This document contains specifications for a federal construction contract requiring chemical termite control services. The contractor must provide all required personnel, materials, equipment, tools and supervision to treat structures for subterranean termites in accordance with the specifications. The services include applying liquid termiticides to soil barriers and structures using rodding, trenching and other methods. The contractor must be licensed for structural pest control and certified in termiticide application. The specifications provide detailed requirements for mixing and applying termiticides, disposal, recordkeeping, inspections, protection of treated areas, and a five-year warranty against reinfestation. The related solicitation is for building and site repairs at a US Coast Guard facility in North Carolina with a magnitude between $5-10 million. The solicitation is limited to eligible 8(a) small businesses and requires attendance at a mandatory site visit, with questions due by 23 March 2022 and bids due on an unspecified later date.

View the file

Other files

File Type Posted
21PAC131 Abstract of Offers Construction.pdf PDF
J13 Section 05 51 00 Metal Stairs.pdf PDF
J12 Section 31 31 16.19 termite Control Barriers.pdf PDF
J10 Site Visit Sign In Sheet March 22 2022.pdf PDF
J15 C8601 D Pre alteration Hazardous Materials Survey Report REV.pdf PDF
Amend 3 Q A 21PAC131 pg 2 to 10.pdf PDF
J9 Site Visit Sign In Sheet March 15 2022.pdf PDF
J14 Section 05 52 00 Metal Railings.pdf PDF
Amend Three 21PAC131 SF30-16.pdf PDF
Amend Two 21PAC131 SF30-16 032822.pdf PDF
Amend One 21PAC131 SF30-16.pdf PDF
Amend One pg 2 to 4 031622.pdf PDF
J2 Specifications PN 11731512.pdf PDF
J7 CEUC EQUIPMENT ENROLLMENT FORM.xlsx XLSX spreadsheet
J4 C7003 - Reference DWG 6.pdf PDF
J7 CEUC USCG APPROVED EQUIPMENT ENROLLMENT CATALOG.pdf PDF
J3 C8601-D Sheets 16-30 of 134.pdf PDF
J3 C8601-D Sheets 31-45 of 134.pdf PDF
J4 C8540 - Reference DWG 10.pdf PDF
J3 C8601-D Sheets 76-90 of 134.pdf PDF
J1 SF1442 21PAC131 022822.pdf PDF
J5 WD NC20220069 02252022.PDF PDF
J4 C7219 - Reference DWG 7.pdf PDF
J3 C8601-D Sheets 121-134 of 134.pdf PDF
J3 C8601-D Sheets 91-105 of 134.pdf PDF
J8 Contractor_Responsibility_Questionair_-_New.rtf RTF text file
J4 C8316 - Reference DWG 9.pdf PDF
J1 21PAC131 IFB pages 3 to 53.pdf PDF
J4 C8600-D - Reference DWG 11.pdf PDF
J3 C8601-D Sheet 106 of 134.pdf PDF
J3 C8601-D Sheets 107-120 of 134.pdf PDF
J3 C8601-D Sheets 1-15 of 134.pdf PDF
J4 C3840 - Reference DWG 2.pdf PDF
J4 C6646 - Reference DWG 3.pdf PDF
J3 C8601-D Sheets 46-60 of 134.pdf PDF
J4 C050385 - Reference 1.pdf PDF
J4 C7943 DWG SET Reference DWG 8.pdf PDF
J5 WD NC20220062 02252022.PDF PDF
J4 C6875 - Reference DWG 5.pdf PDF
J7 C8601-D CZMA Consistency Letter.pdf PDF
J3 C8601-D sheets 61-75 of 134.pdf PDF
J6 RFI 21PAC131.docx DOCX document
J4 C6827 - Reference DWG 4.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P/N 11731512

SECTION 31 31 16.13

CHEMICAL TERMITE CONTROL

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced.

The publications are referred to within the text by the basic designation only.

U.S. DEPARTMENT OF DEFENSE (DOD)

DODI 4150.07 (2019) DOD Pest Management Program

1.2 ADMINISTRATIVE REQUIREMENTS

Coordinate work related to final grades, landscape plantings, foundations, or any other alterations to finished construction which might alter the condition of treated soils with this specification.

