Plans_roadway and drainage-part 2.pdf
PDF 22 MB Posted
- Solicitation number
- 693C73-21-R-000018
About this file
This notice solicits proposals for the Arlington National Cemetery - Columbia Pike Realignment Project in Arlington County, Virginia. The project includes realigning Columbia Pike and S. Joyce Street, replacing Southgate Road with a new segment of S. Nash Street, expanding Foxcroft Heights Park, modifying the Columbia Pike/Washington Boulevard interchange, and constructing pedestrian and bicycle facilities to increase connectivity. The project will be split into a base schedule and option, with the total cost expected to exceed $10 million. Proposals are due on the date specified in Block 13a of the solicitation form SF 1442. Offerors must demonstrate experience with similar projects and submit qualifications by the deadline. The Department of Transportation Federal Highway Administration is issuing this request for proposals.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
E A S T E R N
F
D
A L
L
S
H
I G
W
Y
V I S
O e d e r a l i g h w a y d m n i s t r a t i o
U S p a r t t o f
T r a n s p o r t a t i
R
T
P
C I R C L
E R L
V I
LI
TO
TI
EM
ET
ER
SO
TH
X
PA
SI
(A
SE
EF
EN
ES
(D
) P
JE
TY
, V
IR
IN
IA
SHEET
Se al
TE
PR
IL
3, SC
LE
T.
IG
ED
EC
K
M
IS
UT
IT
TR
AN
SM
TA
04/23/2021
/A
EJ
2(2)
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
04/24/2021
PN
LL
2G(2)
TABLE I: RECOMMENDED SOIL SHEAR STRENGTH DESIGN PARAMETERS AND LATERAL EARTH PRESSURES
TABLE II: POST AND PANEL RETAINING WALL RECOMMENDATIONS
(Class A3 self-consolidating).
Sheets and Views
2G(2) RETAINING WALL NOTES AND DETAILS
TYPICAL SECTION - COLUMBIA PIKE
2.0%
2.0% 2.0%
ARL. CO. STD. C-2
CURB & GUTTER
PROFILE
GRADE
ARL. CO. STD.
C-3 CURB
COLUMBIA PIKE PLAN SHEET TYPICALS - 2A
INSET A
INSET C
INSET B
EXIST.
TIE TO EX. CURB
& GUTTER
STD. VDOT UD-2
MODIFIED VDOT UD-4
STA. 37+97.00 TO STA. 41+81.18
11.0'11.0'
VARIES 23.5' - 34.5'
VARIES 47' - 58'
VARIES 0'-11'
PROP.
ROW
THRU
LANE
GRASS
MEDIAN
11.0' 11.0'
23.5'
27.0'
11.0'11.0'1.5'
23.5'13.0'
47.0'
11.0' 11.0'
23.5'
1.5'
RIGHT-OF-WAY VARIES 88'-99'
RIGHT-OF-WAY 88.0'
STA. 41+81.18 TO STA. 57+59.06
5.0' 8.0'
BUFFER/
LNDSCP.
SIDEWALK
5.0'8.0'
10.0'
CYCLETRACKC/GC/G
C/G
13.0'
4.0'
5.0' 8.0'
CYCLETRACK
STA. 37+97.00 TO 38+57.51
STA. 40+10.98 TO STA.41+81.18
GORE
AREA
VARIES 0' - 8'
MID-BLOCK PEDESTRIAN CROSSWALK
STA. 48+19.30 TO STA.48+45.73
NOTES:
1. EXPANSION JOINTS IN C-3 HEADER CURB, C-2 STANDARD
CURB AND GUTTER SHALL BE 40' APART OR AT
EXPANSION JOINTS IN CONCRETE PAVEMENT.
2. EXPANSION JOINTS MAY BE OMITTED IF 1/8" JOINTS ARE
PLACED EVERY 10' OR LESS
3. EXPANSION JOINTS IN THE SIDEWALK SHALL BE 40'
APART. IF ADJACENT TO CONCRETE CURB. EXPANSION
JOINTS SHALL MATCH JOINT OF CURB. AN EXPANSION
JOINT SHALL BE PLACED BETWEEN CURB AND SIDEWALK.
4. ALL WIDENING SHALL BE IN ACCORDANCE WITH VDOT
STANDARD WP-2.
5. PROVIDE 6" MINIMUM 21B AGGREGATE BASE UNDER
CURB AND GUTTER.
6. PROVIDE 4" MINIMUM 21B AGGREGATE BASE UNDER
SIDEWALK, EXTENDED 4" BEYOND CONCRETE EDGES,
WHERE POSSIBLE.
7. CONTRACTOR SHALL PLACE A LAYER OF TACK COAT
BETWEEN EACH ASPHALT CONCRETE LIFT, AND BETWEEN
EXISTING PAVEMENT AND AN ASPHALT OVERLAY.
8. PROFILE GRADE POINT REPRESENTS THE PROPOSED
BASELINE ELEVATION SHOWN ON THE ROADWAY
PROFILES TAKEN AT THE PROPOSED PAVEMENT
SURFACE ALONG THE BASELINE, OR THE EXTENSION OF
ADJACENT PAVEMENT GRADE AT THE BASELINE.
