APP_1(I)-E_September_2025.xlsx
XLSX spreadsheet 21 KB Posted
- Attached to
- Naval Radio Transmitter Facility (NRTF) Support Services Federal contract opportunity
- Solicitation number
- N0018925R0037
About this file
The file is an equipment inventory spreadsheet for a Naval Radio Transmitter Facility (NRTF) located in Grindavik, Iceland, documenting various electronic test equipment and their calibration status. The inventory includes multiple types of measurement devices such as multimeters (Fluke and CTX models), power supplies, probes, current clamps, oscilloscopes, and specialized testing equipment like impedance bridges, megohm meters, and insulation testers. Most items have specific calibration dates, with many scheduled for calibration between 2024-2029, and many are marked with status codes like "CR CAL" (presumably "Calibration Required") or "NCR" (potentially "No Calibration Required").
This equipment inventory corresponds to a related naval contract opportunity (Solicitation Number N0018925R0037) for NRTF Support Services, which seeks a firm fixed-price contract for operating and maintaining the Low Frequency and Very Low Frequency Fixed Submarine Broadcast System. The contract is estimated to commence on 01 January 2026 with a 1-month transition period, followed by an 11-month base performance period and potential four 12-month options. The solicitation will be processed as Other than Full and Open Competition under international agreement provisions, with questions accepted until 08:00 AM EST on 03 September 2025, and the full service start date set for 01 February 2026.
View the file
Other files for this federal contract opportunity
Show all 30
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GRNDCSE
| LIST OF GENERAL PURPOSE ELECTRONIC TEST EQUIPMENT NRTF GRINDAVIK ICELAND | ||||||||||||||||||||||||||||||
| Test Equipment in TE Cabinet 01 | ||||||||||||||||||||||||||||||
| MODEL | SERIAL | SCHED_LAB | NOMEN | Manual No. | SCAT | UPDTE_DATE | WRK_CENTER | APP_PROC | ECN | NXT_ASSEM | ON_SITE | OWNER_STD | SERV_LBL | DATE_COMPL | DATE_CALIB | NXT_DUE_DT | REMARKS | GAGENUM | PHASE | EQ_TYPE | DELAY_DT | DELAY_ST | DELAY_LAB | CAL_LABSTD | PROB_ST | PROB_COM | SCATcode | Mes-IQ | Equipm. | |
| Status | Status | |||||||||||||||||||||||||||||
| 250DE | BP2401088 | ESI Impedance Bridge | PDF (1) | 05.24.2024 | 05.24.2027 | 4447 | CR | CAL. | ||||||||||||||||||||||
| 212159 | 2278 | Megger | PDF (1) | 6/6/24 | 6/6/27 | 4452 | CR | CAL. | ||||||||||||||||||||||
| R1M-A | 21850 | Meg-Ohm Meter | 30-0-8 | 6/6/24 | 6/6/27 | 4448 | CR | CAL. | ||||||||||||||||||||||
| 77III | 86450114 | CTX | MULTIMETER | 30-0-6 | 10/27/06 | BCAA | 6CMA8L1898 | Y | 4 | 8/23/05 | 12.18.2023 | 12.18.2029 | N | 4245 | CR | CAL. | ||||||||||||||
| 77III | 86600045 | CTX | MULTIMETER | 30-0-6 | 10/27/06 | BCAA | 6CMA8L3758 | Y | 4 | 8/23/05 | 12.18.2025 | 12.18.2029 | N | 4245 | CR | CAL. | ||||||||||||||
| 77III | 86600044 | CTX | MULTIMETER | 30-0-6 | 10/27/06 | BCAA | 6CMA8L0221 | Y | 4 | 8/23/05 | 19.18.2025 | 09.18.2029 | N | 4245 | CR | CAL. | ||||||||||||||
| 289 | 28890148 | TRUE RMS MULTIMETER | No manual | 03.17.2025 | 3.17.2028 | 4248 | CR | CAL. | ||||||||||||||||||||||
| 77AN | 46080614 | Digital Multimeter | 30-0-6 | 12.19.2023 | 12.19.2029 | 4245 | CR | CAL. | ||||||||||||||||||||||
| 87 III | 81200338 | True RMS Multimeter | 30-0-29 | 8/8/24 | 8/8/29 | 4249 | CR | CAL. | ||||||||||||||||||||||
| Bench Power Supply | No MIQ listing nor Calibration Required | OK | ||||||||||||||||||||||||||||
| Digital Ant. Current Receive | No MIQ listing nor Calibration Required | OK | ||||||||||||||||||||||||||||
| ML428N | M33050 | Anritsu Int./Field str. Meter | 30-0-4 | (No Battery) | Cal. Not Req. | 4434 | NCR | OK | ||||||||||||||||||||||
| 62 MINI | Fluke 62 IR Thermometer | Came from SPAWAR No MIQ listing nor Calibration Required | OK | |||||||||||||||||||||||||||
| Trays with Power Cords etc. | No MIQ listing nor Calibration Required | OK | ||||||||||||||||||||||||||||
| XP-1A | TIF XP-1A SF leak detector | Came from SPAWAR no MIQ listing nor Calibration Required | OK | |||||||||||||||||||||||||||
| P6015A | B028168 | High Voltage Probe | YES (1) | Cal. Not Req. | 4603 | NCR | OK | |||||||||||||||||||||||
| 860PL | M9410107 | MAR | INSULATION TESTER | 30-0-14 | 10/27/06 | BCAA | 6CMHYT0300 | N | 4 | 8/22/05 | 2/18/05 | Cal. Not Req. | 1 | N | 4453or4241 | NCR | OK | |||||||||||||
| MB27A | M25947 | Anritsu, Tripod | 30-0-4 | Cal. Not Req. | NCR | OK | ||||||||||||||||||||||||
| MP414B | M30150 | Anritsu, Loop Antenna | 30-0-4 | Cal. Not Req. | NCR | OK | ||||||||||||||||||||||||
| MP415B | M17750 | Anritsu, Rod Antenna | 30-0-4 | Cal. Not Req. | NCR | OK | ||||||||||||||||||||||||
| PP4300 | 430FDA002 | POWER PLATFORM | 30-0-53 | 4/15/09 | Cal. Not Req. | 4243 | NCR | OK | ||||||||||||||||||||||
| 4300RS232 | R232DA003 | CURRENT PROBE | 30-0-54 | Cal. Not Req. | 4999 | NCR | OK | |||||||||||||||||||||||
| TR2023 | 2023EA002 | AC CURRENT PROBE | 30-0-53 | 2/2/09 | Cal. Not Req. | 4999 | NCR | OK | ||||||||||||||||||||||
| TR2500A | 80209078 | CURRENT PROBE | 30-0-53 | 4/15/09 | Cal. Not Req. | 4999 | NCR | OK | ||||||||||||||||||||||
| TR2500A | 80209076 | CURRENT PROBE | 30-0-53 | 4/15/09 | Cal. Not Req. | 4999 | NCR | OK | ||||||||||||||||||||||
| TR2500A | 80209075 | CURRENT PROBE | 30-0-53 | 4/15/09 | Cal. Not Req. | 4999 | NCR | OK | ||||||||||||||||||||||
| Power Platform Training Mat. | 30-0-55 | |||||||||||||||||||||||||||||
| 3640 | 175000PFDV | AEMC GND.RES.TESTER | YES (1) | 11.15.2023 | 11.15.2026 | CR | CAL. | |||||||||||||||||||||||
| PM3094AN | DM635019 | FLUKE O.SCOPE | YES (1) | 06-26-19 | 1/7/22 | 4306 | CR | IN CAL. | ||||||||||||||||||||||
| TDS3012BNV | B042872 | TEKTRONIX O.SCOPE | YES (1) | 02.13.2025 | 02.13.2029 | 4306 | CR | CAL. | ||||||||||||||||||||||
| R1LB | 2010411R1LB | MICROOHMMERTER | YES (1) | 4/6/24 | 4/6/27 | 4445 | CR | CAL. | ||||||||||||||||||||||
| CM 1-2 | K00510618 | Current Clamp Meter | No MIQ listing nor Calibration Required | OK | ||||||||||||||||||||||||||
| LCR-4000 | 24001943 | Digital LCR Meter | No MIQ listing nor Calibration Required | OK | ||||||||||||||||||||||||||
| VC-2020 | K2011335124 | Analog Multimeter | No MIQ listing nor Calibration Required | OK |
APPENDIX I-E
I-E page 1 of 1
I-E page 2 of 2