Lead and Asbestos Report - AC-830579.pdf

PDF 3 MB Posted

Attached to
Landslide Repairs in Lares, Puerto Rico
Solicitation number
693C73-24-B-000011
Issued by

About this file

This document is a Lead and Asbestos Report for a federal contract opportunity related to landslide repairs on several highway segments in Lares, Puerto Rico.

The report summarizes the findings from an environmental assessment conducted to determine the presence of asbestos-containing materials (ACM) and lead-based paint (LBP) on PR-128, PR-124, and related highway segments. The assessment found no ACM or LBP in the evaluated areas, with the exception of a concrete structure along PR-124 Km 16.0 that could not be accessed due to safety concerns. The report includes detailed inspection data, test results, and certifications of the negative findings for ACM and LBP.

The related federal contract opportunity is for the Landslide Repairs in Lares, Puerto Rico project under Solicitation Number 693C73-24-B-000011. The overall project is expected to cost between $5,000,000 to $10,000,000 and will be split into multiple work schedules/contract options. The work includes embankment reconstruction, slope systems, walls, drainage, paving, and other repairs on the affected highway segments. Bid documents are expected to be issued on or about May 9, 2024.

View the file

Other files

File Type Posted
Results of Bid Opening - PR ER DOT PRMNT RPR(21).pdf PDF
Amendment 0003 - PR ER DOT PRMNT RPR(21).pdf PDF
Amendment 0003 - PR ER DOT PRMNT RPR(21).pdf PDF
Amendment 0002 - PR ER DOT PRMNT RPR(21).pdf PDF
Amendment 0001 - PR ER DOT PRMNT RPR(21).pdf PDF
ADV_Bidders Qualifications Form.doc DOC document
Technical Report - AC-831579_HWY-136.pdf PDF
Hydrologic-Hidraulic Analysis Report - AC-831579.pdf PDF
Lead Report - AC-901579_Hwy-107.pdf PDF
Lead Report - AC-901579_Hwy-107_Certification.pdf PDF
Utility Status Report - AC-901579.pdf PDF
Technical Report - AC-831579_HWY-134.pdf PDF
DTOPs Manual de Senales de Transito (MST).pdf PDF
Technical Report - AC-831579_HWY-135.pdf PDF
Geotechnical Report - AC-831579_Hwy-137.pdf PDF
Categorical Exclusion Form (NEPA) - Sch A_AC-831579_Hwy-133-140.pdf PDF
Hydrologic-Hidraulic Analysis Report - AC-830579_Hwy-106_Appendix B.pdf PDF
Plans - PR ER DOT PRMNT RPR(21) - Set_Sch B_AC-830579_Hwy-106_108.pdf PDF
Utility Status Report - AC-831579.pdf PDF
Geotechnical Report - AC-830579_Hwy-106.pdf PDF
PRHTAs Standard Specifications for Road and Bridge Construction.pdf PDF
PRHTAs Standard Drawings.pdf PDF
Plans - PR ER DOT PRMNT RPR(21) - Set_Sch A_AC-831579_Hwy-133-140_part 1 of 3.pdf PDF
Geotechnical Report - AC-831579_Hwy-136.pdf PDF
Asbestos Report - AC-901579_Hwy-107.pdf PDF
Hydrologic-Hidraulic Analysis Report - AC-830579_Hwy-108_Appendix C.pdf PDF
Geotechnical Report - AC-831579_Hwy-134.pdf PDF
Lead and Asbestos Report - AC-831579.pdf PDF
Technical Report - AC-830579_HWY-108.pdf PDF
USFWS Conservation Measures.pdf PDF
VETS-4212 Form.pdf PDF
Technical Report - AC-831579_HWY-133.pdf PDF
Asbestos Report - AC-901579_Hwy-107_Certification.pdf PDF
Technical Report - AC-830579_HWY-106.pdf PDF
Hydrologic-Hidraulic Analysis Report - AC-830579.pdf PDF
Geotechnical Report - AC-831579_Hwy-140.pdf PDF
Technical Report - AC-831579_HWY-140.pdf PDF
AC-901579_ LUMA Letter and Conctruction.pdf PDF
Utility Status Report - AC-830579.pdf PDF
Plans - PR ER DOT PRMNT RPR(21) - Set_Sch A_AC-831579_Hwy-133-140_part 2 of 3.pdf PDF
Technical Report - AC-901579_HWY-107.pdf PDF
Geotechnical Report - AC-831579_Hwy-135.pdf PDF
Categorical Exclusion Form (NEPA) - Sch B_AC-830579_Hwy-106_108.pdf PDF
Geotechnical Report - AC-831579_Hwy-133.pdf PDF
IFB Solicitation - PR ER DOT PRMNT RPR(21).pdf PDF
PRHTAs Material Testing Schedule.pdf PDF
PRHTAs Standard Drawings_Revised GABI Drawings_GABI 9-10.pdf PDF
Geotechnical Report - AC-830579_Hwy-108.pdf PDF
Plans - PR ER DOT PRMNT RPR(21) - Set_Sch A_AC-831579_Hwy-133-140_part 3 of 3.pdf PDF
Plans - PR ER DOT PRMNT RPR(21) - Set_Sch B_AC-901579_Hwy-107.pdf PDF
Show 40 more

Latest 50 of 52 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THE ATMOSPHERIC ASSESSMENT GROUP

Adolfo Valdés-Agrait; M. Sc. Environmental, Health and Safety Senior Partner Consultant and Training Facility P. O. Box 219 e-mail: taagroup2@gmail.com Mercedita, Puerto Rico 00715 (787) 504-0279

PROYECTO DE EVALUACIÓN Y REPARACIÓN DE

DAÑOS Y DESLIZAMIENTOS EN CARRETERA

PR 124 EN LAS MARÍAS, PUERTO RICO

PROYECTO NÚM. AC-809544

REPORTE DE HALLAZGOS PARA LA PRESENCIA DE

MATERIALES DE CONSTRUCCIÓN CON CONTENIDO DE

ASBESTO Y DE PINTURA CON BASE DE PLOMO

Preparado por: The Atmospheric Assessment Group

Preparado para: Autoridad de Carreteras y Transportación (ACT)

DICIEMBRE 2019

mailto:taagroup2@gmail.com

Jose A. Batlle & Asociados Page 2 Grupo B-Reporte de Hallazgos MCA & PBP Diciembre 2019

TABLA DE CONTENIDO

Página de Presentación 1

Tabla de Contenido 2

Certificación Profesional 3

1.0 Introducción 4

2.0 Protocolo de Evaluación 5

3.0 Resumen de Hallazgos 6

3.1 Hallazgos para Materiales con Asbesto 6

3.2 Hallazgos para Pintura con Base de Plomo 6

4.0 Conclusión del Estudio 8

5.0 Acuerdo de Confidencialidad 8

6.0 Delimitación del Estudio 8

LISTA DE TABLAS

Tabla Núm. 1- Grupo “B’; Las Marías, Puerto Rico 4

Tabla Núm. 2- Hallazgos para Material con Asbesto 7

Tabla Núm. 3- Hallazgos para Pintura con Base de Plomo 7

APÉNDICES

A Localización del Proyecto; PR-124

B Certificación de Inspectores de Asbesto y de Plomo

C-1 Resultados de la Evaluación para la Presencia de Asbesto (MCA)

C-2 Evidencia Pictórica de la Evaluación para Asbesto (MCA)

D-1 Resultados de la Evaluación para la Presencia de Plomo (PBP)

D-2 Evidencia Pictórica de la Evaluación para Plomo (PBP)

D-3 XRF Performance Characteristic Sheet

E-1 Certificación Negativa de Presencia de Asbesto (MCA)

E-2 Certificación Negativa de Presencia de Plomo (PBP)

Jose A. Batlle & Asociados Page 3

PROYECTO DE EVALUACIÓN Y REPARACIÓN DE

DAÑOS Y DESLIZAMIENTOS EN CARRETERAS

PR 124 EN LAS MARÍAS, PUERTO RICO

PROYECTO NÚM. AC-809544

REPORTE DE EVALUACIÓN AMBIENTAL PARA LA

DETERMINACIÓN DE LA PRESENCIA DE MATERIALES DE

CONSTRUCCIÓN CON CONTENIDO DE ASBESTO (MCA) Y

DE PINTURA CON BASE DE PLOMO (PBP)

CERTIFICACIÓN PROFESIONAL

Certificamos que el informe aquí presentado, para las estructuras de referencia, fue escrito de acuerdo con las guías publicadas por la Junta de Calidad

Ambiental (JCA) y las Guías publicadas por la Agencia de Protección Ambiental

Federal (APA).

Las muestras se tomaron por Inspectores certificados por ambas agencias, y siguiendo el Protocolo de Muestreo recomendado en las publicaciones descritas.

Las muestras para la determinación de Pintura con Base de Plomo fueron obtenidas mediante el uso de un Instrumento de Fluorescencia de Rayos “X”

(XRF, por sus siglas en ingles), y por inspectores certificados por la Junta de

Calidad Ambiental.

Certificamos que la descripción y localización de nuestros hallazgos, son correctos a la fecha de este informe.

Adolfo Valdés Agrait, M. Sc.

The Atmospheric Assessment Group Asbestos Inspector & Project Designer

Jose A. Batlle & Asociados Page 4

1.0 INTRODUCCIÓN

Nuestra compañía fue contratada por el Ingeniero Edwin Ortiz, en representación de la firma Jose A. Batlle & Asociados, para desarrollar una inspección a las estructuras de referencia, y determinar la presencia y la concentración de materiales de construcción con contenido de Asbesto (MCA), y de Pintura con Base de Plomo (PBP). El producto de la inspección realizada en el lugar de referencia se presenta en este Informe con nuestros hallazgos y los resultados de las muestras tomadas.

El día 26 de Noviembre de 2019 visitamos las carreteras descritas en la Orden de

Proceder-Grupo “B”; y se levantaron los datos que aquí se describen. Las muestras se tomaron por inspectores de Asbesto y de Plomo, certificados por la Junta de Calidad

Ambiental, JCA (Apéndice A). Las muestras para la determinación de la presencia de plomo en pintura se tomaron mediante el uso de un instrumento conocido como “XRF”, (X-Ray Fluorescence, por sus siglas en ingles), y por un Inspector certificado por la

JCA. Los datos analíticos presentados cumplieron con los requisitos del Programa de

Control de Calidad del laboratorio de referencia.

Tabla Núm. 1 Grupo B; Las Marías, Puerto Rico

Proyecto Municipio Carretera y Km Extensión del Estudio Área de Estudio

ER-HWY-104 Las Marías PR 124-Km 16.0 Desde: Km 15.85 Hasta: 16.20 Aprox. 9,400 M2

ER-HWY-105 Las Marías PR 124-Km 2.4 Desde: Km 2.3 Hasta: 2.5 Aprox. 2,700 M2

ER-HWY-106 Las Marías PR 124-Km 21.9 Desde: Km 21.72 Hasta: 22.02 Aprox. 4,500 M2

ER-HWY-108 Las Marías PR 124-Km 23.4 Desde: Km 23.33 Hasta: 23.53 Aprox. 2,200 M2

Los hallazgos del estudio se presentan a continuación.

