ATTACHMENT B - 1736577_DWG.pdf

PDF 2 MB Posted

Attached to
DESIGN-BID-BUILD, X-132 CORRECT NETWORK INFRASTRUCTURE DEFICIENCIES, NAVAL STATION NORFOLK, NORFOLK, VIRGINIA
Solicitation number
N4008524R2770
Issued by

About this file

This document is a set of architectural and electrical drawings for the "CORRECT NETWORK INFRASTRUCTURE DEFICIENCIES" project at the Naval Station Norfolk in Virginia.

The key details are:

  • The project involves correcting network infrastructure deficiencies in Building X-132 at the Naval Station Norfolk.
  • The work includes demolition and new construction in multiple areas of the first floor, including renovations to offices, conference rooms, halls, and other spaces.
  • Electrical work includes power distribution, lighting, and security systems, with demolition and new installations.
  • The construction contract is a Design-Bid-Build, Firm Fixed Price Multiple Award Construction Contract, limited to specific 8(a) contractors.
  • The procuring agency is the Department of the Navy Naval Facilities Engineering Command.
  • The project is scheduled for completion on June 28, 2024.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NAVAL STATION - NORFOLK, VIRGINIA

NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND MID-ATLANTIC

PUBLIC WORKS DEPARTMENT

FACILITIES ENGINEERING AND ACQUISITION DIVISION

NORFOLK, VIRGINIA

06/28/2024

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 8/

:0

3:

P M

C :\R ev it2

1L oc al

M od el s\

X1

-1

-A -R

_h az el

.e cl ar in al .rv t

GI001

X1

CO

VE

R

SH

EE

T

HME

12,911,543

HME DAS

06/28/2024

JECC - MICHAEL FREDERICK

CO

RR

EC

T

NE

TW

O

RK

IN

FR

AS

TR

UC

TU

RE

D

EF

IC

IE

NC

IE

S

HAZEL ECLARINAL, R.A.

1736577

N/A

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

JOHN MILLER, P.E.

AMANDA PILLO, R.A.

M

ID

LA

N

T -P

W D

N O

R

FO

LK

G I0

X132

CORRECT NETWORK INFRASTRUCTURE DEFICIENCIES

SY

M

DE

S C

RI

PT

I O N

DA

TE

AP

PR

WILLOUGHBY BAY

NAVAL SUPPORT

ACTIVITY

U.S. NAVAL STATION

SEWELLS POINT

NORFOLK

U.S. NAVAL

AIR STATION

CHESAPEAKE BAY

LITTLE CREEK

U.S. NAVAL

AMPHIBIOUS BASE

VA BEACH

OCEANA

NAVAL AIR

STATION

CHESAPEAKE

SOUTHERN BRANCH

EASTERN BRANCH

ST. JULIEN'S CREEK

U.S. NAVAL ANNEX

ELIZABETH RIVER

58 460

PORTSMOUTH

U.S. ARMY CRANEY

ISLAND DISPOSAL AREA

NANSEMOND RIVER

WESTERN BRANCH

CRANEY

ISLAND NAVY

DEPOT

PROJECT SITE

NORTH

A1 A-201

EXTERIOR ELEVATION

INDICATOR

ELEVATION NUMBER

DIRECTION OF VIEW

SHEET WHERE DRAWN

A-901 PHOTOGRAPH

INDICATOR

PHOTOGRAPH NUMBER

SHEET WHERE SHOWN

A1

ROOM

101 ROOM IDENTIFIER

DETAIL NUMBER

SHEET WHERE DRAWN

DETAIL TAG

ROOM NAME

ROOM NUMBER

A-401 INTERIOR ELEVATION

INDICATOR

INTERIOR ELEVATION NUMBER

SHEET WHERE DRAWN

DETAIL NUMBER

SHEET REFERENCED FROM

WALL / PARTIAL BUILDING

SECTION INDICATOR

GENERAL PROJECT SYMBOLS

KEYNOTE INDICATOR

KEYNOTE NUMBER

TRUE NORTH

A-101

A1

A1

A1

A1

GRAPHIC SCALE

GRAPHIC SCALE

0 4' 8' 16'

VIEW NAME

SCALE: 1/8" = 1'-0"A1 (A-101)

0 4' 8' 16'

PLAN

NORTH

VIEW NAME

SCALE: 1/8" = 1'-0"

PLAN TITLE

A1 A-301

SECTION NUMBER

SHEET WHERE DRAWN

BUILDING

SECTION

INDICATOR

A1 A-301

A1

A-301

BUILDING

SECTION NUMBER

SHEET WHERE DRAWN

PIER 11

PIER 10

PIER 9

PROJECT SITE

BUNKER HILL

DILLINGHAM BLVD

BU

NK

ER

H

ILL

DE

CA

TU

R

AV

E

105TH ST

RO

DG

ER

S

AV

E

HULL ST

PREBLE ST

VIRGINIA AVE

MARYLAND AVE

DILLINGHAM BLVD

MASSEY

HUGHES DR

MARYLAND AVE

NORTH

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 8/

:0

3:

P M

C :\R ev it2

1L oc al

M od el s\

X1

-1

-A -R

_h az el

.e cl ar in al .rv t

GI002

X1

LI

ST

O F

SH

EE

TS

, G

EN

ER

AL

P

RO

JE

CT

N

O

TE

S

AN

D

SY

M

BO

LS

HME

12,911,544

HME DAS

06/28/2024

JECC - MICHAEL FREDERICK

CO

RR

EC

T

NE

TW

O

RK

IN

FR

AS

TR

UC

TU

RE

D

EF

IC

IE

NC

IE

S

HAZEL ECLARINAL, R.A.

1736577

N/A

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

JOHN MILLER, P.E.

AMANDA PILLO, R.A.

M

ID

LA

N

T -P

W D

N O

R

FO

LK

G I0

LIST OF SHEETS

SHEET NO.

NAVFAC DWG. NO. SHEET TITLENO. SHEET

GENERAL

1 GI001 12,911,543 COVER SHEET

2 GI002 12,911,544 LIST OF SHEETS, GENERAL PROJECT NOTES AND SYMBOLS

ARCHITECTURE

3 A-001 12,911,545 ARCHITECTURAL ABBREVIATIONS, NOTES, SYMBOLS, AND OVERALL PLAN

4 AD101 12,911,546 FIRST FLOOR PLAN - PART D/E - DEMOLITION

5 AD102 12,911,547 FIRST FLOOR PLAN - AREA C - DEMOLITION

6 AE101 12,911,548 FIRST FLOOR PLAN - PART D/E - NEW WORK

7 AE102 12,911,549 FIRST FLOOR PLAN - PART C - NEW WORK

8 AE601 12,911,550 DOOR SCHEDULE AND DETAILS

9 AE602 12,911,551 WINDOW ELEVATIONS & DETAILS

ELECTRICAL

10 E-001 12,911,552 ELECTRICAL SYMBOLS, LEGEND, ABBREVIATIONS, AND NOTES

11 ED101 12,911,553 FLOOR PLAN - DEMOLITION

12 EP101 12,911,554 FLOOR PLAN - POWER

13 EP501 12,911,555 ELECTRICAL DETAILS

VICINITY MAP

GENERAL PROJECT NOTES GOVERNING REGULATIONS

LOCATION MAP

BUILDING CODE:

UNIFIED FACILITIES CRITERIA (UFC) 1-200-01 DoD BUILDING CODE (CHANGE 1, 01 OCT. 2020)

INTERNATIONAL BUILDING CODE (IBC) 2021

ACCESSIBILITY CODE:

ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES, ICC A117.1 (2017)

ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS (2015)

ELECTRICAL CODE:

NFPA 70, NATIONAL ELECTRIC CODE (NEC) 2020

1 WHERE EXISTING CONSTRUCTION IS DAMAGED BY CONSTRUCTION

REQUIRED BY THESE DOCUMENTS. REPAIR THE DAMAGED ITEM(S) WITH

MATERIALS TO MATCH THE ADJACENT MATERIAL, TEXTURE AND COLOR.

2 FIELD VERIFY EXISTING DIMENSIONS, PRIOR TO ORDERING MATERIALS OR

BEGINNING DEMOLITION.

3 ALL ITEMS NOT SHOWING AS "EXISTING" MUST BE PROVIDED AND

INSTALLED UNDER THE REQUIREMENTS OF THIS CONTRACT.

