Product Data Sheets.pdf

PDF 6 MB Posted

Attached to
Z2DA--635-19-101 Renovate B-Mod Construction (plus up) (VA-22-00016600)
Solicitation number
36C25922R0012
Issued by

About this file

This is a solicitation for renovation construction services at a Veterans Affairs medical center. The solicitation seeks offers for construction work including plumbing, electrical, and HVAC upgrades at Building 101 located at the VA medical center in Oklahoma City, Oklahoma. Bids are due by February 22, 2022 and the period of performance is 270 days from award. The work is to be performed under a firm-fixed-price contract awarded to the responsible bidder submitting the lowest price. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19.

View the file

Other files

File Type Posted
36C25922R0012 0008.docx DOCX document
36C25922R0012 0008.docx DOCX document
36C25922R0012 0007.docx DOCX document
36C25922R0012 0006.docx DOCX document
36C25922R0012 0005.docx DOCX document
SECTION 03 30 00 Cast in Place Concrete.docx DOCX document
013216.15 PROJECT SCHEDULES.pdf PDF
080671_Door_Hardware_Schedule_2022-01-21.pdf PDF
VA02821319-Floor tile and Mastic OK VA(rev).docx DOCX document
09 68 00 CARPETING .pdf PDF
OKC PACT Renovation AE601.pdf PDF
105126.18 Solid Plastic Lockers (3).pdf PDF
Hollow Metal Doors and Frames.pdf PDF
087113_Automatic_Door_Operators.pdf PDF
36C25922R0012 0004.docx DOCX document
OKC PACT Renovation Updated Drawings Final.pdf PDF
092400 PORTLAND CEMENT PLASTER.pdf PDF
Asbestos Building 1 Inventory.xlsx XLSX spreadsheet
2020-0647.20 F1 ACM 1-20-2022.pdf PDF
122400 Window Shades.pdf PDF
275223 - Nurse Call Systems.pdf PDF
14 92 00 PNEUMATIC TUBE SYSTEM.pdf PDF
Integrated Access Control Hardware Devices.pdf PDF
092513.13 ACRYLIC PLASTER FINISH.pdf PDF
087100_Door_Hardware.pdf PDF
090600-SCHEDULE OF FINISHES (1).pdf PDF
36C25922R0012 0003.docx DOCX document
Pre-Bid Site Walk Attendance sheet.pdf PDF
36C25922R0012 0002.docx DOCX document
36C25922R0012 0001.docx DOCX document
36C25922R0012_1.docx DOCX document
3 10 2021 Past Performance Questionnaire.docx DOCX document
OKC B-Mod Drawings.pdf PDF
OKC B-Mod Specifications.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Job Name

RENOVATE B-MOD FOR PACT

OKLAHOMA CITY OK

FF00010 Page 1/1Ingen Software, Inc.

Jan 11, 2022

RE: RENOVATE B-MOD FOR PACT

OKLAHOMA CITY OK

Type MFG Part

A1 METALUX 24CZ2-50-UNV-L840-CD1-U

A2 METALUX 22CZ2-34HE-UNV-L840-CD1-U

A2E METALUX 22CZ2-34HE-UNV-EL7W-L840-CD1-U

B OXYGEN 3-559-24

C METALUX 4SLSTP4050DD-UNV

CE METALUX 4SLSTP4050DD-UNV EBPLED7W

D HALO COMM HC615D010 HM612840 61MDHWF

X SURE-LITES EUR71R

OS GGATE-SENS OAC-DT-2000

PP GGATE-SENS SP20-MV

SOS GGATE-SENS ONW-D-1001-MV-W

SOS3 GGATE-SENS ONW-D-1001-MV-W

SD GGATE-SENS WBSD-010SLD-W

SLV GGATE-SENS GMDS-W

PP GGATE-SENS SP20-RD4

Job Name:

Catalog Number:

24CZ2-50-UNV-L840-CD1-U

Notes:

Type:

A1

PS519306EN page 1 November 19, 2020 3:19 PM

Project Catalog # Type

Prepared by Notes Date

Top Product Features

• Latch-less design provides clean architectural look

• VividTune CCT tuning options from 3000K-5000K or 2700K-6500K

• Designers delight - ribbed, smooth and round perforated lens options

• High performance efficacy up to 167 lm/W

• Integrated sensor systems - occupancy, daylight and IoT connectivity

Dimensional and Mounting Details

Cruze ST 24CZ2

2' x 4' LED Specification Grade Troffer

Typical Applications

Office • Education • Healthcare • Hospitality • Retail

Interactive Menu

• Order Information page 2

• Photometric Data page 3

• Connected Systems page 5

• VividTuneTM Color Tuning Solutions page 6

• Product Warranty

3-1/4" [83mm] *

23-3/4" [603mm]

7" [179mm]

*When combined with emergency total height is increased by 1 inch.

Shielding

HRP - High-Efficiency Round Perf Inlay

See ordering information for more shielding options.

SQR - Square Lens

23-3/4" [603mm]

10-1/2" [267mm]

15" [381mm]

47-3/4" [1213mm]

Ceiling Trim Type Type Exposed Grid Standard Concealed T Standard Slot Grid Standard Flange *

G Grid/Lay-in Standard

G Concealed T

G Slot Grid

*See Drywall Frame Kit Accessory in Ordering Information Section

Ceiling Compatibility

Product Certification

Product Features

Index Page1/6

Catalog Number:

24CZ2-50-UNV-L840-CD1-U

Notes:

Type:

A1

24CZ2 LED

PS519306EN page 2 November 19, 2020 3:19 PM

Order Information

SAMPLE ORDER NUMBER: 24CZ2-45HE-UNV-L835-CD1-U

Rating Series Air Lumen Output Shielding Voltage

Rating Series Air Lumen Level Efficacy Shielding Voltage (8)

[Blank]=Standard

ATW-SW4=

Chicago Rated

24CZ2=2x4 Cruze ST

[Blank]=Standard A=Air (Vented) (1)

30=3000 Lumens 35=3500 Lumens 40=4000 Lumens 45=4500 Lumens 50=5000 Lumens 55=5500 Lumens (2)

60=6000 Lumens (2)

65=6500 Lumens (2), (3), (4)

70=7000 Lumens 75=7500 Lumens (3), (4)

80=8000 Lumens (3)

85=8500 Lumens (3)

90=9000 Lumens (3)

95=9500 Lumens (3)

100=10000 Lumens (3)

110=11000 Lumens (3)

120=12000 Lumens (3)

130=13000 Lumens (3)

150=15000 Lumens (3)

170=17000 Lumens (3)

[Blank]=Standard Efficacy (5)

HE=High Efficacy (6)

VHE=Very High Efficacy (3), (18)

[Blank]=Ribbed Frosted Acrylic Lens (standard) S=Smooth Frosted Acrylic Lens RDP=Smooth Lens with Round Pattern Insert HRP=High-Efficiency Round Perf Inlay SQR=Square Lens

UNV=Universal Voltage 120-277 347V=347 Volt (9)

48V=48 Volt Low-voltage (Class 2) (C)

Notes Notes Notes

(1) Air version is intended for air return through plenum. See air return data table for air flow volumes.Air option not available with ATW-SW4.

(2) Not available with white tuning and Standard Efficacy. (3) Currently only available with CD driver option. (4) 6500 lumens standard efficacy and 7500 lumens and higher are not available with WN driver. (5) Available up to 6500 lumens. (6) Available up to 7500 lumens. (18) Requires 2 CD-1 drivers above 100VHE.

(8) Products also available in non-US voltages and frequencies for international markets. (9) Some 347V versions require a transformer. Total wattage will increase by 2 watts if used. (C) Consult DLVP system pages for additional details and compatibility.