Jose A. Batlle & Asociados Page 5

2.0 PROTOCOLO DE EVALUACIÓN

La evaluación se desarrolló con el propósito de identificar las necesidades de la

Autoridad de Carreteras en el proceso de reparación de los segmentos de las carreteras que sufrieron daños y deslizamientos causados por los Huracanes Irma y

María.

Nuestra contribución al proyecto consistió en las visitas a los segmentos de carreteras descritos, el reconocimiento, investigación, y evaluación de componentes potenciales a contener Materiales de Construcción con Contenido de Asbesto, y de Pintura con Base de Plomo, análisis de las muestras obtenidas por métodos aceptados y en cumplimiento con las agencias reguladoras estatales y federales, y la preparación de

Reporte de Hallazgos del Estudio.

La cantidad de muestras obtenidas, la selección de la localización de los puntos de muestreo, y la frecuencia de las muestras, se basó en el objetivo del estudio. Se preservaron las guías de muestreo publicadas por las agencias reguladoras, y la presunción de que materiales similares en la misma área, son considerados como homogéneos. Durante la evaluación, inspeccionamos todos los materiales identificados en los segmentos de carreteras, que pudieran contener mineral de asbesto y pintura con base de plomo.

Jose A. Batlle & Asociados Page 6

3.0 RESUMEN DE HALLAZGOS

Nuestro reporte ha sido organizado de forma consistente con las guías publicadas por las agencias reguladoras. La inspección y evaluación se desarrolló siguiendo las guías actualizadas para la determinación de la presencia y la concentración de materiales sospechosos de contener Material con Contenido de Asbesto (MCA) y de Pintura con

Base de Plomo (PBP), según las definiciones publicadas por la Agencia de Protección

Ambiental Federal (EPA, por sus siglas en ingles), y por la Junta de Calidad Ambiental

(JCA).

Se tomaron muestras representativas de todos los componentes y sustratos de los segmentos de carretera con potencial de contener los materiales regulados.

3.1 Hallazgos para los Materiales con Contenido de Asbesto (MCA)

Durante nuestra investigación de campo, y visitas a los diferentes segmentos de carreteras, no se identificó ningún material con potencial de contener minerales de asbesto. No se identificó Material de Aislación Termal, ni Material de Superficie, ni

Material Misceláneo en las areas evaluadas. Por lo tanto, se emite un Certificación de

No Presencia de Asbesto en los segmentos de carreteras identificados bajo el Grupo

“B”. Se excluye de la certificación le estructura de hormigón ubicada en el segmento

PR-124 Km 16.0, de la cual no tuvimos acceso por considerarse en riesgo de deslizamiento. El Apéndice C contiene la Evaluación de Campo para MCA.

3.2 Hallazgos para la Pintura con Base de Plomo (PBP)

La pintura con base de plomo se define como aquella pintura, capa o barniz que contiene más de 1.0 mg/cm2 de plomo, medido con un XRF. Las lecturas obtenidas demuestran que no existe PBP en los segmentos de carreteras evaluadas. Por lo tanto, se emite una Certificación de NO Presencia de Pintura con Base de Plomo en los segmentos de carreteras evaluados.

Jose A. Batlle & Asociados Page 7

Los hallazgos se presentan en la Tabla Núm. 3. El Apéndice D-1 contiene la Evaluación de Campo para las áreas evaluadas para PBP. Se excluye de la certificación le estructura de hormigón ubicada en el segmento PR-124 Km 16.0, de la cual no tuvimos acceso por considerarse en riesgo de deslizamiento.

Tabla Núm. 2 Hallazgos de la Presencia de Material con Contenido de Asbesto (MCA).

Proyecto Carretera y Km Extensión del Estudio Área de Estudio Contenido de

Asbesto

ER-HWY-104 PR 124-Km 16.0 Desde: Km 15.85 Hasta: 16.20 Aprox. 9,400 M2 No se determinó presencia de materiales con potencial de contener Minerales de

Asbesto

ER-HWY-105 PR 124-Km 2.4 Desde: Km 2.3 Hasta: 2.5 Aprox. 2,700 M2

ER-HWY-106 PR 124-Km 21.9 Desde: Km 21.72 Hasta: 22.02 Aprox. 4,500 M2

ER-HWY-108 PR 124-Km 23.4 Desde: Km 23.33 Hasta: 23.53 Aprox. 2,200 M2

Se emite una Certificación de No Presencia de Material con Contenido de

Asbesto (MCA) para los segmentos de las Carreteras en el Grupo “B”, en Las

Marías, Puerto Rico. Se excluye estructure de hormigón en el tramo de carretera.

Tabla Núm. 3 Hallazgos de la Presencia de Pintura con Base de

Plomo (PBP).

Proyecto Carretera y Km Extensión del Estudio Área de Estudio Contenido de

Plomo

ER-HWY-104 PR 124-Km 16.0 Desde: Km 15.85 Hasta: 16.20 Aprox. 9,400 M2 No se determinó presencia de PBP en las muestras obtenidas.

