PN96540_DESIGN COMPLETE_DWG_Part7.pdf

PDF 7 MB Posted

Attached to
FY22 Military Construction Army (MCA) 096540 Child Development Center, Aliamanu Military Reservation, Oahu, Hawaii
Solicitation number
W9128A22R0019
Issued by

About this file

This is a solicitation for a design-bid-build construction project. The U.S. Army Corps of Engineers, Honolulu District is seeking proposals to construct a Child Development Center at Aliamanu Military Reservation, Oahu, Hawaii for approximately $50-100 million. The project includes a large standard-design Child Development Center to serve children ages six weeks to five years with outdoor play areas, as well as supporting facilities such as utilities, parking, and landscaping. Work will also involve installing security, alarm, and intercom systems. Proposals are due by July 29, 2022 and will be evaluated on experience, past performance, technical approach, and price using lowest price technically acceptable procedures. The contract will be a firm fixed-price award with a performance period of 1,048 calendar days from notice to proceed. Small businesses are encouraged to submit subcontracting plans.

View the file

Other files

Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

G G

TRANSFORMER WIDTH (A)

TR

AN

SF

O

R M

ER

H

EI

G

H T

(C

12" 12"12"

12"

12"

3"

2" 2"

" 10

STENCILED WARNING

SIGN (REFLECTIVE PAINT

YELLOW) SEE NOTE 3

STENCILED KVA

RATING (REFLECTIVE

PAINT YELLOW)

COOLING FINS

(RADIATOR)

IF EQUIPPED

STENCILED PHASE

RATING (REFLECTIVE

PAINT YELLOW)

#4 @ 12"

T.& B. EACH WAY

DANGER

HIGH VOLTAGE

KEEP OUT

M

IN

PADLOCKABLE

HANDLE

COOLING FINS

(RADIATOR)

IF EQUIPPED

AGGREGATE

BASE COURSE

6"

G G

G G

G G

G G

G G

C O

N C

R

ET

E

PA

D L

EN

G

TH

CONCRETE PAD WIDTH

TRANSFORMER WIDTH

CONCRETE PAD

TR

AN

SF

O

R M

ER

D

EP

TH

12"12"

24" 24"

3"

3"3"

6" 6"

2"2"

"B"

"A"

"B"

"A"

GROUND ROD,

CU CLAD STL,

3/4" x 10' LG

(TYP)

GRAVEL FILL ALL

AROUND CONCRETE

PAD

CONCRETE PAD

OPENING FOR

CABLE ENTRANCE

SECONDARY

COMPARTMENT

PRIMARY

COMPARTMENT

TRANSFORMER

TANK

COOLING FINS

(RADIATOR)

IF EQUIPPED

TAP CHANGER

X1 X3

X0 X2

G

G

G

N

OIL FILL PLUG

DRAIN PLUG

GROUND PAD

CONCRETE PAD OPENING

FOR CABLE ENTRANCE

N

G

G G

N

N

G G

SURGE ARRESTER

(TYP)

PARKING BRACKET (TYP)

1/2" PEJ

W/SEALANT

#2 AWG BARE CU

GND WIRE FOR CABLE

SHIELD GROUNDING

BONDING JUMPER

SAME WIRE SIZE

AS NEUTRAL

BAY-O-NET CURRENT

LIMITING FUSES HOLDERS

GROUNDING CONDUCTOR

BARE CU, SIZE BASED

LOOP FEED

SWITCH, SEE SPEC

6" THICK 12" WIDE

CONC W/ 1/4" x 1/4" WWF

ALL AROUND

M

IN

SAFE BREAK

BUSHING (TYP)

SPADE TYPE

BUSHINGS (TYP)

PRESSURE

RELIEF DEVICE

OIL LEVEL

INDICATOR

TRANSFORMER

NAME PLATE

ON XFMR CAPACITY

#4/0 AWG

MIN. BC (TYP)

AGGREGATE

BASE COURSE

6"

G

G G G

TRANSFORMER DEPTH

TR

AN

SF

O

R M

ER

H

EI

G

H T

N

12"

12"

3"

6" 6"

GROUNDING

CONDUCTOR,

BARE CU, SIZE

BASED ON XFMR

CAPACITY

GROUND ROD,

CU CLAD STL,

3/4" x 10'

LG (TYP)

COOLING FINS

(RADIATOR)

IF EQUIPPED

CONC PAD

OPENING

FOR CABLE

ENTRANCE

NOTES:

1. THREE PHASE TRANSFORMER SHALL BE RATED 12.47 KV

(DELTA) PRIMARY - 480Y/277 V (WYE) SECONDARY.

2. DETAILS OF THE WARNING SIGN SHALL BE IAW IEEE STD.

3. INDICATED DIMENSIONS OF TRANSFORMER ARE APPROXIMATE.

USE ACTUAL DIMENSIONS OF MANUFACTURER'S DRAWING FOR

CONSTRUCTION.

4. EARTH RESISTANCE SHALL NOT EXCEED 5 OHMS.

5. PROVIDE DATE OF INSTALLATION ON THE EQUIPMENT TO BE

PAINTED IN THE ENCLOSURES.

6. FINISH COLOR FOR OUTDOOR CABINET SHALL BE NORWOOD

BROWN, #10045 PER DPW EXTERIOR STANDARDS.

7. PROVIDE 15 KV INSULATED PARKING BUSHING W/ INSULATED

PROTECTIVE CAP ON ALL PARKING STANDS.

8. UPON COMPLETION OF EQUIPMENT INSTALLATION, THE

CONCRETE PAD CABLE OPENING SHALL BE FILLED W/ MASONRY

GROUT PER SPEC SECTION 33 71 02.

9. SEAL SPARE CONDUITS. DUCT SEAL CONDUITS WITH CABLES.

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EP501

PA

D

M O

U N

TE

D

T R

AN

SF

O R

M

ER

D

ET

AI

LS

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

NTSD1 TRANSFORMER DETAIL (FRONT ELEVATION)

NTSA1 TRANSFORMER PAD DETAIL

NTSD5 TRANSFORMER SECTION A-A

NTSA5 TRANSFORMER SECTION B-B

4-PIECE REMOVABLE

CONC SLABS

#4 BARS @ 8" ON CENTER

4#3 STL BARS

2#3 STL BARS

SPACER BAR

1/2" x 1/8" x 1"

1/4" ROUNDED

CORNER (TYP)

DRILL & TAP FOR 3/4"

U.S. STD. THREAD

3/4" BRASS PLUG W/ SLOT,

APPLY GREASE TO THREADS

TOP OF REMOVABLE

CONC SLAB

1-3/8"Ø x 2-15/16"

STEEL ROD FROM

ROUND STOCK

WELD ALL AROUND

TO FRAME

TIE TO REBARS IN WALL

INSTALL AT L OF

WALL, TYPICAL

TIE TO REBARS

IN WALL

7/8" DIAMETER

GALVANIZED

PULLING-IN ROD

CONC FILL

15" [ 33.9 FRAME

4#4 STL BARS

WELD TO FRAME

2#3 STL. BARS

2-LIFTING DEVICES

SPACER BAR

SPACER BAR

1/2" x 1/8" x 1"

6"

9"

8-3/8"

C

NOTES:

1. PROVIDE 2 EACH COVER LIFTING TOOL FOR HANDHOLE.

2. GLAVANIZE L OR C FRAME, STEEL RODS, AND SPACER BAR ASSEMBLIES AFTER FABRICATION.

x x x

1/8"

COVER SLAB SECTION

COVER SLAB PLAN

EL

EC

ELEC

PLAN

SECTION B-BSECTION A-A

2"

3" 3"2'-10 3/4"

3'-4 3/4"

1/

2"

1/ 2"

1' -3

6 5/8" 1'-3" 1'-3" 1'-3"

2"

1'-3" 6 5/8"

6'-2"

7"

3/16" 1/8" 1/8" 1/8"

3/16"

7" 3'

-0

7" 7"5'-0"

1/ 8"

1/

2"

1/ 8"

1/

2" 3'

-5

4' -2

SLOPE FLOOR DRAIN 1/2" TO SUMP

7" 1'-0" 7"4'-0"

" M

IN

6"

4"

1/ 2"

6"

4' -0

3/8"

6" 6"

1/ 2"

4' -0

2-1/2"

7"2'-0"1'-0"7"

1'-0 1/4" 1'-0 1/4" 1'-0 1/4" 2" 2"

1"

3- 3/

8"

1/2"

1"

1- 1/

4"

1- 1/

8"

2"

3"

1- 1/

2"

6"

LIFTING DEVICE

EMBOSSED (OR ENGRAVED)

MARKING, 2" HIGH

LETTERING, MINIMUM

FINISHED GRADE

OR PAVEMENT

#4 BARS @ 8" ON CENTER

#4 BARS @ 10" ON CENTER

CONCRETE WALLS

SHALL BE STRENGTH

TESTED TO 3,000 PSI

(TYP)

3/4"Ø x 10'-0" SECTIONAL COPPER

CLAD GROUND ROD WITH CLAMP

#4 BARS @ 10" ON CENTER

12" x 12" x 12"D

SUMP HOLE

PULLING-IN IRON,

SEE DETAIL A8

4-PIECE REMOVABLE

CONC SLABS

#4 BARS @ 10" ON CENTER

DUCT ENTRANCE,

SEE SHEET ES501

PULLING-IN IRON,

SEE DETAIL A8

CONCRETE WALLS

SHALL BE STRENGTH

TESTED TO 3,000 PSI.

