Plans Pg 7.pdf
PDF 2 MB Posted
- Solicitation number
- RFQ 171 180000000826 2
- Issued by
- Grand Traverse County, Kincheloe CDP, Michigan
About this file
This is an electrical demolition plan for the Pugsley Correctional Facility Lagoon Closure project in Fife Lake Township, Grand Traverse County, Michigan, under the Michigan Department of Corrections. The plan details the removal and demolition of electrical infrastructure associated with the wastewater treatment plant (WWTP), including seven existing conduits and associated junction boxes running from the maintenance building to the WWTP, WWTP leads and control equipment, lift pump station electrical systems, irrigation pump station electrical systems, and three light poles. The main electrical conduits at the maintenance building are to be cut and capped 2 feet below grade with the electrical panel removed. The contractor is responsible for field verification of the existing utilities, which are shown on the plan as approximate locations only, and must contact Miss Dig at 1-800-482-7171 or 811 at least three working days prior to construction start. The project references 2000 construction as-built drawings and requires verification that all energized conductors have been safely disconnected before demolition work begins.
The plan emphasizes that the contractor bears full responsibility for verifying the actual location and depth of all existing utilities prior to bidding, as the owner and surveyor assume no liability for omissions or variations from the locations shown. All electrical work must comply with safety protocols to ensure no energized conductors remain on any conduits being removed. The site electrical plan is provided on a not-to-scale basis and is intended as a reference document only, with contractors required to conduct thorough field verification before submitting bids.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Plans Pg 5.pdf | ||
| Addendum 1 (Plans 1 of 2).pdf | ||
| Addendum 1 (Plans 2 of 2).pdf | ||
| Plans Pg 3.pdf | ||
| Plans Pg 2.pdf | ||
| CAJ-1037 DOC LEIN Request REV 04-2018.pdf | ||
| Plans Pg 6.pdf | ||
| Plans Pg 8.pdf | ||
| Plans Pg 4.pdf | ||
| Specs.pdf | ||
| Plans Pg 1.pdf | ||
| Addendum 1.pdf | ||
| Advertisement.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
0'
1" =
SCALE
160' 320'
160'
Location:
P
C
A D
D D a t a
C
D
P
S i t e d w g
T a b
E
L E
C T
R I C
A L
D
E M
O L
I T
O N
S a v e d b y w c b o t t
M
P l o t t e d b y
E l i z a b e t h
P r i n c i n g
A
M e n g i n e e r i n g s c i e n c e s , i n c .
Project Number:
Checked By:
Drawn By:
Date Surveyed:
Scale:
Date Issued:
Designed By:
Original sheet size is 22x34
D a t e
N o
B y R e v i s i o n
1280 Business Park Dr.
Traverse City, Michigan
231-946-9191 phone info@goslingczubak.com www.goslingczubak.com
CIVIL ENGINEERING
SURVEYING
ENVIRONMENTAL SERVICES
GEOTECHNICAL
CONSTRUCTION SERVICES
DRILLING
LANDSCAPE ARCHITECTURE
2018660001.01
P U
G S
L E
Y
C
O R
R E
C T
I O
N A
L
F
A C
I L
I T
Y
L
A G
O O
N
C
L O
S U
R E
E L
E C
T R
I C
L
M
O L
I T
O N
M I C
H I G
N
P
A R
T M
E N
T
O
F
C
O R
R E
C T
I O
N S
Sheet:
SECTION 20
T 25N, R 09W
FIFE LAKE TOWNSHIP
GRAND TRAVERSE COUNTY
MICHIGAN
AS NOTED
WCB
ERP
GLW
N/A
08/06/2018
EXISTING OVERALL WWTP LAYOUT
SCALE : 1" = 160'
N O
R T
H
Know what's below.
before you dig.CallR
SITE ELECTRICAL PLAN
NOT TO SCALE
N O
R T
H
AutoCAD SHX Text MAIN ELECTRICAL CONDUITS LOCATED AT THE MAINTENANCE BUILDING SHALL BE CUT AND CONDUITS CAPPED 2' BELOW GRADE. PANEL TO BE REMOVED.
AutoCAD SHX Text THE LOCATION OF THE EXISTING UTILITIES, AS SHOWN ON THIS PLAN, ARE APPROXIMATE ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ACTUAL LOCATION AND DEPTH OF ALL EXISTING UTILITIES. THE OWNER AND THE SURVEYOR SHALL NOT BE RESPONSIBLE FOR ANY OMISSION OR VARIATION FROM THE LOCATION SHOWN. THE CONTRACTOR SHALL NOTIFY "MISS DIG" AT 1 (800) 482-7171 OR 811 THREE (3) WORKING DAYS PRIOR TO THE START OF CONSTRUCTION.
AutoCAD SHX Text DETAILS ON THIS SHEET ARE FROM THE 2000 CONSTRUCTION "AS-BUILT" DRAWINGS AND ARE INTENDED FOR REFERENCE ONLY. CONTRACTOR TO FIELD VERIFY PRIOR TO BIDDING.
AutoCAD SHX Text THE EXISTING SEVEN CONDUITS AND JUNCTION BOXES SHALL BE REMOVED IN ITS ENTIRETY, FROM THE MAINTENANCE BUILDING TO THE WWTP. IF THE DISCONNECT HAS SUCCESSFULLY COMPLETED, THERE SHOULD BE NO ENERGIZED CONDUCTORS ON THESE CONDUITS. THIS SHOULD BE VERIFIED BEFORE THIS WORK BEGINS.
AutoCAD SHX Text ALONG WITH REMOVING THE EXISTING SEVEN CONDUITS, THE WWTP LEADS AND CONTROL, ALONG WITH THE CONDUIT, CONDUCTORS AND EQUIPMENT ASSOCIATED WITH THE LIFT PUMP STATION AND THE IRRIGATION PUMP STATION AND (3) LIGHT POLES SHALL BE REMOVED IN THEIR ENTIRETY. IF THE DISCONNECT WAS SUCCESSFULLY COMPLETED, THERE SHOULD BE NO ENERGIZED CONDUCTORS ON THESE CONDUITS.
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text
APPROX. LOCATION LIGHT POLE (3)
File details come from the government source that posted it. Updated .