About this file

DWG's

View the file

Other files

File Type Posted
AMENDMENT_0007.pdf PDF
AMENDMENT_0006.pdf PDF
AMENDMENT_0005.pdf PDF
AMENDMENT_0004.pdf PDF
AMENDMENT_0003.pdf PDF
AMENDMENT_0002.pdf PDF
5U6500DWG6of19.pdf PDF
5U6500DWG13of19.pdf PDF
5U6500DWG11of19.pdf PDF
5U6500DWG16of19.pdf PDF
5U6500DWG1of19.pdf PDF
5U6500DWG12of19.pdf PDF
5U6500DWG3of19.pdf PDF
5U6500DWG2of19.pdf PDF
5U6500DWG19of19.pdf PDF
5U6500DWG5of19.pdf PDF
5U6500DWG14of19.pdf PDF
5U6500DWG17of19.pdf PDF
5U6500DWG18of19.pdf PDF
5U6500DWG9of19.pdf PDF
5U6500DWG15of19.pdf PDF
5U6500DWG7of19.pdf PDF
5U6500DWG10of19.pdf PDF
5U6500DWG8of19.pdf PDF
5U6500DWG4of19.pdf PDF
5U6500DWG41of43.pdf PDF
5U6500DWG37of43.pdf PDF
5U6500DWG38of43.pdf PDF
5U6500DWG40of43.pdf PDF
5U6500DWG35of43.pdf PDF
5U6500DWG36of43.pdf PDF
5U6500DWG39of43.pdf PDF
5U6500DWG34of43.pdf PDF
5U6500DWG43of43.pdf PDF
5U6500DWG28of43.pdf PDF
5U6500DWG25of43.pdf PDF
5U6500DWG31of43.pdf PDF
5U6500DWG29of43.pdf PDF
5U6500DWG30of43.pdf PDF
5U6500DWG24of43.pdf PDF
5U6500DWG33of43.pdf PDF
5U6500DWG26of43.pdf PDF
5U6500DWG27of43.pdf PDF
5U6500DWG32of43.pdf PDF
5U6500DWG16of43.pdf PDF
5U6500DWG12of43.pdf PDF
5U6500DWG22of43.pdf PDF
5U6500DWG23of43.pdf PDF
5U6500DWG19of43.pdf PDF
5U6500DWG11of43.pdf PDF
Show 40 more

Latest 50 of 81 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

506 618

D E

T A

IL

S

JK MN

F

IL

E N

A M

E

P L

O T D

A T

E

P L

O T T

IM

E

/6 /2

:0

:0

A

M

1311985

B L

D G

P -5

U -D I8

A .d g n

IN

S

T R

U M

E N

T A

T

IO

N A

N D C

O N

T R

O L

DI801A

NTS

NOTES:

C3

NTS

A1

NTS

A3

NTS

NOTES:

2 1

WP

WP

PRESSURE INSTRUMENT INSTALLATION - REMOTE MOUNTING PRESSURE INSTRUMENT INSTALLATION - DIAPHRAM SEAL

WELD BY FEMALE NPT BUSHING

SOLVENT WELD REDUCING TEE W/ SOLVENT

TO MECHANICAL SPECIFICATIONS.

TAP, DOUBLE STRAP SADDLE. REFER

2.

1.

ALL CEMENT LINE STEEL PIPE, CAST IRON PIPE, DUCTILE IRON PIPE;

AND PVC AND KYNAR PIPE GREATER THAN 3"

PVC AND KYNAR PIPE 3" AND LESS

PIPE CONNECTION INSTALLATION

C1

NTS

PRESSURE INSTRUMENT INSTALLATION - DIRECT MOUNTING

DIAPHRAGM PRESSURE INSTRUMENT

PRESSURE INSTRUMENT

4 7

2 14

NOTES:

4 7

8 8

7.

6.

5.

4.

3.

2.

1.

8.

7.

6.

5.

4.

3.

2.

1.

9.

8.

7.

6.

5.

4.

3.

2.

1.

12697487

JK

TO PERSONNEL STANDING AT GROUND LEVEL.

GAUGE SHALL BE ANGLED/ POSITIONED SO IT IS EASILY VISIBLE

INSURE PIPE CONNECTION IS HORIZONTALLY ORIENTED.

INSTALL PRESSURE INSTRUMENT IN VERTICAL ORIENTATION.

INSTALLATIONS.

PROVIDE SNUBBER FOR POSITIVE DISPLACEMENT PUMP

D.

