This document is a Lead and Asbestos Report for a federal contract opportunity related to landslide repairs on several highway segments in Lares, Puerto Rico.
The report summarizes the findings from an environmental assessment conducted to determine the presence of asbestos-containing materials (ACM) and lead-based paint (LBP) on PR-128, PR-124, and related highway segments. The assessment found no ACM or LBP in the evaluated areas, with the exception of a concrete structure along PR-124 Km 16.0 that could not be accessed due to safety concerns. The report includes detailed inspection data, test results, and certifications of the negative findings for ACM and LBP.
The related federal contract opportunity is for the Landslide Repairs in Lares, Puerto Rico project under Solicitation Number 693C73-24-B-000011. The overall project is expected to cost between $5,000,000 to $10,000,000 and will be split into multiple work schedules/contract options. The work includes embankment reconstruction, slope systems, walls, drainage, paving, and other repairs on the affected highway segments. Bid documents are expected to be issued on or about May 9, 2024.
View the file
Other files
Show 40 more
Latest 50 of 52 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THE ATMOSPHERIC ASSESSMENT GROUP
Adolfo Valdés-Agrait; M. Sc. Environmental, Health and Safety Senior Partner Consultant and Training Facility P. O. Box 219 e-mail: taagroup2@gmail.com Mercedita, Puerto Rico 00715 (787) 504-0279
PROYECTO DE EVALUACIÓN Y REPARACIÓN DE
DAÑOS Y DESLIZAMIENTOS EN CARRETERA
PR 124 EN LAS MARÍAS, PUERTO RICO
PROYECTO NÚM. AC-809544
REPORTE DE HALLAZGOS PARA LA PRESENCIA DE
MATERIALES DE CONSTRUCCIÓN CON CONTENIDO DE
ASBESTO Y DE PINTURA CON BASE DE PLOMO
Preparado por: The Atmospheric Assessment Group
Preparado para: Autoridad de Carreteras y Transportación (ACT)
DICIEMBRE 2019
mailto:taagroup2@gmail.com
Jose A. Batlle & Asociados Page 2 Grupo B-Reporte de Hallazgos MCA & PBP Diciembre 2019
TABLA DE CONTENIDO
Página de Presentación 1
Tabla de Contenido 2
Certificación Profesional 3
1.0 Introducción 4
2.0 Protocolo de Evaluación 5
3.0 Resumen de Hallazgos 6
3.1 Hallazgos para Materiales con Asbesto 6
3.2 Hallazgos para Pintura con Base de Plomo 6
4.0 Conclusión del Estudio 8
5.0 Acuerdo de Confidencialidad 8
6.0 Delimitación del Estudio 8
LISTA DE TABLAS
Tabla Núm. 1- Grupo “B’; Las Marías, Puerto Rico 4
Tabla Núm. 2- Hallazgos para Material con Asbesto 7
Tabla Núm. 3- Hallazgos para Pintura con Base de Plomo 7
APÉNDICES
A Localización del Proyecto; PR-124
B Certificación de Inspectores de Asbesto y de Plomo
C-1 Resultados de la Evaluación para la Presencia de Asbesto (MCA)
C-2 Evidencia Pictórica de la Evaluación para Asbesto (MCA)
D-1 Resultados de la Evaluación para la Presencia de Plomo (PBP)
D-2 Evidencia Pictórica de la Evaluación para Plomo (PBP)
D-3 XRF Performance Characteristic Sheet
E-1 Certificación Negativa de Presencia de Asbesto (MCA)
E-2 Certificación Negativa de Presencia de Plomo (PBP)
Jose A. Batlle & Asociados Page 3
PROYECTO DE EVALUACIÓN Y REPARACIÓN DE
DAÑOS Y DESLIZAMIENTOS EN CARRETERAS
PR 124 EN LAS MARÍAS, PUERTO RICO
PROYECTO NÚM. AC-809544
REPORTE DE EVALUACIÓN AMBIENTAL PARA LA
DETERMINACIÓN DE LA PRESENCIA DE MATERIALES DE
CONSTRUCCIÓN CON CONTENIDO DE ASBESTO (MCA) Y
DE PINTURA CON BASE DE PLOMO (PBP)
CERTIFICACIÓN PROFESIONAL
Certificamos que el informe aquí presentado, para las estructuras de referencia, fue escrito de acuerdo con las guías publicadas por la Junta de Calidad
Ambiental (JCA) y las Guías publicadas por la Agencia de Protección Ambiental
Federal (APA).
Las muestras se tomaron por Inspectores certificados por ambas agencias, y siguiendo el Protocolo de Muestreo recomendado en las publicaciones descritas.
Las muestras para la determinación de Pintura con Base de Plomo fueron obtenidas mediante el uso de un Instrumento de Fluorescencia de Rayos “X”
(XRF, por sus siglas en ingles), y por inspectores certificados por la Junta de
Calidad Ambiental.
Certificamos que la descripción y localización de nuestros hallazgos, son correctos a la fecha de este informe.
