J7 CEUC USCG APPROVED EQUIPMENT ENROLLMENT CATALOG.pdf

PDF 278 KB Posted

Attached to
Building and Site Repairs at USCG SFO Fort Macon, NC
Solicitation number
70Z08321BPAC13100
Issued by

About this file

This document outlines an invitation for bid for building and site repair services at a US Coast Guard facility in North Carolina. The solicitation is set aside for eligible 8(a) small businesses and has an estimated value between $5-10 million. Contractors must provide all labor, materials, equipment and supervision to complete repairs in accordance with specifications dated March 2021. The prevailing wage requirements apply to this project. Bids are due by a specified date and time in March 2022 and must be delivered to the contracting office. A bid bond of 20% is required. The document also provides instructions for attending a mandatory site visit and submitting any requests for information.

View the file

Other files

File Type Posted
21PAC131 Abstract of Offers Construction.pdf PDF
J13 Section 05 51 00 Metal Stairs.pdf PDF
J11 Section 31 31 16.13 Chemical Termite Control.pdf PDF
J12 Section 31 31 16.19 termite Control Barriers.pdf PDF
J10 Site Visit Sign In Sheet March 22 2022.pdf PDF
J15 C8601 D Pre alteration Hazardous Materials Survey Report REV.pdf PDF
Amend 3 Q A 21PAC131 pg 2 to 10.pdf PDF
J9 Site Visit Sign In Sheet March 15 2022.pdf PDF
J14 Section 05 52 00 Metal Railings.pdf PDF
Amend Three 21PAC131 SF30-16.pdf PDF
Amend Two 21PAC131 SF30-16 032822.pdf PDF
Amend One 21PAC131 SF30-16.pdf PDF
Amend One pg 2 to 4 031622.pdf PDF
J2 Specifications PN 11731512.pdf PDF
J7 CEUC EQUIPMENT ENROLLMENT FORM.xlsx XLSX spreadsheet
J4 C7003 - Reference DWG 6.pdf PDF
J3 C8601-D Sheets 16-30 of 134.pdf PDF
J3 C8601-D Sheets 31-45 of 134.pdf PDF
J4 C8540 - Reference DWG 10.pdf PDF
J3 C8601-D Sheets 76-90 of 134.pdf PDF
J1 SF1442 21PAC131 022822.pdf PDF
J5 WD NC20220069 02252022.PDF PDF
J4 C7219 - Reference DWG 7.pdf PDF
J3 C8601-D Sheets 121-134 of 134.pdf PDF
J3 C8601-D Sheets 91-105 of 134.pdf PDF
J8 Contractor_Responsibility_Questionair_-_New.rtf RTF text file
J4 C8316 - Reference DWG 9.pdf PDF
J1 21PAC131 IFB pages 3 to 53.pdf PDF
J4 C8600-D - Reference DWG 11.pdf PDF
J3 C8601-D Sheet 106 of 134.pdf PDF
J3 C8601-D Sheets 107-120 of 134.pdf PDF
J3 C8601-D Sheets 1-15 of 134.pdf PDF
J4 C3840 - Reference DWG 2.pdf PDF
J4 C6646 - Reference DWG 3.pdf PDF
J3 C8601-D Sheets 46-60 of 134.pdf PDF
J4 C050385 - Reference 1.pdf PDF
J4 C7943 DWG SET Reference DWG 8.pdf PDF
J5 WD NC20220062 02252022.PDF PDF
J4 C6875 - Reference DWG 5.pdf PDF
J7 C8601-D CZMA Consistency Letter.pdf PDF
J3 C8601-D sheets 61-75 of 134.pdf PDF
J6 RFI 21PAC131.docx DOCX document
J4 C6827 - Reference DWG 4.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Spec Section 01 80 00 USCG Approved Equipment Enrollment Catalog - Existing SAM Maintained Equipment*

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life

B203003 REVOLVING DOORS Assemblies include all revolving doors at exterior of the facility.

Revolving Door, Manual EA B20353001950 Door, Revolving, Manual

Y 1723‐S S 30

B203003 REVOLVING DOORS Assemblies include all revolving doors at exterior of the facility.

Revolving Door, Electric EA B20353002950 Door, Revolving, Electric

Y 1727‐S S 30

B203004 OVERHEAD AND ROLL‐UP DOORS Overhead and roll‐up doors installed in exterior walls or exterior skin. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the assembly level is each door.

Overhead Rollup Door, Manual, up to 24'H x 25'W

SF B20354001950 Door, overhead, manual, up to 24'H x 25'W

Y 1655‐S S 30

B203004 OVERHEAD AND ROLL‐UP DOORS Overhead and roll‐up doors installed in exterior walls or exterior skin. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the assembly level is each door.

Overhead Rollup Door, Electric, up to 24'H x 25'W

SF B20354101950 Door, overhead, roll‐ up, electric, up to 24'H x 25'W

Y 1656‐S S 30

B203004 OVERHEAD AND ROLL‐UP DOORS Overhead and roll‐up doors installed in exterior walls or exterior skin. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the assembly level is each door.

Overhead Rollup Door, Shutter, Electric

SF B20354501950 Shutter, roll‐up, electric Y 1733‐A A 30

B203005 HANGAR DOORS Large aircraft doors used on medium and high bay hangars.

Assemblies would include frames, hardware, hoisting devices, and finish and other associated work.

Hangar Door, Sliding SF B20351102950 Door, sliding Y 1721‐Q 1716‐A

Q/A 40

B203006 BLAST RESISTANT DOORS Special exterior doors used for blast resistance. Assemblies would include frames, hardware, hoisting devices, and finish and other associated work.

Blast Resistant Door, Hurricane Shutters

SF N/A Hurricane Shutters/Blast resistant door

Y 5042‐A A 30

B301001 HIGH SLOPE ROOF COVERINGS Assemblies include roof coverings, such as shingle, wood shake, and standing seam, etc.

Roof, High Sloped SF N/A Roof Y 6440‐A A 30

B301002 LOW SLOPE MEMBRANE SYSTEMS Assemblies include roof coverings, such as built‐up, elastomeric, modified bitumen, etc. Also, walkways or work areas (used to gain access to rooftop equipment) will be included here.

