J-9 Drawings_032224.pdf
PDF 45 MB Posted
- Attached to
- B2621 Dorm Construction Renovations
- Solicitation number
- FA448425R0001
About this file
This document appears to be a Request for Proposal (RFP) for a dorm renovation project at Joint Base McGuire-Dix-Lakehurst (JB MDL) in New Jersey. The work includes demolition, construction, renovation, and related work for 62 bedrooms and 24,530 square feet of living space. The renovation will involve relocating hot water and HVAC systems, refurbishing bathrooms and bedrooms, upgrading the fire alarm system, and hazardous material remediation. There is one bid option that encompasses the entire dorm renovation. Funds are not currently available, and the government reserves the right to cancel the solicitation. For instructions to offerors and the basis of award, see the respective attachments J-12 Section L and J-13 Section M.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U.S. AIR FORCE
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
Philadelphia District
FA8903-21-D0004
PTFL 22-1019
F A
-2
-D
P T
F L
-1
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-G
.r v t
/2
/2
:0
:4
P
M
G-001
C O
V E
R S
H E
E T
E A
D A
M S
O N
E A
D A
M S
O N
B S
C -J
V
K L
IE
B M
A N
N
M
A R
C H
22 MARCH 2024
MCGUIRE AFB, NEW JERSEY
RENOVATION OF DORMITORY BUILDING 2621
100% FINAL DESIGN SUBMITTAL
LOCATION MAP
VICINITY MAP
PROJECT LOCATION
PROJECT LOCATION B2621
3.22.2023
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
F A
-2
-D
P T
F L
-1
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-G
.r v t
/2
/2
:0
:4
P
M
G-002
S H
E E
T I
N D
E X
E A
D A
M S
O N
E A
D A
M S
O N
B S
C -J
V
K L
IE
B M
A N
N
M
A R
C H
F
IN
A L D
E S
IG
N
S U
B M
IT
T
A L
SHEET LIST
SHEET NUMBER SHEET TITLE
GENERAL
G-001 COVER SHEET
G-002 SHEET INDEX
G-003 LIFE SAFETY CODE NARRATIVE
G-004 LIFE SAFETY CODE NARRATIVE
G-101 LIFE SAFETY PLAN - FIRST FLOOR - COMPREHENSIVE
G-102 LIFE SAFETY PLAN - SECOND FLOOR - COMPREHENSIVE
G-103 LIFE SAFETY PLAN - THIRD FLOOR - COMPREHENSIVE
G-104 LIFE SAFETY OCCUPANT LOAD PLAN - FIRST FLOOR - AREA A
G-105 LIFE SAFETY OCCUPANT LOAD PLAN - FIRST FLOOR - AREA B
G-106 LIFE SAFETY OCCUPANT LOAD PLAN - FIRST FLOOR - LAUNDRY
G-107 LIFE SAFETY OCCUPANT LOAD PLAN - SECOND FLOOR - AREA A
G-108 LIFE SAFETY OCCUPANT LOAD PLAN - SECOND FLOOR - AREA B
G-109 LIFE SAFETY OCCUPANT LOAD PLAN - THIRD FLOOR - AREA A
G-110 LIFE SAFETY OCCUPANT LOAD PLAN - THIRD FLOOR - AREA B
CIVIL
C-001 CIVIL NOTES
C-002 CIVIL LEGEND
C-003 HAUL ROUTE AND LAYDOWN AREA
CD101 CIVIL DEMOLITION PLAN
CS101 SITE PLAN
CS102 DIMENSION CONTROL PLAN
CG101 GRADING PLAN
CU101 CIVIL UTILITIES PLAN
C-501 CIVIL DETAILS
C-502 CIVIL DETAILS
STRUCTURAL
S-001 DESIGN CRITERIA, GENERAL NOTES AND SCHEDULES
S-002 STRUCTURAL ABBREVIATIONS AND SYMBOLS
SB100 COMPREHENISVE - FOUNDATION PLAN
SF120 COMPREHENSIVE - 2ND AND 3RD FLOOR FRAMING PLANS
SF130 COMPREHENSIVE - ROOF FRAMING PLAN
S-301 HVAC DUNNAGE SECTIONS
S-302 SLAB REINFORCEMENT DETAILS
S-401 HVAC DUNNAGE ENLARGED PLANS
S-410 ENLARGED FRAMING PLANS
S-501 TYPICAL FOUNDATION DETAILS
S-502 FRAMING TYPICAL DETAILS
S-601 STRUCTURAL SCHEDULES
S-701 LOAD DIAGRAMS
ARCHITECTURE
A-001 ARCHITECTURAL GENERAL NOTES, MATERIAL AND ANNOTATION LEGEND
A-002 TYPICAL ADA DETAILS
AD-110 DEMOLITION - 1ST FLOOR COMPREHENSIVE PLAN
AD-120 DEMOLITION - 2ND FLOOR COMPREHENSIVE PLAN
AD-130 DEMOLITION - 3RD FLOOR COMPREHENSIVE PLAN
AD-210 DEMOLITION - REFLECTED CEILING PLAN - 1ST FLOOR COMPREHENSIVE PLAN
AD-220 DEMOLITION - REFLECTED CEILING PLAN - 2ND FLOOR COMPREHENSIVE PLAN
AD-230 DEMOLITION - REFLECTED CEILING PLAN - 3RD FLOOR COMPREHENSIVE PLAN
A-110 COMPREHENSIVE - 1ST FLOOR PLAN
A-111 1ST FLOOR PLAN - AREA A
A-112 1ST FLOOR PLAN - AREA B
A-120 COMPREHENSIVE - 2ND FLOOR PLANS
A-121 2ND FLOOR PLAN - AREA A
A-122 2ND FLOOR PLAN - AREA B
A-130 COMPREHENSIVE - 3RD FLOOR PLANS
A-131 3RD FLOOR PLAN - AREA A
A-132 3RD FLOOR PLAN - AREA B
A-140 ROOF PLAN
A-150 DUNNAGE PLAN AND ELEVATIONS
A-151 DUNNAGE ELEVATION AND DETAILS
AR-110 COMPREHENSIVE - 1ST FLOOR REFLECTED CEILING PLANS
AR-111 REFLECTED CEILING PLAN - 1ST FLOOR - AREA A
AR-112 REFLECTED CEILING PLAN - 1ST FLOOR - AREA B
AR-120 COMPREHENSIVE - 2ND FLOOR REFLECTED CEILING PLANS
AR-121 REFLECTED CEILING PLAN - 2ND FLOOR - AREA A
AR-122 REFLECTED CEILING PLAN - 2ND FLOOR - AREA B
AR-130 COMPREHENSIVE - 3RD FLOOR REFLECTED CEILING PLANS
AR-131 REFLECTED CEILING PLAN - 3RD FLOOR - AREA A
AR-132 REFLECTED CEILING PLAN - 3RD FLOOR - AREA B
A-201 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-401 ENLARGED BATHROOM PLANS
A-402 ENLARGED PLANS
A-410 INTERIOR ELEVATIONS
A-411 INTERIOR ELEVATIONS
A-501 CEILING DETAILS
A-601 PARTITION TYPES
A-611 DOOR TYPES AND DETAILS
A-612 DOOR SCHEDULE
A-701 CASEWORK SECTIONS
INTERIORS
IN110 INTERIOR FINISH - INTERIOR MATERIAL AND COLOR BASIS OF DESIGN AND NOTES
IN112 INTERIOR FINISH AND SIGNAGE - 1ST FLOOR PLAN - AREA A
IN113 INTERIOR FINISH AND SIGNAGE - 1ST FLOOR PLAN - AREA B
IN121 INTERIOR FINISH AND SIGNAGE - 2ND FLOOR PLAN - AREA A
IN122 INTERIOR FINISH AND SIGNAGE - 2ND FLOOR PLAN - AREA B
IN131 INTERIOR FINISH AND SIGNAGE - 3RD FLOOR PLAN - AREA A
IN132 INTERIOR FINISH AND SIGNAGE - 3RD FLOOR PLAN - AREA B
IN501 INTERIOR FINISH - DETAILS
IG501 SIGNAGE - DETAILS AND NOTES
IG601 SIGNAGE - SCHEDULES
IF110 INTERIOR FURNITURE - NOTES, LEGEND AND ENLARGED FURNITURE PLAN
IF111 COMPREHENSIVE OVERALL - INTERIOR FURNITURE - 1ST FLOOR PLAN
IF112 INTERIOR FURNITURE - 1ST FLOOR PLAN - AREA A
IF113 INTERIOR FURNITURE - 1ST FLOOR PLAN - AREA B
IF120 COMPREHENSIVE OVERALL - INTERIOR FURNITURE - 2ND FLOOR PLAN
IF121 INTERIOR FURNITURE - 2ND FLOOR PLAN - AREA A
IF122 INTERIOR FURNITURE - 2ND FLOOR PLAN - AREA B
IF130 COMPREHENSIVE OVERALL - INTERIOR FURNITURE - 3RD FLOOR PLAN
IF131 INTERIOR FURNITURE - 3RD FLOOR PLAN - AREA A
IF132 INTERIOR FURNITURE - 3RD FLOOR PLAN - AREA B
SHEET LIST
SHEET NUMBER SHEET TITLE
FIRE PROTECTION
FA001 FIRE ALARM & MASS NOTIFICATION GENERAL NOTES
FA101 FIRE ALARM & MASS NOTIFICATION AUDIBILITY PLAN - FIRST FLOOR - COMPREHENSIVE
FA102 FIRE ALARM & MASS NOTIFICATION AUDIBILITY PLAN - SECOND FLOOR - COMPREHENSIVE
FA103 FIRE ALARM & MASS NOTIFICATION AUDIBILITY PLAN - THIRD FLOOR - COMPREHENSIVE