ER-HWY-105 PR 124-Km 2.4 Desde: Km 2.3 Hasta: 2.5 Aprox. 2,700 M2

ER-HWY-106 PR 124-Km 21.9 Desde: Km 21.72 Hasta: 22.02 Aprox. 4,500 M2

ER-HWY-108 PR 124-Km 23.4 Desde: Km 23.33 Hasta: 23.53 Aprox. 2,200 M2

Se emite una Certificación de No Presencia de Pintura en Base de Plomo (PBP) para los segmentos de las Carreteras en el Grupo “B”, en Las Marías, Puerto Rico.

Se excluye estructura de hormigón en el tramo de carretera.

Jose A. Batlle & Asociados Page 8

4.0 CONCLUSIÓN

Los resultados de nuestra evaluación de campo, la confirmación de la ausencia de materiales con el potencial de contener minerales de asbesto y los análisis de las muestras para la determinación de la presencia de Pintura con Plomo, demuestran que los segmentos de las carreteras, identificados como Grupo “B”, no contienen Materiales de Construcción con Contenido de Asbesto (MCA), ni Pintura en Base de Plomo (PBP).

Por lo tanto, se emite una “Certificación de Hallazgos Negativos para la presencia de MCA y una “Certificación de Hallazgos Negativos para la presencia de PBP” para todos los segmentos identificados en las carreteras PR-124, en Las Marías, Puerto Rico.

5.0 CONFIDENCIALIDAD

Los datos generados durante nuestra evaluación, los hallazgos y resultados de análisis de las muestras, se mantienen como información privilegiada y confidencial. Ninguno de estos datos será revelado, examinado o compartido con personas ajenas al proyecto.

Solamente, y mediante autorización escrita por el titular del proyecto, se entregará copia de este informe.

6.0 DELIMITACIÓN DEL ESTUDIO

Nuestro estudio se limita a los segmentos de carreteras, según descritos como Grupo

“B” en la Tabla Núm. 1, página 4, y a la fecha del informe. Nuestra empresa no garantiza que la condición del material identificado y descrito se mantendrá en la condición encontrada.

Adolfo Valdés Agrait, M. Sc.

Jose A. Batlle & Asociados Page 9

APÉNDICE A

CERTIFICACIÓN DE LOS INSPECTORES DE ASBESTO Y PLOMO

Jose A. Batlle & Asociados Page 2 Grupo B-Reporte de Hallazgos MCA & PBP Noviembre 20019

Jose A. Batlle & Asociados Page 10

APÉNDICE B

LOCALIZACIÓN DEL PROYECTO: PR-124

PROJECT GROUP B

Area 1-ER-HWY-104 Las Marias, PR- 124 Km 16.0 (15.85 to 16.20) (X= 149,460.308, Y=244,648.091); 9400 M2

Area 2-ER-HWY-105 Las Marias, PR-124 Km 2.4 (2.3-2.5) (X= 142,429.971, Y=245,618.494); 2,700 M2

Area 3-ER-HWY-106 Las Marias, PR-124 Km 21.9 (21.72-22.02) (X= 150,375.597, Y=248,156.713); 4,500 M2

Area 4- ER-HWY-108 Las Marias, PR-124 Km 23.4 (23.33-23.53) (X= 151,161.452, Y=248,772.991); 2,200 M2

ER-HWY-104 Las Marias, PR-124 Km 16.0 (15.85 to 16.20)

ER-HWY-106 Las Marias, PR-124 Km 21.9 (21.72-22.02)

ER-HWY-108 Las Marias, PR-124 Km 23.4 (23.33-23.53)

ER-HWY-105 Las Marias, PR-124 Km 2.4 (2.3-2.5)

Jose A. Batlle & Asociados Page 11

APÉNDICE C1

EVALUACION PARA LA PRESENCIA DE ASBESTO (MCA)

ASBESTOS CONTAINING MATERIAL INSPECTION SHEET

Contratista: José A. Batlle & Asociados, C. S. P.

Localización del Proyecto: Las Marías, Puerto Rico Lugar de Inspección: ER-HWY-104; PR-124; Km. 16.0

Desde Km 15.85 hasta Km 16.20; +/- 9,400 M3

ACM TYPE Present Condition

(G-F-P)

Disturbance Potential (L-M-H)

Area Covered

Notes

Thermal System Insulation

-Tank Insulation No NA NA NA No Aplica

-Pipe Insulation No NA NA NA No Aplica

-Elbow/Fitting/Valve Insulation No NA NA NA No Aplica

-Boiler Insulation No NA NA NA No Aplica

-Duct Insulation No NA NA NA No Aplica

-Cement/Patching Compound No NA NA NA No Aplica

Surfacing Material

-Stucco/Plaster No NA NA NA No Aplica

-Spray-applied Fireproofing No NA NA NA No Aplica

-Surface Coating (Popcorn Ceiling) No NA NA NA No Aplica

-Acoustical/Decorative Surface No NA NA NA No Aplica

Miscellaneous Material

-Vinyl Floor Tiles (VFT)/Linoleum Not Checked NA NA NA No Aplica

-Mastic for Flooring Not Checked NA NA NA No Aplica

-Window Caulking Not Checked NA NA NA No Aplica

-Door Frame Caulking Not Checked NA NA NA No Aplica

-Joint Compound No NA NA NA No Aplica

-Fire Doors No NA NA NA No Aplica

-Vibration Dampening Cloths No NA NA NA No Aplica

-Ceiling Tiles No NA NA NA No Aplica

-Asphalt Roofing No NA NA NA No Aplica

-Transite (Asbestos-Cement) Panels No NA NA NA No Aplica

-Shingles No NA NA NA No Aplica

Documentos del Proyecto

Adolfo Valdés-Agrait, M. Sc. 1-Foto del frente de la Estructura

2-Direccion Física de la Estructura

Fecha: 30 de Noviembre de 2019 3-Plano de la Estructura

4-Marcar Plano con Puntos de Muestreo

Nota: Por razones de seguridad no se pudo entrar a la residencia; 5-Evidencia Pictórica de Puntos de Muestreo