C.

B.

A.

TO PERSONNEL STANDING AT GROUND LEVEL.

GAUGE SHALL BE ANGLED/ POSITIONED SO IT IS EASILY VISIBLE

INSURE PIPE CONNECTION IS HORIZONTALLY ORIENTED.

VENTING OF TRAPPED AIR.

INSTALL AT A HIGHER ELEVATION THAN TO ALLOW

INSTALL PRESSURE INSTRUMENTS IN A VERTICAL ORIENTATION .

D.

C.

B.

A.

TO PERSONNEL STANDING AT GROUND LEVEL.

GAUGE SHALL BE ANGLED/ POSITIONED SO IT IS EASILY VISIBLE

INSURE PIPE CONNECTION IS HORIZONTALLY ORIENTED.

VENTING OF TRAPPED AIR.

INSTALL AT A HIGHER ELEVATION THAN TO ALLOW

INSTALL PRESSURE INSTRUMENTS IN A VERTICAL ORIENTATION .

D.

C.

B.

A.

DIAPHRAGM SEAL

WATER PURGE

VENT CHAMBER, TYP

PIPE TO TUBE ADAPTER, TYP

C3 / DI801A

SEE PIPE CONNECTION INSTALLATION DETAIL,

VALVE, TEST TAP / VENT PORT

TUBING

PRESSURE SWITCH (PS)

PRESSURE GAUGE OR TRANSMITTER

TWO-VALVE BLOCK AND BLEED MANIFOLD.

VENT CHAMBER, TYP

PIPE TO TUBE ADAPTER, TYP

C3 / DI801A

SEE PIPE CONNECTION INSTALLATION DETAIL,

VALVE, TEST TAP / VENT PORT

TUBING

PRESSURE SWITCH (PS)

PRESSURE GAUGE OR TRANSMITTER

C3 / DI801A.

SEE PIPE CONNECTION INSTALLATION DETAIL,

PROCESS PIPE.

NIPPLE.

WATER PURGE.

VALVE.

DIAPHRAGM SEAL.

PRESSURE INSTRUMENT.

W A

T E

R T

R E

A T

M E

N T P

L A

N T R

E P

L A

C E

M E

N T

M A

R

C

R P

IR

A T

IO

N C

H E

R R

Y

IN

T

V A

L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G C

O M

M A

N D M

ID

A

T L

A N

T

IC

IP

R

H

R O

L

IN

A L

A F

A Y

E T

M P

L E

X

R F

O L

K

V

IR

G

IN

IA

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

P A

R T

M E

F

V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V

C

IL

IT

IE

G

IN

E E

R

G

M M

A N

D

DES DRW

S Y

M D

E S

C R

IP

T

IO

N D

A T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

ENGINEER-SURVEYOR, LTD.

C. ALLAN BAMFORTH, JR.,

NORFOLK, VIRGINIA

3120 Highwoods Blvd, Suite 214

Raleigh, NC 27604

Tel: 919-875-4311

License Number F-0699

15729

E N

IGNE LANOISSEF

O R

P

DESNECIL

O H

ADI FO

E

T A

T S

H C

U

YNAK .D YER

F

F

J

IL

E N

A M

E

P L

O T D

A T

E

P L

O T T

IM

E

/6 /2

:0

:0

507 618

JK MN

1311985

B L

D G

P -5

U -D I8

A .d g n

IN

S

T R

U M

E N

T A

T

IO

N A

N D C

O N

T R

DI802A

12697488

D E

T A

A1

INDICATOR INSTALLATION

FLOW

C3

NTS

FLOW TRANSMITTER - MAGNETIC

NOTES:

A3

NTS

INSTALLATION FOR VENTED TANK MEASUREMENT

NOTES:

4 4

C1

NTS

5.

4.

3.

2.

1.

(MIN)

PIPE DIA. UNOBSTRUCTED

5 TIMES

(MIN)

PIPE DIA. UNOBSTRUCTED

3 TIMES

PRESSURE DIFFERENTIAL / LEVEL TRANSMITTER

NOTES:

2 4

5.

4.

3.

2.

1.

LEVEL ELEMENT TRANSMITTER

VALVE / INSTRUMENT SUPPORT

FLANGED VALVE, 3" FLANGE

TANK WALL

TANK NOZZLE BY TANK MFR

HYDROSTATIC LEVEL TRANSMITTER

6.

5.

4.

3.

2.

1.

INSURE PIPE CONNECTIONS ARE HORIZONTALLY ORIENTED.

VENTING OF TRAPPED AIR.

INSTALL AT A HIGHER ELEVATION THAN TO ALLOW

INSTALL PRESSURE INSTRUMENTS IN A VERTICAL ORIENTATION .

C.

B.

A.

DIRECTION OF SUN AS MUCH AS POSSIBLE.

MOUNT INSTRUMENT TRANSMITTER SCREEN FACING AWAY FROMA.

MANUFACTURER'S RECOMMENDATIONS.

ENSURE INSTRUMENT IS ADEQUATELY SUPPORTED PER

WITH A MINIMUM OF 12 AWG GROUND WIRE.

TIE GROUND RINGS TO TRANSMITTER EQUIPMENT GROUND

MEASURING ELECTRODES MUST BE IN HORIZONTAL PLANE.

C.

B.

A.

TYPICAL FLOAT TYPE LEVEL SWITCH INSTALLATION

M

IN

M

IN

CABLE CLAMP, SUPPLIED BY MANUFACTURER

QUANTITY OF LEVEL SWITCHES AS SHOWN ON DRAWINGS.

LEVEL SWITCH

ACTIVATION LEVEL AS NOTED.

1" SCHEDULE 80 PVC PIPE

ANCHORS, TYP.

TO BE SECURED TO WALL WITH (2) 3/8" SST CONCRETE

MOUNTING BRACKET, SUPPLIED BY MANUFACTURER,

IN CABLE TO ALLOW FOR SWITCH ACTUATION LEVEL.

TO JUNCTION BOX, PROVIDE MINIMUM OF 1'-0" SLACK

7.

6.

5.

4.

3.

2.

1.

DETAIL C3/DI804A, RESPECTIVELY.

STANCHION MOUNTED DETAIL, C1/DI805A OR WALL-MOUNTED

TRANSMITTER STANCHION OR WALL MOUNTED. SEE

FOUNDATION MOUNTS REQUIRED FOR METERS ABOVE 12".

GROUNDING SHIELD, SEE NOTE B.

REMOVABLE LIFTING LUGS FOR INSTALLING FLOW TUBE.

CABLE TO BE PROVIDED BY INSTRUMENT VENDOR.

THREE-VALVE EQUALIZING MANIFOLD.

C3 / DI801A

SEE PIPE CONNECTION INSTALLATION DETAIL,

VENT CHAMBER

PIPE TO TUBE ADAPTER, TYP

VALVE, TEST TAP / VENT PORT

DIFFERENTIAL PRESSURE TRANSMITTER

W A

T E

R T

R E

A T

M E

N T P

L A

N T R

E P

L A

C E

M E

R

R

A T

IO

N C

H E

R

IN

T

V A

L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G C

O M

M A

N D M

ID

A

T L

A N

T

IC

R

R O

L

IN

A L

A F

A Y

E T

M P

L E

R F

O L

K

V

IR

G

IN

IA

PM/DM

P A

R T

M E

V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V

C

IL

IT

G

IN

E E

R

M M

A N

D

DES DRW

S Y

M D

E S

C R

IP

T

IO

N D

A T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

ENGINEER-SURVEYOR, LTD.

Raleigh, NC 27604

Tel: 919-875-4311

E N

IGNE LANOISSEF

O R

P

DESNECIL

O H

ADI FO

E

T A

T S

H C

U

YNAK .D YER

F

F

E N

A M

E

P L

O T D

A T

E

P L

O T T

IM

E

/6 /2

:0

:5

B L

D G

P -5

U -D I8

A .d g n

IN

S

T R

U M

E N

T A

T

IO

N A

N D C

O N

T R

DI803A

E

T A

LSH

3/16

MIN

LEVEL SWITCH - TUNING FORK WALL MOUNT

6.

5.

4.

3.

3/16

STANCHION MOUNT

5"

3/16

3/16

CONCRETE WALL

NOTES:

2 4

NOTES:

TYPICAL

C3

NTS

7.

6.

5.

4.

3.

2.

1.

6.

5.

4.

3.

2.

1.

PRESSURE OR LEVEL TRANSMITTER

9"

A3

NTS

PRESSURE OR LEVEL TRANSMITTER

NOTES:

C1

NTS

WITH 4" EMBEDMENT.

(2) 1/2" ADHESIVE ANCHORS

SECURE TO WALL WITH

REQUIRED.

SETPOINT ELEVATION AS

SPECIFIED SETPOINT.

