This document appears to be a technical specification for bullet-resistant components, including steel windows, speaking apertures, gun ports, and pass-through drawers. It outlines the design requirements, performance criteria, submittal procedures, and installation instructions for these bullet-resistant products. Key details include:
The specification covers bullet-resistant steel windows with laminated glass, adhesive interlayer materials, and sealants that must meet specified threat levels. It also includes requirements for bullet-resistant speaking apertures, gun ports, and pass-through drawers that are fabricated from bullet-resistant steel. The components must be labeled with manufacturing details and threat level information. Shop finishing, electrical wiring, and installation procedures are also specified. The document references multiple ASTM, AAMA, and other industry standards that the products must conform to. Overall, this specification provides detailed technical requirements for the procurement and installation of bullet-resistant components for a federal facility.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X-132 Correct Network Infrastructure 1736577
SECTION 08 34 02
BULLET-RESISTANT COMPONENTS
08/09
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF45 (2003; Reaffirmed 2009) Designation System for Aluminum Finishes
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
AAMA 611 (2014) Voluntary Specification for Anodized Architectural Aluminum
ASTM INTERNATIONAL (ASTM)
ASTM A123/A123M (2017) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products
ASTM A653/A653M (2023) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM C1036 (2021) Standard Specification for Flat Glass
ASTM C1048 (2018) Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass
ASTM C1172 (2019) Standard Specification for Laminated Architectural Flat Glass
ASTM D905 (2008; E 2009) Strength Properties of Adhesive Bonds in Shear by Compression Loading
ASTM D1003 (2013) Haze and Luminous Transmittance of Transparent Plastics
ASTM D1044 (2019) Standard Test Method for Resistance of Transparent Plastics to Surface Abrasion by the Taber Abraser
ASTM D3951 (2018) Commercial Packaging
ASTM D4093 (1995; R 2014) Photoelastic Measurements
SECTION 08 34 02 Page 1 of Birefringence and Residual Strains in Transparent or Translucent Plastic Materials
ASTM E1300 (2016) Standard Practice for Determining Load Resistance of Glass in Buildings
ASTM F428 (2019) Intensity of Scratches on Aerospace Glass Enclosures
ASTM F520 (2021) Standard Test Method for Environmental Resistance of Aerospace Transparencies to Artificially Induced Exposures
ASTM F521 (2022) Standard Test Methods for Bond Integrity of Transparent Laminates
ASTM F548 (2019) Standard Test Method for Intensity of Scratches on Aerospace Transparent Plastics
ASTM F735 (2022) Standard Test Method for Abrasion Resistance of Transparent Plastics and Coatings Using the Oscillating Sand Method
ASTM F1233 (2021) Standard Test Method for Security Glazing Materials and Systems
GLASS ASSOCIATION OF NORTH AMERICA (GANA)
GANA Glazing Manual (2008) Glazing Manual
NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS (NAAMM)
NAAMM HMMA 840 (2017) Guide Specifications for Receipt, Storage and Installation of Hollow Metal Doors and Frames
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 70 (2023; ERTA 7 2023; TIA 23-15) National Electrical Code
NATIONAL INSTITUTE OF JUSTICE (NIJ)
NIJ Std 0108.01 (1985) Ballistic Resistant Protective Materials
UNDERWRITERS LABORATORIES (UL)
UL 752 (2023) UL Standard for Safety Bullet-Resisting Equipment
1.2 SYSTEM DESCRIPTION
1.2.1 Design Requirements
Provide bullet resistant components conforming to the requirements
SECTION 08 34 02 Page 2 specified for the particular items and, as much as possible, complete assemblies by a single manufacturer.
1.2.2 Performance Requirements
Specify all bullet resistant items to the threat specified. Operate movable and operable components smoothly and freely. When a reference for performance is listed, conform to referenced requirements.
1.2.3 Submittal Requirement Details
Submit the followin:
a. Manufacturer's descriptive data and installation instructions.
Include cleaning instructions as recommended by the plastic sheet manufacturer.
d. Lists including schedule of all components to be incorporated in the work with manufacturer's model or catalog numbers, specification and drawing reference numbers, warranty information, threat level certified, insulation "U" value, and number of items provided.
e. Evidence that standard products essentially duplicate items that have been satisfactorily in use for two years or more, including name of purchasers, locations of installations, dates of installations, and service organizations.
f. Manufacturer's certificates attesting that all components conform to the requirements on drawings and in specifications. Include testing reports from independent testing laboratories indicating conformance to regulatory requirements.
1.3 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Installation; G
SD-07 Certificates
Bullet Resistant Components
1.4 QUALITY ASSURANCE
Provide Bullet-resistant components at locations shown on the drawings.
Bullet-resistant components where indicated must be in accordance with NIJ Type IIIA of NIJ Std 0108.01 or UL SPSA of UL 752 or ASTM Handgun (.44 Magnum) of ASTM F1233.
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver components to the job site with the brand, name, and model number clearly marked thereon. Deliver, store and handle all components so as not to be damaged or deformed, and in accordance with ASTM D3951. Handle
SECTION 08 34 02 Page 3 windows carefully to prevent damage to the faces, edges, corners, ends, and glazing. Clean, repair, or replace abraded, scarred, or rusty areas immediately upon detection. Replace damaged components that cannot be restored to like-new condition. Store components and equipment in a dry location on platforms or pallets that are ventilated adequately, free of dust, water, and other contaminants, and stored in a manner which permits easy access for inspection and handling.
1.6 SCHEDULING
Glaze bullet-resistant windows, except factory-glazed units, after all concrete, masonry, ceiling, electrical, mechanical, plumbing, and adjacent finish work is complete to avoid damage to the glazing material. Cover factory-glazed windows to protect them from damage during adjacent finish work.
1.7 WARRANTY
Furnish manufacturer's warranty for 5 years for glazing materials.
Provide for replacement and installation of glazing if delamination, discoloration, or cracking, or crazing occurs.
PART 2 PRODUCTS
2.1 MATERIALS AND COMPONENTS
Provide materials and components which are the standard products of a manufacturer regularly engaged in the manufacture of such products, unless otherwise indicated and detailed on the drawings, and that essentially duplicate items that have been in satisfactory use for at least two years prior to bid opening. Provide components supported by a service organization that is, in the opinion of the Contracting Officer, reasonably convenient to the site, or by the manufacturer. Where components are detailed on the drawings and do not conform to a manufacturer's standard product, provide components that are constructed of manufacturer's standard materials which conform to the specified ballistic standard or test. Provide bullet-resistant component assemblies of size and type indicated and provide at locations shown. Design all items included for exterior installation to resist water penetration or entrapment.
2.2 ELECTRICAL WIRING
Provide electrical wiring and conduit as specified in Section 26 20 00
INTERIOR DISTRIBUTION SYSTEM.
2.3 BULLET-RESISTANT STEEL WINDOWS
Fabricate window assemblies from bullet-resistant steel shapes or hollow metal with internal armoring and bullet-resistant glazing materials specified herein; the entire assembly must meet or exceed the specified regulatory requirements. Provide welded frame units of sizes and shapes indicated on the drawings with minimum frame face dimensions of 2 inches.
Furnish glazing material with window assembly for onsite installation, or furnish factory glazed window units. Entire assembly must be furnished by same manufacturer. Weld exterior (attack side) glazing stops or integral to frame. Provide removable interior (protected side) glazing stops attached with high-strength alloy steel machine screws with tamper-resistant heads.
SECTION 08 34 02 Page 4
2.3.1 Glazing Materials
Provide factory fabricated units designed to be bullet-resistant to the specified test standard in paragraph COMPONENT TEST REQUIREMENTS. Glazing material must be glass with a low-spall protected (interior) face.
Low-spall interior face must meet or exceed requirements for spall resistance defined in UL 752 . Provide glazing material conforming to applicable requirements contained in ASTM C1036, ASTM C1048, and ASTM E1300.
Test glazing materials in accordance with the applicable sections of the following testing procedures: ASTM D905, ASTM D1003, ASTM F428, ASTM F548, ASTM D4093, and ASTM F520.
2.3.1.1 Laminated Glass
Provide bullet-resistant laminated glass consisting of all glass laminated construction conforming to applicable sections of ASTM C1172. The adhesive interlayer material for bonding glass to glass must be chemically compatible with the surfaces which are to be bonded. Test materials selected for lamination purposes in accordance with the following testing procedures: ASTM D905, ASTM D1044, ASTM F735, ASTM D4093, ASTM F521, ASTM F520, and ASTM D1003. Use glass plies in the lamination that are annealed float glass conforming to Type I, quality q3 Class 1, in accordance with ASTM C1036 or heat-strengthened or fully heat tempered, float glass, Condition A, Type I, q3 Class 1, in accordance with ASTM C1048.
2.3.2 Adhesive Interlayer Materials
Provide adhesive interlayer materials for bonding laminates (glass-glass, glass-plastic, or plastic-plastic bonds) that are chemically compatible with the surfaces being bonded. Interlayer materials may be polyvinyl butyral, cast-in-place urethane, proprietary materials, sheet form urethane and other materials. Do not use polyvinyl butyral to bond polycarbonate. Provide adhesives in accordance with ASTM D905 and manufacturer's recommendations.
2.3.3 Sealants
Furnish sealants for glazings that are chemically compatible with the glazing materials they contact with no deleterious effects to the glazing materials or to the adhesives used in laminates. Sealants must be in accordance with glazing manufacturer's recommendations and GANA Glazing Manual .
2.3.4 Deal Trays
Provide nominal 12-3/4 inch wide by 1-5/8 inch high opening in sill of window frame . Provide deal tray welded subassembly of window assembly conforming to specified requirements for entire window assembly. Provide opening configuration of deal tray that prevents ballistic penetration or spall from the threat weapon, and resists lead spray from a shotgun blast. Provide tray opening that prevents insertion of the muzzle of a firearm.
2.4 BULLET-RESISTANT SPEAKING APERTURES
Fabricate speaking apertures to allow passage of voice at normal speaking volume without distortion, to resist the specified threat level for indoor use, and designed to prevent direct aim by the insertion of the muzzle of
SECTION 08 34 02 Page 5 any firearm. Finish must match window construction in which aperture is installed.
2.5 BULLET-RESISTANT GUNPORTS
Operate only from the protected side of the barrier, with a protected side shutter that closes automatically and is lockable from the protected side. Fabricate gunport from bullet resistant steel shapes and the entire assembly must meet or exceed the specified regulatory requirements. Size gunport for operation using submachine guns and rifles. Provide hinged or pivoted shutterand do not obstruct operation when in open position.
Attach to wall assembly in accordance with manufacturer's recommendations. Include all aspects of gunport assembly, including hardware and method of anchorage to wall, in labeling or test certification. Provide satin stainless steel finish. Gunport must not be operable from exposed side.
2.6 BULLET-RESISTANT PASS-THROUGH DRAWER
Fabricate pass-through drawer from bullet-resistant steel shapes; the entire assembly must meet or exceed the specified regulatory requirements. Provide pass-through drawer of size indicated on the drawings and designed to prohibit forcible entry or direct aim by the insertion of the muzzle of a firearm from exterior side when drawer is in the open position. Attach to wall assembly in accordance with manufacturer's recommendations. Include all aspects of the assembly, including hardware and method of anchorage to wall, in the labeling or test certification. Provide satin stainless steel finish.
2.7 ACCESSORIES
Provide all accessories for the installation or erection of above components into the surrounding structure. Anchorage must be as strong and bullet-resistant as the components. Install/erect in accordance with manufacturer's recommended instructions.
2.8 LABELING
Plainly label bullet-resistant equipment in accordance with regulatory requirements. Provide label that is compatible with plastic or coating, visible only on protected side, after installation, including the following information:
a. Manufacturer's name or identifying symbol
b. Model Number, Control Number, or equivalent
c. Date of manufacture by week, month or quarter and year. This may be abbreviated or be in a traceable code such as the lot number.
d. Correct mounting position including threat side and secure side (by removable label on glazing material).
e. Code indicating bullet-resistant rating and test standard used (by removable label on glazing material).
2.9 SHOP/FACTORY FINISHING
Furnish all ferrous metal components, except stainless steel, primed for
SECTION 08 34 02 Page 6 painting unless indicated otherwise. Perform finish painting in accordance with Section 09 90 00 PAINTS AND COATINGS, unless otherwise indicated. When anodic coatings are specified, the coatings must conform to AAMA 611, with coating thickness not less than that specified for protective and decorative type finish in AA DAF45. Apply a polished satin finish pretreatment and a clear lacquer overcoat to anodized items. Shop finish all factory or manufactured components as indicated.
2.9.1 Ferrous Metal
Clean surfaces of ferrous metal, except galvanized and stainless steel surfaces, and shop coat with the manufacturer's standard protective coating other than a bituminous protective coating, compatible with finish coats. Prior to shop painting, clean surfaces with solvents to remove grease and oil, and with power wire-brushing or sandblasting to remove loose rust, loose mill scale and other foreign substances. Do not shop paint surfaces of items to be embedded in concrete.
2.9.2 Galvanizing
Items specified to be galvanized must be hot-dip processed after fabrication. Galvanize in accordance with ASTM A123/A123M or ASTM A653/A653M as applicable.
2.9.3 Aluminum
Unless otherwise specified, aluminum items must be standard mill finish.
For anodic coatings see paragraph SHOP/FACTORY FINISHING above.
PART 3 EXECUTION
3.1 EXAMINATION
Field verify dimensions of rough openings for components, and that surfaces of openings are plumb, true, and provide required clearances.
Protect surrounding work prior to installation of bullet-resistant components. Restore surrounding work which is damaged as a result of the installation of bullet-resistant components to like-new condition prior to acceptance of the work described herein. Examine existing work to ensure that it is ready for installation or erection of the components. Check and correct components for racking, twisting, and other malformation prior to installation. Set frames true, plumb and aligned for proper installation. Examine all surfaces and connections for damage prior to installation.
3.2 FRAMED INSTRUCTIONS
Post framed instructions, under glass or in plastic with all edges laminated, including wiring and control diagrams showing the complete layout of each bifold door unit, where directed. Prepare condensed operating instructions explaining preventive maintenance procedures, methods of checking for normal safe operation, and procedures for safely starting and stopping in typed form, frame as specified above and post beside the diagrams. Post the framed instructions before acceptance testing.
3.3 INSTALLATION
Provide finished work that is rigid, neat in appearance and free from
SECTION 08 34 02 Page 7 defects. Install equipment plumb, level, and secured rigidly in place.
Install doors and frames conforming to NAAMM HMMA 840. Install doors, frames, and hardware in strict compliance with approved printed instructions and detail drawings provided by the manufacturer. The Contractor is responsible for proper installing of the door assembly so that operating clearances and bearing surfaces conform to manufacturer's instructions. Install weatherstripping and thresholds at exterior door openings to provide a weathertight installation. Install all other components in accordance with approved manufacturer's recommended instructions. Test all operable parts of components for smooth, trouble-free operation, in the presence of the Contracting Officer.
Submit Drawings containing complete wiring and schematic diagrams, where appropriate, and any other details required to demonstrate that the system has been coordinated and will properly function as a unit. Show proposed layout and anchorage of components and appurtenances, and relationship to other parts of work including clearances for operation and maintenance.
Show conformance to all requirements, including fabrication details, sizes, thickness of materials, anchorage, finishes, hardware location and installation.
3.4 FASTENERS
Fasteners exposed to view must match in color and finish and must harmonize with the material to which fasteners are applied.
3.5 CORROSION PROTECTION - DISSIMILAR MATERIALS
Give contact surfaces between dissimilar metals and aluminum surfaces in contact with concrete, masonry, pressure-treated wood or absorptive materials subject to wetting, a protective coating in accordance with Section 09 90 00 PAINTS AND COATINGS.
3.6 ELECTRICAL WORK
Perform all electrical work in accordance with Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM. Make flexible connections between doors and fixed supports with extra flexible type SO cable, except in hazardous locations where wiring conforms to NFPA 70 . Provide cable consisting of a spring-loaded automatic take up reel, or an equivalent and approved device.
3.7 ADJUSTING/CLEANING
Make adjustments to doors and pass-thru drawers to assure smooth operation. Units must be weathertight when closed and locked. Clean all components in accordance with manufacturer's instructions.
-- End of Section --
SECTION 08 34 02 Page 8
SECTION 08 51 69.10
ALUMINUM STORM (BULLET RESISTANT) WINDOWS
08/20
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF45 (2003; Reaffirmed 2009) Designation System for Aluminum Finishes
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
AAMA 611 (2014) Voluntary Specification for Anodized Architectural Aluminum
AAMA 1002 (2011) Voluntary Specification for Secondary Storm Products for Windows and Sliding Glass Doors
ASTM INTERNATIONAL (ASTM)
ASTM C920 (2018) Standard Specification for Elastomeric Joint Sealants
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Storm (Bullet Resistant) Windows
SD-03 Product Data
Storm (Bullet Resistant) Windows
SD-10 Operation and Maintenance Data
Storm (Bullet Resistant) Windows, Data Package 1; ; G
1.2.1 Shop Drawing Information
Submit drawings showing elevations of units, full-sized section, thicknesses and gages of material, fastenings, methods of anchorage, size and spacing of anchors, and locations of operating hardware. Indicate method of glazing, method of attaching and operating both screen and glass insert panels, and method and materials for weatherstripping. Include
SECTION 08 51 69.10 Page 1 mullion details, details of installation, and connections with other work, including details of existing windows and adjacent construction.
1.2.2 Product Data Submittal Requirements
Submit complete descriptive literature for each type of storm (bullet resistant) window and accessory. Clearly mark data to indicate which type, size, model, or item is to be provided. Data must include instructions for adjustments, cleaning, and maintenance.
1.3 DELIVERY, STORAGE, AND HANDLING
Deliver products to the project site in undamaged condition. Store products out of contact with the ground under weathertight covering, and protect against damage. Do not install damaged units.
1.4 FIELD MEASUREMENT
Dimensions shown are nominal. Field measure openings to obtain exact dimensions needed for fabrication. Meeting rails or stiles of storm (bullet resistant) windows must align with the meeting rails or stiles of the prime windows.
PART 2 PRODUCTS
2.1 MATERIALS
2.1.1 Aluminum
AAMA 1002.
2.1.2 Storm (Bullet Resistant Windows
AAMA 1002, Specification FWE, except as otherwise specified herein.
Provide windows with a Performance Class of 20. Extrusions must have a nominal wall thickness of not less than 0.045 inch.
2.1.3 Sealant
ASTM C920, Type S or M, Grade NS, Class 12.5, use NT, Color Clear.
Sealant must have been tested for use with the materials on which it will be used in this project.
2.2 FABRICATION
AAMA 1002.
2.2.1 Connections
Rigidly connect frames at corners so as to prevent racking during normal handling and installation.
2.2.2 Locks or Latches
On vertically operating inserts, locks must engage round holes or deep notches in the main frame. On horizontally operating inserts, latches must automatically engage a groove or ridge on the main frame or sash.
SECTION 08 51 69.10 Page 2
2.2.3 Access for Cleaning
Inserts, both operating and non-operating, must be removable for cleaning.
Where fixed sashes are indicated, the inserts must be normally fixed but removable for cleaning. Where prime windows have only one operating sash, the operating sash of the storm (bullet resistant) window must be in the same position as the prime window.
2.3 FINISHES
Exposed aluminum surfaces must be factory finished with anodic coating.
New storm windows must have the same finish.
2.3.1 Anodic Coating
Exposed surfaces of aluminum extrusions and sheet must be cleaned and given an anodized finish conforming to AA DAF45. Finish must be clear (natural), designation AA-M10-C22-A31, Architectural Class II, AAMA 611 .
PART 3 EXECUTION
3.1 PREPARATION
Clean, repair, and paint existing prime windows which are to receive storm (bullet resistant) windows before storm (bullet resistant) windows are installed. Examination and repair of weatherstripping and sealant of the prime window is not required. Clean glass and metal surfaces which will be between the storm (bullet resistant) and prime windows with appropriate detergents or cleaning agents. Leave free of dirt, streaks, fingerprints, and other soil.
3.2 INSTALLATION
Install square, in true plane, level, plumb, in alignment with adjacent construction, and in accordance with manufacturer's printed instructions to ensure proper fit, sealing, and operation.
3.2.1 Sealants
Make perimeter of storm (bullet resistant) windows weathertight, except at weep holes. Provide gaskets to separate new metal from existing metal.
3.2.2 Fastening
Holes in the main frame must be oversized to allow for expansion and contraction. Attach units with panhead screws of adequate dimensions for the particular installation.
3.2.3 Drainage
At the storm (bullet resistant) window sill, between main frame and sill, provide weep holes of ample size to drain rainwater collecting between a closed prime window and an open (summer position) storm (bullet resistant) window.
3.3 CLEANING
After installation, clean exposed surfaces to remove foreign matter and surface blemishes. Remove units which cannot be cleaned satisfactorily, SECTION 08 51 69.10 Page 3 and units which are damaged, and provide new units.
-- End of Section --
SECTION 08 51 69.10 Page 4
| DIVISION 08 - OPENINGS |
| 08 34 02 - BULLET-RESISTANT COMPONENTS |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 SYSTEM DESCRIPTION |
| 1.2.1 Design Requirements |
| 1.2.2 Performance Requirements |
| 1.2.3 Submittal Requirement Details |
| 1.3 SUBMITTALS |
| 1.4 QUALITY ASSURANCE |
| 1.5 DELIVERY, STORAGE, AND HANDLING |
| 1.6 SCHEDULING |
| 1.7 WARRANTY |
| PART 2 PRODUCTS |
| 2.1 MATERIALS AND COMPONENTS |
| 2.2 ELECTRICAL WIRING |
| 2.3 BULLET-RESISTANT STEEL WINDOWS |
| 2.3.1 Glazing Materials |
| 2.3.1.1 Laminated Glass |
| 2.3.2 Adhesive Interlayer Materials |
| 2.3.3 Sealants |
| 2.3.4 Deal Trays |
| 2.4 BULLET-RESISTANT SPEAKING APERTURES |
| 2.5 BULLET-RESISTANT GUNPORTS |
| 2.6 BULLET-RESISTANT PASS-THROUGH DRAWER |
| 2.7 ACCESSORIES |
| 2.8 LABELING |
| 2.9 SHOP/FACTORY FINISHING |
| 2.9.1 Ferrous Metal |
| 2.9.2 Galvanizing |
| 2.9.3 Aluminum |
| PART 3 EXECUTION |
| 3.1 EXAMINATION |
| 3.2 FRAMED INSTRUCTIONS |
| 3.3 INSTALLATION |
| 3.4 FASTENERS |
| 3.5 CORROSION PROTECTION - DISSIMILAR MATERIALS |
| 3.6 ELECTRICAL WORK |
| 3.7 ADJUSTING/CLEANING |
| 08 51 69.10 - ALUMINUM STORM BULLET RESISTANT WINDOWS |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 SUBMITTALS |
| 1.2.1 Shop Drawing Information |
| 1.2.2 Product Data Submittal Requirements |
| 1.3 DELIVERY, STORAGE, AND HANDLING |
| 1.4 FIELD MEASUREMENT |
| PART 2 PRODUCTS |
| 2.1 MATERIALS |
| 2.1.1 Aluminum |
| 2.1.2 Storm Bullet Resistant Windows |
| 2.1.3 Sealant |
| 2.2 FABRICATION |
| 2.2.1 Connections |
| 2.2.2 Locks or Latches |
| 2.2.3 Access for Cleaning |
| 2.3 FINISHES |
| 2.3.1 Anodic Coating |
| PART 3 EXECUTION |
| 3.1 PREPARATION |
| 3.2 INSTALLATION |
| 3.2.1 Sealants |
| 3.2.2 Fastening |
| 3.2.3 Drainage |
3.3 CLEANING