Roof, Low Sloped SF N/A Roof Y 9068‐A A 20

B301099 OTHER ROOFING Roofing not described by the assembly categories listed above.

Roof SF NA Roof Y 9069‐A A 30

C102003 FIRE DOORS Assemblies include all interior fire doors, including all necessary frames, and sensing devices integral with doors. Interior door hardware is located in C102007, Interior Door Hardware.

Fire Door, Swinging LEF C10251101950 Fire Door, swinging Y 1738‐Q Q 30

From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment identification systems Version 1.0

USCG Approved Equipment Enrollment Catalog -

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

C102003 FIRE DOORS Assemblies include all interior fire doors, including all necessary frames, and sensing devices integral with doors. Interior door hardware is located in C102007, Interior Door Hardware.

Fire Door, Sliding LEF C10251102950 Fire Door, sliding Y 1743‐Q Q 30

C102003 FIRE DOORS Assemblies include all interior fire doors, including all necessary frames, and sensing devices integral with doors. Interior door hardware is located in C102007, Interior Door Hardware.

Fire Door, Roll‐up LEF C10251103950 Fire Door, roll‐up Y 1750‐Q 1746‐A

Q/A 30

C102005 INTERIOR OVERHEAD DOORS Overhead doors installed in the interior of a facility. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the assembly level is each door.

Door, overhead, roll‐up, electric, up to 24'H x 25'W

SF B20354101950 Door, overhead, roll‐ up, electric, up to 24'H x 25'W

Y 1656‐S S 30

C102005 INTERIOR OVERHEAD DOORS Overhead doors installed in the interior of a facility. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the assembly level is each door.

Interior Overhead Door, Roll‐up, Manual up to 24'H x 25'W

SF B20354001950 Door, overhead, manual, up to 24'H x 25'W

Y 1655‐S S 30

D101002 PASSENGER ELEVATORS The unit measure at the assembly level is each stop.

Passenger Elevator, Electric, Cable

STP D10151001950 Elevator, cable, electric, passenger

Y 1836‐M 1829‐Q 1792‐A

M/Q/A 40

D101002 PASSENGER ELEVATORS The unit measure at the assembly level is each stop.

Elevator, hydraulic & cable electric passenger ‐certifications

STP N/A Elevator, hydraulic & cable electric passenger ‐ certifications

Y 5433‐A A 40

D101003 FREIGHT ELEVATORS The unit measure at the assembly level is each stop.

Freight Elevator, Electric/Cable STP D10151001950 Elevator, cable, electric, freight

Y 1836‐M 1829‐Q 1792‐A

M/Q/A 40

D101003 FREIGHT ELEVATORS The unit measure at the assembly level is each stop.

Elevator, hydraulic & cable electric freight ‐ certifications

STP N/A Elevator, hydraulic & cable electric freight ‐ certifications

Y 5433‐A A 40

D101004 WHEELCHAIR LIFT Pre‐manufactured lift to gain wheelchair access.

Wheelchair lift STP N/A Wheelchair lift Y 5433‐A A 15

D102001 MOVING STAIRS Moving stairs. Escalator LF D10251001950 Escalator Y 9309‐M M 40 D102002 MOVING WALKS Moving walks. Escalator LF Y NEED TO

DEVELOP

SAM JP

M 40

D102099 OTHER MOVING STAIRS AND WALKS Moving stairs or walks not described by the assembly categories listed above.

General LF N/A Y NEED TO

DEVELOP

SAM JP

D109001 PNEUMATIC TUBE SYSTEMS Pneumatic tube systems. Pneumatic tube system EA D10952001950 Pneumatic tube system Y 1870‐Q Q 40

D109002 CONVEYORS Conveyors. Vertical conveyors EA N/A Vertical conveyors Y 5381‐S S 40 D109007 OVERHEAD CRANES Overhead cranes. Crane, electric bridge, up to 5 ton EA E10951221950 Crane, electric bridge, up to 5 ton Y 1863‐A A 15

D109007 OVERHEAD CRANES Overhead cranes. Crane, electric bridge, 5 to 15 tons

EA E10951222950 Crane, electric bridge, 5 to 15 tons

Y 1865‐Q 1864‐A

Q/A 15

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D109007 OVERHEAD CRANES Overhead cranes. Crane, electric bridge, over 15 tons

EA E10951223950 Crane, electric bridge, over 15 tons

Y 1866‐Q 1867‐A

Q/A 15

D109007 OVERHEAD CRANES Overhead cranes. Crane, manual bridge, up to 5 ton

EA E10951231950 Crane, manual bridge, up to 5 ton

Y 1838‐A A 15

D109007 OVERHEAD CRANES Overhead cranes. Crane, manual bridge, 5 to 15 tons

EA E10951232950 Crane, manual bridge, 5 to 15 tons

Y 1842‐A A 15

D109007 OVERHEAD CRANES Overhead cranes. Crane, manual bridge, over 15 tons

EA E10951233950 Crane, manual bridge, over 15 tons

Y 1843‐A A 15

D109099 OTHER MATERIAL HANDLING SYSTEMS Material or handling systems not described by the assembly categories

Hydraulic Lift (Automotive), General (Shop Post Lifts)

EA E10351001950 Hydraulic Lift, Automotive

Y 1681‐A A 20

D201099 EMERGENCY FIXTURES Emergency fixtures not described by the assembly categories listed above.

Eyewash Station & Shower EA N/A Eyewash Station & Shower

Y 6084‐M M 25

D202002 VALVES AND HYDRANTS Assemblies include all valves and hydrants.

Hose bibbs are included in this assembly. The unit of measure at the assembly level is number of valves and hydrants.

Butterfly Valve, above 4" (& not included in a system)

EA D20251201950 Valve, butterfly, manual, above 4"

Y 1995‐A A 25

D202002 VALVES AND HYDRANTS Assemblies include all valves and hydrants.

Hose bibbs are included in this assembly. The unit of measure at the assembly level is number of valves and hydrants.

Butterfly Valve, above 4" (& not included in a system)

EA D20251202950 Valve, butterfly, auto, above 4"

Y 1996‐A A 25

D202002 VALVES AND HYDRANTS Assemblies include all valves and hydrants.

