OKC B-Mod Drawings.pdf

PDF 34 MB Posted

Attached to
Z2DA--635-19-101 Renovate B-Mod Construction (plus up) (VA-22-00016600)
Solicitation number
36C25922R0012
Issued by

About this file

This document provides details for a federal solicitation to renovate a B-Mod construction project for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19. Solicitation number 36C25922R0012 seeks proposals to complete Z2DA--635-19-101 Renovate B-Mod Construction (plus up) for VA-22-00016600. Interested parties should review attachment 4.23 for additional requirements. Proposals are due by the date specified in the solicitation to upgrade and expand modular buildings for a Veterans Affairs medical facility.

View the file

Other files

File Type Posted
36C25922R0012 0008.docx DOCX document
36C25922R0012 0008.docx DOCX document
36C25922R0012 0007.docx DOCX document
36C25922R0012 0006.docx DOCX document
36C25922R0012 0005.docx DOCX document
Product Data Sheets.pdf PDF
SECTION 03 30 00 Cast in Place Concrete.docx DOCX document
013216.15 PROJECT SCHEDULES.pdf PDF
080671_Door_Hardware_Schedule_2022-01-21.pdf PDF
VA02821319-Floor tile and Mastic OK VA(rev).docx DOCX document
09 68 00 CARPETING .pdf PDF
OKC PACT Renovation AE601.pdf PDF
105126.18 Solid Plastic Lockers (3).pdf PDF
Hollow Metal Doors and Frames.pdf PDF
087113_Automatic_Door_Operators.pdf PDF
36C25922R0012 0004.docx DOCX document
OKC PACT Renovation Updated Drawings Final.pdf PDF
092400 PORTLAND CEMENT PLASTER.pdf PDF
Asbestos Building 1 Inventory.xlsx XLSX spreadsheet
2020-0647.20 F1 ACM 1-20-2022.pdf PDF
122400 Window Shades.pdf PDF
275223 - Nurse Call Systems.pdf PDF
14 92 00 PNEUMATIC TUBE SYSTEM.pdf PDF
Integrated Access Control Hardware Devices.pdf PDF
092513.13 ACRYLIC PLASTER FINISH.pdf PDF
087100_Door_Hardware.pdf PDF
090600-SCHEDULE OF FINISHES (1).pdf PDF
36C25922R0012 0003.docx DOCX document
Pre-Bid Site Walk Attendance sheet.pdf PDF
36C25922R0012 0002.docx DOCX document
36C25922R0012 0001.docx DOCX document
36C25922R0012_1.docx DOCX document
3 10 2021 Past Performance Questionnaire.docx DOCX document
OKC B-Mod Specifications.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWING LIST

1i

0 GRID / COLUMN LINE DESIGNATOR

EQUIPMENT NUMBER

DOOR NUMBER

Ga5xFB1

WALL TYPE

WINDOW TYPE

ROOM NAME

ROOM NAME / NUMBER

REVISION TAG

PLAN NORTH

NORTH ARROW WITH TRUE

NORTH INDICATION

EGRESS ROUTE ID AND

SECTION LENGTH

ROOM

ROOM OCCUPANCY

150 SF

EGRESS : EGRESS ID

Egress Length

ROOM OCCUPANCY & AREA

ELEVATION NUMBER

SECTION

INTERIOR ELEVATION

ENLARGEMENT,

DETAIL

SPOT ELEVATION

Name Elevation

FLOOR LEVEL &

NAME

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

SHEET KEYNOTE

A101

SIM

EXTERIOR ELEVATION

A-101

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

INDEX OF DRAWINGS

01-A101

DISCIPLINE:

G - GENERAL

A - ARCHITECTURE

F - FIRE PROTECTION

P - PLUMBING

M - MECHANICAL

E - ELECTRICAL

SHEET TYPE

DESIGNATOR

VICINITY MAP

PROJECT TEAM

BUILDING SUMMARY

PROJECT INFORMATION

THE SCOPE OF THIS PROJECT IS TO DEVELOP FULL DESIGN-BID-BUILD PACKAGE TO DEMOLISH AND RENOVATE APPROXIMATELY 6,330 SQ. FT. OF EXISTING CLINICAL SPACE WITHIN BUILDING 1, GROUND LEVEL, AT THE OKCVA MEDICAL CENTER INCORPORATING THE MOST CURRENT VERSION OF THE VA’S PACT SPACE MODULE DESIGN GUIDE AND INDUSTRY

BEST PRACTICES.

ANNOTATION DRAWING SYMBOLSGENERAL NOTES

PROJECT NAME:

PROJECT NUMBER:

PROJECT LOCATION:

BUILDING NUMBER

1. THESE DRAWINGS SHALL BE USED ONLY FOR THIS SPECIFIC PROJECT/SITE LOCATION. THESE DRAWINGS ARE A COMPOSITE SET OF CONTRACT DOCUMENTS AND SHALL NOT BE SEPARATED FOR DISTRIBUTION. THE GC SHALL REVIEW

ALL DRAWINGS AND PROVIDE/DISTRIBUTE THE ENTIRE SET TO EACH SUBCONTRACTOR.

2. THE GC SHALL VISIT THE SITE TO INSPECT EXISTING CONDITIONS AND VERIFY WORK BEING PERFORMED BEFORE

SUBMITTING COST QUOTATIONS FOR WORK.

3. NOTIFY THE ARCHITECT PROMPTLY OF ANY ERRORS, OMISSIONS, INCONSISTENCIES, DISCREPANCIES AND CONFLICTS WITHIN THE CONTRACT DOCUMENTS AND ITS ASSOCIATED FIELD/PROJECT CONDITIONS SO THAT A RESOLUTION CAN BE

PROVIDED PRIOR TO CONTINUING WITH WORK.

4. DO NOT SCALE THE DRAWINGS. REQUEST ANY MISSING DIMENSIONS FROM THE ARCHITECT

5. ALL WORK PERFORMED SHALL BE IN STRICT COMPLIANCE WITH GOVERNING FEDERAL, STATE AND LOCAL BUILDING CODE REQUIREMENTS, SHALL BE EXECUTED IN ACCORDANCE WITH ACCEPTED INDUSTRY STANDARDS, AND SHALL CONFORM TO SPECIFIC REGULATIONS AS MANDATED BY THE OWNER, THE ARCHITECT, AND THE AUTHORITIES HAVING JURISDICTION.

THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ANY FEES ASSOCIATED WITH PROCURING SUCH PERMITS AND CERTIFICATES AND SHALL FURNISH COPIES OF PERMITS, INSPECTIONS, AND CERTIFICATES TO THE OWNER.

6. THE GENERAL CONTRACTOR SHALL COORDINATE ALL WORK TO MINIMIZE DISRUPTION OF OF ANY EXISTING TENANTS OR BUILDING OPERATIONS. THE GENERAL CONTRACTOR SHALL TAKE ADEQUATE PRECAUTIONS TO PROTECT BUILDING OCCUPANTS, MATERIALS, AND EXISTING CONSTRUCTION THROUGHOUT ALL PHASES OF CONSTRUCTION. DAMAGE TO EXISTING-TO-REMAIN CONSTRUCTION OR EQUIPMENT SHALL BE RESTORED TO ORIGINAL CONDITION AT THE

CONTRACTOR'S EXPENSE.

7. THE GENERAL CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE JOB SITE ON A DAILY BASIS.

8. ANY REQUESTS FOR SUBSTITUTIONS OF ANY SPECIFIED ITEM ARE TO BE SUBMITTED TO THE ARCHITECT IN WRITING AND WILL BE CONSIDERED ONLY IF THE ALTERNATE PROPOSED IS PROVEN TO BE ADVANTAGEOUS TO THE OWNER WITH

RESPECT TO DELIVERY DATE, QUALITY, OR COST.

9. THE MEANS AND METHODS OF CONSTRUCTION, AND TEMPORARY STRUCTURES AND FACILITIES, ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE ARCHITECT DOES NOT ASSUME ANY RESPONSIBILITY FOR THE CONTRACTOR'S

MEANS AND METHODS OR FOR TEMPORARY STRUCTURES.

10. DEMOLITION OF EXISTING STRUCTURES IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE CONTRACTOR SHALL

EMPLOY ENGINEERING EXPERTISE AS NEEDED TO ASSIST IN DEMOLITION.

11. JOB SITE SAFETY AND SECURITY ARE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR SHALL CONSULT WITH LOCAL FIRE AUTHORITIES TO ASCERTAIN REQUIREMENTS FOR FIRE SUPPRESSION AND SAFETY DURING CONSTRUCTION. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR MEETING OSHA

REGULATIONS DURING CONSTRUCTION.

12. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR STORAGE AND PROTECTION OF BUILDING MATERIALS, AND INSTALLED CONSTRUCTION, FROM INCLEMENT WEATHER, THEFT, AND OTHER HAZARDS. THE GC SHALL FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS FOR STORAGE OF MATERIALS. PARTIALLY COMPLETED WALLS SHALL BE COVERED TO PROTECT FROM WATER INTRUSION. DAMAGE, INCLUDING BUT NOT LIMITED TO MOLD, RESULTING FROM WATER INTRUSION DURING CONSTRUCTION SHALL BE REPAIRED AT THE GENERAL CONTRACTOR'S EXPENSE.

A101

A101

SCOPE OF WORK SUMMARY:

SHEET NUMBER

WITHIN SERIES

REMODEL B MOD OKLAHOMA VAMC

635-19-101

OKLAHOMA CITY DEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTER

921 N.E. 13TH STREET

OKLAHOMA CITY, OK 73104

Romanyk Consulting Focusing on what matters

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

VA FORM 08 - 6231

F

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

8910 7 6 5 4 3 2 1

U.S. Department of Veterans Affairs

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

U.S. Department of Veterans Affairs

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Spinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

B

IM

/V

IS

N

O k la h o m a C it y P

A C

T R e n o v a ti o n /O k la h o m a C it y P

A C

T R e n o v a ti o n .r v t

/2

/2

:4

:4

P

M

PROJECT NUMBER - 635-19-101

REMODEL B MOD OKLAHOMA VAMC - OKLAHOMA CITY, OK

100% CONTRACT DOCUMENTS

SEPTEMBER 24, 2021

BW LJ

635-19-101

GI100

635 - OKLAHOMA CITY, OK

SEPTEMBER 24, 2021

01-

SHEET INDEX & GENERAL INFORMATION 100% CONTRACT DOCUMENTS REMODEL B MOD OKLAHOMA VAMC

- OKLAHOMA CITY, OK

SHEET # SHEET TITLE

PLUMBING

P-001 PLUMBING SYMBOLS, NOTES, AND ABBREVIATIONS

PD100 PARTIAL BASEMENT FLOOR PLAN - PLUMBING DWV DEMOLITION

PD101 PARTIAL GROUND FLOOR PLAN - PLUMBING DWV DEMOLITION

PD201 PARTIAL GROUND FLOOR PLAN - PLUMBING DISTRIBUTION DEMOLITION

PP100 PARTIAL BASEMENT FLOOR PLAN - PLUMBING DWV

PP101 PARTIAL GROUND FLOOR PLAN - PLUMBING DWV

PP200 PARTIAL BASEMENT FLOOR PLAN - PLUMBING DISTRIBUTION

PP201 PARTIAL GROUND FLOOR PLAN - PLUMBING DISTRIBUTION

PP300 PLUMBING RISER DIAGRAM - DWV

PP301 PLUMBING RISER DIAGRAM - PLUMBING DISTRIBUTION

P-400 PLUMBING DETAILS & SCHEDULES

MECHANICAL

M-001 MECHANICAL SYMBOLS, NOTES, AND ABBREVIATIONS

MD101 PARTIAL GROUND FLOOR PLAN - HVAC DEMOLITION

MD102 PARTIAL LEVEL 03 FLOOR PLAN - HVAC DEMOLITION

MD201 PARTIAL GROUND FLOOR PLAN - PIPING DEMOLITION

MH101 PARTIAL GROUND FLOOR PLAN - HVAC

MH102 PARTIAL LEVEL 03 FLOOR PLAN - HVAC

MH200 MECHANICAL HVAC DETAILS

MH300 MECHANICAL HVAC SCHEDULES

MH301 MECHANICAL HVAC SCHEDULES

MI101 PARTIAL GROUND FLOOR PLAN - MECHANICAL INSTRUMENTATION

MI301 MECHANICAL INSTRUMENTATION - SEQUENCES OIT TR UNIT

MI302 MECHANICAL INSTRUMENTATION - SEQUENCES VAV - HW REHEAT

MI303 MECHANICAL INSTRUMENTATION - SEQUENCES EXHAUST FAN - ON/OFF

MP102 PARTIAL LEVEL 03 FLOOR PLAN - PIPING

MP101 PARTIAL GROUND FLOOR PLAN - PIPING

MP200 MECHANICAL PIPING DETAILS

ELECTRICAL

E-001 ELECTRICAL SYMBOLS, NOTES, AND ABBREVIATIONS

ED101 PARTIAL GROUND FLOOR PLAN - ELECTRICAL DEMOLITION

EL101 PARTIAL GROUND FLOOR PLAN - LIGHTING

EP100 BASEMENT LEVEL FLOOR PLAN - CONDUIT ROUTING

EP101 PARTIAL GROUND FLOOR PLAN - POWER

EP102 GROUND FLOOR PLAN - CONDUIT ROUTING

EP103 PARTIAL LEVEL 3 FLOOR PLAN - MECHANICAL POWER

EP104 PARTIAL LEVEL 09 FLOOR PLAN - ELECTRICAL

ES101 PARTIAL GROUND FLOOR PLAN - TECHNOLOGY SYSTEMS

E-400 ENLARGED PLANS - ELECTRICAL

E-500 ELECTRICAL DETAILS

E-700 ELECTRICAL SCHEDULES

SHEET # SHEET TITLE

GENERAL

GI100 SHEET INDEX & GENERAL INFORMATION

GI101 ABBREVIATIONS & SYMBOLS

GI102 ADA INFORMATION

GI103 BUILDING CODE DATA

GI104 LIFE SAFETY PLAN

GI105 GROUND FLOOR PHASING PLAN

HAZARDOUS MATERIALS

HA101 ASBESTOS ABATEMENT PLAN

ARCHITECTURAL

AD100 PARTIAL GROUND FLOOR - DEMOLITION PLAN

AD101 REFLECTED CEILING PLAN DEMOLITION PLAN

AD102 BASEMENT DEMO REFLECTED CEILING PLAN

AE101 OVERALL GROUND FLOOR

AE102 PARTIAL GROUND FLOOR - ENLARGED FLOOR PLAN

AE103 DIMENSION PLAN

AE104 REFLECTED CEILING PLAN

AE401 ENLARGED TOILET PLANS AND ELEVATIONS

AE402 ENLARGED TOILET PLANS AND ELEVATIONS

AE403 ENLARGED PLANS & ELEVATIONS

AE404 ENLARGED PLANS

AE405 INTERIOR ELEVATIONS

AE500 WALL TYPES

AE501 ACCESSIBLE DETAILS

AE502 INTERIOR DETAILS

AE503 METAL STUD DETAILS

AE504 CEILING DETAILS SUSPENDED GYPSUM

AE601 DOOR & WINDOW SCHEDULES

AE701 CASEWORK SECTIONS AND DETAILS

AE702 CASEWORK SECTIONS AND DETAILS

AF101 GROUND FLOOR FINISH PLAN AND SCHEDULE

AW101 GROUND FLOOR SIGNAGE PLAN

AW102 SIGNAGE PLAN DETAILS

AW103 SIGNAGE PLAN DETAILS

QH101 PARTIAL GROUND FLOOR - EQUIPMENT PLAN

SPRINKLER

FS001 SPRINKLER SYMBOLS, NOTES, DETAILS, AND ABBREVIATIONS

FD101 PARTIAL GROUND FLOOR PLAN - SPRINKLER DEMOLITION

FS101 PARTIAL GROUND FLOOR PLAN - SPRINKLER

OWNER:

Oklahoma City VA Health Care System 921 NE 13th Street Oklahoma City, OK 73104

John Wilson John.Wilson3@va.gov

405-456-3922 520-400-1202 cell

15 SUNNEN DR SUITE 104

SAINT LOUIS, MO 63143

314.645.1132 FAX: 314.645.1173

www.imegcorp.com # 17002665.02

PROJECT ARCHITECT:

Romanyk Consulting Corp.

3308 Preston Road, Suite 350-164 Plano, Texas 75093

Barrett Webb Barrett.Webb@RomaynkConsulting.com

855-424-3838 x318 512-413-6963 cell

HAZARDOUS MATERIALS:

SCI Engineering 130 Point West Blvd.

St. Charles MO 63301

Glen Grissom, Project Scientist @sciengineering.com

636-949-8200

ELECTRICAL ENGINEER:

Romanyk Consulting Corp.

3308 Preston Road, Suite 350-164 Plano, Texas 75093

Jonathan Foster, PE, LEED AP Jonathan.Foster@RomanykConsulting.com

855.424.3838 x307

501.428.4167 cell

MECHANICAL ENGINEER:

Romanyk Consulting Corp.

3308 Preston Road, Suite 350-164 Plano, Texas 75093

Arlo Wieczorek, PE Arlo.Wieczorek@RomanykConsulting.com

855.424.3838 x324

319.721.4986 cell

PLUMBING ENGINEER:

Romanyk Consulting Corp.

3308 Preston Road, Suite 350-164 Plano, Texas 75093

Arlo Wieczorek, PE Arlo.Wieczorek@RomanykConsulting.com

855.424.3838 x324

319.721.4986 cell

FIRE PROTECTION ENGINEER:

Romanyk Consulting Corp.

3308 Preston Road, Suite 350-164 Plano, Texas 75093

Scott Thraen, PE Scott.Thraen@RomanykConsulting.com

855.424.3838 x312

402.981.8882 cell

Revisions: Date:

ACCESSIBLE SIGNAGE REQS

LETTER AND NUMBER HEIGHTS

TOILET ACCESSORY LEGEND

NOTES

1i

0 GRID / COLUMN LINE DESIGNATOR

EQUIPMENT NUMBER

DOOR NUMBER

Ga5xFB1

WALL TYPE

WINDOW TYPE

ROOM NAME

ROOM NAME / NUMBER

REVISION TAG

PLAN NORTH

NORTH ARROW WITH TRUE

NORTH INDICATION

EGRESS ROUTE ID AND

SECTION LENGTH

ROOM

ROOM OCCUPANCY

150 SF

EGRESS : EGRESS ID

Egress Length

ROOM OCCUPANCY & AREA

ELEVATION NUMBER

SECTION

INTERIOR ELEVATION

ENLARGEMENT,

DETAIL

SPOT ELEVATION

Name Elevation

FLOOR LEVEL &

NAME

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

SHEET KEYNOTE

A101

SIM

EXTERIOR ELEVATION

A-101

PLATE NUMBER WHERE

SECTION/DETAIL IS DRAWN

A101

A101

ANNOTATION DRAWING SYMBOLS

INDEX OF DRAWINGS

202-A101

DISCIPLINE:

G - GENERAL

A - ARCHITECTURE

I - INTERIORS

F- FIRE PROTECTION

P - PLUMBING

M - MECHANICAL

E - ELECTRICAL

T - TELECOM

V - VENTILATION

SHEET TYPE

DESIGNATOR

BUILDING NUMBER

SHEET NUMBER

WITHIN SERIES

ARCHITECTURAL SYMBOLS

LEGEND

CONCRETE/ PRECAST

CONCRETE

SOIL

SAND, EIFS FINISH COAT,

OR CEMENT PLASTER

BRICK

CMU

STONE

FIBERGLASS BATT

INSULATION

EXPANDED POLYSTYRENE

RIGID INSULATION

EXTRUDED POLYSTYRENE

RIGID INSULATION

POLYISOCYANURATE RIGID

INSULATION

GYPSUM BOARD

EXTERIOR GYPSUM

SHEATHING

EXTERIOR CEMENT

BOARD

COATED GLASS MAT

WATER RESISTANT

GYP BD

PLYWOOD

COVER BOARD

MATERIALS

CEILING SYMBOLS

MECHANICAL SUPPLY DIFFUSER

MECHANICAL RETURN GRILLE

MECHANICAL EXHAUST GRILLE

24" X 24" ACOUSTICAL CEILING

PANEL AND GRID

GYPSUM BOARD CEILING OR

SOFFIT

2' x 2' LED FLUORESCENT

FIXTURE - EMERGENCY NIGHT

LIGHT

RECESSED CAN DOWNLIGHT

CEILING ELEVATION A.F.F.X'-X"

EXIT SIGN

LED LIGHT

1' x 4' LED FLUORESCENT

FIXTURE

2' x 4' LED FLUORESCENT

FIXTURE

INDUSTRIAL LUMINAIRE

EMERGENCY LIGHT

2' x 2' LED FLUORESCENT

FIXTURE

OC

NURSE CALL DOME LIGHT WALL

MOUNTED

A

FIRE ALARM AUDIO/VISUAL

NOTIFICATION DEVICE-CEILING

MOUNTED.

