Text version
N32205-17-R-4011
USNS YUKON (T-AO 202)
REQUEST FOR SPECIFICATION CLARIFICATION
SPECIFICATION ITEM NO.: 103
PARAGRAPH / SECTION NO: 7.2.2
TITLE: CHAIN LOCKER SUMP PRESERVATION AND STEEL REPAIRS
QUESTION:
Paragraph requires contractor to renew 25sq feet of bhd 18.
Question: Could you please provide plate dimensions and possibly a sketch showing the intended area to be renewed in relation to the chain locker boundary. This will be needed to determine access requirements to rig the material in and quantity/location of scaffolding.
ANSWER:
The area being renewed is an estimate and may decrease or increase depending on what is determined by ABS after sump is blasted. The dwgs provided are all we have showing the location of the sump. The contractor will have to do a ship check to determine best access for material.
ATTACHMENT J - 8