MP04-M4-0.pdf
PDF 348 KB Posted
- Attached to
- GLENDALE FIRE STATION State and local contract opportunity
- Solicitation number
- ITB 24-29
- Issued by
- Walton County, Florida
About this file
This is a technical drawing specification document for the vehicle exhaust system installation at the Glendale Fire Station project, prepared by Winton Engineering for the Walton County Board of County Commissioners in Florida. The drawing details the mechanical specifications for a ceiling-mounted exhaust fan system designed to remove vehicle emissions from the fire station garage. The system includes a CF363-5 fan with 3,300 CFM airflow capacity operating at 3,450 RPM, powered by 208-230 volt, 3-phase electrical service with a 5 HP motor requiring a 30 AMP breaker and #8 THHN wire. The vehicle exhaust system consists of four hose drops at 600 CFM per drop, utilizing spiral seam galvanized steel ductwork fabricated and installed in accordance with Chapter 6 OBBC MC and SMACNA standards. The specification includes a control panel (Part # 500179-08), rain cap (Part # 500157-12), suction rails, transition elbows, high-temperature hose, nozzles, tailpipe connectors, and a fresh air intake system. The document is dated August 2023 and includes general construction notes requiring contractors to verify all dimensions through field measurement, comply with 2017 ICC Building Code standards, coordinate with manufacturers' recommendations, and obtain prior approval from the City Fire Department for any roof penetrations or cutting operations.
The drawing specifies that all materials and methods shall conform to applicable federal, state, and local codes with strict adherence to building standards and manufacturer specifications. The contractor is required to balance the exhaust system to meet specified air quantities and coordinate exact equipment locations with existing fire department infrastructure, lighting, and conditions. The specification notes that wireless control panel activation and automatic fan control components may be required for complete installation. As indicated in the remarks section, this design represents the sole property of the designer, Magnegrip, and any approved substitutions are at the risk of the owner. The document was professionally sealed by Robin Winton, a Florida-licensed Professional Engineer (License No. 56206), with an owner change dated May 14, 2024, reflecting design modifications during the project development phase.
View the file
Other files for this state and local contract opportunity
Show all 45
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CEILING
STRUCTURE
VIBRATION
ISOLATORS
FAN MOUNTING
SYSTEM
CF FAN
RAIN CAP
EXHAUST
STACK
BRACING
WALL
FAN ELEVATION
STRAIGHT SUCTION RAIL
FRONT ELEVATION
MOUNTING LEG
ASSEMBLY
RAIL
STRAIGHT SUCTION RAIL
SIDE ELEVATION
INLET PLENUMCEILING LINE
RAIL LIPS
LIFTING BALANCER
ELBOW
CRAB ASSEMBLY
SYSTEM
CONTROL
PANEL
12"Ø 10"Ø
8" Ø
8" Ø
8" Ø
8" Ø
8" Ø
8" Ø
"Ø
SS
R
M
PR
O -7
SS
R
M
PR
O -7
SS
R
M
PR
O -7
TO MAIN
SERVICE
PANEL
GENERAL CONSTRUCTION NOTES:
1. FOR THE PURPOSE OF CLEARNESS AND LEGIBILITY DRAWINGS ARE DIAGRAMMATIC AND DESIGN
INTENT ONLY.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS BY FIELD MEASUREMENT BEFORE BEGINNING ANY
FABRICATION OR CONSTRUCTION.
2. ALL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES
IN ACCORDANCE WITH 2017 ICC (IBC, IMC).
3. ALL NEW MATERIAL METHODS, AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH
THE BUILDING STANDARDS AS APPROVED.
4. CONTRACTOR SHALL INSTALL ALL EQUIPMENT N STRICT ACCORDANCE WITH MANUFACTURES'
RECOMMENDATIONS.
5. CONTRACTOR SHALL COORDINATE EXACT LOCATION OF EXHAUST FANS, DUCTWORK, AND EXHAUST DROPS WITH EXISTING IN-PLACE CITY FIRE DEPARTMENTS EQUIPMENT, LIGHTING, AND ALL EXISTING
CONDITIONS.
6. ALL EXHAUST DUCTWORK SHALL BE SPIRAL SEAM GALVANIZED STEEL FABRICATED AND INSTALLED
IN ACCORDANCE WITH CHAPTER 6 OBBC MC AND SMACNA STANDARD MANUAL.
