Installation Drawings
Customer: GEA WS INC, USA
Hull/ Projekt: MV Ryndam / MV Statendam
MV Veendam / MV Maasdam
WS- Ordernumber: 1.451.179.161 / 1.451.180.437
1.451.180.440 / 1.451.180.443 engineering for a better world
1. Installation Instructions, Graphical Symbols
2. HFO
Contents
GEA Mechanical Equipment / GEA Westfalia Separator Group
Installation Instructions
For Separators
No. 2058-9601-020
Edition 0211
2 2058-9601-020 / 0211
Westfalia Separator®
ORIGINAL INSTRUCTION MANUAL
Subject to modification!
The authors are always grateful for comments and suggestions for improving the documentation. They can be addressed to:
GEA Mechanical Equipment
GEA Westfalia Separator Group GmbH
Werner-Habig-Str. 1, 59302 Oelde (Germany) Phone +49 2522 77-0, Fax +49 2522 77-2488 ws.info@geagroup.com, www.westfalia-separator.com
2058-9601-020 / 0211 3
Preface
These installation guidelines
• are part of the overall documentation compiled for the separator.
• describe the procedures for constructing, manufacturing and design-ing separators.
• contain fundamental instructions for installing separator installations.
• contain general guidelines for separator installations.
These guidelines specify the minimum specifications for designing and constructing frames, tanks, piping and the electrical installation.
Putting together and installing the installation components must be carried out in accordance with the order-specific documents:
• Installation diagram and equipment list
• Dimensioned drawing (notes on required space for operating and servicing, minimum clearance from walls/pillars or other machines)
We reserve the right to carry out technical modifications on the separator!
Attention must be paid to the operating, maintenance and mounting instruction manuals of all units and fittings.
For your safety
• Take special care when carrying out operations marked with this symbol -otherwise danger to life!
• Strictly adhere to instructions marked with this symbol.
This avoids damage to the separator and other equipment.
Note: • This symbol is not a safety precaution but rather a reference to infor-mation which help to better understand the separator or plant compo-nents and the processes.
• Use only genuine spare parts from GEA Westfalia Separator. The origi-nal spare parts are listed in the spare parts catalog.
The use of non-genuine parts leads to:
– safety risks,
– reduced durability of these parts,
– reduced availability of the separator and
– increased service requirement.
If a safety risk occurs when using non-original spare parts, this may have legal consequences for the responsible persons. In such cases, GEA Westfalia Separator accepts no liability or warranty claims.
4 2058-9601-020 / 0211
1 General 7
1.1 Safety precautions
1.2 Material
1.3 Installation
1.4 Storage
1.4.1 Installation of controls
1.5 Transport
1.5.1 Transporting the separator
1.6 Preservation measures on site
2 Separator 19
2.1 Space requirement for separators
2.1.1 Separators with belt drive
2.2 Bowl weights
2.3 Required hoist specifications for separators
2.4 Ventilating the separator room
2.5 Foundations
2.6 Securing the separators
2.6.1 Separators OSD 6, 18, 35, 60, OSE 5, 10, 20, 40, 80 and
OTC 5, 10, 20
2.7 Welding procedure for fastening the foundation frame
2.7.1 Installing the separator
2.8 Vibrations
2.9 Pipelines on the separator
2.9.1 Product line
2.9.2 Operating, filling and displacement water lines
3 Operating, filling and displacement water 33
3.1 Water quality
3.2 Supply pressure and temperature
3.3 Water connection for operating, filling and displacement water
3.4 Dimensions and number of consumers
3.5 Water quantity
4 Compressed air 37
4.1 Compressed air quality
4.2 Supply pressure
4.3 Compressed air consumption of the separators OSD, OSE and OTC.. 38
5 Product lines 39
5.1 General
5.2 Pipe cross-sections
5.3 Functional description
2058-9601-020 / 0211 5
5.4 Information on pressure monitoring
5.5 Piping
5.6 Maximum suction head
5.6.1 Pressure line
5.6.2 Pre-filter
5.7 Feed pump
5.8 Oil pre-heater
5.9 Installation examples
5.9.1 Steam-heated plate heat exchanger with (PI controlled) control valve . 45
5.9.2 Steam-heated tubular heat exchanger with (PI controlled) control valve
5.9.3 Thermal oil-heated plate heat exchanger with (PI controlled) control valve
5.9.4 Thermal-oil-heated tubular heat exchanger with (PI controlled) control valve
5.10 Securing plate heat exchangers
5.11 Safety valve
6 Solids tank 51
6.1 Recommended criteria for solids tank
6.1.1 Tank vent
6.1.2 Set-up of the solids tank venting
6.2 Solids discharge lines
6.2.1 Solids discharge lines with shut-off flap
6.2.2 Standard installation of shut-off flaps
6.2.3 Installation recommendation for shut-off flaps
6.3 Operating and dirty water discharge lines
6.3.1 Separators of OSD and OSE
7 Electrical installation 61
7.1 Control cabinet
7.1.1 Electrical connection
7.1.2 External voltages
7.1.3 Shipboard operation
7.1.4 Onshore operation
7.2 Electro-magnetically compatible installation
7.3 Valves
7.3.1 Solenoid valve block
7.3.2 Terminal box
7.3.3 Separator with sensor bloc
7.4 Dual-purpose thermometer
7.5 Electrical installation of transmitters and electric motors
7.6 Electrical execution
7.6.1 Earthing the separator
7.6.2 Voltage equalisation of the separator
7.6.3 Voltage equalization of the electric heater
7.6.4 Voltage equalization of the foundation frame
7.6.5 Voltage equalisation of the control cabinet
7.7 Electric motors procured by the customer
7.8 Installation and operation of control units
6 2058-9601-020 / 0211
NNoottee NNootteess
NNoottiizzeenn AAnnoottaacciioonneess ДДлляя ззааппииссеейй MMuuiissttiiiinnppaannoott ΣΣηημμεειιώώσσεειιςς
NNoottaatteerr
2058-9601-020 / 0211 7
1 General
1.1 Safety precautions
1.2 Material
1.3 Installation
1.4 Storage
1.4.1 Installation of controls
1.5 Transport
1.5.1 Transporting the separator
1.6 Preservation measures on site
8 2058-9601-020 / 0211
1.1 Safety precautions
• Pay special attention to the safety precautions contained in the overall documentation compiled for the separator!
1.2 Material
• The specified material must conform to the standards set out in these installa-tion guidelines as a minimum requirement.
• All materials used must be new and from the same series.