Hose bibbs are included in this assembly. The unit of measure at the assembly level is number of valves and hydrants.

Check Valve, above 4" (& not included in a system)

EA D20251251950 Valve, check, above 4" Y 1997‐A A 25

D202002 VALVES AND HYDRANTS Assemblies include all valves and hydrants.

Hose bibbs are included in this assembly. The unit of measure at the assembly level is number of valves and hydrants.

Backflow Preventer, up to 4" (& not included in a system)

EA D40151001950 Backflow prevention device, up to 4"

Y 1972‐A A 20

D202002 VALVES AND HYDRANTS Assemblies include all valves and hydrants.

Hose bibbs are included in this assembly. The unit of measure at the assembly level is number of valves and hydrants.

Backflow Preventer, over 4" (& not included in a system)

EA D40151002950 Backflow prevention device, over 4"

Y 1973‐A A 20

D202002 VALVES AND HYDRANTS Assemblies include all valves and hydrants.

Hose bibbs are included in this assembly. The unit of measure at the assembly level is number of valves and hydrants.

Ball Valve, above 4" (& not included in a system)

EA D20251301950 Valve, cock, ball, above 4"

Y 1998‐A A 25

D202002 VALVES AND HYDRANTS Assemblies include all valves and hydrants.

Hose bibbs are included in this assembly. The unit of measure at the assembly level is number of valves and hydrants.

Diaphragm Valve, above 4" (& not included in a system)

EA D20251351950 Valve, diaphragm, above 4"

Y 1999‐A A 25

D202002 VALVES AND HYDRANTS Assemblies include all valves and hydrants.

Hose bibbs are included in this assembly. The unit of measure at the assembly level is number of valves and hydrants.

Gate Valve, above 4" (& not included in a system)

EA D20251401950 Valve, Gate Above 4" Y 2000‐A A 25

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D202002 VALVES AND HYDRANTS Assemblies include all valves and hydrants.

Hose bibbs are included in this assembly. The unit of measure at the assembly level is number of valves and hydrants.

Globe Valve, above 4" (& not included in a system)

EA D20251451950 Valve, globe, manual, above 4"

Y 2001‐A A 25

D202002 VALVES AND HYDRANTS Assemblies include all valves and hydrants.

Hose bibbs are included in this assembly. The unit of measure at the assembly level is number of valves and hydrants.

Globe Valve, above 4" (& not included in a system)

EA D20251452950 Valve, globe, auto, above 4"

Y 2002‐A A 25

D202002 VALVES AND HYDRANTS Assemblies include all valves and hydrants.

Hose bibbs are included in this assembly. The unit of measure at the assembly level is number of valves and hydrants.

Motor Operated Valve, above 4" (& not included in a system)

EA D20251501950 Valve, motor operated, above 4"

Y 2003‐S S 25

D202002 VALVES AND HYDRANTS Assemblies include all valves and hydrants.

Hose bibbs are included in this assembly. The unit of measure at the assembly level is number of valves and hydrants.

OS&Y Valve, above 4" (& not included in a system)

EA D20251551950 Valve, OS&Y (outside stem and yoke) above 4"

Y 2004‐A A 25

D202003 DOMESTIC WATER EQUIPMENT This assembly includes equipment associated with the domestic water supply, including fittings, and specialties required for hookup.

Assemblies include hot water heaters, water treatment plant, that is, water softeners, filters, distillers, etc.;

pumps directly associated with domestic water supply; and tanks for the potable hot or cold water system. The unit of measure at the assembly level is pieces of equipment

Water Heater, Solar ‐closed loop, up to 6 panels

EA D20251901950 Water Heater, Solar ‐ closed loop, up to 6 panels

Y 1696‐S 1702‐ A

S/A 25

D202003 DOMESTIC WATER EQUIPMENT This assembly includes equipment associated with the domestic water supply, including fittings, and specialties required for hookup.

Assemblies include hot water heaters, water treatment plant, that is, water softeners, filters, distillers, etc.;

pumps directly associated with domestic water supply; and tanks for the potable hot or cold water system. The unit of measure at the assembly level is pieces of equipment

Water Heater, Gas, to 120 Gallon EA D20252601950 Water Heater, Gas, to 120 Gallon

Y 1658‐S 1661‐ A

S/A 25

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D202003 DOMESTIC WATER EQUIPMENT This assembly includes equipment associated with the domestic water supply, including fittings, and specialties required for hookup.

Assemblies include hot water heaters, water treatment plant, that is, water softeners, filters, distillers, etc.;

pumps directly associated with domestic water supply; and tanks for the potable hot or cold water system. The unit of measure at the assembly level is pieces of equipment

Water Heater, Oil fired to 100 gals

EA D20252602950 Water Heater, Oil fired to 100 gals

Y 1662‐S 1666‐ A

S/A 25

D202003 DOMESTIC WATER EQUIPMENT This assembly includes equipment associated with the domestic water supply, including fittings, and specialties required for hookup.

Assemblies include hot water heaters, water treatment plant, that is, water softeners, filters, distillers, etc.;

pumps directly associated with domestic water supply; and tanks for the potable hot or cold water system. The unit of measure at the assembly level is pieces of equipment

Water Heater, steam coil, to 2500 gals

EA D20252603950 Water Heater, steam coil, to 2500 gals

Y 1667‐S 1669‐ A

S/A 25

D202003 DOMESTIC WATER EQUIPMENT This assembly includes equipment associated with the domestic water supply, including fittings, and specialties required for hookup.

Assemblies include hot water heaters, water treatment plant, that is, water softeners, filters, distillers, etc.;

pumps directly associated with domestic water supply; and tanks for the potable hot or cold water system. The unit of measure at the assembly level is pieces of equipment

Water Heater, Electric EA D20252603950 Water Heater, Electric Y 6576‐S S 25

D202005 SPECIALTIES Any other special items associated with domestic water supply.

All associated work items, including pipes, fittings, valves, insulation, and hookup should be included in this assembly. The unit of measure at the assembly level is pieces of special equipment

Pressure Relief Valve, above 4" (& not included in a system)

EA D20252621950 Valve, pressure relief, above 4"

Y 2005‐A A 25

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D202005 SPECIALTIES Any other special items associated with domestic water supply.