9. SEE SHEET 2C(1) FOR MODIFIED UD-4 DETAIL
10. 21A OR 21B AGGREGATE BASE SHALL BE TYPE I IN
ACCORDANCE WITH SEC. 208 OF THE 2020 VDOT ROAD &
BRIDGE SPECIFICATIONS
12" SELECT FILL
(AS NEEDED - SEE
GEOTECH REPORT)
12" 21B AGGREGATE BASE
(EXT. UNDER C&G WHERE
APPLICABLE)
2" SM-9.5A BITUMINOUS
CONCRETE SURFACE
8" 21B AGGREGATE BASE
APPROVED SUBGRADE
4" CLASS A3
CONCRETE SIDEWALK
4" 21B AGGREGATE BASE
B.C.
8.0' +/-
EX. SIDEWALK
STA. 56+44.89 TO STA. 57+59.06
5.0' +/-
EX. BUF./
LNDSCP
EX.
E.O.P.
11.0'
TIE TO PROP.
S. NASH STREET
STA. 56+84.05 TO STA. 57+59.06
0.5'0.5'
0.5'
1.0' 1.0'
1.0'
STA. 38+42.54 TO STA. 41+58.83
STA. 38+42.54 TO STA. 41+58.83
STA. 41+81.18 TO STA. 56+44.89
STA. 41+81.18 TO STA. 56+76.45
B
2.0% MAX.
0.5' 0.5'
BENCH
TIE TO
S. JOYCE
STREET
STA. 37+97.00 TO STA. 38+36.14
2" SM-9.5D BITUMINOUS
2" IM-19.0D BITUMINOUS
8" BM-25.0D BITUMINOUS
(PLACED IN 2 EQUAL LIFTS)
FOR BUFFER/LANDSCAPE
STRIP DETAILS SEE
SHEET 2C(1)
INSET D
MODIFIED MOUNTABLE CURB & GUTTER
STA. 47+80.69 TO STA. 48+15.69
LIMIT OF EXCAVATION/
SUBGRADE FILL
' S
6"
2'-0"
1'-5"
1"
C-2M CURB & GUTTER
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
PI
2A
COLUMBIA PIKE PLAN SHEET TYPICALS - 2A(1)
2.0%2.0%
1. EXPANSION JOINTS IN HEADER CURB, STANDARD CURB
AND GUTTER SHALL BE 40' APART OR AT EXPANSION
JOINTS IN CONCRETE PAVEMENT.
STA. 30+76.34 TO STA. 37+97.00
12.0'12.0'
VARIES 25.5' - 36.5'
VARIES 51' - 62'
VARIES 0'-11'
LEFT TURN
12.0' 12.0'
25.5'
RIGHT-OF-WAY VARIES 96' - 105'
5.0'
15.0'
8.0'
2.0'
STA. 33+67.52 TO STA. 34+55.03
5.8' - 0'12.0'
12.0'
VARIES
LEFT
TURN
4.4' - 11'
STA. 30+76.34 TO STA.37+43.36
STA. 30+76.34 TO STA. 37+43.36
ARL. CO. STD. C-3
CURB (TYP.)
STA. 33+20.00 TO STA. 33+67.52
9.4' - 5.8'12.0'
LEFT
TURN
0' - 4.4'
STA. 31+89.62 TO STA. 33+20.00
VARIES 6' - 9.4'12.0'
STA. 30+76.34 TO STA. 31+89.62
VARIES 2' - 6'12.0'
TIE TO
S. JOYCE
STREET
STA. 37+43.36 TO 37+97.00
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
2A(1)
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
2A(10)
COLUMBIA PIKE PLAN SHEET TYPICALS - 2A(2)
STA. 28+76.60 TO STA. 29+53.50
10.0'VARIES 11' - 11.7'
VARIES 26' - 28'
VARIES 51' - 53'
6.0'
CONC.
10.0' VARIES 11' - 11.7'
VARIES 26' - 27'
RIGHT OF WAY VARIES 64' - 66'
C/G C/G
2.6'-2'1.2'-2'
VARIES 6'-15'
STA. 29+03.60 TO STA. 29+33.67
STA. 29+53.50 TO STA. 30+76.34
12.0'12.0'
VARIES 25.5' - 27.5'
VARIES 51' - 59'
THRU AND RIGHT
VARIES 15'-12' VARIES 15'-12'
VARIES 25.5' - 31.5'
RIGHT OF WAY VARIES 94' - 102'
15.0'
VARIES 0'-2'
STA. 30+13.82 TO STA. 30+26.62
VARIES 15'-14.3' VARIES 15'-14.3'
VAR.
VAR.
10.0'10.0'
STA. 28+77.81 TO STA. 29+33.67
STA. 28+76.73 TO STA. 29+33.67
STA. 30+14.38 TO STA. 30+76.34
STA. 30+13.82 TO STA. 30+76.34
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
2A(2)
SIDE STREET PLAN SHEET TYPICALS - 2A(3)
TYPICAL SECTION ROUTE 27 OFF-RAMP
VARIES 2.0%-4.0%
EX. RETAINING
WALL
VDOT STD.
