Amend 2 - Attachment nr. 1 asbestos.pdf

PDF 514 KB Posted

Attached to
Grindavik Eruption Repairs, Grindavik NRTF, Iceland
Solicitation number
N33191-25-R-0010
Issued by

About this file

This document is an asbestos sampling and analysis report for Fjarskiptastöð Grindavík, conducted on 24.08.2016 by Skima ehf. The report details the results of bulk material sampling across multiple locations, specifically Building 2606 and 2621 (Drama), using Polarized Light Microscopy (PLM) analysis per OSHA Analytical Method. Key findings include the presence of chrysotile asbestos (>1%) in three samples: grey floor tile (Sample 6), red floor tile (Sample 7), and mastic for grey and red tiles (Sample 8), all located in room 2621. The report notes that these asbestos-containing materials have well-bonded or embedded fibers that are unlikely to come loose easily. Additional areas surveyed (Power house, Sewer pump house, Old water house) showed no suspected asbestos-containing materials, and no samples were taken from those locations. The accompanying floor plan provides a detailed layout of sampling locations within the buildings.

View the file

Other files

File Type Posted
Amend 2 - Goverment Response to PPI.pdf PDF
Amendment 0002.pdf PDF
Amend 2 - Attachment nr. 2 - road blue line.png PNG image
Amendment 01.pdf PDF
Solicitation N3319125F0010.pdf PDF
Attachment 2 PPI Form.xlsx XLSX spreadsheet
Attachment 4 Price Schedule.docx DOCX document
Attachment 1 Specification.pdf PDF
Attachment 3 PPQ.doc DOC document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Location: Fjarskiptastöð Grindavík Date: 24.08.2016

Type of sampling and analysis: Bulk samples – Building materials

Sample number

Material type and location

Asbestos Type Other fibrous materials

Comments

Office wall board “COR” Office 2606

No Gypsum, wood and glass fibers

2 Office ceiling tiles “COR” Office 2606

No Gypsum, wood fibers

3 Wall tiles insulation east end 2606

No Wood fibers, glue

4 Wall board w/white paint west end 2606

No Masonite, wood fibers

5 Ceiling insulation north west corner 2606

No Glass fibers

6 Floor tile grey from inner floor 2621 (Drama)

Yes Chrysotile >1%

Fibers are well bonded and will not easily come loose

7 Floor tile red from inner floor 2621 (Drama)

Yes Chrysotile >1%

Fibers are well bonded and will not easily come loose

8 Mastic for grey and red tiles in 2621 (Drama)

Yes Chrysotile >1%

Fibers are embedded in mastic and will not easily come loose

9 Mastic for brown vinyl flooring 2621 (Drama)

No No fibers detected

10 Wall board insulation inside entrance 2621 (Drama)

No Wood and glass fibers, glue

11 Floor tile grey on platform south of 2621

12 Brown mastic for grey floor tiles on platform south of 2621

The below areas were surveyed for building materials that where known or suspected to contain asbestos materials.

2608 Power house No suspected materials found – No samples taken

2612 Sewer pump house No suspected materials found – No samples taken

2614 Old water house No suspected materials found – No samples taken

Skima ehf Asbestos sampling and analysis Þórður Karlsson

Tel: 861-3266

Email: skima@simnet.is

Analytical method: Polarized Light Microscopy; PLM Method reference: OSHA Analytical

Method (OSHA ID191)

Bldg. 2621 (Drama)

Entrance

Platform outside

Sample# 1 Sample# 2

Sample# 3

Sample# 4

Sample# 5

Sample # 9

Samples # 6, 7, 8

Sample # 10

Sample # 11, 12

Samples

1. Office wall

2. Office ceiling tile

3. Wall panel insulation brown

4. Wall board with white paint

5. Ceiling insulation

6. Floor tile grey

7. Floor tile Red

8. Mastic for 6&7

9. Mastic for brown vinyl flooring

10. Wall board insulation

11. Floor tile grey outside

12. Brown mastic for 11

Fjarskiptastod Grindavik Asbestos Sampling
Sample locations Grindavik