PN96540_DESIGN COMPLETE_DWG_Part1.pdf

PDF 17 MB Posted

Attached to
FY22 Military Construction Army (MCA) 096540 Child Development Center, Aliamanu Military Reservation, Oahu, Hawaii
Solicitation number
W9128A22R0019
Issued by

About this file

This solicitation announcement is for a construction project to build a Child Development Center at Aliamanu Military Reservation in Oahu, Hawaii. The project scope includes the development center building with learning and activity areas, administrative spaces, kitchen, laundry, storage, and outdoor play areas. Supporting facilities such as site work, utilities, parking, lighting, drainage, and landscaping are also required. Work will be performed over 1,048 calendar days with a project budget between $50-100 million. The solicitation is being issued via a Lowest Price Technically Acceptable request for proposal. Proposals will be evaluated on experience, past performance, technical approach, and price, with award going to the best valued offer. The Department of the Army Corps of Engineers Engineering District Honolulu is the issuing agency. An organized site visit will be held on July 6, 2022.

View the file

Other files

Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT

LOCATION

LOCATION MAP

VICINITY MAP

This project was designed by the Honolulu District of the U.S. Army Corps of Engineers. The initials or signatures and registration designations of individuals appear on these project documents within the scope of their employment as required by ER 111-1-8152.

Approved by: ___________________________________________ Chief, Regional Engineering Center

Approved by: ____________________________________________ Chief, Engineering and Construction Division

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

US Army Corps of Engineers ®

ISSUE DATE.:

M A

R K

D E

S C

R

IP

T

IO

N

G-001

C O

V E

R S

H E

E T

A L

IA

M A

N U

M

IL

IT

A

R Y

R E

S E

R V

A T

IO

N

O

A H

U H

A W

A

II

H O

N O

L U

L U

D

IS

T R

IC

T

B

U

IL

D

IN

G

F O

R T

S H

A F

T E

R O

A H

U H

A W

A

II

-5

R E

G

IO

N A

L E

N G

IN

E

E R

IN

G

C E

N T

E R

H O

N O

L U

L U

E N

G

IN

E E

R

IN

G D

IS

T

R

IC

T H

O N

O L U

L U

H

A W

A

II

J L

R S

E J

T O

M

A Y

N /A

N /A

DESIGN COMPLETE

F Y

P

N C

H

IL

D D

E V

E L O

P M

E N

T C

E N

T E

R

HONOLULU DISTRICT, BUILDING 230

FY21 PN96540 CHILD DEVELOPMENT CENTER

06 MAY 2022

ALIAMANU MILITARY RESERVATION, OAHU, HAWAII

NORTH

NORTH

OPTION DESCRIPTIONS

PROJECT INCLUDES FOLLOWING OPTION ITEMS

OPTION 1. REMOVE EXISTING BANYAN TREE AND REVISE PARKING LOT LAYOUT. OPTION 1 DRAWINGS HAVE 'A' IN DRAWING NAMES. SEE CIVIL, LANDSCAPING, STRUCTURAL, ARCHITECTURAL, ELECTRICAL AND TELECOMMUNICATION DRAWINGS.

OPTION 2. ADD ROOF DORMERS. SEE STRUCTURAL AND ARCHITECTURAL DRAWINGS.

OPTION 3. ADD RETAINING WALL PATTERNS. SEE ARCHITECTURAL DRAWINGS. USE THE FOLLOWING SUB OPTIONS.

OPTIONS 3a. RETAINING WALL PATTERN FOR BASE SITE PLAN OPTIONS 3b. RETAINING WALL PATTERN FOR OPTION 1 SITE PLAN

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F Y

P

N C

H

IL

D D

E V

E L O

P M

E N

T C

E N

T E

R A

L

IA

M A

N U

M

IL

IT

A

R Y

R E

S E

R V

A T

IO

N

O

A H

U H

A W

A

II

H O

N O

L U

L U

D

IS

T R

IC

T

B

U

IL

D

IN

G

F O

R T

S H

A F

T E

R O

A H

U H

A W

A

II

-5

R E

G

IO

N A

L E

N G

IN

E

E R

IN

G

C E

N T

E R

H O

N O

L U

L U

E N

G

IN

E E

R

IN

G D

IS

T

R

IC

T H

O N

O L U

L U

H

A W

A

II

G-002

S H

E E

T I

N D

E X

J L

R S

E J

T O

M

A Y

N /A

N /A

DESIGN COMPLETE

SHEET I.D. SHEET TITLE REVISION

GENERAL

G-001 COVER SHEET

G-002 SHEET INDEX

SHEET COUNT: 2

CIVIL

V-001 EXISTING CONDITIONS

BJ001 BORING LOCATION PLAN

BJ002 BORING LOGS - 1

BJ003 BORING LOGS - 2

BJ004 BORING LOGS - 3

BJ005 BORING LOGS - 4

BJ006 BORING LOGS - 5

C-001 NOTES

C-002 NOTES, LEGEND AND ABBREVIATIONS

C-003 EROSION CONTROL PLAN

C-004 EROSION CONTROL DETAILS

C-005 EROSION CONTROL NOTES

C-006 HAUL ROUTE AND COSA

CD101 DEMOLITION PLAN

CS101 OVERALL SITE PLAN

CS102 SITE PLAN - 1

CS102A SITE PLAN - 1, BID OPTION

CS103 SITE PLAN - 2

CS501 SITE DETAILS - 1

CS502 SITE DETAILS - 2

CS503 SITE DETAILS - 3

CP101 SIGNING AND STRIPING PLAN

CP101A SIGNING AND STRIPING PLAN, OPTION

CP501 SIGNING AND STRIPING DETAILS - 1

CP502 SIGNING AND STRIPING DETAILS - 2

CG101 OVERALL GRADING PLAN

CG102 GRADING PLAN - 1

CG102A GRADING PLAN - 1, OPTION

CG103 GRADING PLAN - 2

CG104 GRADING DETAILS - 1

CG105 GRADING DETAILS - 2

CG106 GRADING DETAILS - 3

CG201 WALL A PROFILES

CG201A WALL A PROFILES, OPTION

CG202 WALL B PROFILES

CG203 SITE SECTIONS - 1

CG203A SITE SECTION - 1, OPTION

CG204 SITE SECTIONS - 2

CG205 SITE SECTIONS - 3

CG206 SITE SECTIONS - 4

CU101 OVERALL UTILITY PLAN

CU102 UTILITY PLAN - 1

CU103 UTILITY PLAN - 2

CU104 DRAIN LINE PLAN - 1

CU104A DRAIN LINE PLAN - 1, OPTION

CU105 DRAIN LINE PLAN - 2

CU201 UTILITY PROFILE - 1

CU202 UTILITY PROFILE - 2

CU203 UTILITY PROFILE - 3

CU204 UTILITY PROFILE - 4

CU205 UTILITY PROFILE - 5

CU206 UTILITY PROFILE - 6

CU207 UTILITY PROFILE - 7

CU208 UTILITY PROFILE - 8

CU501 TRENCH AND WATER DETAILS

CU502 WATER DETAILS - 1

CU503 WATER DETAILS - 2

CU504 WATER DETAILS - 3

CU505 SEWER DETAILS - 1

CU506 SEWER DETAILS - 2

CU507 DRAIN DETAILS - 1

CU508 DRAIN DETAILS - 2

CU509 DRAIN DETAILS - 3

CU510 DRAIN DETAILS - 4

SHEET COUNT: 64

LANDSCAPE

LD101 TREE DISPOSITION PLAN

L-001 LANDSCAPE SCHEDULE & NOTES

L-001A LANDSCAPE SCHEDULE & NOTES (OPTION)

L-002 IRRIGATION SCHEDULE & NOTES

L-002A IRRIGATION SCHEDULE & NOTES (OPTION)

L-003 IRRIGATION WATERING SCHEDULE & NOTES

L-003A IRRIGATION WATERING SCHEDULE & NOTES (OPTION)

L-101 OVERALL LANDSCAPE SITE PLAN

L-101A OVERALL LANDSCAPE SITE PLAN (OPTION)

L-102 LANDSCAPE SITE PLAN - 1

L-102A LANDSCAPE SITE PLAN - 1 (OPTION)

L-103 LANDSCAPE SITE PLAN - 2

L-104 IRRIGATION SITE PLAN - 1

L-104A IRRIGATION SITE PLAN - 1 (OPTION)

L-105 IRRIGATION SITE PLAN - 2

L-401 PLAYGROUND A PLAN

L-402 PLAYGROUND B PLAN

L-403 PLAYGROUND C PLAN

L-501 PLANTING DETAILS

L-502 LANDSCAPE DETAILS

L-503 PLAYGROUND A DETAILS

L-504 PLAYGROUND B DETAILS

L-505 PLAYGROUND C DETAILS

L-506 IRRIGATION DETAILS

L-507 IRRIGATION DETAILS

L-508 IRRIGATION DETAILS

L-509 IRRIGATION DETAILS

L-901 PLAYGROUND A 3D RENDERS

L-902 PLAYGROUND B 3D RENDERS

L-903 PLAYGROUND C 3D RENDERS

SHEET COUNT: 30

SHEET I.D. SHEET TITLE REVISION

STRUCTURAL

S-001 GENERAL STRUCTURAL NOTES

S-002 GENERAL STRUCTURAL NOTES

S-101 STRUCTURAL SITE PLAN WITH AT/FP

S-101A STRUCTURAL SITE PLAN WITH AT/FP

S-102 OVERALL FOUNDATION / SLAB PLAN

S-103 OVERALL ROOF FRAMING PLAN

S-104 FOUNDATION PLAN - AREA A & B

S-105 FOUNDATION PLAN - AREA C, D, & E

S-106 ROOF FRAMING PLAN - AREA A & B

S-107 ROOF FRAMING PLAN - AREA C, D, & E

S-201 STRUCTURAL ELEVATIONS

S-202 STRUCTURAL ELEVATIONS

S-301 BUILDING SECTIONS

S-302 BUILDING SECTIONS

S-304 SITE WALL SECTIONS

S-304A SITE WALL SECTIONS

S-305 RETAINING WALL ELEVATIONS

S-305A RETAINING WALL ELEVATIONS

S-306 RETAINING WALL ELEVATIONS

S-501 SECTIONS AND DETAILS

S-502 SECTIONS AND DETAILS

S-503 SECTIONS AND DETAILS

S-504 SECTIONS AND DETAILS

S-505 SECTIONS AND DETAILS

S-506 SECTIONS AND DETAILS

S-507 SECTIONS AND DETAILS

S-508 SECTIONS AND DETAILS

S-509 SECTIONS AND DETAILS

S-601 TYPICAL FOUNDATION DETAILS

S-602 TYPICAL SLAB-ON-GRADE DETAILS

S-603 TYPICAL CMU DETAILS

S-604 TYPICAL STRUCTURAL STEEL AND METAL DECK DETAILS

S-605 TYPICAL STEEL TRUSS DETAILS

S-606 TYPICAL RETAINING WALL DETAILS

S-607 TYPICAL RETAINING WALL SCHEDULE

S-608 TYPICAL RETAINING WALL SCHEDULE

S-611 TYPICAL RETAINING WALL SCHEDULE

S-612 TYPICAL RETAINING WALL DETAILS

S-613 RETAINING WALL PLANS AND SECTIONS

SHEET COUNT: 39

SHEET I.D. SHEET TITLE REVISION

ARCHITECTURAL

A-001 GENERAL NOTES, SYMBOLS AND ABBREVIATIONS

A-002 OVERALL SITE PLAN

A-002A OVERALL SITE PLAN (OPTION)

