Amend 2 - Attachment nr. 1 asbestos.pdf
PDF 514 KB Posted
- Solicitation number
- N33191-25-R-0010
About this file
This document is an asbestos sampling and analysis report for Fjarskiptastöð Grindavík, conducted on 24.08.2016 by Skima ehf. The report details the results of bulk material sampling across multiple locations, specifically Building 2606 and 2621 (Drama), using Polarized Light Microscopy (PLM) analysis per OSHA Analytical Method. Key findings include the presence of chrysotile asbestos (>1%) in three samples: grey floor tile (Sample 6), red floor tile (Sample 7), and mastic for grey and red tiles (Sample 8), all located in room 2621. The report notes that these asbestos-containing materials have well-bonded or embedded fibers that are unlikely to come loose easily. Additional areas surveyed (Power house, Sewer pump house, Old water house) showed no suspected asbestos-containing materials, and no samples were taken from those locations. The accompanying floor plan provides a detailed layout of sampling locations within the buildings.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 2 - Goverment Response to PPI.pdf | ||
| Amendment 0002.pdf | ||
| Amend 2 - Attachment nr. 2 - road blue line.png | PNG image | |
| Amendment 01.pdf | ||
| Solicitation N3319125F0010.pdf | ||
| Attachment 2 PPI Form.xlsx | XLSX spreadsheet | |
| Attachment 4 Price Schedule.docx | DOCX document | |
| Attachment 1 Specification.pdf | ||
| Attachment 3 PPQ.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Location: Fjarskiptastöð Grindavík Date: 24.08.2016
Type of sampling and analysis: Bulk samples – Building materials
Sample number
Material type and location
Asbestos Type Other fibrous materials
Comments
Office wall board “COR” Office 2606
No Gypsum, wood and glass fibers
2 Office ceiling tiles “COR” Office 2606
No Gypsum, wood fibers
3 Wall tiles insulation east end 2606
No Wood fibers, glue
4 Wall board w/white paint west end 2606
No Masonite, wood fibers
5 Ceiling insulation north west corner 2606
No Glass fibers
6 Floor tile grey from inner floor 2621 (Drama)
Yes Chrysotile >1%
Fibers are well bonded and will not easily come loose
7 Floor tile red from inner floor 2621 (Drama)
Yes Chrysotile >1%
Fibers are well bonded and will not easily come loose
8 Mastic for grey and red tiles in 2621 (Drama)
Yes Chrysotile >1%
Fibers are embedded in mastic and will not easily come loose
9 Mastic for brown vinyl flooring 2621 (Drama)
No No fibers detected
10 Wall board insulation inside entrance 2621 (Drama)
No Wood and glass fibers, glue
11 Floor tile grey on platform south of 2621
12 Brown mastic for grey floor tiles on platform south of 2621
The below areas were surveyed for building materials that where known or suspected to contain asbestos materials.
2608 Power house No suspected materials found – No samples taken
2612 Sewer pump house No suspected materials found – No samples taken
2614 Old water house No suspected materials found – No samples taken
Skima ehf Asbestos sampling and analysis Þórður Karlsson
Tel: 861-3266
Email: skima@simnet.is
Analytical method: Polarized Light Microscopy; PLM Method reference: OSHA Analytical
Method (OSHA ID191)
Bldg. 2621 (Drama)
Entrance
Platform outside
Sample# 1 Sample# 2
Sample# 3
Sample# 4
Sample# 5
Sample # 9
Samples # 6, 7, 8
Sample # 10
Sample # 11, 12
Samples
1. Office wall
2. Office ceiling tile
3. Wall panel insulation brown
4. Wall board with white paint
5. Ceiling insulation
6. Floor tile grey
7. Floor tile Red
8. Mastic for 6&7
9. Mastic for brown vinyl flooring
10. Wall board insulation
11. Floor tile grey outside
12. Brown mastic for 11
| Fjarskiptastod Grindavik Asbestos Sampling |
| Sample locations Grindavik |
File details come from the government source that posted it. Updated .