CG-3
EX. ANC BOUNDARY WALL
INSET E
VARIE
VDOT STD. MB-7F
VARIES 16'-12'
THRU/RIGHT
VARIES 6'-10'
SHOULDER
EX. RT. 27
EDGE OF
TRAVEL LANE
STA. 2+10.94 TO STA. 4+66.39
VARIES 5'-28'
GORE AREA
1. EXPANSION JOINTS IN HEADER CURB, STANDARD CURB AND
GUTTER SHALL BE 40' APART OR AT EXPANSION JOINTS IN
CONCRETE PAVEMENT.
2. EXPANSION JOINTS MAY BE OMITTED IF 1/8" JOINTS ARE PLACED
EVERY 10' OR LESS
3. EXPANSION JOINTS IN THE SIDEWALK SHALL BE 40' APART. IF
ADJACENT TO CONCRETE CURB. EXPANSION JOINTS SHALL
MATCH JOINT OF CURB. AN EXPANSION JOINT SHALL BE PLACED
BETWEEN CURB AND SIDEWALK.
4. ALL WIDENING SHALL BE IN ACCORDANCE WITH VDOT STANDARD
WP-2.
5. PROVIDE 6" MINIMUM 21B AGGREGATE BASE UNDER CURB AND
GUTTER.
6. PROVIDE 4" MINIMUM 21B AGGREGATE BASE UNDER SIDEWALK,
EXTENDED 4" BEYOND CONCRETE EDGES, WHERE POSSIBLE.
7. CONTRACTOR SHALL PLACE A LAYER OF TACK COAT BETWEEN
EACH ASPHALT CONCRETE LIFT, AND BETWEEN EXISTING
PAVEMENT AND AN ASPHALT OVERLAY.
8. PROFILE GRADE POINT REPRESENTS THE PROPOSED BASELINE
ELEVATION SHOWN ON THE ROADWAY PROFILES TAKEN AT THE
PROPOSED PAVEMENT SURFACE ALONG THE BASELINE, OR THE
EXTENSION OF ADJACENT PAVEMENT GRADE AT THE BASELINE.
10. 21A OR 21B AGGREGATE BASE SHALL BE TYPE I IN ACCORDANCE
WITH SEC. 208 OF THE 2020 VDOT ROAD & BRIDGE
SPECIFICATIONS
VARIES 0'-12'
VARIES 4'-12'VARIES
VARIES 26'-38'
VARIES 10' - 11'
VARIES 22'-26'
STA. 4+66.39 TO STA. 6+13.27
SHLDR.
VARIES 0'-21'
STA. 4+11.15 TO STA. 4+23.91
VARIES 9' - 10'
STA. 4+23.91 TO STA. 4+62.79
VARIES 9' - 11'
GRADED
1.4'
TIE TO EXIST.
VARIES 2.0%-4.0%
VARIES 13'-12' VARIES 8'-10'
VARIES 14.5'-28
GORE AREA
8.0' VARIES
6.5'-20'
STA. 3+16.18 TO STA. 4+66.39
2" MILL AND OVERLAY WITH
SM-9.5D BITUMINOUS CONCRETE
SURFACE
EXIST. PAVEMENT SECTION
EXIST. SUBGRADE
INSET F
MATCH EX.
13.5' - 6'
12" CEMENT TREATED
AGGREGATE BASE
MATERIAL
TACK COAT
STD. VDOT UD-4
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
04/27/2021
2A(3)
Sheets and Views
2A(3) TYPICAL SECTIONS
VDOT STD. CG-3
SIDE STREET PLAN SHEET TYPICALS - 2A(4)
VDOT STD. MB-7D
2.0
2.0
16.0'
VARIES 42'-52'
12.0' VARIES 10'-8'
VARIES 26'-36'
STA. 6+13.27 TO STA. 7+62.79
VARIES 0'-12'
RIGHT TURN
VARIES - 14' MIN.
THRU/RIGHT LANE
EOP
VARIES 2.5'-6.2'
VARIES 6.2'-12'
STA. 6+45.00 TO STA. 6+90.14
STA. 6+90.14 TO STA. 7+20.21
GRADED AREA
(FUTURE CEMETERY
WALL TRAIL)
VARIES 4'-16'
VARIES 8' - 10'
VARIES 6.2'-12'
REQUIRED
STA. 7+20.21 TO STA. 7+62.79
2'
VARIES 4'-10'
VARIES 4'-10'
VARIES 4'-8'
STA. 6+22.07 TO STA. 6+83.46
PAVED
EX. SHOULDER
MILL/OVERLAY
GUARDRAIL
TIE TO EXIST. EDGE
OF TRAVEL LANE
MATCH
STA. 6+83.46 TO STA. 7+62.79
EX. GRADEDEX. SHOULDER
4.0' 4.0'
TYPICAL SECTION ROUTE 27 WESTBOUND LANES
VARIES 11'-12'
THRU LANE
STA. 1024+65.43 TO STA. 1030+60.99
VARIES 11'-12'
PAVEMENT
EXIST,
THRU LANE
VARIES 8'-11'
VDOT STD. MGS
GUARDRAIL (SEE
ROADWAY PLANS
3, 11, AND 12)
10'
STA. 1026+85.56 TO STA. 1027+57.56
EXIST. CONC.
BRIDGE DECK
VARIES 10'-11'
10:1 MAX.
VDOT
STD. CG-3
8.5'
EXIST. BRIDGE
PARAPET
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
2A(4)
SIDE STREET PLAN SHEET TYPICALS - 2A(5)
RETAINING WALL
DAR-B
48.0'
12.0' 8.0'
36.0'
STA. 7+62.79 TO STA. 12+03.09
ALL MVMT. LANE
STA. 7+83.46 TO STA. 11+44.82
VARIES 14.0'-27.0'
STA. 11+26.82 TO STA. 11+50.31
VARIES 7.0'-14.5'
STA. 11+44.82 TO STA. 11+48.14
STA. 11+48.14 TO STA. 11+71.53
STA. 11+26.82 TO STA. 11+50.31
STA. 7+62.79 TO STA. 11+50.31
STA. 7+62.79 TO STA. 7+83.46
EX. GRADEDEX. SHLDR
4.0' 4.0'
MAX.
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
2A(5)
TYPICAL SECTION ROUTE 27 ON-RAMP
SIDE STREET PLAN SHEET TYPICALS - 2A(6)
STA. 0+00.00 TO STA. 7+50.00
12.0'VARIES
29.5'
16.0'
SHLDR. TRAVEL LANE
17.5'
28.0'
STA. 4+15.63 TO STA. 6+44.51
VARIES 8'-0.6'
STA. 5+01.72 TO STA. 6+86.28
VAR. 4'-2'
STA. 6+44.51 TO STA. 7+03.98
0.8'
STA. 0+67.66 TO STA. 6+86.28
CURB AND GUTTER
STA. 0+39.66 TO STA. 0+84.17
VARIES 42.5'-0'
VAR. 4'-2'
VARIES 11.5'-5.5'
EX. SHOULDER
MILL/ OVERLAY
STA. 7+03.98 TO STA. 7+29.95
VAR. 5.5'-0' 16.0'
EX. TRAVEL LANE
SHLDR
TYPICAL SECTION ROUTE 27 ON-RAMP
STA. 7+29.95 TO STA. 7+50.00
DAR-C
DAR-C
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
2A(6)
TYPICAL SECTION S. JOYCE STREET
SIDE STREET PLAN SHEET TYPICALS - 2A(7)
CONCRETE
15.0' 11.0'
12.0' 12.0'
STA. 111+75.00 TO STA. 114+56.51
33.5'
66.0'
32.5'
100' RIGHT OF WAY
4.0'9.0'
5.0' 10.0'
1.0'1.0'2.0' 2.0'
6. PROVIDE 4" MINIMUM 21B AGGREGATE BASE HAVING
CBR-30 UNDER SIDEWALK, EXTENDED 4" BEYOND
CONCRETE EDGES, WHERE POSSIBLE.
C/GC/G
STA. 112+30.79 TO STA. 112+63.23
STA. 112+41.15 TO STA.112+63.23
TYPICAL SECTION S. JOYCE STREET
C-3 CURB (TYP.)
CONCRETE
VARIES 13.41'-14'
VARIES 10'-12' VARIES 10'-12'
STA. 111+50.00 TO STA. 111+75.00
VARIES 29.7'-31.5'
VARIES 58.4'-62'
VARIES 28.7'-30.5'
100' RIGHT OF WAY
VARIES 0'-4'
VARIES 9'-13.5'
VARIES 0'-5.5'
VARIES 10'-15.5'
1.0'1.0'
VARIES 2'-3.2' VARIES 2'-4.7'
C/GC/G
2.0%2.0%
VARIES 11.61'-14.19'
CONCRETE MEDIAN
VARIES 0'-6.85'
EXISTING PIER
PROTECTION
STA. 111+50.00 TO STA. 112+06.45
STA. 112+63.23 TO STA. 113+20.13
STA. 112+63.23 TO STA. 113+99.92
INSET AINSET A
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
2A(7)
SIDE STREET PLAN SHEET TYPICALS - 2A(8)
TYPICAL SECTION SOUTHGATE ROAD
CURB & GUTTER (TYP.)
13.5'13.0'
13.5'
RIGHT OF WAY VARIES 62.5'-87'
S. NASH STREET TO WEST PROJECT LIMIT
STA. 10+00.00 TO STA. 13+61.93
2.0' 6.0'
12.5'
VARIES 6'-8'
PARKING
STA. 12+03.70 TO STA. 12+27.45
VARIES 0'-10.5'
VARIES 12.5'-0'
20.5'
STA. 12+27.45 TO STA. 12+88.61
10.5'
STA. 12+88.61 TO STA. 13+61.93
10.5'
STA. 11+89.36 TO STA. 13+17.41
STA. 10+54.53 TO STA. 12+03.70
STA. 10+33.76 TO STA. 10+86.25
STA. 11+34.26 TO STA. 11+89.36
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
2A(8)
TYPICAL SECTION
S. NASH STREET
COLUMBIA PIKE PLAN SHEET TYPICALS - 2A(9)
TYPICAL SECTION S. OAK STREET
VDOT STD. RW-3
DAR-D WITH HR-1
TYPE II HANDRAIL
12.5'25.0'
25.0'
12.5'
56' RIGHT OF WAY
STA. 100+48.08 TO STA. 108+73.91
8.0' 5.0'
STA. 100+48.08 TO STA. 107+18.00
5.0'10.0'
LNDSCP. BUFFER/
STA. 106+62.54 TO STA. 107+54.12
STA. 108+34.49 TO STA. 108+55.95
5.0'6.0'
STA. 106+95.01 TO STA. 107+17.92
5" BM-25.0D BITUMINOUS
6" 21B AGGREGATE BASE
STA. 100+51.78 TO STA. 107+58.35
TYPICAL SECTION S. ODE STREET
18.0'
PAVEMENT
MILL / OVERLAY
STA. 107+19.15 TO STA. 107+76.49
GRADING
C/G GRADED
37.0'
19.0'
TYPICAL SECTION DRIVEWAY
SOUTHGATE ROAD STA. 11+75.00
VARIES 8.8' TO 23.8'
17.5'
8.8'
% VARIES
% VARIES
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
2A(9)
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
2B
FOR USE ON STAIRS NEAR S. OAK ST. AND SOUTHGATE ROAD
1. FOR ALL VDOT STANDARD ITEMS CONTRACTOR SHALL REFERENCE
VDOT 2020 ROAD AND BRIDGE SPECIFICATIONS UNLESS OTHERWISE
SPECIFIED.
2. THICKNESS OF AGGREGATE BASE LAYERS SHOWN IN THE ARLINGTON
COUNTY STANDARD DETAILS HEREIN ARE MINIMUMS. ALL PAVEMENT
SECTION DETAILS SHOWN IN THE TYPICAL SECTION PLANS SUPERCEDE
AGGREGATE BASE DIMENSIONS SHOWN ON THIS SHEET. SEE SHEETS
2A - 2A(10) FOR DETAILS.
4'
TRANSITION TO CG-3
RADIUS (FT.)
AS NOTED ON
PLANS
2" HIGH
MOUNTABLE
CURB
DETAIL A - PLAN VIEW
NOT TO SCALE
DETAIL B - PROFILE VIEW
NOT TO SCALE
NOSE DOWN CURB DETAIL
FOR USE AT RT. 27 OFF-RAMP GORE AREA
Sheets and Views
2B DETAILS
PAINTED NOSE
(THEORETICAL GORE POINT)
MARKED GORE AREA
(NEUTRAL AREA)
.B
RAMP PROPER
.6
ROUTE 27 OFF-RAMP
FLOW LINE
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
2B(1)
FF
-R
1" =2
0'
Sheets and Views
2B(1) ROUTE 27 OFF-RAMP GORE DETAIL
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
1. RETAINING WALL DAR-D TO BE VDOT STANDARD RW-3 CONCRETE GRAVITY RETAINING WALL (SEE VDOT
STANDARD DRAWING 401.02 THIS SHEET).
2. ALL PROPOSED RETAINING WALLS SHALL INCLUDE CUSTOM ROCK® FORMLINER, "RANDOM CUT STONE"
PATTERN #1106-R2 (SEE SPECIFICATION - THIS SHEET), OR APPROVED EQUAL. SHOULD THE
CONTRACTOR ELECT TO USE AN ALTERNATIVE RETAINING WALL FORMLINER, SHOP DRAWINGS AND
SPECIFICATIONS FOR THE ALTERNATE FORMLINER SHALL BE SUBMITTED TO CONTRACTING OFFICER
FOR REVIEW AND APPROVAL.
3. FORMLINER TO BE APPLIED TO ALL PROPOSED RETAINING WALLS (SEE NOTES 2 AND 3) SHALL HAVE 2"
RELIEF AND 12" VERTICAL COURSING. CONTRACTING OFFICER TO PROVIDE FINAL APPROVAL OF
FORMLINER TO BE APPLIED.
4. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING ITEMS TO BE IMPACTED BY CONSTRUCTION OF ALL
RETAINING WALLS. BEFORE RETAINING WALL CONSTRUCTION, CONTRACTOR SHALL NOTIFY
CONTRACTING OFFICER OF ANY ITEMS TO BE IMPACTED BY WALL CONSTRUCTION THAT ARE NOT
EXPLICITLY CALLED OUT FOR REMOVAL OR RELOCATION IN THE PLANS.
5. AFTER EXCAVATION TO THE DESIGN SUBGRADE LEVEL AND PRIOR TO PLACEMENT OF NEW FILL, THE
FINAL SUBGRADE SHALL BE PROOF-ROLLED WITH A MINIMUM OF FOUR PASSES. THE PROOF-ROLL
VEHICLE SHALL BE A FULLY LOADED (25 TONS) TANDEM-AXLE DUMP TRUCK. UNSUITABLE MATERIAL
AND AREAS THAT SHOW SIGNS OF MOVEMENT, RUTTING, OR INSTABILITY SHALL BE UNDERCUT TO
COMPETENT MATERIALS AS PER TABLE I (RW-3 RETAINING WALL RECOMMENDATIONS). THE UNDERCUT
SHALL EXTEND OUTSIDE THE BOTTOM OF FOOTING AT LEAST AN EQUAL DISTANCE TO THE UNDERCUT
DEPTH. THE PROOF-ROLL VEHICLE SHALL PASS UNTIL THERE IS NO VISIBLE EVIDENCE OF FURTHER
DENSIFICATION WITH A MINIMUM OF FOUR PASSES OVER THE PROPOSED WALL FOUNDATION ZONE. NO
DENSITY TEST WILL BE REQUIRED.
6. FOR BACK DRAIN DETAILS, REFER TO VDOT ROAD AND BRIDGE STANDARDS RW-3. THE GRAVEL BACK
DRAIN SHALL BE COMPLETELY WRAPPED WITHIN A FILTRATION GEOTEXTILE FABRIC NETTING PER THE
REQUIREMENTS OF SECTION 245.03(C) OF THE VDOT ROAD AND BRIDGE STANDARDS.
7. UNSUITABLE OR UNSTABLE FOUNDATION MATERIAL BELOW THE BOTTOM OF THE WALL EXPOSED
DURING CONSTRUCTION SHALL BE REMOVED AND REPLACED AS FOLLOWS:
BACKFILL WITH SELECT MATERIAL TYPE I MINIMUM CBR 30 TO THE DEPTH(S) AND EXTENTS INDICATED
IN TABLE I RW-3 RETAINING WALL RECOMMENDATIONS OR AS DIRECTED ON SITE BY THE
GEOTECHNICAL FIELD ENGINEER OR THEIR TECHNICAL REPRESENTATIVES IF ENCOUNTERED AT THE
TIME OF CONSTRUCTION. FOR BACKFILL CONTAINING OPEN-GRADED AGGREGATES IN VDOT ROAD AND
BRIDGE SPECIFICATIONS, DENSITY TEST IS NOT REQUIRED BUT EACH LIFT SHALL BE COMPACTED
UNTIL THERE IS NO VISIBLE EVIDENCE OF FURTHER DENSIFICATION. A MINIMUM OF FOUR PASSES
WITH HEAVY ROLLER (25 TONS MINIMUM) SHALL BE USED. COMPACTION EFFORTS SHALL BE OBSERVED
AND APPROVED BY A CERTIFIED QUALIFIED INSPECTOR OR GEOTECHNICAL ENGINEER.
8. FOR ALL DETAILS INCLUDED HEREIN, "ENGINEER" OR "PROJECT OFFICER" REFERS TO AND SHALL MEAN
"CONTRACTING OFFICER" AS APPLICABLE.
9. VDOT STANDARD RW-3 CONCRETE RETAINING WALLS TO HAVE CLASS A-3 CONCRETE. RW-3 WALLS TO
RECEIVE HR-1 HANDRAIL SHALL HAVE AT LEAST 2,500 PSI COMPRESSIVE STRENGTH NECESSARY FOR
HANDRAIL ANCHORAGE.
2G
TABLE I: RW-3 RETAINING WALL RECOMMENDATIONS
Sheets and Views
2G RETAINING WALL NOTES AND DETAILS
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
REMENTS OF THIS SUBDIVISION 19.
2(1)
S T E
A L
L
I S d e r a i s t r a t i
S a r t o f
T r a n s p o r t a t i
R
I R C
E R L
V I
1. THESE PLANS ARE INCOMPLETE UNLESS ACCOMPANIED BY THE SUPPLEMENTAL SPECIFICATIONS AND SPECIAL PROVISIONS INCLUDED IN
THE CONTRACT DOCUMENTS, INCLUDING THE VDOT PROJECT SPECIFIC SPECIAL PROVISION FOR SOLDIER PILE RETAINING WALL. WALL
CONSTRUCTION SHALL BE IN ACCORDANCE WITH VDOT PROJECT SPECIFIC SPECIAL PROVISION FOR SOLDIER PILE RETAINING WALL.
2. CONTRACTOR SHALL FIELD VERIFY LOCATION AND DIMENSION OF EXISTING AND/OR PROPOSED UTILITIES AND DRAINAGE STRUCTURES
WITHIN DISTANCE OF 2H FROM SOLDIER PILES. CONTRACTOR SHALL MAKE ALL NECESSARY ADJUSTMENTS TO RETAINING WALL TO
ACCOMMODATE EXISTING AND/OR PROPOSED UTILITIES. CONTRACTOR SHALL COMMUNICATE WITH ALL UTILITY OWNERS THAT HAVE
EXISTING FACILITIES IN CLOSE PROXIMITY TO THE RETAINING WALL AND DETERMINE WHAT PROTECTIVE MEASURES WILL BE REQUIRED
DURING THE CONSTRUCTION OF THE RESPECTIVE RETAINING WALL. WALL PANEL LENGTHS MAY BE SHORTENED SO THAT FOUNDATIONS
MAY BE ADJUSTED TO AVOID CONFLICTS AND CLEAR EXISTING PIPES, UTILITIES, AND UNDERGROUND OBSTRUCTIONS. THE ENGINEER
SHALL APPROVE FIELD ADJUSTMENTS TO SHAFT SPACING PRIOR TO CONSTRUCTION.
3. WALLS SHALL BE DESIGNED FOR A 75 YEAR SERVICE LIFE.
4. RETAINING WALLS NOT EXPLICITLY IDENTIFIED AS VDOT STANDARD RW-3 GRAVITY WALLS ARE TO BE DESIGNED BY A QUALIFIED
CONTRACTOR OR SUBCONTRACTOR IN ACCORDANCE WITH THE APPROVED PLANS, DETAILS, AND SPECIFICATIONS.
5. COMPLETE WORKING DRAWINGS / SHOP PLANS AND DESIGN CALCULATIONS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW AND
APPROVAL PRIOR TO BEGINNING WALL WORK, INCLUDING BUT NOT LIMITED TO: DRILLED SHAFTS, INSTALLATION OF RETAINING WALL
STEEL POST, FABRICATION OF PRECAST CONCRETE PANELS AND COMPLETE DETAILS OF CONNECTIONS (IF REQUIRED). THE CONTRACTOR
SHALL SUBMIT A FASCIA PANEL ERECTION PLAN AND CAST IN PLACE CONCRETE POUR SEQUENCE FOR APPROVAL BY THE ENGINEER.
6. FOR ROADWAY GEOMETRY, SEE ROADWAY PLANS.
7. THE RETAINING WALL HORIZONTAL CONTROL LINE WORK POINTS ARE LOCATED AT THE FRONT FACE OF THE STEEL PILE OUTER FLANGES, UNLESS OTHERWISE DIRECTED BY A QUALIFIED STRUCTURAL ENGINEER. RETAINING WALL STATIONS AND OFFSETS SHOWN IN
DRAWINGS ARE CALCULATED BY PROJECTING THE OFFSETS FROM THE CONTROLLING BASELINE TO THE WORK POINTS. RETAINING WALL
DIMENSIONS ARE MEASURED BETWEEN WORK POINTS. SECONDARY GUTTER LINE AND BENCH LINE ELEVATIONS ARE CALCULATED BY
PROJECTING THE OFFSET FROM THE CONTROLLING BASELINE TO THE RETAINING WALL WORK POINTS.
8. DESIGN OF DRILLED SHAFT FOUNDATIONS FOR POST AND PANEL WALLS SHALL BE MADE IN SUCH A WAY THAT THEY DO NOT INTERFERE
WITH THE FOUNDATIONS FOR ANY PROPOSED LIGHT OR SIGN STRUCTURE. THE FOUNDATION LOCATIONS FOR LIGHTING AND SIGN
STRUCTURES SHALL BE DETERMINED FROM THE APPROPRIATE PLANS.
9. POST SHALL MEET THE REQUIREMENT OF SECTION 403 VDOT RBS AND ASTM A572 GRADE 50. THE POSTS SHALL BE PLACED IN
PRE-AUGERED HOLES AND BACKFILLED WITH CLASS A3 CONCRETE (SECTION 217 VDOT RBS) MODIFIED TO MEET REQUIREMENTS OF SELF
CONSOLIDATING CONCRETE (SCC) BELOW THE TOP OF THE SHAFT ELEVATION (TOS), AND LEAN CONCRETE OF FLOWABLE FILL (150 PSI
AT 28 DAYS) ABOVE TOS.
10. CLEAR DISTANCE FROM THE EDGE OF SHAFT TO CORNER OF H-PILE IN ACCORDANCE WITH "VDOT PROJECT SPECIFIC SPECIAL PROVISION
FOR SOLDIER PILE RETAINING WALL."
11. STRUCTURAL STEEL PILES SHALL BE GALVANIZED PER SPECIFICATIONS SECTION 223. THE STEEL PILES ARE REQUIRED TO BE GALVANIZED
AT A MINIMUM FOR THE EXPOSED LENGTH PLUS THE TOP THREE FEET EMBEDDED INTO THE CONCRETE SHAFT.
12. WOOD LAGGING SHALL CONFORM TO FHWA-IF-99-015.
13. THE DESIGN SHALL BE IN ACCORDANCE WITH THE SOIL TYPES AND SOIL DESIGN PARAMETERS IN 'TABLE I - RECOMMENDED SOIL SHEAR
STRENGTH DESIGN PARAMETERS AND LATERAL EARTH PRESSURES' AS SHOWN IN SHEET 2G(2) AND ACCORDING TO THE GEOTECHNICAL
RECOMMENDATIONS INCLUDED IN THE GEOTECHNICAL REPORT FOR THE PROJECT.
14. THE GENERAL SOLDIER PILE RETAINING WALL RECOMMENDATIONS FOR GLOBAL STABILITY CONSIDERATIONS ARE PRESENTED IN THE
"FINAL GEOTECHNICAL ENGINEERING REPORT", DATED MARCH 10, 2021.
15. SOLDIER PILE RETAINING WALLS SHALL BE DESIGNED TO LIMIT WALL DEFLECTIONS IN ACCORDANCE WITH THE VDOT SOLDER PILE
RETAINING WALLS SPECIAL PROVISION TO 0.01H IN CANTILEVER CONDITIONS, WHERE H IS THE EXPOSED FACE HEIGHT OF THE WALL.