A-101 OVERALL FLOOR PLAN

A-102 PARTIAL FLOOR PLAN - AREA A

A-103 PARTIAL FLOOR PLAN - AREA B

A-104 PARTIAL FLOOR PLAN - AREA C

A-105 PARTIAL FLOOR PLAN - AREA D

A-106 PARTIAL FLOOR PLAN - AREA E

A-107 PARTIAL FLOOR PLAN - AREA F

A-108 PARTIAL FLOOR PLAN - AREA G

A-109 PARTIAL FLOOR PLAN - AREA H

A-110 PARTIAL FLOOR PLAN - AREA J

A-121 OVERALL REFLECTED CEILING PLAN

A-122 PARTIAL RCP - AREA A

A-123 PARTIAL RCP - AREA B

A-124 PARTIAL RCP - AREA C

A-125 PARTIAL RCP - AREA D

A-126 PARTIAL RCP - AREA E

A-127 PARTIAL RCP - AREA F

A-128 PARTIAL RCP - AREA G

A-129 PARTIAL RCP - AREA H

A-130 PARTIAL RCP - AREA J

A-141 OVERALL ROOF PLAN

A-142 OVERALL ROOF PLAN (OPTION)

A-201 EAST AND WEST EXTERIOR ELEVATIONS

A-202 NORTH AND SOUTH EXTERIOR ELEVATIONS

A-301 BUILDING SECTIONS

A-302 BUILDING SECTIONS

A-311 TYPICAL WALL SECTIONS

A-312 TYPICAL WALL SECTIONS (OPTION)

A-401 ENLARGED TOILET PLANS & ELEVATIONS

A-402 ENLARGED TOILET PLANS & ELEVATIONS

A-403 ENLARGED TOILET PLANS & ELEVATIONS

A-404 TOILET PARTITION ELEVATION DETAILS

A-411 INTERIOR ELEVATIONS

A-412 INTERIOR ELEVATIONS

A-413 INTERIOR ELEVATIONS

A-414 INTERIOR ELEVATIONS

A-415 INTERIOR ELEVATIONS

A-416 INTERIOR ELEVATIONS

A-417 INTERIOR ELEVATIONS

A-501 DETAILS - ROOF

A-502 DETAILS - ROOF

A-503 ENTRY CANOPY PLANS, ELEVATIONS, & SECTIONS

A-504 TRASH / RECYCLABLE PLAN, EXTERIOR ELEVATIONS & SECTION

A-505 DETAILS - EXTERIOR

A-511 PARTITION TYPES SCHEDULE

A-512 DETAILS - INTERIOR

A-513 DETAILS - INTERIOR

A-514 DETAILS - CEILING

A-521 DETAILS - DIAPER CHANGING STATION

A-522 DETAILS - RECEPTION DESK

A-523 DETAILS - CASEWORK

A-601 DOOR SCHEDULE & TYPES

A-602 DOOR DETAILS

A-603 DOOR DETAILS

A-611 WINDOW SCHEDULE, TYPES & DETAILS

AF701 INTERIOR ROOM FINISH SCHEDULE

AF702 FINISH MATERIAL SCHEDULE

AF703 OVERALL INTERIOR FLOOR FINISH & FF&E PLAN

AG701 OVERALL SIGNAGE PLAN

AG702 SIGNAGE SCHEDULE

AG703 SIGNAGE DETAILS

AJ701 OVERALL FLOOR PLAN - AIR BARRIER

AJ702 BUILDING SECTIONS - AIR BARRIER

SHEET COUNT: 66

KITCHEN EQUIPMENT

IF001 KITCHEN EQUIPMENT NOTES & LEGENDS

IF101 PARTIAL KITCHEN EQUIPMENT PLAN & EQUIPMENT SCHEDULE

IF102 PARTIAL KITCHEN EQUIPMENT ELECTRICAL PLAN & SCHEDULE

IF103 PARTIAL KITCHEN EQUIPMENT MECHNIICAL PLAN & SCHEDULE

IF104 KITCHEN EQUIPMENT BUILDING WORK & REFRIGERATION PLAN

IF301 KITCHEN EQUIPMENT ELEVATIONS & SECTIONS

IF302 KITCHEN EQUIPMENT ELEVATIONS & SECTIONS

IF501 KITCHEN EQUIPMENT BUILDING WORK DETAILS - 1

IF502 KITCHEN EQUIPMENT BUILDING WORK DETAILS - 2

IF503 KITCHEN EQUIPMENT BUILDING WORK DETAILS

IF504 KITCHEN EQUIPMENT WALK-IN DETAILS

IF601 KITCHEN EQUIPMENT HOOD FIRE SUPPRESSION DIAGRAM & NOTES

SHEET COUNT: 12

SHEET I.D. SHEET TITLE REVISION

FIRE PROTECTION

F-001 BUILDING CODE SUMMARY

F-002 CODE COMPLIANCE SITE PLAN

F-003 FIRE PROTECTION NOTES, SYMBOLS AND ABBREVIATIONS

F-101 FLOOR PLAN - LIFE SAFETY

FX101 FLOOR PLAN AREA AB - FIRE SPRINKLER

FX102 FLOOR PLAN AREA CF - FIRE SPRINKLER

FX103 FLOOR PLAN AREA DE - FIRE SPRINKLER

FX104 FLOOR PLAN AREA GHJ - FIRE SPRINKLER

FX501 FIRE SPRINKLER DETAILS

FA101 FLOOR PLAN AREA AB - FIRE ALARM/MASS NOTIFICATION

FA102 FLOOR PLAN AREA CF - FIRE ALARM/MASS NOTIFICATION

FA103 FLOOR PLAN AREA DE - FIRE ALARM/MASS NOTIFICATION

FA104 FLOOR PLAN AREA GHJ - FIRE ALARM/MASS NOTIFICATION

FA501 FIRE ALARM/MASS NOTIFICATION DETAILS

FA601 FIRE ALARM/MASS NOTIFICATION SEQUENCE OF OPERATIONS

FA602 FIRE ALARM/MASS NOTIFICATION RISER DIAGRAM

FA603 FIRE ALARM/MASS NOTIFICATION RISER DIAGRAM

SHEET COUNT: 17

PLUMBING

P-001 PLUMBING NOTES AND LEGEND

P-101 OVERALL PLUMBING PLAN

P-102 PARTIAL PLUMBING PLAN

P-103 PARTIAL PLUMBING PLAN

P-104 PARTIAL PLUMBING PLAN

P-105 PARTIAL PLUMBING PLAN

P-106 PARTIAL PLUMBING PLAN

P-107 PARTIAL PLUMBING PLAN

P-108 PARTIAL PLUMBING PLAN

P-109 PARTIAL PLUMBING PLAN

P-110 PARTIAL PLUMBING PLAN

P-121 OVERALL CDC BUILDING PLUMBING ROOF PLAN

P-501 PLUMBING DETAILS

P-502 PLUMBING DETAILS

P-503 PLUMBING DETAILS

P-504 PLUMBING DETAILS

P-601 SANITARY PIPING DIAGRAM

P-602 SANITARY PIPING DIAGRAM

P-603 SANITARY PIPING DIAGRAM

P-604 SANITARY PIPING DIAGRAM

P-605 SANITARY PIPING DIAGRAMS

P-606 WATER PIPING DIAGRAM

P-607 WATER PIPING DIAGRAM

P-608 WATER PIPING DIAGRAM

P-609 WATER PIPING DIAGRAM

P-610 WATER PIPING DIAGRAMS

P-651 PLUMBING SCHEDULES

P-652 PLUMBING SCHEDULES

SHEET COUNT: 28

MECHANICAL

M-001 MECHANICAL NOTES AND LEGEND

M-101 OVERALL MECHANICAL PLAN

M-102 PARTIAL MECHANICAL PLAN

M-103 PARTIAL MECHANICAL PLAN

M-104 PARTIAL MECHANICAL PLAN

M-105 PARTIAL MECHANICAL PLAN

M-106 PARTIAL MECHANICAL PLAN

M-107 PARTIAL MECHANICAL PLAN

M-108 PARTIAL MECHANICAL PLAN

M-109 PARTIAL MECHANICAL PLAN

M-110 PARTIAL MECHANICAL PLAN

M-121 OVERALL CDC BUILDING MECHANICAL ROOF PLAN

M-122 DUCT AIR LEAKAGE TEST PLAN

M-301 MECHANICAL SECTIONS

M-302 MECHANICAL SECTIONS

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-503 MECHANICAL DETAILS

M-504 MECHANICAL DETAILS

M-601 MECHANICAL SCHEDULES

M-602 MECHANICAL SCHEDULES

M-603 MECHANICAL SCHEDULES

M-604 MECHANICAL SCHEDULES

M-605 MECHANICAL SCHEDULES

M-610 CHILLED WATER PIPING DIAGRAMS

M-611 DX SPLIT FAN COIL UNIT DIAGRAMS

M-651 DDC POINTS LIST AND SEQUENCE OF OPERATIONS

M-652 DDC POINTS LIST AND SEQUENCE OF OPERATIONS

M-653 DDC SYSTEM ARCHITECTURE

M-654 CONTROL SCHEMATIC

SHEET COUNT: 30

SHEET I.D. SHEET TITLE REVISION

ELECTRICAL

E-001 ELECTRICAL SYMBOLS

E-002 ELECTRICAL ABBREVIATIONS

E-003 GENERAL ELECTRICAL NOTES

ES101 ELECTRICAL SITE PLAN - 1

ES101A ELECTRICAL SITE PLAN - OPTION A

ES102 ELECTRICAL SITE PLAN - 2

ES301 BUTTERFLY DIAGRAMS

ES501 ELECTRICAL DUCT DETAILS

EL101 LIGHTING PLAN - AREA A

EL102 LIGHTING PLAN - AREA B

EL103 LIGHTING PLAN - AREA C

EL104 LIGHTING PLAN - AREA D

EL105 LIGHTING PLAN - AREA E

EL501 LIGHTING SCHEDULE

EL502 LIGHTING DETAILS

EL601 LIGHTING CONTROL DIAGRAM

EP101 POWER PLAN - AREA A

EP102 POWER PLAN - AREA B

EP103 POWER PLAN - AREA C

EP104 POWER PLAN - AREA D

EP105 POWER PLAN - AREA E

EP106 POWER & LIGHTING PLAN - SUPPORT BUILDINGS

EP111 MECHANICAL POWER PLAN - AREA A

EP112 MECHANICAL POWER PLAN - AREA B

EP113 MECHANICAL POWER PLAN - AREA C

EP114 MECHANICAL POWER PLAN - AREA D

EP115 MECHANICAL POWER PLAN - AREA E

EP401 ENLARGED POWER PLAN - ELECTRICAL AND TELECOM ROOMS

EP501 PAD MOUNTED TRANSFORMER DETAILS

EP502 ELECTRICAL HH 4'x6' DETAIL

EP503 ELECTRICAL HANDHOLE & LIFT STATION PEDESTAL DETAILS

EP504 PAD MOUNTED SWITCH DETAILS

EP505 DISCONNECT STAND DETAIL

EP506 DIESEL GENERATOR DETAIL

EP601 ONE LINE DIAGRAM - 1

EP602 ONE LINE DIAGRAM - 2

EP611 PANEL SCHEDULES - 1

EP612 PANEL SCHEDULES - 2

EP613 PANEL SCHEDULES - 3

EP614 PANEL SCHEDULES - 4

EY001 SYSTEMS NOTES AND SUPPLEMENTAL LEGEND

EY101 SYSTEMS PLAN - AREA A

EY102 SYSTEMS PLAN - AREA B

EY103 SYSTEMS PLAN - AREA C

EY104 SYSTEMS PLAN - AREA D

EY105 SYSTEMS PLAN - AREA E

EY501 INTERCOM SYSTEM DETAILS & SYSTEM CONFIGURATION SCHEDULE

EY502 CLOSED CIRCUIT TELEVISION (CCTV) INFRASTRUCTURE DETAILS

EY601 CLOSED-CIRCUIT TELEVISION (CCTV) AND INTERCOM

INFRASTRUCTURE RISER DIAGRAM

SHEET COUNT: 49

TELECOMMUNICATIONS

T-001 TELECOMMUNICATIONS SYMBOLS, LEGEND, AND ABBREVIATIONS

T-002 TELECOMMUNICATIONS GENERAL NOTES

TD101 DEMOLITION TELECOM SITE PLAN

TS101 TELECOMMUNICATION SITE PLAN - 1

TS101A TELECOM SITE PLAN - OPTION A

T-101 TELECOM PLAN - AREA A

T-102 TELECOM PLAN - AREA B

T-103 TELECOM PLAN - AREA C

T-104 TELECOM PLAN - AREA D

T-105 TELECOM PLAN - AREA E

T-401 ENLARGED TELECOMMUNICATIONS PLANS

T-501 TELECOMMUNICATIONS DETAILS - 1

T-502 TELECOMMUNICATIONS DETAILS - 2

T-503 TELECOMMUNICATIONS DETAILS - 3

T-504 TELECOMMUNICATIONS DETAILS - 4

T-505 TELECOMMUNICATIONS DETAILS - 5

T-506 TELECOMMUNICATIONS DETAILS - 6

T-507 TELECOMMUNICATIONS DETAILS - 7

T-508 TELECOMMUNICATIONS DETAILS - 8

T-509 TELECOMMUNICATIONS DETAILS - 9

T-601 TELECOMMUNICATIONS RISER DIAGRAM

T-602 TELECOMMUNICATIONS GROUNDING DIAGRAM

T-603 CATV RISER DIAGRAM

SHEET COUNT: 23

TOTAL SHEET COUNT: 360

INDEX OF DRAWINGS

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E

E

E

E E

E E

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

139° 59' 16.89"

255.854

140° 13' 03.68"

381.639

US Army Corps of Engineers ®

SHEET ID

U S

A

R M

Y

C

O R

P

O

F

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

C T

N

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

J P

J P

D M

X X

F Y

H I L

D

D

E V

E L

O P

M E

N

T E

R

A L

I A

M A

M

I L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

A W

A I I

H O

N O

L U

L

D

S

T R

I C

T

B

U I L

D I N

G

F O

A

F T

E R

O

A H

U

H

A W

A I I

R E

G I O

N A

L

E

N G

I N

E E

R I N

G

C

E N

T E

R

H O

N O

L U

G

I N

E E

R I N

G

D

I S

T R

I C

T

H O

N O

L U

L U

H

A W

A I I

Y

DESIGN COMPLETE

V-001

E X

I S

T I N

G

C

O N

D I T

I O

N S

A1

EXISTING CONDITIONS

SCALE: 1"=40'

80'0 40'

SCALE : 1"=40'

EXIST. FENCE

STREET MONUMENT

BRASS PIN

N:72,423.76

E:1,671,966.96

ELEV: 299.82

H A

L A

W

V

E

W

L

O O

P

SASSAFRAS DRIVE

P

L

EXIST. FENCE

STREET MONUMENT TO STA. 13

STA. 13

"Y" CUT

N:72,717.04

E:1,671,722.76

ELEV: 263.74

STA. 19

MAG NAIL

N:72,980.66

E:1,671,612.40

ELEV: 241.96

STA. 21

MAG NAIL

N:73,114.43

E:1,671,815.96

ELEV: 252.38

STA. 14

IRON PIN

N:72,918.47

E:1,671,980.46

ELEV: 280.40

S

T

R

E

N

U

M

E

S

T

R

E

N

U

M

E

STA. 14 TO STA. 21

S

T

A

A

S T

A

T

O

S

T A

S

T

PLAN NORTH

SHEET ID

M

Y

C

O R

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

J P

J P

D M

X X

F Y

I L

D

D

E V

E L

O P

M E

N

T E

R

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

A W

A I I

H O

N O

L U

S

T R

I C

T

B

U I L

D I N

G

F O

A

F T

E R

O

A H

U

H

A W

A I I

R E

G I O

N A

L

E

N G

I N

E E

R I N

G

C

E N

T E

R

H O

N O

L U

G

I N

E E

R I N

G

D

I S

T R

I C

T

H O

N O

L U

L U

H

A W

A I I

DESIGN COMPLETE

BJ001

B O

R I N

G

L O

C A

T I O

N

P

L A

N

A1

BORING LOCATION PLAN

SCALE: 1"=40'

80'0 40'

SCALE : 1"=40'

SASSAFRAS DRIVE

PLAN NORTH

B1

B3

B2

B5/P2

B4/P1

B6/P3

B9

B8

B7

B10

B11

B12

GENERAL NOTES:

1. CLASSIFICATION OF SOILS, AS SHOWN ON THE BORING AND TEST PIT LOGS, ARE IN ACCORDANCE WITH

UNIFIED SOIL CLASSIFICATION SYSTEM (USCS).

2. BORING AND TEST PIT LOGS AND LOCATIONS ARE EXTRACTED FROM A GEOTECHNICAL REPORT ENTITLED:

GEOTECHNICAL INVESTIGATION

CHILD DEVELOPMENT CENTER

ALIAMANU MILITARY RESERVATION

HONOLULU, HAWAII

DATED JUNE 29, 2020

PERFORMED BY HIRATA & ASSOCIATES, INC

3. BORING LOGS ARE SHOWN ON SHEETS BJ002 TO BJ006. THE DATA REPRESENTS THE BEST SUBSURFACE

INFORMATION AVAILABLE. THE BORING LOGS DEPICT THE SUBSURFACE CONDITIONS ENCOUNTERED ONLY AT

THE SPECIFIC LOCATION AND AT THE TIME OF THE FIELD EXPLORATION INDICATED. VARIATIONS OF

SUBSURFACE CONDITIONS FROM THOSE DEPICTED IN THE LOGS MAY OCCUR BETWEEN AND BEYOND THE

BORINGS.

4. THE PENETRATION RESISTANCE SHOWN ON THE BORING LOGS IS SPECIFIC TO THEY TYPE OF SAMPLER

INDICATED. UNLESS AN SPT SAMPLER IS INDICATED ON THE LOGS, THE BLOW COUNTS ARE NOT STANDARD

PENETRATION TEST (SPT) BLOW COUNTS.

SHEET ID

M

Y

C

O R

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

J P

J P

D M

X X

F Y

I L

D

D

E V

E L

O P

M E

N

T E

R

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

A W

A I I

H O

N O

L U

S

T R

I C

T

B

U I L

D I N

G

F O

A

F T

E R

O

A H

U

H

A W

A I I

R E

G I O

N A

L

E

N G

I N

E E

R I N

G

C

E N

T E

R

H O

N O

L U

G

I N

E E

R I N

G

D

I S

T R

I C

T

H O

N O

L U

L U

H

A W

A I I

DESIGN COMPLETE

BJ002

B O

R I N

G

L O

G

SHEET ID

M

Y

C

O R

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

J P

J P

D M

X X

F Y

I L

D

D

E V

E L

O P

M E

N

T E

R

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

A W

A I I

H O

N O

L U

S

T R

I C

T

B

U I L

D I N

G

F O

A

F T

E R

O

A H

U

H

A W

A I I

R E

G I O

N A

L

E

N G

I N

E E

R I N

G

C

E N

T E

R

H O

N O

L U

G

I N

E E

R I N

G

D

I S

T R

I C

T

H O

N O

L U

L U

H

A W

A I I

DESIGN COMPLETE

BJ003

B O

R I N

G

L

O G

S

SHEET ID

M

Y

C

O R

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

J P

J P

D M

X X

F Y

I L

D

D

E V

E L

O P

M E

N

T E

R

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

A W

A I I

H O

N O

L U

S

T R

I C

T

B

U I L

D I N

G

F O

A

F T

E R

O

A H

U

H

A W

A I I

R E

G I O

N A

L

E

N G

I N

E E

R I N

G

C

E N

T E

R

H O

N O

L U

G

I N

E E

R I N

G

D

I S

T R

I C

T

H O

N O

L U

L U

H

A W

A I I

DESIGN COMPLETE

BJ004

B O

R I N

G

L

O G

S

SHEET ID

M

Y

C

O R

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

J P

J P

D M

X X

F Y

I L

D

D

E V

E L

O P

M E

N

T E

R

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

A W

A I I

H O

N O

L U

S

T R

I C

T

B

U I L

D I N

G

F O

A

F T

E R

O

A H

U

H

A W

A I I

R E

G I O

N A

L

E

N G

I N

E E

R I N

G

C

E N

T E

R

H O

N O

L U

G

I N

E E

R I N

G

D

I S

T R

I C

T

H O

N O

L U

L U

H

A W

A I I

DESIGN COMPLETE

BJ005

B O

R I N

G

L

O G

S

SHEET ID

M

Y

C

O R

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

J P

J P

D M

X X

F Y

I L

D

D

E V

E L

O P

M E

N

T E

R

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

A W

A I I

H O

N O

L U

S

T R

I C

T

B

U I L

D I N

G

F O

A

F T

E R

O

A H

U

H

A W

A I I

R E

G I O

N A

L

E

N G

I N

E E

R I N

G

C

E N

T E

R

H O

N O

L U

G

I N

E E

R I N

G

D

I S

T R

I C

T

H O

N O

L U

L U

H

A W

A I I

DESIGN COMPLETE

BJ006

B O

R I N

G

L O

G

SHEET ID

M

Y

C

O R

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

J P

J P

D M

X X

F Y

I L

D

D

E V

E L

O P

M E

N

T E

R

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

A W

A I I

H O

N O

L U

S

T R

I C

T

B

U I L

D I N

G

F O

A

F T

E R

O

A H

U

H

A W

A I I

R E

G I O

N A

L

E

N G

I N

E E

R I N

G

C

E N

T E

R

H O

N O

L U

G

I N

E E

R I N

G

D

I S

T R

I C

T

H O

N O

L U

L U

H

A W

A I I

DESIGN COMPLETE

C-001

N O

T E

S

CIVIL NOTES:

1. THE EXISTING TOPOGRAPHY AND LOCATIONS OF EXISTING STRUCTURES, UTILITIES, AND SITE

FEATURES AS SHOWN ON THE DRAWINGS ARE BASED ON A TOPOGRAPHIC SURVEY PERFORMED

BY CONTROL POINT SURVEY IN APRIL 2020 AND AVAILABLE RECORD DRAWINGS AND ARE NOT

GUARANTEED.

2. UNLESS OTHERWISE NOTED, OFFSET DIMENSIONS FROM THE BUILDING INDICATED ARE FROM THE

OUTSIDE FACE OF WALL. BUILDING LOCATIONS ARE WITH RESPECT TO OUTER WALL LINES.

3. THE CONTRACTOR SHALL OBTAIN AN EXCAVATION PERMIT FROM DPW PRIOR TO START OF ANY

EXCAVATION OR GRADING ACTIVITIES.

4. THE CONTRACTOR SHALL TONE AND PHYSICALLY VERIFY ALL CROSSINGS OF EXISTING UTILITIES

PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL ALSO VERIFY AND CHECK ALL

PERTINENT ELEVATION, LOCATION, AND DETAIL DIMENSIONS NOTED ON THE DRAWINGS PRIOR TO

PIPELINE UTILITY INSTALLATION. ANY DISCREPANCY WITH PLAN ARRANGEMENTS SHALL BE

IMMEDIATELY BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER OR THEIR

DESIGNATED REPRESENTATIVE FOR CLARIFICATION.

5. EXISTING STRUCTURES AND TREES NOT INDICATED ON THE PLANS FOR REMOVAL SHALL BE

PRESERVED. IF ANY SUCH STRUCTURES OR TREES OBSTRUCT CONSTRUCTION OPERATIONS, THE

CONTRACTING OFFICER OR THEIR DESIGNATED REPRESENTATIVE SHALL BE NOTIFIED BEFORE

PROCEEDING.

6. UTILITY SERVICES SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION. CONNECTION TO

UTILITIES SHALL BE DONE WITH THE MINIMUM AMOUNT OF DISRUPTION AND SHALL BE

COORDINATED WITH THE CONTRACTING OFFICER AND DPW. CONNECTION TO SANITARY SEWER

SYSTEMS SHALL BE COORDINATED WITH AQUA ENGINEERS.

7. ALL SERVICE CONNECTION OPERATIONS SHALL BE COORDINATED WITH THE CONTRACTING

OFFICER OR THEIR DESIGNATED REPRESENTATIVE. PRIOR TO COMMENCING WORK ON THE NEW

UTILITY LINES, THE CONTRACTOR SHALL:

A. EXCAVATE BY HAND OR CAREFULLY WITH MACHINERY TO VERIFY THE MATERIALS, O.D.,

LOCATION, AND DEPTH OF THE EXISTING UTILITY SERVICES AND STRUCTURES WHICH THE

NEW WORK WILL CROSS OR CONNECT TO. CARE SHALL BE EXERCISED DURING EXCAVATION

AND TRENCHING.

B. VERIFY THAT THE NEW WORK CAN BE INSTALLED AS SHOWN OR NOTIFY THE COR OF ANY

DISCREPANCIES WHICH WILL PREVENT INSTALLATION OF THE WORK AS SHOWN.

C. FOR THE NEW WATER LINE CONNECTION, ALL COMPONENTS, INCLUDING VALVES AND

RELATED ITEMS, SHALL BE ON SITE AND APPROVED PRIOR TO SCHEDULING OF UTILITY

CONNECTIONS.

8. THE CONTRACTOR SHALL TAKE THE NECESSARY PRECAUTIONS DURING CONSTRUCTION,

DEWATERING, AND EXCAVATION TO PREVENT DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR

SHALL BE HELD LIABLE IN THE EVENT OF ANY DAMAGE AND HELD RESPONSIBLE FOR THE

MAINTENANCE AND PROTECTION OF ALL EXISTING UTILITIES AND STRUCTURES SHOWN ON THE

DRAWINGS. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE MAINTENANCE AND

PROTECTION OF EXISTING UTILITIES AND STRUCTURES NOT SHOWN ON THE DRAWINGS BUT MADE

KNOWN TO HIM. REPAIR OF DAMAGE TO UTILITIES OR STRUCTURES NOT SHOWN ON THE

DRAWINGS SHALL BE ACCOMPLISHED BY THE CONTRACTOR IN ACCORDANCE WITH THE

SPECIFICATIONS AND WITH THE CONCURRENCE OF THE CONTRACTING OFFICER OR THEIR

DESIGNATED REPRESENTATIVE.

9. GOVERNMENT DISPOSAL AREA IS NOT AVAILABLE FOR DISPOSAL OF NON-HAZARDOUS WASTE

MATERIALS. THE CONTRACTOR SHALL DISPOSE ALL WASTE MATERIALS OUTSIDE THE

GOVERNMENT'S PROPERTY.

10. CONTRACTOR SHALL NOTIFY DPW AND AQUA ENGINEERS AT LEAST 45 DAYS PRIOR TO

CONNECTING TO OR COMMENCING WORK TO THE EXISTING WATER AND SEWER SYSTEMS.

11. PROTECT ALL EXISTING TREES NOT IDENTIFIED FOR REMOVAL DURING ALL PHASES OF

CONSTRUCTION. ANY TREE DAMAGED BY CONTRACTOR'S OPERATIONS SHALL BE REPLACED WITH

A TREE OF EQUAL SIZE AND SPECIES AT NO EXPENSE TO THE GOVERNMENT.

12. CONTRACTOR'S OPERATIONS AND STORAGE AREA (COSA) SHALL BE LOCATED AS INDICATED AND

COORDINATED WITH THE COR. COSA SHALL BE RESTORED TO ITS ORIGINAL CONDITION AFTER

PROJECT COMPLETION. COSA SHALL BE FENCED, AS DIRECTED BY THE COR, WITH A SIGN POSTED

SHOWING CONTRACTOR'S NAME, POINT OF CONTACT (POC), AND PHONE NUMBER FOR POC (24

HOURS/DAY), IN CASE OF AN EMERGENCY DURING OFF-HOURS.

13. PARKING FOR CONTRACTOR VEHICLES AND CONTRACTOR EMPLOYEE VEHICLES SHALL BE LIMITED

TO THE COSA AREA. CONTRACTOR AND CONTRACTOR EMPLOYEE VEHICLES WILL NOT BE

ALLOWED TO PARK ANYWHERE ELSE WITHIN THE BOUNDARIES OF ALIAMANU MILITARY

RESERVATION OR OTHER GOVERNMENT PROPERTY.

14. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND

APPROVALS REQUIRED FOR CONSTRUCTION OF THIS PROJECT AT NO ADDITIONAL COST TO THE

GOVERNMENT.

15. THE CONTRACTOR SHALL PERFORM MISCELLANEOUS SITE AND UTILITY DEMOLITION/REMOVAL

NOT SHOWN ON THE DRAWINGS WHERE NECESSARY TO ACCOMPLISH NEW CONSTRUCTION.

16. ALL UTILITY OUTAGES SHALL BE COORDINATED WITH THE CONTRACTING OFFICERS AT LEAST 45

DAYS PRIOR TO ANY OUTAGE. THE CONTRACTOR SHALL NOT MANIPULATE ANY SWITCHING

DEVICES OR VALVES AND SHALL NOTIFY THE FIRE DEPARTMENT PRIOR TO INSTALLING

TEMPORARY VALVES TO FIRE HYDRANT. PROVIDE A BACKFLOW PREVENTER WHEN CONNECTING

TO FIRE HYDRANTS FOR TEMPORARY USAGE. CONNECTION SHALL BE VIA QUICK

CONNECT/DISCONNECT COUPLINGS.

17. WHERE EXISTING UTILITIES NOT INDICATED FOR REMOVAL ARE ENCOUNTERED, INFORM THE

CONTRACTING OFFICER FOR FURTHER DIRECTION.

1. CONTRACTOR SHALL HIRE A LICENSED CIVIL ENGINEER WITH A MIN 5 YEARS TRAFFIC

CONTROL/ENGINEERIN DESIGN EXPERIENCE TO PREPARE TRAFFIC CONTROL AND PHASING PLANS

FOR ALL PROPOSED ROAD AND/OR PARKING LOT CLOSURES.

A. TRAFFIC CONTROL PLAN SHALL BE DONE IN ACCORDANCE WITH THE "MANUAL OF UNIFORM

TRAFFIC CONTROL DEVICES, PART 6 TEMPORARY TRAFFIC CONTROL" (LATEST EDITION) AND

TRAFFIC CONTROL PLAN NOTES ABOVE.

B. FOUR (4) COPIES OF CONTRACTOR PROPOSED TRAFFIC CONTROL & PHASING PLANS SHALL BE

SUBMITTED FOR GOVERNMENT APPROVAL IN ACCORDANCE WITH SPECIFICATION SECTION 01

33 00. SUBMITTAL AND APPROVAL OF TRAFFIC CONTROL PLANS SHALL BE OBTAINED IN

SUFFICIENT TIME TO ALLOW A MINIMUM OF 30 DAYS WRITTEN NOTICE TO THE CONTRACTING

OFFICER'S REPRESENTATIVE (COR) PRIOR TO CLOSURE OF ANY EXISTING ROAD/LANE AND/OR

EXISTING AC PAVEMENT PARKING LOT IN ACCORDANCE WITH SPECIFICATION SECTION 01 33 00.

C. CONTRACTOR'S TRAFFIC ENGINEER SHALL REVIEW AND APPROVE THE INSTALLATION OF

TRAFFIC CONTROL DEVICES TO BE USED FOR ROAD CLOSURE.

D. CONTRACTOR SHALL PREPARE, COORDINATE, AND OBTAIN A DPW TRAFFIC CONTROL PLAN

PERMIT PRIOR TO COMMENCING ANY ROAD/LANE CLOSURE ACTIVITIES ON THE INSTALLATION.

APPROVAL OF PROPOSED ROAD/LANE AND/OR PKG LOT CLOSURES SHALL BE OBTAINED FROM

DPW MASTER PLANNER AND OAHU BASE SUPPORT BTW (OBSB).

2. TRAFFIC CONTROL PLAN SHALL ENSURE THAT VEHICULAR AND PEDESTRIAN ACCESS IS

MAINTAINED AT ALL TIMES TO ALL EXISTING BUILDINGS.

3. ROAD/PARKING LOT CLOSURE REQUIREMENTS:

A. ONLY ONE SECTION OF ROADWAY SHALL BE ALLOWED TO BE CLOSED OFF AT ONE TIME FOR

PARKING LOT CONSTRUCTION WORK. (PROPOSED DETOUR ROUTES FOR ALL RD CLOSURES

SHALL BE SUBMITTED WITH THE CONTRACTOR'S TRAFFIC CONTROL PLAN. BOTH PLANS SHALL

BE APPROVED BY THE CONTRACTING OFFICER).

B. FOR ALL UTILITY AND OTHER WORK AFFECTING EXISTING ROADS (NOT OTHERWISE AFFECTED

BY CONSTRUCTION WORK): NO MORE THAN ONE BLOCK OF ROADWAY SHALL BE BLOCKED OFF

AT ONE TIME AND ONE LANE OF TRAFFIC SHALL BE MAINTAINED AT ALL TIMES. FLAGMEN SHALL

BE USED, AS REQUIRED, TO DIRECT TRAFFIC AROUND THE WORK SITE.

C. ALL ROADS AND PARKING LOTS REQUIRING CLOSURE TO FACILITATE CONSTRUCTION

OPERATIONS SHALL BE REOPENED AT THE END OF EACH WORK DAY.

4. THE CONTRACTOR SHALL OBTAIN ALL THE REQUIRED APPROVALS PRIOR TO START OF

CONSTRUCTION.

5. CONTRACTOR SHALL PROVIDE THE APPROPRIATE NUMBER OF FLAGMEN, EQUIPPED WITH THE

PROPER SAFETY CLOTHING, EQUIPMENT, AND/OR COMMUNICATION DEVICES TO CONDUCT,

CONTROL, AND MANAGE THE TRAFFIC ENTERING CONTRACTOR WORK SITE.

6. CONTRACTOR SHALL PROVIDE THE APPROPRIATE NUMBER OF ROAD SIGNS, I.E., ROAD CLOSED, DETOUR SIGNS, INFORMATION SIGNS OF UPCOMING AND/OR DURATION OF ROAD/LANE CLOSURE

SIGNS TO PROPERLY ADVISE AND REROUTE THE INCOMING TRAFFIC AWAY FROM THE

CONSTRUCTION SITE AND ALLOW FOR LOCAL TRAFFIC SERVICE INTO THE CONSTRUCTION AREAS.

7. CLOSURE OF MAJOR ROADWAYS, INTERSECTIONS, AND BASE ENTRANCES WILL REQUIRE THE

CONTRACTOR TO PROVIDE SEVERAL ELECTRONIC MESSAGE BOARDS SURROUNDING THE

CONSTRUCTION SITE AND SIGNS POSTED A MINIMUM OF 30 DAYS IN ADVANCE OF THE CLOSURE

WORK.

8. IN THE EVENT THE REQUESTED LANE/ROAD CLOSURE NEEDS TO BE EXTENDED DUE TO

UNFORESEEN WORK, ADVERSE WEATHER, ETC., THE CONTRACTOR SHALL SUBMIT IN WRITING A

MINIMUM TWO (2) WEEKS PRIOR TO THE PERMIT EXPIRATION DATE TO SEEK A PERMIT EXTENSION

FROM DPW TRAFFIC ENGINEER, KENNETH NAKASHIMA, (808)656-1965.

9. TRAFFIC CONTROL PERMIT SHALL BE RENEWED ONE YEAR FROM THE START DATE OF THE

PERFORMANCE PERIOD (POP), AND ANNUALLY THEREAFTER.

10. CONTRACTOR TRAFFIC CONTROL PROCEDURES SHALL INCORPORATE THE FOLLOWING:

A. A MINIMUM ROADWAY WIDTH OF 10 FEET SHALL BE OPEN AT ALL TIMES.

B. AT THE END OF EACH DAY'S WORK OR AS SOON AS THE WORK IS COMPLETED, THE

CONTRACTOR SHALL REMOVE ALL TRAFFIC CONTROL DEVICES NO LONGER NEEDED TO PERMIT

FREE AND SAFE PASSAGE OF PUBLIC TRAFFIC.

C. PROVIDE ADEQUATE, SAFE, NONSKID BRIDGING MATERIAL OVER TRENCHES IN PAVEMENT

AREAS TO HANDLE HS20-44 VEHICULAR TRAFFIC.

D. SAFE PEDESTRAIN TRAFFIC SHALL BE MAINTAINED AT ALL TIMES DURING THE CONSTRUCTION

PERIOD.

E. TRAFFIC CONTROL PLAN SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF MUTCD.

TRAFFIC CONTROL NOTES:

SEWER NOTES

1. FOR NEW AND EXISTING SEWER SYSTEMS OWNED BY THE ARMY, SEE SPECIFICATIONS AND THE BELOW

NOTES FOR AQUA ENGINEER SEWER SYSTEM REQUIREMENTS.

A. ALL SEWER CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH AQUA ENGINEERS, INC.

COLLECTION SYSTEM DESIGN AND CONSTRUCTION PROTOCOL, DATED JANUARY 2009, AQUA'S

IN-PLACE ABANDONMENT PROCEDURES, DATED AUGUST 2018, THE CITY AND COUNTY OF

HONOLULU'S STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, DATED SEPTEMBER

1986, STANDARD DETAILS FOR PUBLIC WORKS CONSTRUCTION, DATED SEPTEMBER 1984, AND

DESIGN STANDARDS OF THE DEPARTMENT OF WASTEWATER MANAGEMENT, VOLUME 1, DATED

JULY 1993.

B. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE AQUA ENGINEERS , INC. EMERGENCY PHONE

LINE AT (808) 685-7347 OF ANY WASTEWATER SPILLS. THE CONTRACTOR SHALL BE RESPONSIBLE

FOR ANY SEWAGE SPILLS CAUSED DURING CONSTRUCTION AND SHALL PAY FOR ANY COSTS

AND/OR FINES ASSOCIATED WITH ANY SEWAGE SPILL RESULTING FROM THE WORK AT NO COST TO

THE ARMY OR AQUA. CONTRACTOR SHALL REMEDIATE ANY SEWAGE SPILLS AS SOON AS POSSIBLE.

C. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING CONTINUOUS SEWER SERVICE TO ALL

AFFECTED AREAS DURING CONSTRUCTION.

D. CONTRACTOR SHALL BE RESPONSIBLE AND LIABLE FOR ALL WORK, INCLUDING OVERSIGHTS, DAMAGES, SPILLS, ERRORS, OR OMISSIONS CAUSED BY THE CONTRACTOR OR ANY OF ITS

SUBCONTRACTORS.

E. THE CONTRACTOR SHALL SUBMIT THE SEWER CONNECTION PERMIT (SCP) DURING CONSTRUCTION

TO AQUA ENGINEERS PRIOR TO ANY SEWER CONNECTIONS BEING MADE AND PLACED INTO

SERVICE.

F. CONTRACTOR SHALL SUBMIT A COMPLETED INSPECTION REQUEST (IR) FORM TO AQUA ENGINEERS

A MINIMUM OF 3 WORKING DAYS IN ADVANCE OF THE REQUESTED INSPECTION DATE.

G. ALL PERMITS, REQUESTS FOR INSPECTION, AND ANY OTHER SUBMITTALS SHALL BE SUBMITTED TO

PROJECTSERVICES@AQUAENGINEERS.COM

2. FOR EXISTING SEWER SYSTEMS THAT ARE OWNED BY THE NAVY, SEE BELOW NOTES FOR NAVAL

FACILITIES ENGINEERING COMMAND (NAVFAC) SEWER SYSTEM REQUIREMENTS.

A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING AND MAINTAINING ANY INCIDENTAL

SEWAGE BYPASS PUMPING OR DIVERSION WORK THAT WILL BE REQUIRED TO ACCOMPLISH THE

CONSTRUCTION WORK.

B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND MAINTAINING TEMPORARY POWER

AS NECESSARY TO MAINTAIN NORMAL LIFT STATION OPERATIONS.

C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ANY GOVERNMENT UTILITY SYSTEM

RESULTING FROM CONSTRUCTION OPERATIONS; ANY DAMAGE SHALL BE REPORTED IMMEDIATELY

TO THE CONTRACTING OFFICER OR APPROPRIATE GOVERNMENT REPRESENTATIVE. ANY SEWER

REPAIR PERFORMED BY THE CONTRACTOR SHALL BE INSPECTED BY THE NAVFAC HAWAII PW64 LINE

SECTION INSPECTOR PRIOR TO BACKFILLING.

D. THE CONTRACTOR WILL BE RESPONSIBLE FOR REGULATORY FINES OR PENALTIES THAT MAY BE

IMPOSED BY ENVIRONMENTAL REGULATORY AGENCIES (EPA AND/OR STATE DOH) IN THE EVENT OF

SEWAGE OVERFLOW OR SPILL RESULTING FROM CONSTRUCTION OPERATIONS.

E. THE CONTRACTOR SHALL REIMBURSE THE GOVERNMENT FOR ANY EMERGENCY RESPONSE

EFFORT THAT MAY BE REQUIRED BY GOVERNMENT FORCES TO MITIGATE THE ADVERSE EFFECTS

OF ANY SEWAGE OVERFLOW OR SPILL RESULTING FROM THE CONTRACTOR’S OPERATIONS.

F. ANY SEWER MANHOLE TO BE ABANDONED SHALL HAVE ITS CONE SECTION REMOVED AND

DISPOSED OF, PIPE PENETRATIONS PLUGGED WITH CLASS “C” (2000 PSI) CONCRETE AND THE

REMAINING RISER STRUCTURE BACKFILLED AND COMPACTED TO FINISH GRADE.

G. CLEANOUTS ON ANY ABANDONED SERVICE LATERAL SHALL BE PLUGGED AND TERMINATED A

MINIMUM OF 12 INCHES BELOW FINISH GRADE.

H. PRIOR TO ABANDONMENT, PIPE SHALL BE FILLED WITH FLOWABLE FILL AS NOTED.

I. THE CONTRACTOR SHALL CONTACT THE SUPERVISOR OF THE NAVFAC HAWAII PW64 LINE SECTION

(PHONE: 471-9850) TO MAKE ARRANGEMENTS FOR THE GOVERNMENT TO TAKE CUSTODY OF

SALVAGEABLE SEWER MANHOLE FRAMES AND COVERS. MANHOLE FRAMES AND COVERS NOT

ACCEPTED BY THE GOVERNMENT SHALL BE DISPOSED OF BY THE CONTRACTOR.

J. THE CONTRACTOR SHALL ENSURE THAT LOOSE MATERIAL, TOOLS AND EQUIPMENT FROM

CONSTRUCTION OPERATIONS ARE APPROPRIATELY REMOVED FROM THE SEWER COLLECTION

SYSTEM. ANY DAMAGE TO DOWNSTREAM LIFT STATION EQUIPMENT RESULTING FROM NEGLIGENCE

WILL BE ASSESSED TO THE CONTRACTOR.

K. CONSTRUCTION DEWATERING INTO THE NAVY’S SEWER COLLECTION SYSTEM IS PROHIBITED.

WATER NOTES

1. SEE SPECIFICATIONS FOR DPW WATER SYSTEM REQUIREMENTS.

2. WATER LINE PROFILES ARE SHOWN ON THE DRAWINGS FOR PIPE SIZES 3" AND LARGER. WHERE

ADJUSTMENTS OF WATER LINES ARE REQUIRED TO FIT FIELD CONDITIONS, THE ADJUSTMENTS SHALL

MEET THE FOLLOWING REQUIREMENTS.

A. MINIMUM COVER OF 3 FEET AND MAXIMUM COVER OF 8 FEET.

B. MINIMUM VERTICAL SEPARATION OF 12 INCHES TO EXISTING OR NEW PIPES, CONDUITS, OR DUCT

BANKS. USE CONTROL LOW STRENGTH MATERIAL BACKFILL WATER PIPE TRENCH WHERE THERE IS

LESS THAN 12 INCHES VERTICAL SEPARATION TO EXISTING OR NEW PIPES, CONDUITS, OR DUCT

BANKS.

SHEET ID

M

Y

C

O R

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

J P

J P

D M

X X

F Y

I L

D

D

E V

E L

O P

M E

N

T E

R

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

A W

A I I

H O

N O

L U

S

T R

I C

T

B

U I L

D I N

G

F O

A

F T

E R

O

A H

U

H

A W

A I I

R E

G I O

N A

L

E

N G

I N

E E

R I N

G

C

E N

T E

R

H O

N O

L U

G

I N

E E

R I N

G

D

I S

T R

I C

T

H O

N O

L U

L U

H

A W

A I I

DESIGN COMPLETE

C-002

N O

T E

S

L E

G E

N D

A

B B

R E

V I A

T I O

N S

SEWER

POLYVINYL CHLORIDE

VALVE BOXVB

WMH

WM

VERT.

W,WL

VERTICAL

WATER LINE

WATER METER

WATER MANHOLE

SHT.

TEL.

TYP.

SQ.

STA.

SMH

SCH

RET.

PVC

PAV'T.

SHEET

SQUARE

STATION

SEWER MANHOLE

TYPICAL

TELEPHONE

RETAINING

SCHEDULE

PAVEMENT

DET. DETAIL

ELECTRICAL MANHOLE

OUTSIDE DIAMETER

HB HOSE BIBB

OD

OC

MFR

MAX.

MIN.

MH

ID

INV.

HORIZ.

HV

MANHOLE

MANUFACTURER

MAXIMUM

ON CENTER

MINIMUM

HAND VALVE

HORIZONTAL

INSIDE DIAMETER

INVERT

GV

FF,FFE

EXIST.

FG

EMH

EL,ELEV.

E,ELEC

DWG.

DI

GATE VALVE

EXISTING

FINISH GRADE

FINISH FLOOR ELEVATION

ELECTRICAL

DRAWING

DIAMETER

DUCTILE IRON, DRAIN INLET

ELEVATION

ASPHALTIC CONCRETE

ABBREVIATIONS

CONT.

C

L

CV

CONC.

CONN.

CI

BLDG.

APPROX.

AC

CAST IRON

CONCRETE

CONTINUATION

CENTERLINE

CONNECTION

COVER

BUILDING

APPROXIMATE

T TOP

TS

BS BOTTOM OF SLAB OR SIDEWALK

FH FIRE HYDRANT

GAL. GALVANIZED

BC BOTTOM OF CURB

DMH DRAIN MANHOLE

PIV POST INDICATOR VALVE

DL DRAIN LINE

S, SAN

CB CATCH BASIN

LAT. LATERAL

MECH. MECHANICAL

DS DOWN SPOUT

EA. EACH

FT FEET

WV WATER VALVE

RPBP

ARCH. ARCHITECTURAL

STRUCT. STRUCTURAL

LP LAMP POLE

HP HIGH PRESSURE

TOP OF STEM, SLAB, OR SIDEWALK

DIA.,Ø

BFP BACKFLOW PREVENTER

COSA CONTRACTOR OPERATING AND STORAGE AREA

DPW DIRECTORATE OF PUBLIC WORKS

COR CONTRACTING OFFICER'S REPRESENTATIVE

MS4 MUNICIPAL SEPARATE

SS SANITARY SEWER

DSP DRY STANDPIPE

RSVD RESERVED

IPT IRON PIPE THREAD

TW

TOP OF WALL

EXISTING

LEGEND:

W

84.00 x

DIRECTION OF DRAINAGE

BUILDING OR STRUCTURE

WATERLINE, SIZE, AND GATE VALVE

SEWER LINE, SIZE, AND MANHOLE

CHAIN LINK FENCE

FIRE HYDRANT

DRAIN LINE, SIZE, CLEANOUT

SPOT ELEVATIONS

EDGE OF ROAD/PAV'T

CENTERLINE

CONCRETE CURB

CONTOURS

W

SAN

S6

W8

84.00

NEW

FIRE LINE, SIZE, AND GATE VALVE

GAS LINE, SIZE

F

F8

S

D

GAS

CONCRETE SIDEWALK

PRV PRESSURE RELEASE VALVE

CO,COTG CLEAN OUT, CLEAN OUT TO GRADE

BW BOTTOM OF WALL

CD CONDUIT

CMU CONCRETE MASONRY UNIT (HOLLOW TILE)

CL CHAIN LINK

D DRAIN

G GROUND

GW GUY WIRE

H HEIGHT

RPM RAISED PAVEMENT MARKER

TC TOP OF CURB

UP

UTILITY POLE / (POLE MOUNT)

SEWER LINE, STREET LIGHTSL

PE PLAIN END

EG EXISTING GRADE

SD

D18

G2

SURVEY NOTES:

1. RESTORE AND ESTABLISH ALL SURVEY MONUMENTS DISTURBED, DAMAGED, OR IMPACTED

BY DEMOLITION OR CONSTRUCTION.

2. TOPOGRAPHIC SURVEY IS BASED ON THE FOLLOWING:

3. AZIMUTHS SHOWN ON SHEET V-001 ARE MEASURED CLOCKWISE FROM THE SOUTH

4. SURVEY CONDUCTED BY:

5. LOCATION OF EXISTING MAINS AND SERVICE LATERAL LINES OR WATER, ELECTRICAL AND

COMMUNICATION SYSTEMS SHOWN IN THE SURVEY MAP ARE APPROXIMATE BASED ON BEST

AVAILABLE INFORMATION PROVIDED BY OTHERS.

6. ALL DIMENSIONS SHOWN ARE IN FEET UNLESS OTHERWISE NOTED.

HORIZONTAL PROJECTION: STATE PLANE ZONE 3 US SURVEY FT

HORIZONTAL DATUM: NAD83 (PA11)

GEODETIC VERTICAL DATUM: MSL, OAHU

BENCH MARKS:

1. SEE SHEETS V-001 FOR BENCHMARKS.

2. ALL HORIZONTAL AND VERTICAL CONTROLS FOR CONSTRUCTION SHALL BE

ESTABLISHED USING THE BENCHMARKS INDICATED ON SHEET V-001

STORM SEWER SYSTEM

REDUCED PRESSURE

BACKFLOW PREVENTER

SFM SEWER FORCE MAIN

CONTROLPOINT SURVEYING INC.

615 PIIKOI ST. SUITE 700

HONOLULU, HI, 96814

THK. THICKNESS

GRADING NOTES:

1. ALL NEW GRADES ARE FINISHED GRADES AT PAVEMENT SURFACE OR GROUND SURFACE.

2. THE LIMITS OF THE AREA TO BE GRADED SHALL BE FLAGGED BEFORE THE COMMENCEMENT

OF GRADING WORK.

3. THE CONTRACTOR, AT HIS OWN EXPENSE, SHALL KEEP THE PROJECT AREA AND

SURROUNDING AREA FREE FROM DUST NUISANCE. THE WORK SHALL BE IN CONFORMANCE

WITH THE LOCAL AND FEDERAL AIR POLLUTION CONTROL STANDARDS AND REGULATIONS.

4. ALL GRADING OPERATIONS SHALL BE PERFORMED IN CONFORMANCE WITH THE APPLICABLE

PROVISIONS OF THE STATE WATER POLLUTION CONTROL AND WATER QUALITY STANDARDS.

RUNOFF FROM THE SITE SHALL BE CONTAINED WHERE PRACTICAL. EROSION CONTROL

MEASURES (I.E. SILT FENCE, COMPOST FILTER SOCK, SNAKE BAG, ROCK CHECK DAMS, ETC.)

SHALL BE INSTALLED IN THE PATH OF SURFACE WATER RUNOFF TO TRAP SEDIMENTS.

5. ALL SLOPES AND EXPOSED AREAS OUTSIDE OF THE PAVEMENT AND BUILDING AREAS SHALL

BE PLANTED IMMEDIATELY AFTER THE GRADING WORK HAS BEEN COMPLETED.

6. THE CONTRACTOR SHALL REMOVE ALL SILT AND DEBRIS DEPOSITED IN DRAINAGE AND

SEWERAGE FACILITIES, ROADWAYS, AND OTHER AREAS RESULTING FROM HIS WORK. THE

COSTS INCURRED FOR ANY NECESSARY REMEDIAL ACTION BY THE CONTRACTING OFFICER

OR THEIR DESIGNATED REPRESENTATIVE SHALL BE PAYABLE AT THE CONTRACTOR'S

EXPENSE. SOIL TRACKING ONTO INSTALLATION ROADS IS PROHIBITED. WASHING OF SOIL

INTO STORM DRAIN INLETS IS PROHIBITED AND IS A VIOLATION OF THE CLEAN WATER ACT.

7. IMPLEMENT EROSION CONTROLS AND BEST MANAGEMENT PRACTICES (BMP) PLAN PRIOR TO

STARTING SITE DEMOLITION IN ACCORDANCE WITH CONTRACTOR'S PROJECT-SPECIFIC

STORM WATER POLLUTION PREVENTION PLAN (SWPPP). SEE SHEET C-003 FOR DETAILS.

DPW TREE CUTTING NOTES:

1. PER THE USAG-HI TREE CUTTING MORATORIUM DATED 20 JANUARY, 2017 AND TO COMPLY WITH

THE ENDANGERED SPECIES ACT, THE FOLLOWING MEASURES SHALL BE IMPLEMENTED.

A. DURING THE HAWAIIAN HOARY BAT (LASIURUS CINEREUS SEMOTUS) PUPPING SEASON, 1 JUNE

TO 15 SEPTEMBER, THERE SHALL BE NO CUTTING OR TRIMMING OF ANY TREE OVER 15 FEET

TALL.

B. IF A TREE FALLS ON ITS OWN THAT IS OVER 15 FEET TALL, YOU MAY REMOVE THE TREE.

C. IN CASE OF AN EMERGENCY SITUATION, E.G., A TREE LARGER THAN 15 FEET TALL IS

THREATENING A POWER LINE, THE STAFF MUST CONTACT THE DPW ENVIRONMENTAL DIVISION

AT 655-9189 FOR GUIDANCE PRIOR TO CUTTING THE TREE

SEWER FORCE MAIN, SIZE

SS

SFM3

SFSF

F

S

F

S

F

S

F

S

F

S

F

S

F

S

F

S

F

S

F

S

F

S

F

S

F

S

F

S F

S F

S

F

S

F

US Army Corps of Engineers ®

SHEET ID

M

Y

C

O R

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

J P

J P

D M

X X

F Y

I L

D

D

E V

E L

O P

M E

N

T E

R

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

A W

A I I

H O

N O

L U

S

T R

I C

T

B

U I L

D I N

G

F O

A

F T

E R

O

A H

U

H

A W

A I I

R E

G I O

N A

L

E

N G

I N

E E

R I N

G

C

E N

T E

R

H O

N O

L U

G

I N

E E

R I N

G

D

I S

T R

I C

T

H O

N O

L U

L U

H

A W

A I I

DESIGN COMPLETE

C-003

E R

O S

I O

N

C

O N

T R

A

N

A1

EROSION CONTROL PLAN

SCALE: 1"=40'

80'0 40'

SCALE : 1"=40'

STABILIZED

CONSTRUCTION

ENTRANCE

SILT FENCE (TYP.)

EXIST. FENCE (TYP.)

CATCH BASIN

INLET PROTECTION

H A

L A

E

W

L

O O

P

SASSAFRAS DRIVE

A8

C-004

A4

C-004

D4

C-004

CDC BLDG.

FOOTPRINT

PROJECT LIMITS

20'

10' HIGH DUST FENCE

CATCH BASIN

INLET PROTECTION

A4

C-004

CATCH BASIN

INLET PROTECTION

A4

C-004

DRAIN INLET

PROTECTION (TYP.)

SEE NOTE 1

E1

C-004

NOTES:

1. CONTRACTOR SHALL PROVIDE DRAIN INLET

PROTECTION FOR ALL DRAIN INLETS INSTALLED ON

THIS PROJECT. DRAIN INLET PROTECTION SHALL BE

REMOVED UPON COMPLETION OF THE PROJECT.

COMPOST FILTER

SOCK

A1

C-004

GRADING LIMITS

COMPOST FILTER

SOCK AROUND

TRENCH DRAIN

GRADING LIMITS

PLAN NORTH

STABILIZED

CONSTRUCTION

ENTRANCE

A1

C-004

M

I N

M

I N

LEGEND

PROJECT LIMITS

GRADING LIMITS

COMPOST FILTER SOCK

SF

SILT FENCE

PROJECT LIMITS

DRAIN INLET PROTECTION

DUST FENCE

GATE

DUST FENCE

GATE

DUST FENCE

FRONT

ELEVATION

2"X2" 14 GAGE

WIRE FABRIC OR

EQUIVALENT

FILTER FABRIC MATERIAL 60" WIDE ROLLS.

USE STAPLES OR WIRE RINGS TO ATTACH

FABRIC TO WIRE.

2"X4" WOOD POST BETTER OR EQUAL

ALTERNATE: STEEL FENCE POST

BURY BOTTOM OF

FILTER MATERIAL

6' MAX.

6"

2"X4"

WOODEN

STAKE @ 5'

O.C., MAX.

S L O

P E

LIMITS OF GRADING

2'-6"

(MIN.)

3/8"X3"X2' LONG WOOD BATTEN, NAILED

OR SCREWED TO EACH STAKE WITH

FASTERNERS @ 6" O.C.

SILT FENCE INSTALL PER MFR

RECOMMENDATION

MASS GRADE

BACKFILL TRENCH & COMPACT

GROUND (ONSITE MATERIAL)

NOT TO SCALE

SILT FENCE DETAIL

D4

GUTTER

GRAVEL FILLED

POUCH

CURB

INLET

EXIST. CATCH

BASIN

3" DIA. PERF. PVC PIPE

SEWN INSIDE

NOTES:

1. SEDIMENT CONTROL FILTERS SHALL BE CONSTRUCTED

AND MAINTAINED AT EXISTING CATCH BASINS AND

DRAIN INLETS INDICATED ON THE DRAWINGS.

2. THE CONTRACTOR SHALL REMOVE FILTERS AT TIMES

OF ABOVE NORMAL RAINFALL EVENTS AND REPLACE

THEM WHEN EVENT PASSES.

3. PERFORATED PVC PIPE SHALL BE SAW-CUT AT

INFLECTION POINTS WHERE GUTTER SLOPE CHANGES.

BEND PIPE TO CONFORM TO THE GUTTER SLOPE SUCH

THAT THERE ARE NO GAP BETWEEN GUTTER SURFACE

AND PIPE.

SEDIMENT FILTER

NOT TO SCALE

CATCH BASIN INLET PROTECTION DETAIL

A4

APPLICATIONS:

1. ALL POINTS OF CONSTRUCTION INGRESS AND EGRESS.

2. UNPAVED AREAS WHERE SEDIMENT TRACKING OCCURS FROM SITE ONTO PAVED ROADS.

INSTALLATION / APPLICATION CRITERIA:

1. CONSTRUCT ON LEVEL GROUND WHERE POSSIBLE.

2. STONES SHOULD BE 3"-6" COARSE AGGREGATE.

3. MINIMUM DEPTH OF STONES SHOULD BE 8".

4. LENGTH SHOULD BE 50' MIN., AND COVERED THE ENTIRE WIDTH.

5. PROVIDE AMPLE TURNING RADII AS PART OF ENTRANCE.

6. PROVIDE ADEQUATE PROTECTION FOR ANY UNDERGROUND UTILITIES.

MAINTENANCE REQUIREMENTS:

1. INSPECT WEEKLY AND AFTER EACH RAINFALL OF 0.25 INCH AND GREATER IN A 24-HOUR PERIOD.

2. REPLACE GRAVEL MATERIAL WHEN SURFACE VOIDS ARE VISIBLE.

3. REMOVE ALL SEDIMENT DEPOSITED ON PAVED ROADWAYS WITHIN 24 HOURS.

4. REMOVE GRAVEL AND FILTER FABRIC AT COMPLETION OF CONSTRUCTION.

H

A

R

F

A

C

E

P

U

B

L

A

D

FILTER FABRIC

SEE SPEC

SECTION 31 05 19

3"-6"

COARSE

AGGREGATE

M

I N

S

A

N

S

M

I N

R

T

Y

P

SILT

FENCE

NOT TO SCALE

STABILIZED CONSTRUCTION ENTRANCE DETAIL

A1

COMPOST FILTER

SOCK, TYP

PLAN

STAKE ANCHOR,

(TYP) SEE NOTE 3

6" MIN

OVERLAP

RUNOFF

FLOW

COMPOST FILTER SOCK

8" MINIMUM DIAMETER

SECTION

M I N

M A

X

WORK AREA

RUNOFF FLOW

STAKE ANCHOR WHERE REQUIRED

SEE NOTES 3 AND 4, TYP

SEE PLANS FOR DOWNSTREAM

LOCATIONS OF RUNOFF FLOW

FILTER SOCK NOTES:

1. COMPOST SHALL NOT CONTAIN BIOSOLIDS.

2. REMOVE SEDIMENT FROM THE UP SLOPE SIDE OF THE COMPOST FILTER SOCK

WHEN ACCUMULATION HAS REACHED 1/3 OF THE EFFECTIVE HEIGHT.

3. 3/4"x3/4"x16" MINIMUM WOODEN STAKE ANCHOR. FOR PAVEMENT AREAS USE

SAND BAGS (18"x12"x3" MIN) IN PLACE OF STAKES.

4. ON < 4H:1V SLOPE, NO STAKE ANCHOR REQUIRED.

ON 4H:1V TO 3H:1V SLOPE, STAKE AT 10 FT ON CENTER.

ON 3H:1V TO 2H:1V SLOPE, STAKE AT 5 FT TO 10 FT ON CENTER.

ON > 2H:1V SLOPE, STAKE AT 5 FT ON CENTER, STAKES ON WORK AREA SIDE

SHALL BE INSTALLED IN CENTER OF COMPOST FILTER SOCK.

WORK AREA

STAKE ANCHOR

SPACING SEE NOTE 4

ON > 2H:1V SLOPE STAKE ON

WORK AREA SIDE TO BE

INSTALLED IN CENTER OF

COMPOST FILTER SOCK

NOT TO SCALE

COMPOST FILTER SOCK

A8

SEE PLANS FOR

DOWNSTREAM LOCATIONS

OF RUNOFF FLOW

GRATE

FILTER FABRIC

SEE SPEC

SECTION 31 05 19

DRAIN INLET

SECURE FILTER

FABRIC TO GRATE

NOT TO SCALE

DRAIN INLET PROTECTION

E1

FILTER SOCK INLET

PROTECTION, TYP.,

SEE DET. E8, THIS SHEET

1' MIN

OVERLAP

RUNOFF

FLOW

RUNOFF

FLOW

FILTER SOCK, SEE

DET A8, THIS SHEET

NOTE:

DO NOT INSTALL FILTER

SOCK INLET PROTECTION IN

VEHICLE TRAFFIC AREAS

NOT TO SCALE

FILTER SOCK INLET PROTECTION

E8

US Army Corps of Engineers ®

SHEET ID

M

Y

C

O R

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

J P

J P

D M

X X

F Y

P

N

C

H I

V

E L O

P M

E N

T

C

E N

T E

R

A L I A

M A

L I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

A W

A I I

H O

N O

L U

S

T R

I C

T

B

U I L D

I N

G

F O

A

F T

E R

O

A H

U

H

A W

A I I

R E

G I O

N A

L

E

N G

I N

E E

R I N

G

C

E N

T E

R

H O

N O

L U

G

I N

E E

R I N

G

D

I S

T R

I C

T

H O

N O

L U

L U

H

A W

A I I

M

DESIGN COMPLETE

C-004

E R

O S

I O

N

C

O N

T R

T

A I

SHEET ID

M

Y

C

O R

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

J P

J P

D M

X X

F Y

I L

D

D

E V

E L

O P

M E

N

T E

R

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

A W

A I I

H O

N O

L U

S

T R

I C

T

B

U I L

D I N

G

F O

A

F T

E R

O

A H

U

H

A W

A I I

R E

G I O

N A

L

E

N G

I N

E E

R I N

G

C

E N

T E

R

H O

N O

L U

G

I N

E E

R I N

G

D

I S

T R

I C

T

H O

N O

L U

L U

H

A W

A I I

DESIGN COMPLETE

C-005

E R

O S

I O

N

C

O N

T R

T

E S

GOOD HOUSEKEEPING BMPS:

1. STREET SWEEPING AND VACUUMING. ALL POLLUTANTS DISCHARGED FROM

CONSTRUCTION SITE TO OFF-SITE AREAS MUST BE SWEPT OR VACUUMED EACH DAY

BEFORE LEAVING THE JOB SITE.

2. MATERIALS DELIVERY, STORAGE AND USE MANAGEMENT. PREVENT, REDUCE, OR

ELIMINATE THE DISCHARGE OF POLLUTANTS FROM MATERIAL DELIVERY, STORAGE, AND

USE TO THE STORM WATER SYSTEM OR WATERCOURSES BY MINIMIZING THE STORAGE OF

HAZARDOUS MATERIALS ONSITE, STORING MATERIALS IN A DESIGNATED AREA, INSTALLING

SECONDARY CONTAINMENT. CONSTRUCTION MATERIALS, WASTE, TOXIC AND HAZARDOUS

SUBSTANCES, STOCKPILES AND OTHER SOURCES OF POLLUTION SHALL NOT BE STORED IN

BUFFER AREAS, NEAR AREAS OF CONCENTRATED FLOW, OR AREAS ABUTTING THE

EXISTING MS4, RECEIVING WATERS, OR DRAINAGE IMPROVEMENTS THAT DISCHARGE

OFF-SITE. PRIMARY AND SECONDARY CONTAINMENT CONTROLS AND COVERS SHALL BE

IMPLEMENTED TO THE MAXIMUM EXTENT POSSIBLE.

3. SPILL PREVENTION AND CONTROL. CREATE AND IMPLEMENT SPILL PREVENTION AND

RESPONSE PLANS TO ELIMINATE AND MINIMIZE THE DISCHARGE OF POLLUTANTS TO THE

MS4 AND RECEIVING WATERS FROM LEAKS AND SPILLS BY REDUCING THE CHANCE FOR

SPILLS, ABSORBING, CONTAINING, AND CLEANING UP SPILLS AND PROPERLY DISPOSING OF

SPILL MATERIALS. AT A MINIMUM, ALL PROJECTS SHALL CLEANUP ALL LEAKS AND SPILLS

IMMEDIATELY.

4. HAZARDOUS MATERIALS. PREVENT OR REDUCE THE DISCHARGE OF POLLUTANTS TO

STORM WATER FROM HAZARDOUS WASTE THROUGH PROPER MATERIAL USE AND WASTE

DISPOSAL. IN THE EVENT THAT HAZARDOUS MATERIALS ARE DISCHARGED TO THE STORM

SEWER SYSTEM, IMMEDIATELY NOTIFY THE CONTRACTING OFFICER REPRESENTATIVE

(COR) OF THE DISCHARGE. A WRITTEN REPORT DESCRIBING THE POLLUTANTS THAT WERE

DISCHARGED, THE REASONS FOR THE DISCHARGE, AND THE MEASURES THAT HAVE BEEN

TAKEN OR WILL BE TAKEN TO PREVENT A REOCCURRENCE OF THE DISCHARGE SHALL BE

SUBMITTED TO THE COR NO LESS THAN 3 DAYS AFTER NOTIFICATION.

5. NONHAZARDOUS MATERIALS. IN THE EVENT THAT NONHAZARDOUS MATERIALS ARE

DISCHARGED TO THE STORM SEWER SYSTEM, NOTIFY THE COR NO LATER THAN THE NEXT

BUSINESS DAY. A WRITTEN REPORT DESCRIBING THE POLLUTANTS THAT WERE

DISCHARGED, THE REASONS FOR THE DISCHARGE, AND THE MEASURES THAT HAVE BEEN

TAKEN OR WILL BE TAKEN TO PREVENT A REOCCURRENCE OF THE DISCHARGE SHALL BE

SUBMITTED TO THE COR NO LESS THAN 3 DAYS AFTER NOTIFICATION.

6. VEHICLE AND EQUIPMENT CLEANING. ELIMINATE AND MINIMIZE THE DISCHARGE OF

POLLUTANTS TO STORM WATER FROM VEHICLE AND EQUIPMENT CLEANING OPERATIONS

BY USING OFF-SITE FACILITIES WHEN FEASIBLE, WASHING IN DESIGNATED, CONTAINED

AREAS ONLY, AND ELIMINATING DISCHARGES TO THE MS4 BY EVAPORATING AND/OR

TREATING WASH WATER, AS APPROPRIATE OR INFILTRATING WASH WATER FOR EXTERIOR

CLEANING ACTIVITIES THAT USE WATER ONLY.

7. VEHICLE AND EQUIPMENT FUELING. PREVENT FUEL SPILLS AND LEAKS BY USING OFF-SITE

FACILITIES, FUELING ONLY IN DESIGNATED AREAS, ENCLOSING OR COVERING STORED

FUEL, AND IMPLEMENTING SPILL CONTROLS SUCH AS SECONDARY CONTAINMENT AND

ACTIVE MEASURES USING SPILL RESPONSE KITS.

8. VEHICLE AND EQUIPMENT MAINTENANCE. ELIMINATE AND MINIMIZE THE DISCHARGE OF

POLLUTANTS TO STORM WATER FROM VEHICLE AND EQUIPMENT MAINTENANCE

OPERATIONS BY USING OFF-SITE FACILITIES WHEN FEASIBLE, PERFORMING WORK IN

DESIGNATED AREAS ONLY, USING SPILL PADS UNDER VEHICLES AND EQUIPMENT,

CHECKING FOR LEAKS AND SPILLS, AND CONTAINING AND CLEANING UP SPILLS

IMMEDIATELY.

9. SOLID WASTE MANAGEMENT. PREVENT OR REDUCE DISCHARGE OF POLLUTANTS TO THE

LAND, GROUNDWATER, AND IN STORM WATER FROM SOLID WASTE OR CONSTRUCTION

AND DEMOLITION WASTE BY PROVIDING DESIGNATED WASTE COLLECTION AREAS,

COLLECT SITE TRASH DAILY, AND ENSURING THAT CONSTRUCTION WASTE IS COLLECTED,

REMOVED, AND DISPOSED OF ONLY AT AUTHORIZED DISPOSAL AREAS.

10. SANITARY/SEPTIC WASTE MANAGEMENT. TEMPORARY AND PORTABLE SANITARY AND

SEPTIC WASTE SYSTEMS SHALL BE MOUNTED OR STAKED IN, WELL-MAINTAINED AND

SCHEDULED FOR REGULAR WASTE DISPOSAL AND SERVICING. SOURCES OF SANITARY

AND/OR SEPTIC WASTE SHALL NOT BE STORED NEAR THE MS4 OR RECEIVING WATERS.

11. STOCKPILE MANAGEMENT. STOCKPILES SHALL NOT BE LOCATED IN DRAINAGE WAYS, AND

WITHIN 50 FEET FROM AREAS OF CONCENTRATED FLOWS. COMPOST FILTER SOCK OR SILT

FENCES SHALL BE USED AROUND THE BASE OF ALL STOCKPILES. STOCKPILES SHALL NOT

EXCEED 15 FEET IN HEIGHT. STOCKPILES GREATER THAN 15 FEET IN HEIGHT SHALL

REQUIRE 8 FOOT WIDE BENCHING. STOCKPILES MUST BE COVERED WITH PLASTIC

SHEETING OR A COMPARABLE MATERIAL IF THEY WILL NOT BE ACTIVELY USED WITHIN 7

DAYS.

12. LIQUID WASTE MANAGEMENT. LIQUID WASTE SHALL BE CONTAINED IN A CONTROLLED

AREA SUCH AS A HOLDING PIT, SEDIMENT BASIN, ROLL-OFF BIN, OR PORTABLE TANK OF

SUFFICIENT VOLUME AND TO CONTAIN THE LIQUID WASTES GENERATED. CONTAINMENT

AREAS OR DEVICES MUST BE IMPERMEABLE AND LEAK FREE AND SHOULD NOT BE

LOCATED WHERE ACCIDENTAL RELEASE OF THE CONTAINED LIQUID CAN DISCHARGE TO

WATER BODIES, CHANNELS, OR STORM DRAINS.

RAIN RESPONSE PLAN:

1. THE FOLLOWING WILL BE PERFORMED WHEN HEAVY RAINS, TROPICAL STORM OR

HURRICANE IS IMMINENT OR IS FORECASTED IN THE NEXT 48 HOURS:

2. TEMPORARY SUSPENSION OF ACTIVE GRADING, GRUBBING AND TRENCHING.

3. INSPECT ALL SEDIMENT BASINS, TEMPORARY DITCHES/ SWALES, PERIMETER

CONTROLS, AND INLET PROTECTION DEVICES, AND MAINTAIN AS NEEDED. REINSTALL

ANY PERIMETER CONTROLS THAT WERE REMOVED DUE TO ACTIVE WORK IN THE

AREA. IF A SEVERE STORM IS EXPECTED, REMOVE INLET PROTECTION DEVICES TO

PREVENT FLOODING ON SURROUNDING STREETS.

4. COVER OR RELOCATE MATERIAL STOCKPILES AND LIQUID MATERIAL CONTAINERS TO

AVOID CONTACT WITH RAINWATER.

5. PLACE SPILL PANS OR OIL-ONLY SPILL PADS UNDER CONSTRUCTION VEHICLES TO

PREVENT RUNOFF FROM CONTACTING ANY SPILLED PETROLEUM PRODUCTS.

PROPERLY DISPOSE OF ANY ACCUMULATED OILY WATER AFTER THE RAIN EVENT.

6. RE-INSPECT AFTER THE APPROACHING HEAVY RAINS, TROPICAL STORM OR

H…

This is the start of the file's text. The full file is on GovTribe.