Pages 46 to 62 Drawings for 526-18-103 Replace Exterior Windows Phase 1.pdf

PDF 18 MB Posted

Attached to
Y1DZ--Project Number 526-18-103 Replace Exterior Windows, Phase 1 Federal contract opportunity
Solicitation number
36C24221B0069
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2

About this file

This notice is for a federal solicitation to replace exterior windows at the James J. Peters Veterans Affairs Medical Center in Bronx, New York. The solicitation number is 36C24221B0069 and has a Service-Disabled Veteran Owned Small Business set-aside. The project cost estimate is between $5 million and $10 million to replace existing exterior windows to create a new energy efficient and environmentally-friendly facility. The scope of work involves installing all new energy efficient windows using fall protection and following LEED protocols. The construction services will include fall protection, installing side light windows and window types W1 and W2. The contractor must verify all dimensions and reconfirm drawings and information from the architect engineer and Department of Veterans Affairs. The contract duration is 726 calendar days from receipt of the notice to proceed. The solicitation response deadline will be included in the solicitation document to be posted on December 31, 2021.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DZ--Project Number 526-18-103 Replace Exterior Windows, Phase 1, newest first.
File Type Posted
36C24221B0069 0005.docx DOCX document
36C24221B0069 0004.docx DOCX document
Copy of Equipments to be moved list Responses for RFI No. 1 and Related Questions to PreBid RFIs for 526-18-103.xlsx XLSX spreadsheet
Hazardous Material Survey Report Bronx Windows Phase 1 Nov 2020.pdf PDF
36C24221B0069 0003.docx DOCX document
099100 Painting Specification.pdf PDF
COVID Language.docx DOCX document
36C24221B0069 0002.docx DOCX document
Final Design Site Investigation-Window Survey Nov 2020.pdf PDF
Bronx Windows Phase 1 FINAL-Set1.pdf PDF
Bronx Windows Phase 1 FINAL-Set4.pdf PDF
Bronx Windows Phase 1 FINAL-Set6.pdf PDF
Bronx Windows Phase 1 FINAL-Set2.pdf PDF
36C24221B0069 0001.docx DOCX document
Bronx Windows Phase 1 FINAL-Set3.pdf PDF
Prebid Attendance Sheet for 526-18-103 Replace Exterior Windows Phase 1.pdf PDF
Bronx Windows Phase 1 FINAL-Set5.pdf PDF
Pages 1 to 20 Drawings for 526-18-103 Replace Exterior Windows Phase 1.pdf PDF
Pages 21 to 45 Drawings for 526-18-103 Replace Exterior Windows Phase 1.pdf PDF
36C24221B0069_1.docx DOCX document
Specification for 526-18-103 Replace Exterior Windows Phase 1.pdf PDF
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PER SPECIFICATION

SECTION 08 51 13 -

ALUMINUM WINDOWS:

WINDOWS TO INCLUDE

SUPPLEMENTAL KEYED GEM

LOCK

PER SPECIFICATION

SECTION 08 51 13 -

ALUMINUM WINDOWS:

WINDOWS ARE ABLE TO BE

OPERATED FOR CUSTODIAN

USE WITH CUSTODIAN KEY

ONLY.

IMPACT RATED WINDOW

HARDWARE DETAILS

AS409

JLSD

SECTION CALLOUTS

SCALE: NOT TO SCALE

NOTE:

WAUSAU IS THE BASIS OF DESIGN BUT IS NOT INTENDED TO LIMIT SELECTION.

HOLIHAN ASSOCIATES LLC

FINAL SUBMISSION

Bronx, New York

NOVEMBER 2020

Office of

Facility

Management

Service

REPLACE EXTERIOR WINDOWS PHASE 1

JAMES J. PETERS MEDICAL CENTER

BRONX, NEW YORK

526-18-103

Drawing TitleMedical Center Director Approval

Associate Director Approval

PCC Director Approval

Chief Engineer Approval

Safety Manager Approval

Chief Nurse Executive / Chief of Staff Approval Location

Drawing Number

Building Number

Project Title

Of

DrawnCheckedDate

Project Number

Dwg.

DESIGN CHANGE APPROVED

DESCRIPTION DATE

CONSULTANT FIRM ARCHITECTURAL ENGINEERING FIRM

311 FELS AVE. FAIRHOPE, AL 36532

NOTE:

ADDITIONAL ANCHORAGE OF EXISTING FRAMES TO

RESIST 2000 LB IMPACT LOADING WILL BE REQUIRED.

ADDITIONAL DEMOLITION MAY BE REQUIRED FOR

REINFORCMENT OF EXISTING WINDOW FRAMING.