All associated work items, including pipes, fittings, valves, insulation, and hookup should be included in this assembly. The unit of measure at the assembly level is pieces of special equipment

Pressure Regulator Valve > 4" (& not included in a system)

EA D20252651950 Valve, pressure regulator, above 4"

Y 2006‐A A 25

D202005 SPECIALTIES Any other special items associated with domestic water supply.

All associated work items, including pipes, fittings, valves, insulation, and hookup should be included in this assembly. The unit of measure at the assembly level is pieces of special equipment

Sediment Strainer Valve > 4" (& not included in a system)

EA D20252701950 Valve, sediment strainer, above 4"

Y 2007‐A A 25

D202005 SPECIALTIES Any other special items associated with domestic water supply.

All associated work items, including pipes, fittings, valves, insulation, and hookup should be included in this assembly. The unit of measure at the assembly level is pieces of special equipment

Automatic Valve, above 4" (& not included in a system)

EA D20253101950 Valve, auto, above 4" Y 1993‐A A 25

D202005 SPECIALTIES Any other special items associated with domestic water supply.

All associated work items, including pipes, fittings, valves, insulation, and hookup should be included in this assembly. The unit of measure at the assembly level is pieces of special equipment

Auto Diaphragm Valve, above 4" (& not included in a system)

EA D20253102950 Valve, auto diaphragm, above 4"

Y 1994‐A A 25

D209004 POOL PIPING AND EQUIPMENT Assemblies include pumps and associated equipment with pools, including specialties required for hook‐up.

The unit of measure at the assembly level is each.

Swimming Pool GPM F10451101950 Swimming Pool Y 1862‐M M 25

D209005 COMPRESSED AIR SYSTEM (NON‐

BREATHING)

Compressed air system (non‐breathing). Air Compressor PSI D30951101950 Air compressor, gas engine powered

Y 1737‐M 1731‐S

M/S 25

D209005 COMPRESSED AIR SYSTEM (NON‐

BREATHING)

Compressed air system (non‐breathing). Air Compressor PSI D30951141950 Air compressor, Centrifugal, to 40 HP

Y 1740‐Q Q 25

D209005 COMPRESSED AIR SYSTEM (NON‐

BREATHING)

Compressed air system (non‐breathing). Air Compressor PSI D30951142950 Air compressor, Centrifugal, over 40 HP

Y 1754‐M 1751‐S 1744‐ A

M/S/A 25

D209005 COMPRESSED AIR SYSTEM (NON‐

BREATHING)

Compressed air system (non‐breathing). Air Compressor PSI D30951181950 Air compressor, reciprocating, < 5 HP

Y 1756‐Q Q 25

D209005 COMPRESSED AIR SYSTEM (NON‐

BREATHING)

Compressed air system (non‐breathing). Air Compressor PSI D30951182950 Air compressor, reciprocating, 5 to 40

HP

Y 1761‐Q Q 25

D209005 COMPRESSED AIR SYSTEM (NON‐

BREATHING)

Compressed air system (non‐breathing). Air Compressor PSI D30951183950 Air compressor, reciprocating, > 40 HP

Y 1766‐Q Q 25

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D209005 COMPRESSED AIR SYSTEM (NON‐

BREATHING)

Compressed air system (non‐breathing). Air Dryer PSI Y NEED TO

DEVELOP

SAM JP

D209099 OTHER SPECIAL PLUMBING SYSTEMS This system includes special plumbing systems not described by the assembly categories listed above, such as fountain piping systems and devices.

Duplex Sump EA D20959051950 Pump, duplex submersible

Y 1677‐S S 25

D209099 OTHER SPECIAL PLUMBING SYSTEMS This system includes special plumbing systems not described by the assembly categories listed above, such as fountain piping systems and devices.

Submersible Pump EA D20959101950 Pump, submersible, 1 H.P. and over

Y 1691‐S S 25

D209099 OTHER SPECIAL PLUMBING SYSTEMS This system includes special plumbing systems not described by the assembly categories listed above, such as fountain piping systems and devices.

Pump, Centrifugal, over 1 hp EA D30454101950 Pump, Centrifugal, over 1 hp

Y 1671‐S S 25

D209099 OTHER SPECIAL PLUMBING SYSTEMS This system includes special plumbing systems not described by the assembly categories listed above, such as fountain piping systems and devices.

Pump, Centrifugal, w/ reduction gear, over 1 hp

EA D30454102950 Pump, Centrifugal, w/ reduction gear, over 1 hp

Y 1674‐S S 25

D209099 OTHER SPECIAL PLUMBING SYSTEMS This system includes special plumbing systems not described by the assembly categories listed above, such as fountain piping systems and devices.

Oxygen Monitor EA D20959301950 Oxygen Monitor Y 9314‐A 9315‐ Q

Q/S 25

D301099 OTHER ENERGY SUPPLY Energy supply not described by the assembly categories listed above.

General MBH Y NEED TO

DEVELOP

SAM JP

D302001 STEAM BOILERS Assemblies include boilers, expansion tanks, chemical feeders, air separators, pumps, heat exchangers, boiler feed units, etc.

This assembly would also include fittings and specialties and the flue stack. The unit of measure at the assembly level is each system

Oil/Gas/Comb., Steam ‐ 500 to

1000 MBH

MBH D30251403950 Boiler, steam , Oil/Gas/Comb., 500 to

1000 MBH

Y 1927‐M 1926‐Q 1925‐A

M/Q/A 30

D302001 STEAM BOILERS Assemblies include boilers, expansion tanks, chemical feeders, air separators, pumps, heat exchangers, boiler feed units, etc.

This assembly would also include fittings and specialties and the flue stack. The unit of measure at the assembly level is each system

Oil/Gas/Comb., Steam ‐ 120 to

500 MBH

MBH D30251402950 Boiler, steam , Oil/Gas/Comb., 120 to

500 MBH

Y 1924‐M 1923‐Q 1922‐A

M/Q/A 30

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D302001 STEAM BOILERS Assemblies include boilers, expansion tanks, chemical feeders, air separators, pumps, heat exchangers, boiler feed units, etc.

This assembly would also include fittings and specialties and the flue stack. The unit of measure at the assembly level is each system

Oil/Gas/Comb., Steam ‐ up to

120 MBH

MBH D30251401950 Boiler, steam , Oil/Gas/Comb., up to

120 MBH

Y 1921‐M 1920‐Q 1919‐A

M/Q/A 30

D302001 STEAM BOILERS Assemblies include boilers, expansion tanks, chemical feeders, air separators, pumps, heat exchangers, boiler feed units, etc.

This assembly would also include fittings and specialties and the flue stack. The unit of measure at the assembly level is each system

Oil/Gas/Comb., Steam ‐ over

1000 MBH

MBH D30251404950 Boiler, steam , Oil/Gas/Comb., over

1000 MBH

Y 1930‐M 1929‐Q 1928‐A

M/Q/A 30

D302001 STEAM BOILERS Assemblies include boilers, expansion tanks, chemical feeders, air separators, pumps, heat exchangers, boiler feed units, etc.

This assembly would also include fittings and specialties and the flue stack. The unit of measure at the assembly level is each system

Electric, Steam MBH D30251101950 Boiler, electric, to 1500 gal.

Y 1905‐Q Q 30

D302002 HOT WATER BOILERS Assemblies include boilers, expansion tanks, chemical feeders, air separators, pumps, heat exchangers, boiler feed units, etc.

This assembly would also include fittings and specialties and the flue stack. The unit of measure at the assembly level is each system

Electric, Hot Water MBH D30251101950 Boiler, electric, to 1500 gal.

Y 1905‐Q Q 30

D302002 HOT WATER BOILERS Assemblies include boilers, expansion tanks, chemical feeders, air separators, pumps, heat exchangers, boiler feed units, etc.

This assembly would also include fittings and specialties and the flue stack. The unit of measure at the assembly level is each system

Oil/Gas/Comb., Hot Water ‐ up to 120 MBH

MBH D30251301950 Boiler, Hot Water; oil, gas, or combination fired, up to 120 MBH

Y 1908‐M 1907‐Q 1906‐A

M/Q/A 30

D302002 HOT WATER BOILERS Assemblies include boilers, expansion tanks, chemical feeders, air separators, pumps, heat exchangers, boiler feed units, etc.

This assembly would also include fittings and specialties and the flue stack. The unit of measure at the assembly level is each system

Oil/Gas/Comb., Hot Water ‐ 120 to 500 MBH

MBH D30251302950 Boiler, Hot Water; oil, gas, or combination fired, 120 to 500 MBH

Y 1911 ‐ M 1910 ‐ Q 1909 ‐ A

M/Q/A 30

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D302002 HOT WATER BOILERS Assemblies include boilers, expansion tanks, chemical feeders, air separators, pumps, heat exchangers, boiler feed units, etc.

This assembly would also include fittings and specialties and the flue stack. The unit of measure at the assembly level is each system

Oil/Gas/Comb., Hot Water ‐ 500 to 1000 MBH

MBH D30251303950 Boiler, Hot Water; oil, gas, or combination fired, 500 to 1000 MBH

Y 1914 ‐ M 1913 ‐ Q 1912 ‐ A

M/Q/A 30

D302002 HOT WATER BOILERS Assemblies include boilers, expansion tanks, chemical feeders, air separators, pumps, heat exchangers, boiler feed units, etc.

This assembly would also include fittings and specialties and the flue stack. The unit of measure at the assembly level is each system

Oil/Gas/Comb. over 1000 MBH MBH D30251304950 Boiler, Hot Water; oil, gas, or combination fired, over 1000 MBH

Y 1918 ‐ M 1917 ‐ Q 1916 ‐ A

M/Q/A 30

D302003 FURNACES This is a system that heats air. Assemblies would include furnace and necessary fittings and specialties required for hookup, including flue and stack. The unit of measure at the assembly level is each.

General MBH D30551102950 Unit heater, gas infrared

Y 1944‐A A 25

D302003 FURNACES This is a system that heats air. Assemblies would include furnace and necessary fittings and specialties required for hookup, including flue and stack. The unit of measure at the assembly level is each.

General MBH D30551103950 Space Heater, unit heater, steam

Y 2077‐A A 25

D302003 FURNACES This is a system that heats air. Assemblies would include furnace and necessary fittings and specialties required for hookup, including flue and stack. The unit of measure at the assembly level is each.

General MBH D30551101950 Unit heater, gas radiant Y 1943‐A A 25

D302003 FURNACES This is a system that heats air. Assemblies would include furnace and necessary fittings and specialties required for hookup, including flue and stack. The unit of measure at the assembly level is each.

General MBH D30551221950 Forced Air Heater, Unit Heater, oil or gas fired up to 120 MBH

Y 1935‐Q 1934‐A

Q/A 25

D302003 FURNACES This is a system that heats air. Assemblies would include furnace and necessary fittings and specialties required for hookup, including flue and stack. The unit of measure at the assembly level is each.

General MBH D30551222950 Forced Air Heater, Unit Heater, oil or gas fired over 120 MBH

Y 1937‐Q 1936‐A

Q/A 25

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D302003 FURNACES This is a system that heats air. Assemblies would include furnace and necessary fittings and specialties required for hookup, including flue and stack. The unit of measure at the assembly level is each.

