PM-1414_Pkg B - Connor Hall & Greenhouse Roof Replacement_Construction Drawings.pdf
PDF 3 MB Posted
- Solicitation number
- PM-1414
- Issued by
- Burleson County, Texas
About this file
This is a construction drawings document for West Texas A&M University's roof replacement project, prepared by Armko Industries, Inc., a Texas-registered engineering firm. The project encompasses multiple buildings located at 2501 4th Avenue, Canyon, Texas 79016, including Connor Hall and the Greenhouses, which are the focus of Package B. The drawings detail comprehensive roof replacement work including removal of existing roof systems, installation of new roofing membranes, insulation, flashings, metal accessories, and associated components. Connor Hall requires architectural composition shingles with removal of the existing shingle roof system down to the deck, new synthetic underlayment, prefinished metal gutters and downspouts, vented hip and ridge vents, and lead jacks at plumbing stacks. The Greenhouses require removal of existing polycarbonate panels and installation of a new polycarbonate roof system matching existing size and style specifications. The construction drawings include general roofing information, wind uplift pressure plans, overall roof plans, and detailed specifications for roof components, penetrations, flashing systems, and installation requirements. All work must be performed in accordance with NRCA, SMACNA, and ANSI/SPRI standards and manufacturer guidelines, with HVAC and electrical piping disconnect and reconnection services required.
The drawings specify a two-year contractor warranty on all work performed. New metal materials are to be prefinished and selected by the owner from a full range of colors. All gas lines must be tested and certified by a master plumber. The project includes wind uplift design criteria for shingle roof systems with specific fastening requirements and pressure zones indicated on the wind uplift pressure plans. The construction sequence and detailed specifications address critical elements including proper membrane installation, flashing details at all roof penetrations, tapered crickets for positive drainage around equipment, pipe and conduit supports, walk pads, safety railings, and fall protection screens. The drawings establish that contractors must verify all substrates, dimensions, curbs, and penetrations prior to commencing work, with typical conditions shown but not necessarily all-inclusive. A roof plaque identifying the roofing contractor, manufacturer, guarantee period, project information, and emergency contact details is required upon completion.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VICINITY MAP LOCATION MAP
NORTHNORTH
JOB:
DATE:
DRAWN BY:
TEXAS REGISTERED
ENGINEERING FIRM F-6498
2505 79TH ST., SUITE A
LUBBOCK, TEXAS 79423
(972) 874-1388
IN
D U
ST
R
IE
S, IN
C
ARMKO
CONTRACTOR SHALL VERIFY ALL
SUBSTRATES, DIMENSIONS,
CURBS, PENETRATIONS, ECT.
THOSE SHOWN ARE TYPICAL BUT
MAY NOT BE ALL INCLUSIVE
Copyright 2025 by Armko Industries
ISSUES
CHECKED BY:
THIS DOCUMENT WAS
PRODUCED BY OR UNDER
THE DIRECT SUPERVISION
OF REGISTERED ENGINEER
REVISIONS
ISSUE DATE:
Issue For Construction 10/07/2025
COVER SHEET
25-1183-49 01/20/2026
AA/JK
GS1.00
PR
O
JE
C
T
FO
R
W
ES
T
TE
XA
S
A& M
U N
IV
ER
SI
TY
R O
O F
R
EP
LA
C
EM
EN
T
PR
O
JE
C T
CB
01/20/2026
SHEET INDEX
Sheet Number Sheet Name
GS1.00 COVER SHEET
GS1.01 GENERAL ROOFING INFORMATION
GS2.00 WIND UPLIFT PRESSURE PLAN -
CLASSROOM CENTER & JACK B.
KELLY STUDENT CENTER
GS2.01A WIND UPLIFT PRESSURE PLAN -
PANHANDLE PLAINS HISTORICAL
MUSEUM
GS2.01B WIND UPLIFT PRESSURE PLAN -
PANHANDLE PLAINS HISTORICAL
MUSEUM
GS2.02 WIND UPLIFT PRESSURE PLAN -
CORNETTE LIBRARY
GS2.03 WIND UPLIFT PRESSURE PLAN -
GREENHOUSES
GS2.04 WIND UPLIFT PRESSURE PLAN -
CONNER HALL
R1.01 OVERALL ROOF PLAN -
CLASSROOM CENTER & JACK B.
KELLY STUDENT CENTER
R1.02 ENLARGED ROOF PLAN -
CLASSROOM CENTER
R1.03 ENLARGED ROOF PLAN - JACK B.
KELLY STUDENT CENTER
R1.04 OVERALL ROOF PLAN - CORNETTE
LIBRARY
R1.05 OVERALL ROOF PLAN - CONNER
HALL
R1.06 OVERALL ROOF PLAN -
GREENHOUSES
R1.07 OVERALL ROOF PLAN - PANHANDLE
PLAINS HISTORICAL MUSEUM
R2.01 ROOF DETAILS
R2.02 ROOF DETAILS
R2.03 ROOF DETAILS
R2.04 ROOF DETAILS
R2.05 ROOF DETAILS
WEST TEXAS A&M UNIVERSITY
ROOF REPLACEMENT PROJECT
MULTIPLE BUILDINGS
2501 4TH AVE,
CANYON, TEXAS 79016
M U
LT
IP
LE
B
U
IL
D
IN
G S
TH
A
VE
C
AN
YO
N , T
X
CLASSROOM CENTER & STUDENT CENTER
CONNER HALL
GREENHOUSES
CORNETTE LIBRARY
PANHANDLE PLAINS HISTORICAL MUSEUM
CONSTRUCTION
SEQUENCE
GLAZING
WINDOW FRAME
ADHERE SELF-ADH
FLASHING TO
SUBSTRATE, S.S.
BENT MTL & SIDE
OF WDW FRAME
TYP TERM BAR @ EDGE
OF SELF-ADH FLASHING
WALL SURFACE
WALL SURFACE
JOB:
DATE:
DRAWN BY:
TEXAS REGISTERED
ENGINEERING FIRM F-6498
2505 79TH ST., SUITE A
LUBBOCK, TEXAS 79423
(972) 874-1388
IN
D U
ST
R
IE
S, IN
C
ARMKO
CONTRACTOR SHALL VERIFY ALL
SUBSTRATES, DIMENSIONS,
CURBS, PENETRATIONS, ECT.