INTERIOR STOOL TRIM

7 GA. STEEL SLIDE-IN ANCHORS

SIZES, QTY, LOCATION AS WELL

AS FASTENER SIZE AND SPACING

T.B.D. BY STRUCTURAL REVIEW

POCKET FILLED CONTINUOUS

WITH SEALANT PRIOR TO

WINDOW FRAME SETTING

t o

B l i n d

K n o b

VIEW OF FLUSH

MOUNT LOW-PROFILE

BLIND CONTROL KNOW

3/16 HEX KEY OPERATION

1/2

1" INSULATED

GLASS UNIT

NEW SILL FLASHING

OPTIONAL CONTINUOUS

ANTI-LIGATURE BAR

1/2" CLEAR MR10

POLYCARBONATE

EXISTING CEILING

TO REMAIN

ADDED STRUCTURE REQ'D

TO FILL HEAD AND PROVIDE

ADEQUATE ANCHORAGE FOR

WINDOW HEAD RECEPTOR

FASTENERS

@ 9" O.C.

PAINTED TO MATCH

FASTENERS &

WEEP HOOD

CONTINUOUS

CAP SEAL

TYPICAL AROUND

PERIMETER

CONTINUOUS CAP SEAL

W/HEADLESS WEDGE

ENSURE SEAL

COVERS JOINT

BETWEEN DRIVE-ON

& HEAD RECEPTOR

PER SPECIFICATIONS SECTION 08 51 13 - ALUMINUM

WINDOWS. CONDUCT A TEST IN GENERAL

ACCORDANCE WITH AAMA 501.8-13, TO SIMULATE 2000

LB. HUMAN IMPACT AS REQUIRED BY NYS OFFICE OF

MENTAL HEALTH. TEST UNIT IN REPORT SHALL BE

REPRESENTATIVE OF WINDOWS IN THE PROJECT IN

DETAILS OF FRAME CONNECTIONS, GLAZING AND

ANCHORAGE. TEST UNIT SHALL BE REPRESENTATIVE

OF THE LARGEST UNIT IN THE PROJECT IN BOTH WIDTH

AND HEIGHT.

IMPACT RATED WINDOW

HARDWARE DETAILS

AS410

JLSD

WINDOW DETAILS

SCALE: NOT TO SCALE

NOTE:

WAUSAU IS THE BASIS OF DESIGN BUT IS NOT INTENDED TO LIMIT SELECTION.

HOLIHAN ASSOCIATES LLC

FINAL SUBMISSION

Bronx, New York

NOVEMBER 2020

Office of

Facility

Management

Service

REPLACE EXTERIOR WINDOWS PHASE 1

JAMES J. PETERS MEDICAL CENTER

BRONX, NEW YORK

526-18-103

Drawing TitleMedical Center Director Approval

Associate Director Approval

PCC Director Approval

Chief Engineer Approval

Safety Manager Approval

Chief Nurse Executive / Chief of Staff Approval Location

Drawing Number

Building Number

Project Title

Of

DrawnCheckedDate

Project Number

Dwg.

DESIGN CHANGE APPROVED

DESCRIPTION DATE

CONTINUOUS CAULKING

REQUIRED

EXISTING 16 GA.

METAL PANEL ENCLOSURE

WITH INSULATION

EXISTING COVER TO REMAIN

W/ANCHORAGE BACK TO WALL

CONTINUOUS CAP SEAL

TYPICAL AROUND PERIMETER

16 3/4

3 1/210 1/162 1/8

15 13/16

1 1/16

ENSURE SEAL COVERS

JOINT BETWEEN DRIVE-ON

& JAMB RECEPTOR

5/8

IMPACT RATED WINDOW

HARDWARE DETAILS

AS411

JLSD

WINDOW DETAILS

SCALE: NOT TO SCALE

NOTE:

WAUSAU IS THE BASIS OF DESIGN BUT IS NOT INTENDED TO LIMIT SELECTION.

HOLIHAN ASSOCIATES LLC

FINAL SUBMISSION

Bronx, New York

NOVEMBER 2020

Office of

Facility

Management

Service

REPLACE EXTERIOR WINDOWS PHASE 1

JAMES J. PETERS MEDICAL CENTER

BRONX, NEW YORK

526-18-103

Drawing TitleMedical Center Director Approval

Associate Director Approval

PCC Director Approval

Chief Engineer Approval

Safety Manager Approval

Chief Nurse Executive / Chief of Staff Approval Location

Drawing Number

Building Number

Project Title

Of

DrawnCheckedDate

Project Number

Dwg.

