- P193 CONSTRUCT A WATER TREATMENT PLANT REPLACEMENT FACILITY, MARINE CORPS BASE, CHERRY POINT, NORTH CAROLINA
- Solicitation number
- N4008515R0310
About this file
DWG's
View the file
Other files
Show 40 more
Latest 50 of 81 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
20" RW
M
3 4 5
M
M
9 10 11
9 10 11
SUPPLY
RAW WATER
FROM EXISTING
M
"POWER"
"POWER"
"POWER"
"POWER"
MCC
(3)
(3)
(3)
(3)
60101
MCC
MCC
MCC
2 6
2 6
8 12
8 12
"MSC"
DI607A
TO
PRETREATMENT STRAINERS
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:0
A
AE MN
1311985
B L
D G
P -5
U -D I6
A .d g n
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
R A
W W
A T
E R P
U M
P S
T A
T
IO
N
DI601A
NTS
V
V
V
V
120V
1 7
FROM GW WELLS
144 618
JK
12697125
80CP01
40PLC01
BOOSTER PUMP 1
RAW WATER
CS
10PI
10501 10501
10PSL 10PI
11501 11601
BOOSTER PUMP 2
RAW WATER
CS
10PI
10502 10502
10PSL 10PI
11502 11602
11001
10TSH
11002
10TSH
1010501PMP
ON
1010501HS
1010501PMP
RUN
1010502PMP
ON
1010502HS
1010502PMP
RUN
BOOSTER PUMP 3
RAW WATER
CS
10PI
10503 10503
10PSL 10PI
11503 11603
11003
10TSH
1010503PMP
ON
1010503HS
1010503PMP
RUN
BOOSTER PUMP 4
RAW WATER
CS
10PI
10504 10504
10PSL 10PI
11504 11604
11004
10TSH
1010504PMP
ON
1010504HS
1010504PMP
RUN
14000
10FIT
120V UPS
1014000FIT
FLOW
10CS11001
LR
10HS
11001A
10HS
11001B
LR
10HS
11002A
10HS
11002B
10CS11002
LR
10HS
11003A
10HS
11003B
10CS11003
LR
10HS
11004A
10HS
11004B
10CS11004
REMOTEREMOTE REMOTEREMOTE
14" RW
14" RW
14" RW
14" RW
14" RW
14" RW
14" RW
R W
R W
R W
A1
13000
10PIT
10RW-PMP11001
10RW-PMP11002
10RW-PMP11004
10RW-FE
10RW-PMP11003
1013000PIT
PRESSURE
SS
SS
SS
SS
1010501PSL
LOW
1011601ZS 1011602ZS1010502PSL
LOW
1010503PSL
LOW
1011603ZS 1010504PSL
LOW
1011604ZS
14000
10ZS
10ZS
10ZS
10ZS
C
C
C
C
FAILEDFAILED FAILEDFAILED
R W
R W
20" RW20" RW
R W
10RW-ARV60101
10RW-ARV60102
10RW-ARV60103
10RW-ARV60104
10RW-ARV60105
R W
R W
R W
24" RW
24" RW
HP: 50
HP: 50
HP: 50
HP: 50
1011001TSH
HIGH
1011002TSH
HIGH
1011003TSH
HIGH
1011004TSH
HIGH
14" RW
RPM: 1185
RPM: 1185
RPM: 1185
RPM: 1185
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
R
E
C O
R P
IR
A T
IO
N C
H E
R R
Y
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
IP
R
H
R O
L
IN
A L
A F
A Y
E T
M P
L E
X
R F
O L
K
V
IR
G
IN
IA
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
D
P A
R T
M E
F
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
L
C
IL
IT
IE
G
IN
E E
R
G
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
C. ALLAN BAMFORTH, JR.,
NORFOLK, VIRGINIA
3120 Highwoods Blvd, Suite 214
Raleigh, NC 27604
Tel: 919-875-4311
License Number F-0699
15729
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
J
M M
M
M
DI607A
FROM FLOWMETER AND
60701 60201
60202
60203
60204
2 3
60209
4 5
4 5
DI604A
DI603A
DI603A
DI603A
DI604A
TO MEMBRANE
BYPASS FILTER 2
PRETREATMENT STRAINERS
TO MEMBRANE BYPASS
FILTER 1 BACKWASH FLOW CONTROL
TO MEMBRANE BYPASS
FILTER 1 BACKWASH FLOW CONTROL
TO MEMBRANE BYPASS
FILTER 1 BACKWASH FLOW CONTROL
60604DI606A
60605DI606A
60606DI606A
FILTER 2
FROM MEMBRANE BYPASS
FILTER AIR SCOUR
FROM MEMBRANE BYPASS
FILTER AIR SCOUR
FROM MEMBRANE BYPASS
FILTER AIR SCOUR
20LCP23000
DRAWING DI603A
CONTINUED ON
60303DI603A
TO/ FROM MEMBRANE BYPASS
FILTER 1 BACKWASH FLOW CONTROL
60302DI603A
TO/ FROM MEMBRANE BYPASS
FILTER 1 BACKWASH FLOW CONTROL
60304DI603A
TO/ FROM MEMBRANE BYPASS
FILTER 1 BACKWASH FLOW CONTROL
(2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2)
(3 CELLS)
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:0
B L
D G
P -5
U -D I6
A .d g n
B Y
P A
S S F
IL
T E
R
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
M E
M B
R A
N E
DI602A
6 7
120V DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK
145 618
JK
12697126
80CP01
40PLC01
20ZS
21501
OC LR
20HS
21501A
OSC
20HS
21501B
20ZS
22001
OC
120V
LR
20HS
22001A
OSC
20HS
22001B
20PI
23601
20PI
23701
A1
20FIT
21201
120V
LR
20HS
21001A
OSC
20HS
21001B
20ZIT
21001
20701
20PIT
2020701PIT
PRESSURE
20ZS
22501
OC LR
20HS
22501A
OSC
20HS
22501B
120V
120V
120V
20ZS
24001
OC LR
20HS
24001A
OSC
20HS
24001B
120V
20ZS
24501
OC LR
20HS
24501A
OSC
20HS
24501B
20ZS
25001
OC LR
20HS
25001A
OSC
20HS
25001B
120V
FBW
FBW
FBW
21401
20PIT
20FMB-FV
20MB-FV
20MB-FE
20MB-FV
20MB-FCV
20FMB-FV
20MB-FV
20FMB-FV
20MB-FLT23001
MEMBRANE BYPASS
FILTER 1
21501 21201 21001
22001
24001
25001
24501
22501
MB
MB
MB
2" DR
2" DR
2" DR
4" MB
10" MB
4" MB
4" MB
MB/FBW
MB/FBW
MB/FBW
FBS/FTW
FBS/FTW
FBS/FTW
FBS/RTW
FBS/RTW FMB
FMB
FMB
FMBFBS/RTW
23501
20PDIT
120V
M B
ALP
ALP
ALPALP
ALP
ALP
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
60201 60301
M
60202
60203
60505
M
FROM MEMBRANE
FROM MEMBRANE
FROM MEMBRANE
DI602A
DI602A
DI602A
DI605A
DI628A
BYPASS FILTER 1
BYPASS FILTER 1
BYPASS FILTER 1
20LCP23000
DRAWING DI604A
CONTINUED ON
DRAWING DI602A
CONTINUED FROM
M
60501DI605A
FROM MEMBRANE BYPASS
(2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2)
60302 DI602A
BYPASS FILTER 1
60303 DI602A
60304 DI602A
TO/ FROM MEMBRANE
TO/ FROM MEMBRANE
TO/ FROM MEMBRANEFROM MEMBRANE BYPASS
FILTER 2 BACKWASH FLOW CONTROL
FILTER 2 BACKWASH FLOW CONTROL
TO BACKWASH WASTE
PUMP STATION
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:3
B L
D G
P -5
U -D I6
A .d g n
B A
C K
W A
S H F
L O
W C
O N
T R
O L
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
M E
M B
R A
N E B
Y P
A S
S F
IL
T E
R
DI603A
146 618
JK
12697127
80CP01
40PLC01
20ZS
30501
OC LR
20HS
30501A
OSC
20HS
30501B
20ZS
31001
OC
120V
LR
20HS
31001A
OSC
20HS
31001B
20ZS
31501
OC LR
20HS
31501A
OSC
20HS
31501B
120V
120V
20ZS
33501
OC LR
20HS
33501A
OSC
20HS
33501B
120V
20ZS
34001
OC LR
20HS
34001A
OSC
20HS
34001B
120V
20ZS
34501
OC LR
20HS
34501A
OSC
20HS
34501B
120V
FBW
FBW
FBW
20FBW-FV
20FBW-FV
20FBW-FV
30501
31001
31501
34001
33501
34501
20ZS
33000
OC
LR
20HS
33000A
OSC
20HS
33000B
V
33000
FBW
FBW/FTW
FBS/FTW
F T
W
FBS/FTW
FBS/FTW
FBS/FTW
20FBS/FTW-FV
20FBS/FTW-FV
20FBS/FTW-FV
20FTW-FV
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
DI602A 60209 60401
60402
60403
60408
2 3
4 5
4 5
DI605A
DI605A
DI605A
DI620A
PUMP STATION
TO TRANSFER
FROM MEMBRANE
BYPASS FILTER 1
TO MEMBRANE BYPASS
