N0002414NR05201
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
See attached
1. CONTRACT ID CODE PAGE OF PAGES
1 71
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 05-Feb-2015
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N00024-15-R-5201
X 9B. DATED (SEE ITEM 11)
16-Oct-2014
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
05-Feb-2015
CODE
NAVAL SEA SYSTEMS COMMAND (HQ)
1333 ISAAC HULL AVE SE
WASHINGTON NAVY YARD DC 20376-2030
N00024 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N00024-15-R-5201
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been modified:
SF30 BLOCK 14 CONTINUATION
SECTION B - SUPPLIES OR SERVICES AND PRICES
The following have been added by full text:
NOTE I – NOTE REGARDING ENGINEERING SERVICES FEE
Applicable to Cost Plus Fixed Fee (CPFF) Contract Line Item Numbers 0009, 1009, 2009, 3009, 4009 – The Offeror shall propose no less than zero percent (0%) and no more than eight percent (8%) for fixed fee. The available fixed fee amount shall be calculated as a percentage of cost, less Facilities Capital Cost of Money.
NOTE A - The minimum quantity that shall be ordered under this Indefinite Delivery Indefinite Quantity (IDIQ) contract is four (4) units of Water Cooled CCS BTP (CLIN 0001 OR 0002) and two (2) units of Water Cooled ASAN BTP (CLIN 0003 OR 0004) as well as the associated First Article CLINs 5001 and 5003, Production Readiness Review CLIN 5014, and, if applicable, Water Cooled MCE Vendor Qualification CLIN 5010.
The purpose of amendment 0001 to the solicitation N00024-15-R-5201 was to:
1. Update Section B, NOTE E table “INCO/Spares and Repair Parts”
2. Update Section F, table “Maximum Allowable Production Lead Time INCO/Spares & Repairs”
The purpose of amendment 0002 to the solicitation N00024-15-R-5201 was to:
1. Extend the deadline for the submission of proposals to 11:00am, January 6, 2015
2. Extend the deadline for the submission of questions to close of business, November 21, 2014
3. Update Section A, Block 9
4. Update Section L.1.2
The purpose of amendment 0003 to the solicitation N00024-15-R-5201 was to incorporate the TI-16 CPS Air Cooled PS2 Requirements and make other administrative changes to Sections A through M as follows:
1. Extend the deadline for the submission of proposals to 2:00pm, 12 February 2015
2. Update Section B Line Items and the B-2-0023 clause
3. Update Section B Notes A, D, E, and H
4. Update Section C statement of work and clauses.
5. Update Section D, E, and F
6. Update Government-Furnished Property (Incorporation) for Water Cooled and Air Cooled CPS
7. Updated section I clause 52.209-3 and 52.217-7(NAVSEA VARIATION I)
8. Delete and replace Appendix A CDRLs.
9. Delete and replace Attachment J-2. Offerors are advised that this supplemental drawing package will be sent only to those Offerors who have an executed “Terms of Use” letter.
10. Delete and replace Attachment J-3
11. Update Section L
12. Extend the deadline for the submission of questions to close of business, 14 January 2015
13. Update Section M
14. Provide a conformed Solicitation through Amendment 0003
15. All other terms and conditions remain in full force and effect.
The purpose of amendment 0004 to the solicitation N00024-15-R-5201 was to make administrative changes to Sections A through M as follows:
1. Extend the deadline for the submission of proposals to 2:00pm EST, Thursday, 26 February 2015.
Note: NAVSEA contracts will have moved to the Washington Navy Yard by this due date.
2. No extension is provided for the submission of questions or requests for access to the CPS competition library.
3. Update Section C:
a. CLIN Description, to clarify PIO CLIN numbers.
b. 3.3.3 Work Instructions: to add, “Pre-production Assembly Aides for Air Cooled PS2 8601113 will be provided at Contract Award from which the Contractor shall use to create Air Cooled PS2 8601113 Work Instructions.”
c. 3.3.4, to read “However, the CPS units require Circuit Breaker Modifications be made to the standard MCE.” The sentence previously stated, “However, the CPS units have Circuit Breaker Modifications made to the standard MCE.”
4. Update Section H, Clause 5252.245-9109 GOVERNMENT-FURNISHED PROPERTY (INCORPORATION) (SEP 1990) to clarify what is provided in a Government-Furnished MCE
5. Update Section I, clauses to include clauses:
a. FAR 52.251-1 "GOVERNMENT SUPPLY SOURCES (APR 2012)",
b. 52.209-3 “FIRST ARTICLE APPROVAL--CONTRACTOR TESTING (SEP 1989) -
ALTERNATE I (JAN 1997),”
c. DFARS 252.251-7000 "ORDERING FROM GOVERNMENT SUPPLY SOURCES (AUG
2012)" and
d. FAR 52.204-19 "INCORPORATION BY REFERENCE OF REPRESENTATIONS AND
CERTIFICATIONS (DEC 2014)"
6. Update Section J Attachment J-2 to:
a. define order of precedence between TDPs and BOMs.
b. include OD32193, separate software, and missing drawing part numbers to be sent only to those
Offerors who have an executed “Terms of Use” letter.
c. include “Pre-production Assembly Aides for Air Cooled PS2 8601113 (to be provided at contract award).
7. Add Attachment J-9, “Bidder's Question & Answers Conformed” and incorporate into this solicitation
8. Update Section L to:
a. Eliminate the word “display”
b. Add Section L.6.(6) to require quotations from the qualified MCE vendor
c. Replace HQ L-2-0013 Alt I with HQ L-2-0013 SPECIAL PROPOSAL RECEIPT
REQUIREMENTS; NAVSEA will be back at the Washington Navy Yard at the proposal due date
d. Add items to the “Required Sources of Supply” List
9. Provide a conformed Solicitation through Amendment 0004
10. All other terms and conditions remain in full force and effect.
The purpose of amendment 0005 to the solicitation N00024-15-R-5201 is to make administrative changes to Sections A through M as follows:
1. Update Section B to add Note I concerning Engineering Services Fee.
2. Update Section B, Note A
3. Update Section C, to tailor NAVSEA Clause HQ C-2-0026 FIRST ARTICLE to allow delivery of FAU pending Government approval.
4. Update Section I to display DFARS clause 252.204-7012 “Safeguarding of Unclassified Controlled
Technical Information” in full text.
5. Update Section J-2 with the following:
• Addendum for Air-cooled PS2 including FAT procedures and missing drawing #s/references are provided as GFI on a single, separate disk and are incorporated as part of the CPS TDPs (Dated 29 January 2015).
• PN 8479934, CPS water-cooled cable assembly drawings and missing drawing #s/references are provided as GFI on a single, separate disk and are incorporated as part of the CPS TDPs.
• FAT System Procedure No. 7422090 Rev L, Q70 Source of Supply document No. 7999121 Rev KE, Bidder’s Q&A with controlled technical references and missing drawing #s/references are provided as GFI on a single, separate disk and are incorporated as part of the CPS TDPs (Dated 5 February 2015).
6. Provide Attachments J-7 “Compliance Checklist” and J-8 “Contract Award Announcement Information”
7. Update Attachment J-9 “Bidders’s Questions and Answers.” All Bidders' Questions have now been answered.
8. Update Section L:
a. L.1.6. “PROPOSAL PACKING INSTRUCTIONS”
b. L.3. VOLUME I – “OFFER/SIGNED SOLICITATION SET” to contain the following language: “All Firm Fixed Priced (FFP) CLINs in Volume I shall be be proposed in whole dollars only. The Offeror shall not propose pricing in Volume I for FFP CLINs in a format containing cents. In the event of a discrepancy between prices found in Volume I and Volume IV, pricing in Volume I shall utilized.”
c. L.3(2)
d. L.6. VOLUME IV – PRICE PROPOSAL (1) Bill of Materials now reads: “The Offeror shall propose a detailed Bill of Material (BOM) for CLINs 0001-0008 and, if the Offeror proposes to make, the MCE (Contained in Note E). The BOM is not required to be priced. The Offeror shall inlcude in the BOM all single items and bundles of the same item greater than $700,000. The Offeror’s BOM shall demonstrate a complete understanding of the CPS TI 16 requirements.”
9. Update Section M
a. M.1, General Information
b. M.3, Total Evaluated Price (TEP), (3) Rent-free use
c. M.4, Basis for Award
10. All Bidders' Questions have now been answered.
11. Provide a conformed Solicitation through Amendment 0005
12. All other terms and conditions remain in full force and effect.
NOTE F – The quantity of labor hours is the maximum order quantity. Labor hours for each task shall be established through negotiation in each delivery order via a Government-provided Statement of Work (SOW). Total hour ceilings shall be the only variable negotiated with each delivery order. The Estimated Cost Plus Fixed Fee (CPFF) amount provided in each delivery order shall be established unilaterally using the composite Rate per Hour proposed in the table below. (Offeror to fill in)
CLIN 0009 1009 2009 3009 4009
Est. Cost / Hour $ $ $ $ $ Est. Fixed Fee / Hour $ $ $ $ $
Unit Price / Hour $ $ $ $ $
The quantity of hours does not indicate that the Government will necessarily require this amount or any at all. Any travel, incidental material consumed, other direct costs (ODCs) and/or subcontractor effort associated with the performance of this effort shall be included in the proposed man-hour rate.
NOTE E – Stepladder pricing for CLINs 0011, 1011, 2011, 3011 and 4011 is as established in table below. The Section B Firm Fixed Price (FFP) amount and the funding provided in each delivery order shall be unilaterally established based on the stepladder pricing in the table below. Every thirty (30) days beginning upon contract award, the Government shall review all orders placed within that timeframe to determine the final unit price. The final unit price shall be based on the total number of parts required for spares/INCO and CPS production orders placed within that 30 day timeframe. The Government will retain the unilateral right to amend issued delivery orders at the final unit price.
Note E: CPS TI 16 Step-Ladder Line Items - Unit Price INCO/Spares and Repair Parts BASE YEAR - CLIN 0011
Description Part Number Qty 1-4 Qty 5-9 Qty 10+ REPAIRS Enclosure Monitor Electronics 'Room Alert32e-TH1-RAS' $ $ $ $ DC Power Supply 'PYB15-Q24-S5-U' $ $ $ $ Remote Access Server 'IOLAN SCS32' $ $ $ $ ATCA Chassis Centellis 4440 AXP 1440-C03 $ $ $ $ Fan Module Upper UFT-1440 - Artesyn Embedded Technologies $ $ $ $ Fan Module Lower LFT-1440 - Artesyn Embedded Technologies $ $ $ $ Power Entry Module PEM1620 - Artesyn Embedded Technologies $ $ $ $ Shelf Managers SAM1411 - Artesyn Embedded Technologies $ $ $ $
HDD ATCA-7XMMOD-SATA2 $ $ $ $
Switch Blade ATCA F140 $ $ $ $ Switch RTM RTM-ATCA-F140 $ $ $ $ 40GB QSFP+ Transceiver QSFP-40GE-LR4= $ $ $ $ 10G (LR) SFP+ Transceiver SFP-10G-LR $ $ $ $ 1G SFP Copper Transceiver GLC-T $ $ $ $ 1G (LX) SFP Transceiver GLC-LH-SMD= $ $ $ $ 1G (SX) SFP Transceiver GLC-SX-MMD= $ $ $ $ ATCA-7480 Server Blade ATCA-7480-0GB $ $ $ $ DC Power Distribution APS3-421-A0A $ $ $ $ Controller SC-200 $ $ $ $ Rectifier Modules AP48-ES $ $ $ $ Mission Critical Enclosure (MCE) 7420700-107 (8479974) $ $ $ $ 1G SFP Copper Transceiver GLC-T $ $ $ $ IP Controlled Power 'IPC3401-Net' $ $ $ $ Edge Switch Cisco 3064 'N3K-C3064-X-BA-L3' $ $ $ $ Cisco 3064 Dual Power Supplies 'N2200-PAC-400W-B' $ $ $ $ Cisco 3064 Fan Assembly 'N3K-C3064-FAN-B' $ $ $ $ 40GB QSFP+ Transceiver 'QSFP-40GE-LR4=' $ $ $ $ 10G (LR) SFP+ Transceiver 'SFP-10G-LR' $ $ $ $ 10G (SR) SFP+ Transceiver 'SFP-10G-SR' $ $ $ $ 1G (LX) SFP Transceiver 'GLC-LH-SMD=' $ $ $ $ 1G (SX) SFP Transceiver 'GLC-SX-MMD=' $ $ $ $ Storage Controller D3420XA28810DA $ $ $ $ Power Supply 7001540J000 (Emerson) $ $ $ $ Controller Module FRUKC23-01B (Dot Hill) $ $ $ $ Disks PFRUKTXSXN129-24 $ $ $ $ 10GbE Network Interface Card PE310G4SPI9LA-E-XR 10G PCI $ $ $ $ Storage Expansion D3120XA28810DA $ $ $ $
NAS 535-100052-11814 $ $ $ $
Description Part Number Qty 1-4 Qty 5-9 Qty 10+ REPAIRS
SHELF MANAGEMENT ALARM
MODULE, ATCA
SAM1620 $ $ $ $
POWER ENTRY MODULE, ATCA PEM1620 $ $ $ $
UPPER FAN TRAY MODULE, ATCA UFT-1440 $ $ $ $
LOWER FAN TRAY MODULE, ATCA LFT-1440 $ $ $ $
PROCESSOR BLADE, ATCA ATCA-7480-0GB $ $ $ $
SATA DISK DRIVE, ATCA ATCA-7XMMOD SATA 3 $ $ $ $
ATCA-7480 RAM ATCA-7XMEM-2133-8G $ $ $ $
SWITCH BLADE, ATCA ATCA-F140 $ $ $ $
SWITCH, ETHERNET N3K-C3064-E-BD-L3 $ $ $ $
40GB QSFP+ TRANSCEIVER QSFP-40GE-LR4= $ $ $ $
10G (LR) SFP+ TRANSCEIVER SFP-10G-LR $ $ $ $
10G (SR) SFP+ TRANSCEIVER SFP-10G-SR $ $ $ $
1G (LX) SFP TRANSCEIVER GLC-LH-SMD= $ $ $ $
1G (SX) SFP TRANSCEIVER GLC-SX-MMD= $ $ $ $
1G COPPER, SFP, 1000BASE-T GLC-T= $ $ $ $
POWER SUPPLY, 3U RM6-320-4301 $ $ $ $
48 VDC RECTIFIER MODULE APR48-ES $ $ $ $
ROOM ALERT MONITOR ROOM ALERT32E-TH1-RAS $ $ $ $
RAS IOLAN SCS 32 DC 04030270 $ $ $ $
1U SERVER 531-100049-12273 $ $ $ $
CONTROLLER MODULE FRUKC23-01B $ $ $ $
POWER SUPPLY, SAN 7001540J000 $ $ $ $
2.5" SAS DISK, SAN PFRUKTXSXN129-01 $ $ $ $
PANEL, TOUCH TS-TPC-8900-4710 $ $ $ $
BATTERY TEL-30 $ $ $ $
DC CONTACTOR GX12-CCB $ $ $ $
ASSEMBLY, FAN, 48V 8601113-807 $ $ $ $
ETHERNET SWITCH, 5-PORT
UNMANAGED GIGABIT
SLX-5EG-1 $ $ $ $
SHELF MANAGEMENT ALARM
MODULE, ATCA
8601113-279 $ $ $ $
POWER ENTRY MODULE, ATCA 8601113-280 $ $ $ $
UPPER FAN TRAY MODULE, ATCA 8601113-281 $ $ $ $
LOWER FAN TRAY MODULE, ATCA 8601113-282 $ $ $ $
PROCESSOR BLADE, ATCA 8479963 $ $ $ $
SATA DISK DRIVE, ATCA 8479964 $ $ $ $
ATCA-7480 RAM 8601113-284 $ $ $ $
SWITCH BLADE, ATCA 8479962 $ $ $ $
SWITCH, ETHERNET 8601113-297 $ $ $ $
40GB QSFP+ TRANSCEIVER 8479943 $ $ $ $
10G (LR) SFP+ TRANSCEIVER 8479944-001 $ $ $ $
10G (SR) SFP+ TRANSCEIVER 8479944-002 $ $ $ $
1G (LX) SFP TRANSCEIVER 8479944-003 $ $ $ $
1G (SX) SFP TRANSCEIVER 8479944-004 $ $ $ $
1G COPPER, SFP, 1000BASE-T 8479944-006 $ $ $ $
POWER SUPPLY, 3U 8601113-286 $ $ $ $
48 VDC RECTIFIER MODULE 8601113-288 $ $ $ $
ROOM ALERT MONITOR 8479878 $ $ $ $
RAS IOLAN SCS 32 DC 8601113-298 $ $ $ $
1U SERVER 8601113-299 $ $ $ $
CONTROLLER MODULE 8601113-290 $ $ $ $
POWER SUPPLY, SAN 8601113-291 $ $ $ $
2.5" SAS DISK, SAN 8601113-292 $ $ $ $
PANEL, TOUCH 8601113-811 $ $ $ $
Description Part Number Qty 1-4 Qty 5-9 Qty 10+ REPAIRS
BATTERY TEL-30 $ $ $ $
DC CONTACTOR GX12-CCB $ $ $ $
ASSEMBLY, FAN, 48V 8601113-807 $ $ $ $
ETHERNET SWITCH, 5-PORT
UNMANAGED GIGABIT
8601113-289 $ $ $ $
INCO/Spares and Repair Parts Option Year 1 - CLIN 1011
Description Part Number Qty 1-4 Qty 5-9 Qty 10+ REPAIRS Enclosure Monitor Electronics 'Room Alert32e-TH1-RAS' $ $ $ $ DC Power Supply 'PYB15-Q24-S5-U' $ $ $ $ Remote Access Server 'IOLAN SCS32' $ $ $ $ ATCA Chassis Centellis 4440 AXP 1440-C03 $ $ $ $ Fan Module Upper UFT-1440 - Artesyn Embedded Technologies $ $ $ $ Fan Module Lower LFT-1440 - Artesyn Embedded Technologies $ $ $ $ Power Entry Module PEM1620 - Artesyn Embedded Technologies $ $ $ $ Shelf Managers SAM1411 - Artesyn Embedded Technologies $ $ $ $
HDD ATCA-7XMMOD-SATA2 $ $ $ $
Switch Blade ATCA F140 $ $ $ $ Switch RTM RTM-ATCA-F140 $ $ $ $ 40GB QSFP+ Transceiver QSFP-40GE-LR4= $ $ $ $ 10G (LR) SFP+ Transceiver SFP-10G-LR $ $ $ $ 1G SFP Copper Transceiver GLC-T $ $ $ $ 1G (LX) SFP Transceiver GLC-LH-SMD= $ $ $ $ 1G (SX) SFP Transceiver GLC-SX-MMD= $ $ $ $ ATCA-7480 Server Blade ATCA-7480-0GB $ $ $ $ DC Power Distribution APS3-421-A0A $ $ $ $ Controller SC-200 $ $ $ $ Rectifier Modules AP48-ES $ $ $ $ Mission Critical Enclosure (MCE) 7420700-107 (8479974) $ $ $ $ 1G SFP Copper Transceiver GLC-T $ $ $ $ IP Controlled Power 'IPC3401-Net' $ $ $ $ Edge Switch Cisco 3064 'N3K-C3064-X-BA-L3' $ $ $ $ Cisco 3064 Dual Power Supplies 'N2200-PAC-400W-B' $ $ $ $ Cisco 3064 Fan Assembly 'N3K-C3064-FAN-B' $ $ $ $ 40GB QSFP+ Transceiver 'QSFP-40GE-LR4=' $ $ $ $ 10G (LR) SFP+ Transceiver 'SFP-10G-LR' $ $ $ $ 10G (SR) SFP+ Transceiver 'SFP-10G-SR' $ $ $ $ 1G (LX) SFP Transceiver 'GLC-LH-SMD=' $ $ $ $ 1G (SX) SFP Transceiver 'GLC-SX-MMD=' $ $ $ $ Storage Controller D3420XA28810DA $ $ $ $ Power Supply 7001540J000 (Emerson) $ $ $ $ Controller Module FRUKC23-01B (Dot Hill) $ $ $ $ Disks PFRUKTXSXN129-24 $ $ $ $ 10GbE Network Interface Card PE310G4SPI9LA-E-XR 10G PCI $ $ $ $ Storage Expansion D3120XA28810DA $ $ $ $
NAS 535-100052-11814 $ $ $ $
SHELF MANAGEMENT ALARM SAM1620 $ $ $ $
Description Part Number Qty 1-4 Qty 5-9 Qty 10+ REPAIRS
MODULE, ATCA
POWER ENTRY MODULE, ATCA PEM1620 $ $ $ $
UPPER FAN TRAY MODULE, ATCA UFT-1440 $ $ $ $
LOWER FAN TRAY MODULE, ATCA LFT-1440 $ $ $ $
PROCESSOR BLADE, ATCA ATCA-7480-0GB $ $ $ $
SATA DISK DRIVE, ATCA ATCA-7XMMOD SATA 3 $ $ $ $
ATCA-7480 RAM ATCA-7XMEM-2133-8G $ $ $ $
SWITCH BLADE, ATCA ATCA-F140 $ $ $ $
SWITCH, ETHERNET N3K-C3064-E-BD-L3 $ $ $ $
40GB QSFP+ TRANSCEIVER QSFP-40GE-LR4= $ $ $ $
10G (LR) SFP+ TRANSCEIVER SFP-10G-LR $ $ $ $
10G (SR) SFP+ TRANSCEIVER SFP-10G-SR $ $ $ $
1G (LX) SFP TRANSCEIVER GLC-LH-SMD= $ $ $ $
1G (SX) SFP TRANSCEIVER GLC-SX-MMD= $ $ $ $
1G COPPER, SFP, 1000BASE-T GLC-T= $ $ $ $
POWER SUPPLY, 3U RM6-320-4301 $ $ $ $
48 VDC RECTIFIER MODULE APR48-ES $ $ $ $
ROOM ALERT MONITOR ROOM ALERT32E-TH1-RAS $ $ $ $
RAS IOLAN SCS 32 DC 04030270 $ $ $ $
1U SERVER 531-100049-12273 $ $ $ $
CONTROLLER MODULE FRUKC23-01B $ $ $ $
POWER SUPPLY, SAN 7001540J000 $ $ $ $
2.5" SAS DISK, SAN PFRUKTXSXN129-01 $ $ $ $
PANEL, TOUCH TS-TPC-8900-4710 $ $ $ $
BATTERY TEL-30 $ $ $ $
DC CONTACTOR GX12-CCB $ $ $ $
ASSEMBLY, FAN, 48V 8601113-807 $ $ $ $
ETHERNET SWITCH, 5-PORT
UNMANAGED GIGABIT
SLX-5EG-1 $ $ $ $
SHELF MANAGEMENT ALARM
MODULE, ATCA
8601113-279 $ $ $ $
POWER ENTRY MODULE, ATCA 8601113-280 $ $ $ $
UPPER FAN TRAY MODULE, ATCA 8601113-281 $ $ $ $
LOWER FAN TRAY MODULE, ATCA 8601113-282 $ $ $ $
PROCESSOR BLADE, ATCA 8479963 $ $ $ $
SATA DISK DRIVE, ATCA 8479964 $ $ $ $
ATCA-7480 RAM 8601113-284 $ $ $ $
SWITCH BLADE, ATCA 8479962 $ $ $ $
SWITCH, ETHERNET 8601113-297 $ $ $ $
40GB QSFP+ TRANSCEIVER 8479943 $ $ $ $
10G (LR) SFP+ TRANSCEIVER 8479944-001 $ $ $ $
10G (SR) SFP+ TRANSCEIVER 8479944-002 $ $ $ $
1G (LX) SFP TRANSCEIVER 8479944-003 $ $ $ $
1G (SX) SFP TRANSCEIVER 8479944-004 $ $ $ $
1G COPPER, SFP, 1000BASE-T 8479944-006 $ $ $ $
POWER SUPPLY, 3U 8601113-286 $ $ $ $
48 VDC RECTIFIER MODULE 8601113-288 $ $ $ $
ROOM ALERT MONITOR 8479878 $ $ $ $
RAS IOLAN SCS 32 DC 8601113-298 $ $ $ $
1U SERVER 8601113-299 $ $ $ $
CONTROLLER MODULE 8601113-290 $ $ $ $
POWER SUPPLY, SAN 8601113-291 $ $ $ $
2.5" SAS DISK, SAN 8601113-292 $ $ $ $
PANEL, TOUCH 8601113-811 $ $ $ $
BATTERY TEL-30 $ $ $ $
DC CONTACTOR GX12-CCB $ $ $ $
Description Part Number Qty 1-4 Qty 5-9 Qty 10+ REPAIRS
ASSEMBLY, FAN, 48V 8601113-807 $ $ $ $
ETHERNET SWITCH, 5-PORT
INCO/Spares and Repair Parts Option Year 2 - CLIN 2011
Description Part Number Qty 1-4 Qty 5-9 Qty 10+ REPAIRS Enclosure Monitor Electronics 'Room Alert32e-TH1-RAS' $ $ $ $ DC Power Supply 'PYB15-Q24-S5-U' $ $ $ $ Remote Access Server 'IOLAN SCS32' $ $ $ $ ATCA Chassis Centellis 4440 AXP 1440-C03 $ $ $ $ Fan Module Upper UFT-1440 - Artesyn Embedded Technologies $ $ $ $ Fan Module Lower LFT-1440 - Artesyn Embedded Technologies $ $ $ $ Power Entry Module PEM1620 - Artesyn Embedded Technologies $ $ $ $ Shelf Managers SAM1411 - Artesyn Embedded Technologies $ $ $ $
HDD ATCA-7XMMOD-SATA2 $ $ $ $
Switch Blade ATCA F140 $ $ $ $ Switch RTM RTM-ATCA-F140 $ $ $ $ 40GB QSFP+ Transceiver QSFP-40GE-LR4= $ $ $ $ 10G (LR) SFP+ Transceiver SFP-10G-LR $ $ $ $ 1G SFP Copper Transceiver GLC-T $ $ $ $ 1G (LX) SFP Transceiver GLC-LH-SMD= $ $ $ $ 1G (SX) SFP Transceiver GLC-SX-MMD= $ $ $ $ ATCA-7480 Server Blade ATCA-7480-0GB $ $ $ $ DC Power Distribution APS3-421-A0A $ $ $ $ Controller SC-200 $ $ $ $ Rectifier Modules AP48-ES $ $ $ $ Mission Critical Enclosure (MCE) 7420700-107 (8479974) $ $ $ $ 1G SFP Copper Transceiver GLC-T $ $ $ $ IP Controlled Power 'IPC3401-Net' $ $ $ $ Edge Switch Cisco 3064 'N3K-C3064-X-BA-L3' $ $ $ $ Cisco 3064 Dual Power Supplies 'N2200-PAC-400W-B' $ $ $ $ Cisco 3064 Fan Assembly 'N3K-C3064-FAN-B' $ $ $ $ 40GB QSFP+ Transceiver 'QSFP-40GE-LR4=' $ $ $ $ 10G (LR) SFP+ Transceiver 'SFP-10G-LR' $ $ $ $ 10G (SR) SFP+ Transceiver 'SFP-10G-SR' $ $ $ $ 1G (LX) SFP Transceiver 'GLC-LH-SMD=' $ $ $ $ 1G (SX) SFP Transceiver 'GLC-SX-MMD=' $ $ $ $ Storage Controller D3420XA28810DA $ $ $ $ Power Supply 7001540J000 (Emerson) $ $ $ $ Controller Module FRUKC23-01B (Dot Hill) $ $ $ $ Disks PFRUKTXSXN129-24 $ $ $ $ 10GbE Network Interface Card PE310G4SPI9LA-E-XR 10G PCI $ $ $ $ Storage Expansion D3120XA28810DA $ $ $ $
NAS 535-100052-11814 $ $ $ $
SHELF MANAGEMENT ALARM
MODULE, ATCA
SAM1620 $ $ $ $
POWER ENTRY MODULE, ATCA PEM1620 $ $ $ $
Description Part Number Qty 1-4 Qty 5-9 Qty 10+ REPAIRS
UPPER FAN TRAY MODULE, ATCA UFT-1440 $ $ $ $
LOWER FAN TRAY MODULE, ATCA LFT-1440 $ $ $ $
PROCESSOR BLADE, ATCA ATCA-7480-0GB $ $ $ $
SATA DISK DRIVE, ATCA ATCA-7XMMOD SATA 3 $ $ $ $
ATCA-7480 RAM ATCA-7XMEM-2133-8G $ $ $ $
SWITCH BLADE, ATCA ATCA-F140 $ $ $ $
SWITCH, ETHERNET N3K-C3064-E-BD-L3 $ $ $ $
40GB QSFP+ TRANSCEIVER QSFP-40GE-LR4= $ $ $ $
10G (LR) SFP+ TRANSCEIVER SFP-10G-LR $ $ $ $
10G (SR) SFP+ TRANSCEIVER SFP-10G-SR $ $ $ $
1G (LX) SFP TRANSCEIVER GLC-LH-SMD= $ $ $ $
1G (SX) SFP TRANSCEIVER GLC-SX-MMD= $ $ $ $
1G COPPER, SFP, 1000BASE-T GLC-T= $ $ $ $
POWER SUPPLY, 3U RM6-320-4301 $ $ $ $
48 VDC RECTIFIER MODULE APR48-ES $ $ $ $
ROOM ALERT MONITOR ROOM ALERT32E-TH1-RAS $ $ $ $
RAS IOLAN SCS 32 DC 04030270 $ $ $ $
1U SERVER 531-100049-12273 $ $ $ $
CONTROLLER MODULE FRUKC23-01B $ $ $ $
POWER SUPPLY, SAN 7001540J000 $ $ $ $
2.5" SAS DISK, SAN PFRUKTXSXN129-01 $ $ $ $
PANEL, TOUCH TS-TPC-8900-4710 $ $ $ $
BATTERY TEL-30 $ $ $ $
DC CONTACTOR GX12-CCB $ $ $ $
ASSEMBLY, FAN, 48V 8601113-807 $ $ $ $
ETHERNET SWITCH, 5-PORT
UNMANAGED GIGABIT
SLX-5EG-1 $ $ $ $
SHELF MANAGEMENT ALARM
MODULE, ATCA
8601113-279 $ $ $ $
POWER ENTRY MODULE, ATCA 8601113-280 $ $ $ $
UPPER FAN TRAY MODULE, ATCA 8601113-281 $ $ $ $
LOWER FAN TRAY MODULE, ATCA 8601113-282 $ $ $ $
PROCESSOR BLADE, ATCA 8479963 $ $ $ $
SATA DISK DRIVE, ATCA 8479964 $ $ $ $
ATCA-7480 RAM 8601113-284 $ $ $ $
SWITCH BLADE, ATCA 8479962 $ $ $ $
SWITCH, ETHERNET 8601113-297 $ $ $ $
40GB QSFP+ TRANSCEIVER 8479943 $ $ $ $
10G (LR) SFP+ TRANSCEIVER 8479944-001 $ $ $ $
10G (SR) SFP+ TRANSCEIVER 8479944-002 $ $ $ $
1G (LX) SFP TRANSCEIVER 8479944-003 $ $ $ $
1G (SX) SFP TRANSCEIVER 8479944-004 $ $ $ $
1G COPPER, SFP, 1000BASE-T 8479944-006 $ $ $ $
POWER SUPPLY, 3U 8601113-286 $ $ $ $
48 VDC RECTIFIER MODULE 8601113-288 $ $ $ $
ROOM ALERT MONITOR 8479878 $ $ $ $
RAS IOLAN SCS 32 DC 8601113-298 $ $ $ $
1U SERVER 8601113-299 $ $ $ $
CONTROLLER MODULE 8601113-290 $ $ $ $
POWER SUPPLY, SAN 8601113-291 $ $ $ $
2.5" SAS DISK, SAN 8601113-292 $ $ $ $
PANEL, TOUCH 8601113-811 $ $ $ $
BATTERY TEL-30 $ $ $ $
DC CONTACTOR GX12-CCB $ $ $ $
ASSEMBLY, FAN, 48V 8601113-807 $ $ $ $
ETHERNET SWITCH, 5-PORT 8601113-289 $ $ $ $
Description Part Number Qty 1-4 Qty 5-9 Qty 10+ REPAIRS
INCO/Spares and Repair Parts Option Year 3- CLIN 3011
Description Part Number Qty 1-4 Qty 5-9 Qty 10+ REPAIRS Enclosure Monitor Electronics 'Room Alert32e-TH1-RAS' $ $ $ $ DC Power Supply 'PYB15-Q24-S5-U' $ $ $ $ Remote Access Server 'IOLAN SCS32' $ $ $ $ ATCA Chassis Centellis 4440 AXP 1440-C03 $ $ $ $ Fan Module Upper UFT-1440 - Artesyn Embedded Technologies $ $ $ $ Fan Module Lower LFT-1440 - Artesyn Embedded Technologies $ $ $ $ Power Entry Module PEM1620 - Artesyn Embedded Technologies $ $ $ $ Shelf Managers SAM1411 - Artesyn Embedded Technologies $ $ $ $
HDD ATCA-7XMMOD-SATA2 $ $ $ $
Switch Blade ATCA F140 $ $ $ $ Switch RTM RTM-ATCA-F140 $ $ $ $ 40GB QSFP+ Transceiver QSFP-40GE-LR4= $ $ $ $ 10G (LR) SFP+ Transceiver SFP-10G-LR $ $ $ $ 1G SFP Copper Transceiver GLC-T $ $ $ $ 1G (LX) SFP Transceiver GLC-LH-SMD= $ $ $ $ 1G (SX) SFP Transceiver GLC-SX-MMD= $ $ $ $ ATCA-7480 Server Blade ATCA-7480-0GB $ $ $ $ DC Power Distribution APS3-421-A0A $ $ $ $ Controller SC-200 $ $ $ $ Rectifier Modules AP48-ES $ $ $ $ Mission Critical Enclosure (MCE) 7420700-107 (8479974) $ $ $ $ 1G SFP Copper Transceiver GLC-T $ $ $ $ IP Controlled Power 'IPC3401-Net' $ $ $ $ Edge Switch Cisco 3064 'N3K-C3064-X-BA-L3' $ $ $ $ Cisco 3064 Dual Power Supplies 'N2200-PAC-400W-B' $ $ $ $ Cisco 3064 Fan Assembly 'N3K-C3064-FAN-B' $ $ $ $ 40GB QSFP+ Transceiver 'QSFP-40GE-LR4=' $ $ $ $ 10G (LR) SFP+ Transceiver 'SFP-10G-LR' $ $ $ $ 10G (SR) SFP+ Transceiver 'SFP-10G-SR' $ $ $ $ 1G (LX) SFP Transceiver 'GLC-LH-SMD=' $ $ $ $ 1G (SX) SFP Transceiver 'GLC-SX-MMD=' $ $ $ $ Storage Controller D3420XA28810DA $ $ $ $ Power Supply 7001540J000 (Emerson) $ $ $ $ Controller Module FRUKC23-01B (Dot Hill) $ $ $ $ Disks PFRUKTXSXN129-24 $ $ $ $ 10GbE Network Interface Card PE310G4SPI9LA-E-XR 10G PCI $ $ $ $ Storage Expansion D3120XA28810DA $ $ $ $
NAS 535-100052-11814 $ $ $ $
SHELF MANAGEMENT ALARM
MODULE, ATCA
SAM1620 $ $ $ $
POWER ENTRY MODULE, ATCA PEM1620 $ $ $ $
UPPER FAN TRAY MODULE, ATCA UFT-1440 $ $ $ $
LOWER FAN TRAY MODULE, ATCA LFT-1440 $ $ $ $
INCO/Spares and Repair Parts Option Year 3- CLIN 3011
Description Part Number Qty 1-4 Qty 5-9 Qty 10+ REPAIRS
PROCESSOR BLADE, ATCA ATCA-7480-0GB $ $ $ $
SATA DISK DRIVE, ATCA ATCA-7XMMOD SATA 3 $ $ $ $
ATCA-7480 RAM ATCA-7XMEM-2133-8G $ $ $ $
SWITCH BLADE, ATCA ATCA-F140 $ $ $ $
SWITCH, ETHERNET N3K-C3064-E-BD-L3 $ $ $ $
40GB QSFP+ TRANSCEIVER QSFP-40GE-LR4= $ $ $ $
10G (LR) SFP+ TRANSCEIVER SFP-10G-LR $ $ $ $
10G (SR) SFP+ TRANSCEIVER SFP-10G-SR $ $ $ $
1G (LX) SFP TRANSCEIVER GLC-LH-SMD= $ $ $ $
1G (SX) SFP TRANSCEIVER GLC-SX-MMD= $ $ $ $
1G COPPER, SFP, 1000BASE-T GLC-T= $ $ $ $
POWER SUPPLY, 3U RM6-320-4301 $ $ $ $
48 VDC RECTIFIER MODULE APR48-ES $ $ $ $
ROOM ALERT MONITOR ROOM ALERT32E-TH1-RAS $ $ $ $
RAS IOLAN SCS 32 DC 04030270 $ $ $ $
1U SERVER 531-100049-12273 $ $ $ $
CONTROLLER MODULE FRUKC23-01B $ $ $ $
POWER SUPPLY, SAN 7001540J000 $ $ $ $
2.5" SAS DISK, SAN PFRUKTXSXN129-01 $ $ $ $
PANEL, TOUCH TS-TPC-8900-4710 $ $ $ $
BATTERY TEL-30 $ $ $ $
DC CONTACTOR GX12-CCB $ $ $ $
ASSEMBLY, FAN, 48V 8601113-807 $ $ $ $
ETHERNET SWITCH, 5-PORT
UNMANAGED GIGABIT
SLX-5EG-1 $ $ $ $
SHELF MANAGEMENT ALARM
MODULE, ATCA
8601113-279 $ $ $ $
POWER ENTRY MODULE, ATCA 8601113-280 $ $ $ $
UPPER FAN TRAY MODULE, ATCA 8601113-281 $ $ $ $
LOWER FAN TRAY MODULE, ATCA 8601113-282 $ $ $ $
PROCESSOR BLADE, ATCA 8479963 $ $ $ $
SATA DISK DRIVE, ATCA 8479964 $ $ $ $
ATCA-7480 RAM 8601113-284 $ $ $ $
SWITCH BLADE, ATCA 8479962 $ $ $ $
SWITCH, ETHERNET 8601113-297 $ $ $ $
40GB QSFP+ TRANSCEIVER 8479943 $ $ $ $
10G (LR) SFP+ TRANSCEIVER 8479944-001 $ $ $ $
10G (SR) SFP+ TRANSCEIVER 8479944-002 $ $ $ $
1G (LX) SFP TRANSCEIVER 8479944-003 $ $ $ $
1G (SX) SFP TRANSCEIVER 8479944-004 $ $ $ $
1G COPPER, SFP, 1000BASE-T 8479944-006 $ $ $ $
POWER SUPPLY, 3U 8601113-286 $ $ $ $
48 VDC RECTIFIER MODULE 8601113-288 $ $ $ $
ROOM ALERT MONITOR 8479878 $ $ $ $
RAS IOLAN SCS 32 DC 8601113-298 $ $ $ $
1U SERVER 8601113-299 $ $ $ $
CONTROLLER MODULE 8601113-290 $ $ $ $
POWER SUPPLY, SAN 8601113-291 $ $ $ $
2.5" SAS DISK, SAN 8601113-292 $ $ $ $
PANEL, TOUCH 8601113-811 $ $ $ $
BATTERY TEL-30 $ $ $ $
DC CONTACTOR GX12-CCB $ $ $ $
ASSEMBLY, FAN, 48V 8601113-807 $ $ $ $
ETHERNET SWITCH, 5-PORT
INCO/Spares and Repair Parts Option Year 4- CLIN 4011
Description Part Number Qty 1-4 Qty 5-9 Qty 10+ REPAIRS Enclosure Monitor Electronics 'Room Alert32e-TH1-RAS' $ $ $ $ DC Power Supply 'PYB15-Q24-S5-U' $ $ $ $ Remote Access Server 'IOLAN SCS32' $ $ $ $ ATCA Chassis Centellis 4440 AXP 1440-C03 $ $ $ $ Fan Module Upper UFT-1440 - Artesyn Embedded Technologies $ $ $ $ Fan Module Lower LFT-1440 - Artesyn Embedded Technologies $ $ $ $ Power Entry Module PEM1620 - Artesyn Embedded Technologies $ $ $ $ Shelf Managers SAM1411 - Artesyn Embedded Technologies $ $ $ $
HDD ATCA-7XMMOD-SATA2 $ $ $ $
Switch Blade ATCA F140 $ $ $ $ Switch RTM RTM-ATCA-F140 $ $ $ $ 40GB QSFP+ Transceiver QSFP-40GE-LR4= $ $ $ $ 10G (LR) SFP+ Transceiver SFP-10G-LR $ $ $ $ 1G SFP Copper Transceiver GLC-T $ $ $ $ 1G (LX) SFP Transceiver GLC-LH-SMD= $ $ $ $ 1G (SX) SFP Transceiver GLC-SX-MMD= $ $ $ $ ATCA-7480 Server Blade ATCA-7480-0GB $ $ $ $ DC Power Distribution APS3-421-A0A $ $ $ $ Controller SC-200 $ $ $ $ Rectifier Modules AP48-ES $ $ $ $ Mission Critical Enclosure (MCE) 7420700-107 (8479974) $ $ $ $ 1G SFP Copper Transceiver GLC-T $ $ $ $ IP Controlled Power 'IPC3401-Net' $ $ $ $ Edge Switch Cisco 3064 'N3K-C3064-X-BA-L3' $ $ $ $ Cisco 3064 Dual Power Supplies 'N2200-PAC-400W-B' $ $ $ $ Cisco 3064 Fan Assembly 'N3K-C3064-FAN-B' $ $ $ $ 40GB QSFP+ Transceiver 'QSFP-40GE-LR4=' $ $ $ $ 10G (LR) SFP+ Transceiver 'SFP-10G-LR' $ $ $ $ 10G (SR) SFP+ Transceiver 'SFP-10G-SR' $ $ $ $ 1G (LX) SFP Transceiver 'GLC-LH-SMD=' $ $ $ $ 1G (SX) SFP Transceiver 'GLC-SX-MMD=' $ $ $ $ Storage Controller D3420XA28810DA $ $ $ $ Power Supply 7001540J000 (Emerson) $ $ $ $ Controller Module FRUKC23-01B (Dot Hill) $ $ $ $ Disks PFRUKTXSXN129-24 $ $ $ $ 10GbE Network Interface Card PE310G4SPI9LA-E-XR 10G PCI $ $ $ $ Storage Expansion D3120XA28810DA $ $ $ $
NAS 535-100052-11814 $ $ $ $
SHELF MANAGEMENT ALARM
MODULE, ATCA
SAM1620 $ $ $ $
POWER ENTRY MODULE, ATCA PEM1620 $ $ $ $
UPPER FAN TRAY MODULE, ATCA UFT-1440 $ $ $ $
LOWER FAN TRAY MODULE, ATCA LFT-1440 $ $ $ $
PROCESSOR BLADE, ATCA ATCA-7480-0GB $ $ $ $
SATA DISK DRIVE, ATCA ATCA-7XMMOD SATA 3 $ $ $ $
ATCA-7480 RAM ATCA-7XMEM-2133-8G $ $ $ $
SWITCH BLADE, ATCA ATCA-F140 $ $ $ $
SWITCH, ETHERNET N3K-C3064-E-BD-L3 $ $ $ $
40GB QSFP+ TRANSCEIVER QSFP-40GE-LR4= $ $ $ $
INCO/Spares and Repair Parts Option Year 4- CLIN 4011
Description Part Number Qty 1-4 Qty 5-9 Qty 10+ REPAIRS
10G (LR) SFP+ TRANSCEIVER SFP-10G-LR $ $ $ $
10G (SR) SFP+ TRANSCEIVER SFP-10G-SR $ $ $ $
1G (LX) SFP TRANSCEIVER GLC-LH-SMD= $ $ $ $
1G (SX) SFP TRANSCEIVER GLC-SX-MMD= $ $ $ $
1G COPPER, SFP, 1000BASE-T GLC-T= $ $ $ $
POWER SUPPLY, 3U RM6-320-4301 $ $ $ $
48 VDC RECTIFIER MODULE APR48-ES $ $ $ $
ROOM ALERT MONITOR ROOM ALERT32E-TH1-RAS $ $ $ $
RAS IOLAN SCS 32 DC 04030270 $ $ $ $
1U SERVER 531-100049-12273 $ $ $ $
CONTROLLER MODULE FRUKC23-01B $ $ $ $
POWER SUPPLY, SAN 7001540J000 $ $ $ $
2.5" SAS DISK, SAN PFRUKTXSXN129-01 $ $ $ $
PANEL, TOUCH TS-TPC-8900-4710 $ $ $ $
BATTERY TEL-30 $ $ $ $
DC CONTACTOR GX12-CCB $ $ $ $
ASSEMBLY, FAN, 48V 8601113-807 $ $ $ $
ETHERNET SWITCH, 5-PORT
UNMANAGED GIGABIT
SLX-5EG-1 $ $ $ $
SHELF MANAGEMENT ALARM
MODULE, ATCA
8601113-279 $ $ $ $
POWER ENTRY MODULE, ATCA 8601113-280 $ $ $ $
UPPER FAN TRAY MODULE, ATCA 8601113-281 $ $ $ $
LOWER FAN TRAY MODULE, ATCA 8601113-282 $ $ $ $
PROCESSOR BLADE, ATCA 8479963 $ $ $ $
SATA DISK DRIVE, ATCA 8479964 $ $ $ $
ATCA-7480 RAM 8601113-284 $ $ $ $
SWITCH BLADE, ATCA 8479962 $ $ $ $
SWITCH, ETHERNET 8601113-297 $ $ $ $
40GB QSFP+ TRANSCEIVER 8479943 $ $ $ $
10G (LR) SFP+ TRANSCEIVER 8479944-001 $ $ $ $
10G (SR) SFP+ TRANSCEIVER 8479944-002 $ $ $ $
1G (LX) SFP TRANSCEIVER 8479944-003 $ $ $ $
1G (SX) SFP TRANSCEIVER 8479944-004 $ $ $ $
1G COPPER, SFP, 1000BASE-T 8479944-006 $ $ $ $
POWER SUPPLY, 3U 8601113-286 $ $ $ $
48 VDC RECTIFIER MODULE 8601113-288 $ $ $ $
ROOM ALERT MONITOR 8479878 $ $ $ $
RAS IOLAN SCS 32 DC 8601113-298 $ $ $ $
1U SERVER 8601113-299 $ $ $ $
CONTROLLER MODULE 8601113-290 $ $ $ $
POWER SUPPLY, SAN 8601113-291 $ $ $ $
2.5" SAS DISK, SAN 8601113-292 $ $ $ $
PANEL, TOUCH 8601113-811 $ $ $ $
BATTERY TEL-30 $ $ $ $
DC CONTACTOR GX12-CCB $ $ $ $
ASSEMBLY, FAN, 48V 8601113-807 $ $ $ $
ETHERNET SWITCH, 5-PORT
NOTE D – The table below establishes stepladder pricing for CLINs 0001 through 0008, 1001 through 1008, 2001 through 2008, 3001 through 3008, 4001 through 4008. The Section B Firm Fixed Price (FFP) amount and the funding provided in each delivery order shall be unilaterally established based on the stepladder pricing in the table below. Every thirty (30) days beginning upon contract award, the Government shall review all orders placed within that timeframe to determine the final unit price. The final unit price will be based on the total number of CPS units, regardless of configuration, ordered within that 30 day timeframe. The Government will retain the unilateral right to amend issued delivery orders at the final unit price.
Note D - Table 1 (BASE YEAR) CPS TI 16 Step-Ladder Line Items
Unit Price CLIN Qty 1 Qty 2 Qty 3 Qty 4-6 Qty 7-9 Qty 10-12 Qty 13-15 Qty 16+ 0001 $ $ $ $ $ $ $ $ 0002 $ $ $ $ $ $ $ $ 0003 $ $ $ $ $ $ $ $ 0004 $ $ $ $ $ $ $ $ 0005 $ $ $ $ $ $ $ $ 0006 $ $ $ $ $ $ $ $ 0007 $ $ $ $ $ $ $ $ 0008 $ $ $ $ $ $ $ $
Note D - Table 2 (OPTION YEAR 1)
Unit Price
CLIN Qty 1 Qty 2 Qty 3 Qty 4-6 Qty 7-9 Qty 10-12 Qty 13-15 Qty 16+ 1001 $ $ $ $ $ $ $ $ 1002 $ $ $ $ $ $ $ $ 1003 $ $ $ $ $ $ $ $ 1004 $ $ $ $ $ $ $ $ 1005 $ $ $ $ $ $ $ $ 1006 $ $ $ $ $ $ $ $ 1007 $ $ $ $ $ $ $ $ 1008 $ $ $ $ $ $ $ $
Note D - Table 3 (OPTION YEAR 2)
Unit Price
CLIN Qty 1 Qty 2 Qty 3 Qty 4-6 Qty 7-9 Qty 10-12 Qty 13-15 Qty 16+ 2001 $ $ $ $ $ $ $ $ 2002 $ $ $ $ $ $ $ $ 2003 $ $ $ $ $ $ $ $ 2004 $ $ $ $ $ $ $ $
2005 $ $ $ $ $ $ $ $ 2006 $ $ $ $ $ $ $ $ 2007 $ $ $ $ $ $ $ $ 2008 $ $ $ $ $ $ $ $
Note D - Table 4 (OPTION YEAR 3)
Unit Price
CLIN Qty 1 Qty 2 Qty 3 Qty 4-6 Qty 7-9 Qty 10-12 Qty 13-15 Qty 16+ 3001 $ $ $ $ $ $ $ $ 3002 $ $ $ $ $ $ $ $ 3003 $ $ $ $ $ $ $ $ 3004 $ $ $ $ $ $ $ $ 3005 $ $ $ $ $ $ $ $ 3006 $ $ $ $ $ $ $ $ 3007 $ $ $ $ $ $ $ $ 3008 $ $ $ $ $ $ $ $
Note D - Table 5 (OPTION YEAR 4)
Unit Price
CLIN Qty 1 Qty 2 Qty 3 Qty 4-6 Qty 7-9 Qty 10-12 Qty 13-15 Qty 16+ 4001 $ $ $ $ $ $ $ $ 4002 $ $ $ $ $ $ $ $ 4003 $ $ $ $ $ $ $ $ 4004 $ $ $ $ $ $ $ $ 4005 $ $ $ $ $ $ $ $ 4006 $ $ $ $ $ $ $ $ 4007 $ $ $ $ $ $ $ $ 4008 $ $ $ $ $ $ $ $
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
THE FOLLOWING STATEMENT OF WORK (SOW) IS APPLICABLE TO ALL LINE ITEMS UNLESS
OTHERWISE SPECIFIED
1.0 SCOPE
This Statement of Work (SOW) defines the efforts required for the manufacture, assembly, and test of the Common Processing System (CPS) equipment, spares, and associated technical services. The CPS is designed to support the Program Executive Office for Integrated Warfare Systems’ (PEO IWS) implementation of an Open Architecture (OA) for Navy combat systems. The CPS maximizes flexibility and modularity by incorporating commercial hardware and software compliant with Open Architecture Computing Environment (OACE) technologies and standards, when available. The CPS provides the computer processing and memory, data storage and extraction, and Input/Output (I/O) interfaces to support host software applications of Navy combat systems.
The CPS contract will produce three variants of populated cabinets – a Core Computing System (CCS) Cabinet, an Advanced Storage Area Network (ASAN) Cabinet, and a Processing and Storage Subsystem (PS2) Cabinet. The CCS provides core computing resources for Navy Combat System application programs. The ASAN Cabinet provides storage for load files, program data storage, video files, data extraction files, database management, and other mass storage and archive requirements for the Combat System. The PS2 cabinet combines processing and storage into a single cabinet with reduced processing and storage capacities.
1.1 BACKGROUND
The Common Processing System (CPS) equipment procurement provides a processing and storage system that supports the Navy’s planned implementation of Open Architecture (OA) for Navy combat systems. Technical requirements were originally driven by the AEGIS Modernization (AMOD) program of record but have been expanded to include the requirements of AEGIS new ship construction, Ship Self Defense System (SSDS), Aircraft Carrier – Tactical Support Center (CV-TSC), and the Surface Electronic Warfare Improvement Program (SEWIP).
CPS provides computer processing and memory, data storage and extraction, and I/O interfaces to support host software applications of Navy combat systems.
CPS consists of the CPS Enclosure Assembly and three variants: CCS, a processing and I/O subsystem; ASAN, a storage/extraction Subsystem; and PS2, consisting of Processing, I/O, and Storage subsystems. The Processing Subsystem provides the computing resources to execute Navy combat system application programs on Navy platforms. The I/O Subsystem provides the resources required to interface the processing and storage hardware to various external elements. The Storage/Extraction Subsystem provides the mass storage resources required for Operating System (OS) image storage, program storage, data extraction, and database management. Through its ability to host multiple types of software applications, CPS supports the processing resource requirements for multiple Combat and Weapon systems.
2.0 APPLICABLE DOCUMENTS.
The following documents form part of the SOW to the extent specified herein. In the event of a conflict between the documents referenced herein and the contents of this SOW, the SOW shall be considered the superseding requirement.
2.1 Government Documents
Title Date Program Executive Office, Integrated Warfare Systems (PEO IWS) – Deputy Commander, Naval Sea Systems Command Warfare Systems Engineering Directorate (NAVSEA 06) Technical Review Manual (TRM)
18 Dec 2009
PEO IWS AEGIS Weapon System Diminishing Manufacturing Sources and Material Shortages (DMSMS) Plan
June 2005
PEO IWS Program Plan PEO IWS Instruction 4130.1B PEO IWS Enterprise Configuration Control Process, 14 September2011
PEOIWSINST 3058.1 Risk Management 01 August 2004 Program Executive Office, Integrated Warfare Systems 28 January 2012
(PEO IWS) Instruction (INST) 5450.1 Naval Sea Systems Command Warfare Systems Engineering Directorate (NAVSEA) Contracts Handbook
09 December 2009
Public Law (P.L.) 102 – 484, Section 4219 (h) 23 September 1996 Federal Acquisition Regulation (FAR) 25 July 2014 Naval Operations Instruction 2450.2 Electromagnetic Compatibility Program Within the Department of the Navy
08 January 1990
Configuration Management Plan (CMP) for Program Executive Office, Integrated Warfare Systems
(PEO IWS) 1.0
17 January 2014
Naval Sea Systems Command Warfare Systems Engineering Directorate (NAVSEA) Instruction 9078.22, Naval Ships Critical Safety Items (CSI) Program Technical Requirements
15 May 2008
Program Executive Office, Integrated Warfare Systems (PEO IWS) Instruction (INST) 5450.1
01 July 2012
Naval Operations Instruction 3432.1 , Operations Security
04 August 2011
Naval Sea Systems Command Warfare Systems Engineering Directorate (NAVSEA) Clinger-Cohen Act (CCA) Compliance Guide
April 2008
Department of the Navy DON Policy on Digital Product/Technical Data Memorandum
23 October 2004
SECNAV Instruction 5000.2E Department of the Navy Implementation and Operation of the Defense Acquisition System and Joint Capabilities Integration and Development System
01 September 2011
2.2 Joint Chiefs of Staff, Department of Defense, and DoD Services Documents Title Date Defense Acquisition Guidebook 4.3.3.4.7, Production Readiness Review (PRR) https://dag.dau.mil
06 August 2013
DoD 5220.22M Defense Security Service (DSS) National Industrial Security Program Operating manual
(NISPOM)
28 February 2006
Department of Defense Instruction (DoDI) 5000.1 The Defense Acquisition System
12 May 2003
Department of Defense Instruction (DoDI) 5000.2 Operation of the Defense Acquisition System
25 November 2013
Department of Defense Instruction (DoDI) 5000.4-M-1 Cost and Software Data Reporting (CSDR) Manual
04 November 2011
Defense Federal Acquisition Regulations (DFARS) 252.211-7000
October 2010
Department of Defense Standard DoD-STD-1679A 22 October 1983 DCPR-1 Configuration Management Process 06 February 2003 Department of Defense Instruction (DoDI) 8500.1 14 March 2014 Department of Defense Instruction (DoDI) 5200.39 Critical Program Information (CPI) Protection within the Department of Defense
16 July 2008
Department of Defense Instruction (DoDI) 4140.67 26 April 2013
Department of Defense Counterfeit Prevention Policy Department of Defense Instruction (DoDI) 4160.21-M Defense Materiel Disposition Manual
August 1997
Department of Defense Instruction (DoDI) 4160.28 Department of Defense Demilitarization (DEMIL) Program
07 April 2011
Defense Federal Acquisition Regulations (DFARS) 252.245-7003 Contractor Property Management System Administration
April 2012
2.3 Military Standards (MIL-STD)
MIL-STD-129P DoD Standard Practice, Military marking for Shipment and Storage, 19 September 2007
MIL-STD 130N Department of Defense Standard Practice Identification Marking of U.S. Military Property
15 June 2007
MIL-STD-882E System Safety 11 May 2012 MIL-STD-1378E Requirements for Employing Standard Electronic Modules
21 April 1989
MIL-STD-461F Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment
10 December 2007
MIL-STD 973 Configuration Management 17 April 1992
2.4 Other Military Documents
MIL-D-23140D Drawings, Installation Control, for Shipboard Electronic Equipment
30 April 1992
MIL-DTL-31000C Technical Data Packages, Detail Specification
09 July 2004
MIL-P-24534A Planned Maintenance System:
Development Of Maintenance Requirement Cards, Maintenance Index Pages, and Associated Documentation
16 September 2009
MIL-PRF-29612B Training Data Products 31 August 2001 ASTM F 1166 Standard Practice for Human Engineering Design for Marine Systems, Equipment, and Facilities
01 October 2013
2.5 Handbooks
MIL-HDBK-881A Work Breakdown Structures For Defense Materiel Items
02 January 1998
MIL-HDBK-237D Electromagnetic Environmental Effects and Spectrum Supportability Guidance for the Acquisition Process
20 May 2005
MIL-HDBK-61B Configuration Management Guidance
10 September 2002
2.6 Non-Government Documents/ Commercial Standards
ANSI/ASQC Q9001-2008 Quality Systems - Model for Quality Assurance in Design, Development, Production, Installation and Servicing
15 November 2008
ANSI/EIA-649B, “Configuration Management Standard”
01 April 2011
2.7 Non-Government Documents
ASME Y14.24-2012, Types and Applications of Engineering Drawings
American Society for Testing of Materials
(ASTM)
ASTM F1337-10
Standard Practice For Human Engineering Program Requirements For Ships And Marine Systems, Equipment, And Facilities
IEEE/EIA 12207.0-2008 Software Life Cycle Processes
31 January 2008
IEEE/EIA 12207.1-1997 Software Life Cycle Processes – Life Cycle Data
21 December 1998
IEEE/EIA 12207.2-1997 Software Life Cycle Processes – Implementation Considerations
International Organization for Standards (ISO) ISO 9001:2008, Quality Management Systems – Requirements
30 November 2008
International Organization for Standards (ISO) ISO 10007:2003 Quality Management Guidelines for Configuration Management
01 June 2003
Institute of Electrical and Electronics Engineers (IEEE)/EIA-649-1998 National Consensus Standard for Configuration Management
10 July 1998
3.0 REQUIREMENTS.
3.1 GENERAL The Contractor shall furnish all labor and materials, other than the items provided by the Government as GFE/GFI/GFP as identified in Attachment J-3, necessary for the manufacture, assembly, and test of CPS equipment, spares, and associated technical services. Program information, deliveries, and data shall be handled in accordance with the Contract Security Specification, (DD Form 254, Attachment J-1).
3.2 Program Management and Control (Applicable to All CLINs). The Contractor shall provide program management oversight to ensure all work conducted within this contract is planned and executed in a manner that will achieve all quality, schedule, and cost objectives.
3.2.1 Program Management Office. The Contractor shall establish a Program Management Office that is responsible for the management and control of Program Management Plan (CDRL A001) elements in order to support the successful on-time delivery of the contract requirements. The Program Management Plan shall incorporate detailed production planning, milestones, and metrics capable of supporting the execution of all tasks required by the Contract and this SOW.
Deliverable Data Item (See DD-1423):
CDRL A001: “Program Management Plan”
3.2.2 Program Manager. The Contractor shall designate a Program Manager who will ensure all work conducted within this contract is planned and executed in a manner that will achieve all management, technical, logistics, budget, and schedule objectives.
3.2.3 Subcontractor Management. The Contractor is responsible for executing the requirements of this contract and shall institute appropriate management actions relative to subcontractor performance. The Contractor shall flow down the requirements of this entire SOW to all Subcontractors, regardless of contract value. Requirements that are contractually specified shall apply to Subcontractor performance; however, the Contractor shall be accountable for the subcontractor’s compliance and is responsible for ensuring all deliverables comply with the contract requirements.
3.2.4 Monthly Progress, Status and Management Reports. The Contractor shall deliver a Contractor’s Progress, Status and Management Report (CDRL A002). Data item requirements shall include:
• Status of significant program events (e.g. Post Award Conference, Interchange Meetings, Program Reviews);
• Status of significant/major production and/or issue resolution;
• Cost reporting (funded, expended, monthly burn rates, and remaining) for all non-FFP CLINs by Delivery
Order;
• Risk assessment;
• Environmental Safety and Occupational Health (ESOH) hazard status;
• Schedules for delivery orders and equipment production/deliveries;
• Action item status;
• Invoices submitted to Wide Area Work Flow (WAWF).
CDRL A002: “Contractor’s Progress, Status and Management Report”
3.2.5 Meetings. The Contractor shall coordinate, prepare for, conduct, facilitate, and participate in reviews, meetings, and conferences as specified herein. The Government reserves the right to attend meetings between the prime and its subcontractors. The Contractor shall provide the Government notice of any such meeting in writing at least fourteen (14) days in advance. The Contractor shall provide a Conference Agenda (CDRL A003), Presentation Material (CDRL A004), and Conference Minutes (CDRL A005) for each meeting. At a minimum, the Contractor shall support meetings identified within the following paragraphs. Teleconferencing shall be used whenever possible; otherwise, meetings shall be held at the Contractor’s facility. When teleconferencing is required, the Contractor shall provide teleconferencing services, including web conferencing and telephone dial-in numbers, at the request of the Contracting Officer’s Representative (COR). These services shall be able to accommodate up to forty (40) attendees. Reference the table below for an overview of the meetings that will be required by this Contract.
Meeting SOW Paragraph Reference Frequency Bi-Weekly Program Management Reviews 3.2.5.1 Every two weeks Program Assessment Reviews (PARs) 3.2.5.2 Quarterly Integrated Product Team (IPT) Meetings 3.2.5.3, 3.3.3 Monthly Post Award Kickoff Meeting 3.2.5.4 Once (Award + 45 calendar days) Local Configuration Control Board (LCCB) 3.2.5.5, 3.6.1, 3.6.3 Monthly Diminishing Manufacturing Sources and Material Shortages (DMSMS) Meeting 3.2.5.6, 3.8 Quarterly
Reliability/Maintainability (R&M) Program Review 3.2.5.7, 3.9.2 Quarterly
Problem Review Board (PRB) 3.2.5.8, 3.9.4 Monthly Interchange Meeting 3.2.5.9, 3.4.2.1 Four per exercised FAU
Production Readiness Review (PRR) 3.2.5.10, 3.4.1 NLT 4 months after Contract Award
CDRL A003: “Conference Agenda”
CDRL A004: “Presentation Material”
CDRL A005: “Conference Minutes”
3.2.5.1 Bi-Weekly Program Management Reviews (PMRs). The Contractor shall coordinate, participate in, and facilitate Bi-Weekly PMRs. Bi-Weekly PMRs shall be conducted in person at the Contractor’s plant or via teleconferencing with the Contractor providing a summary of its current program status to include Contractor’s Progress, Status and Management Reports (CDRL A002). The current program status report shall contain the following main sections: Summary, Accomplishments, Current Status, Problem Areas, Risks and Mitigations, Cost and Schedule Data, and Future Plans.