THOSE SHOWN ARE TYPICAL BUT
MAY NOT BE ALL INCLUSIVE
Copyright 2025 by Armko Industries
ISSUES
CHECKED BY:
THIS DOCUMENT WAS
PRODUCED BY OR UNDER
THE DIRECT SUPERVISION
OF REGISTERED ENGINEER
REVISIONS
ISSUE DATE:
Issue For Construction 10/07/2025
GENERAL ROOFING
INFORMATION
25-1183-49 10/07/2025
AA/JK
GS1.01
PR
O
JE
C
T
FO
R
W
ES
T
TE
XA
S
A& M
U N
IV
ER
SI
TY
R O
O F
R
EP
LA
C
EM
EN
T
PR
O
JE
C T
CB
01/20/2026
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
W.
X.
Y.
Z.
AA.
AB.
AC.
AD.
AE.
GENERAL ROOF NOTES:
PROVIDE ALL REQUIRED UTILITY / STRUCTURAL COMPONENTS AND/OR CONNECTIONS FOR
THE FUNCTIONAL USE OF ALL CONTRACTOR SUPPLIED EQUIPMENT OR APPLIANCES,
REGARDLESS OF ANY OMISSIONS OR INCONSISTENCIES ENCOUNTERED IN THE
CONSTRUCTION DOCUMENTS.
THE WORD 'PROVIDE' SHALL MEAN 'FURNISH AND INSTALL' COMPLETE AND READY TO USE.
IF DISCREPANCIES APPEAR BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE
HIGHER QUALITY, QUANTITY, AND PRICE SHALL SUPERSEDE.
THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL BECOME FAMILIAR WITH THE
PROJECT AND THE ON-SITE / OFF-SITE CONDITIONS PRIOR TO BIDDING OR COMMENCING
WORK.
PROVIDE METAL END CLOSURE ON EXPANSION JOINTS WHERE THEY OCCUR AT THE EDGE
OF THE ROOF.
ROOF SLOPES SHOWN ON DRAWINGS ARE GENERAL AND CONCEPTUAL ONLY. TAPER
INSULATION IS SHOWN CONCEPTUALLY AND FOR INTENT ONLY; NOT TO SCALE AND
SHOWN AS GRAPHIC REPRESENTATION ONLY TO SHOW SLOPE. INTENT IS TO PROVIDE
POSITIVE DRAINAGE TO ALL ROOF DRAINS, SCUPPERS, AND GUTTERS. VERIFY INSULATION
AND TAPER IN SHOP DRAWINGS AS REQUIRED TO MAINTAIN SLOPE PRIOR TO
INSTALLATION. REFER TO STRUCTURAL (IF APPLIES) FOR EXACT TOS/BOD ELEVATIONS.
REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.
PROVIDE TAPERED INSULATION CRICKETS (1/2"/FT. MIN. SLOPE) AT HIGH SIDE OF ALL
MECHANICAL UNITS, SMOKE VENTS, ROOF HATCHES, AND OTHER MISC. ROOF
PENETRATIONS, TO SHED WATER AROUND AND TO ENSURE POSITIVE ROOF DRAINAGE.
PROVIDE ADDITIONAL MANUFACTURER'S WALK PADS AS PROTECTION AT "SERVICE SIDE"
OF ALL MECHANICAL EQUIPMENT - FIELD VERIFY LOCATIONS. AS WELL AS PROTECTION AT
"ACCESS SIDE" OF ALL ROOF HATCHES AND ROOF ACCESS LADDERS - FIELD VERIFY
LOCATIONS, AND AT DOWNSPOUT LOCATIONS.
ALL WOOD BLOCKING AT ROOF EDGES ARE TO BE FABRICATED FROM CONT. 2X6 FR-WD
BOARDS. PROVIDE LARGER 2X FR-WD AS REQUIRED PER DIMENSIONED DETAILS OR AS
FIELD CONDITIONS DICTATE. ALL COPING TO BE SLOPED TOWARD THE INTERIOR.
ALL EXPOSED FLASHING, COPING (IF APPLICABLE), AND THEIR ACCESSORIES SHALL BE AS
SPECIFIED.
HEIGHT OF ALL NAILERS SHALL BE FLUSH WITH NEW INSULATION THICKNESS.
ALL THROUGH WALL FLASHING SYSTEMS TO ACCOMMODATE 8" MINIMUM FLASHING
HEIGHT FROM FINISHED ROOF SURFACE. PROVIDE END DAMS AS CONDITIONS ALLOW. ALL
FLASHING TO HAVE 4" LAP MINIMUM AND OR STEP.
ALL PITCH PANS SHALL BE DOUBLE SOLDERED STAINLESS STEEL AND RECEIVE EITHER
MECHANICALLY ATTACHED GOOSENECKS OR METAL BONNETS. METAL BONNETS SHALL
BE SECURED WITH CLAMPING RING AND SEALANT. SPECIAL CARE GIVEN TO WASH ALL
METAL PRIOR TO INSTALLATION.
ALL INFIELD EXPANSION JOINTS SHALL HAVE LOW SLOPED STANDING SEAM JOINTS AND
SHALL BE CHAMFERED AT TERMINATION AT ROOF EDGE TO MEET PROFILE OF PERIMETER.
ANY CRACKS OR VOIDS IN RISE WALLS ABOVE COUNTER FLASHING SHALL BE REPAIRED
WITH COMPATIBLE SEALANT.
ALL VERTICAL MEMBRANE FLASHING SHALL BE MECHANICALLY FASTENED AND INSTALLED
WITH NEW METAL COUNTER FLASHING UTILIZING A CONTINUOUS CLEAT. SLIDE METAL
COVER PLATE DOWN OVER VERTICAL CLEAT AND SEAL.
PROVIDE NEW CONCRETE SPLASH BLOCKS ON ROOF ELEVATION ON TOP OF A WALK PAD
WHERE DOWNSPOUTS OCCUR.
ALL PIPES AND CONDUIT SHALL RECEIVE PIPE SUPPORTS AND RELATED SHIMS AND SHALL
BE PLACED ON AN ADDITIONAL ADHERED ROOF MEMBRANE UNDER SPECIFIED WALK PAD
PRIOR TO SURFACE APPLICATION. SUPPORTS TO OCCUR AT 10'-0" O.C. AND WITHIN 2'-0" OF
ALL SLOPES, TEES AND CORNERS. ALL PIPES TO BE PAINTED PER BUILDING CODE
REQUIREMENTS.
