 1000 NW Freight Elevator is on the first floor, and will not respond to car calls. The doors open and close. | 11-Feb-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-063 | AFW-90 | 1000 | Bldg. 1000 SE Freight Elevator, First floor hall doors are not opening properly (appears door is catching on 1 side) | 28-Feb-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-064 | AFW-90 | 1000 | Bldg. 1000 SE Freight Elevator, Car is on 1'st floor and will not respond to car or hall calls. | 3-Mar-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-065 | AFW-90 | 1000 | Bldg. 1000 SE Freight Elevator, 1'st floor hall door is not opening. | 5-Mar-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-066 | AFW-94 | 4 | Bldg. 4 Freight Elevator, car is on second floor, doors do not close. | 13-Mar-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-067 | AFW-88 | 1000 | 4th fl hall doors are open, car doors are closed. | 24-Mar-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-068 | AFW-88 | 1000 | 4th fl hall doors are open, car doors are closed. | 26-Mar-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-069 | AFW-88 | 1000 | 3'rd fl hall doors are open, car doors are closed. | 2-Mar-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-070 | AFW-88 | 1000 | 3'rd fl hall doors are stuck open. Car disconnect is open. | 23-Apr-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-071 | AFW-88 | 1000 | 3'rd fl hall doors are stuck open. | 20-May-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-072 | AFW-88 | 1000 | 3'rd fl hall doors are stuck open. | 26-May-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-073 | AFW-88 | 1000 | 1st fl. doors only opened approx. 2" when called. | 29-May-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-074 | AFW-1 | 77H | Car doors are not working. | 8-Jun-2020 | Unknown | N | Unknown | Unknown | Unknown | |
| E-075 | AFW-78 | 1000 | Car gate not operating on NW Freights | 25-Jun-2020 | Unknown | N | Unknown | Unknown | Unknown |
Non-Wear-and-Tear Repairs
PWS ATTACHMENT 4 - NSWCPD ELEVATOR HISTORICAL NON-WEAR-AND-TEAR REPAIRS
| SERVICE CALL # | CAR # | BLDG. # | DESCRIPTION | DATE | COMPLETION DATE | BEYOND SCOPE (Y/N) | Code 10211 Estimated Cost | ACTUAL LABOR HOURS | ACTUAL MAT'L COST | ACTUAL COST | REPAIR | |
| 2021-050 | 1000 | AFW-99 | Replace broken door lock restrictor on passenger elevator afw-99 | 19-Oct-2020 | Unknown | Y | Unknown | Unknown | Unknown | $2,060.77 | replace restricitor | |
| 2021-060 | 4 | AFW-92 | Replace damaged Janus Pana40 Plus 3-D Safety Door Sensor. Existing was damaged due to water | 11-Jan-2021 | Unknown | Y | $ 2,500 | Unknown | Unknown | $4,033.35 | Replace damaged parts from water damage | |
| 2021-061 | AFW-78 | 1000 | Gate sheave assembly damaged, needs to be replaced. Contractor also suggesting replacing motor and pinion. Contractor seems to think motor shaft could be bent. Recommend replacing sheave assembly, pinion, chains and proceeding without motor but have contractor check shaft for defects during repairs. If motor shaft is damaged, replace motor. | 2-Dec-2020 | Unknown | Y | $ 14,000 | 32 | $ 5,200 | $15,904.38 | replace gate motor and sheave assembly | |
| 2021-079 | AFW-97 | 633 | Perform repairs necessary to return Bldg. 633 West passenger elevator (AFW-97) to service. Currently elevator is Out Of Service due to doors not reliably closing. Most likely cause is a failing safety edge, however NSWC has not received the service call report or repair recommendation from NAVFAC or their Contractor. Please note this building is regularly occupied for multiple shifts, even during the | 3-Mar-2021 | Unknown | Y | $ 2,500 | 11 | $500 | $2,791.44 | replace door safety edge sensor | |
| 2021-093 | AFW-44 | 29 | Replace defective safety door edge on elevator doors. Replace in kind if possible | 11-May-2021 | Unknown | Y | $ 3,000 | 14 | $ 500.00 | $1,902.13 | replace door safety sensor | |
| 2021-094 | AFW-90 | 1000 | Bldg. 1000 Elevator weights sit on buffer when car is at the roof level landing. Car ropes need to be shortened enough to ideally allow the car to trip the top limit switch. At the very minimum, the ropes need to be adjusted to keep the weights off the buffers when the car is at the roof level landing. NAVFAC Elevator Inspector found this discrepancy and requested this work be completed. | 24-May-2021 | Unknown | Y | $ 6,000 | Unknown | Unknown | $6,546.70 | shorten cables | |
| 2021-097 | AFW-88, 96, 97 | 1000, 633 | Bldg. 1000 Passenger Elevator AFW-88 and Bldg. 633 Passenger Elevators AFW-96 & 97 were due for five year load test inspections. Elevator capacities are less than 10K lbs. | 27-May-2021 | Unknown | y | $ 6,000 | Unknown | Unknown | $5,763.33 | perform 5 year load tests | |
| 20-0070 | AFW-78 | 1000 | AFW 78 Emergency Repair - Master Limit and Prox Sensor | 31-Jul-2020 | Unknown | Y | Unknown | 8 | $ 396.72 | $3,261.92 | replace | |
| 2019-0047 | AFW-96 & AFW 97 | 633 | Modify Bldg. 633 Passenger elevators (AFW-96 & AFW-97) for proper operation with reduced supply voltage (450VAC vs 480VAC). | 21-Nov-2018 | Unknown | Y | $ 5,500 | Unknown | Unknown | Unknown | Unknown | |
| 2018-0089 | AFW-77 | 1000 | Repair NE freight elevator in Bldg. 1000 (AFW-77). Repair / replace faulty DC | |||||||||
| Motor-Generator set and test elevator once complete. | 29-May-2018 | Unknown | Y | $ 15,000 | Unknown | Unknown | Unknown | Unknown | ||||
| 2017-0025 | AFW-90 | 1000 | Replace freight doors and related components | 2-Dec-2016 | Unknown | Y | $ 125,000 | Unknown | Unknown | Unknown | Unknown | |
| 2016-0075 | AFW-77, AFW-78, AFW-1000 | 1000 | Install safety railings for each freight elevator in Bldg. 1000 (AFW-77, AFW-78, & |
AFW-1000). New safety railings must comply with ASME A.17.1 and UFGS code
| requirements. | 28-Jun-2016 | Unknown | Y | $ 18,000 | 88 | $ 2,200.00 | Unknown | Install 6ea - 8 foot sections and 6ea - 4 foot sections |
| 2015-0088 | AFW-78 | 1000 | Replace car & counter-weight channels and buffers and all associated supports/brackets |
and hardware. KTR to provide counter-weight buffers and channels at no cost to gov and pay for the labor to hoist car off the locks. 6-Aug-2015 Unknown Y $ 8,500 Unknown Unknown Unknown Unknown
A-026 AFW-90 1000 Car became suck 5 feet below fourth floor trapping two employees. Fire department responded and shut down elevator 13/Apr/2021 within scope e (see # 71)