View the file

Other files

File Type Posted
20B5402_A0005.pdf PDF
Encl(1)_Government_Response_A0005.pdf PDF
20B5402_A0004.pdf PDF
Encl(2)_Amendment_List_A0004.pdf PDF
Encl(1)_PWS_Replacement_Pages_A0004.pdf PDF
Atch(2)_J-0200000-16_ELINs_A0004.xlsx XLSX spreadsheet
Encl(1)_Government_Response_A0003.pdf PDF
20B5402_A0003.pdf PDF
20B5402_A0002.pdf PDF
Encl(1)_Goverment_Response_A0002.pdf PDF
Encl(1)_Government_Response_A0001.pdf PDF
Encl(3)_Amendment_Llist_A0001.pdf PDF
Encl(2)_PWS_Replacement_Pages_A0001.pdf PDF
20B5402_A0001.pdf PDF
20B5402_SF1449.pdf PDF
Atch(2)_J-0200000-16_ELINs.xlsx XLSX spreadsheet
Atch(4)_PreBid_Inquiry_Form.xlsx XLSX spreadsheet
Atch(3)_1-Day_Official_Entry-Exit_Request.pdf PDF
Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Data-a3f3%.doc Sheet 1 of 2 10/6/00 rev 3/6/09

47 Sarahs Way Coatesville, PA 19320

Tel No 610-466-1717 Fax No 610-466-1718 Web Site www.vectorfire.net

PLANIT SAFE TM 3% Test Liquid

Data Sheet Description

PLANIT SAFE™ 3% Test Liquid is intended to be used as a substitute for 3% AFFF foam concentrate during proportioning system tests. It minimizes cost and environmental concerns associated with using AFFF fire fighting foams for system testing. Because it is supplied as a super concentrate PLANIT SAFE™ Test Liquid saves handling costs. Each drum of super concentrate can be diluted to make 3 drums of PLANIT SAFE™ 3% test liquid on site.

PLANIT SAFE™ 3% Test Liquid is specifically formulated to simulate the flow behavior

(viscosity characteristics) and approximate conductivity level of AFFF foam concentrates. System proportioning injection rate can be determined by measuring conductivity of the solution stream.

Since PLANIT SAFE™ Test Liquid contains no toxic ingredients, disposal of the proportioned stream into drains and sewers or waterways is not expected to cause an environmental impact.

When diluted by the proportioning process PLANIT SAFE™ 3% Test Liquid has been found to meet most local water quality standards. In most cases, the diluted PLANIT SAFE™ 3% Test

Liquid solution will not be subject to disposal by treatment facilities. However, it is always advisable to consult with State, Provincial or local authorities having jurisdiction regarding proper disposal procedures to be followed prior to discharge.

Features Environmentally responsible Compatible with existing proportioning equipment Non-toxic, non-corrosive, non foaming Saves costly containment and disposal associated with foam release Simulates physical behavior of foam concentrate Excellent biodegradability

Physical Properties

Appearance----------------------------------------------------------Clear Liquid Specific Gravity @ 77 deg F--------------------------------------1.005 –1.010 pH---------------------------------------------------------------------7.5 - 8.5 Minimum Usable Temp.-------------------------------------------35 deg F Maximum Usable Temp.------------------------------------------120 deg F Freezing Point-------------------------------------------------------32 deg F Viscosity-------------------------------------------------------------2.5-3.5 csks @ 68 deg F

Kaname Yoshimasu 四角形

Kaname Yoshimasu 四角形 youko.abe.ja Typewritten Text N4008420B5402, Amendment 0005 Enclosure (2)

Data-a3f3%.doc Sheet 2 of 2 10/6/00 rev 3/6/09

Coatesville, PA 19320

Tel No 610-466-1717 Fax No 610-466-1718 Web Site www.vectorfire.net

Compatibility

PLANIT SAFE™ 3% Test Liquid should never be mixed, stored, or used with any type of foam concentrate. All proportioning equipment should be thoroughly flushed after use with PLANIT SAFE™ Test Liquid.

Storage, Handling and Shelf Life

PLANIT SAFE™ Test Liquid should be stored in its original sealed shipping container. Test liquids are subject to evaporation that accelerates product deterioration when exposed to air. It is recommended that PLANIT SAFE™ Test Liquid be stored at temperatures between 35 deg F and

120 deg F. PLANIT SAFE™ Test Liquid should be used within 1 year from shipment assuming it is stored properly.

Environmental and Toxicological Information

PLANIT SAFE™ Test Liquid contains no ingredients that are reportable under the Superfund

Amendment and Reauthorization Act (SARA) Title III, Section 313 of 40 CFR-372 or the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA).

The biological oxygen demand (BOD) and chemical oxygen demand (COD) of PLANIT SAFE™ 3% Test Liquid and 3% proportioned (diluted) solution are as follows:

3% Test Liquid As Dilute 3% Solution Concentrate(mg/l) Proportioned Stream (mg/l)

BOD-5 658 18

COD 8,120 238 (rev 4/15/04)

NOTE: BOD measurement derived by EPA test method 405.1 and COD measurement derived by EPA test method 410.4.

The acute toxicity of Planit Safe 3% test liquid as a dilute solution has been studied and found to have a 96 hour LC50 value for Oncorhyncchus mykiss (rainbow trout) of less than 100mg/L. There was no fish mortality after the 96 hour test duration. An LC50 of less than 100mg/L is less than the regulatory threshold established for dangerous waste. (rev 3/6/09)

Results of tests for acute oral toxicity and primary skin irritation have not been conducted.

Repeated skin contact will remove oils and cause dryness. PLANIT SAFE™ Test Liquid is a primary eye irritant and therefore contact with eyes should be avoided. Users are advised to wear protective equipment. If the test liquid enters the eyes, flush them well with fresh clean water.

Consult a physician if irritation persists. Consult the PLANIT SAFE™ Test Liquid Material

Safety Data Sheet for further details.

MS A3F1% (HEC) 1

Coatesville, PA 19320 Phone: 610-466-1717 Fax: 610-466-1718 www.vectorfire.net

MATERIAL SAFETY DATA SHEET #MSA3F1% (HEC Formula)

PLANIT SAFE TM 1% (HEC) AFFF SUBSTITUTE TEST LIQUID

Also Used as Super Concentrate to Produce 3% & 6% Test Liquids

Section 1. CHEMICAL PRODUCT/ COMPANY IDENTIFICATION

Material Identification

Product: PLANIT SAFE 1% Test Liquid

Synonyms: Test Liquid CAS No.: Mixture – No single CAS No. applicable

Company Identification Manufacturer:

Vector Fire Technology, Inc.

47 Sarahs Way Coatesville, PA 19320

Phone: 610-466-1717 Fax: 610-466-1718

Section 2. COMPOSTION/ INFORMATION OF INGREDIENTS

Components CAS No.

Water 7732-18-5

Potassium Chloride 7447-40-7

Sodium Benzoate 532-32-1

Hydroxyethylcellulose 9004-62-0

MS A3F1% (HEC) 2

Section 3. HAZARDS IDENTIFICATION

Potential Health Effects

Inhalation Vapors are minimal at room temperature. If product is heated or sprayed as an aerosol, airborne material may cause respiratory irritation.

Skin Contact Contact with liquid may cause irritation or dermatitis due to removal of oils from the skin.

Eye Contact Contact with liquid may cause eye irritation.

Ingestion Not a hazard in normal industrial use. Small amounts swallowed during normal handling operations are not likely to cause injury; swallowing large amounts may cause injury or irritation.

Additional Health Effects Existing eye or skin sensitivity may be aggravated by exposure.

Carcinogenicity Information No data available.

Section 4. FIRST AID MEASURES

Inhalation No specific treatment is necessary since this material is not likely to be hazardous by inhalation.

If exposed to excessive levels of airborne aerosol mists, remove to fresh air. Seek medical attention if effects occur.

Skin Contact In case of skin contact, wash off with flowing water or shower. Launder clothing before re-use.

Eye Contact In case of eye contact, flush eyes promptly with water for 15 minutes. Retract eyelid often to ensure thorough rinsing. Contact physician if irritation persists.

Ingestion Swallowing less than an ounce is not expected to cause significant harm. For larger amounts do not induct vomiting. Give milk or water. Never administer anything by mouth to an unconscious person. Seek medical attention.

MS A3F1% (HEC) 3

Section 5. FIRE FIGHTING MEASURES

Flammable Properties Flash Point – Not Applicable

Fire and Explosion Hazards Avoid contact with water reactive materials, burning metals and electrically energized equipment.

Extinguishing Media Product is not an extinguishing media. Use media appropriate for surrounding materials.

