This is a First Article Test Procedure for Electromagnetic Compatibility (EMC) testing of the IM-272A/WDQ Radiacmeter, an Air Monitor for Radioactive Particles, under Contract No. N00167-19-C-0005 issued to Spectral Labs Incorporated (SLI). The procedure establishes the testing framework required to verify that the equipment meets electromagnetic interference control requirements for installation aboard naval ships, specifically conforming to MIL-STD-461G for below-deck equipment.
The test procedure requires eleven distinct EMC tests covering both conducted and radiated emissions and susceptibility across frequency ranges from 30 Hz to 18 GHz. Tests include CE101 and CE102 (conducted emissions on power leads), CS101, CS109, CS114, CS115, and CS116 (conducted susceptibility across various configurations and frequency ranges), RE101 and RE102 (radiated emissions), and RS101 and RS103 (radiated susceptibility). The test article must be configured with front cover and access door installed, connected to 115 VAC and 28 VDC power supplies, with an external isolation valve controller and two automatic isolation valves (Government-furnished property) in the open position. Acceptance criteria specify that the equipment exhibit no deviations or anomalies during susceptibility testing, with no Rad Alarms, system faults, or GUI anomalies permitted. Testing occurs under standard laboratory environmental conditions and can be conducted in any sequence. A Functional Test must be performed immediately before and after the complete test suite. Test results must be recorded on provided data sheets with detailed documentation of anomalies, thresholds, and test observations, including photographs of test setup and performance data.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IM-272A/WDQ Electromagnetic Compatibility Test Procedure 001565 Rev. X4
IM-272A/WDQ
First Article Test Procedure Electromagnetic Compatibility (EMC)
17 Nov 2020
Contract No. N00167-19-C-0005
CDRL A001
DID DI-NDTI-80603A
Unclassified
Contractor: Spectral Labs Incorporated (SLI) 15920 Bernardo Center Drive
San Diego, CA 92127
DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors;
Administrative/Operational Use: 31 October 2019. Other requests for this document shall be referred to Naval Sea
Systems Command (NAVSEA 04ND).
This document could contain technical data, the export of which is restricted by the U.S. arms export control act (AECA) (TITLE 22, U.S.C. SEC 2751, ET SEQ.) Or the export administration act of 1979, as amended (TITLE 50, U.S.C., APP.2401, ET SEQ.).
NSWCCD IM-272A/WDQ Electromagnetic Compatibility Test Procedure
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
I Record of Changes
Revision Change Date Approval X1 Initial Release 10/31/2019 E. Ackermann X2 Update after Gov review 01/02/2020 E. Ackermann X3 Incorporate Gov comments on X2 01/16/2020 E. Ackermann X4 Update with final gov’t comments 11/17/2020 J. Adams
II Table of Contents
I Record of Changes II Table of Contents
1.0 Introduction
1.1 Purpose of Test
1.2 System to be Tested
1.2.1 Nomenclature
1.2.2 Model Number
1.2.3 Type of Test
1.2.4 Applicable Performance and Testing Specification Reference
1.3 Test Requirements
1.3.1 Test Article Configuration
1.3.2 Required Tests:
1.3.3 Acceptance Criteria:
1.3.4 Environmental Criteria
1.3.5 Table of Tests
1.4 Reference Documents
2.0 Support Requirements
3.0 Test Procedures
3.1 IM-272A/WDQ – CE101 conducted emissions, power leads, 30 Hz to 10 kHz
3.2 IM-272A/WDQ – CE102 conducted emissions, power leads, 10 kHz to 10 MHz
3.3 IM-272A/WDQ – CS101 conducted susceptibility, power leads, 30 Hz to 150 kHz
3.4 IM-272A/WDQ – CS109 conducted susceptibility, structure current, 60 Hz to 100 kHz
3.5 IM-272A/WDQ – CS114 conducted susceptibility, bulk cable injection, 10 kHz to 200 MHz
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
3.6 IM-272A/WDQ – CS115 conducted susceptibility, bulk cable injection, impulse excitation
3.7 IM-272A/WDQ – CS116 conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz
3.8 IM-272A/WDQ – RE101 radiated emissions, magnetic field, 30 Hz to 100 kHz
3.9 IM-272A/WDQ – RE102 radiated emissions, electric field, 10 kHz to 18 GHz
3.10 IM-272A/WDQ – RS101 radiated susceptibility, magnetic field, 30 Hz to 100 kHz
3.11 IM-272A/WDQ – RS103 radiated susceptibility, electric field, 2 MHz to 40 GHz 11
3.12 Cautions and Safety Warnings
4.0 Data Sheet
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
1.0 Introduction
This document describes the Electromagnetic Compatibility (EMC) test for the IM-272A/WDQ Radiacmeter, Air Monitor for Radioactive Particles (radiacmeter).