ALL METAL FLASHING SHALL EXTEND BEYOND ROOF EDGE MIN. 8" WHERE FLASHING
ABUTS VERTICAL WALL SURFACE AS DETAILED. ALL FLASHING SHALL BE INSTALLED IN
SHINGLE FASHION.
AT ALL LOCATIONS WHERE CONVERGENCE OF MULTIPLE PLANES OF ROOFING TO WALL
OCCUR, FIELD FABRICATE THERMOPLASTIC BOOT TO BE INSTALLED OVER NEW ROOFING,
COMPLETELY OVERLAYING THE TRANSITIONS OF ALL ROOF TO WALL, ELEVATIONS, INSIDE
AND OUTSIDE 90 DEGREE CORNERS, ETC. PRIOR TO METAL INSTALLATION.
ALL EQUIPMENT CURBS TO BE RAISED AS NECESSARY TO MAINTAIN 10" MINIMUM HEIGHT
ABOVE FINISHED ROOF SURFACE.
MECHANICAL, ELECTRICAL, AND PLUMBING ROOF EQUIPMENT SHOWN ON THIS PLAN IS
FOR GENERAL INFORMATION ONLY.
FLASHING AND STRIPPING MATERIALS, BASE PLY SHEETS, MEMBRANES, INSULATION, AND
ACCESSORIES SHOULD BE AS RECOMMENDED BY THE ROOFING SYSTEM MANUFACTURER
FOR INTENDED USE AND COMPATIBILITY WITH THE MEMBRANE ROOFING SYSTEM.
WHERE WOOD BLOCKING EXCEEDS 6" IN VERTICAL THICKNESS AT TAPERED INSULATION,
PROVIDE STEM WALL CONSTRUCTED OF 6" GALVANIZED COLD FORMED METAL FRAMING
AT 16" O.C. WITH CONT. TRACK AT TOP AND BOTTOM AND WITH 3/4" FR-EXT GRADE
PLYWOOD AT EACH SIDE, TOP TO SLOPE WITH TAPERED INSULATION.
PROVIDE STEP FLASHING AND COVER PLATE AT SLOPED ROOF HIGH/LOW CONDITIONS.
GUTTERS SHALL BE PREFINISHED GALVANIZED STEEL, SIZE PER DRAWINGS, UNO.
PROVIDE PREFINISHED 1/4"x1 1/2" GALVANIZED STEEL BENT PLATE BRACKETS AND
PREFINISHED 1" GALVANIZED STEEL SPACERS AT 36" O.C. MAX, STAGGER WITH EACH
OTHER AT 18" O.C.
PROVIDE PREFINISHED GUTTER EXPANSION JOINTS 50'-0" O.C. MAX.
DOWNSPOUTS SHALL BE 5"x6" PREFINISHED GALVANIZED STEEL UNO WHERE LOCATED ON
ROOF PLAN. PROVIDE PREFINISHED 2" GALVANIZED STEEL HANGERS AT 36" O.C.
COORDINATE LOCATION WITH ARCHITECT PRIOR TO INSTALLATION.
PROVIDE SPLASH BLOCKS AT ALL ROOF LEADER NOZZLES THAT SPILL ONTO GROUND.
VERIFY ELEVATION OF ROOF DRAIN RELATIVE TO OVERFLOW SCUPPER PRIOR TO
INSTALLATION OF SCUPPERS.
LOCATE SCUPPERS AS INDICATED ON ELEVATIONS, EITHER CENTERED OVER
WINDOWS/OPENINGS, OR CENTERED BETWEEN WINDOWS/OPENINGS, UNO. ADJUST
PLACEMENT TO MEET MASONRY COURSING MODULES.
RTU MEME/G
P
EJ
OD
DS
OS
RD
RW RW/EJ
ODRD
SCSC
PITCH PAN
DS/SB
SPLASHBLOCK
DOWNSPOUT/
DS/CH
COLLECTOR HEAD
DOWNSPOUT/
P/EJ
RME
CW E
EDP
HS
VA
RPH
CD
CH
ETEL / FO
G
P/EJ
EXPANSION JOINT
AT PARAPET
METAL EDGE RISE WALL RISE WALL
W/EXPANSION
JOINT
RAISED METAL
EDGEPRIMARY AND
OVERFLOW ROOF
DRAIN
EXPANSION
JOINT
METAL EDGE
W/GUTTER
THROUGH
WALL
SCUPPER
OVERFLOW
SCUPPER PARAPET
SLOPE
DIRECTIONEXPANSION JOINT
AT PARAPET
ROOF LADDER
EDGE SCUPPER
CURB
MOUNTED
EQUIPMENT
MISC. EQUIP.
ON EQUIP.
CURBS
PRIMARY
ROOF
DRAIN
OVERFLOW
ROOF DRAIN
SOIL /
PLUMBING
VENT
FLANGE
MOUNTED
EQUIPMENT
HOT
STACK
CURB
MOUNTED
VENT
ANTENNA ELECTRICAL
DISTRIBUTION
PANEL
GUY
WIRE
ROOF
PENETRATION
HOUSING
SST SPLASH
PAN /
SUPPORT
PAD
ROOF TOP
UNIT
MISC.
EQUIPMENT
ROOF
HATCH
SKYLIGHT
PROCESS
VENT
STACK
FLANGE
MOUNTED
VENT
SATELLITE
DISH
CHILLER
LINE
GAS LINE
VENT
STACK
SECURITY
CAMERA
WATER
HYDRANT
ELECTRIC
DISCONNECT
PEDESTAL
CONDENSATE
LINE
ELECTRIC
LINE
TELE /
FIBER
OPTICS
ANCHOR
STANCHION
SL DOWNSPOUT
ROOF LEGEND
NOT IN CONTRACT
ROOF LEGEND
SHINGLE
ROOF SYSTEM
ROOF LEGEND
LOW SLOPE
ROOF SYSTEM
NRD
NEW
ROOF
DRAIN
WALK PAD AT
SERVICE SIDE
OF UNIT
ROOF TOP
UNIT
1/2" TAPERED
CRICKET ON HIGH
SIDE OF RTU
RTU
ROLLER AND SUPPORT LEG SIZE IS DEPENDENT ON PIPE OR
CONDUIT SIZE. MANUFACTURER TO PROVIDE PROPER SIZING
BASED ON FIELD CONDITIONS.