LENGTH AS REQUIRED FOR

C6x10.5 CHANNEL

BOLTS & NUTS

9"

CENTERED

/2

2 5

5.

4.

3.

2.

1.

TOP

M

IN WITH 4" EMBEDMENT.

SECURE TO SLAB WITH (2) 1/2" ADHESIVE ANCHORS

MIN 1/2"x8"x8" PLATE, SEE NOTE A.

SETPOINT ELEVATION AS REQUIRED.

LENGTH AS REQUIRED FOR SPECIFIED SETPOINT.

C6x10.5 CHANNEL

BOLTS & NUTS

TOP

SECTION

T Y

P

/2

1" WIDE SLOT

1 1/2"

TYP

ANCHORS WITH 4" EMBEDMENT.

SECURE TO SLAB WITH (4) 1/2" ADHESIVE

1 1/2" NONSHRINK GROUT

PLATE, 1/2"x8"x8"

2" PIPE

WELDED END CAP

BOLTS, NUTS & LOCKWASHERS

FIELD INSTRUMENT AND BRACKET

MOUNTING - STANCHION, INDOOR

ANCHORS WITH 4" EMBEDMENT.

SECURE TO WALL WITH (4) 1/2" ADHESIVE

PLATE, 1/2"x8"x8", TYPICAL

2" PIPE

WELDED END CAP

BOLTS, NUTS & LOCKWASHERS

FIELD INSTRUMENT AND BRACKET

MOUNTING - WALL, INDOOR

SECTION

1 1/4"

TYP

4"

SECTION

1 1/4"

TYP

4"

LEVEL SWITCH - TUNING FORK TOP WALL MOUNT

1" WIDE SLOT

1 1/2"

JK

CORNERS.

ROUND OFF ALL EXPOSED EDGES AND

PAINTING (EXCEPT SST).

ACCORDING TO SPECIFICATIONS FOR

PAINT METAL IN CONTACT WITH CONCRETE

B.

A.

ROUND OFF ALL EXPOSED EDGES AND CORNERS.A.

ROUND OFF ALL EXPOSED EDGES AND CORNERS.

SPECIFICATIONS FOR PAINTING (EXCEPT SST).

PAINT METAL IN CONTACT WITH CONCRETE ACCORDING TO

B.

A.

ROUND OFF ALL EXPOSED EDGES AND CORNERS.

FOR PAINTING (EXCEPT SST).

PAINT METAL IN CONTACT WITH CONCRETE ACCORDING TO SPECIFICATIONS

FLOOR, UNLESS OTHERWISE NOTED.

ALL MOUNTING BRACKETS ARE TO BE INSTALLED APPROXIMATELY 4'-0" ABOVE

C.

B.

A.

508 618

12697489

W A

T E

R T

R E

A T

M E

N T P

L A

N T R

E P

L A

C E

M E

R

R

A T

IO

N C

H E

R

IN

T

V A

L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G C

O M

M A

N D M

ID

A

T L

A N

T

IC

R

R O

L

IN

A L

A F

A Y

E T

M P

L E

R F

O L

K

V

IR

G

IN

IA

PM/DM

P A

R T

M E

V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V

C

IL

IT

G

IN

E E

R

M M

A N

D

DES DRW

S Y

M D

E S

C R

IP

T

IO

N D

A T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

ENGINEER-SURVEYOR, LTD.

Raleigh, NC 27604

Tel: 919-875-4311

License Number F-0699

LSH

E N

IGNE LANOISSEF

O R

P

DESNECIL

O H

ADI FO

E

T A

T S

H C

U

YNAK .D YER

F

F

E N

A M

E

P L

O T D

A T

E

P L

O T T

IM

E

/6 /2

:0

:5

B L

D G

P -5

U -D I8

A .d g n

IN

S

T R

U M

E N

T A

T

IO

N A

N D C

O N

T R

DI804A

E

T A

WALL MOUNTED PANEL OR INSTRUMENT INSTALLATION

9.

8.

7.

6.

5.

4.

3.

2.

1.

NOTES:

TRUCK UNLOADING LEVEL STATION

WELDED END CAP

PRE-ENGINEERED PIPE STRAP AS SPECIFIED

U-BOLT

1/2" ADHESIVE ANCHOR WITH 3 1/2" EMBEDMENT

MOUNTED USING SUPPLIED U-BOLT

2" PIPE

CONCRETE WALL

LEVEL INDICATOR

(OR WORKING HEIGHT)

CHEMICAL, VOLUME, AND CHEMICAL RANGE

1/4" PLATE WITH SIGN DEPICTING: TANK NUMBER,

14"

2"

4.