Options Emergency Options CRI/CCT Flex

Options Emergency Options CRI/CCT Flex

GL=Single Element Fuse GM=Double Element Fuse

[Blank]=No emergency EL7W=7-watt 120V-277V emergency battery pack (10)

EL14W=14-watt 120V-277V emergency battery pack (10)

EL10WSD=Bodine 10W emergency battery pack with self diagnostic installed (10), (20)

ELV7W=7-watt DLVP-compatible low voltage emergency battery pack (C)

ELV14W=14-watt DLVP-compatible low voltage emergency battery pack (C)

ETRD=Iota Emergency Transfer Relay with dimming control (11)

RRU=LVS Controls Emergency Transfer Relay with dimming control (11)

UEL7W=UL924 Listed luminaire, 7-watt, 120V-277V emergency battery pack (10)

UEL14W=UL924 Listed luminaire, 14-watt 120V-277V emergency battery pack (10)

UEL10WSD=Bodine 10W emergency battery pack with self diagnostic installed (10), (21) UETRD=UL924 Listed luminaire, Iota Emergency Transfer Relay with dimming control (11)

URRU=UL924 Listed luminaire, LVS Controls Emergency Transfer Relay with dimming control (11)

L830=80CRI, 3000K

L835=80CRI, 3500K

L840=80CRI, 4000K

L850=80CRI, 5000K

L930=90CRI, 3000K

L935=90CRI, 3500K

L940=90CRI, 4000K

L950=90CRI, 5000K

L83050=80CRI 3000K-5000K

White Tuning (12)

L93050=90CRI 3000K-5000K

White Tuning (12)

L82765=80CRI 2700K-6500K

White Tuning (12)

L92765=90CRI 2700K-6500K

White Tuning (12)

[Blank]=No Flex A3/8-4/18GDIM=3/8" Flex with 0-10V Dimming Leads A3/8-2/18G=3/8" Flex with line and common A3/8-5/18GDIM=Flex with 0-10V Dimming leads and Blue for alternate wiring. See below for details.

Notes Notes

(12) White tuning provides correlated color temperatures (CCT) between 3000K (warm) to 5000K (cool) or 2700K (warm) to 6500K (cool). Must be used in conjunction with W2A driver only.

Must be used with two (2) 10V dimming control channels, 1 color, 1 intensity. May be combined with Wavelinx sensor control systems only.

Flexible Metal Conduit Options

Flex options available for 0-10V dimming control, DALI dimming control, emergency and night light functions. 72-inch factory-installed and pre-wired to driver, fitted to luminaire housing access plate with 90° enclosed FMC connector. Not all options may be combined and installation ratings vary by type. See online configurator for all flex options.

A3/8-4/18GDIM series notes: Factory installed dimming option 3/8” flexible metal conduit with 2-#18 power and ground wires and 2-#18 UL-listed jacketed 0-10V +/- control wires.

Meets UL 66, 83, 1479, 1569, 1581, 2556. NEC® 250.118, 300.22(C), 392, 396, 330, 501, 502, 503, 530, 504, 505, 518, 520, 530, 645, 72; Federal Specification A-A-59544 (formerly J-C-30B); all applicable OSHA and HUD Requirements. UL Classified 1-, 2-, and 3-hour through penetration with applicable fire stop product (not included). May be surface mounted, fished and/or embedded in plaster. Cable tray and approved raceway rated, install per NEC®; Environmental Air-Handling Space Installation per NEC® 300.22(C).

(10) Factory installed with integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens).

IES-format photometry for luminaire under emergency operation available. Battery option increases total height by 1 inch. (11) Used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided by others). Devices are universal voltage (UNV). 347 not available. (20) EL10WSD not available with 347V. (21) UEL10WSD not available with 347V. (C) Consult DLVP system pages for additional details and compatibility.

Driver Type Number of Drivers Integrated Sensing Systems Packaging

Driver Type Number of Drivers Integrated Sensing Systems (15) Packaging

CD=0-10V Dimming Driver (1%-100% Dimming) WN=WaveLinx Wireless Fixture, No Sensor. (A), (G), (H), (19)

5LTD=Fifth Light DALI Driver (5%-100% Dimming) (E)

5LTHD=Fifth Light Dimming Driver (1%-100% Dimming) (E)

LV=DLVP Dimming Driver (0%-100% Dimming) (C)

SD=Step Dimming Driver (50%-100% Dimming) LH=Lutron HiLume (LDE1 series) 1%-100% EcoSystem Driver with Soft-on Fade to Black dimming (F)

L5=Lutron 5 Series (LDE5-Series) 5%-100% EcoSystem Driver (F)

W2A=White Tuning, 2 ch, Analog 0-10V Intensity and CCT Control (13)

SR=Sensor-ready Dimming Driver (1%-100% Dimming)

1=1 Driver 2=2 Drivers (14)

[Blank]=No Sensor WAA=WaveLinx Wireless Integrated Sensor (A)

WAB=WaveLinx Lite Wireless Integrated Sensor (B)

SLVPD1=Low-voltage Integrated Sensor (C)

SVPD1=0-10V Stand-alone Integrated Sensor (D)

U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton

Notes Notes Notes

(13) White tuning provides correlated color temperatures (CCT) between 3000K (warm) to 5000K (cool) or 2700K (warm) to 6500K (cool). Must be used in conjunction with W2A driver only. Must be used with two (2) 10V dimming control channels, 1 color, 1 intensity. May be combined with Wavelinx sensor control systems only. (19) Not available 30.

Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (A) Consult WaveLinx system pages for additional details and compatibility. (C) Consult DLVP system pages for additional details and compatibility. (E) Consult Fifth Light system pages for additional details and compatibility. (F) Consult Marketplace Options - Lutron system pages for additional details and compatibility. Compatible only with driver series shown, and may require two or more drivers. Requires field commissioning to operate or dim. Contact Lutron at www.lutron.com. (G) Not compatible with GTR, ETRD, or integrated sensor options. (H) Available with UNV voltage only.

(14) See lumen limitation notes for applications requiring 2 drivers or use online configurator. When combined with emergency total height is increased by 1 inch.

(15) Matching width lens band on other side of sensor band may be supplied for symmetrical appearance. Required for use with sensor and emergency combination. Add "D" to sensor ordering as shown - WAAD, WABD, SDVPD1.

Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (A) Consult WaveLinx system pages for additional details and compatibility. (B) WaveLinx Lite devices are not currently compatible with the WaveLinx Wireless Area Controller. Consult WaveLinx Lite system pages for additional details and compatibility. (C) Consult DLVP system pages for additional details and compatibility. (D) Consult SVPD series system pages for additional details and compatibility.

Index Page2/6

Catalog Number:

24CZ2-50-UNV-L840-CD1-U

Notes:

Type:

A1

24CZ2 LED

PS519306EN page 3 November 19, 2020 3:19 PM

Photometric Data View IES files

24CZ2-35-UNV-L830-CD1-U

Dimming Driver Linear LED 3000K Spacing criterion: (II) 1.22 x mounting height, (⊥) 1.28 x mounting height Lumens: 3618 Input Watts: 30.1W Efficacy: 120.2 LPW Test Report: 24CZ2-35-UNV-L830-CD1-U.IES

24CZ2-35HE-UNV-L830-CD1-U

Dimming Driver Linear LED 3000K Spacing criterion: (II) 1.21 x mounting height, (⊥) 1.27 x mounting height Lumens: 3562 Input Watts: 26.9W Efficacy: 132.4 LPW Test Report: 24CZ2-35HE-UNV-L830-CD1-U.IES

View IES files

Accessories

Accessories (order separately)

CZ2-EQCLIP-U-PK=“CZ2” Earthquake Clip Kit (4 clips per bag kit) (16) DF-24W-U=2' x 4' Drywall Frame Kit SK-24-WS=2' x 4' Shallow Surface Mount Kit SK-24-WT=2’ x 4' Tall Surface Mount Kit ISHH-01=Programming Remote for Integrated Sensor (D) ISHH-02=Personal Control Remote for Integrated Sensor (D)

Notes

(16) An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture.

Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (D) For use with SVPD sensor only. Consult SVPD series system pages for additional details and compatibility.

Product Specifications Construction

• Die formed of code gauge prime cold rolled steel with full length die-formed stiffeners

• Unibody endplates attached with interlocking tabs and screws

• Hemmed side flanges

• Four auxiliary fixture end suspension points

• Integral Grid-lock feature for endplates for added safety

• Optional earthquake clips available

Integrated Controls

• 0-10V dimming to 1% standard

• WaveLinx wireless fixture for sensor-less wireless control

• WaveLinx wireless sensor compatible for standalone, controlled, connected, and IoT capability

• SVPD sensor compatible for standalone functionality

• Low-voltage sensor and driver compatible for DLVP applications

• DALI 2.0, Lutron, and step-dimming available

LED and Light Engine

• LED’s available in 3000K, 3500K, 4000K, or 5000K at

80 CRI minimum and 90 CRI minimum

• Color accuracy ≤3-Step MacAdam ellipse (SDCM)

• TM21 life at 60,000 hours up to L94 and calculated

L70 exceeds 290,000 hrs.

• Drivers available in 120-277V and 347V

• Tunable white options available with Cooper

Lighting Solutions' Vividtune

Emergency Options

• Optional emergency battery available in 7W and 14W

• 90-minute backup period for code compliance

• Laser point test from floor for ease of use on 7W and 14W versions

• EZ Key feature prevents accidental discharge during construction on 7W and 14W versions

• Integral emergency transfer relay options available

Finish

• Multistage, iron phosphate pretreatment

• 90% reflective, matte white enamel finish

• Full fixture housing painted after fabrication

Shielding

• Ribbed acrylic frosted lens standard

• Optional smooth acrylic frosted lens (S)

• Optional metal perforated acrylic lens (RDP)

• Optional High-Efficiency Round Perf Inlay (HRP)

Compliance

• IC rated for insulation contact

• cULus listed for damp locations

• UL924 luminaire listing available, see Emergency

Options

• RoHS compliant

• Tested to IESNA LM-79 and LM-80

• Stated life tested to TM21 standards

• Can be used for State of California Title 24 high efficacy luminaire

Warranty

• Five-year warranty standard. Optional ten year warranty available.

0˚ 30˚

40˚

50˚

70˚

90˚

20˚

80˚

60˚

10˚

0˚ 30˚

40˚

50˚

70˚

90˚

20˚

80˚

60˚

10˚

Index Page3/6

Catalog Number:

24CZ2-50-UNV-L840-CD1-U

Notes:

Type:

A1

24CZ2 LED

PS519306EN page 4 November 19, 2020 3:19 PM

Standard Efficacy Versions – Single Row of LEDs

Catalog Number Lumens Watts lm/W

24CZ2-30-UNV-L835-CD1-U 3032 24.2 125

24CZ2-35-UNV-L835-CD1-U 3638 30.1 121

24CZ2-40-UNV-L835-CD1-U 4196 36.2 116

24CZ2-45-UNV-L835-CD1-U 4618 42.9 108

24CZ2-50-UNV-L835-CD1-U 5015 48.6 103

24CZ2-55-UNV-L835-CD1-U 5571 50.5 110

24CZ2-60-UNV-L835-CD1-U 6042 55.6 109

24CZ2-65-UNV-L835-CD1-U 6572 62.8 105

High Efficacy Versions – Two Rows of LEDs

Catalog Number Lumens Watts lm/W

24CZ2-30HE-UNV-L835-CD1-U 3014 22.4 135

24CZ2-35HE-UNV-L835-CD1-U 3583 26.9 133

24CZ2-40HE-UNV-L835-CD1-U 4029 30.6 132

24CZ2-45HE-UNV-L835-CD1-U 4582 35.3 130

24CZ2-50HE-UNV-L835-CD1-U 5021 38.6 130

24CZ2-55HE-UNV-L835-CD1-U 5564 43.5 128

24CZ2-60HE-UNV-L835-CD1-U 6011 44.1 136

24CZ2-65HE-UNV-L835-CD1-U 6590 48.9 135

24CZ2-70HE-UNV-L835-CD1-U 7018 51.0 138

24CZ2-75HE-UNV-L835-CD1-U 7572 55.4 137

Energy and Performance Data Shielding

Lumen Adjustment Factors

S RDP HRP SQR

1.05 0.67 0.81 0.96

Lumen Calculator

CCT

Multiplier 80 CRI 90 CRI

3000K 0.994 0.830

3500K 1.00 0.845

4000K 1.00 0.854

5000K 1.065 0.852

Example of Lumen Adjustment Calculation 24CZ2-40-UNV-L835-CD1-U at 90CRI at 3500K

Lumen Adjustment Factor = 0.845 Total Light Output =

4,196 lm x 0.845 = 3,546 lm Efficacy = = 98 lm/W3,546 lm

36.2W

Lumen Maintenance

Version TM-21 Lumen Maintenance

(60,000 hours) (1)

Theoretical L70 (Hours) (2)

Standard > 87% > 162,000

High Efficiency > 94% > 290,000

Very High Efficiency > 94% > 290,000

Notes: (1) Supported by IES TM-21 standards. (2) Theoretical values represent estimations commonly used; however, refer to the IES position on LED Product Lifetime Prediction, IES PS-10-18, that explains proper use of IES TM-21 and LM-80.

Shipping Data

Catalog No. Wt.

Pallet

49"L x 52"W x 46"H

2' x 4' 20.4 lbs. 28

Load Data (Stock Product)

Thd 6%

Power Factor 0.99

Weight (lbs.) 16

Low Temp. Start -20ºC

Very High Efficacy Versions – Three Rows of LEDs

Catalog Number Lumens Watts lm/W

24CZ2-30VHE-UNV-L835-CD1-U 3011 20.4 148

24CZ2-35VHE-UNV-L835-CD1-U 3526 22.8 155

24CZ2-40VHE-UNV-L835-CD1-U 4042 26.2 154

24CZ2-45VHE-UNV-L835-CD1-U 4559 29.6 154

24CZ2-50VHE-UNV-L835-CD1-U 5064 32.7 155

24CZ2-55VHE-UNV-L835-CD1-U 5570 36.1 154

24CZ2-60VHE-UNV-L835-CD1-U 6055 38.7 157

24CZ2-65VHE-UNV-L835-CD1-U 6565 42.2 156

24CZ2-70VHE-UNV-L835-CD1-U 7059 45.7 155

24CZ2-75VHE-UNV-L835-CD1-U 7662 49.9 154

24CZ2-80VHE-UNV-L835-CD1-U 8128 53.8 151

24CZ2-85VHE-UNV-L835-CD1-U 8600 57.9 149

24CZ2-90VHE-UNV-L835-CD1-U 9053 61.8 147

24CZ2-95VHE-UNV-L835-CD1-U 9521 65.6 145

24CZ2-100VHE-UNV-L835-CD1-U 10191 69.6 146

24CZ2-110VHE-UNV-L835-CD2-U 11098 77.4 143

24CZ2-120VHE-UNV-L835-CD2-U 12211 83.6 146

24CZ2-130VHE-UNV-L835-CD2-U 13271 90.7 146

24CZ2-150VHE-UNV-L835-CD2-U 15006 104.2 144

24CZ2-170VHE-UNV-L835-CD2-U 17021 123.4 138

Air Return Volume

Negative Static Pressure (Inches H2O)

Return Air Volume (CFM)

0.05 75

0.1 103

0.2 153

0.25 177

0.3 191

0.45 234

Index Page4/6

Catalog Number:

24CZ2-50-UNV-L840-CD1-U

Notes:

Type:

A1

24CZ2 LED

PS519306EN page 5 November 19, 2020 3:19 PM

The Cruze ST with Integrated Sensor technology provides automatic energy savings without sacrificing performance. The Cruze ST delivers superior lighting with integrated occupancy and daylighting controls.