Se encuentra en riesgo de deslizamiento. 6-Cantidad o Volumen de MCA (estimado)

TAAG-ACBM Form 2016-01; Mod. 14 Nov 2019 7-Cadena de Custodia

Localización del Proyecto: Las Marías, Puerto Rico Lugar de Inspección: ER-HWY-105; PR-124; Km. 2.4

Desde Km 2.3 hasta Km 2.5; +/- 2,700 M3

(G-F-P)

Disturbance Potential (L-M-H)

Area

-Pipe Insulation No NA NA NA No Aplica

-Elbow/Fitting/Valve Insulation No NA NA NA No Aplica

-Boiler Insulation No NA NA NA No Aplica

-Duct Insulation No NA NA NA No Aplica

-Cement/Patching Compound No NA NA NA No Aplica

Surfacing Material

-Stucco/Plaster No NA NA NA No Aplica

-Spray-applied Fireproofing No NA NA NA No Aplica

-Surface Coating (Popcorn Ceiling) No NA NA NA No Aplica

-Acoustical/Decorative Surface No NA NA NA No Aplica

Miscellaneous Material

-Vinyl Floor Tiles (VFT)/Linoleum No NA NA NA No Aplica

-Mastic for Flooring No NA NA NA No Aplica

-Window Caulking No NA NA NA No Aplica

-Door Frame Caulking No NA NA NA No Aplica

-Joint Compound No NA NA NA No Aplica

-Fire Doors No NA NA NA No Aplica

-Vibration Dampening Cloths No NA NA NA No Aplica

-Ceiling Tiles No NA NA NA No Aplica

-Asphalt Roofing No NA NA NA No Aplica

-Transite (Asbestos-Cement) Panels No NA NA NA No Aplica

-Shingles No NA NA NA No Aplica

Documentos del Proyecto

Adolfo Valdés-Agrait, M. Sc. 1-Foto del frente de la Estructura

2-Direccion Física de la Estructura

Fecha: 30 de Noviembre de 2019 3-Plano de la Estructura

4-Marcar Plano con Puntos de Muestreo 5-Evidencia Pictórica de Puntos de Muestreo

6-Cantidad o Volumen de MCA (estimado)

Localización del Proyecto: Las Marías, Puerto Rico Lugar de Inspección: ER-HWY-106; PR-124; Km. 21.9

Desde Km 21.72 hasta Km 22.02; +/- 4,500 M3

(G-F-P)

Disturbance Potential (L-M-H)

Area

-Pipe Insulation No NA NA NA No Aplica

-Elbow/Fitting/Valve Insulation No NA NA NA No Aplica

-Boiler Insulation No NA NA NA No Aplica

-Duct Insulation No NA NA NA No Aplica

-Cement/Patching Compound No NA NA NA No Aplica

Surfacing Material

-Stucco/Plaster No NA NA NA No Aplica

-Spray-applied Fireproofing No NA NA NA No Aplica

-Surface Coating (Popcorn Ceiling) No NA NA NA No Aplica

-Acoustical/Decorative Surface No NA NA NA No Aplica

Miscellaneous Material

-Vinyl Floor Tiles (VFT)/Linoleum No NA NA NA No Aplica

-Mastic for Flooring No NA NA NA No Aplica

-Window Caulking No NA NA NA No Aplica

-Door Frame Caulking No NA NA NA No Aplica

-Joint Compound No NA NA NA No Aplica

-Fire Doors No NA NA NA No Aplica

-Vibration Dampening Cloths No NA NA NA No Aplica

-Ceiling Tiles No NA NA NA No Aplica

-Asphalt Roofing No NA NA NA No Aplica

-Transite (Asbestos-Cement) Panels No NA NA NA No Aplica

-Shingles No NA NA NA No Aplica

Documentos del Proyecto

Adolfo Valdés-Agrait, M. Sc. 1-Foto del frente de la Estructura

2-Direccion Física de la Estructura

Fecha: 30 de Noviembre de 2019 3-Plano de la Estructura

4-Marcar Plano con Puntos de Muestreo 5-Evidencia Pictórica de Puntos de Muestreo

Localización del Proyecto: Las Marías, Puerto Rico Lugar de Inspección: ER-HWY-108; PR-124; Km. 23.4

Desde Km 23.33 hasta Km 23.53; +/- 2,200 M3

(G-F-P)

Disturbance Potential (L-M-H)

Area

-Pipe Insulation No NA NA NA No Aplica

-Elbow/Fitting/Valve Insulation No NA NA NA No Aplica

-Boiler Insulation No NA NA NA No Aplica

-Duct Insulation No NA NA NA No Aplica

-Cement/Patching Compound No NA NA NA No Aplica

Surfacing Material

-Stucco/Plaster No NA NA NA No Aplica

-Spray-applied Fireproofing No NA NA NA No Aplica

-Surface Coating (Popcorn Ceiling) No NA NA NA No Aplica

-Acoustical/Decorative Surface No NA NA NA No Aplica

Miscellaneous Material

-Vinyl Floor Tiles (VFT)/Linoleum No NA NA NA No Aplica

-Mastic for Flooring No NA NA NA No Aplica

-Window Caulking No NA NA NA No Aplica

-Door Frame Caulking No NA NA NA No Aplica

-Joint Compound No NA NA NA No Aplica

-Fire Doors No NA NA NA No Aplica

-Vibration Dampening Cloths No NA NA NA No Aplica

-Ceiling Tiles No NA NA NA No Aplica

-Asphalt Roofing No NA NA NA No Aplica

-Transite (Asbestos-Cement) Panels No NA NA NA No Aplica

-Shingles No NA NA NA No Aplica

Documentos del Proyecto

Adolfo Valdés-Agrait, M. Sc. 1-Foto del frente de la Estructura

2-Direccion Física de la Estructura

Fecha: 30 de Noviembre de 2019 3-Plano de la Estructura

4-Marcar Plano con Puntos de Muestreo 5-Evidencia Pictórica de Puntos de Muestreo

Jose A. Batlle & Asociados Page 12

APÉNDICE C2

EVIDENCIA PICTORICA DE LA EVALUACION PARA ASBESTO (MCA)

General Photos of Project Group B – Area 1 PR-124, Km 16.0

General Photos of Project Group B – Area 2 PR-124, Km 2.40

General Photos of Project Group B – Area 3 PR-124, Km 21.9

General Photos of Project Group B – Area 4 PR-124, Km 23.4

Jose A. Batlle & Asociados Page 13

APÉNDICE D1

EVALUACION PARA LA PRESENCIA DE PLOMO (PBP)

Client Name: 11/30/19

Project Name:

Address: Las Marias, Puerto Rico 2445

Reading # Room Substrate Color Component & Location

XRF

Reading

Paint

Condition Comments

1 Calibración 1.0

2 Calibración 1.1

3 Calibración 1.0

4 Km 23.4 Asphalt White Floor Line Left 0.2 Poor

5 Km 23.4 Asphalt White Floor Line Right -0.1 Poor

6 Km 23.4 Asphalt White Floor Line Left -0.2 Poor

7 Km 23.4 Asphalt White Floor Line Right 0.0 Poor

8 Km 23.4 Asphalt White Floor Line Right 0.1 Poor

9 Km 23.4 Asphalt White Floor Line Left 0.3 Poor

10 Km 23.4 Asphalt White Floor Line Right 0.1 Poor

11 Km 23.4 Concrete Yellow Berrier 0.1 Poor

12 Km 21.9 Asphalt White Floor Line Left -0.2 Poor

13 Km 21.9 Asphalt White Floor Line Left 0.2 Poor

14 Km 21.9 Asphalt White Floor Line Right 0.3 Poor

15 Km 21.9 Asphalt White Floor Line Right 0.3 Poor

16 Km 21.9 Asphalt White Floor Line Left 0.1 Poor

17 Km 21.9 Asphalt White Floor Line Right 0.0 Poor

18 Km 21.9 Asphalt White Floor Line Right 0.2 Poor

19 Km 16.0 Asphalt White Floor Line Left 0.2 Poor

20 Km 16.0 Asphalt White Floor Line Right 0.1 Poor

21 Km 16.0 Asphalt White Floor Line Left 0.0 Poor

LBP/ACM Sampling at PR-124 Km 23.4, 21.9, 16.0 & 2.4

Building

PR-124

PR-124

PR-124

PR-124

LEAD BASED PAINT TESTING DATA SHEET

Date:

Inspector: Carlos Carrion

PR-124

XRF Serial No.:

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

Substrate: Concrete (C), Metal (M), Wood (W),Gypsum (G) Paint Condition: Fair (F)

Project Name:

Address: Las Marias, Puerto Rico 2445

Reading # Room Substrate Color Component & Location

XRF

Reading

Paint

Condition Comments

LBP/ACM Sampling at PR-124 Km 23.4, 21.9, 16.0 & 2.4

Building

LEAD BASED PAINT TESTING DATA SHEET

Date:

Inspector: Carlos Carrion

XRF Serial No.:

22 Km 16.0 Asphalt White Floor Line Right 0.1 Poor

23 Km 16.0 Asphalt White Floor Line Left 0.0 Poor

24 Km 16.0 Asphalt White Floor Line Right 0.1 Poor

25 Km 16.0 Asphalt White Floor Line Left 0.0 Poor

26 Km 16.0 Asphalt White Floor Line Right 0.2 Poor

27 Km 16.0 Asphalt White Floor Line Left 0.0 Poor

28 Km 16.0 Asphalt White Floor Line Right -0.2 Poor

29 Km 16.0 Asphalt White Floor Line Left -0.1 Poor

30 Km 16.0 Stc. Concrete Yellow Exterior Wall A 0.0 Poor

31 Km 16.0 Stc. Concrete Lt. Yellow Exterior Wall B 0.0 Poor

32 Km 16.0 Stc. Concrete Lt. Yellow Exterior Wall C 0.0 Poor

33 Km 16.0 Stc. Concrete Lt. Yellow Exterior Wall D 0.3 Poor

34 Km 16.0 Stc. Concrete Brown Exterior Baseboard 0.0 Poor

35 Km 16.0 Stc. Concrete Brown Exterior Window Trim 0.2 Poor

36 Km 16.0 Stc. Metal White Exterior Window 0.2 Poor

37 Km 16.0 Stc. Metal White Exterior Door Frame 0.0 Poor

38 Km 16.0 Stc. Metal White Exterior Door 0.2 Poor

39 Km 2.4 Asphalt White Floor Line Right 0.0 Poor

40 Km 2.4 Asphalt White Floor Line Right 0.0 Poor

41 Km 2.4 Asphalt White Floor Line Left 0.2 Poor

42 Km 2.4 Asphalt White Floor Line Right 0.2 Poor

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

PR-124

Project Name:

Address: Las Marias, Puerto Rico 2445

Reading # Room Substrate Color Component & Location

XRF

Reading

Paint

Condition Comments

LBP/ACM Sampling at PR-124 Km 23.4, 21.9, 16.0 & 2.4

Building

LEAD BASED PAINT TESTING DATA SHEET

Date:

Inspector: Carlos Carrion

XRF Serial No.:

43 Km 2.4 Asphalt White Floor Line Left 0.3 Poor

44 Km 2.4 Asphalt White Floor Line Right 0.3 Poor

45 Km 2.4 Asphalt White Floor Line Left 0.3 Poor

46 Km 2.4 Asphalt White Floor Line Right 0.0 Poor

47 Calibration 1.0

48 Calibration 0.9

49 Calibration 1.0

PR-124

PR-124

PR-124

PR-124

At PR-124 Km 16.0 was inspected around areas of the structure as there was no access.

Family of the owner of the structure report that it was built after 1978

Jose A. Batlle & Asociados Page 14

APÉNDICE D2

EVIDENCIA PICTORICA DE LA EVALUACION PARA PLOMO (PBP)

General Photos of Project Group B – Area 1 PR-124, Km 16.0

General Photos of Project Group B – Area 2 PR-124, Km 2.40

General Photos of Project Group B – Area 3 PR-124, Km 21.9

General Photos of Project Group B – Area 4 PR-124, Km 23.4

Jose A. Batlle & Asociados Page 15

APÉNDICE D3

XRF PERFORMANCE CHARACTERISTICS SHEET

Jose A. Batlle & Asociados Page 16

Jose A. Batlle & Asociados Page 17

Jose A. Batlle & Asociados Page 18

Jose A. Batlle & Asociados Page 19

Jose A. Batlle & Asociados Page 20

APÉNDICE E-1

CERTIFICACION NEGATIVA DE PRESENCIA DE ASBESTO (MCA)

GOBIERNO DE PUERTO RICO

OFICINA DEL GOBERNADOR

JUNTA DE CALIDAD AMBIENTAL

Area de Calidad de Agua Forma PGC-009

CERTIFICACION DE NO PRESENCIA DE ASBESTO

EN ESTRUCTURAS A DEMOLERSE

(Debera completarse en letra de molde o impresa)

NUM. PERMISO:

Yo, ______________ , mayor de edad, ______ , y vecino de __________ _ (Nombre) (Municipio)

Direcci6n Postal ;

(Estado Civil)

607 Lady Di; Urb. Villa de Juan Ponce, PR 00716 (Pueblo) (Zip Code)

Telefono: Oficina (787) 504-0279 Correo Electronico: taagroup2@gmail.com

Certifico que:

1. La Estructura de Hormigon localizada en el segmento de carretera PR 124 Km 16.0 se excluye de esta certificacion.

El Segmento de Carretera PR 124 Km 16.0 (15.85 - 16.20), Las Marias, PR , la cual sera objeto de una reparacion y demolici6n se encuentra libre de asbesto.

2. La informaci6n antes indicada es cierta y correcta.

3. Afirmo y reconozco las consecuencias de incluir y someter informaci6n falsa en este documento.

4. Para que asi conste, firmo la presente certificaci6n en Ponce, de Puerto Rico, (Municipio} hoy dia 9 de Diciembre de 2019.

irma y Sello del Profesio al o Firma del Ins ector de Asbesto registrado por la JCA (Original)

Nota: lngenieros o Arquitectos deberan someter evidencia de que se encuentra al dfa en el pago de sus cuotas de colegiaci6n e lnspectores de Asbesto deberan someter evidencia de la tarjeta de registro provista por la JCA.

Direcci6n Fisica: Ave. Ponce de Leon 1308, Carr. Estatal 8838, Sector el Cinco, Rio Piedras, PR 00926

Direcci6n Postal: Apartado 11488, Santurce, PR 00910-1488

Tel. (787) 767-8181 • Fax (787} 767-1962

PUERTORKO 1111/1

VERDE�

Proyecto Num. ER-HWY-104 PR 124; Km 16.0; Desde 15.85 hasta 16.20

Adolfo Valdes Agrait Casado Ponce

ASB-0719-0482 SI

JUNTA DE CALIDAD AMBIENTAL

Area de Calidad de Agua Forma PGC-009

CERTIFICACION DE NO PRESENCIA DE ASBESTO

EN ESTRUCTURAS A DEMOLERSE

(Debera completarse en letra de molde o impresa)

NUM. PERMISO:

Yo, ______________ , mayor de edad, ______ , y vecino de __________ _ (Nombre) (Municipio)

Direcci6n Postal ;

(Estado Civil)

607 Lady Di; Urb. Villa de Juan Ponce, PR 00716 (Pueblo) (Zip Code)

Telefono: Oficina (787) 504-0279 Correo Electronico: taagroup2@gmail.com

Certifico que:

1. El Segmento de Carretera PR 124 Km 2.4 (2.3 - 2.5), Las Marias, PR, el cual sera objeto de una reparacion y demolici6n se encuentra libre de asbesto.

