This document contains answers to questions regarding solicitation number N68335-19-R-0109 from the Department of the Navy Naval Air Systems Command Naval Air Warfare Center for an Aircraft Generator Test Stand (AGTS). The answers provide clarification that individual or combinations of repetitive pulsing loads listed in section 3.1.3.4 may be tested, the power factor for a 24KVA load is unity, loads listed in sections 3.1.3.5(a) through (c) may be tested together, and that section 3.1.3.5(d) refers to testing requirements for transformer rectifier units up to 200 amps rather than defining them as a type of DC load bank.
Amendment 0006
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_0008__AGTS.doc | DOC document | |
| Amendment_0007__AGTS.doc | DOC document | |
| Amendment_0005__AGTS.doc | DOC document | |
| Amendment_0004__AGTS.doc | DOC document | |
| Amendment_0003__AGTS.doc | DOC document | |
| Amendment_0002__AGTS.doc | DOC document | |
| Amendment_0001__AGTS.doc | DOC document | |
| N6833519R0109_AGTS.doc | DOC document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been added by full text:
AMENDMENT 0006
The following are questions that were received by this Agency and our answers:
Question 1: Reference SOW paragraph 3.4.12.4.4. All media must be supportable using DoN Application & DADMS approved software. This list of software shall be made available to the Contractor upon request.
Answer 1: Per CNATTINST 1554.1A, Para 4.8 Development Software: 4-8. Development Software.
All instructional products will be produced in an open architecture, non-proprietary environment and meet all Navy and Marine Corps specifications regarding SCORM conformance, NeL, and Navy Marine Corps Intranet (NMCI) Core Build compliance Contact DELTIS for the most update Core Build information. In addition, the courseware must be able to launch in both a networked and non-networked environment. Any software used to develop or sustain courseware shall be Department of the Navy Application and Database Management System and Naval Education and Training Command approved. Prior to ANY instructional project or product kick-off, the developing agency shall initiate contact with CNATT DELTIS for a current listing of approved development software.
Once the desired development software is agreed upon, contractors can use one or a combination of the approved tools. It is important to remember that while the use of Adobe Flash in lessons is generally acceptable, an entire lesson cannot be developed in Adobe Flash.
CNATT DELTIS POCs:
Denise Green
Instructional Systems Specialist Supervisor
850-452-8077
Denise.green@navy.mil
Kevin Nelms
Instructional Systems Specialist
850-452-8223
Kevin.b.nelms@navy.mil
If unable to attain from CNATT DELTIS, data can be provided at Logistics Guidance Conference (Post Award) by Tech Data Manager.
Question 2: Reference TMCR 4.6. The DTDs, and associated tag and attribute descriptions, which are XLM constructs, may be obtained from the requiring activity.
Answer 2: Data will be provided at Logistics Guidance Conference (Post Award) by Tech Data Manager.
Question 3: Repetitive Pulsing Loads in 3.1.3.4:
a. Para 3.1.3.4 has (a)(b)(c) sub items, will three sub items be tested at the same time or one sub item be tested at one time?
Answer 3 a: The items will be tested individually, all at once, or any combination thereof.
b. Para 3.1.3.4.a, what is the power factor for 24KVA load?
Answer 3b: Unity Power factor of 1.0 Question 4: DC Load Bank in 3.1.3.5:
a. It contains (a)(b)(c)(d) sub items, will they be tested at the same time?
Answer 4 a: There may be a possibility where items a, b, and c will be tested at the same time.
b. The sub item (b) and (c) are the same, is that a typo?
Answer 4 b: These items are the same on purpose. There may be tests that require these loads to be applied at the same time.
c. Please clarify item (d) “Transformer Rectifier Unit” as a type of DC Load Bank.
Answer 4 c: The Transformer Rectifier Unit is not a type of load in this case. When testing some Transformer Rectifier Units, a DC load of up to 200 Amps may be required.
(End of Summary of Changes)