DESIGN CHANGE APPROVED

DESCRIPTION DATE

3 1/2 8 1/4 3 1/2

15 1/2

EXISTING 16 GA.

FILLER PANELS

WITH INSULATION

CONTINUOUS CAULKING

REQUIRED

CONTINUOUS CAULKING

REQUIRED

CONCEALED 3 LEAF

BUTT HINGES

6 1/8

CONCEALED LOCKS

W/ESCUTCHEON PLATES

OPTIONAL TAMPERPROOF

LOCKS AVAILABLE

NEW PICK-PROOF CAULK

MAKE SURE GAP IS CAULKED

AT LEAST 1" ABOVE & BELOW

THE HEAD & SILL RECEPTOR

ESCUTCHEON PLATE

SIZE & SHAPE

3/4

5/8 5/8

5/8 5/8

M a x

O p e n i n g

CONCEALED LOCKS

W/ESCUTCHEON PLATES

OPTIONAL TAMPERPROOF

LOCKS AVAILABLE

IMPACT RATED WINDOW

HARDWARE DETAILS

AS412

JLSD

WINDOW DETAILS

SCALE: NOT TO SCALE

NOTE:

WAUSAU IS THE BASIS OF DESIGN BUT IS NOT INTENDED TO LIMIT SELECTION.

HOLIHAN ASSOCIATES LLC

FINAL SUBMISSION

Bronx, New York

NOVEMBER 2020

Office of

Facility

Management

Service

REPLACE EXTERIOR WINDOWS PHASE 1

JAMES J. PETERS MEDICAL CENTER

BRONX, NEW YORK

526-18-103

Drawing TitleMedical Center Director Approval

Associate Director Approval

PCC Director Approval

Chief Engineer Approval

Safety Manager Approval

Chief Nurse Executive / Chief of Staff Approval Location

Drawing Number

Building Number

Project Title

Of

DrawnCheckedDate

Project Number

Dwg.

DESIGN CHANGE APPROVED

DESCRIPTION DATE

CONSULTANT FIRM ARCHITECTURAL ENGINEERING FIRM

311 FELS AVE. FAIRHOPE, AL 36532

CONCEALED TAMPER RESISTANT LOCK

SCALE: NOT TO SCALE

STANDARD LOCKING MECHANISM

· REFERRED TO AS CONCEALED TAMPER RESISTANT LOCK THIS DRAWING (AS412)

· THIS IS THE STANDARD LOCK ON EVERY PSYCH WINDOW

· TAMPER RESISTANT VERSION (NOT JUST ANYBODY WITH A HEX OR ALLEN KEY COULD UNLOCK

THE WINDOW). THE TAMPER RESISTANT VERSION HAS A PIN IN THE CENTER OF THE

HEX/ALLEN KEY INSET AS SHOWN THIS DRAWING (AS412)

· THE ESCUTCHEON PLATE IS A NY OMH REQUIREMENT AND HAS THE SPECIAL KEY THAT IS

ALSO IN THE PICTURE TO KEEP THE KEY RETAINED IN THE OPENING UNTIL IT IS IN THE LOCKED

POSITION

BLIND KNOBS

· THE BLIND KNOB SHOWN IN PICTURE IS THE LOW PROFILE BLIND KNOB

· THIS KNOB HAS BEEN USED IN PSYCHIATRIC APPLICATIONS BUT IS GENERALLY NOT

ACCEPTABLE

· THE BLIND KNOB DETAILED IN THE DRAWINGS IS A FLUSH MOUNT LOW-PROFILE KNOB

· THIS CAN BE OPERATED BY THE OCCUPANT WITH THEIR FINGERS OR BY AN EMPLOYEE WITH A

3/16 HEX/ALLEN KEY

GEM/CAM LOCK

· REFERRED TO AS 1000 SERIES CAM LOCK THIS PAGE (AS412)

· NOT A STANDARD LOCK AND IS ONLY REQUIRED WHEN SPECIFIED

· THE GEM LOCK IS JUST AN ADDITIONAL LOCK FOR SECURITY, HAS A SPECIAL KEY SIMILAR TO

THAT YOU WOULD FIND ON A VENDING MACHINE. THIS LOCK IS NOT REQUIRED AND DOES NOT

HELP IN ANYWAY WITH THE HUMAN IMPACT LOAD.

GEM/CAM LOCK

SCALE: NOT TO SCALE

WINDOW SEQUENCE OF OPERATIONS

BOTH THE STANDARD AND THE PSYCHIATRIC RATED BOD WINDOWS OPERATE SIMILARLY.

FOLLOWING COMMON SEQUENCE OF OPERATION PROVIDED FOR INFORMATION.

NYC OMH REQUIRES: EACH WINDOW TO BE EQUIPPED WITH LOCKING POINTS THAT HAVE TO BE

UNLOCKED INDIVIDUALLY. THIS KEY MUST BE RETAINED IN THE LOCK WHEN IN THE UNLOCKED OR

OPEN POSITION. REMOVABLE ONCE RETURNED TO THE LOCKED OR CLOSED POSITION. THIS IS

ACCOMPLISHED WITH THE USE OF ESCUTCHEON PLATES AND SPECIAL KEYS.

OPERATING PROCEDURE BY STAFF:

1. INSERT ONE OF THE SPECIAL MADE KEYS WITH RETAINING PIN INTO EACH OF THE LOCKING

POINTS AND UNLOCK. RECOMMENDED TO USE TO USE TAMPERPROOF LOCK POINTS FOR ADDED

SECURITY.

2. IF OPTIONAL GEM LOCK IS USED THEN USE THE SPECIAL KEY TO UNLOCK. THIS LOCK DOESN’T

HAVE ANY ADDED STRUCTURAL PERFORMANCE AND ISN’T REQUIRED, JUST AN OPTIONAL LOCK TO

DETER OCCUPANT TAMPERING.

3. UNIT IS ABLE TO OPEN TO THE FULL OPEN POSITION OF APPROXIMATELY 75° FOR CLEANING

AND OR VENTING THE ROOM.

BLIND OPERATION:

1. WHEN THE WINDOWS SHOW UP TO THE FIELD THE BLINDS ARE IN THE “UP” POSITION AND WILL

NEED TO BE LOWERED PRIOR TO OCCUPANCY.

2. BLIND KNOBS CAN ONLY TILT THE BLINDS. RAISING AND LOWERING WOULD BE REQUIRED

WITH THE WINDOW IN THE UNLOCKED AND OPEN POSITION.

3. ROOM OCCUPANTS CAN TILT THE BLINDS WITH THEIR FINGERS, A LITTLE DIFFICULT BUT CAN

BE DONE.

4. STAFF CAN TILT THE BLINDS WITH EITHER THEIR FINGERS OR A 3/16” HEX/ALLEN KEY.

STANDARD WINDOW WITH LOCK STOP

1. CASEMENTS

a. LIFT LOWER 2-POINT KEEPER HANDLE AND OPEN

i. UPPER 2-POINT LUG WILL UNLOCK AT THE SAME TIME

b. WINDOW WILL STOP AT PRESET AND PREDETERMINED LIMITED OPENING

c. USE SPECIAL KEY TO RELEASE LIMITED OPENING DEVICES (LOD) FOR MAXIMUM OPENING

2. INSWING WINDOWS

a. UNLOCK EACH OF THE CAM HANDLES INDIVIDUALLY.

b. WINDOW WILL STOP AT PRESET AND PREDETERMINED LIMITED OPENING.

NON-IMPACT RATED WINDOW

HARDWARE DETAILS

AS413

JLSD

WINDOW DETAILS

SCALE: NOT TO SCALE

HOLIHAN ASSOCIATES LLC

FINAL SUBMISSION

Bronx, New York

NOVEMBER 2020

Office of

Facility

Management

Service

REPLACE EXTERIOR WINDOWS PHASE 1

JAMES J. PETERS MEDICAL CENTER

BRONX, NEW YORK

526-18-103

Drawing TitleMedical Center Director Approval

Associate Director Approval

PCC Director Approval

Chief Engineer Approval

Safety Manager Approval

Chief Nurse Executive / Chief of Staff Approval Location

Drawing Number

Building Number

Project Title

Of

DrawnCheckedDate

Project Number

Dwg.

DESIGN CHANGE APPROVED

DESCRIPTION DATE

CONSULTANT FIRM ARCHITECTURAL ENGINEERING FIRM

311 FELS AVE. FAIRHOPE, AL 36532

NON-IMPACT RATED WINDOW DETAIL

SCALE: NOT TO SCALE

NON-IMPACT RATED WINDOW DETAIL

SCALE: NOT TO SCALE

Bronx Windows Phase 1 FINAL-Set1.pdf
GI002-GIO02X.pdf
Sheets and Views
GIO02
Bronx Windows Phase 1 FINAL-Set2.pdf
Bronx Windows Phase 1 FINAL-Set3.pdf
Bronx Windows Phase 1 FINAL-Set4.pdf
Bronx Windows Phase 1 FINAL-Set5.pdf
Bronx Windows Phase 1 FINAL-Set6.pdf

File details come from the government source that posted it. Updated .