1.3 SUBMITTALS

The Contractor shall submit the following in accordance with Section 01 33 00, “SUBMITTAL PROCEDURES”. Note that approval of the submittals by the Designer or Contracting Officer’s Representative (COR) shall not be construed as relieving the

Contractor from responsibility for compliance with the specifications nor from responsibility of errors of any sort in the submittals.

A. Preconstruction Submittals

1. Termiticide Application Plan; G

B. Product Data

1. Termiticides

C. Design Data

1. Mixing Formulation

D. Test Reports

1. Soil Moisture

2. Calibration Test

E. Certificates

1. Qualifications; G

2. Foundation Exterior

3. Utilities and Vents

4. Crawl and Plenum Air Spaces

5. List of Equipment

F. Manufacturer's Instructions

1. Termiticides

G. Closeout Submittals

1. Verification of Measurement

2. Warranty

3. Pest Management Report

1.4 QUALITY CONTROL

A. Regulatory Requirements

Comply with DODI 4150.07 for requirements on Contractor's licensing, certification, and record keeping. Maintain daily records using the Pest Management Maintenance

Record, DD Form 1532-1, or a computer generated equivalent, and submit copies of records when requested by the Contracting Officer’s Representative (COR). These forms may be obtained from the main web site:

http://www.dtic.mil/whs/directives/forms/eforms/dd1532-1.pdf

B. Qualifications

For the application of pesticides, use the services of an applicator whose principal business is pest control. The applicator must be commercially certified in the state where the work is to be performed as required by DODI 4150.07. Termiticide applicators must also be certified in the U.S. Environmental Protection Agency (EPA) pesticide applicator category which includes structural pest control. Submit a copy of the pest control business license and pesticide applicator certificates.

http://www.dtic.mil/whs/directives/forms/eforms/dd1532-1.pdf

C. Safety Requirements

Formulate, treat, and dispose of termiticides and their containers in accordance with label directions. Draw water for formulating only from sites designated by the

Contracting Officer, and fit the filling hose with a backflow preventer meeting local plumbing codes or standards. Perform filling operations under the direct and continuous observation of a contractor's representative to prevent overflow. Secure pesticides and related materials under lock and key when unattended. Ensure that proper protective clothing and equipment are worn and used during all phases of termiticide application. Dispose of used pesticide containers off Government property.

1.5 DELIVERY, STORAGE, AND HANDLING

A. Delivery

Deliver termiticide material to the site in the original unopened containers bearing legible labels indicating the EPA registration number, manufacturer's registered uses and in new or otherwise good condition as supplied by the manufacturer or formulator.

B. Inspection

Inspect termiticides upon arrival at the job site for conformity to type and quality in accordance with paragraph TERMITICIDES. Each label must bear evidence of registration under the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA), as amended or under appropriate regulations of the host county. Inspect other materials for conformance with specified requirements. Remove unacceptable materials from the job site.

C. Storage

Storage of pesticides on the installation will not be permitted unless it is written into the contract.

D. Handling

Handle and mix termiticides in accordance with the manufacturer's label and SDS, preventing contamination by dirt, water, and organic material. Protect termiticides from weather elements as recommended by the manufacturer's label and SDS. Spill kits must be maintained on pest control vehicles and must be available at the mixing site. Conduct termiticide mixing in an area with adequate spill containment.

1.6 SITE CONDITIONS

The following site conditions determine the acceptable time of application.

A. Soil Moisture

Test soils to be treated immediately before application. Test soil moisture content to a minimum depth of 3 inches. The soil moisture must be as recommended by the termiticide manufacturer. Application of thetermiticide is not permitted when soil moisture content exceeds manufacturer's recommendations.

B. Runoff and Wind Drift

Application of termiticide will not be permitted during or immediately following heavy rains, when conditions may allow runoff, or create an environmental hazard or when average wind speed exceeds 10 miles per hour. Termiticide is not permitted to enter water systems, aquifers, or endanger humans or animals.