Adolfo Valdés Agrait, M. Sc.
The Atmospheric Assessment Group Asbestos Inspector & Project Designer
Jose A. Batlle & Asociados Page 4
1.0 INTRODUCCIÓN
Nuestra compañía fue contratada por el Ingeniero Edwin Ortiz, en representación de la firma Jose A. Batlle & Asociados, para desarrollar una inspección a las estructuras de referencia, y determinar la presencia y la concentración de materiales de construcción con contenido de Asbesto (MCA), y de Pintura con Base de Plomo (PBP). El producto de la inspección realizada en el lugar de referencia se presenta en este Informe con nuestros hallazgos y los resultados de las muestras tomadas.
El día 26 de Noviembre de 2019 visitamos las carreteras descritas en la Orden de
Proceder-Grupo “B”; y se levantaron los datos que aquí se describen. Las muestras se tomaron por inspectores de Asbesto y de Plomo, certificados por la Junta de Calidad
Ambiental, JCA (Apéndice A). Las muestras para la determinación de la presencia de plomo en pintura se tomaron mediante el uso de un instrumento conocido como “XRF”, (X-Ray Fluorescence, por sus siglas en ingles), y por un Inspector certificado por la
JCA. Los datos analíticos presentados cumplieron con los requisitos del Programa de
Control de Calidad del laboratorio de referencia.
Tabla Núm. 1 Grupo B; Las Marías, Puerto Rico
Proyecto Municipio Carretera y Km Extensión del Estudio Área de Estudio
ER-HWY-104 Las Marías PR 124-Km 16.0 Desde: Km 15.85 Hasta: 16.20 Aprox. 9,400 M2
ER-HWY-105 Las Marías PR 124-Km 2.4 Desde: Km 2.3 Hasta: 2.5 Aprox. 2,700 M2
ER-HWY-106 Las Marías PR 124-Km 21.9 Desde: Km 21.72 Hasta: 22.02 Aprox. 4,500 M2
ER-HWY-108 Las Marías PR 124-Km 23.4 Desde: Km 23.33 Hasta: 23.53 Aprox. 2,200 M2
Los hallazgos del estudio se presentan a continuación.
Jose A. Batlle & Asociados Page 5
2.0 PROTOCOLO DE EVALUACIÓN
La evaluación se desarrolló con el propósito de identificar las necesidades de la
Autoridad de Carreteras en el proceso de reparación de los segmentos de las carreteras que sufrieron daños y deslizamientos causados por los Huracanes Irma y
María.
Nuestra contribución al proyecto consistió en las visitas a los segmentos de carreteras descritos, el reconocimiento, investigación, y evaluación de componentes potenciales a contener Materiales de Construcción con Contenido de Asbesto, y de Pintura con Base de Plomo, análisis de las muestras obtenidas por métodos aceptados y en cumplimiento con las agencias reguladoras estatales y federales, y la preparación de
Reporte de Hallazgos del Estudio.
La cantidad de muestras obtenidas, la selección de la localización de los puntos de muestreo, y la frecuencia de las muestras, se basó en el objetivo del estudio. Se preservaron las guías de muestreo publicadas por las agencias reguladoras, y la presunción de que materiales similares en la misma área, son considerados como homogéneos. Durante la evaluación, inspeccionamos todos los materiales identificados en los segmentos de carreteras, que pudieran contener mineral de asbesto y pintura con base de plomo.
Jose A. Batlle & Asociados Page 6
3.0 RESUMEN DE HALLAZGOS
Nuestro reporte ha sido organizado de forma consistente con las guías publicadas por las agencias reguladoras. La inspección y evaluación se desarrolló siguiendo las guías actualizadas para la determinación de la presencia y la concentración de materiales sospechosos de contener Material con Contenido de Asbesto (MCA) y de Pintura con
Base de Plomo (PBP), según las definiciones publicadas por la Agencia de Protección
Ambiental Federal (EPA, por sus siglas en ingles), y por la Junta de Calidad Ambiental
(JCA).
Se tomaron muestras representativas de todos los componentes y sustratos de los segmentos de carretera con potencial de contener los materiales regulados.
3.1 Hallazgos para los Materiales con Contenido de Asbesto (MCA)
Durante nuestra investigación de campo, y visitas a los diferentes segmentos de carreteras, no se identificó ningún material con potencial de contener minerales de asbesto. No se identificó Material de Aislación Termal, ni Material de Superficie, ni
Material Misceláneo en las areas evaluadas. Por lo tanto, se emite un Certificación de
No Presencia de Asbesto en los segmentos de carreteras identificados bajo el Grupo
“B”. Se excluye de la certificación le estructura de hormigón ubicada en el segmento
PR-124 Km 16.0, de la cual no tuvimos acceso por considerarse en riesgo de deslizamiento. El Apéndice C contiene la Evaluación de Campo para MCA.