CAM

LS

OCCUPANCY SENSOR

A1 A3

DAYLIGHT LEVEL SENSOR

CLOSED CIRCUIT CAMERA (CCTV)

CEILING MOUNTED

N

S SPEAKER

CLOSED CIRCUIT CAMERA (CCTV)CAM

VC VACANCY SENSOR

WAP CEILING INFORMATION OUTLET

FIRE ALARM VISUAL NOTIFICATION

DEVICE - WALL MOUNTED

V1

WALL CONTROL STATIONSW

NURSE CALL STATIONN

SMOKE,FIRE/SMOKE

DAMPER CONTROLLER

ARD

FIRE ALARM MANUAL PULL

STATION

F

FIRE ALARM SMOKE,

SMOKE DAMPER

SD

SD FIRE ALARM DUCT SMOKE

DETECTOR

D DIMMER LED

A FIRE ALARM AUDIO/VISUAL

NOTIFICATION DEVICE- WALL

MOUNTED.

A1 A3

S SWITCH

{LD}

{LS}

LIGHT DIMMER

LIGHT SENSOR

ARCHITECTURAL DRAWING ABBREVIATIONS

A ---------------------

A LABEL CLASS A DOOR

A/C AIR CONDITION

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AB ANCHOR BOLT

ACC ACCESSIBLE

ACS AUTOMATIC CONTROL SYSTEM

ACS DR ACCESS DOOR

ACS PNL ACCESS PANEL

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

ADMIN ADMINISTRATION

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SLAB

AGGR AGGREGATE

AHU AIR HANDLING UNIT

AIB AIR INFILTRATION BARRIER

ALT ALTERNATE

ALG ALUMINUM AND GLASS

AL ALUMINUM

ALUM ALUMINUM

ANOD ANODIZE

APC ACOUSTICAL PANEL CEILING

APPROX APPROXIMATE

AR AS REQUIRED

ARCH ARCHITECT

ASC ABOVE SUSPENDED CEILING

ASSY ASSEMBLY

ATC ACOUSTICAL TILE CEILING

AVG AVERAGE

AW ARCHITECTURAL WOODWORK

AWT ACOUSTICAL WALL TREATMENT

B ---------------------

B LABEL CLASS B DOOR

BALC BALCONY

BB BASEBOARD

BC BOOKCASE

BD BOARD

BDRY BOUNDARY

BFF BELOW FINISH FLOOR

BHMA BUILDER'S HARDWARE MANUFACTURER'S ASSOCIATION

BLDG BUILDING

BLKG BLOCKING

BLT IN BUILT-IN

BN BULLNOSE

BOS BOTTOM OF STEEL

BOT BOTTOM

BP BUILDING PAPER

BRKT BRACKET

BSMT BASEMENT

BTWN BETWEEN

BUR BUILT-UP ROOFING

C ---------------------

C CONC CAST CONCRETE

C LABEL CLASS C DOOR

CAB CABINET

CATW CATWALK

CAV CAVITY

CBB CEMENTITIOUS (BACKER) BOARD

CD CONSTRUCTION DOCUMENTS

CDW CHILLED DRINKING WATER

CEM PLAS CEMENT PLASTER

CER CERAMIC

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

CFE CONTRACTOR FURNISHED EQUIPMENT

CFLG COUNTERFLASHING

CFM CUBIC FEET PER MINUTE

CFMF COLD-FORMED METAL FRAMING

CFS CUBIC FEET PER SECOND

CG CORNER GUARD

CI CAST IRON

CIP CAST-IN-PLACE

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLG DIFF CEILING DIFFUSER

CLG HT CEILING HEIGHT

CLL COLUMN LINE

CLO CLOSET

CLR COLOR

CLRM CLASSROOM

CMU CONCRETE MASONRY UNIT

CNDS CONDENSATE

CDR CARD READER

CO CLEANOUT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONC FLR CONCRETE FLOOR

CONF CONFERENCE

CONT CONTINUE

COORD COORDINATE

CORR CORRIDOR

CP CONCRETE PIPE

CPT CARPET

CR CONTROL ROOM

CS CAST STONE

CSWK CASEWORK

CT CERAMIC TILE

CTB CERAMIC TILE BASE

CTF CERAMIC TILE FLOOR

CTR CENTER

CU FT CUBIC FEET

CW CASEMENT WINDOW

D ---------------------

D DEPTH

D LABEL CLASS D DOOR

DBL DOUBLE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DIA DIAMETER

DIR DIRECTION

DIST DISTANCE

DOC DOCUMENT

DR DOOR

DS DOWNSPOUT

E ---------------------

E LABEL CLASS E DOOR

EA EACH

EF EACH FACE

EIFS EXTERIOR INSULATION AND FINISH SYSTEM

EJ EXPANSION JOINT

ES EACH SIDE

EL ELEVATION

ELEC ELECTRICAL

ELEV ELEVATOR

ELEV EQ ELEVATOR EQUIPMENT

ENTR ENTRANCE

EPS EXPANDED POLYSTYRENE BOARD (INSULATION)

EQ EQUAL

EWC ELECTRIC WATER COOLER

EXP EXPOSED

EXT EXTERIOR

EXT EXTINGUISHER

EXT GR EXTERIOR GRADE

F ---------------------

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FAS BD FASCIA BOARD

FC BRK FACE BRICK

FCO FLOOR CLEANOUT

FD FLOOR DRAIN

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FED FEDERAL

FF FINISH FACE

FF EL FINISH FLOOR ELEVATION

FF INSUL FOIL BACKED INSULATION

FGL FIBERGLASS

FH FIRE HOSE

FHP FULL HEIGHT PARTITION

FIN FINISH

FIN BS FINISH BOTH SIDES

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

FIXT FIXTURE

FLDG FOLDING

FLEX FLEXIBLE

FLG FLOORING

FLMT FLUSH MOUNT

FLR FLOOR

FM FACTORY MUTUAL

FOC FACE OF CONCRETE

FOM FACE OF MASONRY

FR FIRE RESISTANT

FRG FIBER REINFORCED GYPSUM

FRMG FRAMING

FRP FIBERGLASS REINFORCED PLASTIC

FRTW FIRE RETARDANT TREATED WOOD

FS FEDERAL SPECIFICATION

FSTNR FASTENER

FT FEET

FTG FOOTING

FWC FABRIC WALLCOVERING

G ---------------------

G NATURAL GAS

GALV GALVANIZED

GB GRAB BAR

GFCI GOVERNMENT FURNISHED CONTRACTOR INSTALLED

GFGI GOVERNMENT FURNISHED INSTALLED BY GOVERNMENT

GFRG GLASS-FIBER-REINFORCED GYPSUM

GLZ GLAZING

GR FL GROUND FLOOR

GSF GROSS SQUARE FEET

GUT GUTTER

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

H ---------------------

HAC HOUSE AID KEEPING CLOSET

HB HOSE BIBB

HDPE HIGH DENSITY POLYETHYLENE

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HMF HOLLOW METAL FRAME

HORIZ HORIZONTAL

HR HOUR

HT HEIGHT

HVAC HEATING, VENTILATION, AND AIR CONDITIONING

HYDR HYDRAULIC

I ---------------------

IBC INTERNATIONAL BUILDING CODE

INSUL INSULATION

INT INTERIOR

ILO IN LIEU OF

ISO ISOLATION

J ---------------------

JAN JANITOR

K ---------------------

KPD KEYPAD

KIT KITCHEN

KPL KICKPLATE

L ---------------------

LAM LAMINATE

LAV LAVATORY

LBR LUMBER

LBS POUND

LDG LANDING

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LIB LIBRARY

LIN LINEAR

LKR LOCKER

LOC LOCATION

LT LIGHT

LVDR LOUVER DOOR

LVR LOUVER

M ---------------------

MACH RM MACHINE ROOM

MATL MATERIAL

MAX MAXIMUM

MC MOISTURE CONTENT

MD METAL DECK

MECH MECHANICAL

MECH RM MECHANICAL ROOM

MEMB MEMBRANE

MF MILL FINISH

MFR MANUFACTURER

MID MIDDLE

MIL STD MILITARY STANDARD

MIN MINIMUM, MINUTE

MIRR MIRROR

MISC MISCELLANEOUS

MLDG MOLDING (MOULDING)

MO MASONRY OPENING

MOD MODIFY

MB MOISTURE BARRIER

MTG MOUNTING

MTL METAL

MVBL MOVABLE

MWP MEMBRANE WATERPROOFING

N ---------------------

N NORTH

NA NOT APPLICABLE

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NP NO PAINT

NRC NOISE REDUCTION COEFFICIENT

NTS NOT TO SCALE

O -------------------

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OFD OVERFLOW DRAIN

OFF OFFICE

OGL OBSCURE GLASS

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OPQ OPAQUE

OWSJ OPEN WEB STEEL JOIST

OPR OPERABLE

ORD OVERFLOW ROOF DRAIN

ORIG ORIGINAL

P --------------------

PA PUBLIC ADDRESS

PAR PARAPET

PAT PATTERN

PB PULL BOX

PBD PARTICLEBOARD

PCC PRECAST CONCRETE

PCF POUNDS PER CUBIC FOOT

PCT PERCENT

PERF PERFORATED

PERIM PERIMETER

PH PHASE

PIL PILASTER

PL PROPERTY LINE

PL GL PLATE GLASS

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLBG PLUMBING

PLG PILING

PLYWD PLYWOOD

PNL PANEL

PP PL PUSH/PULL PLATE

PR PAIR

PRCST PRECAST

PRKG PARKING

PS CONC PRESTRESSED CONCRETE

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PRESSURE TREATED

PTD PAPER TOWEL DISPENSER

PTDR PAPER TOWEL DISPENSER AND RECEPTACLE

PTN PARTITION

PWR POWER

Q --------------------

QT QUARRY TILE

QTY QUANTITY

R --------------------

RB RESILIENT BASE

RBM REINFORCED BRICK MASONRY

RBR RUBBER

RC REINFORCED CONCRETE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

RDG INS RIGID INSULATION, SOLID

REC RECESSED

REC ROOM RECREATION ROOM

REF REFERENCE

REM REMOVABLE

REP REPAIR

REPL REPLACE

REQ REQUIRE

REQD REQUIRED

RESIL RESILIENT

REST RESTROOM

RF RESILIENT FLOORING

RFG ROOFING

RH ROOF HATCH

RHR RIGHT HAND REVERSE

RL ROOF LEADER

RLG RAILING

RM ROOM

RO ROUGH OPENING

RSD ROLLING STEEL DOOR

RV ROOF VENT

RVL REVEAL

S --------------------

SB SPLASH BLOCK

SCHED SCHEDULE

SD SMOKE DETECTOR

SF SQUARE FOOT (FEET)