THREADED RODS,
NUTS, AND WASHERS
HIGH DENSITY
POLYPROPYLENE
PLASTIC W/ UV
INHIBITORS, TYP.
5/8" NEOPRENE PAD
RD OD
OS
RD
RECESSED PRIMARY AND
OVERFLOW DRAIN SUMP
1/2" TAPERED
CRICKET
RECESSED PRIMARY DRAIN
SUMP AND OVERFLOW SCUPPER
RD OD
RECESSED PRIMARY AND
OVERFLOW DRAIN SUMP
1/2" TAPERED
CRICKET
NOTES:
1. SUPPORT LEG SIZE IS
DEPENDENT ON PIPE OR
CONDUIT SIZE.
MANUFACTURER TO PROVIDE
PROPER SIZING BASED ON
FIELD CONDITIONS.
2. SET ON SACRIFICIAL SHEET.
16" NOMINAL
MASONRY BLOCKS
HOT DIP GALVANIZED STEEL MAST
SACRIFICIAL
MEMBRANEEXTEND MEMBRANE UP AND
OVER TOP OF PARAPET
WALL ATTACH ON FRONT
EDGE OF WALL SYSTEM
PREFINISHED METAL COPING
COLOR AS SELECTED BY OWNER
EXTEND METAL UP UNDER FLASHING
ABOVE AND SEAL WATERTIGHT
HIDDEN VERTICAL CLIP ATTACHED TO
BOTH SIDES OF WALL SYSTEM. SLIDE
PREFINISHED METAL DOWN OVER CLIP
AND PROVIDE BEAD OF SEALANT CONT,
VERTICAL BETWEEN EDGE AND
SURFACE ADJACENT PLANE.
EXTEND METAL FLASHING UP UNDER
COPING AS SHOWN
PREFINISHED METAL COPING COLOR
AS SELECTED BY OWNER
INTERIOR
CLOSURE
SCUPPER
LINER
EXTERIOR
CLOSURE
3" MIN.
FLANGE
SEAL EXTERIOR
CLOSURE TO
SCUPPER LINER WITH
APPROVED SEALANT
EXTERIOR CLOSURE
FLANGE WITH FORMED
EDGES ON 3 SIDES TO
RECEIVE APPROVED
SEALANT
3" MIN.
FLANGE
4" MIN.
FLANGE
SHEET METAL LINER
WELDED OR FABRICATED
FROM MEMBRANE
COATED METAL
5/8" NEOPRENE PAD
PIPE STAND SIZED
NOTES:
1. SUPPORT LEG SIZE IS DEPENDANT
ON PIPE OR CONDUIT SIZE.
MANUFACTURER TO PROVIDE
PROPER SIZING BASED ON FIELD
CONDITIONS.
2. SET ON SACRIFICIAL SHEET.
PIPE OR CONDUIT
ILLUSTRATION
ONLY
STRUT CLAMP
5/8" NEOPRENE PAD
" M
AX
4.
" M
IN
END
VIEW
WALK PADS
SAFETY
RAILING
ROOF HATCH
1/2" TAPERED
CRICKET ON HIGH
SIDE OF ROOF
HATCH
WALK PAD
ROOF LADDERS
WALK PADS
PARAPET
STAINLESS
STEEL FALL
PROTECTION
SCREEN
FALL
PROTECTION
SCREEN
OSHA APPROVED
LENS ARE
ACCEPTABLE
FIBERGLASS REINFORCED
POLYMER (FRP),
YELLOW, UV RESISTANT &
FIRE RETARDANT (∅1.91)
ALUMINUM POST HINGE
STAINLESS STEEL
TORSION ROD
SELF CLOSING (FRP)
GATE (∅1.91)ALUMINUM GATE HINGE
STEEL CORNER
BRACKETS (HOT
DIP GALVANIZED)
ALUMINUM
POST
SUPPORTS
42" ABOVE THE
ROOF SURFACE
OR DECK
SKYLIGHT WITH
FALL PROTECTION11
ROOF TO ROOF LADDER
WITH WALK PADS2ROOF TOP UNIT -
WALK PAD LAYOUT3ROOF HATCH
WALK PAD LAYOUT4ROOF HATCH
SAFETY RAILING5
ROLLER PIPE SUPPORT8LARGE PIPE -
PIPE STAND9 TAPERED CRICKETTAPERED SADDLES
ANTENNA SUPPORTCOPING END CAP
SCUPPER SHEET METAL10
14 13
7 6
NOT TO SCALE
ROOF PLAQUE1
NOT TO SCALENOT TO SCALENOT TO SCALENOT TO SCALE
NOT TO SCALE
NOT TO SCALE NOT TO SCALENOT TO SCALE
NOT TO SCALENOT TO SCALE
NOT TO SCALE
NOT TO SCALE
TYP SELF-ADH FLASHING
(AT WALL OPENINGS)12
NOT TO SCALE
DO NOT MAKE REPAIRS OR ALTERATIONS
TO THIS ROOF WITHOUT APPROVAL FROM THE
DIRECTOR OF OPERARIONS AND MAINTENANACE OFFICE
PROJECT NAME
PROJECT ADDRESS
THIS ROOF IS GUARANTEED FROM XX/XX/XX UNTIL XX/XX/XX
SCHOOL DISTRICT NAME,
DAY PHONE NUMBER
EMERGENCY PHONE NUMBER
ENVELOPE CONSULTANT NAME, PHONE NUMBER
ROOFING MANUFATURER NAME, PHONE NUMBER
GENERAL CONTRACTOR NME, PHONE NUMBER
ROOFING CONTRACTOR NAME, PHONE NUMBER
M U
LT
IP
LE
B
U
IL
D
IN
G S
C
AN
YO
N
, T X
A
B C
N.I.C.