FA104 FIRE ALARM & MASS NOTIFICATION PLAN - FIRST FLOOR - AREA A
FA105 FIRE ALARM & MASS NOTIFICATION PLAN - FIRST FLOOR - AREA B
FA106 FIRE ALARM & MASS NOTIFICATION PLAN - FIRST FLOOR - LAUNDRY
FA107 FIRE ALARM & MASS NOTIFICATION PLAN - SECOND FLOOR - AREA A
FA108 FIRE ALARM & MASS NOTIFICATION PLAN - SECOND FLOOR - AREA B
FA109 FIRE ALARM & MASS NOTIFICATION PLAN - THIRD FLOOR - AREA A
FA110 FIRE ALARM & MASS NOTIFICATION PLAN - THIRD FLOOR - AREA B
FA111 FIRE ALARM & MASS NOTIFICATION PLAN - ATTIC - AREA A
FA112 FIRE ALARM & MASS NOTIFICATION PLAN - ATTIC - AREA B
PLUMBING
P-001 PLUMBING GENERAL NOTES & LEGEND
PD101 PLUMBING DEMOLITION PLAN - FIRST FLOOR & MECH ROOM
PD102 PLUMBING DEMOLITION PLAN - SECOND FLOOR
PD103 PLUMBING DEMOLITION PLAN - THIRD FLOOR
PL101A DOMESTIC WATER PLAN - FIRST FLOOR - AREA A
PL101B DOMESTIC WATER PLAN - FIRST FLOOR - AREA B
PL102A DOMESTIC WATER PLAN - SECOND FLOOR - AREA A
PL102B DOMESTIC WATER PLAN - SECOND FLOOR - AREA B
PL103A DOMESTIC WATER PLAN - THIRD FLOOR - AREA A
PL103B DOMESTIC WATER PLAN - THIRD FLOOR - AREA B
PW101A SANITARY & WASTE PLAN - FIRST FLOOR - AREA A
PW101B SANITARY & WASTE PLAN - FIRST FLOOR - AREA B
PW102A SANITARY & WASTE PLAN - SECOND FLOOR - AREA A
PW102B SANITARY & WASTE PLAN - SECOND FLOOR - AREA B
PW103A SANITARY & WASTE PLAN - THIRD FLOOR - AREA A
PW103B SANITARY & WASTE PLAN - THIRD FLOOR - AREA B
P-104 PLUMBING ROOF PLAN
P-401 SUPPLY AND WASTE - TYPICAL ROOMS A
P-402 SUPPLY AND WASTE - TYPICAL ROOMS B & C
P-501 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
P-701 SANITARY WASTE & VENT RISER DIAGRAM
P-702 DOMESTIC WATER RISER DIAGRAM
MECHANICAL
M-001 MECHANICAL GENERAL NOTES & LEGEND
MD101 MECHANICAL DEMOLITION PLAN - FIRST FLOOR & MECH ROOM
MD102 MECHANICAL DEMOLITION PLAN - SECOND FLOOR
MD103 MECHANICAL DEMOLITION PLAN - THIRD FLOOR
MH101A VENTILATION PLAN - FIRST FLOOR - AREA A
MH101B VENTILATION PLAN - FIRST FLOOR - AREA B
MH102A VENTILATION PLAN - SECOND FLOOR - AREA A
MH102B VENTILATION PLAN - SECOND FLOOR - AREA B
MH103A VENTILATION PLAN - THIRD FLOOR - AREA A
MH103B VENTILATION PLAN - THIRD FLOOR - AREA B
MH104 VENTILATION PLAN - ATTIC
MP101A PIPING PLAN - FIRST FLOOR - AREA A
MP101B PIPING PLAN - FIRST FLOOR - AREA B
MP102A PIPING PLAN - SECOND FLOOR - AREA A
MP102B PIPING PLAN - SECOND FLOOR - AREA B
MP103A PIPING PLAN - THIRD FLOOR - AREA A
MP103B PIPING PLAN - THIRD FLOOR - AREA B
M-401 ENLARGED PLANS - TYPICAL ROOMS A
M-402 ENLARGED PLANS - TYPICAL ROOMS B & C
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-601 MECHANICAL VENTILATION TABLE
M-602 MECHANICAL SCHEDULES
M-701 MECHANICAL FLOW DIAGRAMS
M-702 MECHANICAL FLOW DIAGRAMS
M-703 MECHANICAL CONTROLS
M-704 MECHANICAL CONTROLS
M-705 HYDRONIC RISER DIAGRAM
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES & LEGEND
E-002 LIGHT FIXTURE AND MECHANICAL EQUIPMENT SCHEDULES
ED101 LIGHTING AND POWER - DEMOLITION PLAN - FIRST FLOOR
ED102 LIGHTING AND POWER - DEMOLITION PLAN - SECOND FLOOR
ED103 LIGHTING AND POWER - DEMOLITION PLAN - THIRD FLOOR
ED104 LIGHTING AND POWER - DEMOLITION PLAN - MECHANICAL ROOM & LAUNDRY
ED601 EXISTING RISER DIAGRAM - DEMOLITION
EL101A LIGHTING PLAN - FIRST FLOOR - AREA A
EL101B LIGHTING PLAN - FIRST FLOOR - AREA B
EL102A LIGHTING PLAN - SECOND FLOOR - AREA A
EL102B LIGHTING PLAN - SECOND FLOOR - AREA B
EL103A LIGHTING PLAN - THIRD FLOOR - AREA A
EL103B LIGHTING PLAN - THIRD FLOOR - AREA B
EP101A POWER PLAN - FIRST FLOOR - AREA A
EP101B POWER PLAN - FIRST FLOOR - AREA B
EP102A POWER PLAN - SECOND FLOOR - AREA A
EP102B POWER PLAN - SECOND FLOOR - AREA B
EP103A POWER PLAN - THIRD FLOOR - AREA A
EP103B POWER PLAN - THIRD FLOOR - AREA B
E-401 LIGHTING AND POWER - TYPICAL ROOMS A
E-402 LIGHTING AND POWER - TYPICAL ROOMS B & C
E-601 RISER DIAGRAM
E-602 PANEL SCHEDULES
E-603 PANEL SCHEDULES
E-604 PANEL SCHEDULES
E-605 PANEL SCHEDULES
E-606 PANEL SCHEDULES
E-701 LIGHTNING PROTECTION PLAN
E-702 LIGHTNING PROTECTION DETAILS
E-703 LIGHTNING PROTECTION DETAILS
E-801 ELECTRICAL DETAILS
E-802 ELECTRICAL DETAILS
SHEET LIST
SHEET NUMBER SHEET TITLE
TELECOMMUNICATIONS
T-001 TELECOMMUNICATIONS SYMBOLS, SCHEDULES, & NOTES
T-110 TELECOMMUNICATIONS - 1ST FLOOR - COMPREHENSIVE
T-111 TELECOMMUNICATIONS - 1ST FLOOR - AREA A
T-112 TELECOMMUNICATIONS - 1ST FLOOR - AREA B
T-120 TELECOMMUNICATIONS - 2ND FLOOR - COMPREHENSIVE
T-121 TELECOMMUNICATIONS - 2ND FLOOR - AREA A
T-122 TELECOMMUNICATIONS - 2ND FLOOR - AREA B
T-130 TELECOMMUNICATIONS - 3RD FLOOR - COMPREHENSIVE
T-131 TELECOMMUNICATIONS - 3RD FLOOR - AREA A
T-132 TELECOMMUNICATIONS - 3RD FLOOR - AREA B
T-401 TELECOMMUNICATIONS - ENLARGED PLANS
T-402 TELECOMMUNICATIONS - ENLARGED PLANS
T-403 TELECOMMUNICATIONS - ENLARGED PLANS
T-501 TELECOMMUNICATIONS - DETAILS
T-502 TELECOMMUNICATIONS - DETAILS
T-503 TELECOMMUNICATIONS - DETAILS
T-504 TELECOMMUNICATIONS - DETAILS
T-505 TELECOMMUNICATIONS - DETAILS
T-601 TELECOMMUNICATIONS - DIAGRAMS
T-602 TELECOMMUNICATIONS - DIAGRAMS
3.22.2023
ENGINEERING AND CONSTRUCTION BULLETIN (ECB) 2018-17 – REV 1, MAY 14 2020 - CHANGE 1
INTERNATIONAL BUILDING CODE (IBC), 2024 EDITION
NFPA 1: FIRE CODE, 2024 EDITION
NFPA 10: STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2022 EDITION
NFPA 70: NATIONAL ELECTRICAL CODE, 2023 EDITION
GENERAL INFORMATION:
PROPERTY NAME & PHYSICAL ADDRESS: RENOVATION/ADDITION OF DORM 2621
POW-MIA BLVD
MCGUIRE AIR FORCE BASE, NEW JERSEY
PROJECT CONSTRUCTION PURPOSE: RENOVATION/ADDITION
REASON FOR SUBMITTAL: CODE COMPLIANCE OF RENOVATED FACILITY
CRITERIA USED:
UFC 4-021-01: DESIGN AND O&M: MASS NOTIFICATION SYSTEMS APRIL 2008; CHANGE 1, JANUARY 2010
ANTICIPATED ADDITIONS: NO ADDITIONAL ADDITIONS
DATE DEVELOPED: MARCH 22, 2024
DATE MODIFIED: NONE
OWNER INFORMATION: USACE
CODE CONSULTANT INFORMATION: POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KS 66062
913.829.8650 (TELEPHONE)
913.829.8690 (TELEFAX)
DESIGNER’S SEAL: SEE TITLE BLOCK
FIRE SERVICE: MCGUIRE-DIX FIRE DEPARTMENT
LOCAL BUILDING INSPECTOR: MCGUIRE-DIX FIRE DEPARTMENT
ALLOWABLE AREA
(GROUP R-2)
16,000 FT2 MULTISTORY WITHOUT SPRINKLER
INCREASE
ACTUAL AREA - FIRST
FLOOR
8,330 FT2 - COMPLIANT*
* TOTAL BUILDING AREA: 24,530 FT2
AHJ APPROVED EQUIVALENCIES: B2621 DOES NOT CURRENTLY HAVE A FIRE SUPPRESSION SYSTEM.