FILTER 2 BACKWASH FLOW CONTROL
TO MEMBRANE BYPASS
FILTER 2 BACKWASH FLOW CONTROL
TO MEMBRANE BYPASS
FILTER 2 BACKWASH FLOW CONTROL
"MSC"
60504DI605A
TO/ FROM MEMBRANE BYPASS
FILTER 2 BACKWASH FLOW CONTROL
60503DI605A
TO/ FROM MEMBRANE BYPASS
FILTER 2 BACKWASH FLOW CONTROL
60502DI605A
TO/ FROM MEMBRANE BYPASS
FILTER 2 BACKWASH FLOW CONTROL
60601DI606A
60602DI606A
60603DI606A
FILTER AIR SCOUR
FROM MEMBRANE BYPASS
FILTER AIR SCOUR
FROM MEMBRANE BYPASS
FILTER AIR SCOUR
DRAWING DI605A
CONTINUED ON
20LCP23000
DRAWING DI603A
CONTINUED FROM
60204DI602A
FILTER 1
(2)(2) (2)(2) (2)(2) (2)(2) (2)(2) (2)(2)
M
M
M M
M
M
M
M
20ACP01
DR
(3 CELLS)
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:1
B L
D G
P -5
U -D I6
A .d g n
B Y
P A
S S F
IL
T E
R
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
M E
M B
R A
N E
DI604A
120V 120V UPS
60404 DI607A
TO CARTRIDGE
FILTERS
JK
147 618
12697128
80CP01
40PLC01
20ZS
21502
OC LR
20HS
21502A
OSC
20HS
21502B
4" MB
20ZS
22002
OC
120V
LR
20HS
22002A
OSC
20HS
22002B
20PI
23602
20PI
23702
A1
20FIT
21202
120V
LR
20HS
21002A
OSC
20HS
21002B
20ZIT
21002
20ZS
22502
OC LR
20HS
22502A
OSC
20HS
22502B
120V
120V
120V
20ZS
24002
OC LR
20HS
24002A
OSC
20HS
24002B
120V
20ZS
24502
OC LR
20HS
24502A
OSC
20HS
24502B
20ZS
25002
OC LR
20HS
25002A
OSC
20HS
25002B
120V
20AE
26500
FCL
26500
FCL
20AIT
FBW
FBW
FBW
21402
20PIT
20FMB-FV
20MB-FV
20MB-FE
20MB-FV
20MB-FCV
20FMB-FV
20MB-FV
20FMB-FV
MEMBRANE BYPASS
FILTER 2
21502 21002
22002
24002
25002
24502
22502
2026500AIT
21202
A1
MB
MB
MB
26400
20FMB-FI
20MB-FLT23002
CHLORINE
FMB
FMB
FMB
FMB
MB/FBW
MB/FBW
MB/FBW
FBS/FTW
FBS/FTW
FBS/FTW
FBS/FTW
FBS/FTW
FBS/FTW
120V
20PDIT
23502
ALP
ALP
ALP
ALP
ALP
ALP
12" FMB
F
M B
F
M B -A
R V
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
60401 60501
M
60402
60403
62002
M
FROM MEMBRANE
FROM MEMBRANE
FROM MEMBRANE
DI604A
DI604A
DI604A
DI620A
DI603A
BYPASS FILTER 2
BYPASS FILTER 2
BYPASS FILTER 2
FROM
TRANSFER PUMP STATION
20LCP23000
DRAWING DI604A
CONTINUED FROM
DRAWING DI606A
CONTINUED ON
(2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2)
60505 DI603A
60502 DI604A
BYPASS FILTER 2
60503 DI604A
60504 DI604A
TO/ FROM MEMBRANE
TO/ FROM MEMBRANE
TO/ FROM MEMBRANE
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:4
B L
D G
P -5
U -D I6
A .d g n
B A
C K
W A
S H F
L O
W C
O N
T R
O L
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
M E
M B
R A
N E B
Y P
A S
S F
IL
T E
R
DI605A
148 618
12697129
80CP01
40PLC01
20ZS
30502
OC LR
20HS
30502A
OSC
20HS
30502B
20ZS
31002
OC
120V
LR
20HS
31002A
OSC
20HS
31002B
20ZS
31502
OC LR
20HS
31502A
OSC
20HS
31502B
120V
120V
20ZS
33502
OC LR
20HS
33502A
OSC
20HS
33502B
120V
20ZS
34002
OC LR
20HS
34002A
OSC
20HS
34002B
120V
20ZS
34502
OC LR
20HS
34502A
OSC
20HS
34502B
120V
FBW
FBW
FBW
FBW
20FBW-FV
20FBW-FV
20FBW-FV
33502
34502
34002
30502
31502
31002
8" FBS
FBS/FTW
FBS/FTW
FBS/FTW
20FBS/FTW-FV
20FBS/FTW-FV
20FBS/FTW-FV
FBS/FTW
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
M
M
60604 DI602A
20LCP23000
DRAWING DI605A
CONTINUED FROM
(2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2)
TO MEMBRANE BYPASS FILTER 1
(BACKWASH AIR SCOUR)
60605 DI602A
60606 DI602A
60601 DI604A
TO MEMBRANE BYPASS FILTER 2
60602 DI604A
60603 DI604A
(BACKWASH AIR SCOUR)
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:2
B L
D G
P -5
U -D I6
A .d g n
A
IR
S
C O
U R
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
M E
M B
R A
N E B
Y P
A S
S F
IL
T E
R
DI606A
"FAIL""START"
149 618
12697130
80CP01
40PLC01
20ZS
40502
OC LR
20HS
40502A
OSC
20HS
40502B
20ZS
41002
OC
120V
LR
20HS
41002A
OSC
20HS
41002B
20ZS
41502
OC LR
20HS
41502A
OSC
20HS
41502B
120V
120V
20ZS
40501
OC LR
20HS
40501A
OSC
20HS
40501B
120V
20ZS
41001
OC LR
20HS
41001A
OSC
20HS
41001B
120V
20ZS
41501
OC LR
20HS
41501A
OSC
20HS
41501B
120V
40502
41502
41002
40501
41001
41501
ALP
ALP
ALP
ALP
ALP
ALP
ALP
ALP
ALP
ALP
ALP
ALP
ALP
20ALP-BLW40000
AIR SCOUR
BLOWER
480V
HP: 15
RPM: 1800
20ALP-FV
20ALP-FV
20ALP-FV
20ALP-FV
20ALP-FV
20ALP-FV
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
PIPE (TYPICAL)
PVC STAND
TO BACKWASH
WASTE TANK
FROM RAW WATER
60101
60702
60703
M
M
PACKAGE SYSTEM
DI601A
DI628A
DI608A
2.
1.
TO MEMBRANE
60701 DI602A
BYPASS FILTERS
63601 DI637A
FROM SODIUM
CARTRIDGE FILTERS
TO MEMBRANE FEED
HYPOCHLORITE FEED PUMPS
10LCP31000
(2) (2) (2) (2)
(2)(2)
GENERAL SHEET NOTES
EXTERNAL INTERFACE TERMINAL STRIPS.
PRE-WIRE ALL POWER AND SIGNAL WIRING TO
UNLESS NOTED OTHERWISE.
PROVIDED BY THE PACKAGE SYSTEM SUPPLIER
PACKAGE SYSTEM BOUNDARY SHALL BE
ALL ITEMS SHOWN WITHIN THE STRAINER
480V
"POWER"
"POWER"
"POWER"
CLOSED"
"OPENED/
"REMOTE"
CLOSE"
"OPEN/
CLOSED"
"OPENED/
"REMOTE"
CLOSE"
"OPEN/
CLOSED"
"OPENED/
"REMOTE"
CLOSE"
"OPEN/
PUMP STATION
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:0
B L
D G
P -5
U -D I6
A .d g n
P R
E T
R E
A T
M E
N T S
T R
A
IN
E R
S
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
F L
O W
M E
T E
R A
N D
61002DI610A
FROM EXISTING
COMPRESSED AIR RECEIVER
120V
120V
120V
120V
120V
120V
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK
10CFI-ARV31601
10CFI-ARV31602
10CFI-ARV31603
60404 DI604A
FROM BYPASS
FILTERS
150 618
JK
12697131
80CP01
20" RW
6" BWW
3" BWW
24" CFI
10RW-STR31002
10RW-STR31001
40PLC01
LR
10HS
31001A
SS
10HS
31001B
HP:
RPM:
HP:
HP:
RPM:
RPM:
LR
10HS
31002A
SS
10HS
31002B
LR
10HS
31003A
SS
10HS
31003B
14" RW
14" RW
10ZS
31501
OC LR
10HS
31501A
OSC
10HS
31501B
10ZS
31502
OC LR
10HS
31502A
OSC
10HS
31502B
10ZS
31503
OC LR
10HS
31503A
OSC
10HS
31503B
14" CFI
14" CFI
14" CFI
C F I
24" RW24" RW
14" RW
1/4" SHC
3" BWW
10RW-STR31003
3" BWW
3" BWW
10FSH
35000
10YL
35000 35000
10YA
HORN
1035000FSH
FLOW
120V
CS
CS
CS
10BWW-FV
31501
120V
10BWW-FV
31502
120V
10BWW-FV
31503
120V
B W
W
STRAINER 2
STRAINER 3
STRAINER 1
R W
1" AHP
10PDIT
30500
10PIT
30500A
10PIT
30500B
R W
3" BWW
FC
FC
FC
C F I
D R
10" FMB
C F I
30" MB
M B
M B
12" MB
M B
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
MIXER
PLATE
FROM SULFURIC ACID
STORAGE AND FEED
FROM SCALE INHIBITOR
STORAGE AND FEED
63301
63201
60703
60801
FROM
PRETREATMENT STRAINERS
1.
TO MEMBRANE
FEED PUMPS
DI633A
DI632A
DI607A
DI609A
MCC
"POWER"
(3)
MCC
(3)
1 2 3
1 2 3
M
"MSC"
3" DR
3" DR
3" DR
3" V
NOTE 5
3" V
NOTE 5
3" V
NOTE 5
TO INJECTION POINT INSIDE OF 2" PVC CARRIER CONDUIT.
1/4" OUTER DIAMETER AND 3/16" INNER DIAMETER TUBING ROUTED
M
"POWER"
M
2. PROVIDE FRP SINK FOR SAMPLE LINE AND DRAIN.
3. SAMPLE TAP DESIGNED FOR USE WITH PORTABLE SDI METER.
4.
5. PIPE VENT AND DRAINS TO PIPE TRENCH.
NOTE 5
"MSC" "MSC" "MSC"
40ACP01
SHEET KEYNOTES
120V UPS
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:1
B L
D G
P -5
U -D I6
A .d g n
C A
R T
R
ID
G E F
IL
T E
R S
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
M E
M B
R A
N E F
E E
D
DI608A
GUARD
SPLASH
JK
INCLUDE PIPING AND PIPING COMPONENTS.
IN ACCORDANCE WITH SPECIFICATION 43 32 56, 2.7, a AND TO
PORTABLE SDI METER PROVIDED BY MEMBRANE SYSTEM SUPPLIER
151 618
12697132
40CP01
40PLC01
40PI
13501
40PI
14501
14" MF
40PI
13502
40PI
14502
14" MF
40PI
13503
40PI
14503
14" MF
14" CFI
CARTRIDGE
FILTER 1
CARTRIDGE
FILTER 2
CARTRIDGE
FILTER 3
MEMBRANE FEED
CS
2" CFI
40PI
11501
1/4" SI
40CFI-V14001
40CFI-V14002
40CFI-V14003
40CFI-PMP11001
DIFF
4012500PDIT 4015800AIT
LR
40HS
11001A
SS
40HS
11001B
4011001PMP
ON
4011001HS
REMOTE
4011001PMP
RUN
MEMBRANE FEED
CS
40PI
11502
40CFI-PMP11002
LR
40HS
11002A
SS
40HS
11002B
SIDESTREAM PUMP 2
SIDESTREAM PUMP 1
4011002PMP
ON
4011002HS
REMOTE
4011002PMP
RUN
14" CFI
14" CFIA1
40FIT
12000
120V UPS
FLOW
4012000FIT
12000
40CFI-FE
1/2" SI
1/2" SU
pH
40AIT
16200 pH
40AE
16200 A1
40CFI-FI
COND
40AIT
16600
COND
40AE
16600 A1
16500
40CFI-FI
TURB
40AIT
15800
TURB
40AE
15800 A1
15700
40CFI-FI
40PI
15600
16100
12700
TURBIDITY
4016200AIT
PH
4016600AIT
CONDUCTIVITY
15500
4015500AIT
40PIT
PRESSURE
40CS11002
24" CFI
40CS11001
4012700PIT
PRESSURE
40PIT
40PDIT
12500
1/4" SA
C F I
C F I
40YL
17000
120V
HORN
40YA
17000
40FSH
17000
4017000HS
FLOW
M F
C F I
HP: 5
HP: 5
RPM: 1750
RPM: 1750
24" MF
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
TO
M
(3)
"POWER"
(3)
"POWER"
"POWER"
FROM CARTRIDGE
FILTERS
60801
60901
60902
60903
60904
MEMBRANE TRAIN 1
MEMBRANE TRAIN 2
MEMBRANE TRAIN 3
DI608A
DI613A
DI614A
DI615A
DI629A
(3)
M
M
M
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:3
B L
D G
P -5
U -D I6
A .d
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
M E
M B
R A
N E F
E E
D P
U M
P S
T A
T
IO
N
DI609A
TO CONCENTRATE BACKWASH
WASTE CLARIFIER
BLOCK DIAGRAM
SEE NETWORK
TO SCADA NETWORK,
BLOCK DIAGRAM
SEE NETWORK
TO SCADA NETWORK,
BLOCK DIAGRAM
SEE NETWORK
TO SCADA NETWORK,
JK
152 618
12697133
4023000FCV
POSNFBK
4023000HS
REMOTE
4023000FCV
POSNCTL
MEMBRANE
AS
40PI
20501
40PSL
20501
40TSH
21001
40PI
21501
40PSH
21501
MEMBRANE
AS
40PI
20502
40PSL
20502 40PI
21502
40PSH
21502
40TSH
21002
MEMBRANE
AS
40PI
20503
40PSL
20503 40PI
21503
40PSH
21503
40TSH
21003
480V
LR
40HS
23000A
OSC
40HS
23000B
40ZIT
23000
12" MF 12" MF
12" MF
12" MF12" MF
12" MF
40HS
21001A
40HS
21001B
40HS
21002A
40HS
21002B
40HS
21003A
40HS
21003B
40AFD21001
40CS21001
480V
40AFD21002
480V
40CS21002
40AFD21003
40CS21003
480V
10" MF/W10" MF/W
FEED PUMP 3
FEED PUMP 2
FEED PUMP 1
21001
40SHK
21002
40SHK
21003
40SHK
40CP01
40PLC01
40MF/W-FCV
23000
40MF-PMP21001
40MF-PMP21003
40MF-PMP21002
24" MF
LR
LR
LR
SS
SS
SS
40ZS
22001
OC
22001
480V
LR
40HS
22001A
OSC
40HS
22001B
4022001FV
CLOSE
4022001ZS
CLOSED
4022001ZS
OPENED
4022001HS
REMOTE
4022001FV
OPEN
40MF-FV
40ZS
22002
OC
22002
480V
LR
40HS
22002A
OSC
40HS
22002B
40MF-FV
4022002FV
CLOSE
4022002ZS
CLOSED
4022002ZS
OPENED
4022002HS
REMOTE
4022002FV
OPEN
40ZS
22003
OC
22003
480V
LR
40HS
22003A
OSC
40HS
22003B
40MF-FV
4022003FV
CLOSE
4022003ZS
CLOSED
4022003ZS
OPENED
4022003HS
REMOTE
4022003FV
OPEN
M F
M F
HP: 200
HP: 200
HP: 200
RPM: 1775
RPM: 1775
RPM: 1775
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
AIR
AMBIENT
IN
T
E R
C O
O L E
R
A F
T E
R C
O O
L E
R
DRAIN
DRAIN
ATMOSPHERE
VENT TO
AIR
AMBIENT
IN
T
E R
C O
O L E
R
A F
T E
R C
O O
L E
R
DRAIN
DRAIN
DRAIN
ATMOSPHERE
VENT TO
RECEIVER
AIR
FILTER
PARTICULATE
FILTER
PARTICULATE
ATMOSPHERE
VENT TO
DI611A
ON
CONTINUED
MASTER OZOBE CONTROL PANEL (MOCP)
COMPRESSOR NO. 2
START
HMS
02600
HMS
02600
STOP
HMS
02600
HMS
02600
LOSL/R
M
480V
"POWER"
ARC02600
COMPRESSOR NO. 1
AIR
COMPRESSOR NO. 1
START
HMS
02500
HMS
02500
STOP
HMS
02500
HMS
02500
LOSL/R
480V
"POWER"
M
ARC02500
COMPRESSOR NO. 2
AIR
START
HMS
02503
HMS
02503
STOP
HMS
02503
HMS
02503
LOS
L/R
480V
"POWER"
DRYER NO. 1
D-YN
02503
AIR DRYER NO. 1
M-02503
M-02085
NO. 1
EXTRACT FAN
HMS
02603
L/R
208V
"POWER"
D-YL
02603
TRIP
D-YN
02603
RUNNING
EXTRACT FAN NO. 1
02504
TI
02504
TW 02051
PIT
02094
FI
02050
AE
02050
AT
02095
SV
02509
PI
ON
M
S S
S S S
S
AHP
AHP
AHP
AHP
AHP
1 1/2" AHP
1 1/2" AHP
DI611A
61003
DI629A
61001
B L
D G
P -5
U -D I6
A .d
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
A
IR
P
R E
P A
R A
T
IO
N S
Y S
T E
M
DI610A
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:0
61002
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK
153 618
JK
12697134
80CP01
40PLC01
1" AHP
3/4" AHP
A H
P
A H
P
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
ATMOSPHERE
VENT TO
S
DRAIN
S S S S
S
OUTSIDE
VENT TO
OUTSIDE
VENT TO
OUTSIDE
VENT TO
S
ATMOSPHERE
VENT TO
OXYGEN RECEIVER
FILTER
O2 PLANT ROOM
MONITOR
AMBIENT
VESSEL A
ADSORBANT
VESSEL B
ADSORBANT
MASTER OZONE CONTROL PANEL (MOCP)
02514
PT
02513
PI
DI610A
FROM
CONTINUED
02515
TW
02515
TE
02521
PT
02518
PT
02529
PT
02526
PT
HMS
02500
HMS
02500
OFF
PSA NO. 1
AUTO
02538
PT
02557
AE
02557
AT
M-02542
02062
PI
02054
PIT
02070
PI
AIT
02072
O2 120V
AHP AHP
GOX GOX
3/4" GOX 3/4" GOX
DI629A61101
61003DI610A
CONCENTRATE LINE
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:3
B L
D G
P -5
U -D I6
A .d
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
O X
Y G
E N G
E N
E R
A T
O R S
Y S
T E
M
1.
SHEET KEYNOTES
VENTED TO OUTSIDE ATMOSPHERE.
154 618
JK
12697135
80CP01
40PLC01
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
FROM MEMBRANE
40ACP30001
M
M
M
"MSC"
"MSC"
"MSC"
TO CONCENTRATE/
BWW CLARIFIER
CLEANING SYSTEM
TO
1.
1. ROUTE ALL DRAINS TO PIPE TRENCH SUMP.
2.
3.
TEMPORARY HOSE.
PROVIDE VICTAULIC FITTING ON DRAIN TO CONNECT TO
4. PIPE TO PIPE TRENCH.
5.
6. INSTRUMENT IS PANEL MOUNTED ON SAMPLE PANEL.
60901
61301
61302
61303
61304
DI609A
DI619A
DI629A
DI616A
DI619A
DI619A
MEMBRANE TRAIN 1
DECARBONATORS
FROM MEMBRANE
FEED PUMP 1
FROM MEMBRANE
DI614A
M
"POWER"
TO CARRIER
61305 DI642A
WATER PUMPS
3 4 5
(3)
SHEET KEYNOTES
GENERAL SHEET NOTES
TRAIN AND WIRE I/O SHOWN.
PROVIDE REMOTE I/O FIELD PANEL FOR EACH MEMBRANE
5 5
5 5
6 6
480V
61904
CLEANING SYSTEM
61402
TRAIN 2 PERMEATE
VALVES, TYPICAL
BLOCK AND BLEED
MEMBRANE TRAIN PACKAGE SYSTEM
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:2
B L
D G
P -5
U -D I6
A .d
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
M E
M B
R A
N E T
R A
IN
DI613A
2 2
BLIND FLANGES FOR FUTURE ENERGY RECOVERY TURBINE.
(2)(2)
(2)(2)
OPERATORIN FRONT OF THE ACP.
THAT DISPLAYS ARE CLEARLY VISIBLE BY AN
THE ACP AND ON THE SAME RACK AS THE ACP SO
MOUNT ALL PRESSURE INSTRUMENTS ADJACENT TO
JK
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK,
120V UPS
155 618
12697136
DR STAGE 140PI
31001
40PI
31002
12" MF
DR
10" CF
40CP01
STAGE 2
40PI
31401
40PI
32201
40PI
34201
40PIT
30401
40PDIT
30501
40PIT
30501
30501
40FIT
31201
40PDIT
31501
40PIT
31501
31501
40PIT
34401
LR
40HS
34501A
OSC
40HS
34501B
40ZIT
40FIT
32701
40FIT
40AE
34901
COND
40AIT
34901
COND
40AE
32901
COND
40AIT
32901
COND
DR
COND
40AE
32501
COND
40AIT
32501
DR
DR
40PIT
33101
DR
40ZS
33501
OC
480V
LR
40HS
33501A
OSC
40HS
33501B
40PI
4" MC
DR
12" MP
40PIT
33701
4" CPR
40PLC01
10" CCR
40PI
40MF-MB31001
40MF-MB32001
34701
40MC-FE40MC-FCV
40MF-FE
40MP-FV
31201
33501
34701
MEMBRANE TRAIN 1
MEMBRANE TRAIN 1
34501
4033701PIT
PRESSURE
34501
480V
BOOSTER PUMP 1
RPM:
INTERSTAGE
40MP-PMP31101
20" MP
AS
40AFD31101
16" MP
MP
40CS31101
40HS
31101A
LR
40SS
31101B
SS
31101
40SHK
A1
32701
40MP-FE
40PIT
31301
4030401PIT
PRESSURE
4030501PDIT
DIFF PRESS
4030501PIT
PRESSURE
4033501ZS
OPENED
4033501ZS
CLOSED
4033501HS
REMOTE
4033501FV
OPEN
CLOSE
4033501FV 4031301PIT
PRESSURE
4031201FIT
FLOW
4031501PDIT
DIFF PRESS
4031501PIT
PRESSURE
4034401PIT
PRESSURE
4034501ZIT
POSITION
4034501HS
REMOTE
4032501AIT
COND
4032701FIT
FLOW
4034701FIT
FLOW
4032901AIT
COND
4034901AIT
COND
4033101PIT
PRESSURE
4034501HS
POSITION
M P
HP: 25
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
40ACP30002
M
M
M
"MSC"
60902
61401
61402
61403
61404
DI609A
DI629A
DI613A
DI619A
DI619A
NOTE 2
VALVES, TYPICAL
BLOCK AND BLEED
FROM MEMBRANE
FEED PUMP 2
M
"POWER"
3 4 5
3 4 5
(3)
MEMBRANE TRAIN 2
1.
SHEET KEYNOTES
GENERAL SHEET NOTES
TRAIN AND WIRE I/O SHOWN.
PROVIDE REMOTE I/O FIELD PANEL FOR EACH MEMBRANE
480V
5 5
6 6
MEMBRANE TRAIN PACKAGE SYSTEM
61903DI619A
61502DI615A
TRAIN 3 PERMEATE
TO MEMBRANE
TRAIN 1 PERMEATE
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:3
B L
D G
P -5
U -D I6
A .d
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
M E
M B
R A
N E T
R A
IN
DI614A
(2) (2)
(2)(2)
1. ROUTE ALL DRAINS TO PIPE TRENCH SUMP.
2.
3.
TEMPORARY HOSE.
PROVIDE VICTAULIC FITTING ON DRAIN TO CONNECT TO
4. PIPE TO PIPE TRENCH.
5.
6. INSTRUMENT IS PANEL MOUNTED ON SAMPLE PANEL.
BLIND FLANGES FOR FUTURE ENERGY RECOVERY TURBINE.
OPERATOR IN FRONT OF THE ACP.
THAT DISPLAYS ARE CLEARLY VISIBLE BY AN
THE ACP AND ON THE SAME RACK AS THE ACP SO
MOUNT ALL PRESSURE INSTRUMENTS ADJACENT TO
JK
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK,
120V UPS
156 618
12697137
DR STAGE 140PI
31002A
40PI
31002B
12" MF
DR
10" CF
40CP01
STAGE 2
40PI
31402
40PI
32202
40PI
34202
40PIT
30402
40PDIT
30502
40PIT
30502
30502
40FIT
31202
40PDIT
31502
40PIT
31502
31502
40PIT
34402
LR
40HS
34502A
OSC
40HS
34502B
40ZIT
40FIT
32702
40FIT
40AE
34902
COND
40AIT
34902
COND
40AE
32902
COND
40AIT
32902
COND
DR
COND
40AE
32502
COND
40AIT
32502
DR
DR
40PIT
33102
DR
40ZS
33502
OC
480V
LR
40HS
33502A
OSC
40HS
33502B
40PI
4" MC
DR
12" MP
4" CPR
40PLC01
10" CCR
40PI
40MF-MB31002
34702
40MC-FE40MC-FCV
40MF-FE
40MP-FV
MEMBRANE TRAIN 2
MEMBRANE TRAIN 2
34502
480V
BOOSTER PUMP 1
RPM:
INTERSTAGE
16" MP
AS
40AFD31102
12" MP
40CS31102
40HS
31102A
LR
40SS
31102B
SS
31102
40SHK
A1
40MP-FE
40MF-MB32002
40MP-PMP31102
3350232702
34502 34702
31202
4030402PIT
PRESSURE
4030502PDIT
DIFF PRESS
4030502PIT
PRESSURE
4033502ZS
OPENED
4033502ZS
CLOSED
4033502HS
REMOTE
4033502FV
OPEN
CLOSE
4033502FV 4031302PIT
PRESSURE
4031202FIT
FLOW
4031502PDIT
DIFF PRESS
4031502PIT
PRESSURE
4034502HS
POSITION
4034402PIT
PRESSURE
4034502ZIT
POSITION
4034502HS
REMOTE
4032502AIT
COND
4032702FIT
FLOW
4034702FIT
FLOW
4032902AIT
COND
4034902AIT
COND
4033102PIT
PRESSURE
40PIT
31302
M P
HP: 25
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
40ACP30003
M
M
M
"MSC"
60903
61501
61502
61503
61504
DI609A
DI629A
DI614A
DI619A
DI619A
NOTE 2
VALVES, TYPICAL
BLOCK AND BLEED
FROM MEMBRANE
FEED PUMP 3
M
61505 DI619A
3 4 5
(3)
MEMBRANE TRAIN 3
GENERAL SHEET NOTES
TRAIN AND WIRE I/O SHOWN.
PROVIDE REMOTE I/O FIELD PANEL FOR EACH MEMBRANE
SHEET KEYNOTES
1.
480V
5 5
5 5
6 6
MEMBRANE TRAIN PACKAGE SYSTEM
TO MEMBRANE
TRAIN 2 PERMEATE
CLEANING TANK
61902DI619A
CLEANING SYSTEM
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:4
B L
D G
P -5
U -D I6
A .d
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
M E
M B
R A
N E T
R A
IN
DI615A
(2)(2)
"MSC"
(2) (2)
1. ROUTE ALL DRAINS TO PIPE TRENCH SUMP.
2.
3.
TEMPORARY HOSE.
PROVIDE VICTAULIC FITTING ON DRAIN TO CONNECT TO
4. PIPE TO PIPE TRENCH.
5.
6. INSTRUMENT IS PANEL MOUNTED ON SAMPLE PANEL.
BLIND FLANGES FOR FUTURE ENERGY RECOVERY TURBINE.
OPERATOR IN FRONT OF THE ACP.
THAT DISPLAYS ARE CLEARLY VISIBLE BY AN
THE ACP AND ON THE SAME RACK AS THE ACP SO
MOUNT ALL PRESSURE INSTRUMENTS ADJACENT TO
JK
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK,
120V UPS
157 618
12697138
DR STAGE 140PI
31003A
40PI
31003B
12" MF
DR
10" CF
40CP01
STAGE 2
40PI
31403
40PI
32203
40PI
34203
40PIT
30403
40PDIT
30503
40PIT
30503
30503
40FIT
31203
40PDIT
31503
40PIT
31503
31503
40PIT
34403
LR
40HS
34503A
OSC
40HS
34503B
40ZIT
40FIT
32703
40FIT
40AE
34903
COND
40AIT
34903
COND
40AE
32903
COND
40AIT
32903
COND
DR
COND
40AE
32503
COND
40AIT
32503
DR
DR
40PIT
33103
DR
40ZS
33503
OC
480V
LR
40HS
33503A
OSC
40HS
33503B
40PI
4" MC
DR
12" MP
4" CPR
40PLC01
10" CCR
40PI
40MF-MB32003
34703
40MC-FE40MC-FCV
40MF-FE
40MP-FV
MEMBRANE TRAIN 3
MEMBRANE TRAIN 3
34503
480V
BOOSTER PUMP 1
RPM:
INTERSTAGE
12" MP
AS
40AFD3110340CS31103
40HS
31103A
LR
40SS
31103B
SS
31103
40SHK
A1
40MP-FE
40MP-PMP31103
40MF-MB31003
31203
34703
32703 33503
34503
4" PMS
4030403PIT
PRESSURE
4030503PDIT
DIFF PRESS
4030503PIT
PRESSURE
4033503ZS
OPENED
4033503ZS
CLOSED
4033503HS
REMOTE
4033503FV
OPEN
CLOSE
4033503FV 4031303PIT
PRESSURE
4031203FIT
FLOW
4031503PDIT
DIFF PRESS
4031503PIT
PRESSURE
4034503HS
POSITION
4034403PIT
PRESSURE
4034503ZIT
POSITION
4034503HS
REMOTE
4032503AIT
COND
4032703FIT
FLOW
4034703FIT
FLOW
4032903AIT
COND
4034903AIT
COND
4033103PIT
PRESSURE
40PIT
31303
HP: 25
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
PUMP STATION
61601
MCC
"POWER"
FROM
61302
M
"POWER"
MCC
MCC
2 3 4 5
2 3 4 5
7 8
9 10 11
9 10 11
M
M
TO TRANSFER
(3)
(3)
DI620A
DI620A61602
TO TRANSFER
PUMP STATION
MEMBRANE TRAIN 1
(2) (2)
"MSC"
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:5
AE JS
B L
D G
P -5
U -D I6
A .d
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
D E
C A
R B
O N
A T
O R A
N D
DI616A
JK
M
158 618
12697139
80CP01
40PLC01
30ZS
13001
OC
480V
LR
30HS
13001A
OSC
30HS
13001B
3013001FV
CLOSE
3013001ZS
CLOSED
3013001ZS
OPENED
3013001HS
REMOTE
3013001FV
OPEN
14501
30LSH
16501
16" DF
BLOWER 1
30TSH
11001
3011001BLW
ON
3011001TSH
HIGH
3011001HS
REMOTE
3011001BLW
RUN
ALP
ALP
3014501PDISH
3016501LSH
HIGH LEVEL
30ZS
13002
OC
480V
LR
30HS
13002A
OSC
30HS
13002B
14502
16" DF
BLOWER 2
30PDIS
10002
30TSH
11002
ALP
ALP
3011002BLW
ON
3011002TSH
HIGH
3011002HS
REMOTE
3011002BLW
RUN
30LSH
16502
3014502PDISH
30PDIS
10001
3016502LSH
HIGH LEVEL
3013002FV
CLOSE
3013002ZS
CLOSED
3013002ZS
OPENED
3013002HS
REMOTE
3013002FV
OPEN
480V
LR
30HS
18000A
OSC
30HS
18000B
30ZIT
18000
3018000FCV
POSNFBK
3018000HS
REMOTE
3018000FCV
POSNCTL
A1
3019000FIT
FLOW
30FIT
120V UPS
16" DMP
20" DMP
CS
CS
30CS11001
30HS
11001A
LR
30HS
11001B
SS
30CS11002
30HS
11002A
LR
30HS
11002B
SS
30ALP-BLW11001
30ALP-BLW11002
13002
30DF-FV
13001
30DF-FV
30MP-FCV30MP-FE
19000
30DF-TNK16001
30DF-TNK16002
1800019000
DECARBONATOR 1
DECARBONATOR 2
20" DMP
DECARBONATOR
DECARBONATOR
20" MP
HIGH DIFF
HIGH DIFF
6" DC
6" DC
4" DC
4" DC
16" DMP
2" DR
12" MP 12" MP
30PDISH
30PDISH
M P
HP: 25
HP: 25
HIGH
3010001PDIS
HIGH
3010002PDIS
RPM: 1800
RPM: 1800
LR
30HS
17000A
OSC
30HS
17000B
30ZIT
17000
3017000FCV
POSNCTLPOSNFBK
3017000HS
REMOTE
3017000FCV
8" MP
30MP-FCV
17000
480V
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
TRENCH SUMP
TO PIPE
"MSC"
TRENCH SUMP
TO PIPE
M
61303
61901
61902
BACKWASH WASTE CLARIFIER
61505
FROM
61403
61503
61304
61404
61504
MEMBRANE TRAIN 1
MEMBRANE TRAIN 2
MEMBRANE TRAIN 3
FROM
MEMBRANE TRAIN 1
FROM
MEMBRANE TRAIN 2
FROM
MEMBRANE TRAIN 3
10" VENT
TRENCH IS NOT REQUITED TO OPERATE THE VALVE.
VALVE WILL HAVE A REMOTE OPERATOR INSTALLED SUCH THAT ACCESS TO THE
CPR AND CCR LINES WILL HAVE A LOW POINT VENT IN THE PROCESS ROOM TRENCH.
V V
TO
MEMBRANE TRAIN 3
1 2 3
1 2 3
DI613A
DI614A
DI615A
DI613A
DI614A
DI615A
DI615A
DI615A
DI629A
PIPE VENTS TO PROCESS ROOM TRENCH.
"MSC" "MSC"
MCC
(3)
40ACP02
FROM
MEMBRANE TRAIN 3
INJECTION
CIP CHEMICAL
61904
MEMBRANE TRAIN 1
61905
MEMBRANE TRAIN 2
DI614A
SHEET KEYNOTES
1.
2.
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:0
B L
D G
P -5
U -D I6
A .d
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
M E
M B
R A
N E C
L E
A N I
N P
L A
C E
DI619A
120V UPS
4 5
159 618
JK
12697140
40CP01
40PLC01
CLEANING TANK
4" DR
40PI
42100
40PSH
42200
PH
40AE
42400
COND
40AE
42600
40PI
43500
40PI
45500
4" PMS
40TSH
42000
CS
40FIT
43000
8" CF
40ZS
40500
OC
120V
LR
40HS
40500A
OSC
40HS
40500B
4040500FV
CLOSE
4040500ZS
CLOSED
4040500ZS
OPENED
4040500HS
REMOTE
4040500FV
OPEN
10" CS/W
MEMBRANE
MEMBRANE
10" CS/W
10" CF
10" CCR
DR
40CF-FE
40PMS-FV
40CF-TNK41000
LEVEL
4041500LIT
40500
40CF-PMP42000
40CS42000
40HS
42000A
40AIT
42400
40AIT
42600
A1 A1
4042400AIT
PH
4042600AIT
CONDUCTIVITY
120V UPS
43000
4043000FIT
FLOW
4" CPR
4" CPR
12" CF
A1
CCR
CCR
CCR
LR
40HS
42000B
SS
4042000PMP
ON
4042000HS
REMOTE
4042000PMP
RUN
4042000PMP
FAIL
4042000TSH
HIGHTEMP
LOW
4041700LSLL
OO
40HS
41000 41000
40TSK
ON
40YL
41000
41700
40LSL
41400
40LSH
40FSH
46000
FLOW
4046000FSH
40CF-HTR41000
TANK IMMERSION
HEATER
480V
41500
40LIT
HIGH
4042200PSH
42300
40CPR-FI
42500
40CPR-FI
PH COND
10" OF
4" CPR 4" CPR
HORN
46000
40YA
120V
40YL
46000
4041400LSH
HIGH
4041900TIT
TEMPERATURE
40TIT
41900
CLEANING PUMP
10" CF
10" CF
HP: 100
RPM: 1780
10" CF
FILTER
CIP CARTRIDGE
40CF-FLT44000 W
A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
WATER STORAGE
61601
62001
62002
TO FINISHED
60408
63501
FROM SODIUM
M
M
DI616A
DI604A
DI635A
DI623A
DI605A
64201DI642A
61602DI616A
DECARBONATORS
FROM
14" OF
24" V
DECARBONATORS
HYPOCHLORITE FEED
LIQUID LIME FEED
FROM MEMBRANE
BYPASS FILTER 2
(3)
(3)
(3)
62303DI623A
(5)
(3)
(2)
(2)
(3)
(4)
(4)
M
MCC
(3)
5 6 7 8
5 6 7 8
WETWELL
64202DI642A
LIQUID LIME FEED
TANK LEVEL
FINISHED WATER
HIGH-HIGH
SHEET KEYNOTES
1.
CONDUIT.
TUBING ROUTED INSIDE OF 2" PVC CARRIER
1/4" OUTER DIAMETER AND 3/16" INNER DIAMETER
FILTER 2 BACKWASH FLOW CONTROL
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:2
B L
D G
P -5
U -D I6
A .d
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
T R
A N
S F
E R P
U M
P S
T A
T
IO
N
DI620A
14" OF
V
V
V
V
V
(3)
30BDP-ARV21101
"POWER"
"POWER"
"POWER"
30BDP-ARV21102
30BDP-ARV21103
30BDP-ARV21104
30BDP-ARV21105
JK
BLOCK DIAGRAM
SEE NETWORK
TO SCADA NETWORK,
BLOCK DIAGRAM
SEE NETWORK
TO SCADA NETWORK,
BLOCK DIAGRAM
SEE NETWORK
TO SCADA NETWORK,
BLOCK DIAGRAM
SEE NETWORK
TO SCADA NETWORK,
160 618
12697141
PUMP 1
TRANSFER AS
30PI
21201
30HS
21001A
30HS
21001B
PUMP 2
TRANSFER AS
30PI
21202
30HS
21002A
30HS
21002B
20500
30LIT
20100
30LSHH
20500
30LSH
20500
30LSL
20500
30LSLL
30LE
20100
PUMP 3
TRANSFER AS
30PI
21203
30HS
21003A
30HS
21003B
80CP01
40PLC01
30AFD21001
480V
30CS21001
30AFD21002
30CS21002
480V
30AFD21003
30CS21003
480V
3020100LIT
LEVEL
3020500LSHH
HIGHHIGH
3020500LSH
HIGH
3020500LSL
LOW
3020500LSLL
LOWLOW
PUMP 4
TRANSFER AS
30PI
21204
30HS
21004A
30HS
21004B
30CS21004
10" BDP
10" BDP
480V
LR
30HS
24000A
OSC
30HS
24000B
30ZIT
24000
3024000FCV
POSNFBK
3024000HS
REMOTE
3024000FCV
POSNCTL
A1
3025000FIT
FLOW
30FIT
25000
V U
P S
30PIT
25500
3025500PIT
PRESSURE
30FBS-FE 30FBS-FCV
30BDP-PMP21001
30BDP-PMP21002
30BDP-PMP21003
480V
ON
30YL
21001
ON
30YL
21002
ON
30YL
21003
ON
30YL
21004
A1
2400025000
30AFD21004
SHK
SHK
SHK
SHK
30BDP-PMP21004
21301
30ZS
30ZS
21302
30ZS
21303
30ZS
21304
PUMP
CS
30PI
22200
30HS
22000A
30CS22000
ON
30YL
22000
30FBS-PMP22000
30ZS
22300
FILTER BACKWASH
C
C
C
C
C
1/4" SHC
/2 S
H C
12" MP
20" DMP
30HS
21001C
SS
30HS
21002C
SS
30HS
21003C
SS
30HS
21004C
SS
30HS
22000C
SS
LR
LR
LR
LR
LR
30ZS
23000
OC
LR
30HS
23000A
OSC
30HS
23000B
3023000FV
CLOSE
3023000ZS
CLOSED
3023000ZS
OPENED
3023000HS
REMOTE
3023000FV
OPEN
480V
23000
3022000PMP
ON
3022000HS
REMOTE
3022000PMP
RUN
3022300ZS
CLOSED
8" FBS
20" BDP
2" LL
2" LL
6" FBS 8" FBS
M P
30FIT
20200
20200
30MB-FE
3020200FIT
FLOW
30YL
20300
120V
HORN
30YA
20300
30FSH
20300
3020300FSH
FLOW
30FBS-FV
F
B S
B D
P
10" BDP
10" BDP
HP: 30
HP: 30
HP: 30
HP: 30
HP: 20
120V UPS
D R
120V UPS
RPM: 890
RPM: 890
RPM: 890
RPM: 890
RPM: 1770
B D
P
B D
P
A1
12" FMB
10" FMB
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
FROM TRANSFER
DI626A
M62001
64301
62301
DI620A
DI643A
"MSC"
TO
HIGH SERVICE PUMPS
95ACP01
HYDROXIDE FEED
DI620A62303
TRANSFER PUMPS
(4)
STATIC MIXER
SHEET KEYNOTES
1.
INSIDE OF 2" PVC CARRIER CONDUIT.
CHEMICAL TUBING ROUTED TO INJECTION POINT
TANK LEVEL
FINISHED WATER
HIGH-HIGH
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:2
B L
D G
P -5
U -D I6
A .d
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
F
IN
IS
H E
D W
A T
E R S
T O
R A
G E
DI623A
120V
120V
120V
120V (HEATER) 120V UPS
120V
DITCH
TO STORMWATER
DITCH
TO STORMWATER
JK
161 618
12697142
WATER TANK
FINISHED
15500
95LIT
A1
95FIT
14500
120V UPS
80CP01
40PLC01
20" FW
1/4" NA
/2
N A
FCL
95AIT
11000
FCL
11000
95AE
10900
95PI
10500
95AIT
12000
12000
95AE
11900
COND
COND
95AIT
12500
12500
95AE
12400 pH pH
95PI
13500
20" BDP 20" FW
95FW-TNK15000
95FW-FE
14500
95BDP-FI95BDP-FI 95FW-FI
9511000AIT
FCL
9512000AIT
CONDUCTIVITY
9512500AIT
PH
9514500FIT
FLOW
9515500LIT
LEVEL
A1 A1 A1
95LSLL
16000
95LSHH
16300
9516000LSLL
LOWLOW
9516300LSHH
HIGHHIGH
40CP01
40PLC01
8" DR
24" OF
95LI
15500
20" FW
20" FW
95FSH
19000
95YL
19000
95YA
20300
HORN
120V
9519000FSH
FLOW
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
M
M
DI623A
FROM FINISHED
WATER STORAGE
"POWER"
"POWER"
"POWER"
DISTRIBUTION SYSTEM
TO EXISTING
62301
ROOM TRENCH
TO PROCESS
"MSC"
(3)
(3)
(3)
(3)
63801 DI638A
FROM CORROSION
INHIBITOR CHEMICAL FEED
64001 DI640A
FROM FLUORIDE
CHEMICAL FEED
95ACP02
120V UPS
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:0
B L
D G
P -5
U -D I6
A .d
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
H
IG
H S
E R
V
IC
E P
U M
P S
DI626A
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK,
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK,
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK,
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK,
95FW-ARV21101
95FW-ARV21102
95FW-ARV21103
95FW-ARV21104
JK
162 618
12697143
40CP01
40PLC01
AS
20501
95PSL 95PI
21501 21501
AS
20502
95PSL 95PI
21502 21502
21001
95TSH
21002
95TSH
AS
20503
95PSL 95PI
21503 21503
21003
95TSH
AS
20504
95PSL 95PI
21504 21504
21004
95TSH
24000
95FIT
V U
P S
9524000FIT
FLOW
A1
21001
95SHK
14" FW
14" FW 14" FW
14" FW
14" FW14" FW
F
W F
W
F
W F
W
95HS
21001A
95AFD21001
95CS21001
480V
21002
95SHK95HS
21002A
95AFD21002
95CS21002
480V
21003
95SHK95HS
21003A
95AFD21003
95CS21003
480V
21004
95SHK95HS
21004A
95AFD21004
95CS21004
480V
PUMP 1
PUMP 2
PUMP 3
PUMP 4
95AE
23500
23000
23500
FCL
95AIT
95PI
22500
FCL
95FW-FE
24000
95FW-PMP21002
95FW-PMP21004
95FW-PMP21001
95FW-PMP21003
95FW-FI
9523500FCL
FCL
HIGH SERVICE
HIGH SERVICE
HIGH SERVICE
HIGH SERVICE
95ZS
95ZS
95ZS
95ZS
14" FW
22000
95PIT
9522000PIT
PRESSURE
1/4" CI
1/4" FL
A1
C
C
C
C
20" FW
LR
LR
LR
LR
95HS
21001B
SS
95HS
21002B
SS
95HS
21003B
SS
95HS
21004B
SS
F
W
95AE
23900
23900
TURB
95AIT
TURB
A1
9523900AIT
FCL
23800
95FW-FI
HP: 125
HP: 125
HP: 125
HP: 125
14" FW
F
W
20" FW18" FW
F
W
F
W
2" FW
20" FW
95FW-PCV
23500
12" FW
F
W
F
W
RPM: 1775
RPM: 1775
RPM: 1775
RPM: 1775
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
TO CONCENTRATE/BACKWASH
WASTE CLARIFIER
PIPE TRENCH SUMP (IN PROCESS ROOM)
WATER
PLANT
FROM
"MSC"
"MSC"
DI629A
DI607A 60702
62801
DI603A 60301
M
(4)
M
(4)
M
SYSTEM
FLOOR DRAIN
PROCESS ROOM
DI641A 64103
FROM LIQUID LIME
HYDROXIDE STORAGE
CONTAINMENT SUMP PUMP
DI634A 63402
FROM SODIUM HYPOCHLORITE
STORAGE CONTAINMENT
SUMP PUMP
DI633A 63302
FROM SULFURIC ACID
DI640A 64002
SUMP PUMP
BACKWASH FLOW CONTROL 1
FROM FLOWMETER AND
STORAGE CONTAINMENT
SUMP PUMP
FROM FLUORIDE
STORAGE CONTAINMENT
"POWER" "POWER" "POWER"
"POWER" "POWER"
1 2
1 2
(4)
"MSC" "MSC" "MSC"
(2)
(2)
(3)
(3)
SHEET KEYNOTES
1.
THE BACKWASH WASTE SUMP.
TREATMENT FILTERS MUST HAVE AN AIR GAP ABOVE
BACKWASH WASTE PIPE FROM MEMBRANE BYPASS
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:0
B L
D G
P -5
U -D I6
A .d g n
P U
M P S
T A
T
IO
N
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
B A
C K
W A
S H W
A S
DI628A
STRAINERS
DRAINS
FILTER BUILDING
FROM BYPASS
PANEL
FILTER SAMPLE
FROM BYPASS
120V
1 2 3
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORKS,
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORKS,
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORKS,
163 618
JK
12697144
80CP01
80PLC01
19200
19200
19200
RPM:
SUMP PUMP 1
CS
RPM:
SUMP PUMP 2
CS
10LIT
20500
10LE
20500
10LSHH
21100
10LSH
21200
22600
10LSLL
22700
10FIT
24000
10PIT
23000
10PSH
23500
40LSHH
40LSH
40LSL
40PI
19700
6" BWW
10LSL
AS
BACKWASH
WASTE PUMP 1
10CS22001
10HS
22001A
10SHK
22001
10AFD22001
480V
AS
BACKWASH
WASTE PUMP 2
10HS
22002A
10SHK
22002
480V
10CS22002
480V
10HS
22003A
10SHK
22003
10CS22003
AS
BACKWASH
WASTE PUMP 3
B W
W
B W
W
B W
W
1021100PMP
HIGHHIGH
1021200PMP
HIGH
1022600PMP
1022700PMP
LOW
LOWLOW
1024000FIT
FLOW
1023000PIT
PRESSURE
40SPD-PMP19501 40SPD-PMP19502
2" SPD
6" BWW6" BWW4" BWW
10AFD22003
10BWW-PMP2200310BWW-PMP2200210BWW-PMP22001
10AFD22002
LRLR LR
10HS
22001B
SS
10HS
22002B
SS
10HS
22003B
SS
10HS
22001C
10HS
22002C
10HS
22003C
RESET RESET RESETON
10YL
22001
ON
10YL
22002
ON
10YL
22003
10USH
22001
10USH
22002
10USH
22003
19200
40LSLL
40LCP19500
4019200LSH
HIGH
4019500PMP
ALARM
A1
1020500LIT
LEVEL
40CP01
40PLC01
1023500PSH
HIGH
V U
P S
8" FBW
480V
120V UPS
10BWW-ARV62801 10BWW-ARV62802 10BWW-ARV62803 1
B W
W -A
R V
3" SPD
3" D
4" D
HP: 3.4 HP: 3.4 HP: 3.4
HP: 0.5 HP: 0.5
A1
RPM: 1650RPM: 1650 RPM: 1650
S
P D -A
R V
40SPD-PE
19700
10BWW-PE
23500
10BWW-PE
23000
10BWW-FE
24000
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
MANHOLE
EXISTING
8" CDW
(EXISTING)
WASTE CLARIFIER
AND BACKAWASH
CONCENTRATE
DECANTER
EXISTING
20" MC/BWW
DI628A
FROM BACKWASH
DI619A
62801
61901
DI615A 61501
DI635A 63501
FEED PUMPS
FROM SODIUM HYPCHLORITE
TRAIN 3
DI614A 61401
TRAIN 2
DI613A 61301
TRAIN 1
WASTE SUMP
CLEAN IN PLACE
61101
FROM AIR/ OXYGEN
GENERATOR SYSTEM
62902 DI630A
TO CLARIFIER WASTE
62901 DI630A
TO CLARIFIER
DECANT PUMP STATION
12" CW
62903 DI630A
TO CLARIFIER
DECANT PUMP STATION
SHEET KEYNOTES
1.
2" PVC CARRIER CONDUIT.
CHEMICAL TUBING ROUTED TO INJECTION POINT INSIDE OF
STATIC MIXER
8" CDW
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:1
B L
D G
P -5
U -D I6
A .d g n
W A
S T
E C
L A
R
IF
IE
R
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
DI629A
DI609A 60904
61101
FROM AIR/ OXYGEN
GENERATOR SYSTEM
DI610A
DECANTER
C O
N C
E N
T R
A T
E A
N D B
A C
K W
A S
H
M
JK
164 618
12697145
4" MC
4" MC
10500
M C
1/4" SHC
80CP01
40PLC01
7012700LSH
HIGH
7012800LSHH
HIGHHIGH
/2 S
H C
6" BWW
40PI
4" MC
10" CS/W
M C
M C
11500 A1
70FIT
11500
LR
70HS
11700A
OSC
70HS
11700B
70ZIT
11700
7011700FCV
POSNFBK
7011700HS
REMOTE
7011700HS
POSNCTL
8" MC 12" MC
6" BWW
7011500FIT
FLOW
40CP01
40PLC01
40PIT
11400
4011400PIT
PRESSURE
10" MF/W
3/4" GOX
1/2" GOX
1/2" GOX/AHP
/2
G O
X /A
H P
11700
8" MC
70GOX/AHP-FCV70GOX/AHP-FE
70LSHH
12800
70LSH
12700
120V UPS
3/4" AHP
120V
40GOX/AHP-PCV
11100 /2
A H
P
40MC-PE
11400
40MC-PE
10500
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
12" CW
FE
FIT
8" CDW
8" CW
DI-629 62902
62903
FROM CLARIFIER
(EXISTING)
PUMP STATION
CLARIFIER WASTE
(EXISTING)
PUMP STATION
CLARIFIER DECANT
OUTFALL
CONCENTRATE
TO
DI629A
(EXISTING)
HEAD OF WWTP
TO
FROM CLARIFIER DECANT
M
1 32 4
70CS22001
(4)
M
70CS22002
M
70CS22003
6 87 9
M
"POWER" "POWER" "POWER"
70AFD24001
"POWER"
70CS24001
(4)
70AFD24002
(4)
70CS24002
62901DI629A
FROM CLARIFIER DECANT
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:4
B L
D G
P -5
U -D I6
A .d g n
D E
C A
N T W
E T
W E
L L
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
C O
N C
E N
T R
A T
E
B A
C K
W A
S H W
A S
DI630A
70AFD22001 70AFD22002
(4)
70AFD22003
(4)
480V 480V 480V 480V 480V
"MSC"
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK,
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK,
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK,
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK,
DIAGRAM
SEE NETWORK BLOCK
TO SCADA NETWORK,
JK
165 618
12697146
FLOW
80CP01
80PLC01
7021000LET
LEVEL
7021500LSLL
LOWLOW
LOW
7021700LSH
HIGH
7021800LSHH
HIGHHIGH
7023000LET
LEVEL
70LSLL
23500
70LSL
23600
70LSH
23700
70LSHH
23800
7023500LSLL
LOWLOW
7023600LSLL
LOW
7023700LSH
HIGH
7023800LSHH
HIGHHIGH
DECANT
PUMP 1
CLARIFIER
70CDW-PMP24001
DECANT
PUMP 2
CLARIFIER
70CDW-PMP24002
7021600LSL
70LSLL
21500
70LSL
21600
70LSH
21700
70LSHH
21800
PUMP 1
70CW-PMP22001
CLARIFIER WASTE
70USH
22101
LR
70HS
22001A
SS
70HS
22001B
70HS
22001C
RESET
ON
70YL
22001
PUMP 2
70CW-PMP22002
CLARIFIER WASTE
70USH
22102
LR
70HS
22002A
SS
70HS
22002B
70HS
22002C
RESET
ON
70YL
22002
PUMP 3
70CW-PMP22003
CLARIFIER WASTE
70USH
22103
LR
70HS
22003A
SS
70HS
22003B
70HS
22003C
RESET
ON
70YL
22003
70USH
24001
LR
70HS
24001A
SS
70HS
24001B
70HS
24001C
RESET
ON
70YL
24001
24001
70SHK
LR
70HS
24002A
SS
70HS
24002B
70HS
24002C
RESET
ON
70YL
24002
24002
70SHK
70USH
24002
AS ASAS AS AS
8" CDW
120V UPS
7024500FIT
FLOW
8" CW
22001
70SHK
22002
70SHK
22003
70SHK
C W
C W
C W
70CDW-ARV63001
70CDW-ARV63002
8" CDW
8" CDW
8" CDW
A1 24500
70CDW-FE
HP: 35HP: 35HP: 35
RPM: 3530RPM: 3530 RPM: 3530 HP: 45 HP: 45
RPM: 1770RPM: 1770
70LET
21000
70LET
23000
70PSH
24101
70PSH
24102
70FIT
24500
70PIT
24600
7024600PIT
PRESSURE
70CDW-PE
24101
70CDW-PE
24102
70CDW-PE
24600
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
SCALE INHIBITOR CONTAINMENT SUMP
CONNECT
QUICK
DI608A63201
METERING PUMP SKID
C
"MSC"
M
M
TO MEMBRANE FEED
CARTRIDGE FILTERS
TOTE
SCALE INHIBITOR
"POWER"
"POWER"
1.
GENERAL SHEET NOTES
SHEET KEYNOTES
1.
WILL HAVE ONLY LONG RADIUS BENDS.
ALL CARRIER CONDUITS CARRYING CHEMICALS
1/4" OUTER DIAMETER AND 3/16" INNER DIAMETER.
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:1
B L
D G
P -5
U -D I6
A .d g n
S T
O R
A G
E A
N D F
E E
D
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
S C
A L E I
N H
IB
IT
DI632A
MCC
1 2 3
M
"POWER"
(3)
1 2 3
1" V 4" V
2.
120V
DR
JK
V
120V
120V
BLANKET
TANK HEAT
SHALL BE HEAT TRACED AND INSULATED.
ALL SI PIPING OUTSIDE THE TREATMENT BUILDING
166 618
12697147
40CP01
40PLC01
RPM:
SCALE INHIBITOR
FEED PUMP 1
51201
40PI
52500
40FSH
CS
51501
RPM:
SCALE INHIBITOR
FEED PUMP 2
51202
40PI
CS
2" SI
/2 S I
40SI-PMP51002
40SI-PMP51001
40SI-PE
40SI-PE
51301
40SI-PE
51302
40SI-PE
51202 51302
5130151201
40LCP51000
120V
LR/SS
40HS
51001A 51001
40SHK
RESET
40HS
51001B
ON
40YL
51001A
40YL
51001B
FAIL
51301
40PLH
40PSH
40PSH
LR/SS
40HS
51002A 51002
40SHK
RESET
40HS
51002B
ON
40YL
51002A
40YL
51002B
FAIL
51302
40PLH
40SI-PCV
40SI-PCV
51502
40FIT
52000
120V UPS
A1
52000
40SI-FE
4051002PMP 4052000FIT
FLOW
40YL
52500
120V
4052500FSH
FLOW
HORN
40YA
52500
/2 S I
4051001PMP
ON
4051001HS
REMOTE
RUN
4051001PMP
4051001DRV
FAIL
ON
4051002PMP
HIGH
4051301PSH
4051002HS
REMOTESPEED
4051001PMP
4051002PMP
RUN
4051001PMP
SC
4051002DRV
FAIL
4051302PSH
HIGH
SPEED
4051002PMP
SC
1/2" SI
HP: 0.3
HP: 0.3
OF
40LP50500
50700
40LI
ON
40YL
50800 50800
40YA
120V
40CS50100
50100A
40HS
LR
50100B
40HS
SS
HORN
TRANSFER PUMP
HP:
RPM:
SCALE INHIBITOR
40SI-PMP50100
50200
40SI-PE
50200
40PI
50600
40LSL
50700
40LIT
50800
40LSH
CS
4050700LI
LEVEL
4050600LSL
LOW
LEVEL
4050700LIT 4050100PMP
ON
4050100HS
REMOTE
RUN
4050100PMP
40SI-TNK50500
SCALE
INHIBITOR
TANK
DR
2" SI
4050800LSH
HIGH
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
CONNECTION
TANK FILL
DI608A63301
CARTRIDGE FILTERS
DI628A63302
WASTE BASIN
1.
TUBING ROUTED INSIDE OF 2" PVC CARRIER CONDUIT.
1/4" OUTER DIAMETER AND 3/16" INNER DIAMETER
2.
METERING PUMP SKID
TO MEMBRANE FEED
M
M
SHEET KEYNOTES
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:0
B L
D G
P -5
U -D I6
A .d g n
S T
O R
A G
E A
N D F
E E
D
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
S U
L F
U R
IC
A
ID
DI633A
4" OF
TO SUMP
TRAP SEAL WITH VEGETABLE OIL.
120V
"POWER"
"POWER"
CYLINDER
DESICCANT
JK
M
167 618
12697148
40CP01
40PLC01
RPM:
FEED PUMP 1
62201
40PI
65001
40FSH
CS
63001
40FIT
64000
SULFURIC ACID
SULFURIC ACID
RPM:
FEED PUMP 2
62202
40PI
CS
SULFURIC ACID
2" SU
2" SPD
40LSH
66500
/2 S
U /2 S
U
/2 S
U
40SU-TNK61000
40SU-PMP62002
40SPD-PMP66000
40SU-PMP62001
4060500LIT
LEVEL
40SU-PCV
40SU-PCV
63002
V U
P S
4064000FIT
FLOW
4065001FSH
FLOW
40SU-PE
62201
40SU-PE
62202
62302
40SU-PE
62302
62301
40SU-PE
62301
4066500LSH
HIGH
40LCP62000
ON
40YL
62001A
FAIL
40YL
62001B
40PLH
62301
4062001PMP
ON
4062001HS
REMOTE
4062001PMP
RUN
4062001DRV
FAIL
4062301PSH
HIGH
4062001PMP
SPEED
4062001PMP
SC
LR/SS
40HS
62001A
40SHK
62001
RESET
40HS
62001B
4062002PMP
ON
4062002HS
REMOTE
4062002PMP
RUN
4062002DRV
FAIL
4062302PSH
HIGH
4062002PMP
SPEED
4062002PMP
SC
ON
40YL
62002A
FAIL
40YL
62002B
40PLH
62302
LR/SS
40HS
62002A
40SHK
62002
RESET
40HS
62002B
40PSH
40PSH
120V 40YL
65001
120V
HORN
40YA
65001
4060500LI
LEVEL
65002
40FSH
4065002FSH
FLOW
40YL
65002
120V
HORN
40YA
65002
2" SPD
DR
40LSH
60600
40LP61000
HIGH
40YL
60600
HORN
4060600LSH
HIGH
40LIT
60500
HP: 0.3
HP: 0.3
STORAGE TANK
40CS66000
66000
SS
40HS
40LSL
66000
120V
SUMP PUMP
SULFURIC ACID
60500
40LI 40YA
60600
RPM: 3450
HP: 0.5
40SU-PE
60600
40SU-PE
60500
40SU-FE
64000 A1
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
A T
IO
N C
H E
R
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
R F
O L
K
V
IR
G
IN
IA
PM/DM
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
Raleigh, NC 27604
Tel: 919-875-4311
E N
IGNE LANOISSEF
O R
P
DESNECIL
O H
ADI FO
E
T A
T S
H C
U
YNAK .D YER
F
F
TO SUMP
CONNECTION
TANK FILL
FILL SINK
TO SODIUM
HYPOCHLORITE FEED
DI635A63401
63602 DI636A
FROM SODIUM HYPOCHLORITE
FEED PUMPS
63504 DI635A
FROM SODIUM HYPOCHLORITE
DI628A63402
WASTE BASIN
"POWER"
M
SHEET KEYNOTES
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:0
:1
O R
A G
E
AE JS
1311985
B L
D G
P -5
U -D I6
A .d g n
IN
S
T R
U M
E N
T A
T
IO
N A
N D C
O N
T R
O L
S O
D
IU
M H
Y P
O C
H L
O R
IT
DI634A
63702 DI637A
FROM SODIUM…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .