This document is a section of a solicitation for FY22 Site Fire Suppression Improvements at the NSA Mechanicsburg, PA facility, prepared by Fisher Engineering on 11/14/23. The document details specific safety and personnel requirements for the project, focusing on Site Safety and Health Officer (SSHO) responsibilities and Competent Person qualifications. Key requirements include:
The SSHO cannot serve as the Quality Control Manager or Superintendent and must ensure an equally-qualified alternate is available if off-site for over 24 hours. Competent Persons are required for high-risk activities including confined space entry, cranes and rigging, excavation, fall protection, and electrical work. These individuals must be designated in writing, meet specific activity requirements, and be on-site when relevant hazardous work is performed. Additionally, qualified trainers for the 40-hour contract safety awareness course must possess comprehensive knowledge of safety standards, electrical work, lockout/tagout procedures, fall protection, and other critical safety domains.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FY22 SITE FIRE SUPPRESSION IMPROVEMENTS (FINAL SUBMISSION) 1654727
NSA MECHANICSBURG, PA FISHER ENGINEERING (11/14/23)
associated sub-paragraphs.
If the SSHO is off-site for a period longer than 24 hours, an equally-qualified alternate SSHO must be provided and must fulfill the same roles and responsibilities as the primary SSHO. When the SSHO is temporarily (up to 24 hours) off-site, a Designated Representative (DR), as identified in the AHA may be used in lieu of an Alternate SSHO, and must be on the project site at all times when work is being performed.
Note that the DR is a collateral duty safety position, with safety duties in addition to their full time occupation.
1.7.1.1.1 Additional Site Safety and Health Officer (SSHO) Requirements and Duties
The SSHO may not serve as the Quality Control Manager , or as the Superintendent.
1.7.1.2 Competent Person Qualifications
Provide Competent Persons in accordance with EM 385-1-1 , Appendix Q and herein. Competent Persons for high risk activities include confined space, cranes and rigging, excavation/trenching, fall protection, and electrical work. The CP for these activities must be designated in writing, and meet the requirements for the specific activity (i.e.
competent person, fall protection).
The Competent Person identified in the Contractor's Safety and Health Program and accepted Accident Prevention Plan, must be on-site at all times when the work that presents the hazards associated with their professional expertise is being performed. Provide the credentials of the Competent Persons(s) to the Contracting Officer for information in consultation with the Safety Office.
1.7.1.2.1 Competent Person for Confined Space Entry
Provide a Confined Space (CP) Competent Person who meets the requirements of EM 385-1-1 , Appendix Q, and herein. The CP for Confined Space Entry must supervise the entry into each confined space in accordance with EM 385-1-1 , Section 34.
1.7.1.2.2 Competent Person for Scaffolding
Provide a Competent Person for Scaffolding who meets the requirements of EM 385-1-1 , Section 22.B.02 and herein.
1.7.1.2.3 Competent Person for Fall Protection
Provide a Competent Person for Fall Protection who meets the requirements of EM 385-1-1 , Section 21.C.04, 21.B.03, and herein.
1.7.1.3 Qualified Trainer Requirements
Individuals qualified to instruct the 40 hour contract safety awareness course, or portions thereof, must meet the definition of a Competent Person Trainer, and, at a minimum, possess a working knowledge of the following subject areas: EM 385-1-1 , Electrical Standards, Lockout/Tagout, Fall Protection, Confined Space Entry for Construction;
Excavation, Trenching and Soil Mechanics, and Scaffolds in accordance with 29 CFR 1926.450 , Subpart L.
SECTION 01 35 26 Page 10