5U6500DWG34of43.pdf
PDF 843 KB Posted
- Attached to
- P193 CONSTRUCT A WATER TREATMENT PLANT REPLACEMENT FACILITY, MARINE CORPS BASE, CHERRY POINT, NORTH CAROLINA
- Solicitation number
- N4008515R0310
About this file
DWG's
View the file
Other files
Show 40 more
Latest 50 of 81 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PT39
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:5
:0
A
M
1/4"=1'-0"
GENERATOR AND FUEL STORAGE TANK PLANN
JASDES WS
1311985
B L
D G
P -5
U -D -1
A .d g n
G E
N E
R A
T O
R A
N D F
U E
L S
T O
R A
G E T
A N
K P
L A
N A
N D S
E C
T
IO
N
G E
N E
R A
T O
R
D-190A
A
SECTION
1/4"1'-0"
0 4 8 12
1/4"=1'-0"
LOUVERS
EXHAUST
LOUVERS
INTAKE
RADIATOR
PLENUM
INTAKE
PLENUM
DISCHARGE
LOUVERS
EXHAUST
RADIATOR
39'-6" (REF)
(R
E F
GENERATOR
RISER
14" EXHAUST
RAIN CAP
COUNTERWEIGHTED
SILENCER
EXHAUST
INSULATED
F
O R
F
O S
SHEET KEYNOTES
LADDER
ACCESS
STEEL
6" FILL NOZZLE
F
O S
TRENCH
PIPE
LEVEL GAUGE
MECHANICAL FUEL
NOZZLES
2" SPARE
TANK)
VENT (SECONDARY
10" EMERGENCY
90BWW-GEN10000
90BWW-TNK10000
ENGINE
DIESEL
GENERATOR
RISER
14" EXHAUST
THIMBLE
INSULATED ROOF
28'-7" (REF)
(R
E F
7'-11" (REF)
NOZZLE
6" FILL
4" FOS
90BWW-TNK10000
90BWW-GEN10000
ROOF THIMBLE
INSULATED
EXHAUST PIPING
14" INSULATED
(TYPICAL)
ACCESS DOOR
CABINET
FUEL PORT
(SECONDARY TANK)
2" NORMAL VENT
(PRIMARY TANK)
2" NORMAL VENT
TANK)
VENT (PRIMARY
10" EMERGENCY
DETAIL C2/D801A
PIPE SUPPORT SEE
NOZZLES
2" SPARE
(PRIMARY TANK)
10" EMERGENCY VENT
(SECONDARY TANK)
10" EMERGENCY VENT
90LT
10500
90LT
10500
LADDER
ACCESS
STEEL
90LI
10600
90LI
10600
90XE
12000
90XE
12000
PLENUM
INTAKE
PANEL
CONTROL
GENERATOR
PANEL
CONTROL
GENERATOR
ENGINE/
ENGINE
DIESEL
PLENUM
DISCHARGE
ENCLOSURE
WALK-IN
GENERATOR
1 M E
C H
A N
IC
A L
90BWW-M10000
GENERATOR
DIESEL ENGINE
STORAGE TANK
DIESEL FUEL 2" FOR/4"DWCP
24" ACCESS MANWAY
10000
90FV
SEE C2/D-801A
PIPE SUPPORT
SEE A2/D-590A
PIPE SUPPORT
INSIDE TANK)
2"V676 (ON FOS RISER
2" FOR/4"DWCP
(TYPICAL)
ISOLATORS
VIBRATION 2" FOS/4"DWCP 4"DWCP
2" FOR/
(TYP)
STORAGE TANK
DIESEL FUEL
DETAIL A2/D-590A
PIPE SUPPORT SEE
GENERATOR
DIESEL ENGINE
CONNECTION
FOR PIPING
C1/D-590A
SEE DETAIL
(SECONDARY TANK)
2" NORMAL VENT
(PRIMARY TANK)
2" NORMAL VENT
24" ACCESS MANWAY
ENCLOSURE
WALK-IN
GENERATOR
LEVEL GAUGE
MECHANICAL FUEL
2" FOR/4"DWCP
2" FOS/4"DWCP
2"V752
90FV
10000
2"V752
2" FOS/4"DWCP
TRENCH COVER (TYP)
CHECKERPLATE
AS NOTED
5.
33 52 10 AND 40 05 13.
4. FUEL SYSTEM PIPING AND VALVES PER SECTION
PER SECTION 26 32 13.00 20
3. DIESEL ENGINE GENERATOR AND ACCESSORIES
ACCESSORIES PER SECTION 33 25 10.
2. DIESEL FUEL STORAGE TANK AND
SYSTEMS PER SECTION 05 50 13.
MFRS RECOMMENDATIONS. ANCHORING
1. ANCHOR TO CONCRETE SLAB PER EQUIPMENT
SERVICE, AND MATERIALS OF CONSTRUCTION.
TAG NUMBER, DIMENSIONS, CAPACITY, INTENDED
AS PART OF NOTICE, PROVIDE TANK EQUIPMENT
ISSUING THE RELEASE FOR TANK FABRICATION.
MINIMUM OF 21 CALENDAR DAYS IN ADVANCE OF
TO INSTALL ANY BULK FUEL STORAGE TANK A
WILLIAM.R.POTTER@USMC.MIL) OF THE INTENT
COORDINATOR (WILL POTTER, 252-466-5376,
5. NOTIFY THE MCAS CHERRY POINT STORAGE TANK
A1/D-590A
SEE DETAIL
431 618
12697412
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M
R
IN
E
C
R P
S
IR
A T
IO
N C
H E
R
Y
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
IP
R
H
R O
L
IN
A L
A F
A Y
E T
M P
L E
X
R F
O L
K
V
IR
G
IN
IA
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
D
P A
R T
M E
F
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
L
C
IL
IT
IE
G
IN
E E
R
G
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
C. ALLAN BAMFORTH, JR.,
NORFOLK, VIRGINIA
3120 Highwoods Blvd, Suite 214
Raleigh, NC 27604
Tel: 919-875-4311
License Number F-0699
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
/6 /2
:5
:4
JASHP KBR
1311985
B L
D G
P -5
U -D -5
A .d g n
M E
C H
A N
IC
D-590A
AS SHOWN
E
T A
IL
S
G E
N E
R A
T O
R
A1
NOTES:
TRENCH
CONCRETE
PER STRUCTURAL DRAWINGS
P E
R
D R
A W
IN
G S
S T
R U
C T
U R
A L
TYP
PIPE STRAP,
A2
TRENCH SUPPORT
NTS
"F
O S /4 "D
W C
P
"F
O R /4 "D
W C
P
SUPPORT
1-5/8" PIPE
PRE-ENGINEERED
NOTES:
3. SPACE SUPPORTS 10'-0" OC ALONG TRENCH.
2. FOR TYPE, SIZING, MATERIALS OF CONSTRUCTION SEE SECTION 40 05 13.
SPECIFICATION SECTION 40 05 13.
1. FOR PIPE SUPPORT/FASTENERS MATERIALS OF CONSTRUCTION SEE
(TYP)
4-1/2"
9-3/4"
NTS
DETAIL - ENLARGED VIEW
C1
NTS
CONNECTION
ENGINE
(12" MIN) (TYP)
CONNECTOR
FLEXIBLE PIPE
FILTER
FUEL
2"FOS
2"FOS/4"DWCP 2"FOR/4"DWCP
(TYP)
2"V464
2"FOR
(TYP)
2"V945
1/2" CDR
CDR
1/2"
BUSHING (TYP)
PIPE CLOSURE
CONTAINMENT
DETAIL - ISOMETRIC VIEW
(SEE NOTE 2)
ANCHORS (TYPICAL)
CONCRETE
PROVIDE TWO
(TYP OF 2)
ANGLE BRACKET
PIPE SUPPORT
1.
REMOVAL AT PASSING PIPE LOCATIONS,
NOTCH CHECKER PLATE TO ALLOW
NOTES:
STD. DETAILS)
PLATING (SEE STRUCTURAL
GASKETED CHECKER
REMOVABLE BOLT DOWN/
(TYP)
1/2"V300
COUPLING (TYP)
CONNECT
1/2" QUICK
TRENCH
JOINT
CHECKER PLATE
6"
2"FOS/4"DWCP
2"FOR/4"DWCP
(SEE NOTE 1)
PLATE
INSPECTION
REMOVEABLE
MAX.
SCREW CLAMPS. (TYP)
9/16-INCH TYPE 304 SST
TO PASSING PIPE WITH TWO
SECURE NEOPRENE SHEETS
1/4-INCH NEOPRENE SHEET.
6-INCH LONG WRAPS OF
TRANSITION WITH TWO
AT CHECKER PLATE
PASSING PIPE. SEAL PASSING
PLATE 1/2" LARGER THAN
OPNG IN CHECKERED
432 618
12697413
W A
T E
R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
R
R
IR
A T
IO
N C
H E
R
Y
IN
T
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G C
O M
M A
N D M
ID
A
T L
A N
T
IC
IP
R
R O
L
IN
A L
A F
A Y
E T
M P
L E
X
R F
O L
K
V
IR
G
IN
IA
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
IE
G
IN
E E
R
G
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
ENGINEER-SURVEYOR, LTD.
C. ALLAN BAMFORTH, JR.,
NORFOLK, VIRGINIA
3120 Highwoods Blvd, Suite 214
Raleigh, NC 27604
Tel: 919-875-4311
License Number F-0699
| GENERATOR |
| MECHANICAL |
| PLANS |
| D-190A - GENERATOR AND FUEL STORAGE TANK - PLAN AND SECTION |
| DETAILS |
| D-590A - DETAILS |
| 2015-05-12T18:23:25-0400 | |
| Jarrett A. Selig |
| 2015-05-12T18:25:24-0400 | |
| Jarrett A. Selig |