This is an as-built details sheet for the Pugsley Correctional Facility Lagoon Closure project prepared by the Michigan Department of Corrections in Grand Traverse County, Michigan. The document, dated August 6, 2018, provides technical reference drawings for the closure of an existing lagoon system at the correctional facility located in Fife Lake Township, Section 20, T 25N, R 09W. The sheet details various components requiring removal and abandonment, including an influent structure, lagoon liner, pipes, and an irrigation system. Key work items noted for contractor implementation include removal of the lagoon liner with pipes to be cut and capped per specifications, abandonment of an irrigation pump station in place, and removal of all irrigation system components with site restoration to be completed in accordance with project specifications. The document explicitly states that details provided are from 2000 construction as-built drawings and are for reference only, requiring contractors to field verify all conditions prior to bidding.

This technical reference sheet contains no pricing information, contract terms, set-asides, award dates, or funding details. The document serves primarily as a reference tool to inform bidders of existing site conditions and historical construction details that must be verified in the field before submitting bids. No response deadlines, site visit dates, or bidders' conferences are specified within this particular sheet, which is one page of a multi-page project plan set.

View the file

Other files

File Type Posted
Addendum 1 (Plans 1 of 2).pdf PDF
Addendum 1 (Plans 2 of 2).pdf PDF
Plans Pg 3.pdf PDF
Plans Pg 2.pdf PDF
CAJ-1037 DOC LEIN Request REV 04-2018.pdf PDF
Plans Pg 6.pdf PDF
Plans Pg 8.pdf PDF
Plans Pg 4.pdf PDF
Specs.pdf PDF
Plans Pg 1.pdf PDF
Addendum 1.pdf PDF
Plans Pg 7.pdf PDF
Advertisement.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Location:

P

C

A D

D D a t a

C

D

P

S i t e d w g

T a b

A

S B

U I L

T

D

E T

A I L

S

S a v e d b y w c b o t t

A

M l o t t e d b y

E l i z a b e t h r i n c i n g

A

M e n g i n e e r i n g s c i e n c e s , i n c .

Project Number:

Checked By:

Drawn By:

Date Surveyed:

Scale:

Date Issued:

Designed By:

Original sheet size is 22x34

D a t e

N o

B y R e v i s i o n

1280 Business Park Dr.

Traverse City, Michigan

231-946-9191 phone info@goslingczubak.com www.goslingczubak.com

CIVIL ENGINEERING

SURVEYING

ENVIRONMENTAL SERVICES

GEOTECHNICAL

CONSTRUCTION SERVICES

DRILLING

LANDSCAPE ARCHITECTURE

2018660001.01

P U

G S

L E

Y

C

O R

R E

C T

I O

N A

L

F

A C

I L

I T

Y

L

A G

O O

N

C

L O

S U

R E

A S

B

U I L

T

D

E T

A I L

S

M I C

H I G

A N

D

E P

A R

T M

E N

T

O

F

C

O R

R E

C T

I O

N S

Sheet:

SECTION 20

T 25N, R 09W

FIFE LAKE TOWNSHIP

GRAND TRAVERSE COUNTY

MICHIGAN

AS NOTED

WCB

ERP

GLW

N/A

08/06/2018

AutoCAD SHX Text FOR REFERENCE ONLY: INFLUENT STRUCTURE TO BE REMOVED. LINER TO BE REMOVED. PIPE TO BE CUT AND CAPPED PER SPECIFICATIONS.

AutoCAD SHX Text DETAILS ON THIS SHEET ARE FROM THE 2000 CONSTRUCTION "AS-BUILT" DRAWINGS AND ARE INTENDED FOR REFERENCE ONLY. CONTRACTOR TO FIELD VERIFY PRIOR TO BIDDING.

AutoCAD SHX Text FOR REFERENCE ONLY: LINER TO BE REMOVED. PIPE TO BE CUT AND CAPPED PER SPECIFICATIONS.

AutoCAD SHX Text

FOR REFERENCE ONLY: LINER TO BE REMOVED. PIPE TO BE REMOVED.

AutoCAD SHX Text

FOR REFERENCE ONLY: ALL IRRIGATION SYSTEM COMPONENT TO BE REMOVED.

AutoCAD SHX Text FOR REFERENCE ONLY: ALL IRRIGATION SYSTEM COMPONENTS TO BE REMOVED AND SITE RESTORED PER SPECIFICATIONS.

AutoCAD SHX Text FOR REFERENCE ONLY: IRRIGATION PUMP STATION TO BE ABANDONED IN PLACE PER SPECIFICATIONS.

AutoCAD SHX Text FOR REFERENCE ONLY: ALL IRRIGATION SYSTEM COMPONENTS TO BE REMOVED AND SITE RESTORED PER SPECIFICATIONS.