3.

2.

1.

C1

PRESSURE INSTRUMENT - SENSOR

REMOTE MOUNTED FROM TRANSMITTER

8.

7.

6.

5.

4.

3.

2.

1.

LOCATE CENTER OF INSTRUMENT 4' 6" ABOVE FLOOR.

APPLICATION.

SUNSHIELD ONLY REQUIRED FOR OUTDOOR

WITH 4" EMBEDMENT.

SECURE TO WALL WITH (4) 1/2" ADHESIVE ANCHORS

CONCRETE WALL OR STEEL PLATE.

FLOOR SLAB

ALL SIDES OF THE INSTRUMENT.

SIZED TO EXTEND A MINIMUM OF 1" BEYOND

PROVIDE 1/4" MOUNTING PLATE, ROUND EDGES,

STUD NUT

UNI STRUT

JK

TO SPECIFICATIONS FOR PAINTING (EXCEPT SST).

PAINT METAL IN CONTACT WITH CONCRETE ACCORDING

ROUND OFF ALL EXPOSED EDGES AND CORNERS.

B.

A.

509 618

12697490

SEE PIPE CONNECTION INSTALLATION DETAIL C3/DI801A.

VALVE

PRESSURE INSTRUMENT ("SEPARATE HOUSING")

DETAIL C3/DI8004A, RESPECTIVELY

STANCHION MOUNTED DETAIL, C1/DI805A OR WALL-MOUNTED

TRANSMITTER STANCHION OR WALL MOUNTED. SEE

VENDOR SUPPLIED CABLE TO PRESSURE TRANSMITTER.

W A

T E

R T

R E

A T

M E

N T P

L A

N T R

E P

L A

C E

M E

R

R

A T

IO

N C

H E

R

IN

T

V A

L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G C

O M

M A

N D M

ID

A

T L

A N

T

IC

R

R O

L

IN

A L

A F

A Y

E T

M P

L E

R F

O L

K

V

IR

G

IN

IA

PM/DM

P A

R T

M E

V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V

C

IL

IT

G

IN

E E

R

M M

A N

D

DES DRW

S Y

M D

E S

C R

IP

T

IO

N D

A T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

ENGINEER-SURVEYOR, LTD.

Raleigh, NC 27604

Tel: 919-875-4311

E N

IGNE LANOISSEF

O R

P

DESNECIL

O H

ADI FO

E

T A

T S

H C

U

YNAK .D YER

F

F

T A

IL

S

JK MN

F

IL

E N

A M

E

P L

O T D

A T

E

P L

O T T

IM

E

/6 /2

:0

:0

A

M

1311985

B L

D G

P -5

U -D I8

A .d

T R

U M

E N

T A

T

IO

N A

N D C

O N

T R

DI805A

NOTES:

SINGLE CASE MOUNTED INSTRUMENTS - STANCHION

3/16

IN

S

T R

U M

E N

T

T O S

U

IT

M

IN

2'-0" MIN

6" 6" 6"

2"

/2

M

IN3

A1

NTS

DOUBLE CASE MOUNTED INSTRUMENTS - STANCHION

IN

S

T R

U M

E N

T

T O S

U

IT

M

IN

2'-0" MIN

6" 6"

M

IN3

2-8

2-8SUN SHIELD

HSS TO

1/4

1/4HSS

C6 TO

4"

ROUND EDGES & CORNERS.

INSTRUMENT MOUNTING FOOT.

SUN SHIELD BACK PLATE.

TYP OF 4

3/8" STUD BOLT WITH NUTS AND WASHERS,

TOP & SIDES FORMED OF SINGLE SHEET 14 GA.

TACK WELD TO TOP & SIDES AS REQUIRED.

BACK FORMED OF SINGLE SHEET 10 GA,

1 1/2" NONSHRINK GROUT

WITH 4" EMBEDMENT.

SECURE TO SLAB WITH (4) 1/2" ADHESIVE ANCHORS

PL 1/2"x10"x10"

C6x10.5

INSTRUMENT OR SMALL PANEL.

HSS 2"x1"x3/16" LENGTH TO SUIT INSTRUMENT.

SUN SHIELD ONLY REQUIRED FOR OUTDOOR APPLICATION.

& WASHERS.

INSTRUMENT TO STANCHION W/ BOLTS, NUTS

MOUNTING HOLES TO SUIT INSTRUMENT, SECURE

14.

13.

12.

11.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

3/16

ROUND EDGES & CORNERS.

INSTRUMENT MOUNTING FOOT.

SUN SHIELD BACK PLATE.

TYP OF 4

3/8" STUD BOLT WITH NUTS AND WASHERS,

TOP & SIDES FORMED OF SINGLE SHEET 14 GA.

TACK WELD TO TOP & SIDES AS REQUIRED.

BACK FORMED OF SINGLE SHEET 10 GA,

1 1/2" NONSHRINK GROUT

WITH 4" EMBEDMENT.

SECURE TO SLAB WITH (4) 1/2" ADHESIVE ANCHORS

PL 1/2"x10"x10"

C6x10.5

INSTRUMENT OR SMALL PANEL.

HSS 2"x1"x3/16" LENGTH TO SUIT INSTRUMENT.

SUN SHIELD ONLY REQUIRED FOR OUTDOOR APPLICATION.

& WASHERS.

INSTRUMENT TO STANCHION W/ BOLTS, NUTS

MOUNTING HOLES TO SUIT INSTRUMENT, SECURE

14.

13.

12.

11.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

2-8

2-8SUN SHIELD

HSS TO

1/4

1/4HSS

C6 TO

4"

6"

2"

/2

ORIENT INSTRUMENT MOUNTING STANCHION SO THE OPEN SIDE OF THE SUN SHIELD FACES NORTH.

PAINT METAL IN CONTACT WITH CONCRETE ACCORDING TO SPECIFICATIONS FOR PAINTING (EXCEPT SST).

ROUND OFF ALL EXPOSED EDGES AND CORNERS.

C.

B.

A.

ORIENT INSTRUMENT MOUNTING STANCHION SO THE OPEN SIDE OF THE SUN SHIELD FACES NORTH.

PAINT METAL IN CONTACT WITH CONCRETE ACCORDING TO SPECIFICATIONS FOR PAINTING (EXCEPT SST).

ROUND OFF ALL EXPOSED EDGES AND CORNERS.

C.

B.

A.

12697491

510 618

W A

T E

R T

R E

A T

M E

N T P

L A

N T R

E P

L A

C E

M E

R

R

A T

IO

N C

H E

R

IN

T

V A

L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G C

O M

M A

N D M

ID

A

T L

A N

T

IC

R

R O

L

IN

A L

A F

A Y

E T

M P

L E

R F

O L

K

V

IR

G

IN

IA

PM/DM

P A

R T

M E

V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V

C

IL

IT

G

IN

E E

R

M M

A N

D

DES DRW

S Y

M D

E S

C R

IP

T

IO

N D

A T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

ENGINEER-SURVEYOR, LTD.

Raleigh, NC 27604

Tel: 919-875-4311

E N

IGNE LANOISSEF

O R

P

DESNECIL

O H

ADI FO

E

T A

T S

H C

U

YNAK .D YER

F

F

T A

IL

S

JK MN

F

IL

E N

A M

E

P L

O T D

A T

E

P L

O T T

IM

E

/6 /2

:0

:0

A

M

1311985

B L

D G

P -5

U -D I8

A .d

T R

U M

E N

T A

T

IO

N A

N D C

O N

T R

DI806A

THERMOWELL INSTALLATION

PVC TEE, TYP.

PVC BLIND FLANGE, DRILL & TAP 1" NPT THERMOWELL, TYP.

2.

1.

PVC PIPE

18" MAX

9"

A.

2 3

NEOPRENE GASKET

SST U-BOLT (TYP)

LEVEL TRANSMITTER PROBE

4" PVC STILLING WELL

C6x10.5 (TYP) NOTE A

1" HOLE, TYP

4" PVC SCH. 80 PIPE

4" FLANGE, CARBON STEEL

316 SST BOLTS & NUTS

1 1/2" NPT HALF COUPLING

CABLE MOUNTING SCREW

TO TERMINAL JUNCTION BOX

PROBE (SENSOR) CABLE

13.

12.

11.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

LEVEL TRANSMITTER - SUBMERSIBLE

SAME MATERIAL AND FINISH AS TANK.

PROVIDE 4 EQUALLY SPACED;

FLOW

C3

NTS

THERMOWELL INSTALLATION

SENSOR CABLE TO TRANSMITTER (NOTE A)

UPSTREAM FLANGE CONNECTION

FLANGE MOUNTED CORIOLIS FLOWMETER

DOWNSTREAM FLANGE CONNECTION

FLEXIBLE CONDUIT

5.

4.

3.

2.

1.

NOTES:

MANUFACTURER.

ARE SUPPLIED BY INSTRUMENT

COMPONENTS DESIGNATED BY ( )

INDIVIDUALLY SHIELDED CORES.

CABLE WITH COMMON SHIELD AND

65 FEED FROM FLOWMETER. PVC

LOCATE TRANSMITTER LESS THAN

B.

A.

A3

NTS

SUBMERSIBLE LEVEL ELEMENT INSTALLATION

.8

6"

3/16

3/16

NOTES:

A.

ZERO ELEVATION AS NOTED

SENSOR BODY

STILLING WELL

C6x10.5 SST CHANNEL, 10" LONG

3/4" NPT

SST HALF COUPLING WITH 3/4" NPT CONNECTION

PRESSURE SENSOR CABLE TO JUNCTION BOX

1/4"x8"x8" SST PLATE

SECURE TO WALL WITH 4 - 1/2" SST CONCRETE ANCHORS

STRAIN RELIEF

NYLON CABLE SUPPORT TO 50 PSIG

11.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

BY INSTRUMENT MANUFACTURER.

COMPONENTS DESIGNATED BY ARE SUPPLIED

B.

PRIOR TO INSTALLATION.

TO BE COORDINATED WITH CONTRACTOR AND ENGINEER

PENETRATION THROUGH TOP OF EXISTING PUMP STATION

511 618

12697492

W A

T E

R T

R E

A T

M E

N T P

L A

N T R

E P

L A

C E

M E

R

R

A T

IO

N C

H E

R

IN

T

V A

L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G C

O M

M A

N D M

ID

A

T L

A N

T

IC

R

R O

L

IN

A L

A F

A Y

E T

M P

L E

R F

O L

K

V

IR

G

IN

IA

PM/DM

P A

R T

M E

V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V

C

IL

IT

G

IN

E E

R

M M

A N

D

DES DRW

S Y

M D

E S

C R

IP

T

IO

N D

A T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

ENGINEER-SURVEYOR, LTD.

Raleigh, NC 27604

Tel: 919-875-4311

E N

IGNE LANOISSEF

O R

P

DESNECIL

O H

ADI FO

E

T A

T S

H C

U

YNAK .D YER

F

F

E N

A M

E

P L

O T D

A T

E

P L

O T T

IM

E

/6 /2

:0

:4

512 618

B L

D G

P -5

U -D I8

A .d g n

IN

S

T R

U M

E N

T A

T

IO

N A

N D C

O N

T R

DI807A

12697493

E

T A

INLINE MOUNTING

LEVEL SWITCH - TUNING FORK

TANK MOUNT

L S

H

RETRACTABLE PH/ ORP SENSOR INSTALLATION

3.

2.

1.

JK

NTS

A1

PRESSURE TYPE LEVEL SWITCH - TANK MOUNT

INSTRUMENT SUPPORT

2" FLANGED TANK NOZZLE WITH 1/4" FNPT CONNECTION

PRESSURE SWITCH

3.

2.

1.

LENGTH AS SPECIFIED.

1.5" FLANGED TANK NOZZLE

FLANGE MOUNTED LEVEL SWITCH

A4

NTS

THERMAL MASS FLOW ELEMENT ENSTALLATION

FOR PROCESS AIR SERVICE

FE

CONDUIT, TYP.

NEMA 4X TERMINAL ENCLOSURE

PROCESS PIPE

3/4" THREADOLET SAME MATERIAL AS PROCESS PIPE.

COMPRESSION FITTING

MANUFACTURER'S INSTRUCTIONS.

FLOW DIRECTION ARROW, INSTALL PER

INSERTION LENGTH AS REQUIRED

AND 90° FROM VERTICAL.

INSTALLATION SHOULD BE BETWEEN VERTICAL

8.

7.

6.

5.

4.

3.

2.

1.

INSTALL WITHIN 80 DEGREES OF VERTICAL.

REMOVAL.

TOP OF RETRACTABLE DEVICE FOR PROBE

PROVIDE A MINIMUM OF 1'-2" CLEARANCE ABOVE

B.

A.