1.1 Purpose of Test
The objective of this test is to ensure that the IM-272A/WDQ meets the requirements for the control of electromagnetic interference as may be encountered aboard naval ships.
1.2 System to be Tested
1.2.1 Nomenclature
Radiacmeter, Air Monitor for Radioactive Particles (radiacmeter)
1.2.2 Model Number
IM-272A/WDQ
1.2.3 Type of Test
First Article, Production Inspection (CE102 and RE102 only).
1.2.4 Applicable Performance and Testing Specification Reference Requirement Paragraphs: 3.2.3 Electromagnetic Compatibility (EMC). The radiacmeter shall conform to the requirements of MIL-STD-461 for below deck equipment (tests CE101, CE102, CS101, CS109, CS114, CS115, CS116, RE101, RE102, RS101, and RS103)
Test Paragraph: 4.5.4 EMC test. The requirements of 3.2.3 shall be verified by tests performed in accordance with MIL-STD-461. For this testing, the radiacmeter shall provide 115 VAC power and 28 VDC power via Jack J3 to an external isolation valve controller that is connected to two automatic isolation valves, with the valves in the open position. An isolation valve controller and two automatic isolation valves will be provided by the procuring activity.
For production inspection only, tests CE102 and RE102 shall be performed.
1.3 Test Requirements
1.3.1 Test Article Configuration
The IM-272A/WDQ test article shall have its front cover and access door installed and secure during all EMC testing. A power cord shall be connected to supply power and the external valve control cable shall be attached for all tests. The unit will be operated in its normal operating mode during all EMC tests with the Diagnostic screen selected for visual detection of anomalies during testing. The unit shall be configured to log counts per second data every second (CPS Log) and the entire data set log (Full Log) every minute during susceptibility testing to support anomaly detection and determination of anomaly root cause.
1.3.2 Required Tests:
MIL-STD-461G for below deck (surface ship and submarine) equipment (tests CE101, CE102, CS101, CS109, CS114, CS115, CS116, RE101, RE102, RS101, and RS103)
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
1.3.3 Acceptance Criteria:
For susceptibility testing, anomalies will be determined by watching the Front Panel during all testing, either in person or through video monitoring. A Rad Alarm, system fault, or anomalous behavior of the GUI screen or front panel indicators will constitute a test failure. Rad Alarms and Fault Codes are latched and can be recorded and then acknowledged following the completion of the test or sub-test in which they occurred. The CPS Log and Full Log will be viewed where indicated in the test procedures to identify any anomalous behavior in the detector signal chain or ancillary circuits. All figure references below can be found in MIL-STD-461G.
1. CE101: Limits per figure CE101-2, relaxed based on load current as described in the figure. For example, if the fundamental current is 2A, the relaxation is 20 Log 2 = 6 dB.
2. CE102: Limits per figure CE102-1, relaxed by 6 dB for 115V equipment per the figure.
3. CS101: No deviations or anomalies with applied voltage and power limits per figures
CS101-1, curve #1 (source above 28V) and CS101-2.
4. CS109: No deviations or anomalies with applied signals per figure CS109-1.
5. CS114: No deviations or anomalies when subjected to an injection probe drive level calibrated to the appropriate current limit from Figure CS114-1. Use the limits for Ships (Metallic) (Below Decks) from Table VI. Note: the values for Submarine (Internal) also apply but are less stringent than the Ships (Metallic) (Below Decks) requirement, so can be ignored for this test.
6. CS115: No deviations or anomalies when subjected to a pre-calibrated signal having rise and fall times, pulse width, and amplitude as specified in Figure CS115-1 at a 30 Hz rate for 1 minute.
7. CS116: No deviations or anomalies when subjected to a signal having the waveform shown in Figure CS116-1 and having a maximum current as specified in Figure CS116-2.
Compliance shall be demonstrated at the following frequencies: 0.01, 0.1, 1, 10, 30, and 100 MHz. The test signal repetition rate shall be no greater than one pulse per second and no less than one pulse every two seconds. The pulses shall be applied for a period of five minutes.
8. RE101: Magnetic field emissions shall not be radiated in excess of the levels shown in Figure RE101-2 at a distance of 7 cm.
9. RE102: Electric field emissions shall not be radiated in excess of those shown in Figure RE102-1 (Below Deck) or Figure RE102-2 (Internal). Above 30 MHz, the limits shall be met for both horizontally and vertically polarized fields.
10. RS101: No deviations or anomalies when subjected to the magnetic fields shown in Figure RS101-1.
11. RS103: No deviations or anomalies when subjected to the radiated electric fields listed in Table VII and modulated per paragraph 5.20.3.4. Use the limits for Ships (Metallic)(Below Decks) from Table VII. Note: the values for Submarine (Internal) also apply but are less stringent than the Ships (Metallic)(Below Decks) requirement, so can be ignored for this test. Up to 30 MHz, the requirement shall be met for vertically polarized fields. Above 30 MHz, the requirement shall be met for both horizontally and vertically polarized fields. Circular polarized fields are not acceptable. Note: testing beyond 18 GHz has not been required by the procurement agency so will not be conducted.
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
1.3.4 Environmental Criteria
Unless otherwise specified, no special criteria is required. Perform test in standard laboratory environmental conditions.
1.3.5 Table of Tests
Note that these tests can be conducted in any order.
Test Name Paragraph Specification Requirement CE101 conducted emissions, power leads, 30 Hz to 10 kHz
3.1 P&T Specification 3.2.3
CE102 conducted emissions, power leads, 10 kHz to 10 MHz
3.2 P&T Specification 3.2.3
CS101 conducted susceptibility, power leads, 30 Hz to 150 kHz
3.3 P&T Specification 3.2.3
CS109 conducted susceptibility, structure current, 60 Hz to 100 kHz
3.4 P&T Specification 3.2.3
CS114 conducted susceptibility, bulk cable injection, 10 kHz to 200 MHz
3.5 P&T Specification 3.2.3
CS115 conducted susceptibility, bulk cable injection, impulse excitation
3.6 P&T Specification 3.2.3
CS116 conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz
3.7 P&T Specification 3.2.3
RE101 radiated emissions, magnetic field, 30 Hz to 100 kHz
3.8 P&T Specification 3.2.3
RE102 radiated emissions, electric field, 10 kHz to 18 GHz
3.9 P&T Specification 3.2.3
RS101 radiated susceptibility, magnetic field, 30 Hz to 100 kHz
3.10 P&T Specification 3.2.3
RS103 radiated susceptibility, electric field, 2 MHz to 40 GHz
3.11 P&T Specification 3.2.3
1.4 Reference Documents
The following document(s) are applicable for IM-272A/WDQ EMC test.
Title Number Date Source
IM-272A/WDQ
Performance and Testing Specification
REVISION 02
N/A 08 Mar 2019 Naval Surface Warfare Center
Carderock Functional Test Procedure 001551 SLI
REQUIREMENTS FOR THE CONTROL
OF ELECTROMAGNETIC
INTERFERENCE CHARACTERISTICS
OF SUBSYSTEMS AND EQUIPMENT
MIL-STD-
461G
11 December 2015 Department of Defense
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
2.0 Support Requirements
This test requires specialized facilities and equipment that will be provided by an outside lab.
The test personnel are required to have a detailed knowledge of IM-272A/WDQ operation and maintenance procedures. There are no unusual electrical, hydraulic or pneumatic requirements. A detailed list of Test Equipment will be provided in the Test Report per Section 4.0.
Government Furnished Property: This test requires an external isolation valve controller that is connected to two automatic isolation valves. These items are not commercially available and must be provided by the Government.
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
3.0 Test Procedures
Note: A Functional Test Part 2 must be performed just prior to initiation of this suite of tests and then immediately following their completion. The tests may be conducted in any order. Record data in Section 4.
3.1 IM-272A/WDQ – CE101 conducted emissions, power leads, 30 Hz to 10 kHz
3.1.1 Perform a Functional Test of the IM-272A/WDQ and record on the Functional Test data sheet.
3.1.2 Perform tests according to MIL-STD-461G section 5.4.3. During the test, measure and record the load current for determining the CE101 limits.
3.1.3 Record results according to MIL-STD-461G section 5.4.3.5
3.2 IM-272A/WDQ – CE102 conducted emissions, power leads, 10 kHz to 10 MHz
3.2.1 Perform a Functional Test of the IM-272A/WDQ and record on the Functional Test data sheet.
3.2.2 Perform tests according to MIL-STD-461G section 5.5.3.
3.2.3 Record results according to MIL-STD-461G section 5.5.3.5
3.3 IM-272A/WDQ – CS101 conducted susceptibility, power leads, 30 Hz to 150 kHz
3.3.1 Perform a Functional Test of the IM-272A/WDQ and record on the Functional Test data sheet.
3.3.2 Perform tests according to MIL-STD-461G section 5.7.3. During the test monitor the performance of the IM-272A/WDQ. Note any abnormalities by observation and through viewing the CPS Log and determine the threshold limits according to section 5.7.3.4 c (4) (b), Following the completion of the test, download and label the CPS Log and Full Log files to support root case analysis.
3.3.3 Record results according to MIL -STD-461G section 5.7.3.5
3.4 IM-272A/WDQ – CS109 conducted susceptibility, structure current, 60 Hz to 100 kHz
3.4.1 Perform a Functional Test of the IM-272A/WDQ and record on the Functional Test data sheet.
3.4.2 Perform tests according to MIL-STD-461G section 5.11.3 for the first set of test points.
During the test, monitor the performance of the IM-272A/WDQ. Note any abnormalities
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
by observation and through viewing the CPS Log and determine the threshold limits according to section 5.11.3.4 d.
3.4.3 Repeat 3.4.2 herein for each diagonal extreme across all surfaces per 5.11.3.3 (2) (c) for deck resting equipment.
3.4.4 Repeat 3.4.2 between cable armor, which is terminated at the IM-272A/WDQ, and the single point ground established for the test setup. This requirement shall also apply to cable shields and conduit, unless they have a single point ground. Skip this step if none of the cables have armor or shields.
3.4.5 Record results according to MIL-STD-461G section 5.11.3.5. Following the completion of the test, download and label the CPS Log and Full Log files to support root case analysis.
3.5 IM-272A/WDQ – CS114 conducted susceptibility, bulk cable injection, 10 kHz to 200 MHz
3.5.1 Perform a Functional Test of the IM-272A/WDQ and record on the Functional Test data sheet.
3.5.2 Perform tests according to MIL-STD-461G section 5.12.3 for the entire power cable bundle. During the test, monitor the performance of the IM-272A/WDQ. Note any abnormalities by observation and through viewing the CPS Log and determine the threshold limits according to section 5.12.3.4.c (2)(e).
3.5.3 Repeat 3.5.2 herein for the following cases; the power leads (including returns and grounds) of the power cable grouped separately, the power leads of the power cable with the returns and grounds removed, and the entire external valve controller cable bundle.
3.5.4 Record results according to MIL-STD-461G section 5.12.3.5. Following the completion of the test, download and label the CPS Log and Full Log files to support root case analysis.
3.6 IM-272A/WDQ – CS115 conducted susceptibility, bulk cable injection, impulse excitation
3.6.1 Perform a Functional Test of the IM-272A/WDQ and record on the Functional Test data sheet.
3.6.2 Perform tests according to MIL-STD-461G section 5.13.3 for the entire power cable bundle. During the test, monitor the performance of the IM-272A/WDQ. Note any abnormalities by observation and through viewing the CPS Log and determine the threshold limits according to section 5.13.3.4.c (2) (d).
3.6.3 Repeat 3.6.2 herein for the following cases; the power leads (including returns and grounds) of the power cable grouped separately, the power leads of the power cable with the returns and grounds removed, and the entire external valve controller cable bundle.
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
3.6.4 Record results according to MIL -STD-461G section 5.13.3.5. Following the completion of the test, download and label the CPS Log and Full Log files to support root case analysis.
3.7 IM-272A/WDQ – CS116 conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz
3.7.1 Perform a Functional Test of the IM-272A/WDQ and record on the Functional Test data sheet.
3.7.2 Perform tests according to MIL-STD-461G section 5.14.3 for the entire power cable bundle. During the test, monitor the performance of the IM-272A/WDQ. Note any abnormalities by observation and through viewing the CPS Log and determine the threshold limits according to section 5.14.3.4.c (5).
3.7.3 Repeat 3.7.2 herein for the following cases; the high side power lead of the power cable with the returns and grounds removed and the entire external valve controller cable bundle.
3.7.4 Record results according to MIL-STD-461G section 5.14.3.5. Following the completion of the test, download and label the CPS Log and Full Log files to support root case analysis.
3.8 IM-272A/WDQ – RE101 radiated emissions, magnetic field, 30 Hz to 100 kHz
3.8.1 Perform a Functional Test of the IM-272A/WDQ and record on the Functional Test data sheet.
3.8.2 Perform tests according to MIL-STD-461G section 5.17.3.
3.8.3 Record results according to MIL -STD-461G section 5.17.3.5
3.9 IM-272A/WDQ – RE102 radiated emissions, electric field, 10 kHz to 18 GHz
3.9.1 Perform a Functional Test of the IM-272A/WDQ and record on the Functional Test data sheet.
3.9.2 Perform tests according to MIL-STD-461G section 5.18.3.
3.9.3 Record results according to MIL -STD-461G section 5.18.3.5
3.10 IM-272A/WDQ – RS101 radiated susceptibility, magnetic field, 30 Hz to 100 kHz
3.10.1 Perform a Functional Test of the IM-272A/WDQ and record on the Functional Test data sheet.
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
3.10.2 Perform tests according to MIL-STD-461G section 5.20.3. During the test monitor the performance of the IM-272A/WDQ by observation and through viewing the CPS Log and investigate any anomalies per section 5.20.3.4.c. Following the completion of the test, download and label the CPS Log and Full Log files to support root case analysis.
3.10.3 Record results according to MIL -STD-461G section 5.20.3.5
3.11 IM-272A/WDQ – RS103 radiated susceptibility, electric field, 2 MHz to 40 GHz
3.11.1 Perform a Functional Test of the IM-272A/WDQ and record on the Functional Test data sheet.
3.11.2 Perform tests according to MIL-STD-461G section 5.21.3. During the test, monitor the performance of the IM-272A/WDQ. Note any abnormalities by observation and through viewing the CPS Log and determine the threshold limits according to section 5.21.4.4.b(7). Following the completion of the test, download and label the CPS Log and Full Log files to support root case analysis. Note: testing beyond 18 GHz has not been required by the procurement agency so will not be conducted.
3.11.3 Record results according to MIL-STD-461G section 5.21.3.5
3.12 Cautions and Safety Warnings
Take appropriate precautions required for safe operation during EMC tests.
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
4.0 Data Sheet
Unit Tested:
Step Measurement or Observation
Required Value
Observed Value
Pass/Fail
3.1.1 Functional Test Pass
3.1.2 Record the load current
for determining the
CE101 limits N/A
3.1.3
Record Results
Specific limits per paragraph
1.3.3 herein
3.2.1 Functional Test Pass
3.2.3
Record Results
Specific limits per
3.3.1 Functional Test Pass
3.3.2 Record anomalies and
thresholds N/A
3.3.3 Record Results No
anomalies
3.4.1 Functional Test Pass
3.4.2/3.4.3/3.4.4 Record anomalies and thresholds N/A
3.4.5 Record Results No
3.5.1 Functional Test Pass
3.5.2/3.5.3 Record anomalies and thresholds N/A
3.5.4 Record Results No
3.6.1 Functional Test Pass
3.6.2/3.6.3 Record anomalies and thresholds N/A
3.6.4 Record Results No
3.7.1 Functional Test Pass
3.7.2/3.7.3 Record anomalies and thresholds N/A
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
3.7.4 Record Results No
3.8.1 Functional Test Pass
3.8.3
Record Results
Specific limits per
3.9.1 Functional Test Pass
3.9.3
Record Results
Specific limits per
3.10.1 Functional Test Pass
3.10.2 Record anomalies and
conditions N/A
3.10.3 Record Results No
3.11.1 Functional Test Pass
3.11.2 Record anomalies and
thresholds N/A
3.11.3 Record Results No
Test Equipment Used
Equipment Model Manufacturer Calibration Due
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
Diagram of test set up
Spectral Labs 2019 DISTRIBUTION STATEMENT C: Distribution authorized to US Government Agencies and their contractors; Administrative/Operational Use: 31
October 2019. Other requests for this document shall be referred to Naval Sea Systems Command (NAVSEA 04ND).
Attach photographs of test setup and test performance, any test notes and the Functional Test data sheet to body of procedure.
Test observations
Test performed by: _________________________________________
Venue: ___________________________________________________
Date: ____________________________________________________
Reviewed by: ______________________________________________
| I Record of Changes |
| II Table of Contents |
| 1.0 Introduction |
| 1.1 Purpose of Test |
| 1.2 System to be Tested |
| 1.2.1 Nomenclature |
| 1.2.2 Model Number |
| 1.2.3 Type of Test |
| 1.2.4 Applicable Performance and Testing Specification Reference |
| 1.3 Test Requirements |
| 1.3.1 Test Article Configuration |
| 1.3.2 Required Tests: |
| 1.3.3 Acceptance Criteria: |
| 1.3.4 Environmental Criteria |
| 1.3.5 Table of Tests |
1.4 Reference Documents
| 2.0 Support Requirements |
| 3.0 Test Procedures |
| 3.1 IM-272A/WDQ – CE101 conducted emissions, power leads, 30 Hz to 10 kHz |
| 3.2 IM-272A/WDQ – CE102 conducted emissions, power leads, 10 kHz to 10 MHz |
| 3.3 IM-272A/WDQ – CS101 conducted susceptibility, power leads, 30 Hz to 150 kHz |
| 3.4 IM-272A/WDQ – CS109 conducted susceptibility, structure current, 60 Hz to 100 kHz |
| 3.5 IM-272A/WDQ – CS114 conducted susceptibility, bulk cable injection, 10 kHz to 200 MHz |
| 3.6 IM-272A/WDQ – CS115 conducted susceptibility, bulk cable injection, impulse excitation |
| 3.7 IM-272A/WDQ – CS116 conducted susceptibility, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz |
| 3.8 IM-272A/WDQ – RE101 radiated emissions, magnetic field, 30 Hz to 100 kHz |
| 3.9 IM-272A/WDQ – RE102 radiated emissions, electric field, 10 kHz to 18 GHz |
| 3.10 IM-272A/WDQ – RS101 radiated susceptibility, magnetic field, 30 Hz to 100 kHz |
| 3.11 IM-272A/WDQ – RS103 radiated susceptibility, electric field, 2 MHz to 40 GHz |
| 3.12 Cautions and Safety Warnings |
4.0 Data Sheet