For standalone and controlled applications, the WaveLinx Lite integral sensor provides out-of-the-box functionality with no gateways required and factory startup is not needed.

When more connectivity is required, the WaveLinx Wireless sensor meets modern code and utility requirements, delivers energy and cost savings, while enabling buildings to become smart buildings.

The WaveLinx Wireless Connected Lighting System combined with Trellix provides an open IoT platform and infrastructure that connects intelligent sensors leveraging the real-estate of the physical light fixture to solve higher complexity problems to deliver actionable insights through the aggregation of valuable data.

Systems comparison chart Cooper Lighting Solutions provides many lighting system solutions designed to satisfy code requirements and meet the unique needs of any project.

Note: Installation of integrated sensors within 3-ft (1m) of HVAC air vents is not recommended. The pattern shown is intended solely as a general guide and is not to scale.

Standalone Controlled Connected Enterprise WaveLinx Lite WaveLinx Wireless Trellix

Occupancy Yes Yes Yes Yes

Daylighting Yes Yes Yes Yes

Gateways – – 1 WAC 300 WACs

Devices – 50 per Area (1400 per site) 150 per WAC 45,000 per Core Enterprise

Software – WaveLinx Lite Mobile App WaveLinx Mobile App Trellix Core

Areas – 28 per Site 16 per WAC up to 4,800

Zones – 16 per Area 16 per Area up to 76,800

Scheduling – – Local Global

VividTune™ – – Yes Yes

Plug-Load Control – – Yes Yes

Integration – – – BACnet, API

Dashboards – – – Energy, Occupancy

Configuration – Installer Technician Technician / IT

SCALABILITY

WaveLinx Lite expands from a single standalone device up to Enterprise with 45,000 devices devices areas floors buildings

2.4m (8ft)

0m (0ft)

4.5m (15ft)

4.5m

(15FT)

0m (0ft)

CL

4.5m

(15FT)

4.5m

(15FT)

0m (0ft)

CL

2.25m

(7.5FT)

2.25m (7.5ft)

3.0m (10ft)

4.5m

(15FT)

TOP VIEW:

SIDE VIEW:

Note: The "beam" pattern obtained depends strongly on the detector used with this array. The pattern shown is intended solely as a general guide and is not to scale.

2.4m (8ft)

0m (0ft)

4.5m (15ft)

4.5m

(15FT)

0m (0ft)

CL

4.5m

(15FT)

4.5m

(15FT)

0m (0ft)

CL

2.25m

(7.5FT)

2.25m (7.5ft)

3.0m (10ft)

4.5m

(15FT)

TOP VIEW:

SIDE VIEW:

Note: The "beam" pattern obtained depends strongly on the detector used with this array. The pattern shown is intended solely as a general guide and is not to scale.

Control Systems

• WaveLinx Wireless

• WaveLinx Wired

• WaveLinx Lite

• DLVP

• VividTune

Index Page5/6

Catalog Number:

24CZ2-50-UNV-L840-CD1-U

Notes:

Type:

A1

24CZ2 LED

PS519306EN page 6 November 19, 2020 3:19 PM

Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com

© 2020 Cooper Lighting Solutions All Rights Reserved.

Specifications and dimensions subject to change without notice.

2' x 4' Cruze ST LED - Example of Approximate Lumen Calculation

Standard Catalog # VividTune 80 CRI Catalog # VividTune 90 CRI Catalog #

CCT

Setting 24CZ2-40HE-UNV-L835-CD1-U 24CZ2-40HE-UNV-L83050-W2A1-U 24CZ2-40HE-UNV-L93050-W2A1-U

3000K - 3641 2998

3500K 4029 3853 3275

4000K - 4046 3537

4500K - 4084 3599

5000K - 4084 3599

Performance Data*

24 Cruze ST LED with VividTune Tunable White VividTune tunable white luminaires from Cooper Lighting Solutions deliver high-quality light in a broad range of continuously variable color temperatures and intensities. Create a dynamic environment by adjusting the ambient light warmer or cooler to influence mood, support the task at hand, or create a dramatic ambience.

The ability to control correlated color temperature and intensity separately using simple controls is the next evolution of LED lighting for the commercial, educational, healthcare and hospitality space. The unparalleled flexibility and number of available lighting environments enable users to find the right light with tunable white.

Tunable White - Lumen Adjustment Factors

CCT

3000K-5000K 2700K-6500K

80 CRI 90 CRI 80 CRI 90 CRI

2700K - - 0.878 0.750

3000K 0.904 0.744 0.903 0.779

3500K 0.956 0.813 0.934 0.819

4000K 1.004 0.878 0.954 0.844

4500K 1.014 0.893 0.972 0.866

5000K 1.014 0.893 0.985 0.884

6500K - - 0.999 0.908

Example of Lumen Adjustment Calculation

24CZ2-40HE-UNV-L83050-W2A1-U

at 80 CRI tuned to 3500K

Adjusted Lumen = published lm x adjusted lm factor

Adjusted Lumen = 4029 x 0.956

Adjusted Lumen = 3853 lm

* Lumen adjustment factors are for reference and may be different for each product selected.

Refer to IES files for actual performance data on each.

Controlling VividTune Tunable White VividTune luminaires make tunable white more accessible by using simple and familiar controls. From wall dimmers to wireless controls, VividTune tunable white luminaires are compatible with industry standard 0-10V dimming controls. A single 0-10V dimming input is used to control intensity (brightness) while a second 0-10V dimming input is used to adjust CCT. For suggested control configurations, go to www.cooperlighting.com for tunable white application guides.

warm 2700K cool 6500KCCT 0-10V warm 3000K cool 5000KCCT 0-10V

10% 100%Intensity 0-10V

Index Page6/6

Catalog Number:

22CZ2-34HE-UNV-L840-CD1-U

Notes:

Type:

A2

PS519305EN page 1 April 6, 2021 3:06 PM

Project Catalog # Type

Prepared by Notes Date

Top Product Features

• Latch-less design provides clean architectural look

• VividTune CCT tuning options from 3000K-5000K or 2700K-6500K

• Designers delight - ribbed, smooth and round perforated lens options

• High performance efficacy up to 151 lm/W

• Integrated sensor systems - occupancy, daylight and IoT connectivity

Dimensional and Mounting Details

Cruze ST 22CZ2

2' x 2' LED Specification Grade Troffer

Typical Applications

Office • Education • Healthcare • Hospitality • Retail

Ceiling Trim Type Type Exposed Grid Standard Concealed T Standard Slot Grid Standard Flange *

G Grid/Lay-in Standard

G Concealed T

G Slot Grid

*See Drywall Frame Kit Accessory in Ordering Information Section

Ceiling Compatibility

Interactive Menu

• Order Information page 2

• Photometric Data page 3

• Connected Systems page 5

• VividTuneTM Color Tuning Solutions page 6

• Product Warranty

3-1/4" [83mm]

23-3/4" [603mm]

7" [179mm]

23-3/4" [603mm]

10-1/2" [267mm]

15" [381mm] 23-3/4" [603mm]

Shielding

HRP - High-Efficiency Round Perf Inlay

See ordering information for more shielding options.