(TYP)

3/4"Ø x 10'-0" SECTIONAL

COPPER CLAD GROUND

ROD WITH CLAMP

12" x 12" x 12"D

SUMP HOLE

#4 BARS @ 10"

ON CENTER

FINISHED GRADE

OR PAVEMENT

B

AA

B

CABLE RACK. TYP EACH END

SEE SPEC 26 20 00

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EP502

EL

EC

TR

IC

AL

H

H

'x6 ' D

ET

AI

L

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

A1 TYPICAL 4' X 6' HANDHOLE

NOT TO SCALE A8 PULLING IRON DETAIL

NOT TO SCALE

D8 LIFTING DEVICE DETAIL

NOT TO SCALE

F8 SPACER BAR DETAIL

NOT TO SCALE

3" CONDUIT UON

ON PLANS

8" CONC. SECTION

GROUND ALL METAL

HH COMPONENTS

COMPACTED GRAVEL

SUBBASE 6"

GROUND ROD

BRICK UNDERLAY, NUMBER OF

COURSES AS REQUIRED TO

ACCOMODATE CONDUIT ENTRY AT

MINIMUM CONDUIT DEPTH

SEE DETAIL A4

FINISH GRADE

NOTES:

1. ENSURE HANDHOLE IS TRAFFIC RATED H-20.

EP503

D1

EP503

F1

AUTOMATIC

TRANSFER

SWITCH

(ATS)

2"x2" GALV STEEL ANGLE FRAMING

2"x2" GALV

SLOTTED "U"

CHANNEL, TYP

EXPLOSION-PROOF

SEAL, PROVIDE ONLY

FOR CONDUITS FOR

LIFT STATION

3/8" DIA GALV CARRIAGE

BOLT, NUT AND WASHER

2"x1-1/2" GALV STEEL ANGLE

SUPPORT BRACE, TYP

GROUND

LEVEL

1'

0"

TY

P

1' - 0", TYPCOMBINATION

COUPLING

1.5" PVC,

CONCRETE

ENCASED

GROUNDING ROD

NOTES:

1. DIMENSIONS ARE TYPICAL. ADJUST AS REQUIRED TO ACCOMODATE ELECTRICAL EQUIPMENT.

SEWER

PUMP LIFT

STATION

CONTROL

PANEL

(3) 1.5" PVC,

CONCRETE

ENCASED

5' - 6"

5'

9"

1.5" GRS

1' - 9" 3' - 0"

4'

0"

1.5" GRS

1-#6 GND

SASSAFRAS DRIVENEW CHILD

DEVELOPMENT

CENTER

3"

9"

3"

7/8" DIA

/8

2#3 LONGITUNDINAL

4#3 TRANSVERSE

1/8" FRAME2" X 2" X

2' - 0"

1' -0

6"

2#4 ALL AROUND (TYP)

3' - 0"

2' - 0"

3' - 0"

8"

2"

F1

EP503

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EP503

EL

EC

TR

IC

AL

H

AN

D

H O

LE

L

IF

T

ST

AT

IO

N

PE

D

ES

TA

L

D

ET

AI

LS

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

NOT TO SCALEA1 HANDHOLE ELEVATION DETAIL

NOT TO SCALEA7 SEWER PUMP LIFT STATION EQUIPMENT PEDESTAL DETAIL

NOT TO SCALED1 HANDHOLE PULLING IRON DETAIL

NOT TO SCALEF1 HANDHOLE COVER DETAIL

NOT TO SCALEA4 HANDHOLE COVER DETAIL - ISOMETRIC

CONDUIT

3A

3B SEALANT

3B 3A 3B

3A

NOTE:

SECTION A-A

(WALL ASSEMBLY)

SECTION A-A

(FLOOR ASSEMBLY)

A

FLOOR OR WALL

ASSEMBLY

PACKING

MATERIAL

FIRESTOP RATING

SHALL BE EQUAL TO OR GREATER THAN

FLOOR OR WALL RATING, FOR EXAMPLE:

3 HOURS FOR A 3 HOUR RATED FLOOR.

A

RIGID METAL CONDUIT

STUBOUT, +4" AFF

CONC ENCASE

TRANSITION

CONC ENCASED

TYPE PVC CONDUIT

TYPE PVC TO RIGID METAL

CONDUIT ADAPTER

CONC EQUIPMENT

PAD

FINISHED FLOOR

SWITCHBOARD OR MAIN DISTRIBUTION PANEL

2 3/4"

69 1/2"

5/

8"

5/ 8"

2 3/4"

/2

/2

/2

/4

12 3/8" 8 1/4" 8 1/4" 20 5/8"

75" ANCHOR BOLT,

(TYP)

CONDUIT STUBOUT

APPROX. LOCATION

(TYP) DOOR OPENINGS,

38" (TYP)

COMPARTMENT-1COMPARTMENT-2

COMPARTMENT-4COMPARTMENT-3

/2

6" 6"

75"

72 3/4"

75 3/4"

1 1/2" 1 1/2"

/2

FRONT

SIDE

COMPARTMENT-1COMPARTMENT-2

COMPARTMENT-4COMPARTMENT-3

6" 6"

6" 6"

SWITCH WIDTH

SW

IT

C H

D

EP

TH

CONC PAD WIDTH

C O

N C

P

AD

L

EN

G

TH

12" 12"

G G

G G

G

G

G

G

CONC PAD OPENING

FOR CABLE ENTRANCE

(TYP)

CONC PAD

GROUND ROD,

COPPER CLAD STEEL,

3/4"X10'-0" (TYP)

24" 24"

#3/0 AWG

MIN. BC (TYP)

BURIED MIN

24"

BELOW

GRADE

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EP504

PA

D

M O

U N

TE

D

S W

IT

C

H D

ET

AI

LS

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

NOT TO SCALEA1 PENETRATION FIRESTOPPING DETAIL

NOT TO SCALEA7 SERVICE ENTRANCE TRANSITION DETAIL

NOT TO SCALED1 4-WAY PAD MTD SWITCH DETAIL - PLAN

NOT TO SCALED4 4-WAY PAD MTD SWITCH DETAIL - ELEVATION

NOT TO SCALED7 4-WAY PAD MTD SWITCH DETAIL - CONCRETE PAD

3' - 6"

5'

6"

ELECTRICAL

DISCONNECT

2"x2" GALV STEEL ANGLE FRAMING2"x2" GALV

SLOTTED "U"

CHANNEL, TYP

3/8" DIA GALV CARRIAGE

BOLT, NUT AND WASHER

2"x1-1/2" GALV STEEL ANGLE

SUPPORT BRACE, TYP

GROUND

LEVEL

1'

0"

TY

P

1' - 0", TYP

COMBINATION

COUPLING

2" PVC, CONCRETE

ENCASED

GROUNDING ROD

NOTES:

1. DIMENSIONS ARE TYPICAL. ADJUST AS REQUIRED TO ACCOMODATE ELECTRICAL EQUIPMENT.

2" GRS FINISHED GRADE

RIGID STEEL CONDUIT

PVC CONDUIT

ENCASED IN

CONCRETE

PVC TO STEEL

ADAPTER

WALL

3" OR LESS 4"

3' - 6"

5'

6"

MOUNTING BOX FOR

TEMP CONNECTION

2"x2" GALV STEEL ANGLE FRAMING 2"x2" GALV

SLOTTED "U"

CHANNEL, TYP

3/8" DIA GALV CARRIAGE

BOLT, NUT AND WASHER

2"x1-1/2" GALV STEEL ANGLE

SUPPORT BRACE, TYP

GROUND

LEVEL

1'

0"

TY

P

1' - 0", TYP

COMBINATION

COUPLING

4" PVC, CONCRETE

ENCASED

GROUNDING ROD

NOTES:

1. DIMENSIONS ARE TYPICAL. ADJUST AS REQUIRED TO ACCOMODATE ELECTRICAL EQUIPMENT.

2. SIZE MOUNTING BOX ACCORDING TO MANUFACTURER RECOMMENDATION FOR TEMP CONNECTIONS

4" GRS

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EP505

D

IS

C O

N N

EC

T

ST

AN

D D

ET

AI

L

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

NOT TO SCALEA1 DISCONNECT STAND DETAIL

1/2" = 1'-0"A6 PVC TO STEEL CONDUIT CONVERSION

NOT TO SCALEC6 TEMP CONNECTION STAND DETAIL

LOW VOLTAGE

STUB-UP AREA

SURFACE MOUNTED

MOUNTING HOLES

24" 24"

D

EP

TH

C O

N C

P

AD

L

EN

G

TH

#8 AWG MIN.

BC (TYP)

BURIED MIN

24" BELOW

GRADE

CONC PAD

G G

G

G

G G

G

G

O

PE

N A

R

EA

8.

1"

.1

O

PE

N A

R

EA

8.

1"

LOW VOLTAGE

STUB-UP AREA

BASETANK MOUNTED

(NOTE 3)

PRIMARY CB

CONNECTION BOX

OPENING

PRIMARY HIGH VOLTAGE

STUB-UP AREA W/ GLAND

PLATE

FO

R

S

TU

B- U

P

FO

R S

TU

B-

U P

76"

67.3"

22.4"

33.7"

44.9"

10"

OPEN AREA

12.2"

FOR STUB-UP

12.2" 17.3"

GROUND ROD,

COPPER CLAD STEEL,

3/4" x 10'-0" (TYP)

12" 12"

.5

38" 76"

94.8"

FRONT VIEW SIDE VIEW

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EP506

D

IE

SE

L

G

EN

ER

AT

O R

D

ET

AI

L

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

K.