Special Fire Fighting Instructions None

Section 6. ACCIDENTAL RELEASE MEASURES

Safeguards (Personnel) NOTE: Review FIRE FIGHTING MEASURES and HANDLING (Personnel) sections before proceeding with clean-up. Use appropriate Personal Protective Equipment during clean-up.

Accidental Release Measures

Super Concentrate or Test Liquid Solution Stop flow if possible. Dilute with water to meet existing water quality standards. Flush area with water. Exercise caution, surfaces may be slippery. Disposal should be made in accordance with federal, state and local regulations.

Section 7. HANDLING AND STORAGE

Handling (Personnel) Avoid contact with eyes, skin, or clothing. Avoid ingestion or inhalation. Rinse skin and eyes thoroughly in case of contact. Review HAZARDS and FIRST AID sections.

Storage Recommended storage environment is between 35ºF (2ºC) and 120ºF(49ºC). Store product in original shipping container or tanks designed for product storage.

MS A3F1% (HEC) 4

Section 8. EXPOSURE CONTROLS/PERSONAL PROTECTION

Engineering Controls Special ventilation is not required.

Personal Protective Equipment

Respiratory Recommended exposure limits (OSHA-PEL and ACGIH-TLV) have not been determined for this material. The need for respiratory protection should be evaluated by a qualified health specialist.

Protective Clothing Rubber or PVC gloves recommended.

Eye Protection Safety glasses, face shield, or chemical splash goggles must be worn when possibility exists for eye contact. Contact lenses should not be worn. Eye wash facilities are recommended.

Other Hygienic Practices Use good personal hygiene practices. Wash hands before eating, drinking, smoking, or using toilet facilities. Promptly remove soiled clothing and wash thoroughly before re-use.

Exposure Guidelines Not Available

MS A3F1% (HEC) 5

Section 9. PHYSICAL AND CHEMICAL PROPERTIES

Physical Data

Boiling Point: Not applicable

Vapor Pressure: Not applicable

Vapor Density: Not applicable

Melting Point: Not applicable

Evaporation Rate: <1 (Butyl Acetate= 1.0)

Solubility in Water: 100% pH: 6.8 - 8.0

Specific Gravity: 1.024 @ 20ºC

Odor: Bland

Form: Liquid

Color: Clear

Section 10. STABILITY AND REACTIVITY

Chemical Stability Stable

Incompatibility, Materials to Avoid Avoid use of product on burning metals, electrically-energized equipment and contact with water reactive materials.

Polymerization Will not occur.

MS A3F1% (HEC) 6

Section 11. TOXICOLOGICAL INFORMATION

Mammalian Toxicity

This product has not been tested as a whole for acute oral and inhalation toxicity, primary eye irritation, or primary skin irritation.

Section 12. ECOLOGICAL INFORMATION

Ecotoxicological Information Aquatic Toxicity (rev C 3/6/09) The acute toxicity of Planit Safe 3% test liquid as a dilute solution has been studied and found to have a 96 hour LC50 value for Oncorhyncchus mykiss (rainbow trout) of less than 100mg/L.

There was no fish mortality after the 96 hour test duration. An LC50 of less than 100mg/L is less than the regulatory threshold established for dangerous waste.

Environmental Fate

1% Concentrate 3% Concentrate As Proportioned As Shipped Dilution of 1% Stream with Water (mg/l) (mg/l) (mg/l)

BOD-5 Day 2,154 658 18

COD 24,360 8,120 238 (rev A 4/15/04)

Section 13. DISPOSAL CONSIDERATIONS

PLANIT SAFE AFFF Test Liquid Concentrate, as sold, is not a RCRA- listed waste or hazardous waste as characterized by 40 CFR 261. However, State, and local requirements for waste disposal may be more restrictive or otherwise different from Federal regulations. Proper clean up and disposal of this material into drains, sewers, or waterways is not expected to cause an environmental impact, however, consult with state or local authorities having jurisdiction regarding the proper regulations, requirements, or concerns encompassed within your site disposal plan.

PLANIT SAFE AFFF Test Liquid Concentrate can be treated by waste water treatment facilities. Discharge into biological sewer treatment facilities may be done with prior approval.

Specific concerns are high BOD load. Dilution will reduce BOC and COD factors proportionately. Low dosage flow rate to the treatment plant may be helpful. Disposal should be made in accordance with federal, state and local regulations.

MS A3F1% (HEC) 7

Section 14. TRANSPORTATION INFORMATION

Shipping Information Proper Shipping Name: Not a DOT Hazardous Substance Hazard Class: Not Regulated UN Number: None

Section 15. REGULATORY INFORMATION

U.S. Federal Regulations

Toxic Substances Control Act (TSCA) All components of this product are listed in the TSCA inventory.

Superfund Amendments and Reauthorization Act of 1986 (SARA), Title III

Section 302/304 There are no components of this material with known CAS numbers which are on the Extremely Hazardous Substances (EHS) list.

Section 311 & 312 This material does not contain any components subject to Section 311 & 312 reporting requirements.

Section 313 This material does not contain any components subject to Section 313 reporting requirements.

COMPREHENSIVE ENVIRONMENTAL RESPONSE, COMPENSATION, AND

LIABILITY ACT (CERCLA)

This material does not contain any components which are subject to the reporting requirements of CERCLA.

OTHER REGULATORY INFORMATION

None

STATE REGULATIONS

PENNSYLVANIA RIGHT-TO-KNOW HAZARDOUS SUBSTANCES LIST

PA Hazardous Substances present at levels greater than 1%:

None

MS A3F1% (HEC) 8

Section 16. OTHER INFORMATION

NFPA Rating Health 0 Flammability O Reactivity O

ADDITIONAL INFORMATION

Revision Summary 1/29/03 New Issue 4/15/04 Rev A 6/10/04 Rev B 3/6/09 Rev C

The information contained herein is furnished without warranty either expressed or implied. This data sheet is not a part of any contract of sale. The information contained herein is believed to be correct or is obtained from sources believed to be generally reliable. However, it is the responsibility of the user of these materials to investigate, understand, and comply with federal, state and local guidelines and procedures for safe handling and use of these materials. Vector Fire Technology, Inc. shall not be liable for any loss or damage arising directly or indirectly from the use of this product and Vector Fire Technology, Inc. assumes no obligation or liabilities for reliance on the information contained herein or omissions herefrom.

AFFF Test Liquid Concentrate

** NOT FOR USE ON FIRE**

Environmentally Safe Concentrate for testing foam proportioning equipment

Recommended Storage Temperatures: Minimum 35˚F (2˚C) to Maximum 120˚F (49˚C)

Instructions

Use to test proportioning equipment in place of foam concentrate. Not for any other purpose.

Store within temperatures shown above.

To prepare a 3% test liquid, dilute or proportion water with 2 parts water to one part Super Concentrate.

Resulting liquid can be diluted or proportioned with water at 3% (3 parts diluted Super Concentrate/ 97 parts water).

Do not mix with any foam concentrate or otherwise contaminate.

When not in use, keep container tightly closed at all times and away from heat, flame or cold temperatures.

Do not reuse container. After use dispose of empty container in accordance with applicable federal, state and local regulations.

ENVIRONMENTAL NOTICE: This product does not contain reportable components under SARA Title III

Caution:

Do not take internally.

Protect skin and eyes before using.

Genetic chemical identities are provided for substances considered to be a proprietary trade secret. This product has not been tested as a whole for acute oral toxicity, primary eye irritant or primary skin irritant and may or may not be considered toxic.

Safety Instructions

In case of accidental contact with eyes, flush with water and consult physician immediately.

If accidentally spilled, this product may present a slip hazard. Clean up spills promptly by flushing with water.

Foodstuffs or animal feeds which have come in contact with this product should be discarded.

Notice to Customer/User This product is NOT to be used in the suppression or control of fire. Vector Fire Technology, Inc. does not warrant the use of this product. Customer/ User should be aware that dilution, contamination with other substances or storage outside of the recommended temperature ranges shown on this label may render this product ineffective for it’s intended use.

Before using, Customer/ User shall determine the suitability of this product for it’s intended use and user assumes all risk and liability whatsoever in connection therewith. Neither seller nor Vector Fire Technology, Inc. shall be liable in tort or in contract for any loss or damage, direct, incidental or consequential, arising out of the use of or inability to use this product.

Contents:

Water, Viscosity Modifiers, Inorganic Salt

Contains 55 US Gallons (208.2 liters) 536 lb (243 kg.)

Vector Fire Technology, Inc. 47 Sarahs Way Coatesville, PA 19320 Phone (610) 466-1717

Kaname 長方形