PER UFC 3-600-01 SECTION 34-1.1, FACILITIES, AS THEY EXIST, MUST
MEET THE REQUIREMENTS OF NFPA 101 FOR EXISTING OCCUPANCIES.
THE EXISTING BUILDING DOES MEET THE REQUIREMENTS OF NFPA
101, CHAPTER 29 (EXISTING HOTELS AND DORMITORIES). THE
ESTIMATED COST OF THE PROJECT WILL BE LESS THAN 50% OF THE
BUILDING’S REPLACEMENT VALUE, PER UFC 3-600-01, SECTION 34-1.2.9.
THEREFORE, THIS PROJECT DOES NOT MEET THE THRESHOLD TO
REQUIRE ADDING AN AUTOMATIC SPRINKLER SYSTEM TO THE
BUILDINGS AND A SPRINKLER SYSTEM WILL NOT BE PROVIDED
INITIAL INTEGRATED PERFORMANCE
VERIFICATION AND TESTING PLAN(S):
ACCEPTANCE TESTING REQUIREMENTS ARE INCLUDED IN THE
PROJECT SPECIFICATIONS FOR EACH SYSTEM.
INCIDENTAL STORAGE (NFPA 101, SECTION 6.1.14.1.3)
TYPE OF CONSTRUCTION: TYPE IIB (IBC, TABLE 601)
STRUCTURAL CODE REQUIREMENTS: HEIGHT LIMITATION (IBC, TABLES 504.3 AND 504.4)
ALLOWABLE HEIGHT
RESIDENTIAL (GROUP
R-2)
4 STORIES, 55 FT.
ACTUAL HEIGHT 3 STORIES, 38 FT. - COMPLIANT
AREA LIMITATION (IBC, TABLE 506.2)
NFPA 72: NATIONAL FIRE ALARM AND SIGNALING CODE, 2022 EDITION
NFPA 80: STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES, 2022 EDITION
NFPA 90A: STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS, 2024 EDITION
NFPA 101: LIFE SAFETY CODE, 2024 EDITION
NFPA 170: STANDARD FOR FIRE SAFETY AND EMERGENCY SYMBOLS, 2024 EDITION
NFPA 291: STANDARD RECOMMENDED PRACTICE FOR FIRE FLOW TESTING AND MARKING OF HYDRANTS, 2022 EDITION
UFC 1-200-01: DOD BUILDING CODE, 01 SEPTEMBER 2022; CHANGE 2, 12 JUNE 2023
UFC 3-600-01: FIRE PROTECTION ENGINEERING FOR FACILITIES 8 AUGUST 2016; CHANGE 6, 6 MAY 2021
UFC 4-010-01: DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS 12 DECEMBER 2018; CHANGE 1, 19 AUGUST 2020
AUTHORITY HAVING JURISDICTION: CONSTRUCTION USACE
OCCUPANCY GROUP AND TYPE: IBC OCCUPANCY:
SINGLE OCCUPANCY (IBC, SECTION 506.2.1)
RESIDENTIAL (GROUP R-2) (IBC, SECTION 310.3)
ACCESSORY STORAGE (GROUP S-1) (IBC, SECTION 508.2)
NFPA 101 OCCUPANCY:
SINGLE OCCUPANCY (NFPA 101, SECTION 6.1.14.3)
EXISTING HOTEL AND DORMITORIES (NFPA 101, SECTION 6.1.11)
FIRE COMMAND CENTER: NOT REQUIRED (UFC 3-600-01 & NFPA 101) - NOT PROVIDED
36 IN. CLEAR SPACE AROUND CIRCUMFERENCE OF FIRE
HYDRANTS REQUIRED (NFPA 1, SECTION 18.5.7.1) - EXISTING
PROVIDED
FIRE SERVICE FEATURES:
FIRE DEPARTMENT ACCESS: AT LEAST ONE MEANS OF ALL-WEATHER GROUND ACCESS NO
FARTHER THAN 33 FT. FROM AN EXTERIOR DOOR ACCESSIBLE
FOR FIRE DEPARTMENT INGRESS REQUIRED (UFC 3-600-01,
SECTION 9-1.1) - EXISTING PROVIDED
FIRE DEPARTMENT ACCESS ROADS SUCH THAT ANY PORTION
OF THE FACILITY OR ANY PORTION OF AN EXTERIOR WALL OF
THE FIRST STORY OF THE BUILDING IS LOCATED NOT MORE
THAN 150 FT. FROM FIRE DEPARTMENT ACCESS ROADS
REQUIRED (NFPA 1, SECTION 18.2.3.2.2) - EXISTING PROVIDED
FIRE APPARATUS ACCESS ROADS MUST HAVE AN
UNOBSTRUCTED WIDTH OF NOT LESS THAN 20 FT. AND AN
UNOBSTRUCTED VERTICAL CLEARANCE OF NOT LESS THAN 13.5
FT. REQUIRED (NFPA 1, SECTION 18.2.3.5) - EXISTING PROVIDED
HEIGHT TO THE CENTER OF A HOSE OUTLET GREATER THAN OR
EQUAL TO 18 IN. ABOVE FINAL GRADE REQUIRED (UFC 3-600-01,
SECTION 9-3.5.7.d AND NFPA 24, SECTION 7.3.3) - PROVIDED
A SUFFICIENT NUMBER OF HYDRANTS MUST BE PROVIDED SO
THAT FIRE FLOW CAN BE MET WITHOUT TAKING MORE THAN
1,250 GPM FROM ANY SINGLE HYDRANT REQUIRED (UFC
3-600-01, SECTION 9-3.5.8.1) - EXISTING PROVIDED
FORCE PROTECTION EQUIPMENT ARRANGED TO NOT REQUIRE
MORE THAN ONE PERSON TO REMOVE OR OPEN REQUIRED
(UFC 3-600-01, SECTION 9-1.3) - PROVIDED
LOCKING DEVICES CONTROLLING VEHICLE ACCESS UNDER
CONTROL OF FIRE DEPARTMENT REQUIRED (UFC 3-600-01,
SECTION 9-1.3) - PROVIDED
ACCESS BOX: REQUIRED (NFPA 1, SECTION 18.2.2.1) - PROVIDED
FIRE HYDRANTS: FIRE HYDRANT SPACING SUCH THAT ALL PARTS OF THE
BUILDING EXTERIOR ARE WITHIN 350 FT OF A FIRE HYDRANT
REQUIRED (UFC 3-600-01, SECTION 9-3.5.8.2) - EXISTING
PROVIDED
PHYSICAL PROTECTION FOR FIRE HYDRANTS THAT ARE
SUBJECT TO IMPACT BY A MOTOR VEHICLE REQUIRED (UFC
3-600-01, SECTION 9-3.5.9) - EXISTING PROVIDED
FIRE SAFETY AND EVACUATION PLANS: REQUIRED (UFC 3-600-01, SECTION 10-1.1 & NFPA 101, SECTION
29.7.4) - PROVIDED
RESIDUAL: 64 PSI
DATE: JULY 18, 2023
FLOW: 1672 GPM
FLOW AT 20 PSI RESIDUAL: 5,735 GPM
LOCATION: HYDRANTS NORTH OF BUILDING OFF
OF TUSKEGEE AIRMEN BLVD
STATIC: 69 PSI
FIRE WATER DEMAND: NOT APPLICABLE, BUILDING IS NONSPRINKLERED
FIRE FLOW: 3,250 GPM AT 20 PSI REQUIRED (UFC 3-600-01, SECTION 9-2.1 AND
NFPA 1, TABLE 18.4.5.2.1) - PROVIDED
WATER SUPPLY REQUIREMENTS:
FIRE HYDRANT FLOW TEST (HISTORICAL): SOURCE: POOLE FIRE PROTECTION, INC.