C

H O

Y

M

AY

DESIGN COMPLETE

1 1/2" = 1'-0"A1 DIESEL GENERATOR PLAN VIEW - CONCRETE PAD

GENERAL NOTES:

1. COORDINATE FINAL STUB UP LOCATIONS FOR GENERATOR WITH MANUFACTURER/

SELECTED EQUIPMENT.

2. GENERATOR SHALL HAVE A UL 142, DOUBLE WALL, FUEL BASE TANK.

3. DPW ENVIRONMENTAL DIVISION HAS REQUESTED TO BE NOTIFIED PRIOR TO

GENERATOR STARTUP. THEY WOULD LIKE TO CONDUCT A SITE VISIT DURING

STARTUP.

1 1/2" = 1'-0"E1 DIESEL GENERATOR DETAIL ELEVATION

N C

A

A2 A1

A

B2 B1

B

C2 C1

C

N C

3P

A

N C

N C

A

A

A

SWITCHING STATION #2

A

B

C

C

B

A

1 4

2 3

A

B

C

C

B

A

EXST EMH "B"

EXST PRIMARY

ELECTRIC HANDHOLE

TO XFMR T-03

EXST HANDHOLE "C"

EXST EMH (NO LABEL) EXST EMH #8

EXST EMH #9

EXST EMH #1

EXST 4-WAY PAD MTD

PRIMARY SWITCH SW-01

FOR FUTURE USE

EXST EMH "A"

EXST EMH "A"

EXST 2-#2 IN 4"C

EXST 3-#2 IN 4"C

EXST 1-#2 IN 4"C

EXST 1-#2 IN 4"C

N C

A2 A1

A

B2 B1

B

C2 C1

C

N C

3P

A

N C

N C

A

A

A

SWITCHING STATION #2

A

B

C

C

B

A

1 4

2 3

A

B

C

C

B

A

A

B

C

C

B

A

1 4

2 3

A

B

C

C

B

A

EXST EMH "B"

EXST PRIMARY

ELECTRIC HANDHOLE

TO XFMR T-03

EXST HANDHOLE "C"

EXST EMH (NO LABEL) EXST EMH #8

EXST EMH #9

EXST EMH #1

EXST 4-WAY PAD MTD

PRIMARY SWITCH SW-01

FOR FUTURE USE

NEW EMH #10

CONTINUED ON

SHEET EP602/D1

NEW 2-#2 IN EXST 4"C

NEW 3-#2 IN 4"C

NEW 3-#2 IN 4"C

NEW 3-#250 KCMIL IN 5"C

NEW 4-WAY PAD MTD

PRIMARY SWITCH SW-04

EXST EMH "A"

EXST EMH "A"

X X X

X

X

X

X X X X X X X X X

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EP601

O N

E

LI

N E

D

IA

G R

AM

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

NOT TO SCALED1 EXISTING ONE LINE DIAGRAM

NOT TO SCALEA1 ONE LINE DIAGRAM - 1

CONTINUED ON

SHEET EP601/C8

SA

3P30A

3P300A

3P300A

3P1000A

3P100A

3P100A

3P125A

3P100A

3P100A

3P100A

3P100A

3P100A

3P1000A

3P1200A

3P30A

SPD

WHM

NEW METER

NEW CT CAB

42"x42"x11"

1 KWH

KWH

E

PANEL MDP

1200A BUS, 3P, 4W, 480/277V, 65kAIC

LOCATION ELECTRICAL ROOM 301

SEWER PUMP LIFT STATION

DOUBLE THROW

SWITCH, 400A, 3PH,

4W, NEMA 4X ENCL

1.5"C, 3#4, #10G

4"C, 4#500 KCMIL,

#2G

4"C, 4#500 KCMIL,

#2G

(3) 5"C, 4#500 KCMIL, #3/0G

PAD MOUNTED UTILITY TRANSFORMER

1000kVA, 12.47kV-480/277 Z=5.75% MIN

125E

1-#4/0 GND

5"C, 3#250 KCMIL AND

ADDL 5"C SPARE

3P300A

PANEL MH

480Y/277V, 3PH, 4W

XFMR DPT

480-208Y/120V, 3PH, 4W, 500kVA

(3) 5"C, 4#500 KCMIL, #3/0G

2"C, 4#1, #8G

SPD

2"C, 4#1, #8G

2"C, 4#1/0, #8G

2"C, 4#2/0, #6G

2"C, 4#2/0, #6G

2"C, 4#2/0, #6G

2"C, 4#2/0, #6G

3P100ASPD

3P125A

3P100A

3P100A

3P100A

3P100A

PANEL C1

208Y/120V, 3PH, 4W

PANEL FPL

208Y/120V, 3PH, 4W

PANEL GL1

208Y/120V, 3PH, 4W

PANEL GL2

208Y/120V, 3PH, 4W

PANEL GL3

208Y/120V, 3PH, 4W

PANEL LL

208Y/120V, 3PH, 4W

PANEL ML2

208Y/120V, 3PH, 4W

PANEL DP208

208Y/120V, 3PH, 4W

LOCATION: ELECTRIC ROOM 308

N

GND

1-#3/0 GND 1"C, 3#8, #8G

(4) #5C, 4#500 KCMIL, #3/0G

G

25KW DIESEL

GENERATOR

480/277V, 3PH

(WEATHERPROOF)

1.5"C, 3#4, #10G

30A AUTOMATIC

TRANSFER

SWITCH,

NEMA 4X,304/304L

1.5"C, 3#4, #10G

KWH

3P100A 2"C, 4#2/0, #6G

3P100A

PANEL GL4

208Y/120V, 3PH, 4W

2"C, 4#2/0, #8G 3P100A

PANEL ML

208Y/120V, 3PH, 4W

3P250A

3"C, 4#350 KCMIL, #4G

3P250A

PANEL KEP

208Y/120V, 3PH, 4W

3P125A

E CHILLER (CH-1)

DISCONNECT,

400A, 3PH, 4W

NEMA 4X ENCL

4"C, 4#500 KCMIL, #2G

480/277V, 3PH, 4W, 400A

TEMP CHILLER

CONNECTION, SEE

EP106/A1

4"C, 4#500 KCMIL, #2G

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EP602

O N

E

LI

N E

D

IA

G R

AM

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

NOT TO SCALEA1 ONE LINE DIAGRAM - 2

KEYNOTES:

PROVIDE ADVANCED METER PER DPW METER STANDARDS AND AS REQUIRED PER: ECB 2015-2, UFC 1-200-02 (HIGH PERFORMANCE & SUSTAINABLE BLDGS REQTS), UFC 3-470-01 (12TH JAN 2018 REV)

AND UMSC/MCX GUIDELINES FOR ADVANCED METERING. CT 2000-5.

PROVIDE LOCK ON BREAKER AND PAINT BREAKER RED.

IN ADDITION TO THE PANELNAME PLATE, A LABEL INSCRIBED AS "FIRE PROTECTION/LIFE SAFETY EQUIPMENT SHALL BE CONSTRUCTED AND FASTENED TO THE SERVICE ENTRANCE EQUIPMENT. THE

LABEL SHALL BE RED LAMINATED PLASTIC WITH WHITE CENTER CORE.

CONNECT METER TO NEARBY DDC PANEL TO ALLOW LOCAL AND REMOTE READINGS.

MOUNTING BOX (RATED FOR OUTDOOR) FOR TEMP CONNECTION

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EP611

PA

N

EL

S

C H

ED

U

LE

S

-1

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EP612

PA

N

EL

S

C H

ED

U

LE

S

-2

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EP613

PA

N

EL

S

C H

ED

U

LE

S

-3

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EP614

PA

N

EL

S

C H

ED

U

LE

S

-4

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

CAMERA LABEL LOCATION CAMERA LABEL LOCATION

C-1 005 RECEPTION C-50 106 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM

C-2 014 CORRIDOR C-51 106 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM

C-3 014 CORRIDOR C-52 106 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM

C-4 014 CORRIDOR C-53 107 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM

C-5 001 VESTIBULE C-54 107 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM

C-6 014 RECEPTION CORRIDOR C-55 107 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM

C-7 014 CORRIDOR C-56 108 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM

C-8 NOT USED C-57 108 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM

C-9 014 CORRIDOR C-58 108 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM

C-10 014 CORRIDOR C-59 109 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM

C-11 ROOM 008 C-60 109 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM

C-12 ROOM 008 C-61 109 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM

C-13 014 CORRIDOR C-62 009 ACTIVITY PLAY ROOM

C-14 014 CORRIDOR C-63 10 ACTIVITY PLAY ROOM

C-15 014 CORRIDOR C-64 11 ACTIVITY PLAY ROOM

C-16 NOT USED C-65 NOT USED

C-17 014 CORRIDOR C-66 201 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-18 014 CORRIDOR C-67 201 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-19 014 CORRIDOR C-68 202 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-20 014 CORRIDOR C-69 202 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-21 BLDG EXTERIOR EAST C-70 203 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-22 BLDG EXTERIOR EAST C-71 203 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-23 BLDG EXTERIOR SOUTH C-72 204 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-24 BLDG EXTERIOR SOUTH C-73 204 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-25 BLDG EXTERIOR SOUTH C-74 205 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-26 BLDG EXTERIOR SOUTH C-75 205 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-27 BLDG EXTERIOR SOUTH C-76 206 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-28 014 CORRIDOR C-77 206 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-29 014 CORRIDOR C-78 207 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-30 014 CORRIDOR C-79 207 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-31 NOT USED C-80 208 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-32 012 OUTREACH/TRANSITIONAL CARE ACTIVITY ROOM C-81 208 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-33 012 OUTREACH/TRANSITIONAL CARE ACTIVITY ROOM C-82 209 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-34 012 OUTREACH/TRANSITIONAL CARE ACTIVITY ROOM C-83 209 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-35 101 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-84 210 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-36 101 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-85 210 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-37 101 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-86 211 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-38 102 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-87 211 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-39 102 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-88 212 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-40 102 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-89 212 INFANT/PRE-TOD/TODDLER ACTIVITY ROOM

C-41 103 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-90 005B ISOLATION AREA

C-42 103 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-91 BLDG EXTERIOR SOUTH

C-43 103 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-92 BLDG EXTERIOR SOUTH

C-44 104 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-93 BLDG EXTERIOR SOUTH

C-45 104 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-94 BLDG EXTERIOR WEST

C-46 104 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-95 BLDG EXTERIOR WEST

C-47 105 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-96 PRE-KINDERGARTEN PLAYGROUND

C-48 105 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-97 PRE-KINDERGARTEN PLAYGROUND

C-49 105 PRESCHOOL/PRE-K/KINDERGARTEN ACTIVITY ROOM C-98 PRE-KINDERGARTEN PLAYGROUND

CAMERA LABEL LOCATION

C-99 NOT USED

C-100 PRE-KINDERGARTEN PLAYGROUND

C-101 PRE-KINDERGARTEN PLAYGROUND

C-102 PRE-KINDERGARTEN PLAYGROUND

C-103 PRE-KINDERGARTEN PLAYGROUND

C-104 PRE-KINDERGARTEN PLAYGROUND

C-105 PRE-KINDERGARTEN PLAYGROUND

C-106 BLDG EXTERIOR NORTH

C-107 BLDG EXTERIOR NORTH

C-108 BLDG EXTERIOR TODDLER PLAYGROUND

C-109 BLDG EXTERIOR TODDLER PLAYGROUND

C-110 BLDG EXTERIOR TODDLER PLAYGROUND

C-111 BLDG EXTERIOR TODDLER PLAYGROUND

C-112 BLDG EXTERIOR TODDLER PLAYGROUND

C-113 BLDG EXTERIOR TODDLER PLAYGROUND

C-114 BLDG EXTERIOR TODDLER PLAYGROUND

C-115 BLDG EXTERIOR TODDLER PLAYGROUND

C-116 BLDG EXTERIOR TODDLER PLAYGROUND

C-117 BLDG EXTERIOR TODDLER PLAYGROUND

C-118 BLDG EXTERIOR TODDLER PLAYGROUND

SUPPLEMENTAL SPECIAL SYSTEMS LEGEND:

J

IMS INTERCOM MASTER STATION. SEE EY501/F1

GENERAL SPECIAL SYSTEMS NOTES:

(APPLICABLE TO ALL EY SHEETS)

JUNCTION BOX FOR GFGI CCTV. MOUNTED 7'-10'' AFF/AFG, UON, SEE SHEET

EY502.

WALL-MOUNTED JUNCTION BOX. REFER TO ASSOCIATED NOTE

OR ASSOCIATED KEYED NOTE FOR PURPOSE AND

REQUIREMENTS.

1. JUNCTION BOXES, DEVICES, BACKBOXES, ASSOCIATED CONDUIT, ETC., LOCATED ON

PRECAST CONCRETE WALLS SHALL BE SURFACE MOUNTED.

2. EACH PULL ROPE SHALL BE LABELED WITH A UNIQUE IDENTIFIER TAGGED ON EACH

END. THE USER END OF THE PULL ROPE SHALL ALSO INDICATE THE SOURCE

LOCATION.

3. DO NOT PENETRATE STRUCTURAL COLUMNS. AFIX DEVICES AND RACEWAY WITH

NON-PENETRATING BEAM C-CLAMPS, BRACKETS, CLIPS, AND UNISTRUT.

4. COORDINATE INTERCOMM DEVICE LOCATIONS SUCH THAT DEVICES ARE VISIBLE AND

NOT HIDDEN BEHIND DOORS.

5. ALL FURNITURE AND LANDSCAPE PLACEMENTS WILL NOT BLOCK CAMERA VIEWS.

J JUNCTION BOX, NEMA 1, 4"(W)x4"(L)x3"(D) NOMINAL. MOUNTED 48" AFG UON

JUNCTION BOX FOR BALANCED MAGNETIC SWITCH, 2" x 4" x 1-1/2", FLUSH MOUNTED ABOVE DOOR

FRAME. MAGNETIC SWITCH INSTALLATION BY OTHERS

JUNCTION BOX FOR MOTION DETECTOR, 2" x 4" x 1-1/2", FLUSH MOUNTED ON CEILING. MOTION

DETECTOR INSTALLATION BY OTHERS

DA SWITCH INSTALLATION BY OTHERS

FRONT ENTRY DOOR SWITCHDS

INTRUSION DETECTION SYSTEM PREMISE CONTROL UNIT. INSTALLATION BY OTHERS

BMS

PCU

MD

ISS-2 INTERCOM SUB STATION - DOOR STATION, SEE EY501/F5. PROVIDE DEDICATED CAT-5

CONNECTION FOR DEVICE. MOUNT AT 48" AFF.

CCTV NOTES:

1. CONDUIT, PULL ROPES, AND JUNCTION BOXES FOR POWER AND VIDEO FEED SHALL

BE PROVIDED FOR THE GFCI CCTV SYSTEM.

2. COORDINATE RACEWAY REQUIREMENTS AND CONFIGURATIONS WITH OWNER PRIOR

TO INSTALLATION.

3. PROVIDE NYLON PULL ROPE IN ALL EMPTY CONDUITS AND CCTV RACK IN ROOM 303.

4. ALL CONDUIT SHALL BE MINIMUM 1".

5. CCTV CABLES EN ROUTE TO A SIMILAR DESTINATION MAY SHARE CONDUIT. THE

MAXIMUM NUMBER OF CCTV CABLES PER CONDUIT SHALL BE AS FOLLOWS:

1" C: 3 CABLES

1 1/4" C: 5 CABLES

1 1/2" C: 8 CABLES

2" C: 14 CABLES

2 1/2" C: 22 CABLES

JUNCTION BOX FOR INTERIOR 360 DEGREE GFCI CCTV. MOUNTED 10'-0" AFF/AFG, UON.

CAMERA SCHEDULE

PVM GFCI CCTV PARENTAL VIEWING MONITOR (PVM). PROVIDE SINGLE GANG JUNCTION BOX

WITH REMOVABLE COVER.

PWS GFCI CCTV PVM WORKSTATION (PWS). PROVIDE SINGLE GANG JUNCTION BOX WITH

REMOVABLE COVER.

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EY001

SY

ST

EM

S

N O

TE

S

AN

D

S U

PP

LE

M

EN

TA

L

LE

G

EN

D

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

JJ

KITCHEN

DRY FOOD STORAGE

305A

LAUNDRY

MECHANICAL

CORRIDOR 01

PRESCHOOL/PRE-K/KINDERGARTEN

ACTIVITY ROOM

EXT. STORAGE

CENTRAL STORAGE

OUTREACH/TRANSITIONAL

CARE ACTIVITY ROOM

PRESCHOOL TOILET

101A

ELECTRICAL

OUTREACH STORAGE

012B

OUTREACH TOILET

012A

A

C-95

C-33

C-96 C-97

C-34 C-36

C-32

C-7

C-35

C-37

ISS-2

ISS-2 ISS-2

ISS-2

ISS-2

EY

EY

C-4

C-94

EXT. STORAGE

PRESCHOOL STORAGE

101B

PRESCHOOL STORAGE

102B

TOILET

C-28

C-98

A B C

D

E

A B E F

KEYPLAN

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EY101

SY

ST

EM

S

PL

AN

AR

EA

A

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

3/16" = 1'-0"A1 SYSTEMS PLAN - AREA A

0 2' 4' 8' 12'

