1582438-Continuation_Sheet-AMEND0001R.pdf

PDF 128 KB Posted

Attached to
New River Ambulatory Care Center/Dental Clinic Replacement
Solicitation number
N4008519R9124
Issued by

About this file

1582438-Continuation_Sheet-AMEND0001R.pdf

View the file

Other files

File Type Posted
Amendment_03.pdf PDF
Amendment_02.pdf PDF
P9838_Price_Proposal_Form_Amendment2.docx DOCX document
1582438-spc1of1-AMEND0001.pdf PDF
Amendment_0001.pdf PDF
Revised_P9838_Price_Proposal_Form.docx DOCX document
1582438spc1of1.pdf PDF
1582438-02of33-CIVIL_1of11.pdf PDF
P9838_RFP.pdf PDF
1582438-01of33-GENERAL_INFO-LIFE_SAFETY.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P-9838 AMBULATORY CARE CENTER / DENTAL CLINIC REPLACEMENT Amendment 0001 e-PROJECT NO.: 1582438

Amend 0001

CONTINUATION SHEET

DOCUMENT 00 01 15 LIST OF DRAWINGS

1.2 CONTRACT DRAWINGS

The following drawings are revised as of July 18. 2019:

NAVFAC Dwg. No. Title

12794495 INDEX OF DRAWINGS - BINDING 1

12794502 LIFE SAFETY SITE PLAN

12794523 BUILDING AS100 SITE DEMOLITION PLAN

12794524 BUILDING AS100 SITE UTILITY DEMOLITION PLAN

12794525 BUILDING AS100 SITE GRADING PLAN-BID ALTERNATE 9

12794526 BUILDING AS100 SITE GRADING PLAN-BID ALTERNATE 4

12794570 WATER AND SEWER UTILITY PLAN

12794571 WATER PROFILES

12794572 SEWER PROFILES

12794577 UTILITY DETAILS

12794591 SITE CONSTRUCTION PHASE VI

12794599 EROSION AND SEDIMENT CONTROL PHASE VI

12794600 TEMPORARY SEWER PROFILE

12794638 INDEX OF DRAWINGS - BINDING 2

12794674 PARTIAL FLOOR PLAN - LEVEL 1 - SECTOR 1

12794675 PARTIAL FLOOR PLAN - LEVEL 1 - SECTOR 2

12794676 PARTIAL FLOOR PLAN - LEVEL 2 - SECTOR 1

12794686 PARTIAL RCP - LEVEL 2 - QUADRANT 1A

12794687 PARTIAL RCP - LEVEL 2 - QUADRANT 1B

12794708 LEAD SHIELDING

12794711 CEILING DETAILS

12794712 METAL FABRICATIONS

12794722 LOG CAT C EQUIPMENT MOUNTING DIAGRAMS

12794734 TYPICAL BRICK DETAILS

12794767 PARTIAL FINISH PLAN - LEVEL 2 - SECTOR 1

12794781 PARTIAL EQUIPMENT PLAN - LEVEL 2 - QUADRANT 1A

12794789 INDEX OF DRAWINGS - BINDING 3

12794790 INDEX OF DRAWINGS - BINDING 3

12794810 PARTIAL PLUMBING FLOOR PLAN - LEVEL 01 - SECTOR 01 - QUADRANT A

12794818 PARTIAL PLUMBING FLOOR PLAN - LEVEL 02 - SECTOR 01 - QUADRANT A

12794822 PARTIAL PLUMBING ROOF PLAN - SECTOR 01

12794863 PARTIAL HVAC FLOOR PLAN - LEVEL 01 - SECTOR 01 - QUADRANT A

12794877 PARTIAL HVAC FLOOR PLAN - LEVEL 02 - SECTOR 01 - QUADRANT A

12794878 PARTIAL HVAC FLOOR PLAN - LEVEL 02 - SECTOR 01 - QUADRANT B

12794881 PARTIAL HVAC ATTIC PLAN - LEVEL 02 - SECTOR 01 - QUADRANT A

12794882 PARTIAL HVAC ATTIC PLAN - LEVEL 02 - SECTOR 01 - QUADRANT B

12794900 PARTIAL PIPING FLOOR PLAN - LEVEL 02 - SECTOR 01 - QUADRANT B

12794904 PARTIAL PIPING ATTIC PLAN - LEVEL 02 - SECTOR 01 - QUADRANT B

12794907 HVAC ENLARGED PLANS

12794911 HVAC SECTIONS

12794925 SCHEDULES - MECHANICAL

12794926 SCHEDULES - MECHANICAL

12794928 SCHEDULES - MECHANICAL

12794931 SCHEDULES - MECHANICAL

12794940 SEQUENCE OF OPERATIONS - VARIABLE VOLUME AIR HANDLING UNIT

12794941 VAV TERMINAL UNIT CONTROLS

NAVFAC Dwg. No. Title

12794974 PARTIAL EQUIPMENT POWER FLOOR PLAN - LEVEL 02 - SECTOR 01 -

QUADRANT A

12794975 PARTIAL EQUIPMENT POWER FLOOR PLAN - LEVEL 02 - SECTOR 01 -

QUADRANT B

12795020 DIAGRAMS & SCHEMATICS - ONE LINE DIAGRAM

These revised Drawings accompany this amendment.

On NAVFAC Dwg. No. 12794720 (AI622)

Under the Logistics Category: A – Contractor Furnished/Installed [CFCI] table, for JSN S1905, Window Sliding

