New_Const_Permit_8616_Baxter_Rd_SRCDS.pdf

PDF 3 MB Posted

Attached to
City Hall Wind Mitigation
Solicitation number
26-008
Issued by
Santa Rosa County, Mount Carmel CDP, Florida

About this file

This document is a Florida Department of Environmental Protection (FDEP) Onsite Sewage Treatment and Disposal System (OSTDS) Construction Permit issued for new system installation at 8616 Baxter Road, Milton, Florida 32583. The permit authorizes the design and construction of a new 900-gallon septic tank system with a 375-square-foot drainfield to replace an existing uncertified septic tank. The system is sized for a three-bedroom residential property with a maximum occupancy of six persons and an estimated daily flow of 300 gallons per day. The system must be constructed in accordance with specifications and standards outlined in Section 381.0065, Florida Statutes, and Chapter 62-6, Florida Administrative Code, with all setback requirements maintained. The drainfield will be installed as a standard trench configuration, with the bottom of the drainfield positioned 72 inches below the benchmark reference point. The permit was issued on October 30, 2025, with an expiration date of April 30, 2027. The applicant, David Stokes, paid a permit fee of $55, with the application processed under Application No. AP4287897 and Permit No. 57-S0-5164837.

The system specifications were prepared by Charles F. Oker, a Private Site Evaluator, and approved by Brooke Proffitt, Environmental Specialist I with FDEP-DWRM. The permit requires abandonment of the existing uncertified septic tank in accordance with current regulations and mandates completion of all work prior to final inspection and approval. The applicant should note that departmental approval does not guarantee satisfactory performance for any specific period and that any changes to material facts underlying the permit may require amendment and potential voiding of the permit. Additionally, issuance of this permit does not exempt the applicant from compliance with other federal, state, or local permitting requirements for property development. Re-inspection fees will be charged for additional inspections beyond the final approval process.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATE OF FLORIDA

DEPARTMENT OF ENVIRONMENTAL PROTECTION

ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM (OSTDS)

CONSTRUCTION PERMIT

Permit No. 57-S0-5164837 Application No. AP4287897

Date Paid: 10/22/2025 Fee Paid: 55

Receipt No. 57-PID-9364566 Document No. PR4299582

Facility ID. 57-5164837 Type [ X ] New System [ ] Existing System Modification [ ] Repair [ ] Abandonment [ ] Temporary

Subtype [ ] Aerobic Treatment Unit [ ] Non-Innovative PBTS [ ] Innovative PBTS [ ] Innovative Non PBTS [ ] Holding Tank [ ] Other (describe)

Applicant: David Stokes

Property Address: 8616 Baxter Rd City Milton State FL Zip 32583

Lot: Block: Subdivision:

Property ID No. 16-1N-27-0000-00129-0000 [Section, Township, Range, Parcel Number, or Tax ID No.]

The system must be constructed in accordance with specifications and standards of Section 381.0065, F.S., and Chapter 62-6, F.A.C.

Department approval of system does not guarantee satisfactory performance for any specific period of time. Any change in material facts, which served as a basis for issuance of this permit, require the applicant to amend the permit application. Such amendments may result in voiding this permit. Issuance of this permit does not exempt the applicant from compliance with other federal, state, or local permitting required for development of this property.

SYSTEM DESIGN AND SPECIFICATIONS

Tank

900 Gallons / GPD capacity [ X ] Septic Tank [ ] Aerobic Treatment Unit [ ] Multi-chambered [ ] In series

Gallons / GPD capacity N/A [ ] Multi-chambered [ ] In series

Gallons Grease Interceptor capacity

Gallons Dosing Tank capacity gallons at doses per 24 hours doses per 24 hours

Drainfield 375 Square feet primary drainfield system

Square feet N/A system

System type [ X ] Standard [ ] Filled [ ] Mound [ ]

Configuration [ X ] Trench [ ] Bed [ ]

Location of benchmark/reference point Nail w/ metal cap and orange tape in tree

Elevation of proposed system site 42 [ X ] inches [ ] feet [ ] above [ X ] below benchmark/reference point

Bottom of drainfield to be 72 [ X ] inches [ ] feet [ ] above [ X ] below benchmark/reference point

Fill required 0 inches Excavation required inches

Other Abandon the existing uncertified septic tank in accordance with current regulations. Install a new 900 gal septic tank system with 375 sq ft drainfield.

Maintain all setbacks in accordance with FAC 62-6. The above must be completed prior to Final Inspection & Approval. A re-inspection fee will be charged for additional inspections. Department approval of the system does not guarantee satisfactory performance for any specific period of time. The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd.

Specifications by Charles F Oker Private Site Evaluator Printed Name Title Signature

Approved by Brooke Proffitt Environmental Specialist I FDEP-DWRM

Printed Name Title Office Signature

Date issued 10/30/2025 Expiration date 04/30/2027

DEP 4016 07/2025, Construction Permit and Inspection, Part 1 of 2 (Obsoletes all previous editions which may not be used) Incorporated: subsection 62-6.003(1), F.A.C. Page 1 of 3