SQR - Square Lens

Product Certification

Catalog Number:

22CZ2-34HE-UNV-L840-CD1-U

Notes:

Type:

A2

22CZ2 LED

PS519305EN page 2 April 6, 2021 3:06 PM

Order Information

SAMPLE ORDER NUMBER: 22CZ2-34HE-UNV-L835-CD1-U

Rating Series Air Lumen Output Shielding Voltage Options

Rating Series Air Lumen Level Efficacy Shielding Voltage (8) Options

[Blank]=Standard

ATW-SW4=

Chicago Rated

22CZ2=2x2 Cruze ST

[Blank]=Standard A=Air (Vented) (1)

20=2000 Lumens (2)

24=2400 Lumens (2)

29=2900 Lumens (7)

32=3200 Lumens (6)

34=3400 Lumens (7)

39=3900 Lumens 44=4400 Lumens 50=5000 Lumens (5)

55=5500 Lumens (5)

60=6000 Lumens (5)

65=6500 Lumens (5)

70=7000 Lumens (5)

75=7500 Lumens (5)

80=8000 Lumens (5)

85=8500 Lumens (5)

90=9000 Lumens (5)

95=9500 Lumens (5)

100=10000 Lumens (5)

110=11000 Lumens (5)

[Blank]=Standard Efficacy (3), (4)

HE=High Efficacy (4)

VHE=Very High Efficacy (5)

[Blank]=Ribbed Frosted Acrylic Lens (standard) S=Smooth Frosted Acrylic Lens RDP=Smooth Lens with Round Pattern Insert HRP=High-Efficiency Round Perf Inlay SQR=Square Lens

UNV=Universal Voltage 120-277 347V=347 Volt 48V=48 Volt Low-voltage (Class 2) (C)

GL=Single Element Fuse GM=Double Element Fuse

Notes Notes Notes

(1) Air version is intended for air return through plenum. See air return data table for air flow volumes.Air option not available with ATW-SW4.

(2) Not available with WN driver. (3) White tuning not available with this model.

(4) Available up to 4400 lumens. (5) Currently only available with CD driver option. (6) Only available in Standard Efficacy. (7) Not available in Standard Efficacy.

(8) Products also available in non-US voltages and frequencies for international markets. (C) Consult WaveLinx Low-Voltage or DLVP system pages for additional details and compatibility.

Emergency Options CRI/CCT Flex

Emergency Options CRI/CCT Flex

[Blank]=No emergency EL7W=7-watt 120V-277V emergency battery pack (9)

EL14W=14-watt 120V-277V emergency battery pack (9)

EL10WSD=Bodine 10W emergency battery pack with self diagnostic installed (9), (11)

ELV7W=Low-voltage system, 7-watt emergency battery pack (C)

ELV14W=Low-voltage system, 14-watt emergency battery pack (C)

ETRD=Iota Emergency Transfer Relay with dimming control (10)

RRU=LVS Controls Emergency Transfer Relay with dimming control (10)

UEL7W=UL924 Listed luminaire, 7-watt, 120V-277V emergency battery pack (9)

UEL14W=UL924 Listed luminaire, 14-watt 120V-277V emergency battery pack (9)

UEL10WSD=Bodine 10W emergency battery pack with self diagnostic installed (9), (12) UETRD=UL924 Listed luminaire, Iota Emergency Transfer Relay with dimming control (10)

URRU=UL924 Listed luminaire, LVS Controls Emergency Transfer Relay with dimming control (10)

L830=80CRI, 3000K

L835=80CRI, 3500K

L840=80CRI, 4000K

L850=80CRI, 5000K

L930=90CRI, 3000K

L935=90CRI, 3500K

L940=90CRI, 4000K

L950=90CRI, 5000K

L83050=80CRI 3000K-5000K White Tuning (13)

L93050=90CRI 3000K-5000K White Tuning (13)

L82765=80CRI 2700K-6500K White Tuning (13)

L92765=90CRI 2700K-6500K White Tuning (13)

[Blank]=No Flex A3/8-4/18GDIM=3/8" Flex with 0-10V Dimming Leads A3/8-2/18G=3/8" Flex with line and common A3/8-5/18GDIM=Flex with 0-10V Dimming leads and Blue for alternate wiring. See below for details.

Notes Notes

(13) White tuning provides correlated color temperatures (CCT) between 3000K (warm) to 5000K (cool) or 2700K (warm) to 6500K (cool). Must be used in conjunction with W2A driver only. Must be used with two (2) 10V dimming control channels, 1 color, 1 intensity. May be combined with Wavelinx sensor control systems only.

Flexible Metal Conduit Options

Flex options available for 0-10V dimming control, DALI dimming control, emergency and night light functions. 72-inch factory-installed and pre-wired to driver, fitted to luminaire housing access plate with 90° enclosed FMC connector. Not all options may be combined and installation ratings vary by type. See online configurator for all flex options.

A3/8-4/18GDIM series notes: Factory installed dimming option 3/8” flexible metal conduit with 2-#18 power and ground wires and 2-#18 UL-listed jacketed 0-10V +/- control wires.

Meets UL 66, 83, 1479, 1569, 1581, 2556. NEC® 250.118, 300.22(C), 392, 396, 330, 501, 502, 503, 530, 504, 505, 518, 520, 530, 645, 72; Federal Specification A-A-59544 (formerly J-C-30B); all applicable OSHA and HUD Requirements. UL Classified 1-, 2-, and 3-hour through penetration with applicable fire stop product (not included). May be surface mounted, fished and/or embedded in plaster. Cable tray and approved raceway rated, install per NEC®; Environmental Air-Handling Space Installation per NEC® 300.22(C).

(9) Factory installed with integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens).

IES-format photometry for luminaire under emergency operation available. Battery option increases total height by 1 inch. (10) Used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided by others). Devices are universal voltage (UNV). 347 not available. (11) EL10WSD not available with 347V. (12) UEL10WSD not available with 347V. (C) Consult WaveLinx Low-Voltage or DLVP system pages for additional details and compatibility.

Driver Type Number of Drivers Integrated Sensing Systems Packaging Accessories

Driver Type Number of Drivers Integrated Sensing Systems (15) Packaging Accessories (order separately)

CD=0-10V Dimming Driver (1%-100% Dimming) WN=WaveLinx Wireless Fixture, No Sensor. (A), (G), (H)

5LTD=Fifth Light DALI Driver (5%-100% Dimming) (E)

5LTHD=Fifth Light Dimming Driver (1%-100% Dimming) (E)

LV=Low-voltage System Dimming Driver (0%-100% Dimming) (C)

SD=Step Dimming Driver (50%-100% Dimming) LH=Lutron HiLume (LDE1 series) 1%-100% EcoSystem Driver with Soft-on Fade to Black dimming (F)

L5=Lutron 5 Series (LDE5-Series) 5%-100% EcoSystem Driver (F)

W2A=White Tuning, 2 ch, Analog 0-10V Intensity and CCT Control (14)

SR=Sensor-ready Dimming Driver (1%-100% Dimming)

1=1 Driver [Blank]=No Sensor WAA=WaveLinx Wireless Integrated Sensor (16), (A)

WAB=WaveLinx Lite Wireless Integrated Sensor (17), (B)

WLA=Low-voltage Integrated Sensor (18), (C)

SVPD1=0-10V Stand-alone Integrated Sensor (17), (D)

U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton

CZ2-EQCLIP-U-PK=“CZ2” Earthquake Clip Kit (4 clips per bag kit) (19) DF-22W-U=2' x 2' Drywall Frame Kit SK-22-WS=2' x 2' Shallow Surface Mount Kit SK-22-WT=2' x 2' Tall Surface Mount Kit ISHH-01=Programming Remote for Integrated Sensor (D) ISHH-02=Personal Control Remote for Integrated Sensor (D)

Notes Notes Notes

(14) White tuning provides correlated color temperatures (CCT) between 3000K (warm) to 5000K (cool) or 2700K (warm) to 6500K (cool). Must be used in conjunction with W2A driver only. Must be used with two (2) 10V dimming control channels, 1 color, 1 intensity. May be combined with Wavelinx sensor control systems only.

Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (A) Consult WaveLinx system pages for additional details and compatibility. (C) Consult WaveLinx Low-Voltage or DLVP system pages for additional details and compatibility. (E) Consult Fifth Light system pages for additional details and compatibility. (F) Consult Marketplace Options - Lutron system pages for additional details and compatibility. Compatible only with driver series shown, and may require two or more drivers. Requires field commissioning to operate or dim. Contact Lutron at www.lutron.com. (G) Not compatible with GTR, ETRD, or integrated sensor options. (H) Available with UNV voltage only.

(15) Matching width lens band on other side of sensor band may be supplied for symmetrical appearance. Required for use with sensor and emergency combination. Add “D” to sensor ordering as shown - WAAD, WABD, SDVPD1. (16) WAA sensor to be used with CD or W2A driver. (17) WAB and SVPD1 sensor to be used with CD driver. (18) WLA sensor to be used with LV driver.

Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (A) Consult WaveLinx system pages for additional details and compatibility. (B) WaveLinx Lite devices are not currently compatible with the WaveLinx Wireless Area Controller. Consult WaveLinx Lite system pages for additional details and compatibility. (C) Consult WaveLinx Low-Voltage or DLVP system pages for additional details and compatibility. (D) Consult SVPD series system pages for additional details and compatibility.

(19) An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture.

Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories.

Please refer to the following: (D) For use with SVPD sensor only. Consult SVPD series system pages for additional details and compatibility.

Catalog Number:

22CZ2-34HE-UNV-L840-CD1-U

Notes:

Type:

A2

22CZ2 LED

PS519305EN page 3 April 6, 2021 3:06 PM

Photometric Data

22CZ2-24-UNV-L830-CD1-U

Dimming Driver Linear LED 3000K Spacing criterion: (II) 1.2 x mounting height, (⊥)

1.28 x mounting height Lumens: 2437 Input Watts: 21.9W Efficacy: 111.3 LPW Test Report: 22CZ2-24-UNVL830-CD1-U.IES

22CZ2-24HE-UNV-L830-CD1-U

Dimming Driver Linear LED 3000K Spacing criterion: (II) 1.19 x mounting height, (⊥)

1.27 x mounting height Lumens: 2402 Input Watts: 19.2W Efficacy: 125.1 LPW Test Report: 14CZ2-29-UNV-L830-CD1-U.IES

0˚ 30˚

40˚

50˚

70˚

90˚

20˚

80˚

60˚

10˚

0˚ 30˚

40˚

50˚

70˚

90˚

20˚

80˚

60˚

10˚

Product Specifications Construction

• Die formed of code gauge prime cold rolled steel with full length die-formed stiffeners

• Unibody endplates attached with interlocking tabs and screws

• Hemmed side flanges

• Four auxiliary fixture end suspension points

• Integral Grid-lock feature for endplates for added safety

• Optional earthquake clips available

Integrated Controls

• 0-10V dimming to 1% standard

• WaveLinx wireless fixture for sensor-less wireless control

• WaveLinx wireless sensor compatible for standalone, controlled, connected, and IoT capability

• SVPD sensor compatible for standalone functionality

• Low-voltage sensor and driver compatible for

WaveLinx Low-Voltage and DLVP applications

• DALI 2.0, Lutron, and step-dimming available

LED and Light Engine

• LED’s available in 3000K, 3500K, 4000K, or 5000K at

80 CRI minimum and 90 CRI minimum

• Color accuracy ≤3-Step MacAdam ellipse (SDCM)

• TM21 life at 60,000 hours up to L90 and calculated

L70 exceeds 203,000 hrs.

• Drivers available in 120-277V and 347V

• Tunable white options available with Cooper

Lighting Solutions’ Vividtune

Emergency Battery Options

• Optional emergency battery available in 7W and 14W

• 90-minute backup period for code compliance

• Laser point test from floor for ease of use on 7W and 14W versions

• EZ Key feature prevents accidental discharge during construction on 7W and 14W versions

• Integral emergency transfer relay options available

Finish

• Multistage, iron phosphate pretreatment

• 90% reflective, matte white enamel finish

• Full fixture housing painted after fabrication

Shielding

• Ribbed acrylic frosted lens standard

• Optional smooth acrylic frosted lens (S)

• Optional metal perforated acrylic lens (RDP)

• Optional High-Efficiency Round Perf Inlay (HRP)

Compliance

• IC rated for insulation contact

• cULus listed for damp locations

• RoHS compliant

• Tested to IESNA LM-79 and LM-80

• Stated life tested to TM21 standards

• Can be used for State of California Title 24 high efficacy luminaire

Warranty

• Five-year warranty standard. Optional ten year warranty available.

View IES files

Catalog Number:

22CZ2-34HE-UNV-L840-CD1-U

Notes:

Type:

A2

22CZ2 LED

PS519305EN page 4 April 6, 2021 3:06 PM

Standard Efficacy Versions – Single Row of LEDs

Catalog Number Lumens Watts lm/W

22CZ2-20-UNV-L835-CD1-U 2142 16.2 132

22CZ2-24-UNV-L835-CD1-U 2454 18.5 133

22CZ2-32-UNV-L835-CD1-U 3272 24.2 135

22CZ2-39-UNV-L835-CD1-U 3953 31 128

22CZ2-44-UNV-L835-CD1-U 4462 33 134

High Efficacy Versions – Two Rows of LEDs

Catalog Number Lumens Watts lm/W

22CZ2-20HE-UNV-L835-CD1-U 2030 15.0 135

22CZ2-24HE-UNV-L835-CD1-U 2474 18.1 137

22CZ2-29HE-UNV-L835-CD1-U 2982 20.9 143

22CZ2-34HE-UNV-L835-CD1-U 3426 24.3 141

22CZ2-39HE-UNV-L835-CD1-U 3997 28.5 140

22CZ2-44HE-UNV-L835-CD1-U 4567 32.8 139

Energy and Performance Data

Lumen Maintenance

Version TM-21 Lumen Maintenance

(60,000 hours) (2)

Theoretical L70 (Hours) (3)

Standard > 85% > 151,000

High Efficiency > 90% > 203,000

Very High Efficiency > 90% > 203,000

Notes: (2) Supported by IES TM-21 standards. (3) Theoretical values represent estimations commonly used; however, refer to the IES position on LED Product Lifetime Prediction, IES PS-10-18, that explains proper use of IES TM-21 and LM-80.

Shipping Data

Catalog No. Wt.

Pallet

49"L x 52"W x 55"H

2' x 2' 12.5 lbs. 48

Load Data (Stock Product)

Thd 6%

Power Factor 0.99

Weight (lbs.) 10.6

Low Temp. Start -20ºC

Very High Efficacy Versions – Three Rows of LEDs

Catalog Number Lumens Watts lm/W

22CZ2-20VHE-UNV-L835-CD1-U 2008 14.2 141

22CZ2-24VHE-UNV-L835-CD1-U 2501 17.5 143

22CZ2-29VHE-UNV-L835-CD1-U 3114 21.7 144

22CZ2-34VHE-UNV-L835-CD1-U 3598 25.1 143

22CZ2-39VHE-UNV-L835-CD1-U 4078 28.6 143

22CZ2-44VHE-UNV-L835-CD1-U 4620 32.6 142

22CZ2-50VHE-UNV-L835-CD1-U 5095 36.2 141

22CZ2-55VHE-UNV-L835-CD1-U 5530 39.4 140

22CZ2-60VHE-UNV-L835-CD1-U 6110 44.1 139

22CZ2-65VHE-UNV-L835-CD1-U 6559 47.9 137

22CZ2-70VHE-UNV-L835-CD1-U 7017 50.3 140

22CZ2-75VHE-UNV-L835-CD1-U 7557 54.7 138

22CZ2-80VHE-UNV-L835-CD1-U 8092 59.1 137

22CZ2-85VHE-UNV-L835-CD1-U 8615 63.6 136

22CZ2-90VHE-UNV-L835-CD1-U 9125 68.2 134

22CZ2-95VHE-UNV-L835-CD1-U 9610 72.7 132

22CZ2-100VHE-UNV-L835-CD1-U 10108 77.7 130

22CZ2-110VHE-UNV-L835-CD1-U 11065 87.7 126

Shielding

Lumen Adjustment Factors

S RDP HRP SQR

1.05 0.67 0.80 0.96

Air Return Volume

Negative Static Pressure (Inches H2O)

Return Air Volume (CFM)

0.05 79

0.1 112

0.2 161

0.25 177

0.3 198

0.45 239

Lumen Calculator

CCT

Multiplier 80 CRI 90 CRI (1)

3000K 0.965 0.827

3500K 1.000 0.847

4000K 1.019 0.856

5000K 1.019 0.909

Notes: (1) Input wattages for 90 CRI versions may vary. Refer to published IES-format photometry or LM-79 reports for more details.