General MBH Unit Heater, Electric Y 8486‐A A 25

D302004 FUEL‐FIRED UNIT HEATERS Assemblies would include unit heaters and the energy supply system hookup (other than electrical), including all necessary pipe, fittings, and specialties required for hook‐up. Flue and stack, if required, are included in this assembly. The unit of measure at the assembly level is each

General MBH D30551102950 Unit heater, gas infrared

Y 1944‐A A 25

D302004 FUEL‐FIRED UNIT HEATERS Assemblies would include unit heaters and the energy supply system hookup (other than electrical), including all necessary pipe, fittings, and specialties required for hook‐up. Flue and stack, if required, are included in this assembly. The unit of measure at the assembly level is each

General MBH D30551103950 Space Heater, unit heater, steam

Y 2077‐A A 25

D302004 FUEL‐FIRED UNIT HEATERS Assemblies would include unit heaters and the energy supply system hookup (other than electrical), including all necessary pipe, fittings, and specialties required for hook‐up. Flue and stack, if required, are included in this assembly. The unit of measure at the assembly level is each

General MBH D30551101950 Unit heater, gas radiant Y 1943‐A A 25

D302004 FUEL‐FIRED UNIT HEATERS Assemblies would include unit heaters and the energy supply system hookup (other than electrical), including all necessary pipe, fittings, and specialties required for hook‐up. Flue and stack, if required, are included in this assembly. The unit of measure at the assembly level is each

General MBH D30551221950 Forced Air Heater, Unit Heater, oil or gas fired up to 120 MBH

Y 1935‐Q 1934‐A

Q/A 25

D302004 FUEL‐FIRED UNIT HEATERS Assemblies would include unit heaters and the energy supply system hookup (other than electrical), including all necessary pipe, fittings, and specialties required for hook‐up. Flue and stack, if required, are included in this assembly. The unit of measure at the assembly level is each

General MBH D30551222950 Forced Air Heater, Unit Heater, oil or gas fired over 120 MBH

Y 1937‐Q 1936‐A

Q/A 25

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D302004 FUEL‐FIRED UNIT HEATERS Assemblies would include unit heaters and the energy supply system hookup (other than electrical), including all necessary pipe, fittings, and specialties required for hook‐up. Flue and stack, if required, are included in this assembly. The unit of measure at the assembly level is each

General MBH Unit Heater, Electric Y 8486‐A A 25

D302005 AUXILIARY EQUIPMENT Assemblies would include any other equipment associated with heat generating systems. The unit of measure at the assembly level is each.

Boiler Feed water Tank MBH D30253101950 Pump, boiler fuel oil Y 1931‐S S 30

D302005 AUXILIARY EQUIPMENT Assemblies would include any other equipment associated with heat generating systems. The unit of measure at the assembly level is each.

Expansion/Compression/Deaerat or Tank

MBH D30252101950 Expansion/Compressio n/Deaerator Tank

Y 1931‐S S 30

D302005 AUXILIARY EQUIPMENT

Assemblies would include any other equipment associated with heat generating systems. The unit of measure at the assembly level is each. Pump, boiler fuel oil MBH D30253101950 Pump, boiler fuel oil Y 1939‐S S 30

D302005 AUXILIARY EQUIPMENT

Assemblies would include any other equipment associated with heat generating systems. The unit of measure at the assembly level is each. Pump, condensate return, over 1 MBH D30253102950 Pump, condensate retur Y 1940‐S S 25

D302005 AUXILIARY EQUIPMENT

Assemblies would include any other equipment associated with heat generating systems. The unit of measure at the assembly level is each. Pump, steam condensate return, MBH D30253103950 Pump, steam condensat Y 1941‐S S 25

D302005 AUXILIARY EQUIPMENT

Assemblies would include any other equipment associated with heat generating systems. The unit of measure at the assembly level is each. Pump, Centrifugal, over 1 hp EA D30454101950 Pump, Centrifugal, over Y 1671‐S S 25

D302099 OTHER HEAT GENERATING SYSTEMS Heat generating systems not described in the assembly categories listed

General MBH Y NEED TO

DEVELOP

SAM JP

D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook‐up. The unit of measure at the assembly level is each.

Chiller, Reciprocating TON D30351302950 Chiller, reciprocating, air cooled, over 25 Tons

Y 2054‐M 2053‐A

M/A 20

D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook‐up. The unit of measure at the assembly level is each.

Chiller, Centrifugal TON D30351401950 Chiller, centrifugal water cooled, up to 100 Tons

Y 1802‐W 1801‐M 1804‐S 1798‐A

W/M/S/A 20

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook‐up. The unit of measure at the assembly level is each.

Cooling Tower TON D30351101950 Cooling tower, water, forced draft, up to 50 tons

Y 1739‐S S 20

D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook‐up. The unit of measure at the assembly level is each.

Cooling Tower TON D30351102950 Cooling tower, water, forced draft, 50 thru 500 tons

Y 1757‐S S 20

D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook‐up. The unit of measure at the assembly level is each.

Cooling Tower TON D30351103950 Cooling tower, water, forced draft, 500 to 1000 tons

Y 1763‐S S 20

D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook‐up. The unit of measure at the assembly level is each.

Chiller, Screw TON D30351602950 Chiller, screw, water cooled, over 100 tons

Y 1819‐M 1817‐S 1815‐ A

M/S/A 20

D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook‐up. The unit of measure at the assembly level is each.

Chiller, Reciprocating TON D30351301950 Chiller, reciprocating, air cooled, up to 25 Tons

Y 2048‐M 2046‐A

M/A 20

D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook‐up. The unit of measure at the assembly level is each.

Chiller, Absorption TON D30351502950 Chiller, absorption unit, 500 to 5000 tons

Y 1797‐Q 1796‐A

Q/A 20

D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook‐up. The unit of measure at the assembly level is each.

Chiller, Reciprocating TON D30351351950 Chiller, reciprocating, water cooled, up to 50 Tons

Y 1808‐M 1806‐A

M/A 20

D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook‐up. The unit of measure at the assembly level is each.

Chiller, Reciprocating TON D30351352950 Chiller, reciprocating, water cooled, over 50 Tons

Y 1811‐M 1809‐A

M/A 20

D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook‐up. The unit of measure at the assembly level is each.

Chiller, Centrifugal TON D30351402950 Chiller, centrifugal water cooled, over 100 Tons

Y 2034‐W 2032‐Q 2031‐S 2030‐ A

W/Q/S/A 20

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook‐up. The unit of measure at the assembly level is each.

Chiller, Absorption TON D30351501950 Chiller, absorption unit, up to 500 tons

Y 1793‐Q 1791‐A

Q/A 20

D303001 CHILLED WATER SYSTEMS Assemblies include condensers, compressors, chillers, pumps, cooling towers, etc., including fittings and specialties required for hook‐up. The unit of measure at the assembly level is each.

Chiller, Screw TON D30351601950 Chiller, screw, water cooled, up to 100 tons

Y 1814‐M 1813‐S 1812‐ A

M/S/A 20

D303002 DIRECT EXPANSION SYSTEMS Assemblies include condensers, compressors, heat pumps, and refrigerant piping. The unit of measure at the assembly level is each.

Evaporative Cooler TON D30351801950 Evaporative cooler, rotating drum

Y 1818‐A A 15

D303002 DIRECT EXPANSION SYSTEMS Assemblies include condensers, compressors, heat pumps, and refrigerant piping. The unit of measure at the assembly level is each.

Condenser, Air Cooled TON D30352203950 Condensing unit, air cooled, over 100 tons

Y 4511‐Q 1698‐A

Q/A 15

D303002 DIRECT EXPANSION SYSTEMS Assemblies include condensers, compressors, heat pumps, and refrigerant piping. The unit of measure at the assembly level is each.

Condenser, Water Cooled TON D30352402950 Condensing unit, water cooled, 26 tons to 100 tons

Y 1708‐Q 1703‐A

Q/A 15

D303002 DIRECT EXPANSION SYSTEMS Assemblies include condensers, compressors, heat pumps, and refrigerant piping. The unit of measure at the assembly level is each.

Condenser, Water Cooled TON D30352403950 Condensing unit, water cooled, over 100 tons

Y 1724‐Q 1718‐A

Q/A 15

D303002 DIRECT EXPANSION SYSTEMS Assemblies include condensers, compressors, heat pumps, and refrigerant piping. The unit of measure at the assembly level is each.

Condenser, Air Cooled TON D30352101950 Condenser, air cooled, 3 Tons to 25 Tons

Y 1779‐Q 1776‐A

Q/A 15

D303002 DIRECT EXPANSION SYSTEMS Assemblies include condensers, compressors, heat pumps, and refrigerant piping. The unit of measure at the assembly level is each.

Condenser, Water Cooled TON D30352401950 Condensing unit, water cooled, 3 tons to 25 tons

Y 1713‐Q 1710‐A

Q/A 15

D303002 DIRECT EXPANSION SYSTEMS Assemblies include condensers, compressors, heat pumps, and refrigerant piping. The unit of measure at the assembly level is each.

Condenser, Air Cooled TON D30352202950 Condensing unit, air cooled, 26 tons to 100 tons

Y 1831‐Q 1828‐A

Q/A 15

D303002 DIRECT EXPANSION SYSTEMS Assemblies include condensers, compressors, heat pumps, and refrigerant piping. The unit of measure at the assembly level is each.

Condenser, Air Cooled TON D30352201950 Condensing unit, air cooled, 3 tons to 25 tons

Y 1826‐Q 1825‐A

Q/A 15

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D303002 DIRECT EXPANSION SYSTEMS Assemblies include condensers, compressors, heat pumps, and refrigerant piping. The unit of measure at the assembly level is each.

Condenser, Air Cooled TON D30352103950 Condenser, air cooled, over 100 tons

Y 1694‐Q 1820‐A

Q/A 15

D303002 DIRECT EXPANSION SYSTEMS Assemblies include condensers, compressors, heat pumps, and refrigerant piping. The unit of measure at the assembly level is each.

Evaporative Cooler TON D30351701950 Evaporative cooler Y 1810‐A A 15

D303002 DIRECT EXPANSION SYSTEMS Assemblies include condensers, compressors, heat pumps, and refrigerant piping. The unit of measure at the assembly level is each.

Condenser, Air Cooled TON D30352102950 Condenser, air cooled, 26 tons to 100 tons

Y 9065‐Q 9064‐A

Q/A 15

D303099 OTHER COOLING GENERATING SYSTEMS Cooling generating systems not described by the assembly categories

Compressor, DX Refrigeration TON D30352601950 Compressor, DX refrigeration, to 25 tons

Y 1772‐Q Q 15

D303099 OTHER COOLING GENERATING SYSTEMS Cooling generating systems not described by the assembly categories

Compressor, DX Refrigeration TON D30352602950 Compressor, DX refrigeration, to 25 to 100 tons

Y 1774‐Q Q 15

D303099 OTHER COOLING GENERATING SYSTEMS Cooling generating systems not described by the assembly categories

Fluid cooler, 2 fans (no compressor)

TON D30352901950 Fluid cooler, 2 fans (no compressor)

Y 1758‐A A 15

D303099 OTHER COOLING GENERATING SYSTEMS Pump, Centrifugal, over 1 hp EA D30454101950 Pump, Centrifugal, over Y 1671‐S S 25

D304001 AIR DISTRIBUTION, HEATING AND

COOLING

Assemblies include heating coils, cooling coils, and fittings and specialties required for water hook‐up. This assembly also includes duct heaters, filters, humidifiers, supply and return ductwork, dampers, fire dampers, supply and return grilles, registers and diffusers, turning vanes, sound traps, and all associated insulation. The unit of measure at the assembly level is CF/M

Air Filters, Electrostatic CF/M D30451501950 Air Filters, Electrostatic Y 9316‐Q Q 15

D304001 AIR DISTRIBUTION, HEATING AND

COOLING

Assemblies include heating coils, cooling coils, and fittings and specialties required for water hook‐up. This assembly also includes duct heaters, filters, humidifiers, supply and return ductwork, dampers, fire dampers, supply and return grilles, registers and diffusers, turning vanes, sound traps, and all associated insulation. The unit of measure at the assembly level is CF/M

Variable Air Volume Box CF/M D30451601950 Variable Air Volume Box

Y 1788‐S S 15

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D304001 AIR DISTRIBUTION, HEATING AND

COOLING

Assemblies include heating coils, cooling coils, and fittings and specialties required for water hook‐up. This assembly also includes duct heaters, filters, humidifiers, supply and return ductwork, dampers, fire dampers, supply and return grilles, registers and diffusers, turning vanes, sound traps, and all associated insulation. The unit of measure at the assembly level is CF/M

Fire Dampers CF/M D30451701950 Fire damper Y 1787‐A A 15

D304007 EXHAUST SYSTEMS Assemblies include ductwork grilles, registers, diffusers, fans, and all associated work. The unit of measure at the assembly level is each system.

Fan System, Roof Exhaust CF/M D30452202950 Fan, centrifugal, 5,000 to 10,000 CFM

Y 1852‐S S 15

D304007 EXHAUST SYSTEMS Assemblies include ductwork grilles, registers, diffusers, fans, and all associated work. The unit of measure at the assembly level is each system.

Fan System, Roof Exhaust CF/M D30452203950 Fan, centrifugal, over

10,000 CFM

Y 9066‐S S 15

D304007 EXHAUST SYSTEMS Assemblies include ductwork grilles, registers, diffusers, fans, and all associated work. The unit of measure at the assembly level is each system.

Fan System, Roof Exhaust CF/M D30452101950 Fan, axial, up to 5,000

CFM

Y 1837‐S S 15

D304007 EXHAUST SYSTEMS Assemblies include ductwork grilles, registers, diffusers, fans, and all associated work. The unit of measure at the assembly level is each system.

Fan System, Roof Exhaust CF/M D30452103950 Fan, axial, 36" to 48" dia (over 10,000 CFM)

CFM

Y 1824‐S S 15

D304007 EXHAUST SYSTEMS Assemblies include ductwork grilles, registers, diffusers, fans, and all associated work. The unit of measure at the assembly level is each system.

Fan System, Roof Exhaust CF/M D30452201950 Fan, centrifugal, up to

5,000 CFM

Y 1841‐S S 15

D304007 EXHAUST SYSTEMS Assemblies include ductwork grilles, registers, diffusers, fans, and all associated work. The unit of measure at the assembly level is each system.

Fan System, Roof Exhaust ‐ 5,000

‐ 10,000 CFM

CF/M D30452102950 Fan, axial, 5,000 to

10,000 CFM

Y 1832‐S S 15

D304007 EXHAUST SYSTEMS Assemblies include ductwork grilles, registers, diffusers, fans, and all associated work. The unit of measure at the assembly level is each system.

Fume Hood Exhaust System CF/M D30452501950 Hood and Blower Y 1771‐Q 1767‐A

Q/A 15

D304007 EXHAUST SYSTEMS Assemblies include ductwork grilles, registers, diffusers, fans, and all associated work. The unit of measure at the assembly level is each system.

Fan System, Wall Exhaust, Axial CF/M D30452101950 Fan, axial, up to 5,000

CFM

Y 1837‐S S 15

*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment

Uniformat II Level 4

Material/Equipment Category Level 4 Definition Component Type UOM RS Means/ Reference Number

RS Means/Reference Description

PM Existing SAM Job Plan Numbers

Frequency Design Life From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database

D304007 EXHAUST SYSTEMS Assemblies include ductwork grilles, registers, diffusers, fans, and all associated work. The unit of measure at the assembly level is each system.

Fan System, Wall Exhaust, Centrifugal

CF/M D30452201950 Fan, centrifugal, up to

5,000 CFM

Y 1841‐S S 15

D304008 AIR HANDLING UNITS Air handling units. Air Handling Unit CF/M D30451101950 Air Handling Unit, 3 thru 24 Tons

Y 1780‐Q 1778‐A

Q/A 20

D304008 AIR HANDLING UNITS Air handling units. Air Handling Unit CF/M D30451102950 Air Handling Unit, 25 Thru 50 Tons

Y 1783‐Q 1782‐A

Q/A 20

D304008 AIR HANDLING UNITS Air handling units. Air Handling Unit CF/M D30451103950 Air Handling Unit, over 50 Tons

Y 1786‐Q 1785‐A

Q/A 20

D304008 AIR HANDLING UNITS Air handling units. Air Handling Unit ‐ Computer RM CF/M D30451121950 Air Handling Unit, computer room

Y 1790‐Q 1789‐A

Q/A 20

D304099 OTHER DISTRIBUTION SYSTEMS Distribution systems not described by the assembly categories listed above.

Heat exchanger, steam MBH D30456001950 Heat exchanger, steam Y 1938‐S S 15

D305002 UNIT HEATERS Assemblies include the complete terminal unit and wall sleeve with all controls.

Gas Infrared EA D30551102950 Unit heater, gas infrared

Y 1944‐A A 25

D305002 UNIT HEATERS Assemblies include the complete terminal unit and wall sleeve with all controls.

Steam EA D30551103950 Space Heater, unit heater, steam

Y 2077‐A A 25

D305002 UNIT HEATERS Assemblies include the complete terminal unit and wall sleeve with all controls.

Gas Radiant EA D30551101950 Unit heater, gas radiant Y 1943‐A A 25

D305002 UNIT HEATERS Assemblies include the complete terminal unit and wall sleeve with all controls.

Gas Radiant EA D30551221950 Forced Air Heater, Unit Heater, oil or gas fired up to 120 MBH

Y 1935‐Q 1934‐A

Q/A 25

D305002 UNIT HEATERS Assemblies include the complete terminal unit and wall sleeve with all controls.

Gas Radiant EA D30551222950 Forced Air Heater, Unit Heater, oil or gas fired over 120 MBH

Y 1937‐Q 1936‐A

Q/A 25

D305002 UNIT HEATERS Assemblies include the complete terminal unit and wall sleeve with all controls.

Gas Radiant EA Unit Heater, Electric Y 8486‐A A 25

D305003 FAN COIL UNITS Assemblies include the complete terminal unit and wall sleeve with all controls.

Fan Coil Unit EA D30451201950 Fan Coil Unit Y 1855‐Q, 1854‐S

Q/S 15

D305004 FIN TUBE RADIATION Assemblies include the complete terminal unit and wall sleeve with all controls.

Fin Tube Radiation, Electric EA Fin Tube Radiation Y 8486‐A A 30

D305004 FIN TUBE RADIATION Assemblies include the complete terminal unit and wall sleeve with all controls.

Fin Tube Radiation, Hot Water EA D30551103950 Unit heater, steam/hot water

Y 2077‐A A 30

D305005 ELECTRIC HEATING Assemblies include the complete terminal unit and wall sleeve with all controls.

Electric Heating EA Electric Heating Y…