ALL INSTALLATION OF FIRE RATED DOORS/WINDOWS SHALL BE INSTALLED AS PER NFPA 80
REQUIRED - PROVIDED
ALL INSTALLATION OF EXIT DOORS, PANIC HARDWARE, EXIT LIGHTS, EMERGENCY LIGHTING,
AND INTERIOR FINISH SHALL BE PERFORMED AS PER NFPA 101- LIFE SAFETY CODE REQUIRED -
PROVIDED
PASSIVE FIRE SAFETY FEATURES:
FIRE BARRIER AND OCCUPANCY SEPARATION: 1-HR FIRE BARRIER REQUIRED (NFPA 101, SECTION 4.6.7.5, 28.3.7.1) - PROVIDED
PROTECTION OF HAZARDOUS AREAS: 1-HR FIRE BARRIER FOR ROOMS ENCLOSING FUEL-FIRED EQUIPMENT ROOMS AND LARGE STORAGE
ROOMS (NFPA 101, TABLE 29.3.2.2.2) - PROVIDED
FIRE-RESISTANT JOINT SYSTEMS REQUIRED, PROVIDED
PROTECTION OF HORIZONTAL AND VERTICAL
PENETRATIONS:
THROUGH PENETRATIONS OF FIRE RESISTANCE RATED CONSTRUCTION PROTECTED BY AN
APPROVED FIRE STOP SYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E814 OR UL
1479 REQUIRED (IBC, SECTION 714.4.1.2 AND NFPA 101, SECTION 8.3.4.2) - PROVIDED
BUILDING SEPARATION AND EXPOSURE
PROTECTION:
BUILDING PROTECTION NOT REQUIRED AS BUILDING IS AT LEAST 30 FEET FROM OTHER
BUILDINGS (IBC, TABLE 602) - NOT PROVIDED
EXIT ACCESS CORRIDORS: 1-HR FIRE BARRIER REQUIRED (NFPA 101, SECTIONS 4.6.7.5, 28.3.6.1.2) - PROVIDED AS BUILDING
IS NOT PROVIDED WITH AN AUTOMATIC SPRINKLER SYSTEM
FIRE RESISTIVE REQUIREMENTS: FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (IBC, TABLES 601 & 602)
PRIMARY STRUCTURAL FRAME 0-HOUR REQUIRED - PROVIDED
BEARING WALLS - EXTERIOR 0-HOUR REQUIRED - PROVIDED
INTERIOR FINISH: INTERIOR FINISH REQUIREMENTS PER OCCUPANCY CLASSIFICATION (NFPA 101, SECTIONS 10.2.7.1, 10.2.7.2, AND 28.3.3) - PROVIDED
OCCUPANCY TYPE
INTERIOR WALL AND
CEILING FINISHES IN
EXITS AND EXIT ACCESS
CORRIDORS
INTERIOR WALL
AND CEILING
FINISHES IN
OTHER AREAS
INTERIOR FLOOR
FINISHES IN EXIT
ENCLOSURES
INTERIOR FLOOR
FINISHES IN OTHER
AREAS
HOTEL AND
DORMITORY
CLASS A OR B CLASS A, B, OR C CLASS I OR II
MEET ASTM D2859,
OR MINIMUM
CRITICAL RADIANT
FLUX OF 0.1 W/cm²
BEARING WALLS - INTERIOR 0-HOUR REQUIRED - PROVIDED
NON BEARING WALLS - EXTERIOR 0-HOUR REQUIRED - PROVIDED
NON BEARING WALLS - INTERIOR 0-HOUR REQUIRED - PROVIDED
FLOOR CONSTRUCTION AND SECONDARY MEMBERS 0-HOUR REQUIRED - PROVIDED
ROOF CONSTRUCTION AND SECONDARY MEMBERS 0-HOUR REQUIRED - PROVIDED
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
F A
-2
-D
P T
F L
-1
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-F
.r v t
/2
/2
:2
:5
P
M
G-003
L
IF
E S
A F
E T
Y C
O D
E N
A R
R A
T
IV
E
K B
O Y
E R
A S
T E
IN
W
A C
H S
B S
C -J
V
A P
O O
L E
M
A R
C H
F
IN
A L D
E S
IG
N
S U
B M
IT
T
A L
ACTIVE FIRE SAFETY FEATURES:
AUTOMATIC SPRINKLER SYSTEMS: REQUIRED (UFC 3-600-01, SECTION 9-7 AND 4-35.2 - NOT
PROVIDED
LOCATION OF FIRE DEPARTMENT
CONNECTIONS:
NOT APPLICABLE, BUILDING IS NONSPRINKLERED
EMERGENCY LIGHTING: REQUIRED (NFPA 101, SECTIONS 38.2.9.1 AND 40.2.9) - PROVIDED
MARKING OF MEANS OF EGRESS: REQUIRED (NFPA 101,SECTIONS 7.10, 38.2.10, AND 40.2.10) -
PROVIDED
EVACUATION DIAGRAM REQUIRED (NFPA 101, SECTION 7.10.8.5) -
NOT REQUIRED, NOT PROVIDED
FIRE PUMP: NOT REQUIRED (UFC 3-600-01, SECTION 9-5) - NOT PROVIDED
WATER SPRAY SYSTEMS: NOT REQUIRED (UFC 3-600-01, SECTION 9-8) - NOT PROVIDED
FOAM SYSTEMS: NOT REQUIRED (UFC 3-600-01, SECTION 9-9.1.1) - NOT PROVIDED
LOCATIONS OF POST INDICATOR VALVES (PIVS)
AND OTHER CONTROL OR ISOLATION VALVES:
NOT APPLICABLE, BUILDING IS NONSPRINKLERED
CONTROL VALVE ON EACH SERVICE LATERAL, DOWNSTREAM OF THE
CONNECTION TO THE SERVICE MAIN REQUIRED (UFC 3-600-01, SECTION
9-3.4.2) - EXISTING BUILDING, NOT IN SCOPE OF WORK FOR PROJECT
SECTIONAL VALVES ON SERVICE MAINS TO BE KEY-OPERATED
REQUIRED (UFC 3-600-01, SECTION 9-3.4.4) - EXISTING, PROVIDED
A UNDERGROUND GATE WILL BE LOCATED ON NEW
UNDERGROUND MAIN. THERE IS NO SPACE FOR A PIV VALVE.
REQUIRED (NFPA 24, SECTION 6.1.1.3) - EXISTING, PROVIDED
ANALYSIS OF AUTOMATIC SPRINKLER AND
SUPPRESSION SYSTEMS AND PROTECTED
AREAS:
WET PIPE SYSTEM REQUIRED (UFC 3-600-01, SECTION 9-7.1.2) -
NFPA 13R NOT PROVIDED
STANDPIPE SYSTEMS: NOT REQUIRED (UFC 3-600-01, SECTION 9-10) - NOT PROVIDED
DRY CHEMICAL EXTINGUISHING SYSTEMS: NOT REQUIRED (UFC 3-600-01, SECTION 9-11) - NOT PROVIDED
WET CHEMICAL EXTINGUISHING SYSTEMS: NOT REQUIRED (UFC 3-600-01, SECTION 9-12) - NOT PROVIDED
CLEAN AGENT FIRE EXTINGUISHING SYSTEMS: NOT REQUIRED (UFC 3-600-01, SECTION 9-13) - NOT PROVIDED
WATER MIST FIRE PROTECTION SYSTEMS: NOT REQUIRED (UFC 3-600-01, SECTION 9-14) - NOT PROVIDED
DUCT SMOKE DETECTION ON AIR HANDLING UNITS GREATER
THAN 15000 CFM RETURN AIR CAPACITY REQUIRED (NFPA 90A,
SECTION 6.4.2.1(2)) - PROVIDED
CARBON MONOXIDE DETECTION: REQUIRED (UFC 3-600-01, SECTION 9-19.1.1) - PROVIDED
SMOKE MANAGEMENT OR CONTROL METHODS: NOT REQUIRED (UFC 3-600-01, SECTION 9-20) - NOT PROVIDED
SECURITY AND ANTITERRORISM
REQUIREMENTS:
MASS NOTIFICATION SYSTEM REQUIRED (UFC 4-010-01, SECTION
1-5) - PROVIDED.
ILLUMINATION OF MEANS OF EGRESS: REQUIRED (NFPA 101, SECTIONS 38.2.8 AND 7.8) - PROVIDED
MASS NOTIFICATION SYSTEM: REQUIRED (UFC 4-010-01, SECTION 3-22) - PROVIDED
CONNECTION TO AND DESCRIPTION OF BASE
FIRE ALARM REPORTING SYSTEM:
REQUIRED (UFC 3-600-01, SECTION 9-18.3) - PROVIDED VIA
COMBINATION FIRE ALARM / MASS NOTIFICATION SYSTEM. THESE
SYSTEMS WILL REPORT TO CENTRAL STATION RECEIVING
STATION. AN CELLULAR FIRE ALARM COMMUNICATOR AND FIRE
ALARM CONTROL PANEL SHALL BE PROVIDED - PROVIDED.
SMOKE DETECTION:
SMOKE DETECTOR ABOVE FIRE ALARM CONTROL UNIT,
NOTIFICATION APPLIANCE CIRCUIT POWER EXTENDERS, AND
SUPERVISING STATION TRANSMITTING EQUIPMENT REQUIRED
(NFPA 72, SECTION 10.4.5) - PROVIDED
DUCT SMOKE DETECTION ON AIR HANDLING UNITS GREATER
THAN 2000 CFM SUPPLY AIR CAPACITY REQUIRED (NFPA 90A,
SECTION 6.4.2.1(1)) - PROVIDED
CARBON DIOXIDE SYSTEMS: NOT REQUIRED (UFC 3-600-01, SECTION 9-15) - NOT PROVIDED
HALON 1301 SYSTEMS: NOT PERMITTED (UFC 3-600-01, SECTION 9-16.1) - NOT PROVIDED
PORTABLE FIRE EXTINGUISHERS: REQUIRED (UFC 3-600-01, SECTION 9-17) - PROVIDED
FIRE ALARM SYSTEM: REQUIRED (UFC 3-600-01, SECTION 9-18.6.1) - PROVIDED
COMBINED FA/MNS SYSTEM
THE FIRE ALARM SYSTEM WIRING SHALL BE CLASS B FOR
SIGNALING LINE CIRCUITS AND CLASS B FOR NOTIFICATION
APPLIANCE CIRCUITS PER FBFES REVIEW COMMENTS
MEANS OF EGRESS:
OCCUPANT LOAD: CALCULATED OCCUPANT LOAD PER OCCUPANCY
CLASSIFICATION AND USE (NFPA 101, TABLE 7.3.1.2 AND UFC
3-600-01, TABLE 10-1) - PROVIDED
USE
OCCUPANT LOAD
FACTOR
GROSS OR
NET AREA
MECHANICAL,
ELECTRICAL, OR OTHER
BUILDING EQUIPMENT
SPACES
500 SQ.FT. PER PERSON GROSS
ASSEMBLY 15 SQ.FT. PER PERSON NET
HOTELS AND
DORMITORIES
200 SQ.FT. PER PERSON NET
IT EQUIPMENT ROOMS 300 SQ.FT. PER PERSON GROSS
STORAGE 500 SQ.FT. PER PERSON GROSS
TOTAL BUILDING OCCUPANT LOAD:
TOTAL OCCUPANT LOAD: 247
COMMON PATH OF TRAVEL: ALLOWABLE COMMON PATH OF TRAVEL
HOTELS AND
DORMITORIES
35 FT. (NFPA 101, 29.2.5.2.2)
ACTUAL
HOTELS AND
DORMITORIES
REFER TO LIFE SAFETY PLANS
DEAD-END CORRIDORS: ALLOWABLE DEAD-END CORRIDORS
HOTELS AND
DORMITORIES
50 FT. (NFPA 101, 29.2.5.3)
ACTUAL
HOTELS AND
DORMITORIES
REFER TO LIFE SAFETY PLANS
MAXIMUM TRAVEL DISTANCE: ALLOWABLE TRAVEL DISTANCE
HOTELS AND
DORMITORIES
75 FT. FROM DORM ROOM DOOR TO CORRIDOR
(NFPA 101, 29.2.6.1)
100 FT. FROM CORRIDOR DOOR TO
EXIT (NFPA 101, 29.2.6.3.1)
ACTUAL
HOTELS AND
DORMITORIES
REFER TO LIFE SAFETY PLANS
STAIRWAY DIMENSIONAL REQUIREMENTS: REQUIRED (NFPA 101, SECTION 7.2.2) - PROVIDED
RAMP REQUIREMENTS: NOT APPLICABLE
HANDRAIL REQUIREMENTS: REQUIRED (NFPA 101, SECTION 7.2.2.4) - PROVIDED
GUARD REQUIREMENTS: REQUIRED (NFPA 101, SECTION 7.2.2.4.6) - PROVIDED
NUMBER OF EXITS: TWO BUILDING EXITS REQUIRED (NFPA 101, SECTION 7.4.1.2(1)) - A MINIMUM
OF 2 TWO PROVIDED FROM EACH FLOOR
ARRANGEMENT OF EXITS: WHERE TWO EXITS OR EXIT ACCESS DOORWAYS ARE REQUIRED, EXITS
OR EXIT ACCESS DOORWAYS SEPARATED BY NOT LESS THAN ONE-HALF
THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE
AREA SERVED REQUIRED (NFPA 101, SECTION 7.5.1.3.3) - PROVIDED
MEANS OF EGRESS SIZING: CALCULATED MEANS OF EGRESS COMPONENTS SIZING REQUIREMENTS PER COMPONENT REQUIRED (NFPA 101, TABLES 7.3.3.1, 7.2.5.3(a), 7.2.2.2.1.2(A), AND 7.2.2.2.1.2(B) AND SECTIONS 7.2.1.2.3.2, 7.2.2.2.1.2(F), 7.2.6.4.2, AND 7.3.4) - PROVIDED
COMPONENT
SIZING FACTOR - LOW/ORDINARY
HAZARD
MINIMUM
SIZE
STAIRWAYS (2000
OCCUPANTS OR LESS)