Example of Lumen Adjustment Calculation 22CZ2-32-UNV-L935-CD1-U at 90CRI at 3500K

Lumen Adjustment Factor = 0.845 Total Light Output =

3,280 lm x 0.845 = 2,772 lm Efficacy = = 103.8 lm/W2,772 lm

26.7W

Catalog Number:

22CZ2-34HE-UNV-L840-CD1-U

Notes:

Type:

A2

22CZ2 LED

PS519305EN page 5 April 6, 2021 3:06 PM

The Cruze ST with Integrated Sensor technology provides automatic energy savings without sacrificing performance. The Cruze ST delivers superior lighting with integrated occupancy and daylighting controls.

For standalone and controlled applications, the WaveLinx Lite integral sensor provides out-of-the-box functionality with no gateways required and factory startup is not needed.

When more connectivity is required, the WaveLinx Wireless sensor meets modern code and utility requirements, delivers energy and cost savings, while enabling buildings to become smart buildings.

The WaveLinx Wireless Connected Lighting System combined with Trellix provides an open IoT platform and infrastructure that connects intelligent sensors leveraging the real-estate of the physical light fixture to solve higher complexity problems to deliver actionable insights through the aggregation of valuable data.

Note: Installation of integrated sensors within 3-ft (1m) of HVAC air vents is not recommended. The pattern shown is intended solely as a general guide and is not to scale.

2.4m (8ft)

0m (0ft)

4.5m (15ft)

4.5m

(15FT)

0m (0ft)

CL

4.5m

(15FT)

4.5m

(15FT)

0m (0ft)

CL

2.25m

(7.5FT)

2.25m (7.5ft)

3.0m (10ft)

4.5m

(15FT)

TOP VIEW:

SIDE VIEW:

Note: The "beam" pattern obtained depends strongly on the detector used with this array. The pattern shown is intended solely as a general guide and is not to scale.

2.4m (8ft)

0m (0ft)

4.5m (15ft)

4.5m

(15FT)

0m (0ft)

CL

4.5m

(15FT)

4.5m

(15FT)

0m (0ft)

CL

2.25m

(7.5FT)

2.25m (7.5ft)

3.0m (10ft)

4.5m

(15FT)

TOP VIEW:

SIDE VIEW:

Note: The "beam" pattern obtained depends strongly on the detector used with this array. The pattern shown is intended solely as a general guide and is not to scale.

Systems comparison chart Cooper Lighting Solutions provides many lighting system solutions designed to satisfy code requirements and meet the unique needs of any project.

Standalone Controlled Connected Enterprise WaveLinx Lite WaveLinx Wireless Trellix

Occupancy Yes Yes Yes Yes

Daylighting Yes Yes Yes Yes

Gateways – – 1 WAC 300 WACs

Devices – 50 per Area (1400 per site) 150 per WAC 45,000 per Core Enterprise

Software – WaveLinx Lite Mobile App WaveLinx Mobile App Trellix Core

Areas – 28 per Site 16 per WAC up to 4,800

Zones – 16 per Area 16 per Area up to 76,800

Scheduling – – Local Global

VividTune™ – – Yes Yes

Plug-Load Control – – Yes Yes

Low-Voltage Power – – Yes Yes

Integration – – – BACnet, API

Dashboards – – – Energy, Occupancy

Configuration – Installer Technician Technician / IT

SCALABILITY

WaveLinx Lite expands from a single standalone device up to Enterprise with 45,000 devices devices areas floors buildings

Control Systems

• WaveLinx Wireless

• WaveLinx Wired

• WaveLinx Lite

• DLVP

Catalog Number:

22CZ2-34HE-UNV-L840-CD1-U

Notes:

Type:

A2

22CZ2 LED

Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com

© 2021 Cooper Lighting Solutions All Rights Reserved.

Specifications and dimensions subject to change without notice.

PS519305EN page 6 April 6, 2021 3:06 PM

2' x 2' Cruze ST LED - Example of Approximate Lumen Calculation

Standard Catalog # VividTune 80 CRI Catalog # VividTune 90 CRI Catalog #

CCT

Setting 22CZ2-34HE-UNV-L835-CD1-U 22CZ2-34HE-UNV-L83050-W2A1-U 22CZ2-34HE-UNV-L93050-W2A1-U

3000K - 3026 2491

3500K 3386 3202 2722

4000K - 3362 2940

4500K - 3394 2991

5000K - 3394 2991

22 Cruze ST LED with VividTune Tunable White VividTune tunable white luminaires from Cooper Lighting Solutions deliver high-quality light in a broad range of continuously variable color temperatures and intensities. Create a dynamic environment by adjusting the ambient light warmer or cooler to influence mood, support the task at hand, or create a dramatic ambience.

The ability to control correlated color temperature and intensity separately using simple controls is the next evolution of LED lighting for the commercial, educational, healthcare and hospitality space. The unparalleled flexibility and number of available lighting environments enable users to find the right light with tunable white.

Tunable White - Lumen Adjustment Factors

CCT

3000K-5000K 2700K-6500K

80 CRI 90 CRI 80 CRI 90 CRI

2700K - - 0.868 0.741

3000K 0.894 0.736 0.893 0.771

3500K 0.946 0.804 0.924 0.809

4000K 0.993 0.868 0.944 0.835

4500K 1.002 0.883 0.961 0.857

5000K 1.002 0.883 0.974 0.874

6500K - - 0.988 0.897

Example of Lumen Adjustment Calculation

22CZ2-34HE-UNV-L83050-W2A1-U

at 80 CRI tuned to 3500K

Adjusted Lumen = published lm x adjusted lm factor

Adjusted Lumen = 3386 x 0.946

Adjusted Lumen = 3202 lm

* Lumen adjustment factors are for reference and may be different for each product selected.

Refer to IES files for actual performance data on each.

Controlling VividTune Tunable White VividTune luminaires make tunable white more accessible by using simple and familiar controls. From wall dimmers to wireless controls, VividTune tunable white luminaires are compatible with industry standard 0-10V dimming controls. A single 0-10V dimming input is used to control intensity (brightness) while a second 0-10V dimming input is used to adjust CCT. For suggested control configurations, go to www.cooperlighting.com for tunable white application guides.

