New_Const_Permit_8616_Baxter_Rd_SRCDS.pdf
PDF 3 MB Posted
- Attached to
- City Hall Wind Mitigation
- Solicitation number
- 26-008
- Issued by
- Santa Rosa County, Mount Carmel CDP, Florida
About this file
This document is a Florida Department of Environmental Protection (FDEP) Onsite Sewage Treatment and Disposal System (OSTDS) Construction Permit issued for new system installation at 8616 Baxter Road, Milton, Florida 32583. The permit authorizes the design and construction of a new 900-gallon septic tank system with a 375-square-foot drainfield to replace an existing uncertified septic tank. The system is sized for a three-bedroom residential property with a maximum occupancy of six persons and an estimated daily flow of 300 gallons per day. The system must be constructed in accordance with specifications and standards outlined in Section 381.0065, Florida Statutes, and Chapter 62-6, Florida Administrative Code, with all setback requirements maintained. The drainfield will be installed as a standard trench configuration, with the bottom of the drainfield positioned 72 inches below the benchmark reference point. The permit was issued on October 30, 2025, with an expiration date of April 30, 2027. The applicant, David Stokes, paid a permit fee of $55, with the application processed under Application No. AP4287897 and Permit No. 57-S0-5164837.
The system specifications were prepared by Charles F. Oker, a Private Site Evaluator, and approved by Brooke Proffitt, Environmental Specialist I with FDEP-DWRM. The permit requires abandonment of the existing uncertified septic tank in accordance with current regulations and mandates completion of all work prior to final inspection and approval. The applicant should note that departmental approval does not guarantee satisfactory performance for any specific period and that any changes to material facts underlying the permit may require amendment and potential voiding of the permit. Additionally, issuance of this permit does not exempt the applicant from compliance with other federal, state, or local permitting requirements for property development. Re-inspection fees will be charged for additional inspections beyond the final approval process.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATE OF FLORIDA
DEPARTMENT OF ENVIRONMENTAL PROTECTION
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM (OSTDS)
CONSTRUCTION PERMIT
Permit No. 57-S0-5164837 Application No. AP4287897
Date Paid: 10/22/2025 Fee Paid: 55
Receipt No. 57-PID-9364566 Document No. PR4299582
Facility ID. 57-5164837 Type [ X ] New System [ ] Existing System Modification [ ] Repair [ ] Abandonment [ ] Temporary
Subtype [ ] Aerobic Treatment Unit [ ] Non-Innovative PBTS [ ] Innovative PBTS [ ] Innovative Non PBTS [ ] Holding Tank [ ] Other (describe)
Applicant: David Stokes
Property Address: 8616 Baxter Rd City Milton State FL Zip 32583
Lot: Block: Subdivision:
Property ID No. 16-1N-27-0000-00129-0000 [Section, Township, Range, Parcel Number, or Tax ID No.]
The system must be constructed in accordance with specifications and standards of Section 381.0065, F.S., and Chapter 62-6, F.A.C.
Department approval of system does not guarantee satisfactory performance for any specific period of time. Any change in material facts, which served as a basis for issuance of this permit, require the applicant to amend the permit application. Such amendments may result in voiding this permit. Issuance of this permit does not exempt the applicant from compliance with other federal, state, or local permitting required for development of this property.
SYSTEM DESIGN AND SPECIFICATIONS
Tank
900 Gallons / GPD capacity [ X ] Septic Tank [ ] Aerobic Treatment Unit [ ] Multi-chambered [ ] In series
Gallons / GPD capacity N/A [ ] Multi-chambered [ ] In series
Gallons Grease Interceptor capacity
Gallons Dosing Tank capacity gallons at doses per 24 hours doses per 24 hours
Drainfield 375 Square feet primary drainfield system
Square feet N/A system
System type [ X ] Standard [ ] Filled [ ] Mound [ ]
Configuration [ X ] Trench [ ] Bed [ ]
Location of benchmark/reference point Nail w/ metal cap and orange tape in tree
Elevation of proposed system site 42 [ X ] inches [ ] feet [ ] above [ X ] below benchmark/reference point
Bottom of drainfield to be 72 [ X ] inches [ ] feet [ ] above [ X ] below benchmark/reference point
Fill required 0 inches Excavation required inches
Other Abandon the existing uncertified septic tank in accordance with current regulations. Install a new 900 gal septic tank system with 375 sq ft drainfield.
Maintain all setbacks in accordance with FAC 62-6. The above must be completed prior to Final Inspection & Approval. A re-inspection fee will be charged for additional inspections. Department approval of the system does not guarantee satisfactory performance for any specific period of time. The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd.
Specifications by Charles F Oker Private Site Evaluator Printed Name Title Signature
Approved by Brooke Proffitt Environmental Specialist I FDEP-DWRM
Printed Name Title Office Signature
Date issued 10/30/2025 Expiration date 04/30/2027
DEP 4016 07/2025, Construction Permit and Inspection, Part 1 of 2 (Obsoletes all previous editions which may not be used) Incorporated: subsection 62-6.003(1), F.A.C. Page 1 of 3
Brooke Proffitt Approved
| download - 2025-10-30T142626.043.pdf |
| New Construction App_8616 Baxter Rd_Stokes_SRCDS.pdf |
File details come from the government source that posted it. Updated .