3.2 Hallazgos para la Pintura con Base de Plomo (PBP)
La pintura con base de plomo se define como aquella pintura, capa o barniz que contiene más de 1.0 mg/cm2 de plomo, medido con un XRF. Las lecturas obtenidas demuestran que no existe PBP en los segmentos de carreteras evaluadas. Por lo tanto, se emite una Certificación de NO Presencia de Pintura con Base de Plomo en los segmentos de carreteras evaluados.
Jose A. Batlle & Asociados Page 7
Los hallazgos se presentan en la Tabla Núm. 3. El Apéndice D-1 contiene la Evaluación de Campo para las áreas evaluadas para PBP. Se excluye de la certificación le estructura de hormigón ubicada en el segmento PR-124 Km 16.0, de la cual no tuvimos acceso por considerarse en riesgo de deslizamiento.
Tabla Núm. 2 Hallazgos de la Presencia de Material con Contenido de Asbesto (MCA).
Proyecto Carretera y Km Extensión del Estudio Área de Estudio Contenido de
Asbesto
ER-HWY-104 PR 124-Km 16.0 Desde: Km 15.85 Hasta: 16.20 Aprox. 9,400 M2 No se determinó presencia de materiales con potencial de contener Minerales de
Asbesto
ER-HWY-105 PR 124-Km 2.4 Desde: Km 2.3 Hasta: 2.5 Aprox. 2,700 M2
ER-HWY-106 PR 124-Km 21.9 Desde: Km 21.72 Hasta: 22.02 Aprox. 4,500 M2
ER-HWY-108 PR 124-Km 23.4 Desde: Km 23.33 Hasta: 23.53 Aprox. 2,200 M2
Se emite una Certificación de No Presencia de Material con Contenido de
Asbesto (MCA) para los segmentos de las Carreteras en el Grupo “B”, en Las
Marías, Puerto Rico. Se excluye estructure de hormigón en el tramo de carretera.
Tabla Núm. 3 Hallazgos de la Presencia de Pintura con Base de
Plomo (PBP).
Proyecto Carretera y Km Extensión del Estudio Área de Estudio Contenido de
Plomo
ER-HWY-104 PR 124-Km 16.0 Desde: Km 15.85 Hasta: 16.20 Aprox. 9,400 M2 No se determinó presencia de PBP en las muestras obtenidas.
ER-HWY-105 PR 124-Km 2.4 Desde: Km 2.3 Hasta: 2.5 Aprox. 2,700 M2
ER-HWY-106 PR 124-Km 21.9 Desde: Km 21.72 Hasta: 22.02 Aprox. 4,500 M2
ER-HWY-108 PR 124-Km 23.4 Desde: Km 23.33 Hasta: 23.53 Aprox. 2,200 M2
Se emite una Certificación de No Presencia de Pintura en Base de Plomo (PBP) para los segmentos de las Carreteras en el Grupo “B”, en Las Marías, Puerto Rico.
Se excluye estructura de hormigón en el tramo de carretera.
Jose A. Batlle & Asociados Page 8
4.0 CONCLUSIÓN
Los resultados de nuestra evaluación de campo, la confirmación de la ausencia de materiales con el potencial de contener minerales de asbesto y los análisis de las muestras para la determinación de la presencia de Pintura con Plomo, demuestran que los segmentos de las carreteras, identificados como Grupo “B”, no contienen Materiales de Construcción con Contenido de Asbesto (MCA), ni Pintura en Base de Plomo (PBP).
Por lo tanto, se emite una “Certificación de Hallazgos Negativos para la presencia de MCA y una “Certificación de Hallazgos Negativos para la presencia de PBP” para todos los segmentos identificados en las carreteras PR-124, en Las Marías, Puerto Rico.
5.0 CONFIDENCIALIDAD
Los datos generados durante nuestra evaluación, los hallazgos y resultados de análisis de las muestras, se mantienen como información privilegiada y confidencial. Ninguno de estos datos será revelado, examinado o compartido con personas ajenas al proyecto.
Solamente, y mediante autorización escrita por el titular del proyecto, se entregará copia de este informe.
6.0 DELIMITACIÓN DEL ESTUDIO
Nuestro estudio se limita a los segmentos de carreteras, según descritos como Grupo
“B” en la Tabla Núm. 1, página 4, y a la fecha del informe. Nuestra empresa no garantiza que la condición del material identificado y descrito se mantendrá en la condición encontrada.
Adolfo Valdés Agrait, M. Sc.
