This file is an extensive archive of technical documentation for the Naval Radio Transmitter Facility (NRTF) in Grindavik, Iceland, containing over 300 detailed documents related to transmitters, antennas, generators, test equipment, facility systems, and operational procedures. The documentation covers multiple systems including AN/FRT-95A and AN/FRT-72C radio transmitting sets, with comprehensive manuals spanning maintenance instructions, operation guidelines, technical specifications, installation drawings, and equipment logs dating from 1980 to 2023.
The archive includes critical technical resources such as operational and maintenance manuals for radio frequency transmitters, power systems, dehydrators, facility infrastructure, test equipment, fire systems, and safety protocols. Notably, the documents cover various technical domains including electronic circuits, power distribution, environmental controls, communication systems, and facility management, providing a comprehensive technical reference repository for the NRTF facility. The materials are meticulously organized across multiple series including general documents, test equipment, facility drawings, reports, military standards, and operational logs, reflecting a systematic approach to technical documentation and facility management.
View the file
Other files for this federal contract opportunity
Show all 30
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Archive & supers
| Obsolete documents | Date of cancelation | Old nbr | Title & other info | Column1 | Vendor | Quant. |
| 2006 | 268 | AN/FRT-96 Radio Frequency Transmitter, intermediate Maintenance | Rockwell International | Antenna | ||
| 2006 | 196 | Operational and Maintenance Instructions with Illustrated Parts Breakdown Organizational Level, Processor, Digital Data CP-1071A/WR, CP-1071B/WR, CP-1072A/AR, AND CP-1072B/AR | Obsolete | Transmitters and Antennas | ||
| 2006 | 195 | Remote Control Unit (PN 89-25849-001) for the Transmitting Set, Radio AN/FRT-95A VLF/LF Transmitter and Antenna Matching Subsystem | SPAWAR | Transmitters and Antennas | ||
| 10-2-7 | 2006 | 148 | AN/FRT-95A MRC´s - EE140-NA-PRO-020/FRT-95A | SPAWAR | Antenna | |
| 10-2-8 | 2006 | 149 | AN/FRT-95A Transmitter and Antenna Matching Equipment Local Maintenance Procedures, EE140-NA-PRO-020/FRT-95A | SPAWAR | Antenna | |
| 2006 | 187 | Operation Manual and Maintenance Manual, Generator Set U.S. Naval Station Grindavik, Diesel Enginesm Catepillar | Catepillar | Facility | ||
| 2006 | 188 | Operation & Maintenace Manual for Globecom Transmitter Facilities Grindavik Site, 1955 | Eastern Ocean District Corps of Engineers | Facility | ||
| 2006 | 192 | Instruction Manual SRM60 Automatic Synchronizer | Konell Inernational | GEN OBSOLETE | ||
| 2006 | 193 | Frequency Trimmer | Woodward Govener Company | Facility | ||
| 2006 | 166 | ADNX Users Manual, Technincal Documentation, Integrated Digital Network Exchange Document Set Master Reference, Part Number 023736 | Network Equipment Technology | IDNX | ||
| 2006 | 166-b | ADNX Users Manual, Technincal Documentation, Integrated Digital Network Exchange Document Set Master Reference, Part Number 009114A | IDNX | |||
| 40-2-1 | 2016 | Instruction Manual for Carter Machinery Corporation, Inc., 13644-02 | Gen | 1 | ||
| 40-2-2 | 2016 | Grindavik Transmitter Site, Conversion from 60 Hz to 50 Hz, Materials Only Submittal Package | Gen | 1 | ||
| 40-2-3 | 2016 | Operation and Maintenance Manual Switchboard Power Plant Grindavik, Iceland | GEN | 2 | ||
| 40-2-4 | 2016 | TM5-6115-593-12 Operator Maitenance Manual GENERATOR SET, DIESEL ENGINE 500KW DOD Model MEP-029A | 21-Sep-81 | 1 | ||
| 40-2-5 | 2016 | TM5-6115-593-24P Maintenace ReapairParts/Special Tools. TM5-6115-593-34 Maitenance Manual GENERATOR SET, DIESEL ENGINE 500KW DOD Model MEP-029A | 21.sep 1979 | 1 | ||
| 40-2-6 | 2016 | Grindavik Transmitter site. Conversion from 60Hz to 50Hz. Control Drawing Package. | June 99 | 1 | ||
| 40-2-7 | 2016 | SPM Synchronizer. Manual for 82444C | 1 | |||
| 40-2-8 | 2016 | Submittal Data for Switchgear. NRTF Grindavik. SE Solid State Strip Circuit Breakers. | 1 | |||
| 40-2-9 | 2016 | Power Improvements, Power Building (2608). U.S. Naval Communication Station Grindavik, Iceland. | 1 | |||
| 40-2-10 | 2016 | Certificate of Generator Switchboard and Operating Sequence. Power Improvement, Power building 2608. U.S. Naval Communication Station Grindavik, Iceland | 1 | |||
| 40-2-12 | 2016 | Generator Test Report 1993. Submittal Booklet. Generator Switchboard. Drawings,Bill of Materials and Catalog Data | 1 | |||
| 40-0-26 | 2017 | SE Solid State Trip Circuit Breaker with micrologic trip unit. Manual 678-1 | Square D Company | 1988 | ||
| 40-0-27 | 2017 | Field Test procedure Ground Fault protection system. For SE Circuit Breakers with micrologic Trip Units. Manual 678-2 | Square D Company | |||
| 40-0-28 | 2017 | Instruction information Series 3B. SE Electronic Trip Circuit Breakers with Micrologic Trip System. | Square D Company | Sep-94 | ||
| 40-0-29 | 2017 | Vicon Instructions, Installaton and Operation for Univ. Outdoor receiver and it´s equipmenets | Vicon Industries | |||
| 40-0-34 | 2017 | Westinghouse Type DB Circuit Breakers & Accessories for Switchboard Assdemblers | Westinghouse Electrci corp | nov 1965 | ||
| 40-0-3 | 2017 | T-35, T-46, T-50, VT-50, ST-50 and T-18A Turbochargers Component Shop Manual | Cummins | |||
| 40-0-5 | 2017 | SE Electronics Trip Circuit Breaker w. Micrologic Trip System. Instruction Bulletin. | Cedar Rapids | oct. 1997 | ||
| 40-0-10 | 2017 | Repair Power Distribution Grindavik. Main Panel 1989 | 1989 | 2 | ||
| 40-0-11 | 2017 | Residential Instruction Manual for Electric Water Heaters (bldg 2606) | 1 | |||
| 40-0-1 | 2017 | Instruction Manual LE; ME and NE Electronic Trip Circuit Breakers with Micrologic Trip System | Square D Company | fac | 1 | |
| 40-1-2 | 2/26/19 | 10000SE / 15000SE Dehydrator Installation and Operating Instructions | Dielectirc Communicatiions | Dehydrator | 1 | |
| 40-1-3 | 2/26/19 | Air Dryer - Installations and Operation Instuctins - 5000SE - 10000SE - 150000SE | Dielectirc Communicatiions | Dehydrator | 1 | |
| 40-1-4 | 2/26/19 | Maintenance and field Repair instructions for Dielectric DC-Q Seriies Water Sealed Rotary Air Compressors | Dielectirc Communicatiions | Dehydrator | 1 | |
| 40-1-7 | 2/26/19 | Air Dryer Maintenance Record Models 5000/10000/15000ME/SE (50Hz) | Dielectric Communications | 1 | ||
| 40-1-8 | 2/26/19 | Air Dryer Spare Part List | Dielectric Communications | 1 | ||
| 40-1-9 | 2/26/19 | Main Transmission LineAir Pressure System. AN/FRT-95A. Secondary Line Pressure System | 1 |
| Doc in storage | Date | Storage number Box | Column1 | Vendor | Category | cmts | Column2 |
| 10-2-10 | 146 | AN/FRT-95A Training Outline - Training Guide | SPAWAR | Antenna | 3 in storage | ||
| 10-3-2 | Installation Drawings, VLF/LF Transmitters | Antenna | 1 in storage | ||||
| 197 | Hazardous Waste Management Plan. NASKEFINST 5090.1A | Public Works | |||||
| 246 | Physical Security and Loss Preventin Plan. NAVCOMTELSTAICEINST 5530.2B | IDF | SECURITY |
| 217 | Navcommstaiceinst 5100.1F, Chapter 15 - Hazardous Material Control Program | DON | 1.jul 1991 | Safety | Archive |
| 247 | NAVCOMTELSTAICEINST 5511.4J, | Archive | |||
