About this file

Attachment 2d - Option A Fort Wood Exterior Electrical Photos Drawings (5 pages)

View the file

Other files

File Type Posted
P17PS00002-000007_CWD-NY3_11-25-2016.pdf PDF
P17PS00002-000007_Amendment_signed.pdf PDF
P17PS00002-000007_Q As.pdf PDF
P17PS00002-000006_Q05-Attach_Poligon_Kiosk_Full_Plans.pdf PDF
P17PS00002-000006_Q As.pdf PDF
P17PS00002-000006_Amendment_signed.pdf PDF
P17PS00002-000004_Amendment_signed.pdf PDF
P17PS00002-000005_Amendment_signed.pdf PDF
204_P17PS00002_Reps_ _Certs.pdf PDF
P17PS00002-000003_Att-01_Pre-Bid_Clarifications.pdf PDF
P17PS00002-000003_Att-03_CWD-NY3_11-04-2016.pdf PDF
P17PS00002-000003_Amendment_Executed.pdf PDF
P17PS00002-000003_Att-02b_Revised_CPS-Clauses_ _Provisions.pdf PDF
P17PS00002-000003_Att-02a_Revised_CPS-Prop_Submission_Pkg.xlsx XLSX spreadsheet
P17PS00002_SF-1442_Solicitation_revised.pdf PDF
A15_CWD-NY3_10-21-2016.pdf PDF
P17PS00002-000002_Executed_Amendment.pdf PDF
P17PS00002_SF-1442_w-Constr_Clauses_ _Provisions.pdf PDF
B02_P17PS00002-000001_Amendment-Executed.pdf PDF
203_P17PS00002_Comb_Price_Schedule.pdf PDF
Att_01b_STLI_211177_Fence-Specs.pdf PDF
Att_02c_STLI_201065-Approach_Mall-Combined_Set.pdf PDF
101_P17PS00002_Experience_Form.docx DOCX document
207_P17PS00002_ProposedEquals.docx DOCX document
Att_04a_P17PS00002_Q As_10-13-2016.pdf PDF
100_P17PS00002_Sol_Cover_Sheet-Tech_Proposal.pdf PDF
00_P17PS00002_Competitive_Constr._Prop._Subm._Pkg.pdf PDF
202_P17PS00002_SF-1442_Solicitation.pdf PDF
Att_02b_02_STLI_201065-Main_Mall-Combined_Set.pdf PDF
Att_01a_STLI_211177-201065-Div_1_Specs.pdf PDF
Att_01c_STLI_201065_Main_Mall-Specs.pdf PDF
Att_04b_STLI_201065_Pre-Bid_Clarifications_07.19.16.pdf PDF
206_P17PS00002_HazmatForm.docx DOCX document
201_SF_24_Bid_Bond.pdf PDF
Att_03_DVB_Gen_Decision_No_NY3_NYCO_10-07-2016.pdf PDF
Att_02e_Opt_B_Audio_Kiosk_Relocation.pdf PDF
205_P17PS00002_GeneralReferences.docx DOCX document
105_P17PS00002_Performance_Questionnaire.docx DOCX document
203_P17PS00002_Comb_Price_Schedule.xls XLS spreadsheet
200_P17PS00002_Sol_Cover_Sheet-Bus_Proposal.pdf PDF
103_P17PS00002_Key_Personnel_Form.docx DOCX document
Att_02a_STLI_211177-Combined_Set.pdf PDF
Att_01d_STLI_201065_Approach_Mall-Specs.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Option A – Fort Wood Exterior Electrical

Sallyport Walk Electrical Outlet o Install new, waterproof, exterior grade duplex GFCI outlet inside the existing 24” x 24” quazite box.

o Pull 500’ of new 4 gage wire thru the existing conduit and terminate at the available electrical panel.

o Circuit shall be 20 amp o Provide all labor and materials required to complete the work.

Remove 13 Existing (11” x 21”) In‐ground Spot Lights o Confirm all power connections are dead.

o Lights are approximately 15” deep.

o Disconnect and remove all 13 fixtures and secure and cap all wires.

o Fill all holes to grade with approximately 10” of ¾” clean aggregate, 3” of topsoil and new sod.

o When work is completed, ensure grade matches existing with no settling.

o Coordinate sod location with CMR to obtain sod from same supplier as original lawn.

o Provide all labor and materials required to complete the work.

Existing 24”x24” Quazite Box

Existing In‐Ground Spot Lights (Typ)

Existing Fort Wood exterior lighting, recessed into grade (in background)

Existing Fort Wood exterior lighting, recessed into grade

Existing Fort Wood exterior lighting, recessed into grade

MKutch Rectangle

MKutch Rectangle

MKutch Rectangle

MKutch Polygon

MKutch Polygon

MKutch Polygon

MKutch Polygon

MKutch Typewritten Text

OPTION A - FORT WOOD EXTERIOR ELECTRICAL

MKutch Rectangle

MKutch Rectangle

MKutch Rectangle

MKutch Rectangle

MKutch Rectangle

MKutch Rectangle

MKutch Rectangle

MKutch Rectangle

MKutch Rectangle

MKutch Rectangle

MKutch Rectangle

MKutch Rectangle

MKutch Rectangle

MKutch Rectangle

MKutch Typewritten Text

EXISTING IN-GROUND SPOT LIGHTS (TO BE REMOVED) (TYP) (13 LIGHTS)

MKutch Rectangle

MKutch Rectangle

MKutch Typewritten Text

MKutch Typewritten Text EXISTING 24"x24" QUAZITE BOX (TO REMAIN)

MKutch Line

MKutch Typewritten Text

EXISTING ELEC CONDUIT

MKutch Rectangle

MKutch Line

File details come from the government source that posted it. Updated .