1.3 Installation
Fig. 1 Installation example
1 Separator: 7 Solids tank venting 2 Separator foundation 8 Crane 3 Control unit 9 Cleaning table 4 Control cabinet 10 Aeration 5 Preheater 11 Venting 6 Solids tank
• The applicable regulations and standards of classification societies or other authorised bodies must be observed.
• All lubricating points and the gear / drive housing of the separator must be easily accessible without having to remove pipes or gratings.
• All operating elements must be within comfortable reach of the operator and at a suitable height.
• Operating elements must not be mounted higher than 1800 mm above the working platform.
• All units must be arranged so that they do not cramp the working area and so that they can be safely serviced and operated.
2058-9601-020 / 0211 9
• All fixed piping and fittings must be safely supported to reduce vibrations and movement to a minimum.
• Contact points or supports must be fitted so that the pipes are able to move with changing temperatures without creating tension in the pipes.
• Pipes and pipe connections must be accessible for maintenance.
• Pipes must not be used for supporting distributors or appliances.
• These regulations and standards do not apply to small purpose-built parts whose durability, accessibility and operation are not influenced. They must be fitted in accordance with the manufacturer's recommendations.
• No galvanized parts may be fitted in product-carrying lines (e.g. heavy oil, diesel oil, steam lines and thermal oil lines). This does not apply if type-tested pipe joints are fitted in pipe trace heating systems.
• Y-strainers should preferably be fitted horizontally with the strainer insert pointing downwards or to the side (turned through 90°).
If this is not possible for space reasons, the dirt pan can be fitted vertically with a throughflow from top to bottom. In this case, ensure that the strainer can be dismantled.
10 2058-9601-020 / 0211
1.4 Storage
• Parts may be stored only in original GEA Westfalia Separator transport pack-aging.
• A storage time of more than 12 months is only possible after consulting the manufacturer.
• The storage site should be a closed, dry room.
• The storage temperature must not be below 5°C (41 F) and must not exceed 50 °C (122 °F).
IMPORTANT:
• Outdoor exposure is not admissible!
Pay attention to the following points on storage and transport packaging.
• Handle fragile goods with care!
• Protect the goods against moisture and humidity.
• Protect the goods against heat!
• Pay attention when erecting the goods.
1.4.1 Installation of controls
• Select the installation site so that
– the control unit is not exposed to dust and aggressive atmosphere.
– the control unit is not installed in an excessively humid environment or damp area.
– the sun cannot shine on the control panel or displays making operation and observation more difficult.
– heating up of the control unit is avoided.
• Where appropriate, check screw-type and plug-type connectors for secure contact.
2058-9601-020 / 0211 11
• Connect thermostatically controlled cabinet heating to external voltage and switch it on.
• The control cabinet heating must switch on before the temperature drops be-low the dew point.
• Bedewing can occur during the night which is not good for electronic appara-tus.
• Check that the line voltage and frequency conform to the connection data of the control unit (see nameplate).
• Pay attention to admissible installation and operating data:
Voltage fluctuations +/- 10 % of the line voltage Frequency fluctuations +/- 2 % of the line voltage Ambient temperatures + 5 to + 45 °C (41 to 113 °F) Atmospheric humidity max. 50 % at 40 °C (104 °F) max. 90 % at 20 °C (68 °F) Installation height above sea level up to 1000 m Transport temperatures – 25 to + 55 °C (–13 to 131 °F)
Improper installation and operation discharges the supplier from the warranty obligation.
12 2058-9601-020 / 0211
1.5 Transport
The adjacent packing illustrates a seaworthy packaging from GEA West-falia Separator.
Fig. 2
• After removing the side boards and filling material, the bottom board can be used as a special pallet for fork lift trucks.
Fig. 3
• If no forklift trucks are available, transport the case with the aid of a crane (see diagram).
• Attach the ropes to the points on the packing case as marked on the packing case.
Fig. 4
2058-9601-020 / 0211 13
• Attach ropes round the case and hang them into the load hook of the crane.
• CAUTION!
Wind one piece of rope twice round the hook to prevent the ropes from slipping.
Fig. 5
14 2058-9601-020 / 0211
1.5.1 Transporting the separator
• IMPORTANT:
To avoid damage, the bowl must be removed from the separator before transport.
• The separator is normally delivered without installed bowl.
Exception:
• The OTC 2, OTC 3, OSD 2 and
OSE 5 separators are delivered and transported with installed bowl.
Fig. 6
CAUTION!
Prevent accidents by using suitably rated hoists for transport and installa-tion.
• When transporting rope, make sure that one piece of rope is wound twice round the hook to prevent the
• The rope must be properly attached to the separator.
• Ensure that no pulling or pushing forces act on machine parts when using ropes.
Fig. 7
The following examples show how the transport ropes must be attached on the different frame designs (see Fig. 8 – Fig. 13).
2058-9601-020 / 0211 15
For OSD 6 or 18 and OSE 5, 10 and 20 – separator with belt drive
• Screw double nipple 1 into the hole in the frame.
Fig. 8
• Attach the transport ropes
– to the machine as illustrated and
– hang them into the load hook of the hoist as illustrated.
Wind one piece of rope twice round the hook to prevent the
• Make sure that the ropes do not damage any machine components.
• Do not use the eye bolt of the motor to suspend the separator.
• Make sure the machine touches down gently.
Fig. 9
16 2058-9601-020 / 0211
For OSD 35 and OSE 40 – separator with belt drive
• Screw two eye bolts 1 into the upper section of the frame.
• Screw double nipple 2 into the hole in the frame.
Fig. 10
– around the double nipple.
– Thread through the eye bolts and
– hang them into the load hook of the hoist as illustrated.
Wind one piece of rope twice
Fig. 11
2058-9601-020 / 0211 17
For OSD 60, OSE 80 and 120 – separator with belt drive
• Check that
– two eye bolts 1 are screwed into the upper section of the frame.
– Screw two eye bolts 2 with wash-ers 3 into the intermediate flange / frame holes.
Fig. 12
– Thread through the four eye bolts and
– hang them into the load hook of the hoist as illustrated.
Wind one piece of rope twice
Fig. 13
18 2058-9601-020 / 0211
1.6 Preservation measures on site
After installation until commissioning
• All parts such as tools, spare parts and bowl must be stored in the original packaging in a suitable place until commissioning.
• The parts must be stored at 5 to 50 °C (41 - 122 °F) in dry, weatherproof rooms to prevent the packaging from getting damaged.
• The spindle and gear/drive chamber are lubricated at the factory which pro-tects them for a period of 12 months.
