About this file

This is Amendment 0002 dated February 19, 2025, for IFB N4008425B5403, which modifies multiple sections of the Performance Work Statement (PWS) for Indoor Small Arms Range (ISAR) Cleaning and Ventilation System Maintenance Services at MCAS Iwakuni, Japan.

Key changes include: modifications to the Table of Contents, addition of Environmental Manager (EM) requirements, removal of ventilation system paragraph (making contractor responsible for employee safety), revision of the cleaning schedule with training range cleanings increased from 6 to 10 times per year, and reduction of backroom cleanings from 6 to 2 times per year. Other minor changes include formatting corrections, acronym additions, and title corrections across various sections including Government Regular Working Hours, Quality Manager requirements, and Unit Priced Labor Work specifications. The amendment spans multiple pages of the PWS (from page 7 through 195) and includes updates to both Section C and Section J attachments.

View the file

Other files

File Type Posted
25B5403_A0007.pdf PDF
J-0200000-10 ELINs -ISAR_A0006.xlsx XLSX spreadsheet
Amendment list -ISAR_A0006.pdf PDF
A0006_Gvt_Responses.pdf PDF
25B5403_A0006.pdf PDF
25B5403_A0005.pdf PDF
25B5403_A0004.pdf PDF
A0003_Gvt_Responses.pdf PDF
25B5403_A0003.pdf PDF
Amendment list -ISAR_A0003.pdf PDF
25B5403_A0002.pdf PDF
GVTResp_PPI01.pdf PDF
25B5403_A0001.pdf PDF
Atch(3)_Escort Request Form_Entry-Exit.pdf PDF
SF1449_25B5403.pdf PDF
Atch (2) J-0200000-10 ELINs -ISAR.xlsx XLSX spreadsheet
Atch(4)_PreAward_Inquiry_Form.xlsx XLSX spreadsheet
Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IFB N4008425B5403, Amendment 0002 Enclosure (1)

19 Feb 2025

The changes listed below have been made to the applicable sections of the IFB attachment.

# Spec or

Attachment

No.

Annex Title Amendment SPEC

File

Page No.

1 Section C

(1) Multiple 0200000 Table of Contents Corrections made. PWS

A0002

Pages 7

& 8 of

(2) 2.2 0200000 Government Regular

Working Hours

Extra space deleted. PWS

A0002 of 195

(3) 2.7.1.2 0200000 Quality Manager (QM) Acronym added to the title. PWS

A0002 of 195

(4) 2.7.1.4 0200000 Environmental Manager

(EM)

EM requirements added. PWS

A0002

Pages 17

& 18 of

(5) 2.8.9 0200000 Access to Government

Information Technology

(IT), Operational Technology (OT), and

Facility Related Control

Systems (FRCS)

Title corrected PWS

A0002 of 195

(6) 2.15.2 0200000 Unit Priced Labor (UPL) Work (Negotiated)

A space added to the title. PWS A0002 of 195

(7) 2.3.3 1800000 Work Site Preparation Typo corrected. PWS A0002 of 195

(8) 3.1 1800000 Indoor Small Arms

Range (ISAR) Cleaning

- The paragraph regarding the cleaning schedule revised.

- Paragraph regarding the ventilation system removed. (It will be the Contractor’s responsibility to ensure the safety of its employees.)

PWS

A0002 of 195

2 Section J

(1) J-1800000-03 1800000 Cleaning Areas Notes revised. PWS

A0002

# Spec or Attachment

No.

Annex Title Amendment SPEC File

Page No.

(2) J-1800000-04 1800000 Cleaning Schedule Schedule revised.

- The number of training range cleanings increased to 10 times a year vice six times a year.

- The number of backroom cleanings reduced to twice a year vice six times a year.

Notes updated.

PWS

A0002