Service, delete 08 51 90 from the Project Spec Section column and replace it with 11 74 00.

PROJECT TABLE OF CONTENTS

The Project Table of Contents is deleted and Project Table of Contents dated July 18, 2019, as shown in the footer, is added to the specifications and accompanies this Amendment.

ATTACHMENT LIST

The Attachment List is deleted and the Attachment List dated July 18, 2019, as shown in the footer, is added to the specifications and accompanies this Amendment.

PROJECT SEAL PAGE

The Seal Page is deleted and Seal Page dated July 18, 2019, as shown in the footer, is added to the specifications and accompanies this Amendment.

Section 00 01 05, List of Drawings is deleted and Section 00 01 05, List of Drawings dated July 18, 2019, as shown in the footer, is added to the Project Table of Contents and accompanies this Amendment.

Section 01 33 00, Submittal Procedures, Submittal Register is deleted and Section 01 33 00, Submittal Procedures, Submittal Register dated July 18, 2019, as shown in the footer, is added to the Project Table of Contents and

Section 01 57 19, Temporary Environmental Controls is deleted and Section 01 57 19, Temporary Environmental

Controls dated July 18, 2019, as shown in the footer, is added to the Project Table of Contents and accompanies this

Amendment.

Section 01 57 19.01 20 Supplemental Temporary Environmental Controls is deleted and Section 01 57 19, Temporary Environmental Controls dated July 18, 2019, as shown in the footer, is added to the Project Table of

Contents and accompanies this Amendment.

Section 01 78 00, Closeout Submittals Attachment: GIS DATA is deleted and Section 01 78 00, Closeout Submittals

Attachment: GIS DATA dated July 18, 2019, as shown in the footer, is added to the Project Table of Contents and

Section 01 91 00.15 22, Total Building Commissioning Attachment: Appendix A is deleted and Section 01 91 00.15

22, Total Building Commissioning Attachment: Appendix A dated July 18, 2019, as shown in the footer, is added to the Project Table of Contents and accompanies this Amendment.

Section 23 64 26, Chilled, Chilled-Hot, and Condenser Water Piping Systems, is deleted and Section 23 64 26, Chilled, Chilled-Hot and Condenser Water Piping Systems, dated July 18, 2019, as shown in the footer, is added to the Project Table of Contents and accompanies this Amendment.

Section 11 74 00, Dental Equipment

2.2.4. a. Provide single faucet capable of reaching all three bowls

After this paragraph, add the following:

2.2.5 S1905 - Window, Sliding Service

A stainless steel (SS) sliding glass transaction window and frame without a screen. Used as a pass thru between two spaces. The key features of the window are the following: It has a single operable lower window and one fixed upper window. The lower window slides open vertically bypassing the fixed upper window. The sliding window when raised remains in position where left. Each windowpane to have 1/4” tempered glass. The operable window must provide a minimum clear opening of 25” width by 23” height. A 27” wide by 14” deep

SS shelf with SS supports is to be included with the window on the clean side of the window. The top of the shelf is to be flush with the clear opening of the window mounted at 34” AFF. No shelf is desired on the decontam side of the window due to necessary adjacent equipment clearances.

--End of Amendment--

File details come from the government source that posted it.