N4008524R2535 Amen05 Dwg A-103_60039612_REVISED.pdf

PDF 303 KB Posted

Attached to
Maintenance & Repair Multiple Award Construction Contract (MACC)
Solicitation number
N4008524R2535
Issued by

About this file

This document appears to be a set of drawings and specifications for a roof repair project at Building AS2818 at Marine Corps Base Camp Lejeune in North Carolina. The project involves demolition and replacement of roofing materials including asphalt shingles, flashing, trim, and vapor barrier. New items to be installed include standing seam metal roofing, plywood sheathing, insulation, air/vapor barrier, fascia, and exterior soffit. The drawings provide details on the roof edge, panel clips, and other roof components. This project is likely part of the Maintenance & Repair Multiple Award Construction Contract (MACC) solicitation N4008524R2535 issued by the Department of the Navy Naval Facilities Engineering Command for maintenance and repair construction projects at Marine Corps facilities in North Carolina.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-501

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

A-501

A-103

A-501

TYP.

TYP.

TYP.

TYP.

SEAM CAP

PANEL

CLIP PANEL WITH (2) TWO FASTENERS-TYP. FIX PANELS AT FIRST

PANEL CLIP. REFER TO FIXED PANEL DETAIL FOR PROPER

INSTALLATION.

SEALANT SANDWICHED BETWEEN VERTICAL PANEL LEGS

CONT NEOPRENE FOAM CLOSURE

TURN DOWN PANEL SEAM CAP IN

FIELD

DOUBLE MATERIAL THICKNESS AT EDGE STIFFENER FASTENED

WITH #44-1/8" S.S. RIVETS AT SEAM END CLOSURE

EAVE TRIM WITH HOLD-DOWN CLIP WITH FASTENERS AT 18"

O.C.

EXISTING ROOF SHEATHING (FOR BIDDING PURPOSES REPLACE 10

%) OVER TRUSSES

NEW ITEMS FROM BOTTOM TO TOP: CDX PLYWOOD, INSULATION,

VAPOR/AIR BARRIER (SELF-ADHERING MEMBRANE)

BUILDING ENVELOPE: INSTALL SELF-EXPANDING INSULATION AND

VAPOR/AIR BARRIER TO ENSURE CONTINUITY OF MATERIALS ON

ROOF AND WALL PLANES

SOLID PLASTIC WOOD FASCIA TRIM COMPONENTS

2 x P T CONT CLOSURE TO CONTAIN SELF-EXPANDING INSULATION

5/8" MOIST RESIST GWB-PANT. AND SOLID PLASTIC WOOD TRIM ALL

SIDES. APPLY CONT BEAD OF CAULKING AT ALL DISSIMILAR

MATERIALS

A-103

SUBSTRATE

PANEL, PANEL CLIP, AND FASTENERS

(TWO PER CLIP).

FIX PANELS AT FIRST PANEL CLIP

SEALANT BED SANDWICHED BETWEEN

VERTICAL PANEL LEGS

PANEL CAP

CONT NEOPRENE FOAM CLOSURE

TURN DOWN PANEL SEAM CAPS IN FIELD

SS RIVETS AT SEAM END CLOSURE

DOUBLE MATERIAL THICKNESS AT

EDGE STIFFENER EAVE TRIM. SEE

OTHER DETAILS FOR GUTTER

CONDITIONS WHEN APPLICABLE

EDGE FLASHING, HOLD-DOWN

CLEAT AND FASTENER

X X

SHEET:

80091E1

MARINE CORPS BASE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

CAMP LEJEUNE, NORTH CAROLINA

DESIGN DIR.

SUBMITTED BY:

NAVFAC DRAWING NO.CODE IDENT. NOSIZE

SPEC.SCALE:

SATISFACTORY TO:

APPROVED: PWO OR OICC:

DR.

DES.

CHK.

DATE:

DATE:

OF

1/4"= 1'-0"

ROOF PLAN

A-103

NTS

ROOF EDGE DETAIL

A-103

NTS

ROOF EDGE DETAIL

A-103

ROOF PLAN NOTES

NO. DESCRIPTION DEMOLITION NOTE RENOVATION NOTE

1 ROOFING SYSTEM DEMOLISH ASPHALT SHINGLES, FLASHING, TRIM ITEMS,

VAPOR BARRIER, AND OTHER RELATED ITEMS

STANDING SEAM METAL ROOFING (TYPICAL) PER SPECS AND

DETAILS.

2 SUBSTRATE

AND WOOD BLOCKING

REMOVE ALL UNSUITABLE MATERIALS AS INDICATED IN

THE CONSTRUCTION DOCUMENTS. BRING TO THE

ATTENTION OF THE GOVERNMENT SCOPE OF WORK

DEEMED TO NOT BE INCLUDED.

REPLACE AS NECESSARY (ASSUME 10% FOR BIDDING

PURPOSES)

3 RIDGE DEMO RIDGE ITEMS AND OTHER RELATED ITEMS. PROVIDE RIDGE. SEE DETAIL1/A-501.

4 LOUVERS DEMOLISH LOUVERS, FLASHING, TRIM, AND OTHER

RELATED ITEMS. PROVIDE LOUVERS. SEE DETAIL 3/A-501.

5 VENTS PROTECT VENT AS NECESSARY. DEMOLISH BOOT VENT,

FLASHING, AND OTHER RELATED ITEMS.

PROVIDE VENTS. SEE DETAIL 7/A-501. SEE MECHANICAL FOR

ADDITIONAL NOTES.

6 FASCIA BOARDS

AND TRIM DEMOLISH ALL ITEMS. PROVIDE FASCIA AND TRIM. SEE DETAIL 2/A-103.

7 EXTERIOR SOFFIT DEMOLISH ALL ITEMS. PROVIDE EXTERIOR SOFFIT. SEE DETAIL 2/A-103.

8 GUTTER DEMOLISH ALL ITEMS. PROVIDE GUTTER. INSTALL PER SPECIFICATIONS AND

MANUFACTURER'S RECOMMENDATIONS.

9 DOWNSPOUT DEMOLISH ALL ITEMS. TYPICAL, 3 LOCATIONS.

PROVIDE 3" x 4" DOWNSPOUT (QTY 4) WITH 45 DEGREE

KICKOUT ELBOW AT CONCRETE SIDEWALK. ROUTE

DOWNSPOUT TO ATTACH WITH STRAPS FLUSH TO FACE OF

CMU BLOCK. MIN. 2 STRAPS PER DOWNSPOUT. EMBED

FASTENERS IN MORTAR JOINTS WHERE APPLICABLE.

P

LA

N N

O R

TH

TRUE NORTH

ADDITION OF GUTTERS AND DOWNSPOUTS 04/02/2024 MHH1

ADDITION OF GUTTERS AND DOWNSPOUTS 04/17/2024 MHH2

AutoCAD SHX Text

CONST. CONTR. NO.

AutoCAD SHX Text DISCLOSURE OF INFORMATION CONTRACTOR SHALL COMPLY AS FOLLOWS: A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CON- TRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS: (1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR (2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE. B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE. C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.

AutoCAD SHX Text

FINAL

AutoCAD SHX Text A-103

AutoCAD SHX Text

M. HUNTER

AutoCAD SHX Text

M. HUNTER

AutoCAD SHX Text

K. ROOT, R.A.

AutoCAD SHX Text

M. HUNTER

AutoCAD SHX Text

J. FRANKLIN ORR, P.E.

AutoCAD SHX Text PWO or OICC

AutoCAD SHX Text

BUILDING AS2818

AutoCAD SHX Text

HEAD REPAIRS

AutoCAD SHX Text

ROOF PLAN AND DETAILS

AutoCAD SHX Text 60039612

AutoCAD SHX Text 22-0005

AutoCAD SHX Text

NOTED

AutoCAD SHX Text

NA

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

REVISIONS

Sheets and Views
A-103 ROOF PLAN

File details come from the government source that posted it. Updated .