16. CONTRACTOR IS REQUIRED TO SUBMIT A MONITORING PLAN FOR REVIEW AND APPROVAL BY THE CONTRACTING OFFICER OR APPOINTED
REPRESENTATIVE PRIOR TO BEGINNING ANY RETAINING WALL INSTALLATION. MONITORING PLAN SHALL ADHERE TO CURRENT VDOT
STANDARDS AND REQUIREMENTS. WHERE AN APPLICABLE VDOT STANDARD IS NOT AVAILABLE, MONITORING REQUIREMENTS SHALL
DEFAULT TO CURRENT FHWA STANDARDS.
17. A RESISTANCE FACTOR OF 0.75 SHALL BE APPLIED TO THE PASSIVE EARTH PRESSURE FOR THE UPPER STRENGTH LIMIT STATE. PASSIVE
EARTH PRESSURE SHALL BE IGNORED WITHIN THE TOP TWO FEET OF THE GROUND SURFACE IN FRONT OF THE WALL. WHERE DRAINAGE
IS PROPOSED IN FRONT OF THE WALL, THE PASSIVE EARTH PRESSURE SHALL BE IGNORED TO TWO FEET BELOW THE INVERT OF THE
DRAINAGE.
18. POSITIVE DRAINAGE SHALL BE PROVIDED ABOVE WALLS. WHERE THE RETAINING SOIL SLOPED TOWARD THE WALL, CONSTRUCTION OF A
LINED BROW DITCH TO CAPTURE AND DIVERT SLOPE RUNOFF AWAY FROM THE FACE OF THE WALL SHALL BE REQUIRED.
19. SOLDIER PILE WALLS SHALL INCLUDE A DRAINAGE MAT BETWEEN THE LAGGING AND FASCIA. A FILTER FABRIC BETWEEN THE WOOD
LAGGING AND OPEN GRADED POROUS BACKFILL SHALL BE INSTALLED AS A SEPARATION LAYER TO ENSURE LONGEVITY OF THE WOOD
DRAINAGE AFTER THE WOOD LAGGING ROTS AWAY.
20. WEEP HOLES SHALL BE PROVIDED AT EACH BOTTOM PANEL.
21. THE PROVISIONS OF ARTICLE 10.7.5 OF AASHTO SHALL APPLY TO DETERMINE THE SOIL AGGRESSIVENESS.
22. NEOPRENE BEARING PADS OR EQUIVALENT WILL BE ADDED AS NEEDED BETWEEN BOTTOM PRECAST PANEL AND TOP OF SHAFT TO
PREVENT PANEL DAMAGE.
23. HEAVY CONSTRUCTION EQUIPMENT SHOULD BE KEPT A MINIMUM HORIZONTAL DISTANCE OF 5 FT AWAY FROM THE BACK OF THE WALL.
24. THE WALL DESIGNER SHALL TAKE INTO CONSIDERATION THE DISTRIBUTED SHEAR FORCE AND DEPTH OF APPLICATION AS PRESENTED IN
TABLE II POST & PANEL WALL RECOMMENDATIONS IN SHEET 2G(2). THE SPACING AND DEFLECTION PROVIDED IN THE TABLE SHALL BE
TAKEN INTO CONSIDERATION FOR THE FINAL DESIGN OF THE SOLDIER PILE WALL.
25. THE WALL DESIGNER MAY CHOOSE TO CHANGE THESE PILES TYPES AS LONG AS THE PROPOSED PILES’ SECTION MODULUS AND MOMENT
OF INERTIA ARE EQUAL TO OR GREATER THAN THE PILE SIZES PROVIDED IN TABLE II, POST & PANEL RETAINING WALL
RECOMMENDATIONS IN SHEET 2G(2).
2G(1)
EX. GUARDRAIL
1'
4'
VARIES 42.37' TO 84.04'
WEEPHOLE
DRILLED SHAFT
CONCRETE SHAFT
BOTTOM OF WALL / TOP
OF DRILLED SHAFT
PRECAST CONCRETE
PANEL
POROUS BACKFILL
EXISTING GROUND
STD. PG-2A DITCH
FACE OF P&P WALL
(HORIZONTAL CONTROL)
TOP OF WALL
WALL DAR-B: STA. 0+00 TO STA. 3+68.25
WALL DAR-C: STA. 0+00 TO STA. 4+18.00
SCALE: NONE
WX STEEL POST
BOTTOM OF WALL & TOP
OF SHAFT
4" DIA.
WEEP HOLE
PRECAST
CONCRETE PANEL
FINISHED GRADE
DRILLED SHAFT
STEEL POST
PILE SPACING (SEE PLANS AND PROFILES)
PARTIAL ELEVATION
STEEL PILE
CONCRETE SHAFT
(SEE NOTE 9)
Ø
THROUGH SHAFT
PRECAST
CONCRETE PANEL
PRECAST PANEL TO POST
CONNECTION DEVICE
PRECAST CONNECTION DETAIL
PANEL WIDTH
PILE SPACING (SEE PLANS AND PROFILES)
MIN 2.5' LAP
FOR PANELS
GEOTEXTILE DRAINAGE FABRIC
POROUS BACKFILL
PRECAST CONCRETE PANELS
SEE PRECAST CONNECTION
DETAIL
RETAINING WALL PARTIAL PLAN
POSSIBLE LOCATION OF
TEMPORARY SHEETING/SHORING
Sheets and Views
2G(1) RETAINING WALL NOTES AND DETAILS
File details come from the government source that posted it. Updated .