M

A B C

D

E

A B E F

KEYPLAN

INFANT/PRE-TOD/TODDLER

ACTIVITY ROOM

ACTIVE PLAY ROOM 01

PRESCHOOL/PRE-K/KINDERGARTEN

ACTIVITY ROOM

STAFF LOUNGE

VESTIBULE

PUBLIC TOILET

003B

PUBLIC TOILET

003A

ASSISTANT DIRECTOR'S

OFFICE

004A

DIRECTOR'S OFFICE

004B

ADMIN STORAGE

005A

ISOLATION AREA

TOILET

005C

WAITING AREA

ISOLATION AREA

005B

OPEN OFFICE AREA

RECEPTION

TRAINING ROOM

CORRIDOR 01

JANITOR

STROLLER/CAR SEAT

AREA 02

ELECTRICAL

COMMUNICATIONS

CENTRAL STORAGE

INFANT/PRE-TOD/TODDLER

ACTIVITY ROOM

INFANT TOILET

201A

INFANT TOILET

212A

PRESCHOOL TOILET

102A

STROLLER/CAR SEAT

AREA 01

ACTIVE PLAY TOILET 01

008A

ACTIVE PLAY STORAGE

008B

TRAINING RM STORAGE

010A

CORRIDOR 02

B C D E

C-39 C-40

C-100

C-38

C-11

C-2

C-113

C-66

C-67

C-89

C-1

C-90

C-88

C-91 C-126C-93

C-12

IMS PV

M

CCTV

PARENTAL

VIEWING STATION

INTERCOM

MASTER

STATION

ISS-2 IS

S-

ISS-2 ISS-2

ISS-2ISS-2

IS

S-

ISS-2

ISS-2

ISS-2

CCTV MONITOR

EY104 EY104

EY

EY

EY

EY

C-6

C-92

C-5

C-3

PW

S

PVM

WORKSTATION

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EY102

SY

ST

EM

S

PL

AN

AR

EA

B

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

0 2' 4' 8' 12'3/16" = 1'-0"A1 SYSTEMS PLAN - AREA B

INFANT/PRE-TOD/TODDLER

ACTIVITY ROOM

INFANT/PRE-TOD/TODDLER

ACTIVITY ROOM

INFANT/PRE-TOD/TODDLER

ACTIVITY ROOM

EXT. STORAGE

INFANT STORAGE

204B

INFANT STORAGE

203B

NURSING MOTHERS

ROOM

INFANT/PRE-TOD/TODDLER

ACTIVITY ROOM

INFANT/PRE-TOD/TODDLER

ACTIVITY ROOM

EXT. STORAGE

INFANT STORAGE

206B

INFANT STORAGE

205B

TOILET

INFANT/PRE-TOD/TODDLER

ACTIVITY ROOM

INFANT STORAGE

208B

INFANT STORAGE

207B

EXT. STORAGE

INFANT STORAGE

210B

INFANT STORAGE

209B

EXT. STORAGE

BUGGY STORAGE

BUGGY STORAGE

INFANT TOILET

206A

INFANT/PRE-TOD/TODDLER

ACTIVITY ROOM

INFANT TOILET

205A

INFANT TOILET

204A

INFANT TOILET

207A

INFANT TOILET

209A

INFANT TOILET

208A

INFANT/PRE-TOD/TODDLER

ACTIVITY ROOM

F

CORRIDOR 01

INFANT/PRE-TOD/TODDLER

ACTIVITY ROOM

INFANT/PRE-TOD/TODDLER

ACTIVITY ROOM

C-114

C-69 C-70

C-68

C-17

C-71

C-116

C-73 C-74

C-72

C-83C-85

C-75

C-76

C-118

C-77

C-79

C-78

C-22

C-23C-24C-25C-26C-27

C-87

C-86 C-84 C-82 C-80

C-18

C-81

C-20

ISS-2

ISS-2 ISS-2

ISS-2ISS-2

ISS-2 ISS-2

ISS-2ISS-2

ISS-2

ISS-2

WP

EY

EY

2 ISS-2

WP

C-115 C-117

C-19

C-21

C-29 C-30

A B C

D

E

A B E F

KEYPLAN

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EY103

SY

ST

EM

S

PL

AN

AR

EA

C

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

3/16" = 1'-0"A1 SYSTEMS PLAN - AREA C

A B C

D

E

A B E F

KEYPLAN

PRESCHOOL/PRE-K/KINDERGARTEN

ACTIVITY ROOM

ACTIVE PLAY ROOM 02

PRESCHOOL/PRE-K/KINDERGARTEN

ACTIVITY ROOM

PRESCHOOL/PRE-K/KINDERGARTEN

ACTIVITY ROOM

PRESCHOOL STORAGE

109B

CENTRAL STORAGE

114PRESCHOOL STORAGE

103B

PRESCHOOL STORAGE

104B

EXT. STORAGE

PRESCHOOL TOILET

109APRESCHOOL TOILET

104A

PRESCHOOL TOILET

103A

ACTIVE PLAY STORAGE

009B

ACTIVE PLAY TOILET 02

009A

B C D E

C-45

C-102

C-44 C-46

C-60

C-111

C-59 C-61

C-112

C-64C-43C-42

C-41

C-63

C-10

C-62

C-101

ISS-2 ISS-2

ISS-2 ISS-2

ISS-2

ISS-2

WP

WP

EY105 EY105

C-9

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EY104

SY

ST

EM

S

PL

AN

AR

EA

D

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

0 2' 4' 8' 12'3/16" = 1'-0"A1 SYSTEMS PLAN - AREA D

EY102 EY102

PRESCHOOL/PRE-K/KINDERGARTEN

PRESCHOOL/PRE-K/KINDERGARTEN

ACTIVITY ROOM

CENTRAL STORAGE

PRESCHOOL STORAGE

105BPRESCHOOL STORAGE

106B

EXT. STORAGE

TOILET

118 PRESCHOOL STORAGE

108B

PRESCHOOL STORAGE

107B EXT. STORAGE

PRESCHOOL/PRE-K/KINDERGARTEN

ACTIVITY ROOM

PRESCHOOL TOILET

108A

PRESCHOOL TOILET

105A

PRESCHOOL TOILET

107A

PRESCHOOL TOILET

106A

PRESCHOOL/PRE-K/KINDERGARTEN

ACTIVITY ROOM

B C D E

ISS-2 ISS-2

ISS-2 ISS-2

ISS-2 ISS-2

WP

WP

C-106

C-105 C-51 C-52

C-15

C-53 C-54

C-107

C-108

C-55C-50

C-104

C-48 C-49

C-14

C-13

C-56 C-57

C-109

C-110

C-103

C-47 C-58

A B C

D

E

A B E F

KEYPLAN

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EY105

SY

ST

EM

S

PL

AN

AR

EA

E

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

3/16" = 1'-0"A1 SYSTEMS PLAN - AREA E

EY104 EY104

O O O

O O

MASTER STATION (1 EACH)

LOCATION: RECEPTION AREA ROOM 005

(SEE SHEET EY102)

(OPTIONAL) PC

DOOR SUB STATION (MULTIPLE)

(LOCATION: SEE SHEETS EY101 TO EY105)

POE (POWER OVER ETHERNET) SWITCH,

SEE GENERAL NOTE 2 AND 3

POE (POWER OVER ETHERNET) SWITCH,

SEE GENERAL NOTE 2 AND 3

LAN (LOCAL AREA NETWORK)

O O O

O O

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EY501

IN

TE

R C

O M

S

YS

TE

M

D

ET

AI

LS

S

YS

TE

M C

O N

FI

G

U R

AT

IO

N S

C H

ED

U

LE

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

NOT TO SCALEA1 TYPICAL IP SYSTEM CONFIGURATION

NOT TO SCALEF6 TYPE C - SUB STATION (IP)

NOT TO SCALEF1 TYPE A - MASTER STATION (IP)

NOTES:

1. WEATHERPROOF REQUIRED FOR EXTERIOR INSTALLATIONS.

GENERAL NOTES:

1. ALL MASTER STATION ADN SUBSTATIONS SHALL BE IP BASED AND POWERED

OVER ETHERNET (POE).

2. FOLLOW MANUFACTURER'S REMCOMMENDATIONS REGARDING IP SYSTEM

CONFIGURATION AND DEVICE SETUP.

3. POE (POWER OVER ETHERNET) SWITCH SHALL BE LOCATED IN ROOM 303 UNLESS

ANOTHER LOCATION IS RECOMMENDED BY THE MANUFACTURER/VENDOR.

SPACE ABOVE CEILING

3/4" EMT CONDUIT, GF/GI

CEILING

GF/GI CCTV CAMERA DEVICES

AND EQUIPMENT TO BE

PROVIDED BY OTHERS

SPACE ABOVE CEILING

3/4" EMT CONDUIT, GF/GI

CEILING

GF/GI CCTV CAMERA DEVICES

AND EQUIPMENT TO BE

PROVIDED BY OTHERS

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EY502

C

LO

SE

D

C

IR

C U

IT

T

EL

EV

IS

IO

N (C

C

TV

IN

FR

AS

TR

U

C

TU

R E

D

ET

AI

LS

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

K.

C

H O

Y

M

AY

DESIGN COMPLETE

SHEET NOTES:

1. UNLESS NOTED OTHERWISE, THE MILCON MUST PROVIDE ALL ITEMS SHOWN.

2. THERE MUST NOT BE MORE THAN THE EQUIVALENT OF THE TWO QUARTER BENDS (180° TOTAL) BETWEEN

PULL POINTS (CONDUIT BODIES AND BOXES) PER TM-569.

3. ALL SURFACE MOUNTED BOXES MUST NOT HAVE KNOCKOUTS.

4. CAT-6 CABLE TERMINATED TO SURFACE MOUNT RJ45 JACK.

SHEET KEYNOTES:

1 NEMA 1 ENCLOSURE 8"x8"x4" WITH CONTINUOUS HINGE, LOCKING CLAMP COVER AND ALUMINUM BACKPLATE

2 SURFACE MOUNT RJ45 JACK

3 1 1/2" EMT CONDUIT WITH PULL STRING

4 CAT-6 CABLE

5 GROUNDING TERMINATION

NOT TO SCALEB1 CCTV DETAIL - WALL MOUNTED

NOT TO SCALEB5 CCTV DETAIL - CEILING MOUNTED

HORIZONTAL

DISTRIBUTION

FIRST FLOOR

CCTV ROOM 303

SEE EQUIPMENT

RACK

ELEVATION ON

SHEET D6/T-504

SURVEILLANCE

EQUIPMENT

RACK (SER)

FIRST FLOOR

RECEPTION 005

SHEET NOTES:

1. PROVIDE CCTV INFRASTRUCTURE AND DEVICES INCLUDING, BUT NOT LIMITED TO

JUNCTION BOXES, PULL BOXES, CONDUIT WITH PULL WIRE, AND SUPPORTS, ETC.