SFTWD SOFTWOOD

SGL SINGLE

SHT MTL FLASH SHEET METAL (FLASHING)

SHTHG SHEATHING

SHWR SHOWER

SHV SHELVING

SIM SIMILAR

SJ SCORED JOINT

SKLT SKYLIGHT

SLNT SEALANT

SMK SMOKE

SMLS SEAMLESS

SP EL SPOT ELEVATION

SPEC SPECIFICATION

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

SST STAINLESS STEEL

ST STAIRS

STD STANDARD

STL JST STEEL JOIST

STL RF DK STEEL ROOF DECK

STOR STORAGE

STR STRINGERS

STRB/HRN STROBE/HORN

SUB FL SUBFLOOR

SV SHEET VINYL

SW SIDEWALK

T --------------------

T TREAD

T/S TUB/SHOWER

TC TERRA COTTA

TD TRENCH DRAIN

TEL TELEPHONE

TEMP TEMPORARY

TER TERRAZZO

TFF TOP OF FINISH FLOOR

THK THICKNESS

TK BD TACKBOARD

TMPD GL TEMPERED GLASS

TN TRUE NORTH

TOF TOP OF FOOTING

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOPO TOPOGRAPHY

TOS TOP OF SLAB

TRANS TRANSOM

TRTD TREATED

TV TELEVISION

SEE OTHER DISCIPLINES FOR

ADDITIONAL ABREVIATIONS

NOTE: NOT ALL MAY BE USED

ARCHITECTURAL SYMBOLS

CHARACTER PROPORTIONS:

LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO

BETWEEN 3:5 AND 1:1 AND A STROKE-WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND

1:10, UTILIZING AN UPPER CASE 'X' FOR MEASUREMENT.

CHARACTER HEIGHT:

SEE LETTER AND NUMBER HEIGHT CHART BELOW

*EXCEPTION: CHARACTER HEIGHT SHALL BE 5/8" HIGH MINIMUM FOR BUILDING

DIRECTORIES.

PICTOGRAMS:

WHERE PICTOGRAMS ARE REQUIRED, THEY SHALL HAVE A 6" MINIMUM SIZE

MEASURED AT THE BORDER. WHERE TEXT DESCRIPTORS FOR PICTOGRAMS ARE

REQUIRED, THEY SHALL COMPLY WITH THE TACTILE CHARACTER PROVISIONS OF

RAISED CHARACTERS AND SYMBOLS, BRAILLE, AND LOCATION OF TACTILE

SIGNAGE PORTIONS BELOW.

FINISH AND CONTRAST:

THE CHARACTERS, SYMBOLS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL,

MATTE, OR OTHER NON-GLARE FINISH. CHARACTERS AND BRAILLE, AND LOCATION

OF TACTILE SIGNAGE PORTIONS BELOW. LIGHT BACKGROUND.

RAISED CHARACTERS AND SYMBOLS:

CHARACTERS AND SYMBOLS ON TACTILE SIGNS SHALL BE RAISED 1/32" MINIMUM.

RAISED CHARACTERS AND SYMBOLS SHALL BE IN UPPERCASE CHARACTERS.

RAISED CHARACTERS AND SYMBOLS SHALL BE 5/8" HIGH MINIMUM, AND 2"

MAXIMUM. RAISED CHARACTERS AND SYMBOLS SHALL BE ACCOMPANIED BY

BRAILLE IN ACCORDANCE WITH THE PROVISIONS OUTLINED BELOW.

BRAILLE:

BRAILLE SHALL BE SEPARATED 1/2" MINIMUM FROM THE CORRESPONDING RAISED

CHARACTERS OR SYMBOLS. BRAILLE PROVIDED IN ACCORDANCE WITH THE

REQUIREMENTS FOR ELEVATOR CONTROLS SHALL BE PLACED 3/16" MINIMUM BELOW

THE CORRESPONDING CHARACTERS OR SYMBOLS. BRAILLE SHALL BE GRADE II AND

SHALL CONFORM TO SPECIFICATION #800, NATIONAL LIBRARY SERVICE, LIBRARY OF

CONGRESS.

LOCATION OF TACTILE SIGNAGE:

TACTILE SIGNAGE SHALL BE LOCATED ALONGSIDE THE DOOR ON THE LATCH SIDE

AND SHALL BE MOUNTED AT 60" ABOVE THE ADJACENT FINISHED FLOOR TO THE

CENTERLINE OF THE SIGN. IN LOCATIONS HAVING DOUBLE DOORS, TACTILE SIGNS

SHALL BE MOUNTED TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS

NO WALL SPACE ON THE LATCH SIDE OF THE DOOR, INCLUDING DOUBLE LEAF

DOORS, SIGNS SHALL BE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE

ON THE LATCH SIDE OF THE DOOR, INCLUDING DOUBLE LEAF DOORS, SIGNS SHALL

BE PLACED ON THE NEAREST ADJACENT WALL.

GENERAL NOTES:

ANY ADDITIONAL TEXT REQUIRED DUE TO LOCAL ORDINANCES (FINES FOR

PARKING IN ACCESSIBLE SPACES, ETC.) SHALL COMPLY WITH THE SIGNAGE

REQUIREMENTS ABOVE.

ALL INTERIOR SIGNAGE WITHIN THE ASC SHALL CONFORM TO THE REQUIREMENTS

OF ADA 2010 AND ANY OTHER STATE OR LOCAL APPLICABLE CODES.

HEIGHT ABOVE FLOOR/ GROUND: MIN. CHARACTER HEIGHT:

GREATER THAN 80" (6'-8") AFF 3"

GREATER THAN 60" (5'-0") AFF BUT LESS THAN 80" (6'-8") AFF 2"

GREATER THAN 48" (4'-0") AFF BUT LESS THAN 60" (5'-0") AFF 1"

A FLOOR MOUNTED TOILET (CFCI)

GB42 42" GRAB BAR (BLOX FURNISHED & INSTALLED)

GB36 36" GRAB BAR (BLOX FURNISHED & INSTALLED)

GB18 18" GRAB BAR (VERTICAL) (BLOX FURNISHED &

INSTALLED)

E MIRROR (BLOX FURNISHED & INSTALLED)

F TOILET PAPER DISPENSER (OFCI)

G ROBE HOOK (CFCI)

H SOAP DISPENSER (OFCI)

H PAPER TOWEL DISPENSER (OFCI)

J SANITARY NAPKIN DISPOSAL (CFCI)

O BABY CHANGING TABLE (CFCI)

P WALL MOUNTED SINK (BLOX FURNISHED &

INSTALLED)

U SURFACE MTD TOILET SEAT COVER DISPENSER

(CFCI)

1. SEE SPECIFICATIONS FOR MANUFACTURERS INFORMATION ON ALL TOILET

ACCESSORIES.

2. ALL SOAP DISPENSERS, PAPER TOWEL DISPENSERS, TOILET PAPER

DISPENSERS & HAND SANITIZER DISPENSERS TO BE OWNER FURNISHED AND

CONTRACTOR INSTALLED. LOCATIONS SHOWN FOR FACILITY.

3. FOR ALL TOILET ROOMS, REFER TO BLOX VENDOR DRAWINGS FOR PARTITION

TYPES & DETAILS AND BLOCKING REQUIREMENTS FOR TOILET ACCESSORIES.

4. ALL TOILET LOCATIONS, WHETHER NOTED OR NOT, SHALL BE PROVIDED WITH

THE FOLLOWING UNLESS OTHERWISE NOTED:

a) ONE MIRROR

b) ONE TOILET PAPER DISPENSER

c) ONE ROBE HOOK - MOUNTED BEHIND STALL DOORS.

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Spinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

B

IM

/V

IS

N

O k la h o m a C it y P

A C

T R e n o v a ti o n /O k la h o m a C it y P

A C

T R e n o v a ti o n .r v t

/2

/2

:2

:3

P

M

BW LJ

635-19-101

GI101

635 - OKLAHOMA CITY, OK

SEPTEMBER 24, 2021

01-

ABBREVIATIONS & SYMBOLS 100% CONTRACT DOCUMENTS REMODEL B MOD OKLAHOMA VAMC

- OKLAHOMA CITY, OK

ACCESSIBLE SIGNAGE REQS

LETTER AND NUMBER HEIGHTS

TOILET ACCESSORY LEGEND

NOTES

A D

A

T O

H A

N D

L E

MIRROR SOAP DISPENSER PAPER

TOWEL

DISPENSER

TOILET PAPER

DISPENSER

TOILET

PAPER

HOLDER

SANITARY

NAPKIN

DISPOSAL

MIN

1' - 3"

LAVATORY

M

IN

INSULATE EXPOSED

PIPING WITH WHITE

PLASTIC PRE-FITTED

INSULATION

M A

X

MEASURE

TO BOTTOM

OF REFLECTIVE

SURFACE

D

IS

P E

N S

E R

M A

X O

P E

R A

B L E

D

IS

P E

N S

E R

M

A X

T O

O P

E R

A B

L E

M A

X

M

IN

M

IN

FIRE

EXTINGUISHERS

AND CABINETS

7-PEG

COAT RACK

2' - 0"

"MIN

8"

MIN

11"

KNEE AND TOE

CLEARANCES

E

E

SEALANT

PROVIDE ADA

COMPLIANT FAUCET

WITH WRIST BLADE

CONTROLS

M A

X

5" MAX 15" MAX

ACCESS HGT. D.F.

SPOUT LOCATION

M

IN

SPOUT

HEIGHT

STANDING AND

ACCESSIBLE DRINKING

FOUNTAINS

FRONT SIDE

PLAN

ALUM. SEMI-RECESSED CAB.

