SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
The following have been modified:
C – 2 List of Standard Work Items included for this solicitation:
NOT SEPARTELY PRICES ITEMS
INTENT, SCOPE GENERAL CONDITIONS & DEFINITIONS
TECHNICAL AND MANUFACTURER’S REPRESENTATIVES
APPROACH, BERTH, AND MOORING REQUIREMENTS
TESTING AND QUALITY ASSURANCE
ELECTRICAL SAFTEY PROCEDURE REQUIREMENTS
HEAVY WEATHER PLAN
COLD WEATHER PLAN
PHYSICAL SECURITY OF VESSEL
CATEGORY A ITEMS
FURNISH OFFICE FOR OVERHAUL MANAGEMENT TEAM (OMT)
FURNISH GENERAL SERVICES (T-AKE)
TELEPHONE SERVICES
PROJECT PLANNING AND PRODUCTION STATUS MONITORING REPORTS
PREPARATION OF WEIGHT AND MOMENT REPORT
INTEGRATED LOGISTICS AND GFM SUPPORT REQUIREMENTS
FIRE PROTECTION AND SHIP'S SAFETY PROGRAM
HANDLING SHIP'S STORES
DELIVERY AND REDELIVERY OF THE VESSEL
SHIPBOARD ACCESS AND SECURITY
GAS FREE CERTIFICATES
CLEAN AND GAS FREE TANKS, VOIDS, COFFERDAMS & SPACES
DOCK TRIALS AND SEA TRIALS
HAZARDOUS WASTE DISPOSAL AT A CONTRACTOR'S FACILITY
PHYSICAL SECURITY OF VESSEL
BALLAST TANK ZINC INSPECTION
OPEN, CLEAN, AND INSPECT TANK VENT GOOSENECKS
DECKHOUSE PRESERVATION – SPOT BLAST
HULL GAUGING-LIMITED SUSPECT AREAS-ABS
TANK PRESERVATION (VRR15-028)
SHELL AND DECK STEEL REPLACEMENT
PROPULSION MOTOR AND COOLER CLEANING
MAIN ENGINE FLEXIBLE CONNECTION REPLACEMENT (5-YR)
MDE CONTROL SAFETY INSPECTION AND TEST
AUTOMATION AND PROPULSION CONTROL INSPECTION AND TEST
VULKAN COUPLING ANNUAL INSPECTION
MDE 12K OVERHAUL
MDE SPLASH OIL AND TEST CIRCUIT MOD (T-ALT 381)
MDE FUEL OIL FLEX PIPING REPLACEMENT (T-ALT 449)
301A
"CLEANING MAIN GENERATORS, FREQUENCY CONVERTERS,
PROPULSION TRANSFORMERS, AND HARMONIC FILTERS"
HV/SS/EMER SWITCHBOARD CLEANING
HIGH VOLTAGE CRIMP CONNECTOR INSPECTION
AEES UPS UPGRADE (T-ALT 434)
SACOS UPS UPGRADE (T-ALT 352)
EMERGENCY SWITCHBOARD MODIFICATIONS (T-ALT 154)
UPS FOR TELEPHONE, PA, AND GA (T-ALT 323)
BRIDGE AND NAV EQUIPMENT PM AND ANNUALS
ANTENNA PREVENTIVE MAINTENANCE
COMMUNICATION SUITE PM AND REPAIRS
OE-570 SATCOM ANTENNA SYSTEM PM
SRD-500 DOPPLER REPLACEMENT (T-ALT 431)
SSAS REPLACEMENT (T-ALT 438)
501B
FIRE FIGHTING INSPECTION AND TESTING (5-YR)
SCBA ANNUAL INSPECTION AND TESTING
"SCBA AIR COMPRESSOR AND RE-FILLING STATION INSPECTION
AND MAINTENANCE"
504A
APPLETON CRANE 5-YR INSPECTION AND TESTING
EDG 5-YR INSPECTION, MAINTENANCE, AND TESTING
EDG 5-YR HOSE REPLACEMENT
DISTILLER CLEANING, INSPECTION, AND MAINTENANCE
512B
MAGAZINE SPRINKLER GAUGE CALIBRATION
RELIEF VALVE TESTING
HP AIR RECEIVERS TESTING AND CERTIFICATION
SEWAGE PIPING SYSTEM CLEANING
BRINE SYSTEM FLUSH
528B
MAGAZINE SPRINKLER OVERHAUL (T-AKE 10-14)
SEWAGE TREATMENT ROOM FIREMAIN FLUSHING VALVE REPLACE (T-ALT 336)
SEWAGE DISCHARGE FLUSHING (T-ALT 167)
VCHT CHECK VALVE INSTALLATION (T-ALT 362)
LTFW COOLER SW PIPING MODS (T-ALT 238)
OILY WATER SEPERATOR GROOM AND TESTING
DOMESTIC FISH/FREEZER DOOR HEATER REPLACEMENT (VRR15-029)
CYCLONE SEPARATOR VALVE REPLACEMENT (VRR15-034)
CARGO REEFER FLEXIBLE BOOT REPLACEMENT (VRR15-047)
VCHT PIPING REPAIRS (VRR-16-005)
AFFF HANGAR SPRINKLER MODIFICATIONS (VRR15-044)
ACCOM LADDER INSPECTION AND LOAD TESTING (5-YR)
LIFEBOAT CERTIFICATION AND FALLS RENEWAL (5-YR)
RHIB MAINTENANCE AND FALLS RENEWAL (5-YR)
LIFERAFT ANNUAL CERTIFICATION
FLIGHT DECK NON-SKID RENEWAL
GALLEY EQUIPMENT CALIBRATION
STATEROOM DECK HEAD RENEWAL
HELO DECK FLIGHT DECK HATCH PRESERVATION (VR15-008)
RHIB SPONSON REPARIS (VRR16-019)
COSAL STOREROOM VIDMAR MOUNTING
GALLEY AND LAUNDRY EXHAUST DUCT CLEANING
FAN ROOM REINSULATION AND REPAIRS (VRR15-031)
LOUVER MESH FRAMES (VRR15-032)
DRY DOCKING / UNDOCKING VESSEL
903C
PROPELLER SHAFT AND STERN TUBE INSPECTION
STERN TUBE SEAL INSPECTION
905B
BOWTHRUSTER MAINTENANCE (5-YR)
POLISH BOWTHRUSTER PROPELLER
RENEW SEACHEST, ROPE GUARD AND BOWTHRUSTER ZINCS
ANCHOR CHAIN RANGING
OVERHAUL SEA VALVES
INSPECT AND REPAIR CATHODIC PROTECTION
SHAFT GROUNDING & BRUSH PREVENTATIVE MAINTENANCE
RENEW WASTER PIECES
UNDERWATER HULL CLEANING AND PAINTING – SPOT BLAST
FREEBOARD CLEANING AND PAINTING – SPOT BLAST
REVERSE OSMOSIS UNIT SEACHEST INSTALLATION
BOW THRUSTER TRASH BAR MODIFICATIONS
FIREMAIN OVERBOARD PIPING RENEWAL & CORD REPLACEMENT
EMERGENCY BILGE SUCTION RECONDITIONING (VRR15-037)
SEAWATER HEADER TRANSDUCER REPLACEMENT (VRR16-017)
FIREMAIN PRESSURE TRANSDUCER REPLACEMENT (VRR16-001)
SLIDING BLOCK CHAIN REPLACEMENT
CATEGORY B ITEMS
PHYSICAL SECURITY AT PRIVATE CONTRACTORS FACILITY FP B-D
CONTINUATION OF SERVICES
DRYDOCK EXTENSION
(End of Summary of Changes)