2n 2n 2n 2n
2n2n2n2n
2e
2e 2e
2e
2r
2r
2r
2r
3e 3e 3e 3e
3e3e3e3e 3r 3r 3r 3r
3r 3r 3r 3r a a a a a a
3e 2n 3r 3r 2n 3e
2e 1 2r 2r 1 2e
3e 2n 3r 3r 2n 3e
JOB:
DATE:
DRAWN BY:
TEXAS REGISTERED
ENGINEERING FIRM F-6498
2505 79TH ST., SUITE A
LUBBOCK, TEXAS 79423
(972) 874-1388
IN
D U
ST
R
IE
S, IN
C
ARMKO
CONTRACTOR SHALL VERIFY ALL
SUBSTRATES, DIMENSIONS,
CURBS, PENETRATIONS, ECT.
THOSE SHOWN ARE TYPICAL BUT
MAY NOT BE ALL INCLUSIVE
Copyright 2025 by Armko Industries
ISSUES
CHECKED BY:
THIS DOCUMENT WAS
PRODUCED BY OR UNDER
THE DIRECT SUPERVISION
OF REGISTERED ENGINEER
REVISIONS
ISSUE DATE:
Issue For Construction 10/07/2025
WIND UPLIFT
PRESSURE PLAN -
GREENHOUSES
25-1183-49 10/07/2025
AA/JK
GS2.03
PR
O
JE
C
T
FO
R
W
ES
T
TE
XA
S
A& M
U N
IV
ER
SI
TY
R O
O F
R
EP
LA
C
EM
EN
T
PR
O
JE
C T
CB
01/20/2026
W
TA
M U
G R
EE
N
H O
U
SE
S
N
4T
H S
TR
EE
T, C
AN
YO
N , T
X
1/8" = 1'-0"
1 WIND UPLIFT PLAN - OVERALL - GREENHOUSES
1/32" = 1'-0"2 UPLIFT KEY PLAN - GABLE
2e
2e
2e
2e
2e
2e
2e
2e 2e
2e
2e
2e
2e
2e
2e
2e
2e
2e
2e
2e
2r 2r2r
2r
2r
2r
2r
2r
2r
2r
2r
2r
2r
2r
2r
2r
2r 2r
2r
2r
2r
2r
2r
2r
2r
2r 2r
2r
2r
2r2r
3e 3e
3e3e 3r 3r
3r 3r
3 3
3 3
3 3
A1 A2
A1 a a a a a a
3e 2n 3r 3r 2n 3e
2e 1 2r 2r 1 2e
3e 2n 3r 3r 2n 3e a a a a
2e3 3
2e3 3
2e2e
2r 2r
2r 2r
2r 2r
2r 2r
1 1
JOB:
DATE:
DRAWN BY:
TEXAS REGISTERED
ENGINEERING FIRM F-6498
2505 79TH ST., SUITE A
LUBBOCK, TEXAS 79423
(972) 874-1388
IN
D U
ST
R
IE
S, IN
C
ARMKO
CONTRACTOR SHALL VERIFY ALL
SUBSTRATES, DIMENSIONS,
CURBS, PENETRATIONS, ECT.
THOSE SHOWN ARE TYPICAL BUT
MAY NOT BE ALL INCLUSIVE
Copyright 2025 by Armko Industries
ISSUES
CHECKED BY:
THIS DOCUMENT WAS
PRODUCED BY OR UNDER
THE DIRECT SUPERVISION
OF REGISTERED ENGINEER
REVISIONS
ISSUE DATE:
Issue For Construction 10/07/2025
WIND UPLIFT
PRESSURE PLAN -
CONNER HALL
25-1183-49 10/07/2025
DB
GS2.04
PR
O
JE
C
T
FO
R
W
ES
T
TE
XA
S
A& M
U N
IV
ER
SI
TY
R O
O F
R
EP
LA
C
EM
EN
T
PR
O
JE
C T
CB
01/20/2026
C O
N N
ER
H
AL
L
R U
SS
EL
L
LO
N G
B
LV
D
C
AN
YO
N
, T X
3/32" = 1'-0"1 WIND UPLIFT PRESSURE PLAN - CONNER HALL
1/32" = 1'-0"
2 UPLIFT KEY PLAN - GABLE
1/32" = 1'-0"
3 UPLIFT KEY PLAN - HIP
A
RIDGERIDGE
R
ID
G E
R
ID
G E
R
ID
G E
VALL
EY
VALLEY
VALL
EY
VALL
EY
VALL
EY
VALLEY
VALLEY
VALLEY
HIPHIP
HIP
HIP
HIPHIP
HIPHIP
R W
R W
R W
R W
R W
R W
RW
RW
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE SL
O
PE
SLOPE
SLOPE
SLOPE
SLOPE
MEME
ME/G
M E
M E
ME
ME ME
ME
ME/G
ME ME
ME
ME/G
ME
ME/G
MEME
ME
ME
ME/G
ME
M E
M E
M E
M E
M E
M E
M E
M E
M E
M E
M E M
E
M E
M E
M E
M E
RWRW
RW RW
M E
M E
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
SL
O
PE
SLO
PE
SLOPE
VALLEY VALLEY
VA
LL
EY
VA
LL
EY
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
D S
M E/
G
D S
D S
D S
D S
ME
1 1
1 1
2 2
2 2
2 2
3 3
664 4
JOB:
DATE:
DRAWN BY:
TEXAS REGISTERED
ENGINEERING FIRM F-6498
2505 79TH ST., SUITE A
LUBBOCK, TEXAS 79423
(972) 874-1388
IN
D U
ST
R
IE
S, IN
C
ARMKO
CONTRACTOR SHALL VERIFY ALL
SUBSTRATES, DIMENSIONS,
CURBS, PENETRATIONS, ECT.
THOSE SHOWN ARE TYPICAL BUT
MAY NOT BE ALL INCLUSIVE
Copyright 2025 by Armko Industries
ISSUES
CHECKED BY:
THIS DOCUMENT WAS
PRODUCED BY OR UNDER
THE DIRECT SUPERVISION
OF REGISTERED ENGINEER
REVISIONS
ISSUE DATE:
Issue For Construction 10/07/2025
OVERALL ROOF
PLAN - CONNER HALL
25-1183-49 10/07/2025
AA/JK
R1.05
PR
O
JE
C
T
FO
R
W
ES
T
TE
XA
S
A& M
U N
IV
ER
SI
TY
R O
O F
R
EP
LA
C
EM
EN
T
PR
O
JE
C T
CB
01/20/2026
NOT TO SCALE1 OVERALL ROOF PLAN - CONNER HALL
TRUE
NORTH
SCOPE OF WORK PACKAGE II:
BASE PROPOSAL 6 – WTAMU CONNOR HALL – SHINGLES – ROOF SECTION A
WORK SHALL INCLUDE REMOVAL OF THE EXISTING SHINGLE ROOF
SYSTEM DOWN TO THE DECK.