Jose A. Batlle & Asociados Page 9
APÉNDICE A
CERTIFICACIÓN DE LOS INSPECTORES DE ASBESTO Y PLOMO
Jose A. Batlle & Asociados Page 2 Grupo B-Reporte de Hallazgos MCA & PBP Noviembre 20019
Jose A. Batlle & Asociados Page 10
APÉNDICE B
LOCALIZACIÓN DEL PROYECTO: PR-124
PROJECT GROUP B
Area 1-ER-HWY-104 Las Marias, PR- 124 Km 16.0 (15.85 to 16.20) (X= 149,460.308, Y=244,648.091); 9400 M2
Area 2-ER-HWY-105 Las Marias, PR-124 Km 2.4 (2.3-2.5) (X= 142,429.971, Y=245,618.494); 2,700 M2
Area 3-ER-HWY-106 Las Marias, PR-124 Km 21.9 (21.72-22.02) (X= 150,375.597, Y=248,156.713); 4,500 M2
Area 4- ER-HWY-108 Las Marias, PR-124 Km 23.4 (23.33-23.53) (X= 151,161.452, Y=248,772.991); 2,200 M2
ER-HWY-104 Las Marias, PR-124 Km 16.0 (15.85 to 16.20)
ER-HWY-106 Las Marias, PR-124 Km 21.9 (21.72-22.02)
ER-HWY-108 Las Marias, PR-124 Km 23.4 (23.33-23.53)
ER-HWY-105 Las Marias, PR-124 Km 2.4 (2.3-2.5)
Jose A. Batlle & Asociados Page 11
APÉNDICE C1
EVALUACION PARA LA PRESENCIA DE ASBESTO (MCA)
ASBESTOS CONTAINING MATERIAL INSPECTION SHEET
Contratista: José A. Batlle & Asociados, C. S. P.
Localización del Proyecto: Las Marías, Puerto Rico Lugar de Inspección: ER-HWY-104; PR-124; Km. 16.0
Desde Km 15.85 hasta Km 16.20; +/- 9,400 M3
ACM TYPE Present Condition
(G-F-P)
Disturbance Potential (L-M-H)
Area Covered
Notes
Thermal System Insulation
-Tank Insulation No NA NA NA No Aplica
-Pipe Insulation No NA NA NA No Aplica
-Elbow/Fitting/Valve Insulation No NA NA NA No Aplica
-Boiler Insulation No NA NA NA No Aplica
-Duct Insulation No NA NA NA No Aplica
-Cement/Patching Compound No NA NA NA No Aplica
Surfacing Material
-Stucco/Plaster No NA NA NA No Aplica
-Spray-applied Fireproofing No NA NA NA No Aplica
-Surface Coating (Popcorn Ceiling) No NA NA NA No Aplica
-Acoustical/Decorative Surface No NA NA NA No Aplica
Miscellaneous Material
-Vinyl Floor Tiles (VFT)/Linoleum Not Checked NA NA NA No Aplica
-Mastic for Flooring Not Checked NA NA NA No Aplica
-Window Caulking Not Checked NA NA NA No Aplica
-Door Frame Caulking Not Checked NA NA NA No Aplica
-Joint Compound No NA NA NA No Aplica
-Fire Doors No NA NA NA No Aplica
-Vibration Dampening Cloths No NA NA NA No Aplica
-Ceiling Tiles No NA NA NA No Aplica
-Asphalt Roofing No NA NA NA No Aplica
-Transite (Asbestos-Cement) Panels No NA NA NA No Aplica
-Shingles No NA NA NA No Aplica
Documentos del Proyecto
Adolfo Valdés-Agrait, M. Sc. 1-Foto del frente de la Estructura
2-Direccion Física de la Estructura
Fecha: 30 de Noviembre de 2019 3-Plano de la Estructura
4-Marcar Plano con Puntos de Muestreo
Nota: Por razones de seguridad no se pudo entrar a la residencia; 5-Evidencia Pictórica de Puntos de Muestreo
Se encuentra en riesgo de deslizamiento. 6-Cantidad o Volumen de MCA (estimado)
TAAG-ACBM Form 2016-01; Mod. 14 Nov 2019 7-Cadena de Custodia
Localización del Proyecto: Las Marías, Puerto Rico Lugar de Inspección: ER-HWY-105; PR-124; Km. 2.4
Desde Km 2.3 hasta Km 2.5; +/- 2,700 M3
(G-F-P)
Disturbance Potential (L-M-H)
Area
-Pipe Insulation No NA NA NA No Aplica
-Elbow/Fitting/Valve Insulation No NA NA NA No Aplica
-Boiler Insulation No NA NA NA No Aplica
-Duct Insulation No NA NA NA No Aplica
-Cement/Patching Compound No NA NA NA No Aplica
Surfacing Material
-Stucco/Plaster No NA NA NA No Aplica
-Spray-applied Fireproofing No NA NA NA No Aplica
-Surface Coating (Popcorn Ceiling) No NA NA NA No Aplica
-Acoustical/Decorative Surface No NA NA NA No Aplica
Miscellaneous Material
-Vinyl Floor Tiles (VFT)/Linoleum No NA NA NA No Aplica
-Mastic for Flooring No NA NA NA No Aplica
-Window Caulking No NA NA NA No Aplica
-Door Frame Caulking No NA NA NA No Aplica
-Joint Compound No NA NA NA No Aplica
