Attachment J-14 - Arrival Inspection Check-Off Sheet.pdf

PDF 29 KB Posted

Attached to
Maintenance Support for Inactive Ships in Bremerton, WA and CG/LSD Modernization Support in San Diego, CA
Solicitation number
N00024-17-R-4404
Issued by

About this file

Attachment J-14

View the file

Other files

File Type Posted
N0002417C4404_J&A_Redacted.pdf PDF
N00024-17-R-4404_Amendment_0003.docx.pdf PDF
Attachment_S-3_-_Past_Performance_Questionnaire.docx DOCX document
N00024-17-R-4404_Conformed_RFP_through_Amendment_0003.pdf PDF
Bidder's_Q&A__3.pdf PDF
CDRL49-52.pdf PDF
N00024-17-R-4404_Amendment_00002.pdf PDF
Attachment_S-3_-_Past_Performance_Questionnaire.docx DOCX document
CDRL45-48.PDF PDF
Bidder's_Q&A__2.pdf PDF
N00024-17-R-4404_Conformed_through_A0002.pdf PDF
Attachment_S-6_Pre_Award_Accounting_System_Checklist.docx DOCX document
Bidder's_Q&A__1.pdf PDF
N00024-17-R-4404_Amendment_0001.docx.pdf PDF
Attachment J-2 - Safe Stowage Check-off List.pdf PDF
Attachment J-6 and J-7 Government Furnished Property.pdf PDF
Attachment J-3 - Repair Request Work Order —
Attachment J-18 - Mooring and Security Inspection Log.xlsx XLSX spreadsheet
Attachment J-23 - Quality Assurance Surveillance Plan.pdf PDF
Attachment J-1 - List of assigned Vessels.XLS XLS spreadsheet
Attachment J-19 - Strike Ship Check-off List.pdf PDF
N00024-17-R-4404.pdf PDF
Attachment J-11 - Quality Assurance Surveillance Form for DH.pdf PDF
Attachment S-2 - Past Performance Data.docx DOCX document
Attachment J-13 - Integrity Inspection.pdf PDF
Attachment J-12 - Quality Assurance Surveillance Form for FF.pdf PDF
Attachment J-20 - Polychlorinated Biphenyl —
Attachment J-16 - Security Violation Report.pdf PDF
Attachment S-3 - Past Performance Questionnaire.docx DOCX document
Attachment J-22 - Contract Security Classification Specification, DD Form 254.pdf PDF
Attachment J-15 - Inspection of Disposal Vessel.pdf PDF
Exhbt A - DD Form 1423, Contract Data Requirements List.pdf PDF
Attachment S-5 DCAA Rate Check Form.xls XLS spreadsheet
Attachment J-5 - Janitorial Task and Frequency Chart.XLS XLS spreadsheet
Attachment S-4 - Staffing_Plan_(No_Cost).xlsx XLSX spreadsheet
Attachment J-10 - Quality Assurance Surveillance Form for CP.pdf PDF
Attachment J-17 - CO2 Fire Extinguisher and Dry Chemical Inspection Log.pdf PDF
Attachment S-1- Pricing Worksheet.xls XLS spreadsheet
N00024-17-R-4404_and_N00024-17-R-4410_QA.docx DOCX document
N00024-17-R-4404_DRAFT_STATEMENT_OF_WORK.docx DOCX document
Show all 40

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 14

Periodicity: Spec Code: Berthed At: Quarter:

NSTM 50 INSPECTION GUIDELINES Insp Date:

TDL Remarks N/A NO YES Description Item

1 Mooring lines, chains, wire ropes, and camels are adequate and properly secured? Check for signs of wear, damage and preservation.

2 Flood markers are at the waterline on the bow and stern and visible from a distance to detect a change in draft.

3 Brow is properly placed, secure and safe.

4 Topside Watertight doors, hatches and scuttles are secured from the inside or padlocked from the outside? (All doors and hatches shall be secured to allow opening from the inside in case of emergency)

5 Emergency exit(s) to vessels weather decks other than Main Access can only be opened from the inside of the ship and the route and hatch are plainly marked.

6 Classified material storage is secure?

7 Storerooms are locked and secured

8 Pilferable gear locker is locked or welded shut?

9 Ships records are properly secured?

10 Bilges, voids and open tanks are free of oil, water and trash?

11 Internal above waterline spaces are weather-tight and dry.

12 Fire hazards are removed. (Flammable materials, trash, etc.)

13 Mechanical safety devices: lifelines, safety chains at ladders, hatches and scuttles are installed and in good working order.

14 Is vessel electrically safe? Wiring safe and adequate, rubber matting properly placed in front of all energized equipment.

15 Items on PCB inventory (transformers and capacitors) inspected for leaks. No leakage observed?

16 Hazardous Material/Waste has been removed.

17 Ships exterior preservation is in good condition. Update COF as required.

18 Main Access has fire bulletin posted, fire bottles are in place and a Sign-In Log available and being utilized?

19 Is Lighting in compartments at a minimum of 50%?

20 Have all safety hazards been reported? If not list compartment / location and nature of hazard.

21 Verify condition of mooring lines and chaffing gear. Water is free of obstructions which may jeopardize the hull?

22 Air condition and refrigeration units are pumped down and isolated. Where refrigerant has been evacuated from equipment and charged with nitrogen is pressure holding? (3- 5 psig)

23 All insulating material has been sealed to prevent possible spread of asbestos?

24 All sea valves are blank flanged with valves shut tight and seizing wire is adequate to prevent opening at valve.

ARRIVAL INSPECTION

25 All Emergency Beacons have been removed from the ship?

26 Manhole screens and deck plates in place and secured properly.

27 All weather deck openings; stacks, ventilation intakes and exhaust, hatches, port holes, stuffing tubes; sealed?

28 COF items checked and updates made to the MR?

29 Record FWD, AFT Draft and ships List. Changes identified since last inspection?

30 Ships Records are properly secured in History Folders in

Building 545?

31 TAG-OUT log updated? List / Identify any unterminated cables.

32 Shaft and Rudder Locks are in place and properly mounted?

Locks are undamaged?

33 Stern tube(s) packing glands are watertight and dry (adequate packing gland available for additional adjustments)?

34 Have all other discrepancies been reported? If not report them here.

FWD Draft: AFT Draft: List:

Comments:

Inspector Inspector Inspection Manager

NSTM 50 INSPECTION GUIDELINES - Discrepancy Listing

Spec Code:

Line Item # Location Discrepancy Discovery Dt Correction Dt

File details come from the government source that posted it. Updated .