DETAIL, C3/DI801A

SEE PIPE CONNECTION INSTALLATION

RETRACTABLE ASSEMBLY

W A

T E

R T

R E

A T

M E

N T P

L A

N T R

E P

L A

C E

M E

R

R

A T

IO

N C

H E

R

IN

T

V A

L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G C

O M

M A

N D M

ID

A

T L

A N

T

IC

R

R O

L

IN

A L

A F

A Y

E T

M P

L E

R F

O L

K

V

IR

G

IN

IA

PM/DM

P A

R T

M E

V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V

C

IL

IT

G

IN

E E

R

M M

A N

D

DES DRW

S Y

M D

E S

C R

IP

T

IO

N D

A T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

ENGINEER-SURVEYOR, LTD.

Raleigh, NC 27604

Tel: 919-875-4311

E N

IGNE LANOISSEF

O R

P

DESNECIL

O H

ADI FO

E

T A

T S

H C

U

YNAK .D YER

F

F

E N

A M

E

P L

O T D

A T

E

P L

O T T

IM

E

/6 /2

:0

:5

B L

D G

P -5

U -D I8

A .d g n

IN

S

T R

U M

E N

T A

T

IO

N A

N D C

O N

T R

DI808A

E

T A

3 1/2 " 1 1/2 " 3 1/2 " 2 "

/4

A1

STANDARD FREESTANDING PANEL MOUNTING

NTS

3 4

OPEN BOTTOM PANEL ENCLOSED BOTTOM PANEL

4.

3.

2.

1.

JK

C1

NTS

OXYGEN MONITOR ELEMENT INSTALLATION

SENSOR

MOUNTING BRACKET

CONCRETE ANCHORS.

SECURE TO WALL WITH 1/4" GALVANIZED

CONDUIT TO ANALYZER/ TRANSMITTER

3 9

6.

5.

4.

3.

2.

1.

CONCRETE DECK

RADAR ANTENNA

ASME B 16.5 ANSI CL 150 8" FLANGE ADAPTER

8" STAINLESS STEEL FLOOR PIPE WITH

NEOPRENE GASKET

8" X 4" FLANGE ADAPTER

STAINLESS STEEL ASME B 16.5 ANSI CL 150

STAINLESS STEEL NUTS AND BOLTS

C3

NTS

LEVEL TRANSMITTER - RADAR

CONCRETE DECK INSTALLATION

1'-0" MIN

8" MAX

A4

NTS

LEVEL TRANSMITTER - RADAR - TANK MOUNT

FLANGE MOUNTED RADAR LEVEL ELEMENT

4" FLANGED TANK NOZZLE

VITON GASKET

316 STAINLESS STEEL BOLTS & NUTS

4.

3.

2.

1.

LET

LET

513 618

12697494

W A

T E

R T

R E

A T

M E

N T P

L A

N T R

E P

L A

C E

M E

R

R

A T

IO

N C

H E

R

IN

T

V A

L F

A C

IL

IT

IE

S E

N G

IN

E E

R

IN

G C

O M

M A

N D M

ID

A

T L

A N

T

IC

R

R O

L

IN

A L

A F

A Y

E T

M P

L E

R F

O L

K

V

IR

G

IN

IA

PM/DM

P A

R T

M E

V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A

V

C

IL

IT

G

IN

E E

R

M M

A N

D

DES DRW

S Y

M D

E S

C R

IP

T

IO

N D

A T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

OF

EPROJECT NO.:

ENGINEER-SURVEYOR, LTD.

Raleigh, NC 27604

Tel: 919-875-4311

E N

IGNE LANOISSEF

O R

P

DESNECIL

O H

ADI FO

E

T A

T S

H C

U

YNAK .D YER

F

F

STANDARD DETAILS
INSTRUMENTATION AND CONTROLS
DI801A - DETAILS
DI802A - DETAILS
DI803A - DETAILS
DI804A - DETAILS
DI805A - DETAILS
DI806A - DETAILS
DI807A - DETAILS
DI808A - DETAILS
2015-05-12T14:07:07-0700
Jeff Kanyuch
2015-05-12T14:07:21-0700
Jeff Kanyuch
2015-05-12T14:07:21-0700
Jeff Kanyuch
2015-05-12T14:07:21-0700
Jeff Kanyuch
2015-05-12T14:07:22-0700
Jeff Kanyuch
2015-05-12T14:07:22-0700
Jeff Kanyuch
2015-05-12T14:07:22-0700
Jeff Kanyuch
2015-05-12T14:07:22-0700
Jeff Kanyuch

File details come from the government source that posted it. Updated .