4 COORDINATE LAY DOWN AREA WITH THE CONTRACTING OFFICER PRIOR TO

THE PRECONSTRUCTION MEETING. THE ALLOWABLE AREA SIZE MUST BE

ESTABLISHED BY THE CONTRACTING OFFICER.

5 MANUFACTURER'S TRADE NAMES LISTED ARE NOT INTENDED TO BE

PROPRIETARY. PRODUCTS OF OTHER MANUFACTURERS WILL BE

ACCEPTABLE PROVIDED THEY MATCH THE COLOR, FINISHES, TEXTURES

AND PATTERNS OF THE MANUFACTURER LISTED, AND MEET THE TECHNICAL

REQUIREMENTS OF THE SPECIFICATIONS.

6 OBSERVE AND MAINTAIN BUILDING AND COMPOUND SECURITY

REQUIREMENTS AS DIRECTED BY THE CONTRACTING OFFICER.

7 CONSTRUCTION WILL BE ACCOMPLISHED IN AND AROUND AREAS WHICH

WILL REMAIN OPERATIONAL. AVOID INTERFERENCE WITH THE OPERATIONAL

WORK ROUTINE.

8 ALL SUBMITTALS REQUIRED BY THESE DRAWINGS OR SPECIFICATIONS

MUST BE SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL TO

COMMENCEMENT OF RELATED WORK.

9 STUDY AND COMPARE THE CONTRACT DOCUMENTS WITH EACH OTHER,

AND AT ONCE, REPORT TO THE CONTRACTING OFFICER ANY ERRORS,

INCONSISTENCIES, OR OMISSIONS DISCOVERED. ANY CONSTRUCTION

ACTIVITY PERFORMED KNOWING IT INVOLVES A RECOGNIZED ERROR,

INCONSISTENCY OR OMISSION IN THE CONTRACT DOCUMENTS WITHOUT

SUCH NOTICE TO THE CONTRACTING OFFICER, THE CONTRACTOR WILL

ASSUME RESPONSIBILITY FOR SUCH PERFORMANCE AND WILL BEAR THE

AMOUNT OF THE COST OF THE CONSTRUCTION.

10 ENTRY INTO BUILDING X-132 IS PROHIBITED WITHOUT AN APPROVED

ESCORT. PRIOR TO PERFORMING ANY WORK, ALL PERSONNEL MUST HAVE

APPROVED ACCESS FROM THE COMMAND. ACCESS TO OTHER AREAS OF

THE BUILDING OUTSIDE THE AREA OF WORK ARE PROHIBITED WITHOUT AN

APPROVED ESCORT.

SY

M

DE

S C

RI

PT

I O N

DA

TE

DOOR NUMBER

(REFER TO DOOR SCHEDULE)

DOOR TAG

ARCHITECTURAL SYMBOLS

REFER TO SHEET GI002 FOR

ADDITIONAL PROJECT SYMBOLS

MATERIALS LEGEND

CONCRETE MASONRY UNIT

CAST-IN-PLACE CONCRETE

STEEL

BATT/LOOSE FILL INSULATION

RIGID INSULATION

WOOD BLOCKING

CMU - PAINTED

SECTION

ELEVATION

CMU - PAINTED - ACCENT

GLAZING

SPANDREL GLAZING / STEEL PANEL

ALUMINUM

BRICK

GYPSUM BOARD

PLYWOOD

SAND / MORTAR / PLASTER

ACOUSTICAL TILE CEILING

CERAMIC TILE

FINISHED WOOD

MAIN ENTRANCE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 8/

:0

3:

P M

C :\R ev it2

1L oc al

M od el s\

X1

-1

-A -R

_h az el

.e cl ar in al .rv t

A-001

X1

AR

CH

IT

EC

TU

RA

L

AB

BR

EV

IA

TI

O

NS

, N O

TE

S, S

YM

BO

LS

, A

ND

O

VE

RA

LL

P

LA

N

HME

12,911,545

HME DAS

06/28/2024

JECC - MICHAEL FREDERICK

CO

RR

EC

T

NE

TW

O

RK

IN

FR

AS

TR

UC

TU

RE

D

EF

IC

IE

NC

IE

S

HAZEL ECLARINAL, R.A.

1736577

N/A

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

JOHN MILLER, P.E.

AMANDA PILLO, R.A.

M

ID

LA

N

T -P

W D

N O

R

FO

LK

A-

SIM SIMILAR

SPEC SPECIFICATION

SQ SQUARE

STD STANDARD

STOR STORAGE

TEL TELEPHONE

THRU THROUGH

TOS TOP OF SLAB / STEEL

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

VB VINYL BASE

VCT VINYL COMPOSITION TILE

VEST VESTIBULE

VS VENT STACK

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

W WASTE / WATT / WEST / WIDE

W/ WITH

W/O WITHOUT

WC WATER CLOSET / WALL COVERING

WD WOOD

WH WATER HEATER

WT WEIGHT

GL GLASS / GROUND LEVEL

GYP GYPSUM

H HIGH

HB HOSE BIB

HDW HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HT HEIGHT

INSUL INSULATION / INSULATED

INT INTERIOR

JAN JANITOR CLOSET

LB POUND

MAX MAXIMUM

MECH MECHANICAL

MFG MANUFACTURING

MIN MINIMUM / MINUTE

MISC MISCELLANEOUS

MO MASONRY OPENING / MOTOR OPERATED

N NORTH

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OC ON CENTER

OPH OPPOSITE HAND

OPP OPPOSITE

PCT PERCENT

PEJ PREMOLDED EXPANSION JOINT

PRELIM PRELIMINARY

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT

R RADUIS / RISER

RB RESILIENT BASE

RD ROOF DRAIN / ROAD

REFR REFRIGERATION

REINF REINFORCE

REQD REQUIRED

REV REVISION

RF RESILIENT FLOORING

RL ROOF LEADER

RM ROOM

RND ROUND

RO ROUGH OPENING

RS ROUGH SAWN

RT RIGHT

S SOUTH

SECT SECTION

SF SQUARE FOOT

ACT ACOUSTICAL CEILING TILE

ALUM ALUMINUM

ARCH ARCHITECT

BD BOARD

BLDG BUILDING

CJ CONTROL / CONSTRUCTION JOINT

CLG CEILING

CLG REG CEILING REGISTER

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

COL COLUMN

CONC CONCRETE

CONT CONTINUE / CONTINUOUS

CORR CORRIDOR

CPT CARPET / COMMON PATH OF TRAVEL

CT CERAMIC TILE

CTR CENTER

D DEPTH / DEEP

DEMO DEMOLITION

DIA DIAMETER

DIM DIMENSION

DS DOWNSPOUT

DW DISHWASHER

DWG DRAWING

E EAST

EA EACH

EJ EXPANSION JOINT

ELEC ELECTRIC / ELECTRICAL

EQ EQUAL

EQUIP EQUIPMENT

EW EACH WAY

EXIST EXISTING

EXP EXPANSION / EXPOSED / EXPAND

EXT EXTERIOR

FD FLOOR DRAIN

FF FINISH FACE

FHC FIRE HOUSE CABINET

FIN FLR FINISHED FLOOR

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF STUB / FACE OF SLAB

FR FRAME / FIRE RATING / FIRE RESISTANT

FT FOOT, FEET

FTG FOOTING

GA GAUGE

GALV GALVANIZED

GFCI GOVERNMENT FURNISHED

CONTRACTOR INSTALLED

0 15' 30' 60'

PLAN

NORTH

SCALE: 1" = 30'-0"

OVERALL FIRST FLOOR PLAN

GENERAL ARCHITECTURAL NOTESARCHITECTURAL ABBREVIATIONS

1 ALL ITEMS INDICATED TO BE REMOVED MUST BE DISPOSED OF OFF-SITE

UNLESS OTHERWISE NOTED.

2 ALL MATERIALS MUST BE NEW AND PROVIDED BY THE CONTRACTOR

UNLESS SPECIFICALLY NOTED AS EXISTING OR AS PROVIDED BY THE

GOVERNMENT.

3 ALL WOOD BLOCKING AND MISCELLANEOUS STEEL SHOWN IN DETAILS AND

SECTIONS MUST BE CONTINUOUS UNLESS SPECIFICALLY NOTED

OTHERWISE.

4 VERIFY ALL FIELD CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING

WITH THE WORK. DIMENSIONS FOR EXISTING WORK ARE INDICATED AS "±".

ALL DISCREPANCIES MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF

THE CONTRACTING OFFICER IN WRITING.

5 REFER TO FIRE PROTECTION, MECHANICAL, ELECTRICAL, AND

TELECOMMUNICATION DRAWINGS FOR ADDITIONAL INFORMATION.

6 DIMENSIONS INDICATED FOR NEW WORK ARE TO FACE OF STUD, FACE OF

MASONRY OR FACE OF EXISTING SURFACES UNLESS OTHERWISE NOTED.

7 REFER TO SHEET GI002 FOR ADDITIONAL GENERAL PROJECT NOTES.

DCA B E

KEY PLAN

SY

M

DE

S C

RI

PT

I O N

DA

TE

DN

DN

25 26 27 28 29 30 31 32 33 34

A

B

C

D

E

F

G

OFFICE

OFFICE

OFFICE

TOILET

STAIR

HALL

LOUNGE

VESTIBULE

OFFICE

CONF ROOM

MEN

OFFICE

OFFICE

OFFICE

WOMEN

OFFICE

SECURITY

VESTIBULE

PERSONNEL

STORAGE

107B

SPRINKLER

STAIR

QUARTERDECK

STORAGE

JANITOR

VESTIBULE

ELEC

CLOSET

CLOSET

HALL

OFFICE

138A

OFFICE

138B

OFFICE

138C

SERVER ROOM

CRYPTO

OFFICE

FUSION CELL

CONF ROOM

OPEN OFFICE

OFFICE

LOBBY

OFFICE

OFFICE

CONF ROOM

SECURITY

OPEN OFFICE

SPRINKLER

AT

OPEN OFFICE

SPECAT

SCIF COMM

CRYPTO

FUSION CELL

4'-0" 3'-0"

3333333

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 8/

:0

3:

P M

C :\R ev it2

1L oc al

M od el s\

X1

-1

-A -R

_h az el

.e cl ar in al .rv t

AD101

X1

FI

RS

T

FL

O O

R

PL

AN

PA

RT

D /E

DE

M O

LI

TI

O N

HME

12,911,546

HME KES

06/28/2024

JECC - MICHAEL FREDERICK

CO

RR

EC

T

NE

TW

O

RK

IN

FR

AS

TR

UC

TU

RE

D

EF

IC

IE

NC

IE

S

HAZEL ECLARINAL, R.A.

1736577

N/A

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

JOHN MILLER, P.E.

AMANDA PILLO, R.A.

M

ID

LA

N

T -P

W D

N O

R

FO

LK

AD

GENERAL SHEET NOTES

KEYNOTES

1 REMOVE DOOR(S), FRAME, AND HARDWARE COMPLETE

2 REMOVE WINDOW AND FRAME COMPLETE

3 REMOVE WINDOW BLINDS COMPLETE

DCA B E

KEY PLAN

1 REFER TO SHEET A-001 FOR ADDITIONAL GENERAL ARCHITECTURAL NOTES.

2 THE WORK INCLUDES THE DEMOLITION AND REMOVAL OF ALL

CONSTRUCTION INDICATED, NOTED, OR NECESSARY TO ACCOMPLISH THE

WORK AS INDICATED OR SPECIFIED. IT IS THE GENERAL INTENT OF THE

DEMOLITION WORK TO COMPLETELY REMOVE ALL ITEMS OF EXISTING

CONSTRUCTION, WHERE NOTED OR INDICATED ON THE DRAWINGS,

INCLUDING, BUT NOT LIMITED TO: ANCHORS, FASTENERS, BRACKETS, CLIPS,

RODS, HANGERS, AND SUPPORTS COMPLETE.

3 EXISTING DIMENSIONS ARE BASED ON EXISTING DRAWINGS AND FIELD

WORK. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO

PERFORMING ANY WORK. BRING ANY DISCREPANCIES TO THE ATTENTION

OF THE CONTRACTING OFFICER PRIOR TO PERFORMING ANY WORK.

4 ALL INTERIOR FINISHED SURFACES WHICH ARE DAMAGED WHILE

PERFORMING WORK UNDER THIS CONTRACT MUST BE PATCHED AND/OR

REPLACED AND FINISHED TO MATCH ADJACENT AREAS AT NO COST TO THE

GOVERNMENT.

5 DEMOLITION OF INTERIOR DESIGN, FIRE PROTECTION, PLUMBING,

MECHANICAL, ELECTRICAL, AND TELECOMMUNICATION ITEMS INDICATED ON

THE ARCHITECTURAL DRAWINGS IS NOT INTENDED TO INCLUDE ALL

NECESSARY DEMOLITION WORK FOR THESE ITEMS. REFER TO INTERIOR

DESIGN, FIRE PROTECTION, PLUMBING, MECHANICAL, ELECTRICAL, AND

TELECOMMUNICATION DRAWINGS FOR ADDITIONAL INFORMATION.

6 DEMOLITION PLANS, INCLUDING EQUIPMENT SHOWN, IS A VISUAL

REPRESENTATION OF THE CONDITION OF THE BUILDING AT THE TIME FIELD

WORK WAS CONDUCTED.

0 4' 8' 16'

PLAN

NORTH

SCALE: 1/8" = 1'-0"

FIRST FLOOR PLAN - PART D/E - DEMOLITION

SY

M

DE

S C

RI

PT

I O N

DA

TE

DNDNDN

DN

DN

16 17 18 19 20 21 22 23 24 25

A

B

C

D

E

F

G

HALL

IT CUSTOMER SERVICE

SERVER ROOM

JOC

TELEPHONE

STAIR

VESTIBULE

HALL

STAIR

HALL

OFFICE

OFFICE

AV EQUIP

HALL

SPRINKLER

UPS

EQUIP

MEN

VESTIBULE

WOMEN

HALL

BREAK ROOM

HALL

VTC

OPEN OFFICE

CPG

ELECTRICAL

MECH

STO OFFICE

151B

TRAINING

182 CONFERENCE

STORAGE

MECH

MECH

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 8/

:0

3:

P M

C :\R ev it2

1L oc al

M od el s\

X1

-1

-A -R

_h az el

.e cl ar in al .rv t

AD102

X1

FI

RS

T

FL

O O

R

PL

AN

AR

EA

C

DE

M

O

LI

TI

O

N

HME

12,911,547

HME KES

06/28/2024

JECC - MICHAEL FREDERICK

CO

RR

EC

T

NE

TW

O

RK

IN

FR

AS

TR

UC

TU

RE

D

EF

IC

IE

NC

IE

S

HAZEL ECLARINAL, R.A.

1736577

N/A

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

JOHN MILLER, P.E.

AMANDA PILLO, R.A.

M

ID

LA

N

T -P

W D

N O

R

FO

LK

AD

0 4' 8' 16'

PLAN

NORTH

SCALE: 1/8" = 1'-0"

FIRST FLOOR PLAN - PART C - DEMOLITION

GENERAL SHEET NOTES

KEYNOTES

DCA B E

KEY PLAN

1 REFER TO SHEET A-001 FOR ADDITIONAL GENERAL ARCHITECTURAL NOTES.

2 THE WORK INCLUDES THE DEMOLITION AND REMOVAL OF ALL

CONSTRUCTION INDICATED, NOTED, OR NECESSARY TO ACCOMPLISH THE

WORK AS INDICATED OR SPECIFIED. IT IS THE GENERAL INTENT OF THE

DEMOLITION WORK TO COMPLETELY REMOVE ALL ITEMS OF EXISTING

CONSTRUCTION, WHERE NOTED OR INDICATED ON THE DRAWINGS,

INCLUDING, BUT NOT LIMITED TO: ANCHORS, FASTENERS, BRACKETS, CLIPS,

RODS, HANGERS, AND SUPPORTS COMPLETE.

3 EXISTING DIMENSIONS ARE BASED ON EXISTING DRAWINGS AND FIELD

WORK. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO

PERFORMING ANY WORK. BRING ANY DISCREPANCIES TO THE ATTENTION

OF THE CONTRACTING OFFICER PRIOR TO PERFORMING ANY WORK.

4 ALL INTERIOR FINISHED SURFACES WHICH ARE DAMAGED WHILE

PERFORMING WORK UNDER THIS CONTRACT MUST BE PATCHED AND/OR

REPLACED AND FINISHED TO MATCH ADJACENT AREAS AT NO COST TO THE

GOVERNMENT.