AS INDICATED.

2. SEE SHEETS EY101 THROUGH EY105 FOR PROPOSED CCTV CAMERA, DEVICE, AND

EQUIPMENT LOCATIONS.

3. SEE SHEET EY502 FOR CCTV INFRASTRUCTURE DETAILS.

4. CAMERA SCHEDULE LOCATED ON SHEET EY001.

SHEET KEYNOTES:

1-1/2" CONDUIT, ROUTE FROM DEVICE TO SER RACK.1

INTERCOM

SUB

STATION

(GFCI)

INTERCOM

MASTER

STATION

(GFCI)

PVM

WORK-

STATION

(GFCI)

PARENTAL

VIEWING

MONITOR

(GFCI)

CCTV

CAMERA

360 DEGREE

(GFCI)

CCTV

CAMERA

(GFCI)

ISS-2 IMS PWS PVM

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EY601

C

LO

SE

D

-C

IR

C U

IT

T

EL

EV

IS

IO

N (C

C

TV

) A N

D

IN

TE

R

C O

M

IN

FR

AS

TR

U

C

TU

R E

R

IS

ER

D

IA

G

R

AM

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

K.

C

H O

Y

M

AY

DESIGN COMPLETE

NOT TO SCALEA1

CLOSED-CIRCUIT TELEVISION (CCTV) AND INTERCOM

INFRASTRUCTURE RISER DIAGRAM

TELECOMMUNICATIONS OUTLET, ONE VOICE & ONE DATA LINE,

+18" AFF UON.

SINGLE DATA OUTLET, +18" AFF UON.

SYMBOLS:

SINGLE VOICE OUTLET, +18" AFF UON.

CATV OUTLET, TYPE "F" CONNECTOR, +18" AFF

UON.TV

TELECOMMUNICATIONS EQUIPMENT RACK

PRIMARY BONDING GROUND BUS BAR (PBB)

C111.01

PBB

SBB SECONDARY BONDING BUS BAR (SBB)

LARGE PULL BOX, SIZE AS INDICATED.

NEMA 4X, CEILING MOUNTED UON.P

PET PROTECTIVE ENTRANCE TERMINAL

110 110 BLOCKS

1" TELECOM CONDUIT WITH CAT-6 CABLES. STUB CONDUIT

TO CABLE TRAY WITH CONDUIT CLAMP. HOMERUN CABLE

TO TELECOM ROOM. ENSURE TELECOM CONDUITS

CONCEALED WHERE POSSIBLE.

SMALL JUNCTION (OUTLET BOX), NEMA 1 WALL

MOUNTED +18" AFF UON. J

T2 TELECOM CONDUIT WITH CAT-6 CABLES. STUB CONDUIT TO CABLE TRAY

UON. HOMERUN CABLE TO TELECOM ROOM. CONDUITS EXPOSED. PROVIDE

EMT CONDUIT INDOORS.

CONDUIT (HORIZONTAL)

CONDUIT (VERTICAL)

TELECOM CONDUIT, STUB TO CABLE TRAY PROVIDE PULLWIRE IN

SPARE CONDUITS.

CABLE TRAY, LADDER TYPE, 18"(W) x 1.5"(H), MTD. 8" A.F.F. NOM.

LEGEND:

CABLE TRAY, WIRE BASKET TYPE. 12"(W) x 4"(H) BASKET TYPE

MOUNTED ABOVE CEILING.

PLYWOOD BACKBOARD

CABLE LADDER, 24"(W) x 1.5" (D), WALL MTD.

TELECOM CONDUIT WITH CAT-6 CABLES. STUB CONDUIT TO

CABLE TRAY UON. HOMERUN CABLE TO TELECOM ROOM.

ENSURE TELECOM CONDUITS CONCEALED WHERE

POSSIBLE. PROVIDE EMT CONDUIT UON.

T2

1" CATV CONDUIT WITH RG-6 CABLES, HOMERUN CABLES TO

TELECOM ROOM. ENSURE CATV CONDUITS CONCEALED

WHERE POSSIBLE. PROVIDE EMT CONDUIT UON.

ABBREVIATIONS:

A AMPERE

AC ALTERNATING CURRENT

ACS ACCESS CONTROL SYSTEM

AF AMPERE FRAME

AFF ABOVE FIXED FLOOR

AGL ABOVE GROUND LEVEL

AHU AIR HANDLING UNIT

AIC AMPERE INTERRUPTING CAPACITY

ANT ANTENNA

AP AIMING POINT

AT AMPERE TRIP

AUTO AUTOMATIC

AWG AMERICAN WIRE GAUGE

BATT BATTERY

BC BARE COPPER

BLDG BUILDING

BRKR BREAKER

BTU BRITISH THERMAL UNIT

C CONDUIT

CAT CATALOG

CATV COMMUNITY ANTENNA TELEVISION

CB CIRCUIT BREAKER

CKT CIRCUIT

CLG CEILING

CONC CONCRETE

COND CONDUCTOR

CONN CONNECTION

CONT CONTROL

CORR CORRIDOR

CP CATHODIC PROTECTION

CT CURRENT TRANSFORMER

CU CONTROL UNIT

DB DIRECT BURIAL

dB DECIBEL

DC DIRECT CURRENT

DEG DEGREE

DET(S) DETAIL(S)

DF DEMAND FACTOR

DIA DIAMETER

DIAG DIAGRAM

DISC DISCONNECT

DOIM DIRECTORATE OF INFORMATION

MANAGEMENT

DPW DIRECTORATE OF PUBLIC WORKS

DWG(S) DRAWING(S)

EA EACH

ELEC ELECTRICAL

EMER EMERGENCY

ENCL ENCLOSURE

EP EXPLOSION PROOF

EQL EQUAL

EQUIP EQUIP

EXH EXHAUST

EXST EXISTING

EXT EXTERIOR

FA FIRE ALARM

FCP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FG FINISH GRADE

FL FLOOR

FM FLOOR MOUNT

FLUOR FLUORESCENT

FT FOOT (FEET)

FU FUSE

FXTR FIXTURE

G GROUNDING CONDUCTOR

GALV GALVANIZE

GEN GENERATOR

GFCI GROUND FAULT CIRCUIT INTERRUPT

GF/CI GOVERNMENT FURNISHED/ CONTRACTOR

INSTALLED

GF/GI GOVERNMENT FURNISHED/ GOVERNMENT

INSTALLED

GL GROUND LEVEL

GND GROUND OR GROUNDING

HDBC HARD DRAWN BARE COPPER

HH HANDHOLE

HP HORSEPOWER

HPS HIGH PRESSURE SODIUM

HR HOUR

HV HIGH VOLTAGE

HZ HERTZ

IDS INTRUSION DETECTION SYSTEM

IN INCH

INCAND INCANDESCENT

INCL INCLUDE

INSTL INSTALLATION

INTERCOM INTERCOMMUNICATIONS

INTR INTERIOR

JB JUNCTION BOX

JC JANITOR CLOSET

J-SIIDS JOINT-SERVICE INTERIOR INTRUSION

DETECTION SYSTEM

K KILO

KV KILOVOLT

KCMIL THOUSAND CIRCULAR MILS

KVA KILOVOLT-AMPERE

KW KILOWATT

L LONG

LA LIGHTNING ARRESTER

LAN LOCAL AREA NETWORK

LG LENGTH

LPS LOW PRESSURE SODIUM

LTG LIGHTING

LV LOW VOLTAGE

MAG MAGNETIC

MAN MANUAL

MAX MAXIMUM

MECH MECHANICAL

MED MEDIUM

MH MOUNTING HEIGHTS

MIN MINIMUM

MS MOTOR STARTER

MTD MOUNTED

MTG MOUNTING

MTR METER

MWR OFFICE OF MORALE, WELFARE, AND

RECREATION

NIC NOT IN CONTRACT

NIPR NONSECURED INTERNET PROTOCOL

ROUTER NETWORK

NO NUMBER

NEMA NATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATION

OC OVERCURRENT

O/H OVERHEAD

OL OVERLOAD

ONU OPTICAL NODE UNIT

P POLE

PA PUBLIC ADDRESS

PAR PARALLEL

PF POWER FACTOR

PH PHASE

PNLBD PANELBOARD

PRI PRIMARY

PROT PROTECTION

PVC POLYVINYL CHLORIDE CONDUIT

PWR POWER

QTY QUANTITY

RCPT RECEPTACLE

REPL REPLACE

REQ'D REQUIRED

RGS RIGID ZINC-COATED STEEL CONDUIT

RM ROOM

RPM REVOLUTIONS PER MINUTE

RR REMOVE & REINSTALL

RTU REMOTE TERMINAL UNIT

SAF SAFETY

SCHED SCHEDULE

SEC SECONDARY

SECT SECTION

SEL SELECTOR

SERV SERVICE

SH SHEET

SIG SIGNAL

SM SURFACE MOUNT

SN SOLID NEUTRAL

SPEC SPECIFICATION

SQ SQUARE

SS STAINLESS STEEL

STA STATION

STD STANDARD

STL STEEL

STOR STORAGE

SURF SURFACE

SW SWITCH

SYS SYSTEM

TEL TELEPHONE

TEMP TEMPERATURE

TERM TERMINAL

TGB TELECOMMUNICATIONS GROUND BUS BAR

THK THICK

TMGB TELECOMMUNICATIONS MAIN GROUND BUS BAR

TMH TELECOMMUNICATIONS MAINTENANCE HOLE

TMR TIMER

TR TELECOMMUNICATIONS ROOM

TTC TELEPHONE TERMINAL CABINET

TYP TYPICAL

TV TELEVISION

U/G UNDERGROUND

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTED POWER SUPPLY

V VOLT

VA VOLT-AMPERE

W WATT

W/ WITH

W/O WITHOUT

WHM KILOWATT-HOUR METER

WP WEATHERPROOF

XFR TRANSFER

XFMR TRANSFORMER

& AND

# NUMBER

ɸ PHASE

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

T-001

TE

LE

C O

M M

U N

IC

AT

IO

N

S

SY

M

BO

LS

, L

EG

EN

D , A

N D

AB

BR

EV

IA

TI

O

N S

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

TELECOMMUNICATIONS GENERAL NOTES:

1. THE CONTRACTOR SHALL COMPLY WITH THE LATEST VERSION OF ALL APPLICABLE CRITERIA

INCLUDING, BUT NOT LIMITED TO NFPA 70 AND UFC.

2. ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED OR APPROVED AS INDICATED.

3. SHOP DRAWINGS OR ANY WORK FOR TELECOMMUNICATIONS SYSTEMS SHALL BE PROVIDED TO

THE CONTRACTING OFFICER AND BE APPROVED PRIOR TO ANY WORK TAKING PLACE.

4. THE CONTRACTOR SHALL COORDINATE WITH THE 30TH SIGNAL BATTALION NEC FOR REMOVAL OF TELECOMMUNICATIONS EQUIPMENT FOR DEMOLITION, INCLUDING BUT NOT LIMITED TO NETWORK

SWITCHES AND SIPRNET SAFE.

5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED AREA INCLUDING

SODDING, UTILITIES, STRUCTURES, ETC TO THEIR ORIGINAL CONDITION AND OPERATION DURING AND AFTER INSTALLATION OF ELECTRICAL SYSTEM. THE GRADING LINE OF NEW DUCTS WILL BE

LIMITED TO THE WIDTH OF DUCT EXCAVATION.

6. WHEN UNKNOWN EXISTING UNDERGROUND TELECOMMUNICATIONS CABLES ARE FOUND IN THE

PROJECT SITE DURING CONSTRUCTION BY THE CONTRACTOR, ANY REMOVAL OR RELOCATION

WORK SHALL BE COORDINATED WITH THE CONTRACTING OFFICE AND THE 30TH SIGNAL

BATTALION NEC.

7. FOR ANY REMOVAL WORK THAT WILL REQUIRE DIGGING, THE CONTRACTOR MUST HAVE DIGGING PERMITS SUBMITTED TO THE 30TH SIGNAL BATTALION NEC TO IDENTIFY ANY COMMUNICATIONS

CABLES THAT MAY BE AFFECTED BY THIS PROJECT. CONTRACTOR TO COORDINATE WITH DPW

AND FIELD OFFICE TO DETERMINE IF THERE ARE ANY OTHER UTILITIES WITHIN THE PROJECT SITE.

8. LABELING / IDENTIFICATION NUMBER OF EACH COMMUNICATIONS DROPS AND CABINET RACKS

SHALL BE PERFORMED BY THE CONTRACTOR IN ACCORDANCE WITH 30TH SIGNAL BN LABELING

STANDARD, DATED JAN 2011.

9. THE CONTRACTOR SHALL TERMINATE ALL TELECOMMUNICATIONS CABLE BETWEEN THE

COMMUNICATIONS ROOM AND EVERY JACK. CABLES IN TRAY SHALL BE BUNDLED BY SYSTEM /

TYPE (VOICE, DATA, SIPRNET, ETC). CONTRACTOR SHALL NOTIFY THE GOVERNMENT PRIOR TO

COMPLETION OF FINAL CABLE TERMINATIONS.

10. ALL ELECTRICAL JUNCTION BOXES, PULL BOXES, WIRING TRAYS, ETC SHALL BE ACCESSIBLE TO AUTHORIZED PERSONNEL DURING FINAL INSPECTION IN FINISHED STATE PER NEC 300.23 AND 314.29.

11. PROVIDE GROUNDING IN ACCORDANCE WITH ANSI/TIA-607-C (2015) AND MIL-STD-188-124B. DO NOT

BOND TMGB/TGB TO FAULT PROTECTION GROUND SYSTEM. PROVIDE GROUNDING ELECTRODE

CONDUCTOR, MINIMUM #1/0 AWG IN SIZE ANDTERMINATE AT THE FACILITY EARTH ELECTRODE

SYSTEM. BOND THE SIGNAL GROUND BAR TO THE GROUND CABLE, WITH BONDING CONDUCTOR,

MINIMUM #1/0 AWG.

12. TELECOMMUNICATIONS, CIRCUITS SHALL NOT PENETRATE ANY STAIR OR EXIT PASSAGEWAY UNLESS THIS CIRCUIT SERVICES AN APPLIANCE REQUIRED FOR AND INSTALLED WITHIN THE STAIR

OR EXIT PASSAGEWAY.

13. ALL UNDERGROUND CONDUITS SHALL BE CONCRETE ENCASED SCHEDULE 40 PVC CONDUITS

EXCEPT ANY CONDUIT PENETRATING AND PASSING THROUGH BLDG CONCRETE SLAB SHALL BE

RIGID STEEL CONDUIT. USE OF RIGID STEEL CONDUIT SHALL BE ALSO USED WITHIN 6" PRIOR TO

PENETRATING CONCRETE SLAB.

14. CONDUITS SHALL EXTEND BETWEEN 4" TO 6" AFF TO AID IN PULLING CABLES AND SHALL BE PLACED WITHIN 3" OF THE WALL. IN ADDITION, WHERE CONDUITS ENTERS A BUILDING AND SWEEPS

UP THROUGH A FLOOR SLAB, GALVANIZED RSC SHALL BE USED.

15. TELECOMMUNICATIONS CONDUIT SHALL BE ELECTRICAL METALLIC TUBING (EMT). CONDUITS SIZES 1" DIAMETER OR SMALLER ARE ALLOWED TO BE EMBEDDED IN CONCRETE FLOOR SLAB. CONDUITS LARGER THAN 1" DIAMETER SHALL NOT BE INSTALLED IN CONCRETE FLOOR OR WALL. CONDUITS IN

CONCRETE SLABS SHALL NOT OVERLAP. THE CONTRACTOR SHALL FOLLOW ACI 318-83 CHAPTER

6.3 FOR MINIMUM SLAB THICKNESS AND MAXIMUM CONDUIT SIZE. WHERE CONDUIT IS EMBEDDED

IN SLAB OUTDOOR RATED CAT-6 CABLE SHALL BE PROVIDED.

16. 12" CLEARANCE SHALL BE PROVIDED ABOVE TELECOMMUNICATIONS CABLE RAY. IF ANY

TELECOMMUNICATIONS CABLE TRAY INSTALLED ABOVE THE CORRIDOR CEILING CONFLICTS WITH MECHANICAL DUCTS OR ANY PIPINGS, THE CONTRACTOR SHALL COORDINATE AT THE FIELD WITH

SHOP DRAWINGS.

17. ANY CIRCUIT OF VOICE/DATA SYSTEM SHALL BE 4 PAIR, UNSHIELDED TWISTED PAIR (UTP), CATEGORY 6 CABLE.

18. ANY OUTLET BOXES FOR RECEPTACLES, TELECOMMUNICATIONS, CATV, ETC SHALL NOT BE

INSTALLED BACK TO BACK ON A COMMON WALL.

19. MOUNTING HEIGHTS ABOVE FINISHED FLOOR SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED.

TELECOMMUNICATIONS OUTLET____18" TO CENTER OF OUTLET

VOICE OUTLET____________________18" TO CENTER OF OUTLET

20. PER I3A, PROVIDE 3 INCH BY 3 CELL FABRIC CELL INTERDUCT FOR UNDERGROUND

TELECOMMUNICATION PATHWAYS, MINIMUM ONE PER RUN (EG. PROVIDE FOR ONE DUCT OF THE 4-

WAY).

21. TELECOM PULL BOXES SHALL BE PLACED ON STRAIGHT SECTIONS OF CONDUIT AND NOT USED IN

LIEU OF A BEND.

22. TELECOM PULLBOXES SHALL BE PLACED IN CONDUIT RUNS WHERE A CONTINUOUS CONDUIT

EXTENDS OVER 100' OR WHERE THERE ARE MORE THAN TWO 90 DEGREE BENDS.

23. TELECOM OUTLETS SHALL BE LOCATED WITHIN 6 INCHES OF A POWER RECEPTACLE.

24. CONTRACTOR SHALL SUBMIT AN AT&T CONDUIT OCCUPANCY REQUEST FORM FOR THE NEW

CONDUIT INFRASTRUCTURE AND MUST BE APPROVED BEFORE INSTALLATION STARTS. THE

CONTRACTOR IS RESPONSIBLE FOR COSTS ASSOCIATED WITH AT&T/PES-HI SERVICES PROVIDED.

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

T-002

TE

LE

C O

M M

U N

IC

AT

IO

N

S G

EN

ER

AL

N

O

TE

S

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

SASSAFRAS DRIVE

MOANALUA FREEWAY

GENERAL NOTES:

1. REMOVE (12) EXISTING UTILITY POLES FROM THE PROJECT SITE.

REMOVE EXST UTIL POLE

AND ANY ATTACHED GUY

WIRE, TYP - (12) TOTAL

REMOVE OVERHEAD (OH) TELECOM LINES, TYP

HALAIW

A VALLEY LOOP

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

TD101

D

EM

O

LI

TI

O

N T

EL

EC

O M

S

IT

E

PL

AN

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

KCK.