W/ FULL CLEAR ACRYLIC DOOR

10 LBS

ABC TYPE

BABY CHANGING

TABLE

M A

X

/2

ROBE

HOOK

M A

X

"FIRE EXTINGUISHER" IN

RED LETTERS

G

F

F

(ALT)H

J

C

N O O

P

P

M

IN9

MIN

11"

M

IN

8"

25" MAX

30x48

CLEAR

SPACE

U

M A

X

TOILET

SEAT COVER

DISPENSER

SIGNAGE

(12" BELOW CEILING)

2"

HANDRAIL

PER NFPA 10

PTD (OF/OI)

PUBLIC TLTS

ONLY

SEMI-

RECESSED

WASTE RECP.

S P

O U

T H

G T

S T

A N

D

IN

G H

E

IG

H T

D .F

A C

C E

S S

H

E

IG

H T

D .F

M A

X

NOTE: PROVIDE CANE

DETECTABLE APRON AT

THE STANDING HEIGHT

UNIT

MIN

3' - 6"

MAX

1' - 0"

WATER CLOSET

SIDE WALL

1 1/4" MIN., 2" MAX DIA.

GRAB BAR WITH 1 1/2"

GAP FROM WALL

WATER CLOSET

BACK WALL

TP DISPENSER

MOUNTING AREA

1' - 6"

T .O

G

.B

/2

4' - 6" MIN

MIN

1' - 0"

MIN

2' - 0"

FLUSH CONTROLS

ON OPEN SIDE

M

IN

GB42

GB36

A

A

3' - 4"

/2

GB18

U

CENTER ON

GRAB BAR END

NOTE: GRAB BARS

SHALL BE 33" - 36" TO

TOP OF BAR

MEASURE

TO BOTTOM

OF REFLECTIVE

SURFACE

3' - 0"

6"

6"

8"

MEN WOMEN

NO SMOKING

T

O F

IN

IS

H E

D F

L O

O R

F

IN

IS

H

E D

F L O

O R

T O

T O

F

IN

IS

H

E D

F L O

O R

PROPORTIONS OF THE INTERNATIONAL

SYMBOL OF ACCESSIBILITY

INTERIOR SIGNAGE

DOOR FRAME

LATCH SIDE OF

DOOR PANEL

TO TOP OF SIGN

GENERAL NOTES:

PROVIDE INTERIOR SIGNAGE FOR EVERY DOOR/ROOM UNLESS NOTED

OTHERWISE (REFER TO FINISH DRAWINGS).

ALL FINAL ROOM NAMES SHALL BE APPROVED BY ARCHITECT/OWNER PRIOR

TO SIGN FABRIACATION.

AT LOCATIONS WHERE THERE ISN'T AVAILABLE WALL SPACE TO INSTALL THE

INTERIOR SIGNAGE AS INDICATED, OBTAIN ARCHITECT'S INSTRUCTION PRIOR

TO INSTALLATION.

AT LOCATIONS WHERE THERE ISN'T AVAILABLE WALL SPACE, BUT AVAILABLE

WINDOW SPACE, ADHERE INTERIOR SIGNAGE WITH DOUBLE SIDED TAPE TO

PROVIDE A PERMANENT INSTALLATION. PROVIDE A BLANK PANEL OF THE

SAME COLOR, SIZE, AND MATERIAL FOR THE BACK SIDE OF THE SIGN TO BE

INSTALLED ON THE GLASS.

1.

2.

3.

4.

T-SHAPED TURNING SPACE

TURNING RADIUS

ø 5

5' - 0"

2' - 0" 3' - 0"

IF DOOR HAS BOTH

A CLOSER AND LATCH

OTHERWISE THIS = 0"

LATCH APPROACH, PUSH SIDE

Y= 4'-0" MIN IF DOOR HAS

A CLOSER, OTHERWISE Y = 3'-6"

FRONT APPROACH, PUSH SIDE

Y= 4'-6" MIN. IF DOOR HAS

A CLOSER, OTHERWISE

Y = 4'-0" MIN

Y= 4'-0" MIN IF DOOR HAS

BOTH A CLOSER AND LATCH

OTHERWISE Y = 3'-6"

HINGE APPROACH, PUSH SIDE

X= 3'-0" MIN. IF Y= 5'-0"

X= 3'-6" MIN. IF Y= 4'-6"

MIN

2' - 0"

Y M

IN

MIN

1' - 6"

Y X

MIN

2' - 0" Y 1' - 0" Y

1' - 10"

LATCH APPROACH, PULL SIDE FRONT APPROACH, PULL SIDE HINGE APPROACH, PULL SIDE

CHARACTER PROPORTIONS:

LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO

BETWEEN 3:5 AND 1:1 AND A STROKE-WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND

1:10, UTILIZING AN UPPER CASE 'X' FOR MEASUREMENT.

CHARACTER HEIGHT:

SEE LETTER AND NUMBER HEIGHT CHART BELOW

*EXCEPTION: CHARACTER HEIGHT SHALL BE 5/8" HIGH MINIMUM FOR BUILDING

DIRECTORIES.

PICTOGRAMS:

WHERE PICTOGRAMS ARE REQUIRED, THEY SHALL HAVE A 6" MINIMUM SIZE

MEASURED AT THE BORDER. WHERE TEXT DESCRIPTORS FOR PICTOGRAMS ARE

REQUIRED, THEY SHALL COMPLY WITH THE TACTILE CHARACTER PROVISIONS OF

RAISED CHARACTERS AND SYMBOLS, BRAILLE, AND LOCATION OF TACTILE

SIGNAGE PORTIONS BELOW.

FINISH AND CONTRAST:

THE CHARACTERS, SYMBOLS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL,

MATTE, OR OTHER NON-GLARE FINISH. CHARACTERS AND BRAILLE, AND LOCATION

OF TACTILE SIGNAGE PORTIONS BELOW. LIGHT BACKGROUND.

RAISED CHARACTERS AND SYMBOLS:

CHARACTERS AND SYMBOLS ON TACTILE SIGNS SHALL BE RAISED 1/32" MINIMUM.

RAISED CHARACTERS AND SYMBOLS SHALL BE IN UPPERCASE CHARACTERS.

RAISED CHARACTERS AND SYMBOLS SHALL BE 5/8" HIGH MINIMUM, AND 2"

MAXIMUM. RAISED CHARACTERS AND SYMBOLS SHALL BE ACCOMPANIED BY

BRAILLE IN ACCORDANCE WITH THE PROVISIONS OUTLINED BELOW.

BRAILLE:

BRAILLE SHALL BE SEPARATED 1/2" MINIMUM FROM THE CORRESPONDING RAISED

CHARACTERS OR SYMBOLS. BRAILLE PROVIDED IN ACCORDANCE WITH THE

REQUIREMENTS FOR ELEVATOR CONTROLS SHALL BE PLACED 3/16" MINIMUM BELOW

THE CORRESPONDING CHARACTERS OR SYMBOLS. BRAILLE SHALL BE GRADE II AND

SHALL CONFORM TO SPECIFICATION #800, NATIONAL LIBRARY SERVICE, LIBRARY OF

CONGRESS.

LOCATION OF TACTILE SIGNAGE:

TACTILE SIGNAGE SHALL BE LOCATED ALONGSIDE THE DOOR ON THE LATCH SIDE

AND SHALL BE MOUNTED AT 60" ABOVE THE ADJACENT FINISHED FLOOR TO THE

CENTERLINE OF THE SIGN. IN LOCATIONS HAVING DOUBLE DOORS, TACTILE SIGNS

SHALL BE MOUNTED TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS

NO WALL SPACE ON THE LATCH SIDE OF THE DOOR, INCLUDING DOUBLE LEAF

DOORS, SIGNS SHALL BE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE

ON THE LATCH SIDE OF THE DOOR, INCLUDING DOUBLE LEAF DOORS, SIGNS SHALL

BE PLACED ON THE NEAREST ADJACENT WALL.

GENERAL NOTES:

ANY ADDITIONAL TEXT REQUIRED DUE TO LOCAL ORDINANCES (FINES FOR

PARKING IN ACCESSIBLE SPACES, ETC.) SHALL COMPLY WITH THE SIGNAGE

REQUIREMENTS ABOVE.

ALL INTERIOR SIGNAGE WITHIN THE ASC SHALL CONFORM TO THE REQUIREMENTS

OF ADA 2010 AND ANY OTHER STATE OR LOCAL APPLICABLE CODES.

HEIGHT ABOVE FLOOR/ GROUND: MIN. CHARACTER HEIGHT:

GREATER THAN 80" (6'-8") AFF 3"

GREATER THAN 60" (5'-0") AFF BUT LESS THAN 80" (6'-8") AFF 2"

GREATER THAN 48" (4'-0") AFF BUT LESS THAN 60" (5'-0") AFF 1"

A FLOOR MOUNTED TOILET (CFCI)

GB42 42" GRAB BAR (BLOX FURNISHED & INSTALLED)

GB36 36" GRAB BAR (BLOX FURNISHED & INSTALLED)

GB18 18" GRAB BAR (VERTICAL) (BLOX FURNISHED &

INSTALLED)

E MIRROR (BLOX FURNISHED & INSTALLED)

F TOILET PAPER DISPENSER (OFCI)

G ROBE HOOK (CFCI)

H SOAP DISPENSER (OFCI)

H PAPER TOWEL DISPENSER (OFCI)

J SANITARY NAPKIN DISPOSAL (CFCI)

O BABY CHANGING TABLE (CFCI)

P WALL MOUNTED SINK (BLOX FURNISHED &

INSTALLED)

U SURFACE MTD TOILET SEAT COVER DISPENSER

(CFCI)

1. SEE SPECIFICATIONS FOR MANUFACTURERS INFORMATION ON ALL TOILET

ACCESSORIES.

2. ALL SOAP DISPENSERS, PAPER TOWEL DISPENSERS, TOILET PAPER

DISPENSERS & HAND SANITIZER DISPENSERS TO BE OWNER FURNISHED AND

CONTRACTOR INSTALLED. LOCATIONS SHOWN FOR FACILITY.

3. FOR ALL TOILET ROOMS, REFER TO BLOX VENDOR DRAWINGS FOR PARTITION

TYPES & DETAILS AND BLOCKING REQUIREMENTS FOR TOILET ACCESSORIES.

4. ALL TOILET LOCATIONS, WHETHER NOTED OR NOT, SHALL BE PROVIDED WITH

THE FOLLOWING UNLESS OTHERWISE NOTED:

a) ONE MIRROR

b) ONE TOILET PAPER DISPENSER

c) ONE ROBE HOOK - MOUNTED BEHIND STALL DOORS.