0.3 INCHES PER PERSON 44 IN.
PASSAGEWAYS 0.2 INCHES PER PERSON 36 IN.
DOORS 0.2 INCHES PER PERSON 32 IN.
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
F A
-2
-D
P T
F L
-1
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-F
.r v t
/2
/2
:2
:5
P
M
G-004
L
IF
E S
A F
E T
Y C
O D
E N
A R
R A
T
IV
E
K B
O Y
E R
A S
T E
IN
W
A C
H S
B S
C -J
V
A P
O O
L E
M
A R
C H
F
IN
A L D
E S
IG
N
S U
B M
IT
T
L
MTD1.2
MTD1.1
BEDROOM
109 110
BEDROOM
110 111
BEDROOM
111 112
BEDROOM
112 113
BEDROOM
113 114
BEDROOM
114 118
BEDROOM
119N
ELEC
ROOM
119N
120N
MECH
ROOM
120N
BEDROOM
121 122
BEDROOM
122 123
BEDROOM
123 124
BEDROOM
BEDROOM
125126
BEDROOM
126127
BEDROOM
127128
BEDROOM
101B
STORAGE
101B
CL
130 129
CL
101A
STORAGE
101A
RESTROOM
STORAGE
101C001
ENTRANCE
CORRIDOR
C001
BEDROOM
104105
BEDROOM
105106
BEDROOM
106107
BEDROOM
BEDROOM
CORRIDOR
115N
TELECOM
115N
118A
BATHROOM
118A 121-22A
BATHROOM
121-22A 123-24A
BATHROOM
123-24A113-14A
BATHROOM
113-14A111-12A
BATHROOM
111-12A109-10A
BATHROOM
109-10A
107-8A
BATHROOM
107-8A 105-6A
BATHROOM
105-6A
104A
BATHROOM
104A
128-27A
BATHROOM
128-27A 125-26A
BATHROOM
125-26A
CPT1.1
B
CC C
B
SYMBOL
XX#.#
DESCRIPTION
PATH OF EGRESS
PATH OF EGRESS IDENTIFIER
LIFE SAFETY LEGEND
1-HOUR FIRE RATED BARRIER
PORTABLE FIRE EXTINGUISHER (BRACKET)B
PORTABLE FIRE EXTINGUISHER (CABINET)C
OCCUPANCY CLASSIFICATION LEGEND
RESIDENTIAL (RESIDENTIAL GROUP R-2)
DESCRIPTIONHATCH
A B
PLAN NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
F A
-2
-D
P T
F L
-1
KEYPLAN
GRAPHIC SCALE NORTH ARROW
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-F
.r v t
/2
/2
:2
:5
P
M
G-101
L
IF
E S
A F
E T
Y P
L A
N
F
IR
S T
F L O
O R
C
O M
P R
E H
E N
S
IV
E
K B
O Y
E R
A S
T E
IN
W
A C
H S
B S
C -J
V
A P
O O
L E
M
A R
C H
F
IN
A L D
E S
IG
N
S U
B M
IT
T
A L
SCALE = 3/32" = 1'-0"C2
LIFE SAFETY PLAN - FIRST FLOOR - COMPREHENSIVE
16'8' 32'0
SCALE: 3/32" = 1'-0"
DEC: DEAD-END CORRIDOR
MTD: MAXIMUM TRAVEL DISTANCE
CPT: COMMON PATH OF TRAVEL
TAG ABBREVIATIONS:
EGRESS PATH SCHEDULE-FIRST
FLOOR
TAG
ACTUAL
LENGTH OCCUPANCY
MAXIMUM
ALLOWABLE
LENGTH
CPT1.1 50' - 6" S 50' - 0"
CPT3.1 37' - 0" R 35' - 0"
MTD1.1 24' - 6" R 75' - 0"
MTD1.2 74' - 3" R 100' - 0"
MTD2.1 71' - 9" R 100' - 0"
MTD2.2 23' - 8" R 75' - 0"
MTD3.1 25' - 0" R 75' - 0"
MTD3.2 81' - 11" R 100' - 0"
MTD2.2
MTD2.1
BEDROOM
209 210
BEDROOM
210 211
BEDROOM
211 212
BEDROOM
212 213
BEDROOM
213 214
BEDROOM
214 218
BEDROOM
217N
STORAGE
217N
218A
BATHROOM
218A
215N
TELECOM
215N 219N
ELEC
219N
220A
BATHROOM
220A
BEDROOM
220 221
BEDROOM
221 222
BEDROOM
222 223
BEDROOM
221-22A
BATHROOM
221-22A
BEDROOM
223-24A
BATHROOM
223-24A
BEDROOM
225226
BEDROOM
226227
BEDROOM
227228
BEDROOM
228229
CL
226-25A
BATHROOM
226-25A228-27A
BATHROOM
228-27A
CORRIDOR
DAY
ROOM
STORAGE
JC
204A
BATHROOM
204A
BEDROOM
204206
BEDROOM
206 205
BEDROOM
205207
BEDROOM
BEDROOM
207-08A
BATHROOM
207-08A 205-6A
BATHROOM
205-6A
ST-A
STAIR A
ST-A
209-10A
BATHROOM
209-10A 211-12A
BATHROOM
211-12A 213-14A
BATHROOM
213-14A
LOUNGE /
CAFE
AREA
CL
CC C
SYMBOL
XX#.#
DESCRIPTION
PATH OF EGRESS
PATH OF EGRESS IDENTIFIER
LIFE SAFETY LEGEND
1-HOUR FIRE RATED BARRIER
PORTABLE FIRE EXTINGUISHER (BRACKET)B
PORTABLE FIRE EXTINGUISHER (CABINET)C
OCCUPANCY CLASSIFICATION LEGEND
RESIDENTIAL (RESIDENTIAL GROUP R-2)
DESCRIPTIONHATCH
A B
PLAN NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
F A
-2
-D
P T
F L
-1
KEYPLAN
GRAPHIC SCALE NORTH ARROW
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-F
.r v t
/2
/2
:2
:0
P
M
G-102
L
IF
E S
A F
E T
Y P
L A
N
S E
C O
N D
F L O
O R
C
O M
P R
E H
E N
S
IV
E
K B
O Y
E R
A S
T E
IN
W
A C
H S
B S
C -J
V
A P
O O
L E
M
A R
C H
F
IN
A L D
E S
IG
N
S U
B M
IT
T
A L
SCALE = 3/32" = 1'-0"C2
LIFE SAFETY PLAN - SECOND FLOOR - COMPREHENSIVE
16'8' 32'0
SCALE: 3/32" = 1'-0"
DEC: DEAD-END CORRIDOR
MTD: MAXIMUM TRAVEL DISTANCE
CPT: COMMON PATH OF TRAVEL
TAG ABBREVIATIONS:
EGRESS PATH SCHEDULE-FIRST
FLOOR
TAG
ACTUAL
LENGTH OCCUPANCY
MAXIMUM
ALLOWABLE
LENGTH
CPT1.1 50' - 6" S 50' - 0"
CPT3.1 37' - 0" R 35' - 0"
MTD1.1 24' - 6" R 75' - 0"
MTD1.2 74' - 3" R 100' - 0"
MTD2.1 71' - 9" R 100' - 0"
MTD2.2 23' - 8" R 75' - 0"
MTD3.1
MTD3.2
BEDROOM
309 310
BEDROOM
310 311
BEDROOM
311 312
BEDROOM
312 313
BEDROOM
313 314
BEDROOM
314 318
BEDROOM
315N
TELECOM
315N
317N
STORAGE
317N
319N
ELEC
319N
320A
BATHROOM
320A
BEDROOM
320 321
BEDROOM
321 322
BEDROOM
321-22A
BATHROOM
321-22A
BEDROOM
323 324
BEDROOM
323-24A
BATHROOM
323-24A
BEDROOM
325326
BEDROOM
326327
BEDROOM
327328
BEDROOM
CL
LOUNGE /
CAFE
AREA
CORRIDOR
326-25A
BATHROOM
326-25A328-27A
BATHROOM
328-27A
309-10A
BATHROOM
309-10A
308-07A
BATHROOM
308-07A
311-12A
BATHROOM
311-12A
305-6A
BATHROOM
305-6A
313-14A
BATHROOM
313-14A
ST-A
STAIR A
ST-A
JC
STORAGE
BEDROOM
306 305
BEDROOM
318A
BATHROOM
318A
304A
BATHROOM
304A
BEDROOM
BEDROOM
BEDROOM
330A
CL
330A
CPT3.1
CC C
SYMBOL
XX#.#
DESCRIPTION
PATH OF EGRESS
PATH OF EGRESS IDENTIFIER
LIFE SAFETY LEGEND
1-HOUR FIRE RATED BARRIER
PORTABLE FIRE EXTINGUISHER (BRACKET)B
PORTABLE FIRE EXTINGUISHER (CABINET)C
OCCUPANCY CLASSIFICATION LEGEND
RESIDENTIAL (RESIDENTIAL GROUP R-2)
DESCRIPTIONHATCH
A B
PLAN NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
F A
-2
-D
P T
F L
-1
KEYPLAN
GRAPHIC SCALE NORTH ARROW
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-F
.r v t
/2
/2
:2
:0
P
M
G-103
L
IF
E S
A F
E T
Y P
L A
N
T H
IR
D
F L O
O R
C
O M
P R
E H
E N
S
IV
E
K B
O Y
E R
A S
T E
IN
W
A C
H S
B S
C -J
V
A P
O O
L E
M
A R
C H
F
IN
A L D
E S
IG
N
S U
B M
IT
T
A L
SCALE = 3/32" = 1'-0"C2
LIFE SAFETY PLAN - THIRD FLOOR - COMPREHENSIVE
16'8' 32'0
SCALE: 3/32" = 1'-0"
DEC: DEAD-END CORRIDOR
MTD: MAXIMUM TRAVEL DISTANCE
CPT: COMMON PATH OF TRAVEL
TAG ABBREVIATIONS:
EGRESS PATH SCHEDULE-FIRST
FLOOR
TAG
ACTUAL
LENGTH OCCUPANCY
MAXIMUM
ALLOWABLE
LENGTH
CPT1.1 50' - 6" S 50' - 0"
CPT3.1 37' - 0" R 35' - 0"
MTD1.1 24' - 6" R 75' - 0"
MTD1.2 74' - 3" R 100' - 0"
MTD2.1 71' - 9" R 100' - 0"
MTD2.2 23' - 8" R 75' - 0"
45 ft² 1
R200 ft²
BATHROOM
111-12A
BATHROOM
111-12A
44 ft² 1
R200 ft²
BATHROOM
105-6A
BATHROOM
105-6A
44 ft² 1
R200 ft²
BATHROOM
113-14A
BATHROOM
113-14A
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
230 ft² 2
R200 ft²
BEDROOM
BEDROOM
230 ft² 2
R200 ft²
BEDROOM
BEDROOM
225 ft² 2
R200 ft²
BEDROOM
BEDROOM
225 ft² 2
R200 ft²
BEDROOM
BEDROOM
201 ft² 2
R200 ft²
BEDROOM
BEDROOM
91 ft² 1
S500 ft²
STORAGE
STORAGE
208 ft² 2
R200 ft²
BEDROOM
BEDROOM
41 ft² 1
R200 ft²
BATHROOM
104A
BATHROOM
104A
223 ft² 2
R200 ft²
BEDROOM
BEDROOM
44 ft² 1
R200 ft²
BATHROOM
107-8A
BATHROOM
107-8A
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
227 ft² 2
R200 ft²
BEDROOM
BEDROOM
227 ft² 2
R200 ft²
BEDROOM
BEDROOM
221 ft² 2
R200 ft²
BEDROOM
BEDROOM
44 ft² 1
R200 ft²
BATHROOM
109-10A
BATHROOM
109-10A
137 ft² 1
B150 ft²
ENTRANCE
CORRIDOR
C001
ENTRANCE
CORRIDOR
C001
D
D 68
C
G
-1
C
G -1
D
1155 ft² 6
R200 ft²
CORRIDOR
CORRIDOR
27 ft² 1
S500 ft²
JC
JC
41 ft² 1
S500 ft²
RESTROOM
RESTROOM
SYMBOL DESCRIPTION
OCCUPANCY TAG
A: AREA (ft²)
B: OCCUPANT LOAD FACTOR
C: OCCUPANT LOAD
D: OCCUPANCY USE
LIFE SAFETY LEGEND
ACTUAL CLEAR WIDTH
EGRESS COMPONENT:
(D)DOOR (S)STAIRWAY
REQUIRED CLEAR WIDTH
ACTUAL EGRESS
MAXIMUM EGRESS CAPACITY
EGRESS CAPACITY TAG
D
A
B
C
D
OCCUPANCY USE LEGEND
DESCRIPTIONHATCH USE
ASSEMBLY - LESS CONCENTRATED
15ft²/PERSON, NET
A
B
STORAGE
500ft²/PERSON, GROSS
S
MECH, ELEC, OTHER BUILDING EQUIP
SPACES 500ft²/PERSON, GROSS
M
BUSINESS
150ft²/PERSON, GROSS
RESIDENTIAL
200ft²/PERSON, GROSS
R
IT EQUIPMENT ROOMS
300ft²/PERSON, GROSS
IT
A B
PLAN NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
F A
-2
-D
P T
F L
-1
KEYPLAN
GRAPHIC SCALE NORTH ARROW
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-F
.r v t
/2
/2
:2
:0
P
M
G-104
L
IF
E S
A F
E T
Y O
C C
U P
A N
T L
O A
D P
L A
N
F
IR
S T
F L O
O R
A
R E
A A
K B
O Y
E R
A S
T E
IN
W
A C
H S
B S
C -J
V
A P
O O
L E
M
A R
C H
F
IN
A L D
E S
IG
N
S U
B M
IT
T
A L
SCALE = 1/8" = 1'-0"C2
LIFE SAFETY OCCUPANT LOAD PLAN - FIRST FLOOR - AREA A
8'4' 16'0
SCALE: 1/8"=1'-0"
44 ft² 1
BATHROOM
123-24A
BATHROOM
123-24A
44 ft² 1
R200 ft²
BATHROOM
125-26A
BATHROOM
125-26A
44 ft² 1
R200 ft²
BATHROOM
121-22A
BATHROOM
121-22A
44 ft² 1
R200 ft²
BATHROOM
128-27A
BATHROOM
128-27A
39 ft² 1
R200 ft²
BATHROOM
118A
BATHROOM
118A
229 ft² 2
R200 ft²
BEDROOM
BEDROOM
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
227 ft² 2
R200 ft²
BEDROOM
BEDROOM
221 ft² 2
R200 ft²
BEDROOM
BEDROOM
230 ft² 2
R200 ft²
BEDROOM
BEDROOM
223 ft² 2
R200 ft²
BEDROOM
BEDROOM
227 ft² 2
R200 ft²
BEDROOM
BEDROOM
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
1155 ft² 6
R200 ft²
CORRIDOR
CORRIDOR
537 ft² 2
S500 ft²
STORAGE
101A
STORAGE
101A
74 ft² 1
S500 ft²
STORAGE
101B
STORAGE
101B
59 ft² 1
S500 ft²
CL
CL
53 ft² 1
S500 ft²
CL
CL
319 ft² 1
M500 ft²
MECH
ROOM
120N
MECH
ROOM
120N
67 ft² 1
IT300 ft²
TELECOM
115N
TELECOM
115N
165 ft² 1
M500 ft²
ELEC
ROOM
119N
ELEC
ROOM
119N
C
G
-1
C
G -1
C
G
-1
D 34
SYMBOL DESCRIPTION
OCCUPANCY TAG
A: AREA (ft²)
B: OCCUPANT LOAD FACTOR
C: OCCUPANT LOAD
D: OCCUPANCY USE
LIFE SAFETY LEGEND
ACTUAL CLEAR WIDTH
EGRESS COMPONENT:
(D)DOOR (S)STAIRWAY
REQUIRED CLEAR WIDTH
ACTUAL EGRESS
MAXIMUM EGRESS CAPACITY
EGRESS CAPACITY TAG
D
A
B
C
D
OCCUPANCY USE LEGEND
DESCRIPTIONHATCH USE
ASSEMBLY - LESS CONCENTRATED
15ft²/PERSON, NET
A
B
STORAGE
500ft²/PERSON, GROSS
S
MECH, ELEC, OTHER BUILDING EQUIP
SPACES 500ft²/PERSON, GROSS
M
BUSINESS
150ft²/PERSON, GROSS
RESIDENTIAL
200ft²/PERSON, GROSS
R
IT EQUIPMENT ROOMS
300ft²/PERSON, GROSS
IT
A B
PLAN NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
F A
-2
-D
P T
F L
-1
KEYPLAN
GRAPHIC SCALE NORTH ARROW
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-F
.r v t
/2
/2
:2
:0
P
M
G-105
L
IF
E S
A F
E T
Y O
C C
U P
A N
T L
O A
D P
L A
N
F
IR
S T
F L O
O R
A
R E
A B
K B
O Y
E R
A S
T E
IN
W
A C
H S
B S
C -J
V
A P
O O
L E
M
A R
C H
F
IN
A L D
E S
IG
N
S U
B M
IT
T
A L
8'4' 16'0
SCALE: 1/8"=1'-0"
SCALE = 1/8" = 1'-0"C2
LIFE SAFETY OCCUPANT LOAD PLAN - FIRST FLOOR - AREA B
SYMBOL DESCRIPTION
OCCUPANCY TAG
A: AREA (ft²)
B: OCCUPANT LOAD FACTOR
C: OCCUPANT LOAD
D: OCCUPANCY USE
LIFE SAFETY LEGEND
ACTUAL CLEAR WIDTH
EGRESS COMPONENT:
(D)DOOR (S)STAIRWAY
REQUIRED CLEAR WIDTH
ACTUAL EGRESS
MAXIMUM EGRESS CAPACITY
EGRESS CAPACITY TAG
D
A
B
C
D
OCCUPANCY USE LEGEND
DESCRIPTIONHATCH USE
ASSEMBLY - LESS CONCENTRATED
15ft²/PERSON, NET
A
B
STORAGE
500ft²/PERSON, GROSS
S
MECH, ELEC, OTHER BUILDING EQUIP
SPACES 500ft²/PERSON, GROSS
M
BUSINESS
150ft²/PERSON, GROSS
RESIDENTIAL
200ft²/PERSON, GROSS
R
IT EQUIPMENT ROOMS
300ft²/PERSON, GROSS
IT
907 ft² 7
B150 ft²