-Fire Doors No NA NA NA No Aplica
-Vibration Dampening Cloths No NA NA NA No Aplica
-Ceiling Tiles No NA NA NA No Aplica
-Asphalt Roofing No NA NA NA No Aplica
-Transite (Asbestos-Cement) Panels No NA NA NA No Aplica
-Shingles No NA NA NA No Aplica
Documentos del Proyecto
Adolfo Valdés-Agrait, M. Sc. 1-Foto del frente de la Estructura
2-Direccion Física de la Estructura
Fecha: 30 de Noviembre de 2019 3-Plano de la Estructura
4-Marcar Plano con Puntos de Muestreo 5-Evidencia Pictórica de Puntos de Muestreo
6-Cantidad o Volumen de MCA (estimado)
Localización del Proyecto: Las Marías, Puerto Rico Lugar de Inspección: ER-HWY-106; PR-124; Km. 21.9
Desde Km 21.72 hasta Km 22.02; +/- 4,500 M3
(G-F-P)
Disturbance Potential (L-M-H)
Area
-Pipe Insulation No NA NA NA No Aplica
-Elbow/Fitting/Valve Insulation No NA NA NA No Aplica
-Boiler Insulation No NA NA NA No Aplica
-Duct Insulation No NA NA NA No Aplica
-Cement/Patching Compound No NA NA NA No Aplica
Surfacing Material
-Stucco/Plaster No NA NA NA No Aplica
-Spray-applied Fireproofing No NA NA NA No Aplica
-Surface Coating (Popcorn Ceiling) No NA NA NA No Aplica
-Acoustical/Decorative Surface No NA NA NA No Aplica
Miscellaneous Material
-Vinyl Floor Tiles (VFT)/Linoleum No NA NA NA No Aplica
-Mastic for Flooring No NA NA NA No Aplica
-Window Caulking No NA NA NA No Aplica
-Door Frame Caulking No NA NA NA No Aplica
-Joint Compound No NA NA NA No Aplica
-Fire Doors No NA NA NA No Aplica
-Vibration Dampening Cloths No NA NA NA No Aplica
-Ceiling Tiles No NA NA NA No Aplica
-Asphalt Roofing No NA NA NA No Aplica
-Transite (Asbestos-Cement) Panels No NA NA NA No Aplica
-Shingles No NA NA NA No Aplica
Documentos del Proyecto
Adolfo Valdés-Agrait, M. Sc. 1-Foto del frente de la Estructura
2-Direccion Física de la Estructura
Fecha: 30 de Noviembre de 2019 3-Plano de la Estructura
4-Marcar Plano con Puntos de Muestreo 5-Evidencia Pictórica de Puntos de Muestreo
Localización del Proyecto: Las Marías, Puerto Rico Lugar de Inspección: ER-HWY-108; PR-124; Km. 23.4
Desde Km 23.33 hasta Km 23.53; +/- 2,200 M3
(G-F-P)
Disturbance Potential (L-M-H)
Area
-Pipe Insulation No NA NA NA No Aplica
-Elbow/Fitting/Valve Insulation No NA NA NA No Aplica
-Boiler Insulation No NA NA NA No Aplica
-Duct Insulation No NA NA NA No Aplica
-Cement/Patching Compound No NA NA NA No Aplica
Surfacing Material
-Stucco/Plaster No NA NA NA No Aplica
-Spray-applied Fireproofing No NA NA NA No Aplica
-Surface Coating (Popcorn Ceiling) No NA NA NA No Aplica
-Acoustical/Decorative Surface No NA NA NA No Aplica
Miscellaneous Material
-Vinyl Floor Tiles (VFT)/Linoleum No NA NA NA No Aplica
-Mastic for Flooring No NA NA NA No Aplica
-Window Caulking No NA NA NA No Aplica
-Door Frame Caulking No NA NA NA No Aplica
-Joint Compound No NA NA NA No Aplica
-Fire Doors No NA NA NA No Aplica
-Vibration Dampening Cloths No NA NA NA No Aplica
-Ceiling Tiles No NA NA NA No Aplica
-Asphalt Roofing No NA NA NA No Aplica
-Transite (Asbestos-Cement) Panels No NA NA NA No Aplica
-Shingles No NA NA NA No Aplica
Documentos del Proyecto
Adolfo Valdés-Agrait, M. Sc. 1-Foto del frente de la Estructura
2-Direccion Física de la Estructura
Fecha: 30 de Noviembre de 2019 3-Plano de la Estructura
4-Marcar Plano con Puntos de Muestreo 5-Evidencia Pictórica de Puntos de Muestreo
Jose A. Batlle & Asociados Page 12
APÉNDICE C2
EVIDENCIA PICTORICA DE LA EVALUACION PARA ASBESTO (MCA)
General Photos of Project Group B – Area 1 PR-124, Km 16.0
General Photos of Project Group B – Area 2 PR-124, Km 2.40
General Photos of Project Group B – Area 3 PR-124, Km 21.9
General Photos of Project Group B – Area 4 PR-124, Km 23.4