1.7 WARRANTY

Provide a 5 year written warranty against infestations or reinfestations by subterranean termites of the buildings or building additions constructed under this contract. Include in the warranty annual inspections of the buildings or building additions during the warranty period. If live subterranean termite infestation or subterranean termite damage is discovered during the warranty period, and the soil and building conditions have not been altered in the interim:

A. Retreat the site and perform other treatment as may be necessary for elimination of subterranean termite infestation;

B. Repair damage caused by termite infestation; and

C. Reinspect the building approximately 180 days after the re-treatment.

PART 2 PRODUCTS

2.1 SYSTEM DESCRIPTION

Chemical termite control uses liquid termiticide treatments applied to the soil to form a continuous chemical barrier in the soil around both sides of the foundation. The application can be surface applied or rodded and trenched. This barrier prevents foraging termites from reaching the foundation and piers. Only the soil adjacent to these foundation elements is treated. For slab construction (including foundations, patios and garages), the entire soil (or gravel) surface is treated before the vapor barrier is installed and the slab poured over it. Soil treatment is coordinated with all building activities from foundation construction through final grading of the soil around the building's exterior.

In order for the treatment to be effective, the final phase of the application must be done after final grading and sometimes after landscaping is completed so that the treated soil is not disturbed.

2.2 MATERIALS

A. Termiticides

Provide termiticides currently registered by the EPA or approved for such use by the appropriate agency of the host county and as approved by the Contracting Officer’s

Representative (COR). Select non-repellant termiticides for maximum effectiveness and duration after application. Select a termiticide that is suitable for the soil and climatic conditions at the project site and apply at the highest labeled rate. Submit manufacturer's label and Safety Data Sheet (SDS) for termiticides proposed for use.

PART 3 EXECUTION

3.1 PREPARATION

Eliminate food sources by removing debris from clearing and grubbing and post construction wood scraps such as ground stakes, form boards, and scrap lumber from the site, before termiticide application begins.

A. Verification

Before work starts, verify that final grades are as indicated and smooth grading has been completed in accordance with Section 31 00 00 EARTHWORK. Finely grade soil and remove particles larger than 1 inch. Compact soil particles to eliminate soil movement.

B. Foundation Exterior

If the exterior perimeter treatment is applied when the horizontal barrier is applied it will be damaged or removed before construction is completed. The exterior foundation perimeter treatment will have to occur in phases when any pads, porches, aprons, sidewalks, final grading or landscape planting are simultaneously involved adjacent to the building foundation. This treatment area should be coordinated after all major construction but before any pads, porches, or other items requiring special consideration are poured adjacent to the foundation walls. Submit written verification that final grading, landscape planting and other items adjacent to the foundation will not disturb treatment of the soil on the exterior sides of foundation walls, grade beams, and similar structures.

C. Utilities and Vents

Turn off and block HVAC ducts and vents located in treatment area prior to application, to protect people and animals from termiticide. Submit written verification that the HVAC ducts and vents, water and sewer lines, and plumbing have been turned off or blocked prior to applying termiticide.

file:///C:/USERS/THUFFMAN/DOCUMENTS/SPECSINTACTWD/Jobs/1009606/prntdata/Word/31%2000%2000.docx

D. Crawl and Plenum Air Spaces

Submit written verification that crawl and plenum air spaces have been located and identified prior to applying termiticide.

E. Application Plan

Prior to commencing application of termiticide, submit a Termiticide Application

Plan addressing the following items:

1. proposed sequence of treatment work including dates and times of application

2. termiticide trade name

3. EPA registration number

4. chemical composition

5. concentration of original and diluted material

6. formulation

7. manufacturer's recommended application rates

8. regional requirements

9. application rate of active ingredients

10. method of application

11. area or volume to be treated

12. amount to be applied

13. copy of the pest control business license

14. copy of the pesticide applicator certificates

3.2 APPLICATION

For areas to be treated, establish complete and unbroken vertical and horizontal soil poison barriers between the soil and all portions of the intended structure which may allow termite access to wood and wood related products. Make applications to crawl spaces in accordance with label directions. Applications to crawl space areas that are used as plenum air spaces will not be permitted.

A. Equipment Calibration and Tank Measurement

Submit a list of equipment to be used. Conduct calibration test on the application equipment to be used immediately prior to commencement of termiticide application.

Measure the volume and contents of the application tank. Testing must confirm that the application equipment is operating within the manufacturer's specifications and meets the specified requirements. Submit written certification of the equipment calibration test results within 1 week of testing. Where results from the equipment calibration and tank measurements tests are unsatisfactory, re-treatment will be required.

B. Mixing and Application

Perform all work related to formulating, mixing, and application in the presence of the Contracting Officer’s Representative (COR) and a DOD certified pesticide applicator, Pest Management QAE/PAR, or Integrated Pest Management

Coordinator. Submit mixing formulation:

Quantity of pesticide used.

Rate of dispersion.

Percent of use.

Total amount used.

A closed system is recommended as it prevents the termiticide from coming into contact with the applicator or other persons. Only use water from designated locations. Fit filling hoses with a backflow preventer meeting local plumbing codes or standards. Prevent overflow during the filling operation. Spill kits must be maintained on pest control vehicles and must be available at the mixing site.

Termiticide mixing must be conducted in an area that has been designated by the

Government representative and that has adequate spill containment. Inspect the application equipment for applying termiticides prior to each day of use for leaks, clogging, wear, or damage. Immediately perform repairs on the application equipment to prevent or eliminate leaks and clogging.

1. Application Method

a. Rodding and Trenching

Use rodding and trenching for establishing vertical soil barriers. Trenching must be to the depth of the foundation footing. Width of trench must be as recommended by the manufacturer, or as indicated. Rodding or other approved method may be implemented for saturating the base of the trench with termiticide. Backfill the trench immediately after termiticide has reached maximum penetration as recommended by the manufacturer. If maximum penetration is not achieved, as recommended by the manufacturer, repeat work performed to maximum penetration as recommended by the manufacturer at no additional cost to the Government. Backfill in 6 inch rises or layers. Treat each rise or layer with termiticide.

C. Sampling

The Contracting Officer may draw samples for analysis, at any time and without prior notice, from stocks at the job site to determine if the amount of active ingredient specified on the label is being applied. When analysis, performed by the Government, indicates samples contain less than the amount of active ingredient specified on the label, repeat work performed with pesticides conforming to this specification at no additional cost to the Government.

D. Vapor Barriers and Waterproof Membranes

Apply termiticide prior to placement of a vapor barrier or waterproof membrane.

E. Placement of Concrete

Place concrete covering treated soils as soon as the termiticide has reached maximum penetration into the soil as recommended by the manufacturer.

F. Clean Up, Disposal, And Protection

Once application has been completed, proceed with clean up and protection of the site without delay.

1. Clean Up

Clean the site of all material associated with the treatment measures, according to label instructions, and as indicated. Remove and dispose of excess and waste material off Government property.

2. Disposal of Termiticide

Dispose of residual termiticides and containers off Government property, and in accordance with label instructions and EPA criteria.

3.3 FIELD QUALITY CONTROL

A. Verification of Measurement

Once termiticide application has been completed, measure tank contents to determine the remaining volume. The total volume measurement of used contents for the application must equal the application rate established in the application plan. Submit written verification that the volume of termiticide used meets the application rate established in the application plan.

B. Inspection

1. Technical Representative

Provide a technical representative who is a DOD certified pesticide applicator or

Pest Management Quality Assurance Evaluator (QAE)/Performance Assessment

Representative (PAR). The technical representative must be present at all meetings concerning treatment measures for subterranean termites and during treatment application. Contact the Integrated Pest Management Coordinator prior to starting work.

3.4 CLOSEOUT ACTIVITIES

Upon completion of this work, submit the Pest Management Report DD Form 1532, or an equivalent computer product, to the Integrated Pest Management Coordinator. This form identifies the target pest, type of operation, brand name and manufacturer of pesticide, formulation, concentration or rate of application used.

3.5 PROTECTION

A. Protection of Treated Area

Immediately after the application, protect the area from other use by erecting barricades as required or directed. Provide signage in accordance with Section 10 14

00.10 EXTERIOR SIGNAGE. Place signage inside the entrances to crawl spaces and identify the space as treated with termiticide and not safe for children or animals.

Cover treated areas with plastic if slab is not to be poured immediately following termiticide application.

B. Disturbance of Treated Soils

Re-treat soil and fill material disturbed after treatment before placement of slabs or other covering structures.