7. SHEETMETAL DUCT DIMENSIONS SHOWN ARE AIRWAY DIMENSIONS.
8. BALANCE EXHAUST SYSTEM AND EACH EXHAUST DROP MEET AIR QUANTITIES AS REQUIRED.
9. CONTRACTOR SHALL COORDINATE WITH CITY FIRE DEPARTMENT PRIOR TO ANY PENETRATION OR
ROOF CUTTING.
FAN SCHEDULE
FAN TYPE ID#
AIRFLOW
(CFM) RPM
STATIC
PRESSURE
(IN - WC)
VOLTS /
PHASE HP BREAKER WIRE
MAGNEGRIP CF363-5 3300 3450 6 SP
208-230v 3ph 4w 5 30 AMP #8THHN
VEHICLE EXHAUST SYSTEM
DESCRIPTION PART # QTY REMARKS
CONTROL PANEL 500179-08 1
RAIN CAP 500157-12 1
SUCTION RAIL SSRMPRO-721 2 1 HOSE DROP EACH
SUCTION RAIL SSRMPRO-722 1 2 HOSE DROPS EACH
TOTAL # OF HOSE DROPS: 4 CFM PER HOSE DROP: 600 CFM
REMARKS:
A. ITEM HAS BEEN SPECIFIED FOR QUALITY AND PERFORMANCE ANY APPROVED SUBSTITUTION
IS AT THE RISK OF THE OWNER.
B. PROVIDE TRACK OR RAIL SYSTEM, TRANSITION ELBOW, HIGH TEMPERATURE HOSE, HOSE
CLAMPS, NOZZLES, TAILPIPE CONNECTORS, FRESH AIR INTAKE, AND OTHER ITEMS REQUIRED
FOR A COMPLETE INSTALLATION.
C. PROVIDE WIRELESS CONTROL PANEL ACTIVATION, PRESSURE SENSORS,WIRELESS
TRANSMITTERS, AND ADDITIONAL COMPONENTS IF REQUIRED FOR AUTOMATIC FAN CONTROL.
D. VEHICLE EXHAUST SYSTEM DESIGN AND DRAWING IS THE SOLE PROPERTY OF THE
DESIGNERS, MAGNEGRIP.
E. DETAILS MAY NOT REPRESENT THE SAME KIND OF VEHICLE IN PLAN VIEW.
F. DETAILS ARE MEANT TO ILLUSTRATE “TYPICAL” ELEVATION VIEWS.
5/
/2
8:
:2
AM
D:
\W
IN
TO
N
EN
GI
NE
ER
IN
G\
JO
BS
\2
3\
-5
GL
EN
DA
LE
F
IR
ST
S
TA
TI
ON
DE
W
BE
RR
Y\ M
PS
HE
ET
S.
DW
G
A
54321
B
C
D
E
APPROVED BY
CHECKED BY
SHEET NO.
TITLE
DRAWN BY
DATE
PROJECT NO.
SCALE
SEAL
REVISIONS
NO. DESCRIPTION DATE
PRELIMINARY
877 CR 393 North Santa Rosa Beach, FL 32459 850.267.0759
ROBIN WINTON, P.E. 56206
8'0' 16'
SCALE: 1/8" = 1' - 0"
4'
M4.0
VEHICLE EXHAUST
PLAN
RPW
RPW
AUGUST 2023
50150622
GL
EN
DA
LE
F
IR
E
ST
AT
IO
N
BO
AR
D
OF
C
OU
NT
Y
CO
M M
IS
SI
ON
ER
S W
AL
TO
N
CO
UN
TY
FL
OR
ID
A
RPW
ROBIN WINTON, STATE OF FLORIDA, PROFESSIONAL ENGINEER. LICENSE NO. 56206. THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY ROBIN WINTON ON THE DATE INDICATED HERE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
1 OWNER CHANGES 5/14/24
AutoCAD SHX Text
VEHICLE EXHAUST PLAN
AutoCAD SHX Text
SCALE: 3/16" = 1'0"
| Sheets and Views |
| MP04-M4-0 |
File details come from the government source that posted it. Updated .