Jose A. Batlle & Asociados Page 13
APÉNDICE D1
EVALUACION PARA LA PRESENCIA DE PLOMO (PBP)
Client Name: 11/30/19
Project Name:
Address: Las Marias, Puerto Rico 2445
Reading # Room Substrate Color Component & Location
XRF
Reading
Paint
Condition Comments
1 Calibración 1.0
2 Calibración 1.1
3 Calibración 1.0
4 Km 23.4 Asphalt White Floor Line Left 0.2 Poor
5 Km 23.4 Asphalt White Floor Line Right -0.1 Poor
6 Km 23.4 Asphalt White Floor Line Left -0.2 Poor
7 Km 23.4 Asphalt White Floor Line Right 0.0 Poor
8 Km 23.4 Asphalt White Floor Line Right 0.1 Poor
9 Km 23.4 Asphalt White Floor Line Left 0.3 Poor
10 Km 23.4 Asphalt White Floor Line Right 0.1 Poor
11 Km 23.4 Concrete Yellow Berrier 0.1 Poor
12 Km 21.9 Asphalt White Floor Line Left -0.2 Poor
13 Km 21.9 Asphalt White Floor Line Left 0.2 Poor
14 Km 21.9 Asphalt White Floor Line Right 0.3 Poor
15 Km 21.9 Asphalt White Floor Line Right 0.3 Poor
16 Km 21.9 Asphalt White Floor Line Left 0.1 Poor
17 Km 21.9 Asphalt White Floor Line Right 0.0 Poor
18 Km 21.9 Asphalt White Floor Line Right 0.2 Poor
19 Km 16.0 Asphalt White Floor Line Left 0.2 Poor
20 Km 16.0 Asphalt White Floor Line Right 0.1 Poor
21 Km 16.0 Asphalt White Floor Line Left 0.0 Poor
LBP/ACM Sampling at PR-124 Km 23.4, 21.9, 16.0 & 2.4
Building
PR-124
PR-124
PR-124
PR-124
LEAD BASED PAINT TESTING DATA SHEET
Date:
Inspector: Carlos Carrion
PR-124
XRF Serial No.:
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
Substrate: Concrete (C), Metal (M), Wood (W),Gypsum (G) Paint Condition: Fair (F)
Project Name:
Address: Las Marias, Puerto Rico 2445
Reading # Room Substrate Color Component & Location
XRF
Reading
Paint
Condition Comments
LBP/ACM Sampling at PR-124 Km 23.4, 21.9, 16.0 & 2.4
Building
LEAD BASED PAINT TESTING DATA SHEET
Date:
Inspector: Carlos Carrion
XRF Serial No.:
22 Km 16.0 Asphalt White Floor Line Right 0.1 Poor
23 Km 16.0 Asphalt White Floor Line Left 0.0 Poor
24 Km 16.0 Asphalt White Floor Line Right 0.1 Poor
25 Km 16.0 Asphalt White Floor Line Left 0.0 Poor
26 Km 16.0 Asphalt White Floor Line Right 0.2 Poor
27 Km 16.0 Asphalt White Floor Line Left 0.0 Poor
28 Km 16.0 Asphalt White Floor Line Right -0.2 Poor
29 Km 16.0 Asphalt White Floor Line Left -0.1 Poor
30 Km 16.0 Stc. Concrete Yellow Exterior Wall A 0.0 Poor
31 Km 16.0 Stc. Concrete Lt. Yellow Exterior Wall B 0.0 Poor
32 Km 16.0 Stc. Concrete Lt. Yellow Exterior Wall C 0.0 Poor
33 Km 16.0 Stc. Concrete Lt. Yellow Exterior Wall D 0.3 Poor
34 Km 16.0 Stc. Concrete Brown Exterior Baseboard 0.0 Poor
35 Km 16.0 Stc. Concrete Brown Exterior Window Trim 0.2 Poor
36 Km 16.0 Stc. Metal White Exterior Window 0.2 Poor
37 Km 16.0 Stc. Metal White Exterior Door Frame 0.0 Poor
38 Km 16.0 Stc. Metal White Exterior Door 0.2 Poor
39 Km 2.4 Asphalt White Floor Line Right 0.0 Poor
40 Km 2.4 Asphalt White Floor Line Right 0.0 Poor
41 Km 2.4 Asphalt White Floor Line Left 0.2 Poor
42 Km 2.4 Asphalt White Floor Line Right 0.2 Poor
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
PR-124
Project Name:
Address: Las Marias, Puerto Rico 2445
Reading # Room Substrate Color Component & Location
XRF
Reading
Paint
Condition Comments
LBP/ACM Sampling at PR-124 Km 23.4, 21.9, 16.0 & 2.4
Building
LEAD BASED PAINT TESTING DATA SHEET
Date:
Inspector: Carlos Carrion
XRF Serial No.:
43 Km 2.4 Asphalt White Floor Line Left 0.3 Poor
44 Km 2.4 Asphalt White Floor Line Right 0.3 Poor
45 Km 2.4 Asphalt White Floor Line Left 0.3 Poor
46 Km 2.4 Asphalt White Floor Line Right 0.0 Poor
47 Calibration 1.0
48 Calibration 0.9
49 Calibration 1.0
PR-124
PR-124
PR-124
PR-124
At PR-124 Km 16.0 was inspected around areas of the structure as there was no access.