Performance Data* warm 2700K cool 6500KCCT 0-10V warm 3000K cool 5000KCCT 0-10V

10% 100%Intensity

Catalog Number:

22CZ2-34HE-UNV-EL7W-L840-CD1-

U Notes:

Type:

A2E

PS519305EN page 1 April 6, 2021 3:06 PM

Project Catalog # Type

Prepared by Notes Date

Top Product Features

• Latch-less design provides clean architectural look

• VividTune CCT tuning options from 3000K-5000K or 2700K-6500K

• Designers delight - ribbed, smooth and round perforated lens options

• High performance efficacy up to 151 lm/W

• Integrated sensor systems - occupancy, daylight and IoT connectivity

Dimensional and Mounting Details

Cruze ST 22CZ2

2' x 2' LED Specification Grade Troffer

Typical Applications

Office • Education • Healthcare • Hospitality • Retail

Ceiling Trim Type Type Exposed Grid Standard Concealed T Standard Slot Grid Standard Flange *

G Grid/Lay-in Standard

G Concealed T

G Slot Grid

*See Drywall Frame Kit Accessory in Ordering Information Section

Ceiling Compatibility

Interactive Menu

• Order Information page 2

• Photometric Data page 3

• Connected Systems page 5

• VividTuneTM Color Tuning Solutions page 6

• Product Warranty

3-1/4" [83mm]

23-3/4" [603mm]

7" [179mm]

23-3/4" [603mm]

10-1/2" [267mm]

15" [381mm] 23-3/4" [603mm]

Shielding

HRP - High-Efficiency Round Perf Inlay

See ordering information for more shielding options.

SQR - Square Lens

Product Certification

Catalog Number:

22CZ2-34HE-UNV-EL7W-L840-CD1-

U Notes:

Type:

A2E

22CZ2 LED

PS519305EN page 2 April 6, 2021 3:06 PM

Order Information

SAMPLE ORDER NUMBER: 22CZ2-34HE-UNV-L835-CD1-U

Rating Series Air Lumen Output Shielding Voltage Options

Rating Series Air Lumen Level Efficacy Shielding Voltage (8) Options

[Blank]=Standard

ATW-SW4=

Chicago Rated

22CZ2=2x2 Cruze ST

[Blank]=Standard A=Air (Vented) (1)

20=2000 Lumens (2)

24=2400 Lumens (2)

29=2900 Lumens (7)

32=3200 Lumens (6)

34=3400 Lumens (7)

39=3900 Lumens 44=4400 Lumens 50=5000 Lumens (5)

55=5500 Lumens (5)

60=6000 Lumens (5)

65=6500 Lumens (5)

70=7000 Lumens (5)

75=7500 Lumens (5)

80=8000 Lumens (5)

85=8500 Lumens (5)

90=9000 Lumens (5)

95=9500 Lumens (5)

100=10000 Lumens (5)

110=11000 Lumens (5)

[Blank]=Standard Efficacy (3), (4)

HE=High Efficacy (4)

VHE=Very High Efficacy (5)

[Blank]=Ribbed Frosted Acrylic Lens (standard) S=Smooth Frosted Acrylic Lens RDP=Smooth Lens with Round Pattern Insert HRP=High-Efficiency Round Perf Inlay SQR=Square Lens

UNV=Universal Voltage 120-277 347V=347 Volt 48V=48 Volt Low-voltage (Class 2) (C)

GL=Single Element Fuse GM=Double Element Fuse

Notes Notes Notes

(1) Air version is intended for air return through plenum. See air return data table for air flow volumes.Air option not available with ATW-SW4.

(2) Not available with WN driver. (3) White tuning not available with this model.

(4) Available up to 4400 lumens. (5) Currently only available with CD driver option. (6) Only available in Standard Efficacy. (7) Not available in Standard Efficacy.

(8) Products also available in non-US voltages and frequencies for international markets. (C) Consult WaveLinx Low-Voltage or DLVP system pages for additional details and compatibility.

Emergency Options CRI/CCT Flex

Emergency Options CRI/CCT Flex

[Blank]=No emergency EL7W=7-watt 120V-277V emergency battery pack (9)

EL14W=14-watt 120V-277V emergency battery pack (9)

EL10WSD=Bodine 10W emergency battery pack with self diagnostic installed (9), (11)

ELV7W=Low-voltage system, 7-watt emergency battery pack (C)

ELV14W=Low-voltage system, 14-watt emergency battery pack (C)

ETRD=Iota Emergency Transfer Relay with dimming control (10)

RRU=LVS Controls Emergency Transfer Relay with dimming control (10)

UEL7W=UL924 Listed luminaire, 7-watt, 120V-277V emergency battery pack (9)

UEL14W=UL924 Listed luminaire, 14-watt 120V-277V emergency battery pack (9)

UEL10WSD=Bodine 10W emergency battery pack with self diagnostic installed (9), (12) UETRD=UL924 Listed luminaire, Iota Emergency Transfer Relay with dimming control (10)

URRU=UL924 Listed luminaire, LVS Controls Emergency Transfer Relay with dimming control (10)

L830=80CRI, 3000K

L835=80CRI, 3500K

L840=80CRI, 4000K

L850=80CRI, 5000K

L930=90CRI, 3000K

L935=90CRI, 3500K

L940=90CRI, 4000K

L950=90CRI, 5000K

L83050=80CRI 3000K-5000K White Tuning (13)

L93050=90CRI 3000K-5000K White Tuning (13)

L82765=80CRI 2700K-6500K White Tuning (13)

L92765=90CRI 2700K-6500K White Tuning (13)

[Blank]=No Flex A3/8-4/18GDIM=3/8" Flex with 0-10V Dimming Leads A3/8-2/18G=3/8" Flex with line and common A3/8-5/18GDIM=Flex with 0-10V Dimming leads and Blue for alternate wiring. See below for details.

Notes Notes

(13) White tuning provides correlated color temperatures (CCT) between 3000K (warm) to 5000K (cool) or 2700K (warm) to 6500K (cool). Must be used in conjunction with W2A driver only. Must be used with two (2) 10V dimming control channels, 1 color, 1 intensity. May be combined with Wavelinx sensor control systems only.

Flexible Metal Conduit Options

Flex options available for 0-10V dimming control, DALI dimming control, emergency and night light functions. 72-inch factory-installed and pre-wired to driver, fitted to luminaire housing access plate with 90° enclosed FMC connector. Not all options may be combined and installation ratings vary by type. See online configurator for all flex options.

A3/8-4/18GDIM series notes: Factory installed dimming option 3/8” flexible metal conduit with 2-#18 power and ground wires and 2-#18 UL-listed jacketed 0-10V +/- control wires.

Meets UL 66, 83, 1479, 1569, 1581, 2556. NEC® 250.118, 300.22(C), 392, 396, 330, 501, 502, 503, 530, 504, 505, 518, 520, 530, 645, 72; Federal Specification A-A-59544 (formerly J-C-30B); all applicable OSHA and HUD Requirements. UL Classified 1-, 2-, and 3-hour through penetration with applicable fire stop product (not included). May be surface mounted, fished and/or embedded in plaster. Cable tray and approved raceway rated, install per NEC®; Environmental Air-Handling Space Installation per NEC® 300.22(C).

(9) Factory installed with integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens).

IES-format photometry for luminaire under emergency operation available. Battery option increases total height by 1 inch. (10) Used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided by others). Devices are universal voltage (UNV). 347 not available. (11) EL10WSD not available with 347V. (12) UEL10WSD not available with 347V. (C) Consult WaveLinx Low-Voltage or DLVP system pages for additional details and compatibility.

Driver Type Number of Drivers Integrated Sensing Systems Packaging Accessories

Driver Type Number of Drivers Integrated Sensing Systems (15) Packaging Accessories (order separately)

CD=0-10V Dimming Driver (1%-100% Dimming) WN=WaveLinx Wireless Fixture, No Sensor. (A), (G), (H)

5LTD=Fifth Light DALI Driver (5%-100% Dimming) (E)

5LTHD=Fifth Light Dimming Driver (1%-100% Dimming) (E)

LV=Low-voltage System Dimming Driver (0%-100% Dimming) (C)

SD=Step Dimming Driver (50%-100% Dimming) LH=Lutron HiLume (LDE1 series) 1%-100% EcoSystem Driver with Soft-on…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .