Appendix J - FCP 25 October 2009.xls
XLS spreadsheet 27 KB Posted
- Attached to
- Sustainment, Modification, and Installation Program in support of P-3 Aircraft (all T/M/S)
- Solicitation number
- N00019-09-R-0216
About this file
Appendix J FCP dtd 25Oct09
View the file
Other files
Show 40 more
Latest 50 of 175 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fatigue Critical Parts
| Part Number | Nomenclature | Testing Method |
| OUTER WING | ||
| 938811-*** | PANEL - OW LOWER # 1 | |
| 981811-*** | PANEL - OW LOWER # 1 | *FTT |
| 938812-*** | PANEL - OW LOWER # 2 | |
| 981812-*** | PANEL - OW LOWER # 2 | *FTT |
| 938813-*** | PANEL - OW LOWER # 3 | |
| 981813-*** | PANEL - OW LOWER # 3 | *FTT |
| 938814-*** | PANEL - OW LOWER # 4 | |
| 981814-*** | PANEL - OW LOWER # 4 | *FTT |
| 938815-*** | PANEL - OW LOWER # 5 | *FTT required for -107/-108 |
| 938816-*** | PANEL - OW LOWER # 6 | *FTT required for -107/-108 |
| 938817-*** | PANEL - OW LOWER # 7 | *FTT required for -107/-108 |
| 938818-*** | PANEL - OW LOWER # 8 | *FTT required for -107/-108 |
| 938819-*** | PANEL - OW LOWER # 9 | *FTT required for -107/-108 |
| 938801-*** | PANEL - OW UPPER # 1 | *FTT required for -201/-202 |
| 938802-*** | PANEL - OW UPPER # 2 | *FTT required for -201/-202 |
| 938803-*** | PANEL - OW UPPER # 3 | *FTT required for -201/-202 |
| 938804-*** | PANEL - OW UPPER # 4 | *FTT required for -201/-202 |
| 938805-*** | PANEL - OW UPPER # 5 | *FTT required for -201/-202 |
| 938806-*** | PANEL - OW UPPER # 6 | *FTT required for -201/-202 |
| 938807-*** | PANEL - OW UPPER # 7 | *FTT required for -201/-202 |
| 938808-*** | PANEL - OW UPPER # 8 | *FTT required for -201/-202 |
| 938809-*** | PANEL - OW UPPER # 9 | *FTT required for -201/-202 |
| 939202-*** | CAP - OW AFT UPPER | |
| 939203-*** | CAP - OW AFT LOWER | |
| 939204-*** | WEB - OW AFT | |
| 938320-*** | CAP - OW FWD UPPER | **Tensile Test |
| 938321-*** | CAP - OW FWD LOWER | |
| 981321-*** | CAP - OW FWD LOWER | **Tensile Test |
| 938322-*** | WEB - OW FWD | |
| 982195-*** | WEB - OW FWD | |
| 939192-*** | FITTING - OW FWD LWR FWD | |
| 939193-*** | FITTING - OW FWD LWR AFT | |
| 939196-*** | FITTING - OW FWD UPPER FWD | |
| 939191-*** | FITTING - OW FWD UPPER AFT | |
| 939194-*** | FITTING - OW AFT UPPER | |
| 939198-*** | FITTING - OW AFT LWR | |
| 939329-*** | #2 & 3 Nacelle Attach Plate | |
| 982121-*** | #2 & 3 Nacelle Attach Plate | |
| 810053-*** | #2 & 3 Nacelle Attach Plate | |
| 982120-*** | #2 & 3 Nacelle Attach Plate | |
| 810052-*** | #2 & 3 Nacelle Attach Plate | |
| 982123-*** | #2 & 3 Nacelle Attach Plate | |
| 810051-*** | #2 & 3 Nacelle Attach plate | |
| 982122-*** | #2 & 3 Nacelle Attach plate | |
| 810055-*** | #1 & 4 Nacelle Attach Plate | |
| 982128-*** | #1 & 4 Nacelle Attach Plate | |
| 810056-*** | #1 & 4 Nacelle Attach Plate | |
| 982129-*** | #1 & 4 Nacelle Attach Plate | |
| 919144-*** | #1 & 4 Nacelle Attach Plate | |
| 919139-*** | #1 & 4 Nacelle Attach Plate | |
| 902529-*** | RIB - MLG TRUSS, WS 167 | |
| SKT-P3-301-00* | RIB - MLG TRUSS, WS 167 | |
| 902530-*** | RIB - MLG TRUSS, WS 209 | |
| 606A0102-00* | RIB - MLG TRUSS, WS 209 | |
| 939515-*** | CAP - BL 65 WING RIB, LOWER | |
| E10-23433-* | CAP - BL 65 WING RIB, LOWER | **Tensile Test |
| 939516-*** | PLATE - WING BL65 LOWER SPLICE | |
| CENTER WING | ||
| 938831-*** | PANEL - CW UPPER # 1 | *FTT required for -105 |
| 938832-*** | PANEL - CW UPPER # 2 | *FTT required for -105 |
| 938833-*** | PANEL - CW UPPER # 3 | *FTT required for -105 |
| 938834-*** | PANEL - CW UPPER # 4 | *FTT required for -105 |
| 938835-*** | PANEL - CW UPPER # 5 | *FTT required for -105 |
| 938836-*** | PANEL - CW UPPER # 6 | *FTT required for -105 |
| 938837-*** | PANEL - CW UPPER # 7 | *FTT required for -105 |
| 938838-*** | PANEL - CW UPPER # 8 | *FTT required for -105 |
| 938839-*** | PANEL - CW UPPER # 9 | *FTT required for -105 |
| 938821-*** | PANEL - CW LOWER # 1 | *FTT required for -115 |
| 938822-*** | PANEL - CW LOWER # 2 | *FTT required for -115 |
| 938823-*** | PANEL - CW LOWER # 3 | *FTT required for -115 |
| 938824-*** | PANEL - CW LOWER # 4 | *FTT required for -117 |
| 938825-*** | PANEL - CW LOWER # 5 | *FTT required for -115 |
| 938826-*** | PANEL - CW LOWER # 6 | *FTT required for -115 |
| 938827-*** | PANEL - CW LOWER # 7 | *FTT required for -115 |
| 938828-*** | PANEL - CW LOWER # 8 | *FTT required for -115 |
| 938829-*** | PANEL - CW LOWER # 9 | *FTT required for -115 |
| 901606-*** | CAP - CW FWD UPPER | |
| 925251-*** | CAP - CW FWD LOWER | **Tensile Test |
| 925498-*** | WEB - CW FWD | |
| 900906-*** | CAP - CW AFT UPPER | |
| 900907-*** | CAP - CW AFT LOWER | |
| 900908-*** | WEB - CW AFT | |
| 939195-*** | FITTING - CW FWD LWR | |
| 939197-*** | FITTING - CW AFT LWR | |
| 901721-*** | RING FITTING - FORWARD | |
| 901722-*** | RING FITTING - AFT | |
| * The fracture toughness test specimen shall be taken from the parent extrusion and tested in the L-T direction. The L-T direction means that the specimen is loaded in the longitudinal direction and the crack orientation is the transverse direction. | ||
| Specimen thickness shall be maximized within the section. Contractor shall perform testing in accordance with the requirements of ASTM E 399. The data obtained from these tests shall be plane strain fracture toughness KIc. | ||
| Test results failing to meet the validity requirements of ASTM E 399 shall be interpreted in accordance with the requirements of ASTM B 645. Contractor shall maintain specimen identity throughout specimen fabrication and testing. | ||
| ** Tensile specimens shall be machined to ASTM E8 and ASTM B 557 from final tempered product with acceptance values per AMS 4293. The data required from these test are tensile strength (Ftu), yield strength at 0.2% offset (Fty), and percent elongation (e%). The Contractor shall maintain specimen identity throughout specimen fabrication and testing. | ||
| NOTE -- The parts with a blank under the Testing Method column are not manufactured from 7249 material and do not require any special testing to verify material properties. |
&F Page &P of &N
Sheet2
Sheet3
File details come from the government source that posted it. Updated .