• In the case of a storage and standstill period of longer than 12 months, the time-dependent maintenance intervals specified in the instruction manual must be adhered to before putting the machine back into operation.
• After this time (12 months) has expired, it must be checked at 12 monthly in-tervals that all bearings and the spindle have sufficient lubrication.
• Oil to be used:
– Shell oil S.7294 (SAE 30/SAE 50) for bearings and spindle,
– roller bearing grease for the spindle cap.
2058-9601-020 / 0211 19
2 Separator
2.1 Space requirement for separators
2.1.1 Separators with belt drive
2.2 Bowl weights
2.3 Required hoist specifications for separators
2.4 Ventilating the separator room
2.5 Foundations
2.6 Securing the separators
2.6.1 Separators OSD 6, 18, 35, 60, OSE 5, 10, 20, 40, 80 and
OTC 5, 10, 20
2.7 Welding procedure for fastening the foundation frame
2.7.1 Installing the separator
2.8 Vibrations
2.9 Pipelines on the separator
2.9.1 Product line
2.9.2 Operating, filling and displacement water lines
20 2058-9601-020 / 0211
2.1 Space requirement for separators
• No piping may be laid in the operating area apart from the feed and discharge lines for the separator.
2.1.1 Separators with belt drive
• The hatched area represents the operating area.
• See the following table to determine the operating area.
• Before installing the separator, pay special attention to the removal dimension X for the electric motors!
Front view of separator
Fig. 14
Side view of separator
Fig. 15
Top view of separator
Fig. 16
2058-9601-020 / 0211 21
Table for determining the operating area for separators with belt drive
Separator model
Dimensions in mm A B D E F G X Y
OTC 2 800 300 800 120 - 280 100 150
OTC 3 800 300 800 120 - 280 100 150
OTC 5 1400 600 1200 400 1250 375 540 150
OTC 10 1400 600 1400 550 1450 540 540 150
OTC 20 1400 600 1400 550 1550 630 630 150
OSD 2 800 300 800 200 - 280 100 150
OSD 6 1400 600 1400 550 1450 540 180 150
OSD 18 1400 600 1400 550 1550 630 180 150
OSD 35 1800 700 1800 650 1950 850 230 200
OSD 60 2000 800 2000 700 2500 1000 300 200
OSE 5 1400 600 1200 400 1250 375 540 150
OSE 10 1400 600 1400 550 1500 540 180 150
OSE 20 1400 600 1400 550 1650 630 180 150
OSE 40 1800 700 1800 650 2080 850 230 200
OSE 80 2000 800 2000 700 2250 1000 300 200
22 2058-9601-020 / 0211
2.2 Bowl weights
Fig. 17
Table with data for rating the lifting device
Separator model b h Bowl weight [kg]
OSD 6 255 270 42
OSD 18 300 320 72
OSD 35 425 420 190
OSD 60 536 530 360
OTC 5 220 225 25
OTC 10 260 265 40
OTC 20 315 310 52
Separator model b h Bowl weight [kg]
OSE 5 220 225 30
OSE 10 260 265 45
OSE 20 315 310 65
OSE 40 440 450 205
OSE 80 560 570 400
2058-9601-020 / 0211 23
2.3 Required hoist specifications for separators
Flat belt separators
• The hoist must be travel-type or swivel-type.
• The hoist must be arranged so as to enable the following:
– Vertical fitting and removal of the bowl (see section 2.1.1, table - dimension
F).
– Horizontal removal and fitting of the drive motor (see section 2.1.1, table -dimension X).
2.4 Ventilating the separator room
• Pay attention to the correct arrangement of the air feed and discharge lines so that
– the separator room is efficiently ventilated,
– the admissible room temperature – normally max. 45 °C (113 °F) – is not exceeded.
The rating of the electrical apparatus is critical in this respect.
If the admissible temperatures are exceeded, additional measures must be taken. Maintenance intervals and maintenance measures may have to be ad-justed accordingly.
Installation example of a ventilation system
Aeration Venting
Fig. 18
Approximate values for air exchange
For small closed separator rooms 30 - 50 h-1 For large separator rooms 15 - 20 h-1 For niches in engine rooms 50 - 70 h-1
24 2058-9601-020 / 0211
Table for air volumes pressed out of the housing
Air volume [m³/h]
OTC 2 10
OTC 3 10
OTC 5 10
OTC 10 10
OTC 20 10
OSD 2 10
OSD 6 10
OSD 18 30
OSD 35 100
OSD 60 150
OSE 5 10
OSE 10 10
OSE 20 30
OSE 40 100
OSE 80 150
2058-9601-020 / 0211 25
2.5 Foundations
In order to avoid the influence of external vibrations,
• Foundations and foundation frames for separators must not be rigidly con-nected to other foundations.
• If the foundation does not have adequate rigidity and flexural strength, this may result in loss of warranty.
Installation example for a founda-tion frame
1 Foundation
Fig. 19
• The foundation frames must be de-signed so that dimensions a and b in the table below are adhered to.
• When using other sections, the sec-tion modulus of the U-sections must not be lower than the value specified in DIN 1026.
• The foundation must be rigid with a maximum admissible deflection of 1:250.
• The separator feet must be fastened on the neutral axis of the frame.
Fig. 20
26 2058-9601-020 / 0211
Table for dimensioning foundation frames
Dimensions in mm a b
OTC 2 80 60
OTC 3 80 60
OTC 5 80 60
OTC 10 80 60
OTC 20 80 60
OSD 2 80 60
OSD 6 140 60
OSD 18 140 60
OSD 35 180 70
OSD 60 180 70
OSE 5 140 60
OSE 10 140 60
OSE 20 140 60
OSE 40 180 70
OSE 80 180 70
2058-9601-020 / 0211 27
2.6 Securing the separators
The following sections show how to secure the different separators:
Separators OTC 2, OTC 3, OSD 2
Assembly of separators with the aid of rubber-metal cushions on a steel foun-dation frame.
Fig. 21
• Screw rubber-metal cushions 4 into foundation 5.
• Screw studs 2 into rubber-metal cushions 4.
• Place plate 3 over the studs.
• Place the separator on plate 3 and
• bolt tight with hexagon nuts 1.
Fig. 22
ATTENTION!
The tightening torque for the stud screw 2 (M10) must be 30 Nm.
28 2058-9601-020 / 0211
2.6.1 Separators OSD 6, 18, 35, 60, OSE 5, 10, 20, 40, 80 and OTC 5, 10, 20
• Align separator 1 with feet 2 and plates 3 on foundation 4.
• Tack plates 3.
• Unscrew screws 5.
• Lift separator with feet (see section 1.5.1).