2. La informaci6n antes indicada es cierta y correcta.

3. Afirmo y reconozco las consecuencias de incluir y someter informaci6n falsa en este documento.

4. Para que asi conste, firmo la presente certificaci6n en Ponce, de Puerto Rico, (Municipio} hoy dia 9 de Diciembre de 2019.

irma y Sello del Profesio al o Firma del Ins ector de Asbesto registrado por la JCA (Original)

Nota: lngenieros o Arquitectos deberan someter evidencia de que se encuentra al dfa en el pago de sus cuotas de colegiaci6n e lnspectores de Asbesto deberan someter evidencia de la tarjeta de registro provista por la JCA.

Direcci6n Fisica: Ave. Ponce de Leon 1308, Carr. Estatal 8838, Sector el Cinco, Rio Piedras, PR 00926

Direcci6n Postal: Apartado 11488, Santurce, PR 00910-1488

Tel. (787) 767-8181 • Fax (787} 767-1962

PUERTORKO 1111/1

VERDE�

Proyecto Num. ER-HWY-105 PR 124; Km 2.4; Desde 2.3 hasta 2.5

JUNTA DE CALIDAD AMBIENTAL

Area de Calidad de Agua Forma PGC-009

CERTIFICACION DE NO PRESENCIA DE ASBESTO

EN ESTRUCTURAS A DEMOLERSE

(Debera completarse en letra de molde o impresa)

NUM. PERMISO:

Yo, ______________ , mayor de edad, ______ , y vecino de __________ _ (Nombre) (Municipio)

Direcci6n Postal ;

(Estado Civil)

607 Lady Di; Urb. Villa de Juan Ponce, PR 00716 (Pueblo) (Zip Code)

Telefono: Oficina (787) 504-0279 Correo Electronico: taagroup2@gmail.com

Certifico que:

1. El Segmento de Carretera PR 124 Km 21.9 (21.72 - 22.02), Las Marias, PR, el cual sera objeto de una reparacion y demolici6n se encuentra libre de asbesto.

2. La informaci6n antes indicada es cierta y correcta.

3. Afirmo y reconozco las consecuencias de incluir y someter informaci6n falsa en este documento.

4. Para que asi conste, firmo la presente certificaci6n en Ponce, de Puerto Rico, (Municipio} hoy dia 9 de Diciembre de 2019.

irma y Sello del Profesio al o Firma del Ins ector de Asbesto registrado por la JCA (Original)

Nota: lngenieros o Arquitectos deberan someter evidencia de que se encuentra al dfa en el pago de sus cuotas de colegiaci6n e lnspectores de Asbesto deberan someter evidencia de la tarjeta de registro provista por la JCA.

Direcci6n Fisica: Ave. Ponce de Leon 1308, Carr. Estatal 8838, Sector el Cinco, Rio Piedras, PR 00926

Direcci6n Postal: Apartado 11488, Santurce, PR 00910-1488

Tel. (787) 767-8181 • Fax (787} 767-1962

PUERTORKO 1111/1

VERDE�

Proyecto Num. ER-HWY-106 PR 124; Km 21.9; Desde 21.72 hasta 22.02

JUNTA DE CALIDAD AMBIENTAL

Area de Calidad de Agua Forma PGC-009

CERTIFICACION DE NO PRESENCIA DE ASBESTO

EN ESTRUCTURAS A DEMOLERSE

(Debera completarse en letra de molde o impresa)

NUM. PERMISO:

Yo, ______________ , mayor de edad, ______ , y vecino de __________ _ (Nombre) (Municipio)

Direcci6n Postal ;

(Estado Civil)

607 Lady Di; Urb. Villa de Juan Ponce, PR 00716 (Pueblo) (Zip Code)

Telefono: Oficina (787) 504-0279 Correo Electronico: taagroup2@gmail.com

Certifico que:

1. El Segmento de Carretera PR 124 Km 23.4 (23.33 - 23.53), Las Marias, PR, el cual sera objeto de una reparacion y demolici6n se encuentra libre de asbesto.

2. La informaci6n antes indicada es cierta y correcta.

3. Afirmo y reconozco las consecuencias de incluir y someter informaci6n falsa en este documento.

4. Para que asi conste, firmo la presente certificaci6n en Ponce, de Puerto Rico, (Municipio} hoy dia 9 de Diciembre de 2019.

irma y Sello del Profesio al o Firma del Ins ector de Asbesto registrado por la JCA (Original)

Nota: lngenieros o Arquitectos deberan someter evidencia de que se encuentra al dfa en el pago de sus cuotas de colegiaci6n e lnspectores de Asbesto deberan someter evidencia de la tarjeta de registro provista por la JCA.

Direcci6n Fisica: Ave. Ponce de Leon 1308, Carr. Estatal 8838, Sector el Cinco, Rio Piedras, PR 00926

Direcci6n Postal: Apartado 11488, Santurce, PR 00910-1488

Tel. (787) 767-8181 • Fax (787} 767-1962

PUERTORKO 1111/1

VERDE�

Proyecto Num. ER-HWY-108 PR 124; Km 23.4; Desde 23.33 hasta 23.53

Jose A. Batlle & Asociados Page 21

APÉNDICE E2

CERTIFICACION NEGATIVA DE PRESENCIA DE PLOMO (PBP)

Reporte de Hallazgos-Grupo B-Apendice E1 PGC-009 MCA.pdf
ER-HWY-104 PGC-009
ER-HWY-105 PGC-009
ER-HWY-106 PGC-009
ER-HWY-108 PGC-009

File details come from the government source that posted it. Updated .