Chiller and Boiler System Maintenance
Solicitation number
IFB FY27-086-03
Issued by
Maricopa County, Phoenix City, Arizona

About this file

This is a price sheet for an Invitation for Bid (IFB) issued by the City of Phoenix Housing Department for chiller and boiler system maintenance and repairs under solicitation number FY27-086-03. The price sheet outlines ten categories of required maintenance tasks spanning chiller and cooling tower operations, boiler and burner combustion systems, electrical and VFD cabinet maintenance, piping and water system inspections, operational testing and startup/shutdown procedures, gauges and documentation, oil system tasks, pumps and mechanical movement, structural inspections, and chemical system monitoring. Tasks are categorized by frequency of performance, including monthly, semi-annual, pre-season, and annual requirements, with corresponding quantities specified for each service line item. The contract term is five years from the commencement date with no options to extend.

The price sheet requires bidders to populate pricing for three service categories: Regular, Non-Standard, and Emergency rates across all 70 numbered line items plus ancillary charges for labor technician services (hourly rate), additional labor with approval (hourly rate), materials with a maximum markup of eight percent, and potential new chiller and boiler system installations. Bidders must also provide summary pricing organized by frequency of service (Annually, Pre-Season, Semi-Annual, and Monthly). The sheet includes provisions for hourly labor rates and material costs associated with emergency and additional repairs beyond the standard maintenance scope, allowing the City flexibility in addressing unexpected system failures and modifications throughout the five-year contract period.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Chiller & Boiler Price Sheet