123 ft² 1
B150 ft²
104 ft² 1
B150 ft²
71 ft² 1
B150 ft²
A B
PLAN NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
F A
-2
-D
P T
F L
-1
KEYPLAN
GRAPHIC SCALE NORTH ARROW
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-F
.r v t
/2
/2
:2
:0
P
M
G-106
L
IF
E S
A F
E T
Y O
C C
U P
A N
T L
O A
D P
L A
N
F
IR
S T
F L O
O R
L A
U N
D R
Y
K B
O Y
E R
A S
T E
IN
W
A C
H S
B S
C -J
V
A P
O O
L E
M
A R
C H
F
IN
A L D
E S
IG
N
S U
B M
IT
T
A L
8'4' 16'0
SCALE: 1/8"=1'-0"
LIFE SAFETY OCCUPANT LOAD PLAN - FIRST FLOOR - LAUNDRY
BATHROOM
209-10A
BATHROOM
209-10A
44 ft² 1
R200 ft²
BATHROOM
207-08A
BATHROOM
207-08A
44 ft² 1
R200 ft²
BATHROOM
205-6A
BATHROOM
205-6A
44 ft² 1
R200 ft²
BATHROOM
213-14A
BATHROOM
213-14A
13 ft² 1
R200 ft²
JC
JC
147 ft² 1
S500 ft²
STORAGE
STORAGE
154 ft² 2
B150 ft²
STAIR A
ST-A
STAIR A
ST-A230 ft² 2
R200 ft²
BEDROOM
BEDROOM
225 ft² 2
R200 ft²
BEDROOM
BEDROOM
1063 ft² 6
R200 ft²
CORRIDOR
CORRIDOR
205 ft² 2
R200 ft²
BEDROOM
BEDROOM
223 ft² 2
R200 ft²
BEDROOM
BEDROOM
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
208 ft² 2
R200 ft²
BEDROOM
BEDROOM
41 ft² 1
R200 ft²
BATHROOM
204A
BATHROOM
204A
223 ft² 2
R200 ft²
BEDROOM
BEDROOM
229 ft² 2
R200 ft²
BEDROOM
BEDROOM
227 ft² 2
R200 ft²
BEDROOM
BEDROOM
228 ft² 2
R200 ft²
BEDROOM
BEDROOM
224 ft² 2
R200 ft²
BEDROOM
BEDROOM
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
44 ft² 1
R200 ft²
BATHROOM
211-12A
BATHROOM
211-12A
S
D
S
C
G
-1
C
G -1
D
SYMBOL DESCRIPTION
OCCUPANCY TAG
A: AREA (ft²)
B: OCCUPANT LOAD FACTOR
C: OCCUPANT LOAD
D: OCCUPANCY USE
LIFE SAFETY LEGEND
ACTUAL CLEAR WIDTH
EGRESS COMPONENT:
(D)DOOR (S)STAIRWAY
REQUIRED CLEAR WIDTH
ACTUAL EGRESS
MAXIMUM EGRESS CAPACITY
EGRESS CAPACITY TAG
D
A
B
C
D
OCCUPANCY USE LEGEND
DESCRIPTIONHATCH USE
ASSEMBLY - LESS CONCENTRATED
15ft²/PERSON, NET
A
B
STORAGE
500ft²/PERSON, GROSS
S
MECH, ELEC, OTHER BUILDING EQUIP
SPACES 500ft²/PERSON, GROSS
M
BUSINESS
150ft²/PERSON, GROSS
RESIDENTIAL
200ft²/PERSON, GROSS
R
IT EQUIPMENT ROOMS
300ft²/PERSON, GROSS
IT
A B
PLAN NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
F A
-2
-D
P T
F L
-1
KEYPLAN
GRAPHIC SCALE NORTH ARROW
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-F
.r v t
/2
/2
:2
:0
P
M
G-107
L
IF
E S
A F
E T
Y O
C C
U P
A N
T L
O A
D P
L A
N
S E
C O
N D
F L O
O R
A
R E
A A
K B
O Y
E R
A S
T E
IN
W
A C
H S
B S
C -J
V
A P
O O
L E
M
A R
C H
F
IN
A L D
E S
IG
N
S U
B M
IT
T
A L
8'4' 16'0
SCALE: 1/8"=1'-0"
LIFE SAFETY OCCUPANT LOAD PLAN - SECOND FLOOR - AREA A
49 ft² 1
BATHROOM
223-24A
BATHROOM
223-24A
49 ft² 1
R200 ft²
BATHROOM
226-25A
BATHROOM
226-25A
44 ft² 1
R200 ft²
BATHROOM
221-22A
BATHROOM
221-22A
44 ft² 1
R200 ft²
BATHROOM
228-27A
BATHROOM
228-27A
236 ft² 2
R200 ft²
DAY
ROOM
DAY
ROOM
231 225 ft² 2
R200 ft²
BEDROOM
BEDROOM
100 ft² 1
S500 ft²
CL
CL
34 ft² 1
M500 ft²
ELEC
219N
ELEC
219N
67 ft² 1
IT300 ft²
TELECOM
215N
TELECOM
215N
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
224 ft² 2
R200 ft²
BEDROOM
BEDROOM
229 ft² 2
R200 ft²
BEDROOM
BEDROOM
223 ft² 2
R200 ft²
BEDROOM
BEDROOM
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
230 ft² 2
R200 ft²
BEDROOM
BEDROOM
223 ft² 2
R200 ft²
BEDROOM
BEDROOM
313 ft² 2
R200 ft²
LOUNGE /
CAFE
AREA
LOUNGE /
CAFE
AREA
143 ft² 1
S500 ft²
STORAGE
217N
STORAGE
217N
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
44 ft² 1
R200 ft²
BATHROOM
220A
BATHROOM
220A
S
C
G
-1
C
G -1
D 34
87 ft² 1
S500 ft²
CL
CL
SYMBOL DESCRIPTION
OCCUPANCY TAG
A: AREA (ft²)
B: OCCUPANT LOAD FACTOR
C: OCCUPANT LOAD
D: OCCUPANCY USE
LIFE SAFETY LEGEND
ACTUAL CLEAR WIDTH
EGRESS COMPONENT:
(D)DOOR (S)STAIRWAY
REQUIRED CLEAR WIDTH
ACTUAL EGRESS
MAXIMUM EGRESS CAPACITY
EGRESS CAPACITY TAG
D
A
B
C
D
OCCUPANCY USE LEGEND
DESCRIPTIONHATCH USE
ASSEMBLY - LESS CONCENTRATED
15ft²/PERSON, NET
A
B
STORAGE
500ft²/PERSON, GROSS
S
MECH, ELEC, OTHER BUILDING EQUIP
SPACES 500ft²/PERSON, GROSS
M
BUSINESS
150ft²/PERSON, GROSS
RESIDENTIAL
200ft²/PERSON, GROSS
R
IT EQUIPMENT ROOMS
300ft²/PERSON, GROSS
IT
A B
PLAN NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
F A
-2
-D
P T
F L
-1
KEYPLAN
GRAPHIC SCALE NORTH ARROW
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-F
.r v t
/2
/2
:2
:0
P
M
G-108
L
IF
E S
A F
E T
Y O
C C
U P
A N
T L
O A
D P
L A
N
S E
C O
N D
F L O
O R
A
R E
A B
K B
O Y
E R
A S
T E
IN
W
A C
H S
B S
C -J
V
A P
O O
L E
M
A R
C H
F
IN
A L D
E S
IG
N
S U
B M
IT
T
A L
SCALE = 1/8" = 1'-0"C2
LIFE SAFETY OCCUPANT LOAD PLAN - SECOND FLOOR - AREA B
BATHROOM
309-10A
BATHROOM
309-10A
44 ft² 1
R200 ft²
BATHROOM
308-07A
BATHROOM
308-07A
44 ft² 1
R200 ft²
BATHROOM
311-12A
BATHROOM
311-12A
44 ft² 1
R200 ft²
BATHROOM
305-6A
BATHROOM
305-6A
44 ft² 1
R200 ft²
BATHROOM
313-14A
BATHROOM
313-14A
154 ft² 2
B150 ft²
STAIR A
ST-A
STAIR A
ST-A
13 ft² 1
S500 ft²
JC
JC
160 ft² 1
S500 ft²
STORAGE
STORAGE
1078 ft² 6
R200 ft²
CORRIDOR
CORRIDOR
225 ft² 2
R200 ft²
BEDROOM
BEDROOM
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
205 ft² 2
R200 ft²
BEDROOM
BEDROOM
41 ft² 1
R200 ft²
BATHROOM
304A
BATHROOM
304A
208 ft² 2
R200 ft²
BEDROOM
BEDROOM
223 ft² 2
R200 ft²
BEDROOM
BEDROOM
229 ft² 2
R200 ft²
BEDROOM
BEDROOM
224 ft² 2
R200 ft²
BEDROOM
BEDROOM
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
227 ft² 2
R200 ft²
BEDROOM
BEDROOM
228 ft² 2
R200 ft²
BEDROOM
BEDROOM
223 ft² 2