• Weld plates 3 to foundation 4.
• Place the separator on plates 3 and
• bolt tight with hexagon nuts 5.
• Screw tight hex head screws 6.
Fig. 23
The torques for the hex head screw 6 are specified in the table below.
Separator model Hex head screw Torque
OSD 6
M 12 52 Nm
OSD 18
OSD 35
M 16 100 Nm
OSD 60
OSE 5
M 12 52 Nm OSE 10
OSE 20
OSE 40
M 16 100 Nm
OSE 80
OTC 5
M 12 52 Nm OTC 10
OTC 20
2058-9601-020 / 0211 29
2.7 Welding procedure for fastening the foundation frame
The following sections show the welding procedure for fastening the foundation frame:
Mounting the separator installations on board of a ship
• The foundation frame 2 can be di-rectly welded onto the steel structure 2 from the shipyard.
Fig. 24
Example 1
• The length of the weld seams must be 100 mm.
• The distance between the weld seams must be approx. 350 mm.
This means that that there are 3 weld seams with a length of 100 mm along a length of one metre.
Example 2
• The foundation frame can likewise be welded all the way round. Fig. 25
Detail view
In this view you can see an example for welding the foundation frame to the steel structure.
The letter X indicates a fillet weld.
Fig. 26
30 2058-9601-020 / 0211
2.7.1 Installing the separator
Mounting the separator installations on board of a ship
• The frames must be fitted beneath the separator feet.
• The dimension a for the frame dis-tance must be observed.
• The position of the separator feet is given in section 2.1.1.
Fig. 27
• The dimension a for the frame dis-tance is given in the table below for the respective separator model.
Fig. 28
Separator model Dimension “a” [mm]
OTC 2 452 mm OTC 3 452 mm OTC 5 326 mm OTC 10 350 mm OTC 20 425 mm OSD 2 452 mm OSD 6 350 mm OSD 18 425 mm OSD 35 555 mm OSD 60 700 mm OSE 5 326 mm OSE 10 350 mm OSE 20 425 mm OSE 40 555 mm OSE 80 700 mm
2058-9601-020 / 0211 31
2.8 Vibrations
Fig. 29 model
Tolerable vibration values at the separator installation surface max. [mm/s]
Admissible vibra-tion value at the reference point [mm/s]
Limit values for Vibro 1 with installed vibration sensor [mm/s]
OTC 2 1,8 2,8 2,8
OTC 3 1,8 2,8 2,8
OTC 5 2,8 4,5 4,5
OTC 10 2,8 4,5 4,5
OTC 20 2,8 4,5 4,5
OSD 2 1,8 2,8 2,8
OSD 6 2,8 4,5 4,5
OSD 18 2,8 4,5 4,5
OSD 35 2,8 4,5 4,5
OSD 60 2,8 4,5 4,5
OSE 5 3,5 5,5 5,5
OSE 10 2,8 4,5 4,5
OSE 20 2,8 4,5 4,5
OSE 40 2,8 4,5 4,5
OSE 80 2,8 4,5 4,5
Measured at separator standstill and normal ship operating conditions Measured with separators in operation The Vibro sensor is attached in this range
32 2058-9601-020 / 0211
2.9 Pipelines on the separator
The following sections describe the general set-up of the piping system in the separator installation:
2.9.1 Product line
• Product lines must be laid
– in accordance with the guidelines of GEA Westfalia Separator or
– in accordance with the requirements of the classification societies.
• Use only genuine parts from GEA Westfalia Separator!
• The lines must be flushed before commissioning to protect the valves and units.
• The following lines must have no rigid connection with the separator in order to prevent vibrations:
– Product feed and discharge
– Water connection
– Solids discharge
– Dirty water discharge
– Frame drain
• This can be realised by means of hoses or compensators, whereby there are special requirements for shockproof separators.
• Hose pipes must be laid so that they cannot be twisted, kinked, clamped or rubbed.
• Use only hoses from GEA Westfalia Separator!
2.9.2 Operating, filling and displacement water lines
• Water lines must be laid so that they can be completely drained at the lowest point with no dismantling.
• Y-strainers are fitted horizontally at the factory – with the strainer insert point-ing downwards. See section 1.3 – Installation.
• The solenoid valves for operating, filling and displacement water to the sepa-rator are fitted so that the hose between the separator and solenoid valves cannot empty.
2058-9601-020 / 0211 33
3 Operating, filling and displacement water
3.1 Water quality
3.2 Supply pressure and temperature
3.3 Water connection for operating, filling and displacement water
3.4 Dimensions and number of consumers
3.5 Water quantity
34 2058-9601-020 / 0211
3.1 Water quality
• The water should be as pure as possible and meet the following standards:
Hardness:
– up to 55 °C (131 °F) separating temperature < 12° dH
– above 55 °C (131 °F) separating temperature < 6° dH Note:
– When using demineralised water or condensate, corrosion must be reckoned with.
– The use of boiler feed water is not permissible!
– Land water is not recommended because the degrees of hardness are normally too high.
To convert the hardness values stated, use the following equation:
1° dH = 1,79° fH = 1,25° eH = 17,9 ppm CaCO3 pH 6,5 – 8,5 Chloride ions < 100 mg/l Suspended matter max. 10 mg/l Particle size max. 50 µm
3.2 Supply pressure and temperature
Fig. 30
Note:
The pressure after the water pressure reducer must not drop below 0.2 Mpa with open operating water valve.
• The supply pressure and the temperature for the operating, filling and dis-placement water must meet the following specifications:
Temperature min. 10 °C (50 °F) max. 85 °C (185 °F)
Supply pressure 0.3 – 1.0 MPa
2058-9601-020 / 0211 35
3.3 Water connection for operating, filling and displacement water
• Pay special attention to section 2.9.2!
3.4 Dimensions and number of consumers
• Collective lines must be dimensioned so that the separators are always sup-plied with an adequate water volume to assure perfect functioning.
• Lines must be laid so that manual override of the valves and filter replace-ment are possible.
• The maximum length between pressure reducer and solenoid valve must not exceed 5 m.
• In the case of 1 consumer, the col-lective line must have the same nominal diameter as the feed lines to the separator.
• The nominal diameter R is given in the table below.
Fig. 31
Fig. 32
In the case of 2 consumers:
• the collective line must have a nominal diameter S (see table).
• the supply lines to the separator must have a nominal diameter R (see table).
When two separators request water at different times, the water supply can be rated as for one separator.
36 2058-9601-020 / 0211
In the case of 3 consumers:
• the collective line must have a nominal diameter of DN 32.
• the supply lines to the separator must have a nominal diameter R (see table).
Table for selecting the nominal diameters “S” and “R”.
Separator model Nominal diameter (DN)
Collective line S
Supply line R
OSD 2 25 20
OSD 6 25 20
OSD 18 25 20
OSD 35 32 20
OSD 60 32 20
OSE 5 25 20
OSE 10 25 20
OSE 20 25 20
OSE 40 32 20
OSE 80 32 20
3.5 Water quantity
For exact program control, with simultaneous actuation of the valves, the follow-ing water quantities are required:
V2 V2 V3 Total con-sumption per cycle
Total con-sumption per cycle without filling wa-ter
Filling water Displace-ment water
Operating water l/s l/s l/s Approx. 1
OSD 2 0,25 0,25 0,25 2 1,5
OSD 6 0,1 0,1 0,5 3 2
OSD 18 0,1 0,1 0,8 5 3,5
OSD 35 0,1 0,1 0,8 10 6,5
OSD 60 0,1 0,1 0,8 23 13
OSE 5 0,1 0,1 0,5 1,6 1,1
OSE 10 0,1 0,1 0,5 2,3 1,5
OSE 20 0,1 0,1 0,5 3,2 2,0
OSE 40 0,1 0,1 0,8 11,6 7,6
OSE 80 0,1 0,1 0,8 25,4 15,4
* Ejection cycle = Σ (filling water + displacement water + operating water)
2058-9601-020 / 0211 37
4 Compressed air
4.1 Compressed air quality
4.2 Supply pressure
4.3 Compressed air consumption of the separators OSD, OSE and OTC.. 38
38 2058-9601-020 / 0211
4.1 Compressed air quality
• The compressed air must be free from impurities and dry.
4.2 Supply pressure
Recommended set-up of compressed air line per treatment system.
Fig. 33 OSD separators
• A supply pressure of 0.3 to max. 1.0 MPa is admissible.
• After the reducer station 0.3 MPa must still be available to the consumers.
• Note:
On OSD separators, a compressed air control unit is no longer included in the standard scope of supply.
• If other pneumatic components are operated, the corresponding instructions relating to air quality and air lubrication must be observed.
4.3 Compressed air consumption of the separators OSD, OSE and OTC
• The maximum compressed air consumption per separator is approx. 0.01
Nm3/h.
2058-9601-020 / 0211 39
5 Product lines
5.1 General
5.2 Pipe cross-sections
5.3 Functional description
5.4 Information on pressure monitoring
5.5 Piping
5.6 Maximum suction head
5.6.1 Pressure line
5.6.2 Pre-filter
5.7 Feed pump
5.8 Oil pre-heater
5.9 Installation examples
5.9.1 Steam-heated plate heat exchanger with (PI controlled) control valve . 45
5.9.2 Steam-heated tubular heat exchanger with (PI controlled) control valve
5.9.3 Thermal oil-heated plate heat exchanger with (PI controlled) control valve
5.9.4 Thermal-oil-heated tubular heat exchanger with (PI controlled) control valve
5.10 Securing plate heat exchangers
5.11 Safety valve
40 2058-9601-020 / 0211
5.1 General
• Pay special attention to section 1.3!
• The suction lines should be as short as possible to avoid pressure losses.
• The pipes must be installed with adequate clearance from the electronic parts.
• Water pockets must be avoided! (water must be able to flow off freely).
• When different products are run through the same separator, it must be en-sured that the corresponding product lines cannot be interchanged.
5.2 Pipe cross-sections
• All pipes, valves, fittings and instruments must be laid so that an insulation of
40 mm is possible.
• Dimensioning of the pipes is specified on the respective P&ID.
• The pipes can be selected with the aid of the following diagram. The specifi-cations on the P&IDs have priority!
• Pipe resistances must be kept as low as possible.
• Taking into account the total pressure losses, the flow velocities must be
– between 0.5 m/s and < 1 m/s in suction lines,
– between 1 m/s and 3 m/s in pressure lines.
5.3 Functional description
The liquid is discharged from the separator by means of a pumping device, in the following referred to as centripetal pump. At small capacities, the discharge can be without pressure; in the case of larger capacities the centripetal pump generates the required pressure to convey the liquid out of the separator through the downstream lines by immersing more deeply into the liquid.
The pressure values can differ significantly. The following rule applies: The val-ues are lower on small separators than on large separators.
Further influencing factors are capacity, system resistances (valve position, tank position), product properties and process specifications.
5.4 Information on pressure monitoring
When the liquid is discharged from the separator under pressure, the operator knows that the separator bowl is hydraulically closed.
A discharge pressure adjusts given a constant capacity or it is adjusted to the desired value by throttling in the discharge.
In the standard application, the pressure sensor responds to falling discharge pressure, an alarm is triggered via the control system. The control system can also evaluate rising pressure and trigger an alarm.
Generally, the discharge pressure is set to 0.1 – 0.2 MPa. The pressure level can deviate from this when separator size, capacity, product properties and process specifications require. (for further information, see the order-specific documentation)
2058-9601-020 / 0211 41
A change in the discharge pressure may be caused by the following factors:
• Change in feed capacity
• Change in product data such as temperature, density, viscosity
• Change in discharge resistance
• Leakage at the separator bowl This represents important information for the operator.
Selection diagram
Fig. 34
Q Flow v Velocity in m/s
Example:
A flow rate of 5 m3/h produces a velocity of 1.2 m/s with a nominal diameter of 40.
42 2058-9601-020 / 0211
5.5 Piping
Fig. 35 Lubrication oil schematic
1 LO tank
• When separating lube oil, the return line of the 3/2-way valve can be led into the product discharge line of the separator.
Fig. 36 Diesel oil schematic
1 DO tank 2 Service tank
• When separating diesel oil, the return line of the 3/2-way valve must be led into the DO tank 1.
WS does not permit leading the return line into the suction side of the pump!
2058-9601-020 / 0211 43
Fig. 37 Heavy fuel oil schematic
1 Settling tank 2 Service tank
• When separating heavy oil, the return line of the 3/2-way valve must be led into the settling tank 1.
5.6 Maximum suction head
• The suction head of the feed pump (gear pump) is max. 0.04 Mpa.
• The suction head of the feed pump (screw pump) is max. 0.05 MPa.
• The viscosity of the oil to be conveyed must be kept < 1 000 cSt, if necessary by adequate pre-heating and trace heating.
• When dimensioning the suction line, it must be ensured that the total pressure loss in the pipe does not exceed the maximum suction head of the pump.
• The maximum feed pressure in the suction line must not exceed 0.05 MPa.
5.6.1 Pressure line
• The pressure head of the feed pump is set to approx. 0.3 MPa.
• The pressure line from the feed pump via the pre-set valve, the pre-heater and the 3/2-way valve to the separator must be kept as short as possible.
• When dimensioning the pressure line, it must be ensured that the total pres-sure loss in the pipes does not exceed the maximum pressure head of the pump.
44 2058-9601-020 / 0211
5.6.2 Pre-filter
• The pre-filters are fitted in the suction line of the feed pump to protect it from coarse impurities.
• During the installation, special attention must be paid to the operability.
• Use only strainers with a mesh width of the strainer insert of 1 to 1.25 mm.
• Pay special attention to section 1.3!
Fig. 38
• Use only pre-strainers with a mesh width of the strainer insert of 0.63 mm.
Fig. 39
5.7 Feed pump
To prevent the pre-heater from overheating,
• a pump post-running time must be programmed for pump units and product pre-heating.
5.8 Oil pre-heater
• It must be installed so that there is no heat dissipation to the control cabinet.
To prevent a risk of accidents when venting due to discharging hot va-pours and liquids,
• the discharge lines from vent valves must be laid at least to floor plate height.
• Discharge lines of safety valves must be laid so that there is no danger of accident when the valve responds due to discharging liquid.
• The discharge line must be laid so that it can always be observed. It must not be concealed by pipes, valves or other units!
2058-9601-020 / 0211 45
• Steam traps
– must be fitted horizontally between two unions.
– should not be insulated to assure correct functioning.
– must be installed so that no condensate accumulation can occur on the pre-heaters.
5.9 Installation examples
The following sections show installation examples for
– Tubular heat exchanger
– Steam-heated plate heat exchanger with (PI controlled) control valve
– Steam-heated tubular heat exchanger with (PI controlled) control valve
– Thermal oil-heated plate heat exchanger with (PI controlled) control valve
– Thermal-oil-heated tubular heat exchanger with (PI controlled) control valve
5.9.1 Steam-heated plate heat exchanger with (PI controlled) control valve
Fig. 40
A Oil inlet 0.1 Spring safety valve B Oil outlet 1.0 Plate heat exchanger C Steam inlet 1.1 Resistance thermometer (PT 100) D Condensate outlet 2.1 Strainer
2.2 Motor control valve
2.3 Ball float condensate trap
46 2058-9601-020 / 0211
5.9.2 Steam-heated tubular heat exchanger with (PI controlled) control
Fig. 41
B Oil outlet 1.0 Tubular heat exchanger C Steam inlet 1.1 Resistance thermometer (PT 100) D Condensate outlet 2.1 Strainer
2.2 Motor control valve
2.3 Ball float condensate trap
2058-9601-020 / 0211 47
5.9.3 Thermal oil-heated plate heat exchanger with (PI controlled) control
Fig. 42
B Oil outlet 1.0 Plate heat exchanger C Thermal oil inlet 1.1 Resistance thermometer (PT 100) D Thermal oil outlet 2.1 Motor control valve
48 2058-9601-020 / 0211
5.9.4 Thermal-oil-heated tubular heat exchanger with (PI controlled) control valve
Fig. 43
B Oil outlet 1.0 Tubular heat exchanger C Thermal oil inlet 1.1 Resistance thermometer (PT 100) D Thermal oil outlet 2.1 Motor control valve
2058-9601-020 / 0211 49
5.10 Securing plate heat exchangers
Assembly instructions for soldered plate heat exchanger
• Prepare an assembly plate support and weld it to the foundation.
• Fasten assembly plate 50 with screws 70 and nuts 80 to the as-sembly plate support.
The assembly plate must be in-stalled vertically relative to the pipe axis.
IMPORTANT:
Welding the assembly plate to the support is not permitted.
• Fasten heat exchanger with gaskets 40 counterflanges 30, lock washers 20 and screws 10 to the assembly plate.
• Attach the pipes to the counter-flanges by tack-welding.
• Dismantle the heat exchanger and gaskets.
• Completely weld the pipes to the counterflanges.
• Finally, re-assemble the parts as per instruction.
Fig. 44
A The illustrated channel steel must be provided by the shipyard.
B GEA Westfalia Separator recommendation as example channel steel ac-cording to DIN1026-1-50.
Distortion or warping or other stress of the soldered connection points must be avoided!
Pipelines must be correspondingly arrested.
Pos./ type
10 20 30 40 50 70 80 Allen screw Lock washer Groove-faced flange
Gasket Plate Hex head screw
Hexagon nut
B 10
ISO 4762 -
M10 x 45 (16 x)
DIN127 -
B10
1 in -
SAE3000P
SI
(4 x)
32.92 x 3.53 (8 x)
352 x 125 x (1 x)
ISO 4017 -
M12 x 40 (2 x)
ISO 3032 -
M12
B 45
ISO 4762 -
M12 x 55
DIN127 -
B12
2 in -
SAE3000P
SI
(4 x)
56.74 x 3.53 (8 x)
563 x 290 x (1 x)
ISO 4017 -
M12 x 40
ISO 3032 -
M12
50 2058-9601-020 / 0211
5.11 Safety valve
Safety valve in vertical fitting posi-tion
Fig. 45
• The safety valve outlet should be led via a funnel (pos. “1”).
A discharge line is welded to the funnel via which the medium can be discharged.
• Do not use galvanized compo-nents and hoses.
Fig. 46
2058-9601-020 / 0211 51
6 Solids tank
6.1 Recommended criteria for solids tank
6.1.1 Tank vent
6.1.2 Set-up of the solids tank venting
6.2 Solids discharge lines
6.2.1 Solids discharge lines with shut-off flap
6.2.2 Standard installation of shut-off flaps
6.2.3 Installation recommendation for shut-off flaps
6.3 Operating and dirty water discharge lines
6.3.1 Separators of OSD and OSE
52 2058-9601-020 / 0211
6.1 Recommended criteria for solids tank
This information does not apply to sludge transfer units on compact units.
• There should always be separate solids tanks for the lube oil and fuel sys-tems.
• Tank heating should be installed in dependence of the viscosity or ambient temperature.
• The general designs and constructions are subject to the valid regulations.
1 Monitoring 2 Venting 3 Tank heating 4 Utilizable volume
Fig. 47
Minimum solids tank volume
Separator model Volume [l]
Maximum utilizable volume
OSD 2 80 60
OSD 6 200 60
OSD 18 200 60
OSD 35 300 60
OSD 60 300 60
OSE 5 80 60
OSE 10 200 60
OSE 20 200 60
OSE 40 300 60
OSE 80 300 60
2058-9601-020 / 0211 53
6.1.1 Tank vent
• In the case of one or more separators which are connected to a solids tank, the nominal widths DN to be used are given in the table below:
Connect the tank vent to the on-board venting system.
Separators per solids tank
Tank vent DN in mm
OSD 2 OSD 6 OSD 18 OSD 35 OSD 60
1 50 80 80 125 125 2 50 100 100 150 150 ≥3 80 125 125 150 150
OSE 5 OSE 10 OSE 20 OSE 40 OSE 80
1 50 80 80 125 125 2 50 100 100 150 150 ≥3 80 125 125 150 150
• In the case of a combination of separator models on one solids tank
– the total number of all separators must be taken as a basis
– and the nominal width of the largest model used.
The following criteria must be taken into consideration when venting the tank:
• Installation in accordance with the guidelines of the classification societies
• Controlled discharge of oil vapours
• An uncontrolled discharge of the sludge must be avoided.
• The vent lines must be laid so that a chimney effect develops.
• All possible loops in the vent lines must be stepwise.
54 2058-9601-020 / 0211
6.1.2 Set-up of the solids tank venting
Solids tank with one separator
• The nominal width DN is given in the table above (section 6.1.1).
Fig. 48
Solids tank with several separators
• The nominal width DN is given in the table above (section 6.1.1).
Fig. 49
Solids tank with wash plates
A solids tank with wash plates is re-quired when movements of the ship cause faulty functioning of the level monitoring.
• When using wash plates, each sec-tion must be vented.
• The vent lines must be brought to-gether.
Fig. 50
2058-9601-020 / 0211 55
6.2 Solids discharge lines
• The solids discharge lines should always be vertical if possible.
• The solids discharge must always end 50 – 100 mm below the tank top.
• The maximum level in the solids tank must be monitored by means of a float switch.
• The piping for the solids discharge should be without reduction and with vibration compensators.
• The length of 2 m may not be ex-ceeded without trace heating.
Fig. 51
• If there is a deviation from the verti-cal, an angle of 45° must not be ex-ceeded.
Fig. 52
• This piping arrangement is not ad-missible!
Fig. 53
56 2058-9601-020 / 0211
6.2.1 Solids discharge lines with shut-off flap
• A shut-off flap in the solids discharge line prevents the penetration of vapours into a stationary separator during the desludging of another separator.
• If more than one separator is used for a sludge tank, a shut-off flap must be installed in the sludge discharge at the shipyard.
• Shut-off flaps are not included in the standard scope of supply of GEA West-falia Separator but can be ordered from GEA Westfalia Separator.
• CP units or modules equipped with a sludge tank supplied by GEA Westfalia Separator and equipped with more than one separator are always delivered with shut-off flaps.
6.2.2 Standard installation of shut-off flaps
Separators of OSD and OSE
Fig. 54
I
II
Solids discharge Hood and frame drain
III
IV
Tank vent Shut-off flap
• Discharges I, and III must be configured as illustrated in Fig. 57.
• See section 6.1.1, table for tank vent connection.
It must be ensured that the shut-off flaps are open during separator operation.
2058-9601-020 / 0211 57
6.2.3 Installation recommendation for shut-off flaps
• The solids discharge must always end below the tank top.
• For dimension X, see section 6.2, Fig. 51.
I Shut-off flap II Flange III Pipe IV Hose (supplied with separator) V Solids tank cover
Fig. 55
Fig. 56
58 2058-9601-020 / 0211
6.3 Operating and dirty water discharge lines
• The discharges for operating and dirty water can be conveyed into a separate tank for oily water.
• The piping for the operating and dirty water discharge should be vertical, without reduction and with vibration compensators. There is no upper length limit.
Operating and dirty water discharges may not be discharged into public canals, draining ditches and waters!
6.3.1 Separators of OSD, OSE and OTC
• The water discharges must be sub-merged under all conditions (roll/pitch).
• Dimension h is:
– min. 50 mm for shipboard opera-tion,
– min. 20 mm for stationary plants.
I Hood and frame drain II Solids discharge III Tank vent
Fig. 57
• When a siphon is installed, the frame drain need not be submerged below the minimum level because a liquid seal is assured.
• Dimension h1 is given in the table below.
I Solids discharge II Hood and frame drain III Tank vent IV Siphon for hood and frame drain
Fig. 58
2058-9601-020 / 0211 59
Table for defining siphon length, dimension “h1”
Separator model Siphon length [mm] h1
OSD 6 / OSD 18 500
OSD 35 / OSD 60 800
OSE 5 500
OSE 10 500
OSE 20 500
OSE 40 800
OSE 80 800
OTC 2 –
OTC 3 –
OTC 5 –
OTC 10 –
OTC 20 –
60 2058-9601-020 / 0211
NNoottiizzeenn AAnnoottaacciioonneess ДДлляя ззааппииссеейй MMuuiissttiiiinnppaannoott ΣΣηημμεειιώώσσεειιςς
NNoottaatteerr
2058-9601-020 / 0211 61
7 Electrical installation
7.1 Control cabinet
7.1.1 Electrical connection
7.1.2 External voltages
7.1.3 Shipboard operation
7.1.4 Onshore operation
7.2 Electro-magnetically compatible installation
7.3 Valves
7.3.1 Solenoid valve block
7.3.2 Terminal box
7.3.3 Separator with sensor bloc
7.4 Dual-purpose thermometer
7.5 Electrical installation of transmitters and electric motors
7.6 Electrical execution
7.6.1 Earthing the separator
7.6.2 Voltage equalisation of the separator
7.6.3 Voltage equalization of the electric heater
7.6.4 Voltage equalization of the foundation frame
7.6.5 Voltage equalisation of the control cabinet
7.7 Electric motors procured by the customer
7.8 Installation and operation of control units
62 2058-9601-020 / 0211
7.1 Control cabinet
Control cabinet configuration
1 Lock
2 Control Unit D10
3 OFF/ON keys for separator
4 OFF/ON keys for feed pump
5 HAND/0/AUTOMATIC selector for solids pump (option)
6 Main switch
Fig. 59 Front view
Fig. 60 Interior view
1 Isolating amplifier for analog output (option) 2 WMS (Water Content Monitoring System) relay, if provided 3 Full-motor-protection module 4 Interface relay 5 Auxiliary contactor 6 Main contactor 7 Current transformer 8 Power supply for PLC (Programmable Logic Control) and valves 9 Terminal Strip
10 Control transformer for heating and venting facilities (option) 11 Main switch 12 Control voltage transformer (option) 13 Motor protection switch 14 Safety outcut
2058-9601-020 / 0211 63
Mounting example
Gasket 10,5x23x5 Threaded bolt M 8 (embedded in the wall) Washer Rear panel of control cabinet Washer Wall
Fig. 61
• The control cabinet
– must be allocated to the corresponding separator by means of its designa-tion.
– must be mounted on a frame or wall in the vicinity of the separator.
– conforms to enclosure IP 54.
• It must be possible to open the control cabinet door wide so that the door latch can lock into place.
• Select the installation site so that
– it can be easily operated and observed.
– an ambient temperature of 50 °C (122 °F) is not exceeded. If necessary, make sure there is an adequate supply of fresh air.
• If the control cabinet is mounted on a wall, a wall clearance of 20 m must be observed to achieve a vibration-free fastening arrangement.
• Although buttons and switches and the electronic control unit are protected against moisture by protective foil and door seal, the cabinet must neverthe-less not be installed in an excessively humid environment or damp area.
• To keep the temperature inside the unit constant after commissioning, the main switch should be kept turned on even when the separator is at a stand-still.
64 2058-9601-020 / 0211
7.1.1 Electrical connection
• The control unit is designed for a connected voltage as indicated on the nameplate inside the control cabinet.
• In the case of a version without motor starter, the rated connection voltage is 115 VAC or 230 VAC which must be protected by a 6 A slow-blow fuse.
7.1.2 External voltages
– carry external voltage (even when the main switch is off!).
– can be identified by the orange coloured wiring.
– can be used in external control systems up to 250 VAC.
• A cross-section of 1.5 mm2 Cu is adequate for all control and interlocking lines.
• The voltage-free contacts of the output modules
2058-9601-020 / 0211 65
7.1.3 Shipboard operation
• For shipboard operation
– Only lines type "MGCH" according to DIN 89 158 may be used.
– All cables must meet the flame test requirements for bunched cables acc.
to IEC 60332-3 / IEEE 45-18.13.
– All cable materials must be free of halogens acc. to IEC 60754-1, no toxicity acc. to 60754 and no corrosivity acc. to IEC 60754-2.
– All cables must have an approval of the relevant classification society.
– Insulating strength: 0.6/1KV
– GEA WSPN Standard: Nexans MPRX 0.6/1kV
– The standard control cabinets are equipped with plastic non halogen oil resident. WS standart is “Ernst Heinrich GmbH”
– load and control lines can be laid jointly without clearance
• In the case of HFO separators in series operation, the signal exchange be-tween the control cabinets as per the terminal diagram for the connecting ca-ble must be taken into account (see section 7.2).
Cable glands for shipboard installation
Female thread
∅ Cable outer [mm] Cable gland Earthing device +
Inner parts design
M 16 x 1.5 4 – 11 M 24 x 1.5 M 20 x 1.5 8 – 13 M 24 x 1.5 M 25 x 1.5 11 – 17 M 36 x 1.5 M 32 x 1.5 15 – 21 M 36 x 1.5 M 40 x 1.5 19 – 28 M 36 x 1.5
7.1.4 Onshore operation
• The local rules and regulations of the operator must be observed!
• for onshore operation
– Normally, "ölflex" cables are used and "NSSHÖU" for outside installation.
– commercially available cable glands can be used.
– separate cable routing must be used for the load and control lines.
• Cable entries with plastic or metal glands are admissible.
66 2058-9601-020 / 0211
7.2 Electro-magnetically compatible installation
• The control cabinet is designed to be electro-magnetically compatible.
• The following must be taken into account with electro-magnetically compatible installations:
– Earthing straps
– Voltage equalization
– Screening lines
– Separate line routing
– Use of erase elements in case of inductance.
In the case of HFO series operation, proceed in accordance with the following wiring diagram:
Fig. 62
A Switch ON D Connecting terminals B Control cabinet HFO No. 1 F Cable type C Control cabinet HFO No. 2 E Customer shipboard installation
• Use only data cable UNITRONIC-BUS-FD P L2/F.I.P (1 x 2 x 0.25 mm² +
Screen).
• Do not lay data cables directly next to load cables as this can cause prob-lems with electromagnetic compatibility.
• Pay attention to the different software status on the C7 units:
– 1. unit has the MPI addresses 1 / 2
– 2. unit has the MPI addresses 3 / 4
– 3. unit has the MPI addresses 5 / 6
• Faulty or broken cable connections are displayed with error code no. 551.
• Check all connections.
2058-9601-020 / 0211 67
7.3 Valves
Only original valves from GEA Westfalia Separator with integrated suppressor diode and reverse battery protection in the connection head may be used in filling, displacement and operating water lines.
7.3.1 Solenoid valve block
This diagram shows an original valve block from GEA Westfalia Separator which is used in filling, displacement and operating water lines.
Fig. 63
Connections
A B C D
Connecting terminal + 24 V DC Connecting terminal + 0 V DC Earth Status LED
Fig. 64
68 2058-9601-020 / 0211
7.3.2 Terminal box
All valves and monitoring instruments are installed ready-to-connect on a local terminal box at the separator.
• The connection to the control cabi-net must be carried out by means of a joint cable in accordance with the adjacent connection diagram.
A Control cabinet B Product discharge pressure C “Self-Think” system D Water sensor E Circuit valve F Water discharge valve G Filling, displacement water valve H Operating water valve I Circulation valve J Operating Water K Filling, displacement water
Fig. 65
2058-9601-020 / 0211 69
7.3.3 Separator with sensor bloc
Fig. 66
The components on the hood are wired to the terminal box.
70 2058-9601-020 / 0211
7.4 Dual-purpose thermometer
• The dual-purpose thermometer is used
– to monitor the temperature of the dirty oil after the pre-heater and
– for local temperature indication.
ATTENTION!
• The dual-purpose thermometer is used only in conjunction with a C7 control system.
Fig. 67 Fig. 68
• The dual-purpose thermometer must always be fitted before the 3-way piston control valve.
• All sensors must be installed so that they are continuously flushed with oil.
2058-9601-020 / 0211 71
7.5 Electrical installation of transmitters and electric motors
• The connection of motors and transmitters by means of cable loop enables easy replacement and function testing of the components.
Example 1
Fig. 69
Example 2
Fig. 70
7.6 Electrical execution
The electrical execution must be in accordance with the following standards and recommendations in so far as specifications and standards issued by the classi-fication societies do not have to be met.
The applicable standards at GEA Westfalia Separator are
– the European…