Family of the owner of the structure report that it was built after 1978
Jose A. Batlle & Asociados Page 14
APÉNDICE D2
EVIDENCIA PICTORICA DE LA EVALUACION PARA PLOMO (PBP)
General Photos of Project Group B – Area 1 PR-124, Km 16.0
General Photos of Project Group B – Area 2 PR-124, Km 2.40
General Photos of Project Group B – Area 3 PR-124, Km 21.9
General Photos of Project Group B – Area 4 PR-124, Km 23.4
Jose A. Batlle & Asociados Page 15
APÉNDICE D3
XRF PERFORMANCE CHARACTERISTICS SHEET
Jose A. Batlle & Asociados Page 16
Jose A. Batlle & Asociados Page 17
Jose A. Batlle & Asociados Page 18
Jose A. Batlle & Asociados Page 19
Jose A. Batlle & Asociados Page 20
APÉNDICE E-1
CERTIFICACION NEGATIVA DE PRESENCIA DE ASBESTO (MCA)
GOBIERNO DE PUERTO RICO
OFICINA DEL GOBERNADOR
JUNTA DE CALIDAD AMBIENTAL
Area de Calidad de Agua Forma PGC-009
CERTIFICACION DE NO PRESENCIA DE ASBESTO
EN ESTRUCTURAS A DEMOLERSE
(Debera completarse en letra de molde o impresa)
NUM. PERMISO:
Yo, ______________ , mayor de edad, ______ , y vecino de __________ _ (Nombre) (Municipio)
Direcci6n Postal ;
(Estado Civil)
607 Lady Di; Urb. Villa de Juan Ponce, PR 00716 (Pueblo) (Zip Code)
Telefono: Oficina (787) 504-0279 Correo Electronico: taagroup2@gmail.com
Certifico que:
1. La Estructura de Hormigon localizada en el segmento de carretera PR 124 Km 16.0 se excluye de esta certificacion.
El Segmento de Carretera PR 124 Km 16.0 (15.85 - 16.20), Las Marias, PR , la cual sera objeto de una reparacion y demolici6n se encuentra libre de asbesto.
2. La informaci6n antes indicada es cierta y correcta.
3. Afirmo y reconozco las consecuencias de incluir y someter informaci6n falsa en este documento.
4. Para que asi conste, firmo la presente certificaci6n en Ponce, de Puerto Rico, (Municipio} hoy dia 9 de Diciembre de 2019.
irma y Sello del Profesio al o Firma del Ins ector de Asbesto registrado por la JCA (Original)
Nota: lngenieros o Arquitectos deberan someter evidencia de que se encuentra al dfa en el pago de sus cuotas de colegiaci6n e lnspectores de Asbesto deberan someter evidencia de la tarjeta de registro provista por la JCA.
Direcci6n Fisica: Ave. Ponce de Leon 1308, Carr. Estatal 8838, Sector el Cinco, Rio Piedras, PR 00926
Direcci6n Postal: Apartado 11488, Santurce, PR 00910-1488
Tel. (787) 767-8181 • Fax (787} 767-1962
PUERTORKO 1111/1
VERDE�
Proyecto Num. ER-HWY-104 PR 124; Km 16.0; Desde 15.85 hasta 16.20
Adolfo Valdes Agrait Casado Ponce
ASB-0719-0482 SI
JUNTA DE CALIDAD AMBIENTAL
Area de Calidad de Agua Forma PGC-009
CERTIFICACION DE NO PRESENCIA DE ASBESTO
EN ESTRUCTURAS A DEMOLERSE
(Debera completarse en letra de molde o impresa)
NUM. PERMISO:
Yo, ______________ , mayor de edad, ______ , y vecino de __________ _ (Nombre) (Municipio)
Direcci6n Postal ;
(Estado Civil)
607 Lady Di; Urb. Villa de Juan Ponce, PR 00716 (Pueblo) (Zip Code)
Telefono: Oficina (787) 504-0279 Correo Electronico: taagroup2@gmail.com
Certifico que:
1. El Segmento de Carretera PR 124 Km 2.4 (2.3 - 2.5), Las Marias, PR, el cual sera objeto de una reparacion y demolici6n se encuentra libre de asbesto.
2. La informaci6n antes indicada es cierta y correcta.
3. Afirmo y reconozco las consecuencias de incluir y someter informaci6n falsa en este documento.
4. Para que asi conste, firmo la presente certificaci6n en Ponce, de Puerto Rico, (Municipio} hoy dia 9 de Diciembre de 2019.
irma y Sello del Profesio al o Firma del Ins ector de Asbesto registrado por la JCA (Original)
Nota: lngenieros o Arquitectos deberan someter evidencia de que se encuentra al dfa en el pago de sus cuotas de colegiaci6n e lnspectores de Asbesto deberan someter evidencia de la tarjeta de registro provista por la JCA.
Direcci6n Fisica: Ave. Ponce de Leon 1308, Carr. Estatal 8838, Sector el Cinco, Rio Piedras, PR 00926
Direcci6n Postal: Apartado 11488, Santurce, PR 00910-1488
Tel. (787) 767-8181 • Fax (787} 767-1962
PUERTORKO 1111/1
VERDE�
Proyecto Num. ER-HWY-105 PR 124; Km 2.4; Desde 2.3 hasta 2.5
JUNTA DE CALIDAD AMBIENTAL
Area de Calidad de Agua Forma PGC-009
CERTIFICACION DE NO PRESENCIA DE ASBESTO
EN ESTRUCTURAS A DEMOLERSE
(Debera completarse en letra de molde o impresa)
NUM. PERMISO:
Yo, ______________ , mayor de edad, ______ , y vecino de __________ _ (Nombre) (Municipio)
Direcci6n Postal ;
(Estado Civil)
607 Lady Di; Urb. Villa de Juan Ponce, PR 00716 (Pueblo) (Zip Code)
Telefono: Oficina (787) 504-0279 Correo Electronico: taagroup2@gmail.com
Certifico que:
1. El Segmento de Carretera PR 124 Km 21.9 (21.72 - 22.02), Las Marias, PR, el cual sera objeto de una reparacion y demolici6n se encuentra libre de asbesto.
2. La informaci6n antes indicada es cierta y correcta.
3. Afirmo y reconozco las consecuencias de incluir y someter informaci6n falsa en este documento.
4. Para que asi conste, firmo la presente certificaci6n en Ponce, de Puerto Rico, (Municipio} hoy dia 9 de Diciembre de 2019.
irma y Sello del Profesio al o Firma del Ins ector de Asbesto registrado por la JCA (Original)
Nota: lngenieros o Arquitectos deberan someter evidencia de que se encuentra al dfa en el pago de sus cuotas de colegiaci6n e lnspectores de Asbesto deberan someter evidencia de la tarjeta de registro provista por la JCA.
Direcci6n Fisica: Ave. Ponce de Leon 1308, Carr. Estatal 8838, Sector el Cinco, Rio Piedras, PR 00926
Direcci6n Postal: Apartado 11488, Santurce, PR 00910-1488
Tel. (787) 767-8181 • Fax (787} 767-1962
PUERTORKO 1111/1
VERDE�
Proyecto Num. ER-HWY-106 PR 124; Km 21.9; Desde 21.72 hasta 22.02
JUNTA DE CALIDAD AMBIENTAL
Area de Calidad de Agua Forma PGC-009
CERTIFICACION DE NO PRESENCIA DE ASBESTO
EN ESTRUCTURAS A DEMOLERSE
(Debera completarse en letra de molde o impresa)
NUM. PERMISO:
Yo, ______________ , mayor de edad, ______ , y vecino de __________ _ (Nombre) (Municipio)
Direcci6n Postal ;
(Estado Civil)
607 Lady Di; Urb. Villa de Juan Ponce, PR 00716 (Pueblo) (Zip Code)
Telefono: Oficina (787) 504-0279 Correo Electronico: taagroup2@gmail.com
Certifico que:
1. El Segmento de Carretera PR 124 Km 23.4 (23.33 - 23.53), Las Marias, PR, el cual sera objeto de una reparacion y demolici6n se encuentra libre de asbesto.
2. La informaci6n antes indicada es cierta y correcta.
3. Afirmo y reconozco las consecuencias de incluir y someter informaci6n falsa en este documento.
4. Para que asi conste, firmo la presente certificaci6n en Ponce, de Puerto Rico, (Municipio} hoy dia 9 de Diciembre de 2019.
irma y Sello del Profesio al o Firma del Ins ector de Asbesto registrado por la JCA (Original)
Nota: lngenieros o Arquitectos deberan someter evidencia de que se encuentra al dfa en el pago de sus cuotas de colegiaci6n e lnspectores de Asbesto deberan someter evidencia de la tarjeta de registro provista por la JCA.
Direcci6n Fisica: Ave. Ponce de Leon 1308, Carr. Estatal 8838, Sector el Cinco, Rio Piedras, PR 00926
Direcci6n Postal: Apartado 11488, Santurce, PR 00910-1488
Tel. (787) 767-8181 • Fax (787} 767-1962
PUERTORKO 1111/1
VERDE�
Proyecto Num. ER-HWY-108 PR 124; Km 23.4; Desde 23.33 hasta 23.53
Jose A. Batlle & Asociados Page 21
APÉNDICE E2
CERTIFICACION NEGATIVA DE PRESENCIA DE PLOMO (PBP)
| Reporte de Hallazgos-Grupo B-Apendice E1 PGC-009 MCA.pdf |
| ER-HWY-104 PGC-009 |
| ER-HWY-105 PGC-009 |
| ER-HWY-106 PGC-009 |
| ER-HWY-108 PGC-009 |
File details come from the government source that posted it. Updated .