| 129 | Opnav P-45-110-96 Hazardous Material User´s Guide - HMUG | DON | Oct. 1996 | Safety | cancelation. New document OPNAVINST5530.28 |
| í hillu merkt: Archive but interesting | NAVCOMTELSTAICEINST 5100.1H - Occupational safety and health (OSH) program | DOD | 23.dec. 1999 | Safety | Archive |
| í hillu merkt: Archive but interesting | NAVCOMTELSTAICEINST 5100.4L -Equipment Tag out Bill | 29.june 1999 | Safety | Archive | |
| í hillu merkt: Archive but interesting | NAVCOMTELSTAICEINST 4790.1K - Policies and Procedures for Material and Maintenance (3-M) System | Archive |
NRTF Library Inv
| Series 10- Transmitters & Antennas | |||||||
| 10-0 | General Documents | ||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | |
| 10-0-1 | DELETED | ||||||
| 10-0-2 | Isolation Transformer Manual A-9600, 240/380/480 V Inputs, 120/240 V Outputs | Racal-Decca Canada LTD | 2 | ||||
| 10-0-3 | N62 Antennas, Local SOPs & PMS - Antenna Inspection Checklist | ||||||
| 10-0-4 | R-2368(V)1/URR Radio Receiver, Instruction Manual | Harris RF-Communication | |||||
| 10-0-5 | A-9600/5698 Isolation Transformer Manual | Litton Marine Systems, Canada | 2 | ||||
| 10-0-6 | 3005 Low Profile Spira-Cone Antenna Installation and Maintenance | Andrew | Antenna | 1 | |||
| 10-0-7 | Antenna Field | Antenna | 1 | All kinds of info | |||
| 10-0-8 | SOVT for PDU installation. NCTAMS LANT DET ICELAND. Doc no:0519259 | DOD | 9/1/09 | 1 | Test Verification | ||
| 10-0-9 | PMS REVISION JULY 2010 FOR AN/FRT-95A & AN/FRT-72C LF TRANSMITTERS | SPAWAR | JULY 2010 | Antenna | 1 CD | PMS | |
| 10-0-10 | Galaxy UPS. Service & adjustment manual | Nova Electr.corp | Antenna | 1 | |||
| 10-0-11 | Galaxy UPS. Rack Mount Version. Manual. Installation, Operation and Maintenance | Nova Electr.corp | 1/1/00 | 1 |
| 10-1 | AN/FRT-72C | ||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | |
| 10-1-1 | AN/FRT-72C PMS | SPAWAR | 22. sept.2009. (july2010) | Antenna | 1 | ||
| 10-1-2 | Radio Transmitting Set, AN/FRT-72C; Operation and Maintenance Manual, With Parts List, SPAWAR EE140-AL-OLP-010 | SPAWAR | 9/30/06 | Antenna | 2 | 2 in storage | |
| 10-1-3 | Technical Manual Power Amplifier, Model S11-64E, s/n 3016-3019 | Instruments INC | 9/1/03 | 2 | |||
| 10-1-4 | CD with Radio Transmitting Set, AN/FRT-72C; Operation and Maintenance Manual, With Parts List, SPAWAR EE140-AL-OLP-010 | Antenna | 2 cd´s | ||||
| 10-1-5 | Kintronics Model DL-200WP-318(N) Weatherproof VLF Dummy Load Handbook NISE East Charleston, south carolina. PTS 040 | Kintonic Laboratoires, inc | Antenna | ||||
| 10-1-6 | Technical Manual for Radio Transmitting Set AN/FRT-72C | SPAWAR | Antenna | ||||
| 10-1-7 | Installation Instructions for Austin Isolation Transformer A-9600A/8123 | Austin Insulators inc. | february 2007 | ||||
| 10-1-8 | Installation & Maintenance Instrucitons for A-L810. Austin LED Steady-Burning Red Obstruction Light. Dual Voltage-Low Power Consumption using North American Standards | Austin Insulators inc. | Mar24, 2006 | ||||
| 10-1-9 | History of 600ft.AN/FRT-72C Tower. Ref & install. | 6/5/05 | Antenna | 1 | |||
| 10-1-10 | Technical Manual for Electrical Dummy Load DA-446/FRT (U) NAVSHIPS0969-098-0010 | Navships | 5/19/05 | Antenna | 1 | ||
| 10-1-11 | Building 2637, Repair Tower Lighting | DON | Antenna | 1 | |||
| 10-1-11b | BLDG 2637 Repair Tower Lighting. Project no. OM 04-113 | DON | 28/.02.06 | 1 | 1 | elect copy only |
| 10-2 | AN/FRT-95A | ||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | |
| 10-2-1 | AN/FRT-95A Transmitter and Antenna Matching Equipment. Local Maintenance Procedures. EE140-NA-PRO-020/FRT-95A. Revision 4. 0913-LP-018-4570. | SPAWAR | Distribution statement: Official use. 4.July 2013 | Antenna | 2 | ||
| 10-2-2 | Radio Transmitting System AN/FRT-95A. Operation and Maintenance Manual with Part List. SPAWAR EE140-NA-OMI-100/FRT-95A. Revision 4. Volume 1 chapters 1-9 | SPAWAR | July 2018 | Antenna | 1 | ||
| 10-2-3 | Technical Manual for Solid State Power Amplifier, Model S11-64M EE140-NA-OMI-090/FRT-95A | SPAWAR | 14.MAY 2008 | Antenna | 2 | ||
| 10-2-4 | AN/FRT-95A NRTF Grindavik Technical Manual and S11-64M Technical Manual. ITEM#: CD08-381. | SPAWAR | 30.nov 2008 | Antenna | 2 CD´s | tech man superseded on this CD. | |
| 10-2-5 | Transmitting Set AN/FRT-95A Transmitter and Antenna Mathcing Subsystem (AMS) Operation and Maintenance - On-The-Job (OJT) Handbook - Instructor Volume | Antenna | |||||
| 10-2-6 | Transmitting Set AN/FRT-95A Transmitter and Antenna Mathcing Subsystem (AMS) Operation and Maintenance - On-The-Job (OJT) Handbook - Student Volume | SPAWAR | Antenna | ||||
| 10-2-9 | Type 11 Output PWB Test Procedures for assemblies 0465200-01,02,03 (Use with Test Fixture TF-11-OC) | Instruments INC | Antenna | 1 | |||
| 10-2-10 | AN/FRT95A NRTF Grindavik Operation and Maintenance Manual volume 1&2 Revision 3 | SPAWAR | 9/15/09 | Antenna | 2 CD´s | ||
| 10-2-11 | Technical Manual. Power Amplifier. Model S11-64F. s/n 03073-03080 | Instruments INC | June 2013 | Antenna | 2 copies | ||
| 10-2-12 | Operation and Maintenance Manual organizational level. Solid State Power Amplifier. Models S11-64F and S11-64G. For the AN/FRT-95A. VLF/LF Radio Transmitting System | SPAWAR | oct 2016 | Antenna | 1 copy | ||
| 10-2-13 | Cooling System for AN/FRT-95A. Installation, Operation and Maintenance Manual. | Des C hamps Labaratories. Inc. | 2 copies | ||||
| 10-2-14 | VFD Manual for Cooling System. AN/FRT-95A. | Des C hamps Labaratories. Inc. | |||||
| 10-2-15 | Installation and Maintenance Manual for P/N: D164-A11-001 120VAC, 50/60 Hz, 1o P7N: D164-a12-001 220VAC, 50/60Hz, 1o Flashing Red Beacon (LED Light) | Dialight Corporation | Sept. 17, 2003 | Doc no. 9600-127-0762-99 Rev C | |||
| 10-2-16 | Instructions for UVIR Flame detector X5200. 95-8546 | Dettronics | 6/29/05 | ||||
| 10-2-17 | Specification Data UVIR Flame Detector X5200. | Dettronics | 6/29/05 | ||||
| 10-2-18 | Specification Data xWatch Explosion-Proof Camera with X-Series Flame Detectors | Dettronics | 6/29/05 |
| 10-3 | AN/FRT Drawings | ||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | |
| 10-3-1 | Grindavik AN/FRT-95A Drawings. Radio Transmitting Systen, AN/FRT-95A Operation and Maintenance Manual, with parts Lists. Revision 4. VOLUME 2 ASSEMBLY DRAWINGS AND SCHEMATICS. EE140-NA-OMI-100/FRT-95A. | SPAWAR | july 2018 | Antenna | 1 | ||
| 10-3-2 | Installation Drawings, VLF/LF Transmitters. 33875. 89-25003. E-size | Antenna | 2 | ||||
| 10-3-3 | Solid State Power Amplifier Models S11-64F and S11-64G Operation and Maintenance Manual, Organizational level with parts lists. Volume 2. S11-64F. Assembly drawings and schematics. | SPAWAR | oct. 2016 | Antenna | 1 | ||
| 10-3-4 | 600ft Tower Drawings | ||||||
| 10-3-5 | Copy of SPAWAR 95A and 72C schematics drawings. Autacad drawings | SPAWAR | 12/14/07 | Antenna | 1 | ||
| 10-3-6 | As Built Wirelist for AN/FRT 95-A Draft copy | SPAWAR | 12/11/12 | Antenna | 1 | Draft | |
| 10-3-7 | As built Drawings. AN/FRT 95-A Draft copy | SPAWAR | 7/4/13 | Antenna | 1 | Draft | |
| 10-4 | 3M | ||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | |
| 10-4-1 | 3M SKED MANUAL & TRAINING | NAVSEA | 7/12/05 | Antenna | CD |
tc={6FD24708-DC98-47C6-BB41-F0AB4A4FED7F}: [Threaded comment]
Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924
Comment:
ATH að við erum líka með þetta óleyfilegt rafrænt sem best er að nota .
Það koma nýjar útgáfur af 3M kerfinu á ca 3mán fresti, þ.a. við erum ekki að merkja CD sérstaklega. CD er geymdur í Admin möppu hjá JL
Series 20-NISBS Equipments / IDNX Circuits
| 20-0 | General Documents | ||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | |
| 20-0-1 | Computer System Operator´s Manual for the STANAG 5030 Formatter (Compatable wiht Software Release 3.10) NTX-CSOM-03-U-R5C0 | SPAWAR | Console room | 1 | |||
| 20-0-2 | Model 6531-KB3 Product Manual, Manual Number: 00431-003-2B | Industrial Computer Source | 1 | ||||
| 20-0-3 | Revised MD-1310/U VLF/LF Modulator, Technical Operations and Maintenance Manual with Illustrated Parts Breakdown | Naval Reserch Labratorys | 1 | ||||
| 20-0-4 | Operation and Maintenance Instructions wiht Parts List - Organizational Maintenance Level, - Compact - Time Integrity Modem, Technical Manual | Naval Reserch Labratorys | 1 | ||||
| 20-0-5 | Operation and Maintenance Instructions wiht Parts List - Organizational Maintenance Level, - Compact - Time Integrity Modem, MD-1315/UGC and MD-1316/UGC Technical Manual | NISE | 1 | ||||
| 20-0-6 | Tuning Pattern Generator, Instruction Manual | Naval Reserch Labratorys | 1 | ||||
| 20-0-7 | Standard Operating Procedures (SOP) for the AN/BSQ-9(V)3 Time and Frequency Dirstribution System (TFDS) and the HNV-560C, Radio Receiver Precision Lightweight GPS Receiver (PLGR) | SPAWAR | Console room | 2 | |||
| 20-0-8 | TFDS _V(3) Shore Manual EE170-EK-MMA-010 | Brandywine c ommunications | 1/1/01 | 1 | |||
| 20-0-9 | User Guide - Fortress.TeleCom 750VA, 1050 VA, 1425 VA, 1800 VA, 2250 VA - UPS | ||||||
| 20-0-10 | Power Options, Product Manual, 00431-240-2A | Industrial Computer Source | 2 | ||||
| 20-0-11 | 7408 and 7415 Series Product Manual, 00431-085-22C | Industrial Computer Source | 2 | ||||
| 20-0-12 | ISA/PCI BACKPLANES, Product Manual, 00431-020-4C | Industrial Computer Source | 3 | ||||
| 20-0-13 | SBT586T Product Manual | Industrial Computer Source | 2 | ||||
| 20-0-14 | Video Driver Disks CL-GD5446 | Industrial Computer Source | 1 | ||||
| 20-0-15 | STU-III Secure Voice/Data Terminal Model 1100 Single-Line, Model 1150 Multi Line, Users Manual 0N-493106 | AT&T | 1 | ||||
| 20-0-16 | RS-232/V.24 and V.35 PatchSwitch User Manual ADCP-50-304 | ADC | 1 | ||||
| 20-0-17 | Patchmate RS-232/V.24 and V.35 Digital Patching User Manual ADCP-50-305 | ADC | 1 | ||||
| 20-0-18 | Powerware Profile 8kVA-12,3kVA Operator´s Manual | Powerware | 1 | ||||
| 20-0-19 | Powerware 9150 User´s Guide 8 kVA - 12.5 kVAP | Powerware | 1 | ||||
| 20-0-20 | Powerware Setup Disk (Software CD) 05146745 REV.A | Powerware | 1 | ||||
| 20-0-21 | Technical Manual for FSK Modem, Radio Teletype, 1280 R C-51-552-000/MS-001 | Plantronics | Radio Teletype | 1 | |||
| 20-0-22 | Technical Manual Base ARC Detector Subsystem | Pacific-Sierra Research Corporatiion | 2 | ||||
| 20-0-23 | Fiber Obtic Upgrade | Siminn | 5/28/13 | Drwgs | Electr copy only | ||
| 20-0-24 | Training Video for NISBS Equipment | 12/15/14 | VidepCD | CD |
| 20-1 | NISBS Equipments | |||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | ||
| 20-1-1 | Operating Procedures fot the Nato Interoperable Submarine Broadcast System (NISBS) Formatter atn tne Broadcast Site (BTS) NTX-OP-U-R0C0 | SPAWAR | Console room | 4 | ||||
| 20-1-2 | System Operational and Verification TEST (SOVT) for the Nato Interoperable Submarine Broadcast System (NISBS) - NTX-SOVT-01-R1C0 , 31 JULY 2001 | SPAWAR | 2 | |||||
| 20-1-3 | System Operational and Verification TEST (SOVT) for the Nato Interoperable Submarine Broadcast System (NISBS) - NRaD-831JM-6220 | NRaD | 9/1/96 | 1 | ||||
| 20-1-4 | Nato Internoperable Submarine Broadcast System (NISBS) Installation Design Plan for Naval Radio Transmitter Facility (NRTF) Grindavik Iceland, Final 5/29/98 | 1 | ||||||
| 20-1-5a | MS-DOS-6.22 for transmitters | software | 1 cd | software | ||||
| 20-1-5b | NTX-VDD-16-U-R0C0. NTX Release 3.10. Master 1 of 1. | SPAWAR | 1/13/00 | CD - | 1 cd | software | ||
| 20-1-6a | Power Station, Operations and Maintenance Manual. ETI0015-2203AD | |||||||
| 1000 VA with Extended Battery Time ETI Document No. ETIMA15-2203AD | Energy Technologies, Inc | May 4, 2007 | 1 | 1 electr. Copy | ||||
| 20-1-6b | Installation and operation. Smart-UPS. Surta 1500XL/1500RMXL2U/1500XLJ | APC by Schneider | 7/1/09 | 1 | ||||
| 20-1-6c | Supplier part for Surta 1500XL/1500RMXL2U/1500XLJ (cd and bag with supplies) | APC by Schneider | 7/1/09 | CD - | 1 | |||
| 20-1-7 | P/N: ETI0015-2203AD. PersonalSource Rugged COTS 1000VA Rackmount UPS with Extended Battery Time. | Energy Technologies, Inc | 1 | |||||
| 20-1-8 | Power Station. Information & User Manual Access. ETI0015-2203AD 1000VA with Extended Battery Time | Energy Technologies, Inc | May 4, 2007 | 1 | ||||
| 20-1-9a | Nato Interoperable Submarine Broadcast System (NISBS) Suite NO.2 Installation Design Plan for NRTF Grindavik Iceland. | Engility | 04/13/2015 | 1 | ||||
| 20-1-9b | Nato Internoperable Submarine Broadcast System (NISBS) NO.2 Installation Design Plan (IDP) for NRTF Grindavik Iceland. | Engility | 04/13/2015 | 1 | ||||
| 20-1-10 | BTS System Groom List - NISBS Formatter, System 1 | 06/24/2013 | 1 | |||||
| 20-1-11 | BTS System Groom List - NISBS Formatter, System 2 | 06/24/2013 | 1 | |||||
| 20-1-12 | BTS System Groom List - NISBS Formatter, System 1 | 03/10/15 | 1 | |||||
| 20-1-13 | BTS System Groom List - NISBS Formatter, System 2 | 03/10/15 | 1 |
| 20-2 | IDNX Circuits | ||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | |
| 20-2-1 | IDNX, Integrated Digital Network Exchange, Manuals 1 | Network Equipment Technology | 1 | ||||
| 20-2-2 | IDNX, Integrated Digital Network Exchange, Manuals 2 | Network Equipment Technology | 1 | ||||
| 20-2-3 | NISBS Single Flow Circuit Diagrams | may 2011 | shown in ppt | electr copy | |||
| 20-2-4 | IDNX Data Modules. Release 3.x7. Promina Series, Multiservice Access Platform | Network Equipment Technology | 6/28/05 | IDNX | Elect copy | electr copy | |
| 20-2-5 | Eaton 9130 UPS 700VA to 3 kVA Quick Start | Eaton | 1/12/16 | IDNX | 2 elec copy also |
| 20-3 | IDNX Drawings | ||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | |
| 20-3-1 | HFTX Frankfurt Bracknell Skemi. - Skemateikning af sérlínum Bracknell og Frankfurt. Milli Nato H | Mila | 9/13/13 | IDNX | Electr. |
| 20-4 | LBUCKS Equipments | ||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | |
| 20-4-1 | LBUCKS Training | 2/1/20 | LBUCKS | several documents |
tc={637D7A66-F2BF-4555-8397-EED3F9B30311}: [Threaded comment]
Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924
Comment:
margskonar skjöl eru í einum folder merktur 20-4-1. það þarf bara að rúlla í gegnum þetta og finna hvað best er að nota hverju sinni
| 20-4-2 | BTS USM (Broadvast Terminal System) All Manuals and other instructions | LBUCKS | Folder | All doc are on 72 Thin Client desktop | ||
| 20-4-4 | CommSync II. Model 385 Redundant GPS Synchronized Time and Frequency System User´s Manual. Document 385-8000. Rev AJ | FEI-Zyfer Inc | 2015 | LBUCKS | 1 | Manual is on 72 Thin Client desktop |
| 20-4-5 | HP8562A/B High Performance Portable Spectrum Analyzer. Operating and Programming Manual. | Hewlett-Packard | 1987 | LBUCKS | 1 | |
| 20-4-6 | Quick Guide. Power Value !1 RT G2. | ABB | 5/20/20 | LBUCKS | 1 | and USB drive |
| Series 30 - Test Equipments | |||||||
| 30-0 | General Documents | ||||||
| Number | Title & other information | Vendor | Date of issue | Category | Quant. | Remarks | |
| 30-0-1 | HP 5334B Universal Counter, Performance Tests, Adjustments, Replaceable Parts, Manual Change, Service | HP | Test Equipment | 1 | |||
| 30-0-2 | HP 5334A HP5334B, Operationg and Programming Manual, Universal Counter, Performance Tests, Adjustments, Replaceable Parts, Manual Change, Service | 1 | |||||
| 30-0-3 | 8840A Digital Multimeter, Instruction Manual | Fluke | Test Equipment | 1 | |||
| 30-0-4 | Service Manual, Interference/Field Strength Meter ML428N | Anritsu Corp | Test Equipment | 1 | |||
| 30-0-5 | Operating and Service Manual Model HP 3575A. Gain-Phase Meter | HP | March 1990 | Test Equipment | 1 | ||
| 30-0-6 | Fluke 77/75/23/21 Series III Multimeter Instruction sheet | Fluke | 2 copies | Test Equipment | 1 | ||
| 30-0-7 | Transmission Test Set 3551A | HP | Test Equipment | 1 | |||
| 30-0-8 | Instruction Manual Megohmmeter Model R1M-A. S/N 21801 thru 21975 | PPM inc. | 9/19/91 | Test Equipment | 1 | ||
| 30-0-9 | Signal Genrator 8640B - Operating Information | HP | Test Equipment | 1 | |||
| 30-0-10 | Agilent 34401A 6 1/2 Digit Multimeter. Product Reference CD-ROM vers. 1.2 | Agilent Technologies | CD ROM | Test Eqipment | 1 | CD ROM with manual and software | |
| 30-0-11 | HP 3324A Synthesized Function/Sweep Generator, Operating and Programming Manual | HP | Test Equipment | 1 | |||
| 30-0-12 | ANRITSU MG3641NV Synthesized Signal Generator | Anritsu Corp | Test Equipment | 1 | |||
| 30-0-13 | Technical Manual Operation and Maintenance instructions with parts list RECEIVER R-2368/URR | Harris RF-Communication | May 1989 | Receiver | 1 | ||
| 30-0-14 | Hipotronics 860PL. Portable DC insulation tester. | Protec Inc | Test Equipment | 1 | |||
| 30-0-15 | Instruction Book for Amplifier, AF AM-413/G, AM-413A/G and Dynamic Loudspeaker LS169/G | Hamon-Kardon | 1 | ||||
| 30-0-16 | Selective Level Meter 3586A/B/C, Service Manual, Volume II | HP | Test Equipment | 1 | |||
| 30-0-17 | Model 5500 A BIT ERROR RATE TESTER | Phoenix | Test Equipment | 1 | |||
| 30-0-18 | HP 4284A Precisioin LCR Meter, Operation Manual | HP | Test Equipment | 1 | |||
| 30-0-19 | Model 6039A/AZ Frequency Synthesizer, Instruction Manual | Fluke | Test Equipment | 1 | |||
| 30-0-20 | Model 145, 145-S-620, 145-S-872 and 145-S-1021, 20 MHz Pulse/Function Generator | Wavetek | Test Equipment | 1 | |||
| 30-0-21 | 45 Dual Display Multimeter - Users Manual | Fluke | Test Equipment | 1 | |||
| 30-0-22 | HP 34401A Multimeter, User´s Guide, ESI 16415 | HP | Test Equipment | 1 | |||
| 30-0-23 | Ship / Shore Portable Electrical / Electronic Test Equipment Requirments List (SPETERL)NAVRADTRANSFAC GRINDAVIK | Naval Warefare Assesment Division | Test Equipment | 1 | |||
| 30-0-24 | Test Equipment Administration and Use | Naval Warefare Assesment Division | Test Equipment | 1 | |||
| 30-0-25 | Frequency-Time Standard AN/URQ-23 Part NO. 11500-2800, Technical Manual Operation and Maintenance Instructions with Parts List Organization Maintenance Level | Frequency Electronics INC | Test Equipment | 1 | |||
| 30-0-26 | Mesurement Computation System, 760A Fluke | HP | Test Equipment | 1 | |||
| 30-0-27 | Loop Array Test System for the use with TCI end Fire Loop Array Series 612-8 | TCI | Test Equipment | 1 | |||
| 30-0-28 | Probes Models 10001, 2, 3 | HP | Test Equipment | 1 | |||
| 30-0-28 | Probes Models 11044A/11045A DC Divider | HP | Test Equipment | 1 | |||
| 30-0-28 | Probes P6006, P6007, P6028, P6062B, P6101, P6106 | HP / Tektronic | Test Equipment | 1 | |||
| 30-0-28 | Lab Cart, Model 3 | Tektronix | Test Equipment | 1 | |||
| 30-0-28 | Webbing Stap with Buckle | Tektronix | Test Equipment | 1 | |||
| 30-0-28 | 205 Scope-Mobile | Tektronix | Test Equipment | 1 | |||
| 30-0-29 | Fluke Multimeters 80 Series III | Fluke | Test Equipment | 1 | 2 cd´s also | ||
| 30-0-30 | Shore Test Equipment Index - Shore Test Equipment Allowance Program (STEAP) - NAVELEX P4734-5 MAR 1984 | NESEA | Test Equipment / standard | 1 | |||
| 30-0-31 | Model 4200-S/21 RF Microwattmeter Serial numbers 975 and abobe - Instructions Manual | Boonton | Test Equipment | 1 | |||
| 30-0-32 | Equipment Indentification Code Master Index (EIC) | DON | standar / index | 1 | |||
| 30-0-33 | Portable Electrical/Electronic Test Equipment /PEETE) Index for support requirements of ship/shore electronic, electrical, ic, weapons, and porpulsion system | DON | standar / index | 1 | |||
| 30-0-34 | Portable Electrical/Electronic Test Equipment /PEETE) Index for support requirements of ship/shore electronic, electrical, ic, weapons, and porpulsion system | 1 | |||||
| 30-0-35 | Model 3440A/3442A RF Millivoltmeter - Ballantine | Ballantine | 1 | ||||
| 30-0-36 | 323 Series True RMS Voltmeters | Ballantine | 1 | ||||
| 30-0-37 | Model 175-AV Autoranging Multimeter Isnstruction Manual, Contains Operating and Servicing Information, 175-AV-901-01 Rev.A | Keithley Instruments | Test Equipment | 1 | |||
| 30-0-38 | 492/492P Spectrum Analyzer, Service V olume 2 Instruction Manual | Tektronix | Jul 1079 | Test Equipment | 1 | ||
| 30-0-39 | RF Termination Dact-153 Model C12567 | Electro Impulse inc. | Test Equipment | 1 | |||
| 30-0-40 | Technical Manual for Models 6730E and 6732E Coaxial Transfer Switch | Delta Electronics | 9/1/85 | Equipment | 1 | ||
| 30-0-41 | HF8090 Radio Set Control (622-3390-006) intermediate Maintenance | Rockwell International | Jun 1987 | Test Equipment | 1 | ||
| 30-0-42 | HF-8151A Radio Frequency Transmitter, Intermediate Maintenance | Rockwell International | Jun 1987 | Transmitter | 1 | ||
| 30-0-43 | 495P Spectrum Analyzer, Service Manual, Volume 1 | Tektronix | Test Equipment | 1 | |||
| 30-0-44 | 495P Spectrum Analyzer, Service Manual, Volume 2 | Tektronix | Test Equipment | 1 | |||
| 30-0-45 | HP 8562A/B High Performance Portable Spectrum Analyzer, Installation Manual | HP | Test Equipment | 1 | |||
| 30-0-46 | 492/492P Spectrum Analyzer Operators Instruction Manual | Tektronix | Test Equipment | 1 | |||
| 30-0-47 | 492/492P Spectrum Analyzer, Portable/Rackmount/Benchtop, Service Volume 1, Instruction Manual | Tektronix | Test Equipment | 1 | |||
| 30-0-48 | 495/495P Spectrum Analyzer, SN B020100 and up | Tektronix | Test Equipment | 1 | |||
| 30-0-49 | Model 5200-17 Universal Transmission Analyzer - Operation and Maintenance Manual | CXR Telcom | Test Equipment | 1 | |||
| 30-0-50 | 492/492P Spectrum Analyzer Portable/Rackmount/Benchtop (SN B029999 & Below), Service Volume 2 Instruction Manual | Tektronix | 1 | ||||
| 30-0-51 | 492/492P Spectrum Analyzer Portable/Rackmount/Benchtop (SN B029999 & Below), Service Volume I Instruction Manual | Tektronix | 1 | ||||
| 30-0-52 | MIQ Program (Measure Interactive Query Program) ver. 1.0.2.1. Navy Metrology/Calibration Program | Measure Operational Control Center, Norfolk VA | CD | 1 | |||
| 30-0-53 | Power Platform 4300. TASKCard PQLite. Users Guide | Dranetz BMI | May 1, 2002 | Test Equipment | 1 | ||
| 30-0-54 | DRAN-Link 4300 Operator´s Manual | Dranetz BMI | March 15,1996 | Test Equipment | 1 | ||
| 30-0-55 | Power Platform 4300. TASKCard PQLite. Training kit. | Power CET | Test Equipment/ training Kit | 1 | |||
| 30-0-56 | Operating and Service Manual Model 3400A RMS Voltmeter | Hewlett Packard | 1.december 1986 | 1 | |||
| 30-0-57 | Instruction Manual 8000A Digital Multimeter | Fluke | may 1979 | 1 | |||
| 30-0-58 | Instruction Manual for Microohmmeter and Bond Tester Model R1L-B | Tegam | dec 2012 | 1 | |||
| 30-0-59 | Instructions fro Battery Drop Tester 6/12V Model no. BT91/7.V3 | Sealey | 2/29/16 | 1 |
| 30-1 | Oscilloscopes | ||||||
| Number | Title & other information | Vendor | Date of issue | Category | Quant. | Remarks | |
| 30-1-1 | TDS 420A, TDS 430A, TDS 460A & TDS 510A Digitizing Oscilloscopes 070-9701-00 | Tektronix | Test Equipment | 1 | |||
| 30-1-2 | 2213 Oscilloscope Service, Instruction Manual | Tektronix | Aug 1982 | Test Equipment | 1 | ||
| 30-1-3 | 2336YA Oscilloscope Service, Instruction Manual | Tektronix | Oct 1983 | Test Equipment | 1 | ||
| 30-1-4 | 2246 1Y, 2R and 2246 MOD A Portable Oscilloscope Service - SN B700100 and Above (2246 1Y,2R) SN B100100 and Above (2246 MOD A) | Tektronix | Test Equipment | 1 |
| 30-2 | Test Equipment Manuals in PDF format | ||||||
| Number | Title & other information | Vendor | Date of issue | Category | Quant. | Remarks | |
| 30-2-1 | Agilent HP 435B Power Meter | Agilent Technologies | Test Equipment | 1 | |||
| 30-2-2 | Agilent HP 3325A Synthesizer/Function Generator | Agilent Technologies | Test Equipment | 1 | |||
| 30-2-3 | Agilent HP 3400A RMS Voltmeter | Agilent Technologies | Test Equipment | 1 | |||
| 30-2-4 | Agilent HP 3575A Gain-Phase Meter | Agilent Technologies | Test Equipment | 1 | |||
| 30-2-5 | Agilent HP 8904A Multifunction Synthesizer | Agilent Technologies | Test Equipment | 1 | |||
| 30-2-6 | Agilent HP 34401A 6 1/2 Digit Multimeter | Agilent Technologies | Test Equipment | 1 | |||
| 30-2-7 | Agilent HP 8481A & 8482A Power Sensor | Agilent Technologies | Test Equipment | 1 | |||
| 30-2-8 | Agilent HP 84811A Peak Power Sensor | Agilent Technologies | Test Equipment | 1 | |||
| 30-2-9 | Biddle Megger 212159 Series | AVO International | Test Equipment | 1 | |||
| 30-2-10 | ESI 250da Resistance Bridge | Electro Sicentific Industries | Test Equipment | 1 | |||
| 30-2-11 | Fluke 6060A/AN Synthesized RF Signal Generator | Fluke | Test Equipment | 1 | |||
| 30-2-12 | Fluke 8000A Digital Multimeter | Fluke | Test Equipment | 1 | |||
| 30-2-13 | Fluke 8840A Digital Multimeter | Fluke | Test Equipment | 1 | |||
| 30-2-14 | Hi-Pot 860PL Portable DC insulation tester | Hipotronics | Test Equipment | 1 | |||
| 30-2-15 | Keithley 175-AV Autoranging Multimeter | Keithley Instruments | Test Equipment | 1 | |||
| 30-2-16 | Fluke VT04 Visual IR Thermometer | Fluke corp | Test Equipment | 1 | |||
| 30-2-17 | Tegam R1L-B MicroOhm Metera and Bond Tester | Tegam | Test Equipment | 1 | |||
| 30-2-18 | Tektronix TDS3000 Series Digital Phosphor Oscilloscopes 071-0274-01 | Tektronix | Test Equipment | 1 |
| 30-3 | Ground Tester Workbook | ||||||
| Number | Title & other information | Vendor | Date of issue | Category | Quant. | Remarks | |
| 30-3-0 | Ground Tester Workbook | AEMC Instruments | Test Equipment |
| Series 40- Facility | |||||||
| 40-0 | General Documents | ||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | |
| 40-0-1 | User Manual Gate with drive HMDLP230, HGD230 | Heras | 20220401 | Main Gate | 1 | elec copy only | |
| 40-0-2 | Model WPP-331-D With ATD-11 Weatherproof Telephone and Model SSP-311-D With ATD-11 Stainless Steel Panel Telephone, Service Manual | CEECO | phone by gate | 1 | |||
| 40-0-3 | HERAS User Manual. Gate with drive. HMDLP230 HGD230 | Heras NL | Main Gate | 1 | |||
| 40-0-4 | Operation Manual for Router. Double Insulated Model No.315.269210 | Craftsman | 1 | ||||
| 40-0-5 | User Manual Manual Sliding Gates, DELTA-UGATE-AXEL | Heras | 20220419 | Main Gate | elec copy only | ||
| 40-0-6 | Portable Personnel Lifts UL II-25/32/40. Service & Parts Manual, Serial numbers 16600 to current. | Upright Europe | 1 | ||||
| 40-0-7 | Instruction Manual Dewalt DW734 12-1/2 Heavy Duty Portable Thickness Planer. | Dewalt | 1 | ||||
| 40-0-8 | Weed Eater. Instruction Manual | 1 | |||||
| 40-0-9 | Owners Manual. Permanently Lubricated Single Stage Portable Air Compressor. Model no 919-167312 | 1 | elec copy | ||||
| 40-0-10 | Operation and Maintenance Manual. Model 0200 OMD. SemShred | SEM | 14.may 2020 | Office | 1 | ||
| 40-0-11 | Motorola Solutions Talk Radio | Motorola | 6/1/23 | Office | 1 | ||
| 40-0-12 | Operating & Maintenance Manual for MTD (Mover) | MTD Products | 1 | ||||
| 40-0-13 | Trailer Mounted Work Platform TL-49. Service & Parts Manual. | Upright Europe | 1 | ||||
| 40-0-14 | Tanaka Owners Manual (Gras Cutter) TBC 4000/4001. TBC 4500/4501 | Tanaka | 1 | ||||
| 40-0-15 | Snow Plow System E-58H | Meyer-electro-Lift | 1 | ||||
| 40-0-16 | Yanmar Diesel engine LA series. Operation Manual | Yanmar Diesel engine co.ltd. | 1 | ||||
| 40-0-17 | Torrivents and Cabinet fans. Installation Maintenance TORR-IM-2D. Feb 86 | Trane | 1 | ||||
| 40-0-18 | Modular Cl imate changer. Central Station air Handlers. Installation Manual. CLCH-IM-I3 | 1 | |||||
| 40-0-19 | Central Station Air Handlers climate changer. Unit Parts CLCH-UP-21A | 1 | |||||
| 40-0-20 | HOBO & Tattletale Data Loggers/ controllers. Indoor, Outdoor, Underwater and OEM Products | onset (www.onsetcomp.com) | 1 | Book | |||
| 40-0-21 | HOBOware Pro. Software fro HOBO Data Loggers & Devices. Version 2.x for windows | onset (www.onsetcomp.com) | 1 CD | CD + manual | |||
| 40-0-22 | Instruction leaflet for 3 Tonne heavy duty trolley jack | Draper - the tool company | 8/1/01 | ||||
| 40-0-23 | Lifepack 500 Automated Exernal Defibrillator Setup Instructions | Medtonic Physio-Control | oct. 2001 | ||||
| 40-0-24 | Installation & Maintenance Instructions for A-L810 Austin LED Steady-Burning Red Obstruction Light | Austin Insulators Inc. | March 24, 2006 | 1 | |||
| 40-0-25 | HF-251D-1 and HF-251-2 Owners Manual | Millerwelds.com | |||||
| 40-0-26 | Brother P-Touch 2600/2610 User´s Guide & Brother P-Touch XL | Brother | 1 | ||||
| 40-0-27 | Air Conditioner- Outdoor Unit. Installation Manual | ||||||
| 40-0-28 | Air Conditioner- Wall Mounted Type. Installation Manual | ||||||
| 40-0-29 | Air Conditioner- Wall Mounted Type. Operating Manual | 1cd | Transformer house | ||||
| 40-0-30 | Operation and Maintenance Manuals - HVAC System. Repairs to Transmitter Cooling. | Lunseth | 9/1/09 | 1 | 1 cd | ||
| 40-0-31 | Military Handbook. MIL-HDBK-419A. Grounding, bonding and shielding for electronic equipments and facilities. Volume 1 & 2 | Department of Defense | 29.dec 1987 | 1 | |||
| 40-0-32 | Installation & Maintenance Manual for Unit Heaters (hitablásari í Drama) | 1 | |||||
| 40-0-33 | Owners Manual. Craftsman 600Watt AC Generator. | Craftsman | 08/28/2000 | 1 | |||
| 40-0-34 | Military Handbook MIL-STD-188-124B Grounding, Bonding and shielding | Department of Defense | 2/1/92 | 1 | + elec copy | ||
| 40-0-35 | Gate Camera | elec copy only | |||||
| 40-0-36 | Operator´s Manual Two-Stage Snow Thrower | MTD Products | 9/7/04 | ||||
| 40-0-37 | Techumseh Operators Manual and Maintenance instrucion. Models HSK35,40,HSSK50 | Techumseh products | 6/26/05 | ||||
| 40-0-38 | SEM Shredder Model 344 and 2026-3. Operation and Maintenance Manual | SEM | 30.may 2019 | Library | Elec copy | ||
| 40-0-39 | NUC244NX Compact Scrubber Dryer | Numatic | 6/1/21 | Library | |||
| 40-0-40 | Weller WE1, WEP70, PH70 | Weller tools | 2021 | Library | |||
| 40-0-41 | NX300 Numatic Charger | Numatic | 2020 | Library | |||
| 40-0-42 | KRAMER 8085T English version - Manual Þýskur á bókasafni | Kramer | 2021 | Library | Elec copy English | ||
| 40-0-43 | Threat Extracted Manual Vikplog - For Kramer | AB Siringe Teknik | 2021 | Library | Elec Copy |
| 40-1 | Dehydrator | ||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | |
| 40-1-1 | VSA Series Air Dryer. Users Guide | Puregas | Dehydrator | 1 | |||
| 40-1-2 | Deleted | ||||||
| 40-1-3 | Deleted | ||||||
| 40-1-4 | Deleted | ||||||
| 40-1-5 | Water Ring Rotary Air Compressors DC series | Dielectirc Communicatiions | Dehydrator | 1 | |||
| 40-1-6 | Single/Two Stage Belt Driven Compressor. Instruction Manual | Fima | Dehydrator | 1 | |||
| 40-1-7 | Deleted | ||||||
| 40-1-8 | Deleted | ||||||
| 40-1-9 | Deleted | ||||||
| 40-1-10 | Baldor Motor Installation & Operation Manual. AC Induction Motors | Baldor | 1 | ||||
| 40-1-11 | P4200W Series Air Dryer User's Guide | Puregas | Dehydrator | 2 | + elec copy |
| 40-2 | Generator & Power System | ||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | |
| 40-2-1 | Low Voltage Switchgear O & M Manual - Part 1 of 2 | Schneider Electric | August 15, 2016 | Generator | 3 | 1 in Diesel. + Elec cpy | |
| 40-2-2 | Low Voltage Switchgear O & M Manual - Part 2 of 2 | Schneider Electric | August 15, 2016 | Generator | 3 | 1 in Diesel. + Elec cpy | |
| 40-2-3 | Panelboards O & M Manual - Part 1 of 1 | Schneider Electric | August 15, 2016 | Generator | 3 | 1 in Diesel. + Elec cpy | |
| 40-2-4 | Cummins Power System, Submittal Data & Bill Material | Cummins | Generator | 3 | 1 in Diesel | ||
| 40-2-4 | Generator Set Installation Manual | Cummins | 05-2015 Issue4 | Generator | 3 | 1 in Diesel | |
| 40-2-4 | Generator Set Operator Manual | Cummins | 05-2015 Issue3 | Generator | 3 | 1 in Diesel | |
| 40-2-4 | Generator Set Parts Manual | Cummins | 06-2016 Issue8 | Generator | 3 | 1 in Diesel | |
| 40-2-4 | Generator Set Service Manual | Cummins | 02-2015 Issue4 | Generator | 3 | 1 in Diesel | |
| 40-2-4 | HC Alternators, Installation. Service, and Maintenance Manual | Stamford/Cummins | 2016 Issue1 | Generator | 3 | 1 in Diesel | |
| 40-2-4 | Cummins Recommended Spare Parts. W.pricing | Cummins | 7/8/05 | Generator | 3 | 1 in Diesel | |
| 40-2-5 | O & M Manual - QST30 Series Engine | Cummins | February 2016 | Generator | 3 | 1 in Diesel | |
| 40-2-6 | K875A Load Bank, User Manual | Avtron | 6/1/16 | Generator | 3 | 1 in Diesel | |
| 40-2-7 | Battery Charger. Owners Manual Operator/Installation. | Cummins | 01-2016 Issue2 | Generator | 2 | 1 in Diesel. CD in Man | |
| 40-2-8 | Cummins Owners Packet (the black bags) | Cummins | 7/8/05 | Generator | 2 | 1 in Diesel | |
| 40-2-9 | IOM Manual. Remote Intercoolers and Engine-Driven RhinoDrive Radiators | ThermaSys | 10/1/12 | Generator | 2 | ||
| 40-2-10 | TLS4/8601 Series Console. Tank Level Console | Veeder-Root | 2016 RevD | Generator | 1 | ||
| 40-2-11 | O & M Manual. MTC-500/1000/3000 Mobile Tank Cleaning System | Algae-x | 2006 RevC | Generator | 1 | + elec copy | |
| 40-2-12 | Electrical Digital Meter for Fuel.(Computer & Housing) Owners Manual | John C. Ernst Co. | 2010 | Generator | 1 | ||
| 40-2-13 | FieldTest Procedure for Modified Differential Ground Fault Protection Systems | Square D Company | 6/27/05 | Generator | 1 | ||
| 40-2-14 | Instruction Bulletin. NTMPRRT/NWMPRRT- Masterpact NT and NW Remote Racking Devices | Schneider Electric | 7/2/05 | Generator | 1 | ||
| 40-2-15 | BE1-700 Digital Protective Relay | Basler Electric | july 2014 | Generator | 2 | ||
| 40-2-16 | Power Safe Lead Acid Stationary Batteries. Product Warranty and Operating Instructions & Power Safe EC-M Battery Performance Specifications | EnerSys | 1.1.2014 & Aug 2016 | Generator | 1 | & Elec copy | |
| 40-2-17 | MSG Paralleling Switchgear Auto throw-over Manual. Operations and Maintenance Manual | Schneider Electric | Sept 2016 | Generator | 1 | ||
| 40-2-18 | Power Safe data safe. Safety, storage, installation, operation & maintenance manual. Flooded Lead-Acid batteries, C,D,E,F and G | EnerSys | 9/1/16 | Generator | 1 | & Elec copy |
| 40-3 | Facility Drawings | ||||||
| Number | Title & other information | Vendor | Date of issue | Categ. | Quant. | Remarks | |
| 40-3-1 | Index of Hardcopy Facility Drawings | ||||||
| 40-3-2 | Index of Hardcopy Power Drawings | ||||||
| 40-3-3 | Folder for various facility Drawings on electronic format | ||||||
| 40-3-4 | Power Distribution Drawings for Flugfjarskipti | AFL Engineering | 8/8/07 | Fac/flugfj | 1 | Drwngs from Flugfjarskipti. Drawer #4 | |
| 40-3-5 | Switchgear and Generator Replacement (N62583-12-D-0762-0029) | FDC | 04/18/2017 | Facility | 2 | 1 in Diesel + Elec cpy. Drawer #1 | |
| 40-3-6 | Transformers and Electrical Repairs | FDC | 12/11/14 | Facility | 2 | Also elec copy. Drawer #1 | |
| 40-3-7 | Dry Air Supply Distribution, AN/FRT-95A / AN/FRT-72C | HiQ | 7/2/18 | Dehydrator | 1 | Drawings |
| 40-4 | Software Licenses | |||||
| 40-4-1 | Software License Certificate for S-OP11CS/W (símstöð) | 8/13/02 | Símstöð | 1 | Leyfisbréf |
| 40-5 | Fire System | |||||
| 40-5-1 | 2451 & 2451TH Photoelectronic Plug-In Smoke Detectors | simplex | 6/26/05 | fire system | Electronic copy only | |
| 40-5-2 | 4098 Detectors Sensors and Bases. Application Manual | simplex | 6/30/05 | fire system | electronic copy only | |
| 40-5-3 | 4002 Fire Alarm. Programming Instructions. Rev. 1.09 | simplex | fire system | Electronic copy only |
| Series 50- Reports, Requirements & Instructions | |||||||
| 50-0 | Reports | ||||||
| Number | Title & other info | Vendor | date of issue | Categ. | Quant. | Remarks | |
| 50-0-1 | PWM Antennas, 13 week report Antennas | 1 | |||||
| 50-0-2 | Tower Inspection 600F 2005 | Tower Inspection Inc. | 1 | ||||
| 50-0-3 | Tower Inspection 1000F 2005 | Tower Inspection Inc. | 1 | ||||
| 50-0-4 | Inspection Report FY01 600" Guyed Tower no. 2637, Grindavik Iceland | Tower Inspection Inc. | 1 | ||||
| 50-0-5 | Inspection Report FY95 Vibration Damper Inspection 1000" Guyed Tower Grindavik Iceland | Tower Inspection Inc. | 1 | ||||
| 50-0-6 | Inspection Report FY95 600" Guyed Tower No.2635 Grindavik Iceland | Tower Inspection Inc. | 1 | ||||
| 50-0-7 | Antenna Tower Inspections Report for 1000" (305m) Tower, conducted 1994 | Tower Inspection Inc. | 1 | ||||
| 50-0-8 | Inspection Report FY93 600" Guyed Tower no. 2637, Grindavik Iceland | Tower Inspection Inc. | 1 | ||||
| 50-0-9 | Inspection Report FY91 600" Guyed Tower no. 2637, Grindavik Iceland | Tower Inspection Inc. | 1 | ||||
| 50-0-10 | Inspection Report FY89 600" Guyed Tower no. 2637, Grindavik Iceland | Tower Inspection Inc. | 1 | ||||
| 50-0-11 | Inspection Report FY87 600" guyed Tower no. 2637, Grindavik Iceland | Tower Inspection Inc. | 1 | ||||
| 50-0-12 | Inspection Report FY85 600" guyed Tower no. 2637, Grindavik Iceland | Tower Inspection Inc. | 1 | ||||
| 50-0-13 | Radhaz Survey Report november 2004 | Spwar, Charelston s-Carolina | november 2004 | Report, security | 1 | ||
| 50-0-14 | Radhaz Survey Report january 2004 | Spwar, Charelston s-Carolina | january 2004 | Report, security | 1 | ||
| 50-0-15 | Radhaz Survey Report march 2002 | Spwar, Charelston s-Carolina | March 2002 | Report, security | 1 | ||
| 50-0-16 | Radhaz Survey Report June 1996 | Spwar, Charelston s-Carolina | June 1996 | Report, security | 1 | ||
| 50-0-17 | Tower Inspection Report 1000´Guyed LF Tower, Grindavik Iceland | Tower Inspection Inc. | March 2001 | Report, security | 1 | ||
| 50-0-18 | Radhaz Survey Report Sept 2008 final report for the NRTF Grindavik Iceland | Spwar, Charelston s-Carolina | 9/1/08 | Report, security | 1 | ||
| 50-0-19 | Tower Inspection Report 600' Guyed LF Antenna no. 2637, Grindavik Iceland | SPAWAR | march 2008 | Report, security | 1 | ||
| 50-0-20 | Tower Inspection Report 1000' Guyed LF Antenna no. 2636, Grindavik Iceland | SPAWAR | march 2008 | Report, security | 1 | ||
| 50-0-21 | Critical Power Equipment Assessment NRTF Iceland. Site Specific Report. SSR-NAVFAC-EXWC-PW-1302 | NAVFAC | April 2012 | Site specific Report | 1 | elect copy | |
| 50-0-22 | Radhaz Survey Report August 2013 | NAVFAC | August 2013 | Report, security | 1 | elect copy | |
| 50-0-23 | 20080321 Grindavik Trip Report. Trip Report NCTAMS LANT Det Iceland | SPAWAR | 2/21/08 | Trip report / report security | 1 | elect copy | |
| 50-0-24 | FSBS.ANT.TRIP.NRK-20090914. Trip Report NCTAMS LANT Det Iceland | SPAWAR | 9/14/09 | Trip report / report security | 1 | elect copy | |
| 50-0-25 | FSBS.ANT.TRIP.NRK-20100628. Trip Report NCTAMS LANT Det Iceland | SPAWAR | 28.JUNE 2010 | Trip report / report security | 1 | elect copy | |
| 50-0-26 | FSBS.ANT-TRIP.NRK-20131121. Trip Report NCTAMS LANT Det Iceland | SPAWAR | 2/21/13 | Trip report / report security | 1 | elect copy | |
| 50-0-27 | NAVFAC EXWC TRIP REPORT. NRTF GRINDAVIK ICELAND. 7.-11.JULY 2014 | SPAWAR | 14.JULY 2014 | Trip report / report security | 1 | elect copy | |
| 50-0-28 | AN/FRT95A Overhaul NCTL DET Iceland Site Acceptance Test Procedure | SPAWAR | 26. June 2013 | Test proce | 1 | ||
| 50-0--29 | Tower Inspecton Report 600´ Guyed Tower no.2637, Grindavik Iceland | SPAWAR | 9/9/13 | Site specific Report | 1 | elect copy | |
| 50-0-29 | Tower Inspection Report 1000´ Guyed Tower no. 2636, Grindavik Iceland | SPAWAR | 9/9/13 | Site specific Report | 1 | elect copy | |
| 50-0-30 | FBS ANT-TRIP NRK_20140901 | SPAWAR | 9/9/14 | Site specific Report | 1 | elec copy | |
| 50-0-31 | Assessment Report. NRTF Iceland | NAVFAC | March 2015 | Site specific Report | 1 | elec copy | |
| 50-0-32 | Breaker and Metering Maintenance Test Report from EPI November 2015 | EPI | apr, 11 , 2015 | Site specific Report | 1 | elec copy | |
| 50-0-33 | Tower paint information sheets | Tower Inspection Inc. | 1 | elec copy | |||
| 50-0-34 | Short Circuit - Protective Device Coord. - Arch-Flash Analysis study | M.C. Dean, Inc. | dec,21 2015 | Site Report | 1 | ||
| 50-0-35 | API 653 Fuel Tank Inspection Reports | Facilities Dervel Contr | 8/31/16 | Safety | 1 | also elect copy | |
| 50-0-36 | Trip Report NCTAMS DET Iceland 09/28/2016 | SPAWAR | Nov. 15th 2017 | Site specific Report | 1 | also elect copy | |
| 50-0-37 | Áhættumat NRTF vegna jarðhræringa. 3549-001-MIN-001-V02 | ÖRUGG verkfræðistofa | 09.07.24 | Site specific áhættumat | 1 | elec copy |
| 50-1 | Military Standards & Instructions | ||||||
| Number | Title & other information | Vendor | date of issue | Categ. | Quant. | Remarks | |
| 50-1-1 | Naval Ships Technical Manual Chapter 670. Stowage, Handling, and disposal of hazardous general use consumables | Naval Sea systems command | 1. may 1997 | Safety | 1 | ||
| 50-1-2 | Opnavinst 5100.23H Safety Manual. Navy Occupational Safety and Health Program (NAVOSH) | DOD | 20. SEP 2023 | Safety | 1 | elect copy | |
| 50-1-3 | OPNAVINST 11320.23G - Shore Activities Fire Protection and Emergency Service Program | DON | 2/4/13 | Safety | 1 | elect copy | |
| 50-1-4 | OPNAVINST 5530.14E Navy Physical Security and law enforcement manual | DON | 1/30/09 | Security | 1 | elect copy | |
| 50-1-4 | NCTAMSLANTINST 5530.1D Antiterrorism/Force Protection (AT/FP), Physical Security, and Loss Prevention Program | DON | 12.dec. 2005 | NCTAMS | 1 | elect copy | |
| 50-1-4 | NCTAMSLANTINST C5530.4D Physical Security and Force Protection Plan | DON | 18.jul. 2005 | NCTAMS | 1 | ||
| 50-1-5 | OPNAVINST 5100.19F Navy Safety and Occupatonal health Program Manual for Forces Afloat | DON | 5. may 2019 | Safety | 1 | elect copy | |
| 50-1-5 | OPNAVINST 3120.32D Equipment Tag out Bill | DON | 16.july 2012 | 1 | elect copy | ||
| 50-1-6 | UFC 3-600-01 Unified Facilities Criteria. Fire Protection Engineering for Facilities | DOD | 17. april 2003 | Safety | 1 | elect copy | |
| 50-1-7 | DISA-Europe Circular 310-70-3 Procedures for proper installation of power, grounding and environmental control systems. | DisaEc | May 1, 1997 | Safety | 1 | elect copy | |
| 50-1-8 | DISA-Europe Circular 350-195-2 Test and Evaluations. Auxiliary Electric Power Systems | DisaEc | May 2002 | Safety | 1 | ||
| 50-1-9 | SPAWARINST 5100.9D, Navy Shore Electronics Safety Precausions | DON | Safety | 1 | |||
| 50-1-10 | Electronics Installation and maintenance book - Electonic circuits - NAVSEA 0967-LP-000-0120 - EIMB | Navel sea systems command | 1.march 1980 | standar / index | 1 | ||
| 50-1-11 | Communications Electronic Installation and maintenance books - NAVSEA: 0967-LP-000-0010 EIMB | Navel sea systems command | 9/1/79 | standar / index | 1 | ||
| 50-1-12 | Electronics Installation and Maintenance Book Installation Standards - NAVSEA: 0967-LP-000-0110 EIMB. NAVSHIPS 900.000.101 | NAVSEA TECHNICAL PUBLICATION | 9/1/77 | Standards | 1 | ||
| 50-1-13 | Electronics Installation and Maintenance Books - NAVSEA 0967-LP-000-0020 | NAVSEA TECHNICAL PUBLICATION | June 1974 | Standards | 1 | ||
| 50-1-14 | Electronics Installation and maintenance book - Electonic circuits - NAVSEA 0967-LP-000-0110 - EIMB. 3565/NAVAIR 16-1-529 / NAVELEX 0967-LP-624-6010 | Navel sea systems command | 9/1/77 | standar / index | 1 | ||
| 50-1-15 | Technical Manual - Electromagnetic Radiation Hazards (U) (Hazards to Ordnance) (U) NAVSEA OP | DON | 15. jul 1989 | Safety | 1 | ||
| 50-1-16 | Navairosh Requirements for the Shore Establishment. NAVAIR A1-NAOSH-SAF-000/p-5100-1 | Navair Systems Command | 2/1/86 | Safety | 1 | ||
| 50-1-17 | Ship/Shore Portable Electricial/Electronic Test Equipment Req. List (SPETERL) | Naval Surface Warfare | Safety | 1 | |||
| 50-1-18 | Evaluating Compliance with FCC Guidlines for Human Exposure to Radiofrequency Electromagnetic Fields. OET Bulletin 65 | Fedral Communications Commission Office of Engineering & Technology | Aug. 1997 | Safety | 1 | ||
| 50-1-19 | NAVSEA Technical Tag-Out Users Manual S0400-AD-URM-010/TUM | NAVSEA TECHNICAL PUBLICATION | 9/1/00 | Safety | 1 | ||
| 50-1-20 | OPNAVINST 5100.28 Hazardous Material Users Guide (HMUG) | DOD | 1/21/05 | Safety | 1 | ||
| 50-1-21 | Equipment identification code master index.(EIC) NAMSO 4790.E2579 | Jun 1986 | Safety | 1 | |||
| 50-1-22 | Shore Installation Process Handbook. Version 4.0. COMSPAWAR M-4720.1 | SPAWAR | November 12, 2014 | 1 | |||
| 50-1-23 | MIL-STD-3004 1&2 Quality Assurance for Bulk Fuels, Lubricants and related products | DOD | August 2018 | Safety | ONLY ELECTRONIC COPY | ||
| 50-1-24 | UFC 3-410-02 Lonworkds Direct Digital Cntrl for HVAC and other local bldgs sysems | DOD | 7/1/13 | Mechanical | 1 | Elec copy | |
| 50-1-25 | UFC 3-410-01 Heating, Ventilating and air Conditioning systems | DOD | 1/25/17 | Mechanical | 1 | elec copy | |
| 50-1-26 | UFC 3-420-01 Plumbing Systems | DOD | 10/26/15 | Mechanical | 1 | elec copy | |
| 50-1-27 | Material Safety Data Sheets MSDS / Inventory and Register/disposal Forms | 2/10/15 | Safety | 4 | 1 in library other by each firelocker | ||
| 50-1-28 | NCTAMSLANTINST 5100.7 Fall Protection Program | DOD | 22.july 2013 | Safety | 1 | also elect copy | |
| 50-1-28 | NAVTELCOMINST 2300.4C Configuration Status Accounting of Electronic eq. | DOD | 3.dec. 1986 | 1 | |||
| 50-1-28 | NAVCOMTELCOMINST 2313.1B - Quality Control and performance standards | DOD | 1/5/01 | 1 | |||
| 50-1-28 | NAVCOMTELCOMINST 4790.2 .- General purpose electronic test equipment (GPETE) Management | DOD | 10. june 1994 | 1 | |||
| 50-1-28 | NAVSEAINST 4790.8D - Ships Maintenance and Material Management (3-M) manual | DON | 17.june 2021 | Safety | ONLY ELECTRONIC COPY | ||
| 50-1-28 | COMNAVIFORINST 4790.1A | DON | 1/1/19 | Safety | ONLY ELECTRONIC COPY | ||
| 50-1-28 | COMNAVIFOINST 4790.2A | DON | 1/1/19 | Safety | ONLY ELECTRONIC COPY | ||
| 50-1-29 | OPNAVINST 4790.4F Ship´s maintenance and material Management (3M) system policy | DOD | 27.oct 2014 | Safety | 1 | ||
| 50-1-30 | OPNAVINST 5090.1 Environmental Readiness Program Manual | DOD | 25.june 2021 | Safety | 1 | elect copy | |
| 50-1-31 | DOD 6050.05 DoD Hazard Communication (HAZCOM) Program | DOD | 15. august 2006 | Safety | 1 | ||
| 50-1-32 | Depertment of Defense Dictionary of Military and Associated Terms | DOD | 12.april 2001 | Educ | ONLY ELECTRONIC COPY | ||
| 50-1-33 | UFC 3-420-02FA Compressed Air | DOD | 12/1/07 | Mechanical | ONLY ELECTRONIC COPY | ||
| 50-1-34 | UFC 3-501-01 Electrical Engineering | DOD | 10/6/15 | Mechanical | ONLY ELECTRONIC COPY | ||
| 50-1-35 | UFC 3-520-01 Interior Electrical Systems | DOD | 10/6/15 | Mechanical | ONLY ELECTRONIC COPY | ||
| 50-1-36 | UFC 3-520-05 Stationary Battery Areas | DOD | 5/1/15 | Mechanical | ONLY ELECTRONIC COPY | ||
| 50-1-37 | UFC 3-530-01 Interior and Exterior Lighting Systems and Controls | DOD | 4/1/15 | Mechanical | ONLY ELECTRONIC COPY | ||
| 50-1-38 | UFC 3-540-01 Engine Driven Generator Systems for Backup Power Applications | DOD | 8/1/14 | Mechanical | ONLY ELECTRONIC COPY | ||
| 50-1-39 | UFC 3-550-01 Exterior Electrical Power Distribution | DOD | 9/1/16 | Mechanical | ONLY ELECTRONIC COPY | ||
| 50-1-40 | Manual EM 385-1-1 Safety and Health Requirements | Department of Army | 30. nov 2014 | Safety | ONLY ELECTRONIC COPY | ||
| 50-1-41 | NTTP 3-07.2.3. Law enforcement and physical security | NTTP | year 2011 | Security | ONLY ELECTRONIC COPY | ||
| 50-1-42 | UG-2040-SHR, User's Guide on Controlling Locks, Keys and Access Cards | Safety | ONLY ELECTRONIC COPY | ||||
| 50-1-43 | S9086-WK-STM-020 Afloat Hazardous Materian control and Management guidelines Hazardous Material users Guide (HMUG) chapter 670 | DOD | 1. june 2012 | Safety | 1 | ||
| 50-1-44 | Inspection of Shore Facilities NAVFAC MO-322. Vol I & II | NAVFAC | March 1993 | Safety | 1 | ||
| 50-1-45 | NAVSEA OP 3565/NAVAIR 16-1-529 Vol I | NAVSEA TECHNICAL PUBLICATION | 2/1/03 | Safety | 1 | elec copy |
| 50-2 | Non-Military standards & Instructions | ||||||
| Number | Title & other information | Vendor | date of issue | Categ. | Quant. | Remarks | |
| 50-2-1 | Gagnamappa - vinnueftirlit ríkisins | vinnueftirlit ríkisins | 1 | ||||
| 50-2-2 | ACT on Working Environment, Health and Safety in Workplaces No. 46/1980 | vinnueftirlit ríkisins | 1 | ||||
| 50-2-3 | NFPA 70E Standard for Electrical Safety in the Workplace | NFPA | 2012 edition | 1 | |||
| 50-2-4 | NFPA 551 Guide for the Evaluation of Fire Risk Assessments | NFPA | 2016 edition | 1 | |||
| 50-2-5 | NFPA 75 Standard for the Fire Protection of Information Technology Equipment | NFPA | 2017 edition | 1 | |||
| 50-2-6 | NFPA 76 Standard for the Fire Protection of Telecommunications Facilities | NFPA | 2016 edition | 1 | |||
| 50-2-7 | NFPA 2001 Standard on Clean Agent Fire Extuinguishing Systems | NFPA | 2018 edition | 1 | |||
| 50-2-8 | Lifepack CRPlus Defibrillator. Operating Instructions | Physio Control | 1/1/18 | 1 | |||
| 50-2-9 | Lifepack CRPlus Defibrillator. Training/Orientation | Physio Control | 1/1/18 | 1CD | |||
| 50-2-10 | Arc Flash Protective Garments | Salisbury by Honeywell | August 2015 | 3 |
| 50-3 | Logs | ||||||
| Number | Title & other information | Vendor | date of issue | Categ. | Quant. | Remarks | |
| 50-3-0 | NRTF TAGOUT/LOCKOUT LOG | 01.JULY 09 | SAMEINAÐ FRÁ N62B N62C LOGS |
ATH að við erum líka með þetta óleyfilegt rafrænt sem best er að nota .
Það koma nýjar útgáfur af 3M kerfinu á ca 3mán fresti, þ.a. við erum ekki að merkja CD sérstaklega. CD er geymdur í Admin möppu hjá JL margskonar skjöl eru í einum folder merktur 20-4-1. það þarf bara að rúlla í gegnum þetta og finna hvað best er að nota hverju sinni
APPENDIX I-O page &P
LIST OF TECHNICAL AND ADMINISTRATIVE PUBLICATIONS
NRTF GRINDAVIK, ICELAND
File details come from the government source that posted it. Updated .