C

H O

Y

M

AY

DESIGN COMPLETE

1" = 50'-0"A1 DEMOLITION TELECOMMUNICATIONS SITE PLAN

0 50'25' 100'

TR

EE

D= 4'

H

FEA DCB

IN FANT / PR E- TOD /T OD D LER AC T IV IT Y

R OOM

20 8

IN FANT / PR E- TOD /T OD D LER AC T IV IT Y

R OOM

20 9

IN FANT / PR E- TOD /T OD D LER AC T IV IT Y

R OOM

21 0

IN FANT / PR E- TOD /T OD D LER AC T IV IT Y

R OOM

21 1

IN FANT / PR E- TOD /T OD D LER AC T IV IT Y

R OOM

21 2

DR Y F OOD ST OR AGE

30 5 A

MEC H ANI C AL

30 2

AC T IVE PL AY R OOM 0 1

00 8

PR ESCH OOL /PR E-K/ K I ND ER GAR T EN

AC T IV I TY ROOM

10 2

ST AFF L OU N GE

01 1

IN FANT / PR E- TOD /T OD D LER AC T IV IT Y

R OOM

20 2

EXT . ST OR AGE

21 6

IN F AN T ST ORAGE

20 4 B

IN F AN T ST ORAGE

20 3 B

NU R SI N G MOT H ERS R OOM

21 5

IN FANT / PR E- TOD /T OD D LER AC T IV IT Y

R OOM

20 4

IN FANT / PR E- TOD /T OD D LER AC T IV IT Y

R OOM

20 5

EXT . ST OR AGE

21 8

IN F AN T ST ORAGE

20 6 B

IN F AN T ST ORAGE

20 5 B

TOI LET

21 7

IN FANT / PR E- TOD /T OD D LER AC T IV IT Y

R OOM

20 6

IN F AN T ST ORAGE

20 8 B

IN F AN T ST ORAGE

20 7 B

EXT . ST OR AGE

22 0

IN F AN T ST ORAGE

21 0 B

IN F AN T ST ORAGE

20 9 B

EXT . ST OR AGE

22 2

IN F AN T ST ORAGE

21 2 B

IN F AN T ST ORAGE

21 1 B

EXT . ST OR AGE

22 4

VEST I BU L E

00 1

PU BL IC T OI LET

00 3 B

PU BL IC T OI LET

00 3 A

ASSI ST ANT D I RECT OR' S OFF IC E

00 4 A

DI RECT OR' S OFF IC E

00 4 B

AD MI N ST OR AGE

00 5 A

ISOL ATI ON AREA T OIL ET

005 C

TOI LET

21 3

IN F AN T ST ORAGE

20 1 B

IN F AN T ST ORAGE

20 2 B

EXT . ST OR AGE

21 4

BU GGY ST OR AGE

21 9

BU GGY ST OR AGE

22 1

BU GGY ST OR AGE

22 3

WAI TI N G AR EA

00 2

ISOLAT ION AR EA

00 5 B

OPEN OF FI C E AR EA

00 4

REC EPT I ON

00 5

TR AI NI N G R OOM

01 0

JAN IT OR

30 9

PR ESCH OOL /PR E-K/ K I ND ER GAR T EN

AC T IV I TY ROOM

10 3

PR ESCH OOL /PR E-K/ K I ND ER GAR T EN

AC T IV I TY ROOM

10 4

PR ESCH OOL /PR E-K/ K I ND ER GAR T EN

AC T IV I TY ROOM

10 5

PR ESCH OOL /PR E-K/ K I ND ER GAR T EN

AC T IV I TY ROOM

10 6

CEN T R AL ST OR AGE

11 6

PR ESC H OOL ST OR AGE

10 5 B

PR ESC H OOL ST OR AGE

10 6 B

EXT . ST OR AGE

11 7

TOI LET

11 8

PR ESC H OOL ST OR AGE

10 8 B

PR ESC H OOL ST OR AGE

10 7 B

EXT . ST OR AGE

11 9

PR ESCH OOL /PR E-K/ K I ND ER GAR T EN

AC T IV I TY ROOM

10 8

PR ESCH OOL /PR E-K/ K I ND ER GAR T EN

AC T IV I TY ROOM

10 9

PR ESC H OOL ST OR AGE

10 9 B

CEN T R AL ST OR AGE

11 4

PR ESC H OOL ST OR AGE

10 3 B

PR ESC H OOL ST OR AGE

10 4 B

EXT . ST OR AGE

11 5

ST R OL L ER / CAR SEAT AR EA 0 2

00 7

EL ECT R IC AL

30 8

AC T IVE PL AY R OOM 0 2

00 9

COMMU N IC AT I ON S

30 6

CEN T R AL ST OR AGE

30 7 IN FANT / PR E- TOD /T OD D LER AC T IV IT Y

R OOM

20 3

IN FANT / PR E- TOD /T OD D LER AC T IV IT Y

R OOM

20 1

OU T REACH / TR ANSI T ION AL CAR E

AC T IV I TY ROOM

01 2

PR ESCH OOL /PR E-K/ K I ND ER GAR T EN

AC T IV I TY ROOM

10 1

EXT . ST OR AGE

11 1

CEN T R AL ST OR AGE

11 0

INF AN T TOIL ET

20 6 A

INF AN T TOIL ET

20 5 A

INF AN T TOIL ET

20 4 A

INF AN T TOIL ET

20 3 A

INF AN T TOIL ET

20 2 A

INF AN T TOIL ET

20 1 A

INF AN T TOIL ET

20 7 A

INF AN T TOIL ET

20 9 A

INF AN T TOIL ET

20 8 A

INF AN T TOIL ET

21 1 A

INF AN T TOIL ET

21 0 A

INF AN T TOIL ET

21 2 A

PR ESC HOOL TOI L ET

10 1 A

PR ESC HOOL TOI L ET

10 2 A

PR ESC HOOL TOI L ET

10 8 A

PR ESC HOOL TOI L ET

10 9 A

PR ESC HOOL TOI L ET

10 5 A

PR ESC HOOL TOI L ET

10 4 A

PR ESC HOOL TOI L ET

10 7 A

PR ESC HOOL TOI L ET

10 6 A

PR ESC HOOL TOI L ET

10 3 A

EL ECT R IC AL

30 1

COR RI D OR 0 1

01 4

ST R OL L ER / CAR SEAT AR EA 0 1

00 6

OU T R EAC H ST OR AGE

01 2 B

IN FANT / PR E- TOD /T OD D LER AC T IV IT Y

R OOM

20 7

AC T IVE PL AY ST OR AGE 0 2

00 9 B

TR AIN I N G R M ST ORAGE

01 0 A

AC T IVE PL AY ST OR AGE 0 1

00 8 B

AC TI VE PL AY T OI L ET 0 1

00 8 A

OU TR EAC H T OIL ET

01 2 A

PR ESCH OOL /PR E-K/ K I ND ER GAR T EN

AC T IV I TY ROOM

10 7

LAU N D R Y

30 4

CC T V EQU I PMEN T

30 3

COR RI D OR 0 1

01 4

COR RI D OR 0 1

01 4

COR RI D OR 0 2

01 5

COR RI D OR 0 1

01 4

COR RI D OR 0 2

01 5

COR RI D OR 0 2

01 5

COR RI D OR 0 2

01 5

COR RI D OR 0 2

01 5

COR RI D OR 0 1

01 4

AC TI VE PL AY T OI L ET 0 2

00 9 A

EXT . ST OR AGE

11 3

PR ESC H OOL ST OR AGE

10 1 B

PR ESC H OOL ST OR AGE

10 2 B

TOI LET

11 2

KI TC HEN

30 5

SASSAFRAS DRIVE

CCTV ROOM 303

NEW 1-WAY UG, CONCRETE ENCASED

CATV DUCT LINE, SEE SHEET T-505/A1

NEW CATV HANDHOLE,

SEE SHEET T-509

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

TS101

TE

LE

C O

M M

U N

IC

AT

IO

N

S

IT

E

PL

AN

FY

P N

C

H

IL

D D

EV

EL

O

PM

EN

T

C

EN

TE

R

AL

IA

M

AN

U M

IL

IT

AR

Y

R

ES

ER

VA

TI

O

N , O

AH

U

, H

AW

AI

I

H O

N O

LU

LU

D

IS

TR

IC

T, B

U

IL

D

IN

G

FO

R T

SH

AF

TE

R

, O

AH

U , H

I 9

-5

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

E

N G

IN

EE

R

IN

G D

IS

TR

IC

T

H O

N O

LU

LU

, H

AW

AI

I

M . L

AM

M . S

TA

N

SB

U

R Y

K.

C

H O

Y

M

AY

DESIGN COMPLETE

1" = 40'-0"A1 TELECOMMUNICATION SITE PLAN - 1

KEY NOTES:

1 TRANSITION PVC CONDUIT TO GRS; SEE A1/T-401 FOR LOCATION OF UG

STUBUPS.

EXST TMH 12

EXST TMH-12A, SEE

SHEET T-506/A1

H

AL

AW

A

VI

EW

L O

O

PNEW CHILD

DEVELOPMENT

CENTER BLDG

PRE-KINDERGARTEN

PLAYGROUND

TELECOM

RM 306

TODDLER/PRESCHOOL

PLAYGROUND

ALI…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .