N00189-07-R-0022-Atch11-MaritimeBunkers.doc

DOC document 36 KB Posted

Attached to
HUSBANDING SERVICE PROVIDER
Solicitation number
N0018907R0022
Issued by

About this file

DRAFT ATCH 11 MARITIME BUNKERS

View the file

Other files

File Type Posted
N00189-07-R-00220008.doc DOC document
N00189-07-R-0022-Atch13-0007QASP.doc DOC document
Atch18N00189-07-R-0022HSPPre-ProposalConferenceAttendeeList.doc DOC document
N00189-07-R-0022-Atch2-PricingSchedule-0007.xls XLS spreadsheet
N00189-07-R-00220007.doc DOC document
N00189-07-R-0022-Atch2-PricingSchedule-0006.xls XLS spreadsheet
N00189-07-R-0022-0006.doc DOC document
1_N00189-07-R-0022-Atch9-Eggs.doc DOC document
1_N00189-07-R-0022-Atch14-PVCRTable.xls XLS spreadsheet
1_N00189-07-R-0022-Atch12-Glossary.doc DOC document
1_N00189-07-R-0022-Atch16-SampleTask-LOGREQ.doc DOC document
2_N00189-07-R-0022-Atch13-QASP.doc DOC document
1_N00189-07-R-0022-Atch11-MaritimeBunkers.doc DOC document
1_N00189-07-R-0022-Atch15-MAPS.doc DOC document
1_N00189-07-R-0022-Atch1-ClassShips.doc DOC document
N00189-07-R-00220005.doc DOC document
1_N00189-07-R-0022-Atch4-PastPerfQuestionaire.doc DOC document
1_N00189-07-R-0022-Atch8-Bread.doc DOC document
1_N00189-07-R-0022-Atch3-PastPerfDataSheet.doc DOC document
2_N00189-07-R-0022-Atch2-PricingSchedule.xls XLS spreadsheet
1_N00189-07-R-0022-Atch6-OOTW.doc DOC document
1_N00189-07-R-0022-Atch7-WaterSpecs.doc DOC document
1_N00189-07-R-0022-Atch10-LetterSanitaryInspec.doc DOC document
Atch17commentsfromindustry.xls XLS spreadsheet
2_N00189-07-R-0022-Atch5-PWS.doc DOC document
PRE-PROPOSALCONFERENCE22MAY2007.doc DOC document
1_N00189-07-R-0022-Atch5-PWS.doc DOC document
N00189-07-R-0022-Atch15-MAPS.doc DOC document
1_N00189-07-R-0022-Atch13-QASP.doc DOC document
N00189-07-R-0022-Atch16-SampleTask-LOGREQ.doc DOC document
N00189-07-R-00220004RELEASED14MAY2007.doc DOC document
1_N00189-07-R-0022-Atch2-PricingSchedule.xls XLS spreadsheet
N00189-07-R-00220001.doc DOC document
N00189-07-R-00220003.doc DOC document
N00189-07-R-00220002.doc DOC document
N00189-07-R-0022-Amendment02CancelPre-solicitationinterview.doc DOC document
20070405145833.zip ZIP file
N00189-07-R-0022-Atch3-PastPerfDataSheet.doc DOC document
N00189-07-R-0022-Atch7-WaterSpecs.doc DOC document
N00189-07-R-0022-Atch2-PricingSchedule.xls XLS spreadsheet
N00189-07-R-0022-Issued30Mar.doc DOC document
N00189-07-R-0022-Atch9-Eggs.doc DOC document
N00189-07-R-0022-Atch1-ClassShips.doc DOC document
N00189-07-R-0022-Atch6-OOTW.doc DOC document
N00189-07-R-0022-Atch4-PastPerfQuestionaire.doc DOC document
N00189-07-R-0022-Atch10-LetterSanitaryInspec.doc DOC document
N00189-07-R-0022-Atch14-PVCRTable.xls XLS spreadsheet
N00189-07-R-0022-Atch13-QASP.doc DOC document
N00189-07-R-0022-Atch12-Glossary.doc DOC document
N00189-07-R-0022-Atch8-Bread.doc DOC document
Show 40 more

Latest 50 of 51 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FISC NORFOLK

ATTACHMENT # 11

FUEL SPECIFICATIONS

CONTRACTORS ARE TO GO TO THE WEBSITE

http://www.desc.dla.mil

FOR THE UPDATED OVERSEAS BULLETIN FOR SHIP’ BUNKERS. THE BULLETIN OUTLINES ALL THE CONTRACTS DESC HAS AWARDED TO DATE AND THE PROCEDURES NEEDED TO PLACE ORDERS UNDER THESE CONTRACTS.

Please be advised that the Defense Fuel Supply Center has been renamed to the Defense Energy Support Center. This was accomplished on January 16, 1998 by the Department of Defense Reform Initiative Directive #21.

COMMERCIAL MARINE GAS OIL MINIMUM SPECIFICATION REQUIREMENTS FOR SHIPS' BUNKERS (DFSC OCT 1996) (REV)

Offered product shall conform to the following requirements which are suitable for Marine Gas Turbine.

TEST

METHOD

REQUIREMENTS

1.

Cetane Number

ASTM D 613

42 min or

Cetane Index

ASTM D 976

43 min

NOTE:

A Cetane Number of 40 minimum, or a Cetane Index of 41 minimum, is acceptable provided the 90 percent Distillation Point does not exceed a maximum of 338oC.

2.

Appearance @ 21oC or ambient temp. (whichever higher)Visual

Clear & Bright or

Water & Sediment

ASTM D 2709

0.05 vol % max

3.

Distillation, 90% point

ASTM D 86

357oC max

4.

Flash Point

ASTM D 93

60oC min

NOTE: The flash point value is absolute and no value less than 60oC is permissible.

5.

Cloud Point

ASTM D 2500

-1.1oC (30oF) max

NOTE: Cloud Point results will be evaluated based upon bunkering location.

6.

Viscosity @ 40oC

ASTM D 445

1.7 - 4.5 cst

7.

Color

ASTM D 1500

3 max

NOTE FOR DOMESTIC ITEMS: This Color test requirement is deleted if red or blue dye has been added in compliance with U.S. Environmental Protection Agency or Internal Revenue Service regulations; however, the resulting fuel/dye blend must have a red tint. It shall not be visually brown or darker in appearance.

8.

Density @ 15oC

ASTM D 1298

876 kg/m3 max.

9.

Carbon Residue on 10% bottoms

ASTM D 524

0.35 mass % max

ASTM D 189

10.

Ash

ASTM D 482

0.01 mass % max

11.

Sulfur

ASTM D 4294,

1.0 mass % max.

ASTM D 1552, or

ASTM D 2622

12.

Corrosion

ASTM D 130

3 max

13.

Distillate Fuel (fuel shall contain no residual)

None

100%