Housing Department
Chiller and Boiler Maintenance & Repairs
IFB FY27-086-03
Company Name Below:
1. Chiller & Cooling Tower TasksQuantityRegularNon-StandardEmergency
1Brush chiller condenser tubes - Annually1
2Change filter in closed loop system - Monthly12
3Check chiller and condenser pumps - Monthly12
4Check chiller and water temperatures - Monthly12
5Check cooler tower – clean sump screens, check belts - Monthly12
6Check/clean cooling tower spray nozzles and hot water basins - Monthly12
7Check/clean pumps – chiller and condenser – switch lead pump - Monthly12
8Inspect oil and Freon levels - Monthly12
9Cycle and check the function and packing on all water control valves - Monthly12
10Test Buildings A and B third floor temps vs chiller room - Monthly12
11In wintertime, check comfort boiler - Monthly12
Subtotal for Chiller & Cooling Tower Tasks$0.00$0.00$0.00
2. Boiler/Burner Combustion System TasksQuantityRegularNon-StandardEmergency
Combustion Chamber & Burner Cleaning
12Clean and inspect boiler air filters - Annually1
13Clean and inspect burner section - Annually1
14Clean burner assemblies and ignition systems - Annually1
15Clean the combustion chamber coil per manufacturer specs (Boiler 300S-850A) - Annually1
16Inspect and clean burner using shop air (Boiler 300S-850A) - Annually1
Subtotal for Combustion Chamber & Burner Cleaning$0.00$0.00$0.00
Ignition & Flame Detection
17Check igniter. Clean and verify spark gap (Boiler 850) - Annually1
18Check flame sensor (Boiler 300S-850A) - Annually1
19Test flame failure detection system (Boiler 300S-850A) - Annually1
20Verify high/low fire flame signal compared to startup data (Boiler 850) - Annually1
21Check flame failure detection system components (Boiler 300A-850A) - Semi Annual2
Subtotal for Ignition & Flame Detection$0.00$0.00$0.00
Gas & Air Supply
22Check drip leg and gas strainers (Boiler 850) - Annually1
23Check air vents for leakage (Boiler 300A-850A) - Monthly12
24Test intake air pressure (Boiler 300A-850A) - Monthly12
25Replace filter(s) when intake air pressure increases by -0.5 in (Boiler 300A-850A) - Monthly12
Subtotal for Gas & Air Supply$0.00$0.00$0.00
Gas Pressures / Manifold / Firing Rate
26Check fan speed and manifold pressure (Boiler 850) - Annually1
27Check firing rate control vs manufacturer specs (Boiler 300A-850A) - Semi Annual2
28Test high and low gas pressure interlocks (Boiler 300A-850A) - Monthly12
Subtotal for Gas Pressures / Manifold / Firing Rate$0.00$0.00$0.00
Venting / Stack / Dampers
29Check flue, vent, stack, or dampers (Boiler 300A-850A) - Monthly12
30Visually inspect burner flames (Boiler 300A-850A) - Monthly12
31Visually inspect condensation drains & traps (Boiler 300A-850A) - Monthly12
32Visually inspect venting system for leakage/deterioration (Boiler 300A-850A) - Monthly12
Subtotal for Venting / Stack / Dampers$0.00$0.00$0.00
Safety Valves & Shutdown Devices
33Test safety/safety relief valves per ASME code (Boiler 850) - Annually1
34Recondition or replace low water cut-off device (Boiler 850) - Annually1
35Check valve core for 60 cycle hum/buzz + safety shut-off function (Boiler 300S-850A) - Annually1
36Perform leakage test on gas valves (Boiler 300S-850A) - Annually1
Subtotal for Safety Valves & Shutdown Devices$0.00$0.00$0.00
3. Electrical & VFD Cabinet Tasks - Required FrequencyQuantityRegularNon-StandardEmergency
37Tighten all electrical connections - Annually1
38Check and Clean VFD Cabinets - Pre-Season2
39Tighten all terminals, electrical and pipe connections - Pre-Season2
40Check condition of contactors and starters - Pre-Season2
41Inspect all electrical components for wear - Semi Annual2
42Inspect all safety switches - Semi Annual2
43Inspect all venting/make‑up/exhaust motors - Semi Annual2
Subtotal for Piping, Water, and System Leak Check$0.00$0.00$0.00
4. Piping, Water, and System Leak Checks - Required FrequencyQuantityRegularNon-StandardEmergency
44Inspect for water leaks - Semi Annual2
45Check for piping leaks around pumps, mixing valves, relief valves, fittings (Boiler 300A‑850A) - Monthly12
46Check water piping for corrosion or weakness - Monthly12
47Check expansion tank and closed loop system pressure - Monthly12
Subtotal for Piping, Water, and System Leak Checks$0.00$0.00$0.00
5. Operational Testing, Startup & Shutdown - Required FrequencyQuantityRegularNon-StandardEmergency
48Turn boiler on checking ignition & operation - Semi Annual2
49Chiller – annual inspection start up and shut down - Pre-Season2
50Heater boiler annual inspection start up and shut down - Pre-Season2
51Walk site supervisor through written start-up protocol - Pre-Season2
52General operational comments and recommendations - Pre-Season2
53Control operation - Pre-Season2
54Safety control operation - Pre-Season2
Subtotal for Operational Testing, Startup & Shutdown$0.00$0.00$0.00
6. Gauges, Recording, Documentation - Required FrequencyQuantityRegularNon-StandardEmergency
55Check and record alarms present/in history - Semi Annual2
56Record amp draws, pressures, temperatures - Semi Annual2
57Record model and serial numbers - Semi Annual2
58Record any repairs needed - Semi Annual2
59Fill out boiler tasking sheet for customer - Semi Annual2
60Recalibrate all indicating and recording gauges (Boiler 300A-850A) - Semi Annual2
Subtotal for Gauges, Recording, Documentation$0.00$0.00$0.00
7. Oil System Tasks - Required FrequencyQuantityRegularNon-StandardEmergency
61Oil filters - Pre-Season2
62Oil level - Pre-Season2
63Oil replaced / type and amount - Pre-Season2
64Oil sample - Pre-Season2
Subtotal for Oil System Tasks - Required Frequency$0.00$0.00$0.00
8. Pumps & Mechanical Movement - Required FrequencyQuantityRegularNon-StandardEmergency
65Inspect booster pumps for bearing wear/leakage - Semi Annual2
66Inspect pumps (SA) - Semi Annual2
Subtotal for Pumps & Mechanical Movement$0.00$0.00$0.00
9. Structural / Physical Inspection - Required FrequencyQuantityRegularNon-StandardEmergency
67Inspect insulated panels for cracks/broken pieces - Annually1
68Inspect heat exchanger for cracks - Annually1
Subtotal for Structural / Physical Inspection$0.00$0.00$0.00
10. Chemical & System Monitoring - Required FrequencyQuantityRegularNon-StandardEmergency
69Chemical testing: hardness, alkalinity, chlorides, nitrite, phosphates, pH, conductivity, biological activity - Monthly12
70Maintain chemical feed systems, scale/corrosion control, biocides, and water‑use tracking. - Monthly12
71Provide monthly monitoring data in reports for chemicals - Monthly12
Subtotal for Chemical & System Monitoring$0.00$0.00$0.00
Grand total for All Services$0.00$0.00$0.00
11. Ancillary Charges for additional Repairs - Unit of MeasureQuantityRegularNon-StandardEmergency
72Labor Technician - Hourly1
73Additional Labor with approval - Hourly1
74Materials - Markup % (No greater then 8%)1
75New Chiller System1
76New Boiler System1
AnnuallyPre-SeasonSemi AnnualMonthly