PROVIDE NEW SYNTHETIC UNDERLAYMENT.
PROVIDE ALL ASSOCIATED SHEET METAL AND ACCESSORIES.
PROVIDE NEW ARCHITECTURAL COMPOSITION SHINGLES.
REMOVE AND REPLACE ALL FLASHINGS.
PROVIDE A TWO (2) YEAR CONTRACTOR ’S WARRANTY.
NEW METAL SHALL BE PREFINISHED, SELECTED BY THE OWNER FROM A
FULL RANGE OF COLORS.
WORK SHALL ALSO INCLUDE ALL HVAC AND ELECTRICAL, PIPING
DISCONNECT AND RECONNECTION.
INSTALLATION SHALL BE AS PER NRCA, SMACNA, ANSI/SPRI,
SPECIFICATIONS, DETAILS AND MANUFACTURER’S GUIDELINES.
ALL GAS LINES TO BE TESTED AND CERTIFIED BY A MASTER PLUMBER.
1.
2.
3.
4.
5.
6.
7.
SPECIFIC ROOF NOTES:
PROVIDE NEW 24 GAUGE PRE-FINISHED GUTTER AND DOWNSPOUTS AS
DETAILED.
PROVIDE VENTED HIP AND RIDGE VENTS AS DETAILED.
LEAD JACKS TO BE UTILIZED AT ALL PLUMBING STACKS.
INSTALL AN ADDITION LAYER OF THE UNDERLAYMENT AT ALL VALLEY AND
EAVE LOCATIONS.
PROVIDE SIX NAILS PER SHINGLE AS SPECIFIED.
INSTALL NEW VALLEY METAL AT THE VALLEY LOCATIONS.
ALL VENT FLASHINGS SHALL BE REPLACED AND PAINTED TO MATCH THE
NEW SHINGLE COLOR.
C O
N N
ER
H
AL
L
R U
SS
EL
L
LO
N G
B
LV
D
C
AN
YO
N
, T X
RW RW
R
ID
G E
ME
M E
M E
R
ID
G E
M E M
E
ME
ME
ME
M E
M E
SLOPE
SLOPE
SLOPE
SLOPE SLOPE
SLOPE
A
B C
N.I.C.
JOB:
DATE:
DRAWN BY:
TEXAS REGISTERED
ENGINEERING FIRM F-6498
2505 79TH ST., SUITE A
LUBBOCK, TEXAS 79423
(972) 874-1388
IN
D U
ST
R
IE
S, IN
C
ARMKO
CONTRACTOR SHALL VERIFY ALL
SUBSTRATES, DIMENSIONS,
CURBS, PENETRATIONS, ECT.
THOSE SHOWN ARE TYPICAL BUT
MAY NOT BE ALL INCLUSIVE
Copyright 2025 by Armko Industries
ISSUES
CHECKED BY:
THIS DOCUMENT WAS
PRODUCED BY OR UNDER
THE DIRECT SUPERVISION
OF REGISTERED ENGINEER
REVISIONS
ISSUE DATE:
Issue For Construction 10/07/2025
OVERALL ROOF
PLAN -
GREENHOUSES
25-1183-49 10/07/2025
AA/JK
R1.06
PR
O
JE
C
T
FO
R
W
ES
T
TE
XA
S
A& M
U N
IV
ER
SI
TY
R O
O F
R
EP
LA
C
EM
EN
T
PR
O
JE
C T
CB
01/20/2026
TRUE
NORTH
SCOPE OF WORK PACKAGE II:
BASE PROPOSAL 7 – WTAMU GREENHOUSES – POLYCARBONATE PANELS – ROOF
SECTIONS (A, B, & C)
WORK SHALL INCLUDE REMOVAL OF THE EXISTING POLYCARBONATE PANELS.
PROVIDE NEW POLYCARBONATE ROOF SYSTEM PER LIKE, KIND, AND QUALITY.
PROVIDE NEW ROOF ACCESSORIES TO MATCH EXISTING SIZE AND STYLE.
NEW METAL SHALL BE PREFINISHED, SELECTED BY THE OWNER FROM A FULL
RANGE OF COLORS.
PROVIDE A TWO (2) YEAR CONTRACTOR ’S WARRANTY.
WORK SHALL ALSO INCLUDE ALL HVAC AND ELECTRICAL, PIPING DISCONNECT
AND RECONNECTION.
INSTALLATION SHALL BE AS PER NRCA, SMACNA, ANSI/SPRI, SPECIFICATIONS,
DETAILS AND MANUFACTURER’S GUIDELINES.
ALL GAS LINES TO BE TESTED AND CERTIFIED BY A MASTER PLUMBER.
W
TA
M U
G R
EE
N
H O
U
SE
S
N
4T
H S
TR
EE
T, C
AN
YO
N , T
X
NOT TO SCALE1 OVERALL ROOF PLAN - GREENHOUSES
FLASHING
BASE SHEET
WOOD NAILERS
ROOF DECK
PLY SHEETS
PRIME WALL
PLY SHEET
COVERBOARD
THERMAL INSULATION
BASE SHEET IF REQUIRED
PLY SHEET FLASHING
EXTEND FIELD PLIES
ABOVE HEAD OF CANT3/4" EXTERIOR GRADE F.R.
PLYWOOD
WOOD NAILERS
CANT
ROOF DECK
THERMAL INSULATION
FIELD SHEET
FIELD SHEET
SHEET METAL
FASCIA CAP
FLASHING
PLY SHEET FLASHING
CANT STRIP
PREFINISHED SHEET
METAL GRAVEL STOP
PREFINISHED SHEET
METAL COVER PLATE
STANDING SEAM
FASTENER WITH WASHER
THROUGH ENLARGED HOLE
FLASHING
PLY SHEET
FIELD SHEET
EXISTING TO
REMAIN
FLOOD COAT
AND GRAVEL
NOT SHOWN
FOR CLARITY.