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Spinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

B

IM

/V

IS

N

O k la h o m a C it y P

A C

T R e n o v a ti o n /O k la h o m a C it y P

A C

T R e n o v a ti o n .r v t

/2

/2

:2

:5

P

M

BW LJ

635-19-101

GI102

635 - OKLAHOMA CITY, OK

SEPTEMBER 24, 2021

01-

ADA INFORMATION 100% CONTRACT DOCUMENTS REMODEL B MOD OKLAHOMA VAMC

NOTE: THESE DRAWINGS DO NOT

INCLUDE IBC BUILDING CODE

INFORMATION

CODE SUMMARY – BUILDING 1 GROUND FLOOR B MODULE

1. DRAWING PURPOSE : NFPA CODE COMPLIANCE

2. FACILITY REVIEWED FOR COMPLIANCE WITH THE FOLLOWING CODES:

a. 2018 NFPA 101 LIFE SAFETY CODE

1. CHAPTER 4 – GENERAL

2. CHAPTER 6 - CLASSIFICATION OF OCCUPANCY AND HAZARD CONTENTS

3. CHAPTER 7 - MEANS OF EGRESS

4. CHAPTER 21 - EXISTING AMBULATORY OCCUPANCY

3. OWNER:

OKLAHOMA CITY VA HEALTH CARE SYSTEM

921 NE 13TH STREET

OKLAHOMA CITY, OK 73104

PH (405) 456-1000

4. DATE DEVELOPED: 7/29/2021

5. ARCHITECT:

ROMANYK CONSULTING

3308 PRESTON ROAD

SUITE 350-164

PLANO, TEXAS

6. ARCHITECT SEAL: SEE STAMP IN TITLEBLOCK

7. FIRE SERVICE: OKLAHOMA CITY FIRE DEPARTMENT

8. INSPECTION: TJC; CITY OF OKLAHOMA CITY

9. OCCUPANCY GROUP TYPE:

a. OCCUPANCY 1/ BUILDING 1/ GROUND FLOOR: AMBULATORY HEALTHCARE OCCUPANCY

10. CONSTRUCTION TYPE:

CONSTRUCTION TYPE II - NFPA TYPE 222, (TABLE 19.1.6.1)

11. BUILDING 1 - OCCUPANCY 1 GROSS FLOOR AREAS:

GROUND FLOOR AREA ACTUAL: 63,736 SF (TOTAL FLOOR)

6,330 SF (AREA OF WORK)

12. HEIGHT & AREA LIMITATIONS:

ALLOWABLE AREA: UNLIMITED

AMBULATORY HEALTH CARE OCCUPANCY:

ALLOWABLE HEIGHT/ 4 OR MORE STORIES

ACTUAL HEIGHT/STORIES 10 OCCUPIABLE STORIES

13. MINIMUM CONSTRUCTION REQUIREMENTS (A.8.2.1.2):

CONSTRUCTION TYPE II (222)

AMBULATORY

HEALTHCARE

OCCUPANCY

BEARING WALLS:

A. EXTERIOR 2 HR

B. INTERIOR 2 HR

C. INT/EXT (ROOF ONLY) 1 HR

NON-BEARING WALLS:

A. EXTERIOR 0 HR

B. INTERIOR NON-COMBUSTIBLE

COLUMNS:

A. SUPPORT FLOORS 2 HR

B. SUPPORT ROOF ONLY 1 HR

BEAMS/GIRDER/TRUSSES:

A. EXTERIOR: 2 HR

B. INTERIOR: 1 HR

FLOOR CONSTRUCTION: 2 HR

ROOF CONSTRUCTION: 1 HR

14. ACTIVE FIRE SAFETY FEATURES:

a. AUTOMATIC SUPPRESSION SYSTEMS:

• SPRINKLER SYSTEM (FULLY SPRINKLED)

• AUTOMATIC AIR-HANDLING SHUT-DOWN

b. FIRE ALARM SYSTEM - HONEYWELL, ADDRESSABLE, AUTO DIAL-UP

c. GENERATOR POWERED EMERGENCY LIGHTING, GENERATOR POWERED

d. EXIT LIGHTING.

e. PORTABLE EXTINGUISHERS

f. SMOKE DETECTORS WILL BE IN MECHANICAL AND ELECTRICAL ROOMS, STORAGE ROOMS, DATA ROOMS, CORRIDORS, SMOKE DOORS AND OTHER AREAS AS REQUIRED

15. WATER SUPPLY: CITY OF OKLAHOMA CITY

16. SPRINKLERS: FULLY SPRINKLERED

17. TOTAL OCCUPANTS

TABLE 7.3.1.2 OCCUPANT LOAD FACTOR

USE (FT2 /PERSON)

AMBULATORY HEALTHCARE USE

INPATIENT TREATMENT DEPARTMENTS 240

SLEEPING DEPARTMENTS 120

AMBULATORY HEALTH CARE 150

OCCUPANT LOAD = FLOOR AREA/OCCUPANT LOAD FACTOR (TABLE 7.3.1.2)

(AREA OF WORK): 7,690/150 = 52 occupants

18. EXIT WIDTH: TABLE 7.3.3.1 CAPACITY FACTORS

EXIT WIDTH STAIRS: 52 OCCUPANTS X.3 INCHES = 15.6" (SCOPE OF WORK)

EXIT WIDTH LEVEL COMPONENTS: 52 OCCUPANTS X .2 INCHES = 10.4" (SCOPE OF WORK)

19. MEANS OF EGRESS: TWO MEANS OF EGRESS, AS A MINIMUM REQUIRED (4.5.3.1).

ACTUAL MEANS OF EGRESS (SCOPE OF WORK): 3 MEANS OF EGRESS

20. DOOR OPENINGS IN MEANS OF EGRESS: SHALL BE NO LESS THAN 32"

IN CLEAR WIDTH (7.2.1.2.3.2). DOOR OPENINGS IN PROJECT ARE 36".

21. DEAD END CORRIDORS: DEAD END CORRIDORS SHALL NOT EXCEED 30 FEET.

ACTUAL PROJECT DEAD END CORRIDOR (SCOPE OF WORK) = 6 FEET.

22. TABLE 7.3.3.1 CAPACITY FACTORS: STAIRWAY (WIDTH/PERSON), HEALTHCARE,

SPRINKLERED = .2 INCHES (LEVEL COMPONENTS AND RAMPS)

23. CORRIDOR WIDTH: AISLES, CORRIDORS, AND RAMPS IN ADJUNCT AREAS NOT INTENDED FOR THE HOUSING, TREATMENT, OR USE OF INPATIENTS SHALL BE NOT LESS THAN

44 INCHES IN CLEAR AND UNOBSTRUCTED WIDTH (19.2.3.4).

ACTUAL CORRIDOR WIDTH (SCOPE OF WORK): 72 INCHES (MIN.)

24. NUMBER OF EXITS FOR EACH STORY: NOT LESS THAN TWO EXITS SHALL BE PROVIDED ON EACH STORY 19.2.4.2). ACTUAL PROJECT EXITS = 6.

25. TRAVEL DISTANCE TO EXITS= THE TRAVEL DISTANCE BETWEEN ANY POINT IN A ROOM AND AN EXIT SHALL NOT EXCEED 150 FEET(19.2.6.2.1). ACTUAL TRAVEL DISTANCE

100.5 FEET.(GROUND FLOOR)

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Spinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

B

IM

/V

IS

N

O k la h o m a C it y P

A C

T R e n o v a ti o n /O k la h o m a C it y P

A C

T R e n o v a ti o n .r v t

/2

/2

:2

:0

P

M

BW LJ

635-19-101

GI103

635 - OKLAHOMA CITY, OK

SEPTEMBER 24, 2021

01-

BUILDING CODE DATA 100% CONTRACT DOCUMENTS REMODEL B MOD OKLAHOMA VAMC

LIFE SAFETY NOTES

FE

FEC

LIFE SAFETY LEGEND

PLAN LEGEND

1. THIS PLAN IS FOR LIFE SAFETY INFORMATION ONLY.

2. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13

AND IS

3. PROTECTED WITH A SUPERVISED AUTOMATIC SMOKE DETECTION

SYSTEM.

4. WALL TYPES ARE DETAILED ON G002 AND INDICATED ON THE

DIMENSIONED FLOOR PLAN ON A102.

5. REFER TO THIS DRAWING FOR MEANS OF EGRESS

6. REFER TO THIS DRAWING FOR DOOR CAPACITIES.

7. FINAL LOCATION OF FAAP PANEL TO BE COORDINATED WITH FIRE

MARSHAL.

FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER

FDC

F

L

L

D

MHO

FACP

FAAP

FIRE DEPARTMENT CONNECTION

EXIT

ILLUMINATED EXIT SIGN

FIRE ALARM - MANUAL PULL STATION

FIRE ALARM - STROBE / CHIME

FIRE ALARM - STROBE

SMOKE DETECTOR

MAGNETIC HOLD OPEN

FIRE ALARM CONTROL PANEL

FIRE ALARM ANUNCIATOR PANEL

EXTERIOR EMERGENCY LIGHTING

DD

EE

FF

GG

HH

II

JJ

K

123 SF

EXAM/CONSULT ROOM

GF124D

125 SF

EXAM/CONSULT ROOM

GF124E

118 SF

EXAM/CONSULT ROOM

GF113

123 SF

EXAM/CONSULT ROOM

GF112

136 SF

EXAM/CONSULT ROOM

GF124B

29 SF

HEIGHT/WEIGHT

ALCOVE

GF105

75 SF

BLOOD SPECIMEN

COLLECTION

GF103E

73 SF

BLOOD SPECIMEN

COLLECTION

GF103F

76 SF

BLOOD SPECIMEN

COLLECTION

GF103D

75 SF

BLOOD SPECIMEN

COLLECTION

GF103C

57 SF

TOILET SPECIMEN

COLLECTION

GF103B

211 SF

LAB

GF103

55 SF

TOILET SPECIMEN

COLLECTION

GF103A

75 SF

BLOOD SPECIMEN

COLLECTION

GF103K

74 SF

BLOOD SPECIMEN

COLLECTION

GF103J

73 SF

BLOOD SPECIMEN

COLLECTION

GF103H

70 SF

BLOOD SPECIMEN

COLLECTION

GF103G

62 SF

PATIENT TLT.

GF117

51 SF

STAFF LOCKER

GF125

64 SF

STAFF TLT.

GF116

183 SF

LAB 2 RECEPTION

WORKSTATIONS

GF124H

72 SF

CLEAN UTILITY

GF124J

111 SF

LOGISTICS STORAGE

GF119

117 SF

TELECOMMUNICATIONS

ROOM

GF118

32 SF

PATIENT CHECK-IN

GF124I

846 SF

WAITING

GF124

125 SF

EXAM/CONSULT ROOM

GF124C

121 SF

CONSULT ROOM

GF114

717 SF

TEAM WORK AREA

GF124A

22 SF

ALCOVE RESUS

GF124L

24 SF

ALCOVE WHEELCHAIR

GF124K

10 SF

BLOOD SPECIMEN

ALCOVE

GF103I

GRAY AREA NOT IN PROJECT

SCOPE

27 SF

ELECT.

GF106

118 SF

CONSULT ROOM

GF115

112 SF

MED. ROOM

GF124F

803 SF

PATIENT CORRIDOR

CGF 5

308 SF

PATIENT CORRIDOR

CGF 4

AE102

EXISTING

STAIR #7

TRAVEL DISTANCE: 65' - 0"

TRAVEL DISTANCE: 100' - 6"

63 SF

PATIENT TLT.

GF102

EXISTING BUILDING #1 - OCCUPANCY #1 - GROUND FLOOR =

63,736 SF

OCCUPANCY TYPE - AMBULATORY HEALTHCARE

TYPE II (222) CONSTRUCTION

TOTAL OCCUPANTS 425

FULLY SPRINKLERED

COMPLIANCE NOTE

PER 7.5.1.6

EXIT ACCESS FROM ROOMS OR SPACES SHALL BE

PERMITTED TO BE THROUGH

ADJOINING OR INTERVENING ROOMS OR AREAS,

PROVIDED THAT SUCH ROOMS OR AREAS ARE

ACCESSORY TO THE AREA SERVED. FOYERS, LOBBIES,

AND RECEPTION ROOMS. CONSTRUCTED AS

REQUIRED FOR CORRIDORS SHALL NOT BE

CONSTRUED AS INTERVENING ROOMS.

CONTROLLED

ACCESS

TRAVEL

PATH

STARTING

LOCATION

TD = XX

TRAVEL DISTANCE

NO. OF OCC./

NO. OF EXITS

ACTUAL

EXIT

WIDTH

OCC.

LOAD

FACTOR

LIFE SAFETY SYMBOLS

10/1

2"

34"

1:50

NO. OCC. EXITING

(SMALLER ROOMS)

MAXIMUM OCCUPANCY

AREA

REQ'D. EXIT WIDTH

NO. OF OCC. EXITING

LEGEND

BUILDING & LIFE SAFETY REQUIREMENTS

DESCRIPTION

NEW

PARTITION KEY

NFPA

101-2015

OPENINGS DAMPERS

RATING RFRNC. TYPE RFRNC.

BUILDING SEPARATION:

FIRE BARRIER

(FIRE WALL IN IBC)

2 HR 90 MIN

OCCUPANCY/AREA SEPARATION

FIRE BARRIER

90 MIN

HORIZONTAL EXIT (& REFUGE AREA)

FIRE BARRIER

2 HR 90 MIN

VERT. OPG. (EXIT ENCLSR/SHAFT)

FIRE BARRIER

(2 HR = 4 OR MORE STORIES)

(1 HR = LESS THAN 4 STORIES)1 HR

2 HR

60 MIN

90 MIN

HAZ./INCIDENTAL USE

FIRE BARRIER

45 MIN

HAZ./INCIDENTAL USE

SMOKE PARTITIONS (SPRINKLERED)

NR

SELF OR AUTO

CLOSING

SUBDIVIDING SPACES

SMOKE BARRIER (I-2 OCCUPANCY)

20 MIN

1/2

HR

1 HR

SUITE SEPARATION

SMOKE PARTITION

EXIT ACCESS CORRIDORS (I-2)

SMOKE PARTITIONS (SPRINKLERED)

NR

EXIT ACCESS CORRIDORS (B & AHC)

NON-RATED PARTITIONS

NR

VERT. OPG. (SHAFT)

FIRE BARRIER

60 MIN

[D]

1 HR

2 HR

60 MIN

90 MIN

EXIT PASSAGEWAY (HORIZ.)

FIRE BARRIER

8.7

NFPA 6.1.14.4.1

18.1.3.5.1 19.1.3.5.1

NFPA 7.2.A.3.1 (1)

NFPA 18.1.3.8/

19.1.3.8 18.2.2.5/19.2.25 7.1.3.2.1

NFPA 19.3.1.1

NFPA 8.6.2

8.6.5

NFPA 18.3.2.1.2

NFPA 8.4.1.1

19.3.2.1

NFPA 8.4.2 (3)

18.3.2.1.3 19.3.2.1.2

NFPA 8.5.2

18.3.7.3 19.3.7.3

NFPA 8.4.2

18.2.5.7.1.4 19.2.5.7.1.1

NFPA 8.4.2

18.3.6.2 19.3.6.2

21.3.6 39.3.6

NFPA 19.3.1.1

19.2.2.7 8.6.2 8.6.5(3) & 2

NFPA 7.2.6

19.2.2.7 18.2.2.7

NFPA 221

8.2.1.3

EXIST SOL.

CORE WD.

NFPA 7.2.1.4.1

7.2.4.3.7 8.3.4 18.2.2.5.3,4,5,6,7 19.2.2.5,3,4

8.3.4.2 TBL

18.4.4.7.2.2

7.1.3.2.9 (9)

NFPA 8.3.4.2 TBL

19.3.2.1.3,5

NFPA 8.3.4.2 TBL

8.5.4 18.3.7.8

NFPA 8.3.4.2 TBL

8.3.4.2 TBL

8.3.4.2 TBL

NFPA 8.3.4.2 TBL

8.3.4.2 8.4.3 19.3.2.1.4,3,5

8.4.3

8.4.3 18.3.6.4.1 19.3.6.4.1

N/A

FIRE

90 MIN

FIRE

90 MIN

VARIES

SMOKE

90 MIN

VARIES

VARIES

NONE

N/A

NOT

ALLOWED

NFPA 90

8.3.5.7 9.2.1

NFPA 8.3.5.7

9.2.1 7.2.4.3.5

N/A

8.5.5.2 18.3.7.3(2) 19.3.7.3(2)

8.6.4.5

N/A

N/A

8.4.4.1 8.4.6.2

8.4.4.1 8.4.6.2

8.4.4.1 8.4.6.2 18.3.6.4.1

N/A

WALL

RATING

RATED UL

ASSEMBLIES

2 HR

1 HR

1 HR

NR-

RESIST

SMK

NR

NR-

RESIST

SMK

NR

8.3

UL U412

UL U419

UL U412

UL U419

UL U412

UL U419

UL U412

UL U419

UL U415 (A)

UL U412

UL U419

UL U415 (A)

UL U412

UL U419

UL U412

UL U419

UL U415 (A)

NR

SELF OR AUTO

CLOSING

FIRE

90 MIN

FIRE

90 MIN

NOT

ALLOWED

UNLESS

SERVING

STAIR ONLY

NFPA 90

8.3.5.7 9.2.1

AREA WITHIN SCOPE OF WORK = 7,690 SQUARE FEET

AREA NOT IN CONTRACT

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Spinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

B

IM

/V

IS

N

O k la h o m a C it y P

A C

T R e n o v a ti o n /O k la h o m a C it y P

A C

T R e n o v a ti o n .r v t

/2

/2

:2

:2

P

M

BW LJ

635-19-101

GI104

635 - OKLAHOMA CITY, OK

SEPTEMBER 24, 2021

01-

LIFE SAFETY PLAN 100% CONTRACT DOCUMENTS REMODEL B MOD OKLAHOMA VAMC

- OKLAHOMA CITY, OK

1" = 10'-0"

GROUND LEVEL - LIFE SAFETY PLAN

GENERAL NOTES

1. THE PURPOSE OF THE CONSTRUCTION PHASING

NOTES AND DRAWINGS IS TO PROVIDE THE

GENERAL CONTRACTOR (GC) WITH GUIDANCE FOR

THE CONSTRUCTION SCHEDULE.

2. THE GC SHALL COORDINATE WITH THE

CONTRACTING OFFICER REPRESENTATIVE (COR) TO

DEVELOP A CRITICAL PATH METHOD (CPM)

SCHEDULE, SEQUENCING, COMPLETION DATES FOR

RENOVATION AND NEW CONSTRUCTION FOR THE

PROJECT.

3. THE MEDICAL CENTER MUST REMAIN IN FULL

OPERATION DURING CONSTRUCTION WITH MINIMAL

INTERRUPTION DUE TO ALL CONSTRUCTION

ACTIVITIES FOR THE PROJECT, INCLUDING NOISE,

DUST, VIBRATION, ETC., CREATED BY

CONSTRUCTION ACTIVITIES RELATED TO THIS

PROJECT.

4. THE GC’S SCHEDULES SHOULD INCLUDE BUT IS NOT

LIMITED TO THE FOLLOWING:

• ALL CONSTRUCTION-ACTIVITY-RELATED ISSUES

WHICH MAY AFFECT THE CONTINUAL

OPERATIONS OF THE MEDICAL CENTER.

• SCHEDULES FOR SHUTTING DOWN EXISTING

SYSTEMS OR ACCESS FOR TIE-INS AND/OR

REPLACEMENT.

• SCHEDULES FOR AFTER-HOURS CONSTRUCTION

ACTIVITIES.

5. PROVIDE TEMPORARY CHAINLINK CONSTRUCTION

FENCING WITH GATES AND CONSTRUCTION

BARRIERS AS REQUIRED TO SEPARATE

CONSTRUCTION ACTIVITIES FROM PUBLIC AREAS

AND AREAS REQUIRING ACCESS DURING

CONSTRUCTION. FENCING AND BARRIERS SHOULD

BE RELOCATED AS REQUIRED AFTER EACH PORTION

OF WORK IS COMPLETED TO ACCOMMODATE

ACCESS TO EXISTING FACILITIES AS CONSTRUCTION

PROGRESSES.

6. IF MEDICAL CENTER ACCESS PATHWAYS IDENTIFIED

ON THE PHASING PLANS ARE REQUIRED TO BE

BLOCKED TEMPORARILY TO ACCOMMODATE

CONSTRUCTION, COORDINATE ALTERNATE

PATHWAYS WITH THE COR AND PROVIDE

TEMPORARY SIGNAGE AND TEMPORARY

PROTECTIVE BARRIERS TO CREATE ALTERNATE

PATHWAYS AS REQUIRED. VERTICAL EXPANSION OF

THE EXISTING EAST AND WEST STAIRS MAY NEED TO

OCCUR AFTER-HOURS, SO THEY REMAIN IN SERVICE

DURING CONSTRUCTION. REFER TO THE PHASING

DIAGRAMS FOR ADDITIONAL NOTES. COORDINATE

AND SCHEDULE ANY DOWNTIME FOR THESE ROUTES

WITH THE COR.

7. THE GC SHALL SEEK FINAL APPROVAL OF THE

LOCATION OF CONSTRUCTION FENCING,

TEMPORARY CONSTRUCTION AND INFECTION

CONTROL BARRIERS, CONTRACTOR SITE ACCESS

AND DEBRIS AND MATERIAL HAUL ROUTES WITH THE

COR.

8. MAINTAIN ACCESS TO ALL EXISTING BUILDINGS,

UTILITIES AND FACILITIES WITHIN THE

CONSTRUCTION LIMITS TO ACCESS EQUIPMENT AND

TO PROVIDE SERVICE OR MAINTENANCE OF

EXISTING FACILITIES AND EQUIPMENT SERVING THE

MEDICAL CENTER.

9. COORDINATE UTILITY SHUT DOWNS OR ANY

CONSTRUCTION ACTIVITIES WHICH MAY

POTENTIALLY AFFECT THE EXISTING OPERATIONS

OF THE MEDICAL CENTER WITH THE COR. MAINTAIN

UNINTERRUPTED OPERATION OF THE EXISTING

FACILITIES, AND MINIMIZE DISRUPTIONS TO THE

MEDICAL CENTER FOR ALL SWITCH-OVER OF

UTILITIES. SCHEDULE THESE EVENTS AFTER-HOURS

OR AS APPROVED BY THE COR.

10. THE GC HAS RESPONSIBILITY IN DETERMINING THE

CORRECT PHASING TO MATCH THE REQUIREMENTS

OF THE CONSTRUCTION CONTRACT AS WELL AS THE

ACTUAL LOCATIONS AND THE METHODS THROUGH

WHICH TO CONSTRUCTION THE ICRA-COMPLIANT

CONSTRUCTION BARRIERS.

11. THE GC SHALL COORDINATE WITH THE COR TO

LOCATE THE SAFETY SIGN AND CONSTRUCTION

SIGN.

12. THE GENERAL CONTRATOR SHALL PROVIDE

ISOLATION BARRIERS.COMPLETE ALL CRITICAL

BARRIERS BEFORE CONSTRUCTION WORK BEGINS.

13. MAINTAIN ALL FIRE BARRIERS AND DUST

PARTITIONS AS REQUIRED TO PROVIDE A DUST-FREE

AND CLEAN ENVIRONMENT BETWEEN RENOVATED

AREAS WITHIN THE HOSPITAL AND AREAS ADJACENT

TO RENOVATED AND NEW CONSTRUCITON.

14. MAINTAIN INSULATED AND WATERTIGHT EXTERIOR

ENCLOSURE FOR EXISTING FACILITY AT ALL TIMES.

WORK REQUIRED TO REMOVE THE EXISTING

PARAPET, ROOFING, MASONRY, ETC. TO

ACCOMMODATE THE VERTICAL EXPANSION SHALL BE

PERFORMED IN PHASES TO PROTECT THE

ENCLOSURE.

15. ISOLATE HVAC SYSTEM WHERE WORK IS

PERFORMED TO PREVENT CONTAMINATION OF DUCT

SYSTEM.

16. ALL PERSONNEL ENTERING RENOVATION AREAS

WITHIN OCCUPIED FLOORS OF THE MEDICAL CENTER

SHALL WEAR SHOE COVERS, AND THESE MUST BE

CHANGED EACH TIME THE WORKER EXITS THE

WORK AREA. PROVIDE ADHESIVE WALK-OFF MATS

AT ENTRANCES TO THESE WORK AREAS. IF THERE

IS AN ANTEROOM, A MAT SHOULD BE WITHIN THIS

AREA. REPLACE MATS DAILY OR WHEN THEY NO

LONGER ARE ABLE TO CONTAIN DUST AND DIRT.

WET MOP AND/OR VACUUM WORK AREA WITH HEPA

FILTERED VACUUM BEFORE LEAVING WORK AREAS.

CONTAIN CONSTRUCTION WASTE IN TIGHTLY

COVERED CONTAINERS BEFORE TRANSPORTING.

REMOVE HVAC ISOLATION FROM SYSTEM IN AREAS

WHERE WORK IS BEING PERFORMED. REMOVE

BARRIER MATERIALS CAREFULLY TO MINIMIZE THE

SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH

CONSTRUCTION. DO NOT REMOVE BARRIERS FROM

WORK AREA UNTIL COMPLETED PROJECT IS

THOROUGHLY CLEANED.

17. REFER TO SPECIFICATIONS SECTION 01 00 00

GENERAL REQUIREMENTS.

DD

EE

FF

GG

HH

II

JJ

K

123 SF

EXAM/CONSULT ROOM

GF124D

125 SF

EXAM/CONSULT ROOM

GF124E

118 SF

EXAM/CONSULT ROOM

GF113

123 SF

EXAM/CONSULT ROOM

GF112

136 SF

EXAM/CONSULT ROOM

GF124B

29 SF

HEIGHT/WEIGHT

ALCOVE

GF105

75 SF

BLOOD SPECIMEN

COLLECTION

GF103E

73 SF

BLOOD SPECIMEN

COLLECTION

GF103F

76 SF

BLOOD SPECIMEN

COLLECTION

GF103D

75 SF

BLOOD SPECIMEN

COLLECTION

GF103C

57 SF

TOILET SPECIMEN

COLLECTION

GF103B

211 SF

LAB

GF103

55 SF

TOILET SPECIMEN

COLLECTION

GF103A

75 SF

BLOOD SPECIMEN

COLLECTION

GF103K

74 SF

BLOOD SPECIMEN

COLLECTION

GF103J

73 SF

BLOOD SPECIMEN

COLLECTION

GF103H

70 SF

BLOOD SPECIMEN

COLLECTION

GF103G

62 SF

PATIENT TLT.

GF117

51 SF

STAFF LOCKER

GF125

64 SF

STAFF TLT.

GF116

183 SF

LAB 2 RECEPTION

WORKSTATIONS

GF124H

72 SF

CLEAN UTILITY

GF124J

111 SF

LOGISTICS STORAGE

GF119

117 SF

TELECOMMUNICATIONS

ROOM

GF118

32 SF

PATIENT CHECK-IN

GF124I

846 SF

WAITING

GF124

125 SF

EXAM/CONSULT ROOM

GF124C

121 SF

CONSULT ROOM

GF114

717 SF

TEAM WORK AREA

GF124A

22 SF

ALCOVE RESUS

GF124L

24 SF

ALCOVE WHEELCHAIR

GF124K

10 SF

BLOOD SPECIMEN

ALCOVE

GF103I

GRAY AREA NOT IN PROJECT

SCOPE

27 SF

ELECT.

GF106

118 SF

CONSULT ROOM

GF115

112 SF

MED. ROOM

GF124F

803 SF

PATIENT CORRIDOR

CGF 5

308 SF

PATIENT CORRIDOR

CGF 4

TRAVEL DISTANCE: 65' - 0"

TRAVEL DISTANCE: 100' - 6"

63 SF

PATIENT TLT.

GF102

CONTROLLED

ACCESS

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Spinklered

Office of Construction and Facilities Management

FULLY SPRINKLERED

B

IM

/V

IS

N

O k la h o m a C it y P

A C

T R e n o v a ti o n /O k la h o m a C it y P

A C

T R e n o v a ti o n .r v t

/2

/2

:2

:4

P

M

BW LJ

635-19-101

GI105

635 - OKLAHOMA CITY, OK

SEPTEMBER 24, 2021

01-

GROUND FLOOR PHASING PLAN 100% CONTRACT DOCUMENTS REMODEL B MOD OKLAHOMA VAMC

- OKLAHOMA CITY, OK

1" = 10'-0"

GROUND LEVEL -PHASING PLAN

MATERIAL LEGEND

KEY NOTES

BLACK MASTIC UNDER 12" x 12" FLOOR TILE

ASSUMED RESIDUAL BLACK MASTIC UNDER CARPET &

WOOD LAMINATE

TAN DUCT MASTIC THROUGHOUT PLENUM

1 2 3 4 5 6 7

H

I

J

K

G ra p h ic S ca le

/2

0"

G ra p h ic S ca le

/3 2"

0"

' G ra p h ic S ca le

/1 6"

0"

' G ra p h ic

S ca le

/8

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

/8

0"

' G ra p h ic

S ca le

/2

0"

G ra p h ic S ca le

/4

0"

G ra p h ic S ca le

0"

Romanyk Consulting Focusing on what matters

NORTH

KEY PLAN

NTS

NORTH

E

A

B

F

D

G

HW

C22

5 18

MOD B RENOVATION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1

Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

Spinklered

Office of Construction and Facilities Management

NORTH

FULLY SPRINKLERED

B

IM

/V

IS

N

O k la h o m a C it y P

A C

T R e n o v a ti o n /O k la h o m a C it y P

A C

T R e n o v a ti o n .r v t

/2

/2

:2

:0

P

M

GAG RCV

635-19-101

HA101

635 - OKLAHOMA CITY, OK

SEPTEMBER 24, 2021

01-

ASBESTOS ABATEMENT PLAN 100% CONTRACT DOCUMENTS REMODEL B MOD OKLAHOMA VAMC

- OKLAHOMA CITY, OK

1/4" = 1'-0"

PARTIAL GROUND LEVEL PLAN - ASBESTOS ABATEMENT

Note Number Note

1 ACTUAL MATERIAL COVERS WHOLE AREA IN SMALL ISOLATED

LOCATIONS.

DN

UP

GENERAL NOTES

LEGEND

ELIGIBILITY

GF103cLOW VISION

GF104

ELIGIBILITY

GF103aELIGIBILITY

GF103b

ELIGIBILITY

GF123

ELIGIBILITY

GF105

MAS SUPPLY

GF106

MY HEALTHY VET

GF107

SOCIAL WORKER

GF108

PSYCHOLOGIST

GF109

CLEAN SUPPLY

GF110

MED ROOM

GF111

EXAM

GF11…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .