PPI 2023-10-18 - NAVFAC Response.xlsx
XLSX spreadsheet 20 KB Posted
- Solicitation number
- N4008523R2887
About this file
This document contains responses to questions from potential offerors on a solicitation for the renovation of a laboratory building facility at Naval Station Oceana. The solicitation seeks offers for renovations to Building 603 per the specifications in the Scope of Work located in Volume 1 of the solicitation documents. The Naval Facilities Engineering Command is the contracting agency. Responses were provided to questions on missing drawings, wage determinations, and clarification on fenestration performance requirements in the specifications. The responses clarified where to find the relevant documents and specifications on the System for Award Management and corrected the climate zone referenced for fenestration.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Project Title: Renovate LAB Building Facility, Bldg 603 Oceana | Solicitation / RFP#: N40085-23-R-2887 - PPI Cut Off Date: 10/19/2023 | ||||||||
| PPI No. | Offeror | Date Submitted | REFERENCE | QUESTION | GOVERNMENT RESPONSE | Amend No. | |||
| Page | Section | Para. | Dwg # | ||||||
| 1 | Baron-Rand JV | 10/2/02/2023 | N/A | N/A | N/A | Missing | We have downloaded the project documents and the design drawings are missing. Please provide. | Resolved - Drawings are posted on SAM | |
| 2 | Baron-Rand JV | 10/04/23 | N/A | N/A | N/A | N/A | The General Requirements states that "Attachments" includes Attachment B Wage Determination VA20230167 Dated 01/13/2023. This wage determination is not included in the RFP documenbts. Please provide. | Wage Determination VA20230167 01/13/2023 is posted on SAM | |
| 3 | Baron-Rand JV | 10/04/23 | N/A | N/A | N/A | N/A | The General Requirements states that "Attachments" includes Attachment A Scope of Work. The Attachment A Scope of Work is not included in the RFP documenbts. Please provide. | The SOW is located in the Specifications Volume 1- General Requirements | |
| 4 | Baron-Rand JV | 10/16/23 | 08 51 13 | 1.8.5.1 | Spec section 08 51 13, Aluminum windows, 1.8.5.1 states that this is North-Central climate zone 4 with a U-value of 0.36. This is incorrect, as this project is located within South-Central climate zone 3. International Energy Climate Code (IECC) and ASHRAE, table C402.4 states that U-value requirement for zone 3 is .060 for operable fenestration and 0.46 for fixed fenestration. Please provide clarification. | Use fenestration performance values from ASHRAE 90.1-2016 for climate zone 3A (per ASHRAE 169). | |||
| 5 | |||||||||
| 6 | |||||||||