Z 1-1/2"
X
1-1/2"
Y
6" MIN.
BE
LO
W B
LO
C
KI
N
G 1-
1/ 2"
M
IN
12' MAXIMUM
LENGTH OF EACH PIECE
OF PARAPET CAP
SHOP FABRICATE
ROOF MEMBRANE - REF. TYP. DETAIL
BASE FLASHING
CUT EXCESS C/F FROM
PERIMETER OF SCUPPER
REFER TO PARAPET DETAIL FOR
FURTHER COPING AND FLASHING
INFORMATION
EXTEND FLASHING UP AND OVER
WOOD BLOCKING
REFER TO SPECIFICATIONS
FOR PARAPET WALL
APPLICATION PROCEDURES
STRIP IN PLY
1" M
IN
REFER TO PARAPET
DETAIL FOR TERM
BAR AT HIGH PARAPET
STANDING SEAM METAL CAP
PREFINISHED ALUMINUM TRIM
NOTES:
1. CONDUCTOR HEADS AND
DOWNSPOUTS SHOULD BE
FABRICATED OF THE SAME
MATERIAL. RECOMMENDED
MINIMUM FOR CONSTRUCTION
OF CONDUCTOR HEADS IS 24
GA. PREFINISHED GALVANIZED
STEEL
EXTEND BASE FLASHING INTO
SCUPPER AT MIN. OF 3" ON
BOTTOM AND SEAL ALL SIDES
WITH STRUCTURAL SEALANT
FIELD TO VERIFY
DIMENSIONS
SLOPE
CONTINUOUS FLEXIBLE
EMBED THROUGH-WALL
FLASHING
FASTENERS APPROX.
24" O.C.
RECEIVER
3" LAP WITH BEAD OF
SEALANT
COUNTERFLASHING
FASTENERS APPROX. 8"
O.C.
COVERBOARD
THERMAL INSULATION
ROOF DECK
8" M
IN
8"
CONT. METAL CLEAT
PRIME WALL
PROVIDE END DAM AT ALL
METAL (SOLDERED) &
MEMBRANE ICE & WATER
SHIELD (ADHERED)
FLASHING
ALUMINUM THRESHOLD
1/2" HIGH MAX. SET IN
BED OF SEALANT
RAINSCREEN
SILL GASKET
FIELD SHEET
FLASHING
BASE SHEET AS
REQUIRED
PLY SHEET
PLY SHEET FLASHING
FLASHING
FIELD SHEET
PLY SHEET
COVERBOARD INSUL.
THERMAL INSUL.
ROOF DECK
3/4" FIRE RATED EXT.
GRADE PLYWOOD
8"
PLY SHEET FLASHING
TERM BAR SET IN SEALANT
RECEIVER AND COUNTER
FLASHING
TPO MEMBRANE
EXISTING METAL
FLASHING
FIELD SHEET
PLY SHEET
COVERBOARD INSUL.
THERMAL INSUL.
ROOF DECK
3/4" FIRE RATED EXT.
GRADE PLYWOOD
8"
PLY SHEET FLASHING
TERM BAR SET IN SEALANT
RECEIVER AND COUNTER
FLASHING
TPO MEMBRANE
EXISTING SOIL STACK - EXTEND AS
NECESSARY
TO MAINTAIN 8" HEIGHT REQUIREMENT
NEW LEAD FLASHING - CRIMP INTO TOP
OF PIPE MIN. 1". PRIME FLANGE AND SET
IN MASTIC.
DIMENSIONAL SHINGLES AS SPEC. -
COLOR AS SELECTED BY ARCHITECT.
TWO PLIES OF FELTS AS SPEC.
NAILBASE INSULATION
EXISTING DECK TO
REMAIN
PLYWOOD
AIR GAP
SHINGLES TRIMMED 2" BACK FROM VALLEY
CENTERLINE
MINERALIZED ROLL ROOFING IN VALLEY
STORMGUARD LEAK BARRIER, MINIMUM 55 POUND
CENTER FULL WIDTH ROLL OF WEATHERWATCH OR
CARRY ROOF DECK PROTECTION ACROSS VALLEY
CLIPPED CORNER SET IN ROOF CEMENT
EXTEND SHINGLE AT LEAST 12" BEYOND
EXTRA FASTENER IN END OF SHINGLE
VALLEY CENTERLINE, NO FASTENERS WITHIN
VALLEY CENTERLINE
6" OF CENTERLINE
ROOF DECK PROTECTION
GUTTER NOT SHOWN FOR
CLARITY
2 PLIES OF FELTS AS SPEC
2"
6"
REFASTEN ALL EXISTING
DECKING WITH
NEW FASTENERS AS SPECIFIED
HEREIN
SELF-ADHERING
UNDERLAYMENT
AS SPEC.
NEW RAKE METAL EDGE
FLASHING
NEW PRE-FINISHED ALUMINUM
FASCIA TRIM AS DETAILED
SHINGLE STARTER
COURSE
NEW EAVE METAL
EDGE FLASHING
PLY SHEET FLASHING
" M
IN
FL
AS
H
IN
G H
EI
G
H T
FLASHING
FIELD SHEET
COVERBOARD
THERMAL INSULATION
ROOF DECK
EXTEND FIELD PLIES ABOVE
HEAD OF CANT STRIP
BEVEL TOP OF BOTH WOOD
CURBS TO DRAIN TO ONE SIDE
HIGH-DOMED, CAPPED, GASKETED
FASTENERS APPROX. 12" O.C.
WOOD CANT TO BRACE CURB
EACH SIDE
WOOD NAILERS
8"
3/4" LAP MIN.
PLY SHEET
10' MAXIMUM
LENGTH OF EACH PIECE
OF PARAPET CAP
1" M
IN
STANDING SEAM METAL CAP
WITH CONTINUOUS CLEAT ON
THE OUTSIDE CRIMP ENDS
OVER AT A 45 DEGREE ANGLE
FASTENERS
BASE SHEET AS REQUIRED
8"
M
IN
IM
U
M
'-0
8"
" M
IN
EJ WIDTH
REMOVABLE SHEET METAL
COUNTERFLASHING
3" LAP AT JOINT TYP.
PREFINISHED SHEET
METAL EXPANSION JOINT
COVER
MORTAR NET NOT SHOWN
FOR CLARITY
WOOD CANT TO BRACE CURB
FLEXIBLE VAPOR RETARDER
WITH COMPRESSIBLE INSUL.