5 DEMOLITION OF INTERIOR DESIGN, FIRE PROTECTION, PLUMBING,

MECHANICAL, ELECTRICAL, AND TELECOMMUNICATION ITEMS INDICATED ON

THE ARCHITECTURAL DRAWINGS IS NOT INTENDED TO INCLUDE ALL

NECESSARY DEMOLITION WORK FOR THESE ITEMS. REFER TO INTERIOR

DESIGN, FIRE PROTECTION, PLUMBING, MECHANICAL, ELECTRICAL, AND

TELECOMMUNICATION DRAWINGS FOR ADDITIONAL INFORMATION.

6 DEMOLITION PLANS, INCLUDING EQUIPMENT SHOWN, IS A VISUAL

REPRESENTATION OF THE CONDITION OF THE BUILDING AT THE TIME FIELD

WORK WAS CONDUCTED.

1 REMOVE DOOR(S), FRAME, AND HARDWARE COMPLETE

SY

M

DE

S C

RI

PT

I O N

DA

TE

DN

25 26 27 28 29 30 31 32 33 34

A

B

C

D

E

F

OFFICE

OFFICE

OFFICE

TOILET

STAIR

HALL

LOUNGE

VESTIBULE

OFFICE

CONF ROOM

MEN

OFFICE

OFFICE

OFFICE

WOMEN

OFFICE

SECURITY

VESTIBULE

PERSONNEL

STORAGE

107B

SPRINKLER

STAIR

QUARTERDECK

STORAGE

JANITOR

VESTIBULE

ELEC

CLOSET

CLOSET

HALL

OFFICE

138A

OFFICE

138B

OFFICE

138C

SERVER ROOM

CRYPTO

OFFICE

FUSION CELL

CONF ROOM

OPEN OFFICE

OFFICE

LOBBY

OFFICE

OFFICE

CONF ROOM

SECURITY

OPEN OFFICE

SPRINKLER

AT

OPEN OFFICE

SPECAT

SCIF COMM

OPEN OFFICE

106B

122B

AE602

C5

1111111

11'-11" 7'-11" 12'-6 1/2"

F G A B

B

C

C1

A

A

C

C

B

9'-5"

9'- 5"

3'- 4 1

/4" 3'-

4 1 /4"

'-1

0 1 /4"

3'- 2 9

/16

6'- 5 1

/8"

3'- 2 9

/16

3'- 4 1

/4" 3'-

4 1 /4"

9'- 8 1

/4"

9'-8 1/4"

BAAGFFFF

12'-10 1/4"12'-10 1/4"7'-11"11'-11"11'-11"11'-11"11'-11"

2 2 2 2

22222222

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 8/

:0

3:

P M

C :\R ev it2

1L oc al

M od el s\

X1

-1

-A -R

_h az el

.e cl ar in al .rv t

AE101

X1

FI

RS

T

FL

O O

R

PL

AN

PA

RT

D /E

NE

W W

O

RK

HME

12,911,548

HME KES

06/28/2024

JECC - MICHAEL FREDERICK

CO

RR

EC

T

NE

TW

O

RK

IN

FR

AS

TR

UC

TU

RE

D

EF

IC

IE

NC

IE

S

HAZEL ECLARINAL, R.A.

1736577

N/A

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

JOHN MILLER, P.E.

AMANDA PILLO, R.A.

M

ID

LA

N

T -P

W D

N O

R

FO

LK

AE

GENERAL SHEET NOTES

KEYNOTES

DCA B E

KEY PLAN

1 ROLLER SHADE; PATCH AND REPAIR HOLES WHERE WINDOW BLINDS ARE

REMOVED

2 EXTERIOR WINDOW FILM APPLIED TO EXISTING WINDOW GLAZING

3 BULLET RESISTANT WINDOW ASSEMBLY

1 REFER TO SHEET GI002 FOR ADDITIONAL GENERAL PROJECT NOTES.

2 REFER TO ELECTRICAL AND TELECOMMUNICATION DRAWINGS FOR

ADDITIONAL INFORMATION.

3 DIMENSIONS ARE FROM FACE OF EXISTING SURFACE AND COLUMN

CENTERLINE, UNLESS OTHERWISE NOTED.

4 ALL INTERIOR FINISHED SURFACES WHICH ARE DAMAGED WHILE

PERFORMING WORK UNDER THIS CONTRACT MUST BE PATCHED AND/OR

REPLACED AND FINISHED TO MATCH ADJACENT AREAS AT NO COST TO THE

GOVERNMENT.

0 4' 8' 16'

PLAN

NORTH

SCALE: 1/8" = 1'-0"

PARTIAL FIRST FLOOR PLAN

SY

M

DE

S C

RI

PT

I O N

DA

TE

DNDN

DN

DN

DN

16 17 18 19 20 21 22 23 24 25

A

B

C

D

E

F

G

HALL

IT CUSTOMER SERVICE

SERVER ROOM

OFFICE

OFFICE

AV EQUIP

HALL

SPRINKLER

UPS

EQUIP

MEN

VESTIBULE

WOMEN

HALL

BREAK ROOM

HALL

VTC

OPEN OFFICE

JOC

TELEPHONE

CPG

STAIR

VESTIBULE

HALL

ELECTRICAL

MECH

STAIR

STO OFFICE

151B

HALL

180B

180A

TRAINING

182 CONFERENCE

STORAGE

MECH

MECH

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 8/

:0

3:

P M

C :\R ev it2

1L oc al

M od el s\

X1

-1

-A -R

_h az el

.e cl ar in al .rv t

AE102

X1

FI

RS

T

FL

O O

R

PL

AN

PA

RT

C

NE

W

W O

RK

HME

12,911,549

HME KES

06/28/2024

JECC - MICHAEL FREDERICK

CO

RR

EC

T

NE

TW

O

RK

IN

FR

AS

TR

UC

TU

RE

D

EF

IC

IE

NC

IE

S

HAZEL ECLARINAL, R.A.

1736577

N/A

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

JOHN MILLER, P.E.

AMANDA PILLO, R.A.

M

ID

LA

N

T -P

W D

N O

R

FO

LK

AE

0 4' 8' 16'

PLAN

NORTH

SCALE: 1/8" = 1'-0"

PARTIAL FIRST FLOOR PLAN

GENERAL SHEET NOTES

KEYNOTES

DCA B E

KEY PLAN

1 REFER TO SHEET GI002 FOR ADDITIONAL GENERAL PROJECT NOTES.

2 REFER TO ELECTRICAL AND TELECOMMUNICATION DRAWINGS FOR

ADDITIONAL INFORMATION.

3 DIMENSIONS ARE FROM FACE OF EXISTING SURFACE AND COLUMN

CENTERLINE, UNLESS OTHERWISE NOTED.

4 ALL INTERIOR FINISHED SURFACES WHICH ARE DAMAGED WHILE

PERFORMING WORK UNDER THIS CONTRACT MUST BE PATCHED AND/OR

REPLACED AND FINISHED TO MATCH ADJACENT AREAS AT NO COST TO THE

GOVERNMENT.

SY

M

DE

S C

RI

PT

I O N

DA

TE

FLUSH PANEL

(PAIR)

A

FINISHED FLOOR

DOOR WIDTH

EQ EQ

DO

OR

H

EI

GH

T

FLUSH PANEL

(UNEVEN)

B

DOOR WIDTH

DO

OR

H

EI

GH

T

DOOR WIDTH

3'-0"

DO

OR

H

EI

GH

T

C

FLUSH PANEL

(SINGLE)

REFER TO DETAIL

FOR TYP HM FRAME PROFILE

F-3

HOLLOW METAL

KNOCK DOWN

2"

WIDTH

DOOR 2"

2"

DO

OR

H

EI

GH

T

/A5 AE601

RAISED ACCESS FLOOR

FINISHED FLOOR

F-1

HOLLOW METAL

KNOCK DOWN

2"

WIDTH

DOOR 2"

2"

DO

OR

H

EI

GH

T

REMOVABLE

HM MULLION

F-2

HOLLOW METAL

KNOCK DOWN

2"

WIDTH

DOOR 2"

2"

DO

OR

H

EI

GH

T

5/8

2"

VARIES

1 15/16" 1 9/16"

1/2" 1/16"

EXISTING

PARTITION - FIELD

VERIFY DIMENSION

PATCH AND REPAIR EXIST

PARTITION TO REMAIN

CONTINUOUS SEALANT,

BOTH SIDES

HOLLOW METAL FRAME AS

SCHEDULED2"

DOOR AS SCHEDULED

FIELD VERIFY

4 7/8" ±

PATCH AND REPAIR EXIST

PARTITION TO REMAIN

CONTINUOUS SEALANT, BOTH SIDES

HOLLOW METAL FRAME AS

SCHEDULED2"

DOOR AS SCHEDULED

STEEL STUD ANCHORS (3 PER JAMB)

FIELD VERIFY

4 7/8" ±

DOOR FRAME (BEYOND) - PAINT

AS SCHEDULED

DOOR AS SCHEDULED

1'- 4"

FI

EL

D

VE

RI

FY

ALUMINUM SADDLE FASTENED

TO EXIST WOOD BLOCKING

EXIST WOOD BLOCKING TO

REMAIN

EXIST PARTITION TO REMAIN;

PATCH AND REPAIR HOLES AND

SEAL AROUND PENETRATIONS

RAISED ACCESS FLOOR EXIST

TO REMAIN

RAISED ACCESS FLOOR EXIST

TO REMAIN

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 8/

:0

3:

P M

C :\R ev it2

1L oc al

M od el s\

X1

-1

-A -R

_h az el

.e cl ar in al .rv t

AE601

X1

DO

O

R

SC

HE

DU

LE

A

ND

D

ET

AI

LS

HME

12,911,550

HME KES

06/28/2024

JECC - MICHAEL FREDERICK

CO

RR

EC

T

NE

TW

O

RK

IN

FR

AS

TR

UC

TU

RE

D

EF

IC

IE

NC

IE

S

HAZEL ECLARINAL, R.A.

1736577

N/A

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

JOHN MILLER, P.E.

AMANDA PILLO, R.A.

M

ID

LA

N

T -P

W D

N O

R

FO

LK

AE

D

OO

R

NO

DOOR FRAME

FI

RE

R

AT

IN

G

H

AR

DW

AR

E S

ET

N O.

REMARKS TY

PE

SIZE

M

AT

ER

IA

L

TY

PE

M

AT

ER

IA

L

DETAILS ON THIS SHEET UON

W

ID

TH

H

EIG

HT

TH

IC

KN

ES

S

HEAD JAMB SILL

106B B 5'-0" 7'-0" 1 3/4" HM F-2 HM D3 C3 A3 -- 3 2

122B B 5'-0" 7'-0" 1 3/4" HM F-2 HM D3 C3 A3 -- 4 2

138 C 4'-0" 7'-0" 1 3/4" HM F-3 HM D3 C3 A3 -- 2 2

180A A 6'-0" 7'-0" 1 3/4" HM F-1 HM D3 C3 A3 -- 1 1, 2

180B A 6'-0" 7'-0" 1 3/4" HM F-1 HM D3 C3 A3 -- 1 1, 2

DOOR SCHEDULE

0 2' 4' 8'SCALE: 1/4" = 1'-0"

DOOR TYPESC4

0 2' 4' 8'SCALE: 1/4" = 1'-0"

FRAME TYPESB4

0 1" 2" 4"SCALE: 6" = 1'-0"

HM FRAME PROFILEA5

0 2" 4" 8"SCALE: 3" = 1'-0"

DOOR HEAD - EXISTING PARTITIOND3

0 2" 4" 8"SCALE: 3" = 1'-0"

DOOR JAMB - EXISTING PARTITIONC3

1 3'-0" WIDE PAIR OF DOORS.

2 PAINT DOOR AND FRAME.

DOOR SCHEDULE REMARKS

0 2" 4" 8"SCALE: 3" = 1'-0"

DOOR SILL - RAISED ACCESS FLOORA3

SY

M

DE

S C

RI

PT

I O N

DA

TE

4'-0" R.O.

3'- 5"

3'- 0"

R .O

BASIS OF DESIGN:

ARMORTEX BULLET

RESISTANT

ALUMINUM

TRANSACTION

WINDOW W/

SPEAKER

STAINLESS STEEL

DEAL TRAY

EXISTING COUNTER

TO REMAIN

B5

AE602

A5

AE602

4'- 6"

PATCH AND REPAIR

EXIST PARTITION AT

JAMB

BULLET RESISTANT

GLAZING

STAINLESS STEEL

CAP

STAINLESS STEEL

DEAL TRAY

MODIFY EXISTING

COUNTER TO SUIT

DEAL TRAY

8 1/8"

BULLET RESISTANT

GLAZING

PATCH AND REPAIR

EXISTING PARTITION

TO REMAIN

SEALANT AND

BACKER ROD

WOOD BLOCKING

SEALANT AND

BACKER ROD

BULLET RESISTANT

EXTRUDED

ALUMINUM FRAME

7'- 4 1

/2"

2'- 9 1

/2"

1'- 1 1

/2"

EQ

EQ

3'-4 1/2" ±

EXIST MAPES

PANEL TO REMAIN

EXIST KAWNEER

TRIFAB 451 FRAME

TO REMAIN

PROVIDE

EXTERIOR

WINDOW FILM;

BASIS OF DESIGN:

SOLYX ULTRA

COOL-S20-OSW

7'- 4 1

/2"

2'- 9 1

/2"

1'- 1 1

/2"

EQ

EQ

9'-8" ±

EQ EQ EQ

EXIST MAPES

PANEL TO REMAIN

EXIST KAWNEER

TRIFAB 451 FRAME

TO REMAIN

PROVIDE

EXTERIOR

WINDOW FILM;

BASIS OF DESIGN:

SOLYX ULTRA

COOL-S20-OSW

7'- 4 1

/2"

2'- 9 1

/2"

1'- 1 1

/2"

EQ

EQ

12'-10" ±

EQ EQ EQ EQ

EXIST MAPES

PANEL TO REMAIN

EXIST KAWNEER

TRIFAB 451

FRAME TO

REMAIN

PROVIDE

EXTERIOR

WINDOW FILM;

BASIS OF DESIGN:

SOLYX ULTRA

COOL-S20-OSW

7'- 2"

2'-

11'-11 1/2" ±

EQ EQ EQ

1'- 8 1

/2"

EQ

EQ

EXIST MAPES

PANEL TO REMAIN

EXIST KAWNEER

TRIFAB 451 FRAME

TO REMAIN

PROVIDE

EXTERIOR

WINDOW FILM;

BASIS OF DESIGN:

SOLYX ULTRA

COOL-S20-OSW

7'- 2"

2'-

EQ

EQ

1'- 8 1

/2"

7'-11 1/2" ±

EXIST MAPES

PANEL TO REMAIN

EXIST KAWNEER

TRIFAB 451 FRAME

TO REMAIN

PROVIDE

EXTERIOR

WINDOW FILM;

BASIS OF DESIGN:

SOLYX ULTRA

COOL-S20-OSW

EQ EQ

7'- 4 1

/2"

2'- 9 1

/2"

1'- 1 1

/2"

EQ

EQ

3'-4 1/2" ±

BULLET RESISTANT

WINDOW SYSTEM;

BASIS OF DESIGN:

BULLETBLOCK

TTH600 THERMALLY

BROKEN

BULLET

RESISTANT

GLAZING;

BASIS OF DESIGN:

BULLETBLOCK

BR-233 ALL

GLASS LAMINATE

PROVIDE

EXTERIOR

WINDOW FILM TO

GLAZING; BASIS

OF DESIGN:

SOLYX ULTRA

COOL-S20-OSW

A4

AE602

A3

AE602

A2

AE602

EXIST EXTERIOR

PANEL

ALUM CHANNEL TRIM;

PAINT SILVER TO

MATCH EXIST

ANODIZED ALUM

TRIM FLASHING

WITH DRIP EDGE

PROVIDE

FLASHING SET IN

CONT BED OF

SEALANT

SEALANT AND

BACKER ROD

PATCH AND REPAIR

EXIST INTERIOR

SHEATHING

EXIST WALL

ASSEMBLY

BULLET

RESISTANT

WINDOW SYSTEM

BULLET

RESISTANT

GLAZING

3-5/8" METAL STUD

5/8" GYPSUM BOARD

RE-INSTALL EXIST

SUSPENDED CEILING

SEALANT

BULLET RESISTANT

WINDOW SYSTEM

BULLET RESISTANT

GLAZING

BULLET RESISTANT

GLAZING

BULLET RESISTANT

WINDOW SYSTEM

6" SEALANT

SOLID SURFACE

WINDOW STOOL

SEALANT AND

BACKER ROD

ANODIZED

ALUMINUM SILL

FLASHING

CONT BED

OF

SEALANT

ALUM CHANNEL

TRIM; PAINT

SILVER TO

MATCH EXIST

EXIST WALL

ASSEMBLY

PATCH AND

REPAIR EXIST

INTERIOR

SHEATHING

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 8/

:0

3:

P M

C :\R ev it2

1L oc al

M od el s\

X1

-1

-A -R

_h az el

.e cl ar in al .rv t

AE602

X1

W

IN

DO

W

E

LE

VA

TI

O

NS

D

ET

AI

LS

ALP

12,911,551

HME HME

06/28/2024

JECC - MICHAEL FREDERICK

CO

RR

EC

T

NE

TW

O

RK

IN

FR

AS

TR

UC

TU

RE

D

EF

IC

IE

NC

IE

S

HAZEL ECLARINAL, R.A.

1736577

N/A

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

JOHN MILLER, P.E.

AMANDA PILLO, R.A.

M

ID

LA

N

T -P

W D

N O

R

FO

LK

AE

0 1' 2' 4'SCALE: 1/2" = 1'-0" (AE101)

TRANSACTION WINDOW C5C5

0 2" 4" 8"SCALE: 3" = 1'-0" (AE602)

SILL DETAILA5

0 2" 4" 8"SCALE: 3" = 1'-0" (AE602)

HEAD / JAMB DETAILB5

0 1' 2' 4'SCALE: 1/2" = 1'-0"

EXIST WINDOW TYPE CC40 1' 2' 4'SCALE: 1/2" = 1'-0"

EXIST WINDOW TYPE BC20 1' 2' 4'SCALE: 1/2" = 1'-0"

EXIST WINDOW TYPE AC1

0 1' 2' 4'SCALE: 1/2" = 1'-0"

EXIST WINDOW TYPE FB1 0 1' 2' 4'SCALE: 1/2" = 1'-0"

EXIST WINDOW TYPE GB2 0 1' 2' 4'SCALE: 1/2" = 1'-0"

WINDOW TYPE C1B4

0 2" 4" 8"SCALE: 3" = 1'-0" (AE602)

HEAD DETAILA40 2" 4" 8"SCALE: 3" = 1'-0" (AE602)

MULLION DETAILA30 2" 4" 8"SCALE: 3" = 1'-0" (AE602)

SILL DETAILA2

SY

M

DE

S C

RI

PT

I O N

DA

TE

GENERAL

DEMOLITION AND NEW WORK NOTE - REFER TO "DEMOLITION

NOTES" AND "NEW WORK NOTES" FOR EACH SHEET

#. GENERAL NOTE - REFER TO "GENERAL NOTES" FOR EACH SHEET

SECURITY

CARD READERCR

BALANCE MAGNETIC SWITCHBMS

DOOR PROP ALARMA

DOOR STRIKEDS

SYSTEMS PUSH BUTTON

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 8/

:4

7:

P M

C :\R ev it2

1L oc al

M od el s\

X1

-1

-E -2

1_ ha ze l.e cl ar in al

.rv t

E-001

X1

EL

EC

TR

IC

AL

S

YM

BO

LS

, L

EG

EN

D, A

BB

RE

VI

AT

IO

NS

, A

ND

N O

TE

S

DNB

12,911,552

JMG JMG

06/28/2024

JECC - MICHAEL FREDERICK

CO

RR

EC

T

NE

TW

O

RK

IN

FR

AS

TR

UC

TU

RE

D

EF

IC

IE

NC

IE

S

HAZEL ECLARINAL, R.A.

1736577

N/A

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

JOHN MILLER, P.E.

C. JEFF MORTON, P.E.

N/A

M

ID

LA

N

T -P

W D

N O

R

FO

LK

E-

GENERAL NOTES

GENERAL DEMOLITION NOTES

ELECTRICAL LEGEND

CONSTRUCTION NOTES

1/C ONE CONDUCTOR

A AMPERAGE OR AMPS

AFF ABOVE FINISHED FLOOR

ARF ABOVE RAISED FLOOR

BKR BREAKER

C CONDUIT

CB CIRCUIT BREAKER

CKT CIRCUIT

DWG DRAWING

EA EACH

EC EMPTY CONDUIT

ELEC ELECTRICAL

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EQUIP EQUIPMENT

EXIST EXISTING

FT FEET

GFCI GOVERNMENT FURNISHED CONTRACTOR INSTALLED

GFE GOVERNMENT FURNISHED EQUIPMENT

GFGI GOVERNMENT FURNISHED GOVERNMENT INSTALLED

GFI GROUND FAULT INTERRUPTER

GND GROUND

HGT HEIGHT

HUB COMPUTER DISTRIBUTION HUB

LED LIGHT EMITTING DIODE

LTS LUMINAIRE

MTD MOUNTED

MTG HT MOUNTING HEIGHT

NEC NATIONAL ELECTRICAL CODE

NF NON FUSIBLE

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OS OCCUPANCY SENSOR

PNL PANEL

PNLBD PANELBOARD

QU QUANTITY

REC RECEPTACLE

REQ'D REQUIRED

RM ROOM

SHT SHEET

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

V VOLTAGE OR VOLTS

W WIRE

Ø PHASE

ABBREVIATIONS

1 EQUIPMENT SHOWN WITH DASHED LINE MUST BE REMOVED, UON.

2 WIRING TO EQUIPMENT MUST BE REMOVED, UON.

3 CONDUIT MUST BE REMOVED, UON.

4 CONDUIT CONCEALED IN WALLS AND SLABS MUST BE BLANKED OFF AND

ABANDONED IN PLACE. PATCH WALLS AND SLABS AFTER DEMOLITION IS

COMPLETE.

5 BOXES DISCONTINUED MUST BE BLANKED OFF OR REMOVED AND DEVICES

REMOVED.

6 EXISTING ELECTRICAL EQUIPMENT NOT INDICATED ON DEMOLITION PLAN

MUST REMAIN CONNECTED FOR CONTINUED USE.

7 CONTRACTOR MUST RECONNECT EXISTING CIRCUIT(S) (INTERRUPTED BY

REMOVAL OF EXISTING DEVICE) TO THE REMAINING ELECTRICAL

EQUIPMENT LOCATED DOWNSTREAM FROM THE POINT OF INTERRUPTION.

1 ALL ELECTRICAL WORK AND MATERIAL IS NEW AND MUST BE PROVIDED BY

THE CONTRACTOR UON.

2 AN EQUIPMENT GROUND WIRE MUST BE RUN WITH FEEDERS AND BRANCH

CIRCUITS.

3 WIRING MUST BE AS PER NATIONAL ELECTRICAL CODE (NEC).

4 ELECTRICAL EQUIPMENT MUST BE IDENTIFIED AND LABELED.

5 FEEDERS/CIRCUITS MUST BE IDENTIFIED AT EACH END OF THE WIRE AND

AT EVERY SPLICE OR JUNCTION/PULL BOX.

6 PROVIDE NEW TYPED DIRECTORIES FOR PANELS (NEW OR EXISTING)

INCLUDED IN THIS PROJECT.

7 INTERIOR WIRING SYSTEMS MUST BE CONCEALED WITH FLUSH MOUNTED

BOXES/DEVICES, UON.

8 DRAWINGS ARE BASED ON EXISTING BUILDING PLANS AND FIELD

INVESTIGATIONS. CONTRACTOR MUST VISIT THE EXISTING BUILDING AND

ACQUAINT HIMSELF/HERSELF WITH THE EXISTING CONDITIONS.

CONTRACTOR MUST EXAMINE DRAWINGS TO AVOID CONFLICT.

9 COORDINATE LOCATION AND POWER REQUIREMENTS OF ELECTRICAL

DEVICES WITH MECHANICAL, PLUMBING, ARCHITECTURAL AND FIRE

PROTECTION DRAWINGS.

10 ELECTRICAL DEVICES SHOWN BUT NOT CIRCUITED MUST REMAIN ON

THEIR EXISTING CIRCUIT.

11 SINGLE PHASE (120/208V) BRANCH CIRCUITS MUST CONSIST OF 2#12 & 1#12

GND. IN 1/2"C UON. THREE PHASE BRANCH CIRCUITS CONSIST OF 3#12 &

1#12 GND IN 1/2"C UON.

12 REFER TO PLANS FOR CONDUCTOR SIZING. COMPLY WITH THE FOLLOWING

GUIDELINES FOR CONDUCTOR RUN LENGTHS:

20A,120V CIRCUITS LONGER THAN 100' - USE #10 AWG TO LIMIT VOLTAGE

DROP ON BRANCH CIRCUITS TO 3%

20A, 120V CIRCUITS LONGER THAN 150' - USE #8 AWG TO LIMIT VOLTAGE

DROP ON BRANCH CIRCUITS TO 3%

13 COORDINATE ELECTRICAL WORK WITH ARCHITECTURAL, MECHANICAL AND

FIRE PROTECTION WORK PRIOR TO FABRICATION AND INSTALLATION TO

PREVENT CONFLICTS. NOTIFY CONTRACTING OFFICER WHERE CONFLICTS

ARE DISCOVERED PRIOR TO CONSTRUCTION AND BEFORE BEGINNING

WORK IN THOSE AREAS. ALL CONFLICTS THAT ARISE DUE TO LACK OF

COORDINATION MUST BE RECTIFIED BY THE CONTRACTOR AT NO COST TO

THE GOVERNMENT.

1 CONTRACTOR MUST PROVIDE A MINIMUM OF 2 WEEKS NOTICE OF POWER

OUTAGES TO ACTIVITY AND GOVERNMENT OFFICIAL.

SY

M

DE

S C

RI

PT

I O N

DA

TE

DN

DN

DN

DN

DN

ED101

C1

ED101

C2

ED101

D3

ED101

C3

ED101

D2

VESTIBULE

SECURITY

1 VESTIBULE

OPEN

OFFICE

HALL

HALL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 8/

:4

7:

P M

C :\R ev it2

1L oc al

M od el s\

X1

-1

-E -2

1_ ha ze l.e cl ar in al

.rv t

ED101

X1

FL

O

O R

PL

AN

DE

M O

LI

TI

O N

DNB

12,911,553

JMG JMG

06/28/2024

JECC - MICHAEL FREDERICK

CO

RR

EC

T

NE

TW

O

RK

IN

FR

AS

TR

UC

TU

RE

D

EF

IC

IE

NC

IE

S

HAZEL ECLARINAL, R.A.

1736577

N/A

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

JOHN MILLER, P.E.

C. JEFF MORTON, P.E.

N/A

M

ID

LA

N

T -P

W D

N O

R

FO

LK

ED

1/4" = 1' - 0" 0 5' 10' 15'1'

1/16" = 1' - 0" 0 5' 10' 20' 30' 60'

GRAPHIC SCALE(S)

KEY PLAN

KEYNOTES

GENERAL SHEET NOTES

PLAN

NORTH

SCALE: 1/16" = 1'-0"

FIRST FLOOR PLAN - DEMOLITIONA1

SCALE: 1/4" = 1'-0"C1 SECURITY 106/VESTIBLE 105 - DEMOLITION

SCALE: 1/4" = 1'-0"C2 VESTIBULE 122 - DEMOLITION

SCALE: 1/4" = 1'-0"D3 OPEN OFFICE 138 - DEMOLITION

SCALE: 1/4" = 1'-0"C3 HALL 180 - DEMOLITION

SCALE: 1/4" = 1'-0"D2 HALL180/WAREHOUSE - DEMOLITION

A REFER TO SHEET E-001 FOR GENERAL DEMOLITION NOTES.

B PROVIDE ALL ELECTRICAL DEMOLITION WORK NECESSARY TO INSTALL

NEW WORK. REROUTE AND RECONNECT CIRCUITS (POWER AND

TELECOMMUNICATIONS) THAT WILL REMAIN IN USE, BUT INTERFERES WITH

NEW CONSTRUCTION. REMOVE ALL WIRING FROM ABANDONED CONDUITS

AND DISCONNECT FROM ALL POWER SOURCES.

C ALL EXISTING CONDUITS THAT WILL NOT BE REUSED SHALL BE REMOVED.

ONLY CONDUITS IN WALLS THAT ARE TO REMAIN AND THAT DO NOT

INTERFERE WITH NEW WORK MAY BE ABANDONED IN PLACE.

D CIRCUITS SHOWN ARE BASED ON FIELD AND DRAWING INVESTIGATIONS.

CONTRACTOR SHALL VEIRFY ALL CIRCUITS PRIOR TO DEMOLITION.

E REFER TO ARCHITECTURAL SHEETS FOR EACH ROOM UNIT TYPE.

1 DISCONNECT, REMOVE, AND SALVAGE THE EXISTING ELECTRONIC

SECURITY DEVICES AT DOORS.

SY

M

DE

S C

RI

PT

I O N

DA

TE

AP

DCA B E

DN

DN

DN

DN

DN

EP101

C1

EP101

C2

EP101

D3

EP101

C3

EP101

D2

VESTIBULE

SECURITY

1 VESTIBULE

OPEN

OFFICE

HALL

HALL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 8/

:4

7:

P M

C :\R ev it2

1L oc al

M od el s\

X1

-1

-E -2

1_ ha ze l.e cl ar in al

.rv t

EP101

X1

FL

O

O R

PL

AN

PO

W

ER

DNB

12,911,554

JMG JMG

06/28/2024

JECC - MICHAEL FREDERICK

CO

RR

EC

T

NE

TW

O

RK

IN

FR

AS

TR

UC

TU

RE

D

EF

IC

IE

NC

IE

S

HAZEL ECLARINAL, R.A.

1736577

N/A

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

JOHN MILLER, P.E.

C. JEFF MORTON, P.E.

N/A

M

ID

LA

N

T -P

W D

N O

R

FO

LK

EP

1 REINSTALL AND RECONNECT ELECTRONIC SECURITY SYSTEM DEVICES AT

DOOR. RECONNECT TO CIRCUIT RETAINED IN DEMOLITION.

1/4" = 1' - 0" 0 5' 10' 15'1'

1/16" = 1' - 0" 0 5' 10' 20' 30' 60'

GRAPHIC SCALE(S)

KEY PLAN

KEYNOTES

GENERAL SHEET NOTES

PLAN

NORTH

SCALE: 1/16" = 1'-0"

FIRST FLOOR PLAN - POWERA1

SCALE: 1/4" = 1'-0"C1 SECURITY 106/VESTIBLE 105 - POWER

SCALE: 1/4" = 1'-0"C2 VESTIBULE 122 - POWER

SCALE: 1/4" = 1'-0"D3 OPEN OFFICE 138 - POWER

SCALE: 1/4" = 1'-0"C3 HALL 180 - POWER

SCALE: 1/4" = 1'-0"D2 HALL 180/WAREHOUSE - POWER

A REFER TO SHEET E-001 FOR GENERAL DEMOLITION NOTES.

B PROVIDE ALL ELECTRICAL DEMOLITION WORK NECESSARY TO INSTALL

NEW WORK. REROUTE AND RECONNECT CIRCUITS (POWER AND

TELECOMMUNICATIONS) THAT WILL REMAIN IN USE, BUT INTERFERES WITH

NEW CONSTRUCTION. REMOVE ALL WIRING FROM ABANDONED CONDUITS

AND DISCONNECT FROM ALL POWER SOURCES.

C ALL EXISTING CONDUITS THAT WILL NOT BE REUSED SHALL BE REMOVED.

ONLY CONDUITS IN WALLS THAT ARE TO REMAIN AND THAT DO NOT

INTERFERE WITH NEW WORK MAY BE ABANDONED IN PLACE.

D CIRCUITS SHOWN ARE BASED ON FIELD AND DRAWING INVESTIGATIONS.

CONTRACTOR SHALL VEIRFY ALL CIRCUITS PRIOR TO DEMOLITION.

E REFER TO ARCHITECTURAL SHEETS FOR EACH ROOM UNIT TYPE.

SY

M

DE

S C

RI

PT

I O N

DA

TE

AP

DCA B E

EXIT DEVICE

DOOR

EXISTING JUNCTION BOX

EXISITING CONDUIT TO

SECURITY

WIREWAY/PULLBOX

NOTE:

1. COORDINATE CONDUIT ROUGH-IN AND PROVIDE WIRING IN ACCORDANCE WITH DOOR CONTROLLER SUPPLIER'S RECOMMENDATION.

2. MORTISE LOCK, ELECTRIC POWER TRANSFER AND ALL OTHER DOOR HARDWARE MUST MATCH EXISTING HARDWARE USED THROUGHOUT BUILDING.

3. BOX/CONDUIT LOCATIONS ARE CONCEPTUAL ONLY. FIELD VERIFY FINAL LOCATIONS WITH SECURITY.

4. RUN ALL CABLING IN DOOR FRAME WHERE POSSIBLE. PROVIDE ALL NECESSARY CONDUIT, CABLING, AND SUPPORTS FOR ELECTRONIC POWER TRANSFERS AS NECESSARY. PROVIDE HIGH SECURITY POWER TRANSFER LOOPS AS NECESSARY BETWEEN DOOR AND FRAME TO PROVIDE COMPLETE

AND FUNCTIONAL SYSTEM.

FLOOR

FINISHED

CEILING

EXISTING CONDUIT

BOX FOR BMS

CONNECTION

SECURED SIDE

7 PIN RIM

CYLINDER

ELECTRIC

PANIC BAR

MORTISE LOCK

DOOR

EXISTING JUNCTION BOX

(SECURED SIDE)

EXISTING CONDUIT TO

SECURITY

WIREWAY/PULLBOX

FLOOR

FINISHED

CEILING

3/4" C

X10 LOCK

UNSECURED SIDE

DOUBLE JUNCTION

BOX FOR CARD

READER AND KEYPAD

ELECTRIC POWER

TRANSFER

DOOR AJAR

SENSOR

EXIT DEVICE

DOOR AJAR

SENSOR

EXIST JUNCTION BOX

EXIST CONDUIT TO

SECURITY

WIREWAY/PULLBOX

NOTE:

1. COORDINATE CONDUIT ROUGH-IN AND PROVIDE WIRING IN ACCORDANCE WITH DOOR CONTROLLER SUPPLIER'S RECOMMENDATION.

2. MORTISE LOCK, ELECTRIC POWER TRANSFER AND ALL OTHER DOOR HARDWARE MUST MATCH EXISTING HARDWARE USED THROUGHOUT BUILDING.

3. BOX/CONDUIT LOCATIONS ARE CONCEPTUAL ONLY. FIELD VERIFY FINAL LOCATIONS WITH SECURITY.

4. RUN ALL CABLING IN DOOR FRAME WHERE POSSIBLE. PROVIDE ALL NECESSARY CONDUIT, CABLING, AND SUPPORTS FOR ELECTRONIC POWER TRANSFERS AS NECESSARY. PROVIDE HIGH SECURITY POWER TRANSFER LOOPS AS NECESSARY BETWEEN DOOR AND FRAME TO PROVIDE COMPLETE

AND FUNCTIONAL SYSTEM.

FLOOR

FINISHED

CEILING

EXIST CONDUIT

BOX FOR BMS

CONNECTION

SECURED SIDE

DOOR

EXIST JUNCTION BOX

(SECURED SIDE)

1" C TO SECURITY

WIREWAY/PULLBOX

FLOOR

FINISHED

CEILING

EXIST CONDUIT

UNSECURED SIDE

ELECTRIC POWER

TRANSFER

DOOR

REMOVABLE

MULLION

DOUBLE JUNCTION BOX

FOR CARD READER AND

KEYPAD

X10

LOCK

7 PIN RIM CYLINDER EXIT

DEVICE MORTISE LOCK

DOOR CLOSER

MORTISE

DOOR BOLT

DOOR

CLOSER

DOOR

EXISTING JUNCTION BOX

EXIST CONDUIT TO

SECURITY

WIREWAY/PULLBOX

NOTE:

1. COORDINATE CONDUIT ROUGH-IN AND PROVIDE WIRING IN ACCORDANCE WITH DOOR CONTROLLER SUPPLIER'S RECOMMENDATION.

2. MORTISE LOCK, ELECTRIC POWER TRANSFER AND ALL OTHER DOOR HARDWARE MUST MATCH EXISTING HARDWARE USED THROUGHOUT BUILDING.

3. BOX/CONDUIT LOCATIONS ARE CONCEPTUAL ONLY. FIELD VERIFY FINAL LOCATIONS WITH SECURITY.

4. RUN ALL CABLING IN DOOR FRAME WHERE POSSIBLE. PROVIDE ALL NECESSARY CONDUIT, CABLING, AND SUPPORTS FOR ELECTRONIC POWER TRANSFERS AS NECESSARY. PROVIDE HIGH SECURITY POWER TRANSFER LOOPS AS NECESSARY BETWEEN DOOR AND FRAME TO PROVIDE COMPLETE

AND FUNCTIONAL SYSTEM.

FLOOR

FINISHED

CEILING

EXISTING CONDUIT

BOX FOR BMS

CONNECTION

SECURED SIDE

7 PIN RIM

CYLINDER

ELECTRIC EXIT

DEVICE

MORTISE LOCK

DOOR

EXISTING JUNCTION BOX

(SECURED SIDE)

1" C TO SECURITY

WIREWAY/PULLBOX

FLOOR

FINISHED

CEILING

EXISITNG CONDUIT

X10 LOCK

UNSECURED SIDE

DOUBLE JUNCTION

BOX FOR CARD

READER AND KEYPAD

ELECTRIC POWER

TRANSFER

EXIT DEVICE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

7/ 8/

:5

0:

P M

C :\R ev it2

1L oc al

M od el s\

X1

-1

-E -2

1_ ha ze l.e cl ar in al

.rv t

EP501

X1

EL

EC

TR

IC

AL

D

ET

AI

LS

DNB

12,911,555

JMG JMG

06/28/2024

JECC - MICHAEL FREDERICK

CO

RR

EC

T

NE

TW

O

RK

IN

FR

AS

TR

UC

TU

RE

D

EF

IC

IE

NC

IE

S

HAZEL ECLARINAL, R.A.

1736577

N/A

NO

RF

OL

K, V

IR

GI

NI

A

NA

VA

L S

TA

TI

ON

JOHN MILLER, P.E.

C. JEFF MORTON, P.E.

N/A

M

ID

LA

N

T -P

W D

N O

R

FO

LK

EP

SCALE: NOT TO SCALEA3 ELECTRONIC SINGLE DOOR LOCK DETAIL

SY

M

DE

S C

RI

PT

I O N

DA

TE

AP

PR

SCALE: NOT TO SCALEA1 ELECTRONIC PAIR DOOR LOCK DETAIL

SCALE: NOT TO SCALEC1 ELECTRONIC PAIR (UNEVEN) DOOR LOCK DETAIL

Sheets
GI001 - COVER SHEET
GI002 - LIST OF SHEETS, GENERAL PROJECT NOTES AND SYMBOLS
A-001 - ARCHITECTURAL ABBREVIATIONS, NOTES, SYMBOLS, AND OVERALL PLAN
AD101 - FIRST FLOOR PLAN - PART D/E - DEMOLITION
AD102 - FIRST FLOOR PLAN - AREA C - DEMOLITION
AE101 - FIRST FLOOR PLAN - PART D/E - NEW WORK
AE102 - FIRST FLOOR PLAN - PART C - NEW WORK
AE601 - DOOR SCHEDULE AND DETAILS
AE602 - WINDOW ELEVATIONS & DETAILS
E-001
ED101
EP101
EP501

2024-07-08T16:44:07-0400

2024-07-08T16:44:21-0400

2024-07-08T16:44:21-0400

2024-07-08T16:44:21-0400

2024-07-08T16:44:22-0400

2024-07-08T16:44:22-0400

2024-07-08T16:44:23-0400

2024-07-08T16:44:23-0400

2024-07-08T16:44:23-0400

2024-07-08T16:44:23-0400

2024-07-08T16:44:24-0400

2024-07-08T16:44:24-0400

2024-07-08T16:44:24-0400

2024-07-08T16:45:22-0400

2024-07-08T16:45:38-0400

2024-07-08T16:45:38-0400

2024-07-08T16:45:38-0400

2024-07-08T16:45:38-0400

2024-07-08T16:45:39-0400

2024-07-08T16:45:39-0400

2024-07-08T16:45:39-0400

2024-07-08T16:45:39-0400

2024-07-08T16:45:40-0400

2024-07-08T16:45:40-0400

2024-07-08T16:45:40-0400

2024-07-08T16:45:41-0400

2024-07-08T16:46:48-0400

2024-07-08T16:47:09-0400

2024-07-08T16:47:09-0400

2024-07-08T16:47:09-0400

2024-07-08T16:47:09-0400

2024-07-08T16:47:10-0400

2024-07-08T16:47:10-0400

2024-07-08T16:47:10-0400

2024-07-08T16:47:11-0400

File details come from the government source that posted it. Updated .