EXTENDED FIELD PLIES ABOVE
HEAD OF CANT STRIP
SELF-ADHERED MEMBRANE SHEET
CLOSURE SECURED TO WALL WITH
TERM BAR & 3 COURSE MASTIC
ENSURING PROPER OVERLAP.
EXTEND UP AND UNDER RECEIVER
EXTEND BASE FLASHING UP AND
OVER WOOD BLOCKING
ROOF DECK
THERMAL INSUL.
COVERBOARD
BASE SHEET IF REQUIRED
BACKER ROD TO CREATE
BELLOWS AT MEMBRANE
3/4" EXTERIOR GRADE
F.R. PLYWOOD
FLASHING
PLY SHEET
FIELD SHEET
PLY SHEET FLASHING
CONT. CLEAT
TERMINATION BAR AND
SEALANT
PRIME WALL WHEN
APPLICABLE
TPO MEMBRANE
TERMINATION BAR AND
SEALANT
FLASHING
PLY SHEET FLASHING
RECEIVER AND COUNTER
FLASHING
SHEET METAL REGLET/RECEIVER
CONTINUOUS BEAD OF SEALANT
R2.01
R2.01
JOB:
DATE:
DRAWN BY:
TEXAS REGISTERED
ENGINEERING FIRM F-6498
2505 79TH ST., SUITE A
LUBBOCK, TEXAS 79423
(972) 874-1388
IN
D U
ST
R
IE
S, IN
C
ARMKO
CONTRACTOR SHALL VERIFY ALL
SUBSTRATES, DIMENSIONS,
CURBS, PENETRATIONS, ECT.
THOSE SHOWN ARE TYPICAL BUT
MAY NOT BE ALL INCLUSIVE
Copyright 2025 by Armko Industries
ISSUES
CHECKED BY:
THIS DOCUMENT WAS
PRODUCED BY OR UNDER
THE DIRECT SUPERVISION
OF REGISTERED ENGINEER
REVISIONS
ISSUE DATE:
Issue For Construction 10/07/2025
ROOF DETAILS
25-1183-49 10/07/2025
AA/JK
R2.04
PR
O
JE
C
T
FO
R
W
ES
T
TE
XA
S
A& M
U N
IV
ER
SI
TY
R O
O F
R
EP
LA
C
EM
EN
T
PR
O
JE
C T
CB
01/20/2026
NOT TO SCALE2 CHANGE OF ELEVATION
NOT TO SCALE5 TAPERED EXPANSION JOINT AND ROOF DIVIDER
NOT TO SCALE1 PRIMARY SPITTER
NOT TO SCALE3 DOOR SILL AT ROOF
NOT TO SCALE7 CHIMNEY COPING - 3 SIDED
NOT TO SCALE6 CHIMNEY COPING - 4 SIDED
NOT TO SCALE10 SHINGLES - VENT STACK
NOT TO SCALE11 SHINGLES - VALLEY
NOT TO SCALE9 SHINGLES - METAL EDGE
M U
LT
IP
LE
B
U
IL
D
IN
G S
C
AN
YO
N
, T X
NOT TO SCALE8 ROOF DIVIDER
NOT TO SCALE4 LARGE PARAPET EJ AT RISEWALL
1"
SECTION
EXISTING NAIL BASE TO
REMAIN. VERIFY &
CORRECT FASTENING
PATTER TO MEET CURRENT
FM UPLIFT REQUIREMENTS.
M
AT
C H
EX
IS
TI
N
G
CONT. EDGE CLIP. FASTENED
ACCORDING TO LOCAL WIND
UPLIFT CRITERIA.
EXISTING WOOD NAILERS
TO REMAIN
1"
NEW SELF ADHERING MEMBRANE
FLASHING AS SPEC.
DIMENSIONAL SHINGLES AS SPEC.
COLOR AS SELECTED BY
ARCHITECT
FASCIA NAILERS, REPAIR /
REPLACE DAMAGED OR ROTTEN
NAILERS
EXISTING PLYWOOD
*CONTRACTOR SHALL REPAIR/REPLACE
ROTTEN OR DAMAGED WOOD AS
NECESSARY.
TWO PLIES OF FELT AS SPEC.
INSTALL NEW DIMENSIONAL
SHINGLES AS SPEC. COLOR TO
BE SELECTED BY OWNER/
PROJECT MANAGER.
EXISTING WALL TO REMAIN
M
AT
C H
EX
IS
TI
N
G
FI
EL
D
VE
R
IF
Y
ADDITIONAL PLY OF SELF ADHERING
MEMBRANE FLASHING AS SPEC.
TWO PLIES OF FELT AS SPEC.
EXISTING PLYWOOD TO REMAIN
EXISTING INSULATION TO
REMAIN.
VENTED EAVE W/ PRE-FORMAL
FASCIA
AIR GAP
JOB:
DATE:
DRAWN BY:
TEXAS REGISTERED
ENGINEERING FIRM F-6498
2505 79TH ST., SUITE A
LUBBOCK, TEXAS 79423
(972) 874-1388
IN
D U
ST
R
IE
S, IN
C
ARMKO
CONTRACTOR SHALL VERIFY ALL
SUBSTRATES, DIMENSIONS,
CURBS, PENETRATIONS, ECT.
THOSE SHOWN ARE TYPICAL BUT
MAY NOT BE ALL INCLUSIVE
Copyright 2025 by Armko Industries
ISSUES
CHECKED BY:
THIS DOCUMENT WAS
PRODUCED BY OR UNDER
THE DIRECT SUPERVISION
OF REGISTERED ENGINEER
REVISIONS
ISSUE DATE:
Issue For Construction 10/07/2025
ROOF DETAILS
25-1183-49 10/07/2025
AA/JK
R2.05
PR
O
JE
C
T
FO
R
W
ES
T
TE
XA
S
A& M
U N
IV
ER
SI
TY
R O
O F
R
EP
LA
C
EM
EN
T
PR
O
JE
C T
CB
01/20/2026
M U
LT
IP
LE
B
U
IL
D
IN
G S
C
AN
YO
N
, T X
NOT TO SCALE1 SHINGLES - METAL EDGE GUTTER
File details come from the government source that posted it. Updated .