R200 ft²
BEDROOM
BEDROOM
230 ft² 2
R200 ft²
BEDROOM
BEDROOM
S
S
D
C
G
-1
C
G -1
D
SYMBOL DESCRIPTION
OCCUPANCY TAG
A: AREA (ft²)
B: OCCUPANT LOAD FACTOR
C: OCCUPANT LOAD
D: OCCUPANCY USE
LIFE SAFETY LEGEND
ACTUAL CLEAR WIDTH
EGRESS COMPONENT:
(D)DOOR (S)STAIRWAY
REQUIRED CLEAR WIDTH
ACTUAL EGRESS
MAXIMUM EGRESS CAPACITY
EGRESS CAPACITY TAG
D
A
B
C
D
OCCUPANCY USE LEGEND
DESCRIPTIONHATCH USE
ASSEMBLY - LESS CONCENTRATED
15ft²/PERSON, NET
A
B
STORAGE
500ft²/PERSON, GROSS
S
MECH, ELEC, OTHER BUILDING EQUIP
SPACES 500ft²/PERSON, GROSS
M
BUSINESS
150ft²/PERSON, GROSS
RESIDENTIAL
200ft²/PERSON, GROSS
R
IT EQUIPMENT ROOMS
300ft²/PERSON, GROSS
IT
A B
PLAN NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
F A
-2
-D
P T
F L
-1
KEYPLAN
GRAPHIC SCALE NORTH ARROW
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-F
.r v t
/2
/2
:2
:1
P
M
G-109
L
IF
E S
A F
E T
Y O
C C
U P
A N
T L
O A
D P
L A
N
T H
IR
D
F L O
O R
A
R E
A A
K B
O Y
E R
A S
T E
IN
W
A C
H S
B S
C -J
V
A P
O O
L E
M
A R
C H
F
IN
A L D
E S
IG
N
S U
B M
IT
T
A L
SCALE = 1/8" = 1'-0"C2
LIFE SAFETY OCCUPANT LOAD PLAN - THIRD FLOOR - AREA A
43 ft² 1
BATHROOM
323-24A
BATHROOM
323-24A
43 ft² 1
R200 ft²
BATHROOM
326-25A
BATHROOM
326-25A
44 ft² 1
R200 ft²
BATHROOM
321-22A
BATHROOM
321-22A
44 ft² 1
R200 ft²
BATHROOM
328-27A
BATHROOM
328-27A
43 ft² 1
R200 ft²
BATHROOM
320A
BATHROOM
320A
528 ft² 36
A15 ft²
LOUNGE /
CAFE
AREA
LOUNGE /
CAFE
AREA
102 ft² 1
S500 ft²
CL
CL
34 ft² 1
M500 ft²
ELEC
319N
ELEC
319N
67 ft² 1
IT300 ft²
TELECOM
315N
TELECOM
315N
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
224 ft² 2
R200 ft²
BEDROOM
BEDROOM
229 ft² 2
R200 ft²
BEDROOM
BEDROOM
223 ft² 2
R200 ft²
BEDROOM
BEDROOM
222 ft² 2
R200 ft²
BEDROOM
BEDROOM
225 ft² 2
R200 ft²
BEDROOM
BEDROOM
230 ft² 2
R200 ft²
BEDROOM
BEDROOM
223 ft² 2
R200 ft²
BEDROOM
BEDROOM
143 ft² 1
S500 ft²
STORAGE
317N
STORAGE
317N
S
C
G
-1
C
G -1
D 34
96 ft² 1
S500 ft²
CL
330A
CL
330A
SYMBOL DESCRIPTION
OCCUPANCY TAG
A: AREA (ft²)
B: OCCUPANT LOAD FACTOR
C: OCCUPANT LOAD
D: OCCUPANCY USE
LIFE SAFETY LEGEND
ACTUAL CLEAR WIDTH
EGRESS COMPONENT:
(D)DOOR (S)STAIRWAY
REQUIRED CLEAR WIDTH
ACTUAL EGRESS
MAXIMUM EGRESS CAPACITY
EGRESS CAPACITY TAG
D
A
B
C
D
OCCUPANCY USE LEGEND
DESCRIPTIONHATCH USE
ASSEMBLY - LESS CONCENTRATED
15ft²/PERSON, NET
A
B
STORAGE
500ft²/PERSON, GROSS
S
MECH, ELEC, OTHER BUILDING EQUIP
SPACES 500ft²/PERSON, GROSS
M
BUSINESS
150ft²/PERSON, GROSS
RESIDENTIAL
200ft²/PERSON, GROSS
R
IT EQUIPMENT ROOMS
300ft²/PERSON, GROSS
IT
A B
PLAN NORTH
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
M C
G U
IR
E
A F
B L A
K E
H U
R S
T N
E W
J E
R S
E Y
M C
G U
IR
E
A F
B
N E
W J
E R
S E
Y R
E N
O V
A T
IO
N
O F
D O
R M
IT
O
R Y
B U
IL
D
IN
G
F A
-2
-D
P T
F L
-1
KEYPLAN
GRAPHIC SCALE NORTH ARROW
U S
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
A u to d e s k D o c s
/1 J
B M
D L D o rm
R e n o
B -B
/P
T F
L -B
-F
.r v t
/2
/2
:2
:1
P
M
G-110
L
IF
E S
A F
E T
Y O
C C
U P
A N
T L
O A
D P
L A
N
T H
IR
D
F L O
O R
A
R E
A B
K B
O Y
E R
A S
T E
IN
W
A C
H S
B S
C -J
V
A P
O O
L E
M
A R
C H
F
IN
A L D
E S
IG
N
S U
B M
IT
T
A L
SCALE = 1/8" = 1'-0"C2
LIFE SAFETY OCCUPANT LOAD PLAN - THIRD FLOOR - AREA B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
SHEET ID
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
S.
S
H O
AF
C . P
R O
FF
IT
T
C . A
R N
O
LD
BS
C
-J V
C
IV
IL
N
O
TE
S
C-001
M C
G U
IR
E
AI
R
F O
R C
E
BA
SE
M
C G
U
IR
E
AF
B
LA
KE
H
U R
ST
, N
J
FA
-2
1- D
M
AR
C
H
AN
SI
D
PT
FL
2-
M C
G U
IR
E
AF
B, N
EW
J
ER
SE
Y
R
EN
O
VA
TI
O
N O
F D
O M
IR
TO
R Y
BU
IL
D
IN
G
0%
F
IN
AL
D
ES
IG
N S
U
BM
IT
TA
L C
:\U
SE
R S\
C H
R
IS
TO
PH
ER
.P
R O
FF
IT
T\ D
C \A
C C
D O
C S\
M
IC
H
AE
L
BA
KE
R
IN
TE
R N
AT
IO
N
AL
\1
JB
M
D L
D O
R M
R
EN
O
B2
9- B2
1\
PR
O
JE
C
T
FI
LE
S\
. C
IV
IL
-S
IT
E\
\S
H
EE
TS
\C
-0
.D W
G
AE
C _N
C S_
4_ M
O N
O .C
TB
C
H R
IS
TO
PH
ER
.P R
O
FF
IT
T
GENERAL PROJECT NOTES
1. ALL CONSTRUCTION MATERIALS AND/OR EQUIPMENT NOT REUSED OR
DESIGNATED AS SALVAGE MATERIAL BY THE CONTRACTING OFFICER IN
THIS PROJECT SHALL BECOME PROPERTY OF THE CONTRACTOR, AND IT
SHALL BE THE CONTRACTOR RESPONSIBILITY FOR LAWFUL DISPOSAL OR
RECYCLING OFF GOVERNMENT PROPERTY.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY
PERMITS AND FOR NOTIFICATION OF ALL AUTHORIZED INSPECTORS,
SUPERINTENDENTS OR PERSONS IN CHARGE OF PRIVATE OR PUBLIC
UTILITIES AFFECTED BY CONTRACT OPERATIONS PRIOR TO
COMMENCEMENT OF WORK.
3. CONTRACTOR SHALL COORDINATE THE RELOCATION AND SALVAGE OF ANY
GOVERNMENT OWNED EQUIPMENT WITH THE CONTRACTING OFFICER.
4. ALL CONTRACTOR EMPLOYEES SHALL CARRY CONTRACTOR PHOTO
IDENTIFICATION AT ALL TIMES WHILE WORKING INSIDE THE BASE SECURE
PERIMETER.
5. CONTRACTOR EMPLOYEES SHALL COMPLY WITH ANY INTEGRATED
DEFENSE MEASURES THAT MAY BE NECESSARY DURING CONTINGENCY
OPERATIONS. THIS INCLUDES, BUT IS NOT LIMITED TO, VEHICLE
INSPECTIONS, IDENTIFICATION CHECKS, ETC.
6. ALL CONTRACTOR VEHICLES ARE SUBJECT TO SEARCH PRIOR TO
ENTERING THE BASE. VEHICLES MUST CARRY CURRENT REGISTRATION
AND PROOF OF INSURANCE.
7. ALL DIMENSIONS, ELEVATIONS, AND STATIONS ARE IN FEET UNLESS
INDICATED.
8. ALL PIPE SIZES ARE IN INCHES UNLESS INDICATED OTHERWISE.
9. ANY SOILS BROUGHT ON-SITE FROM OFF-BASE AND USED FOR BACKFILL
MUST BE PROPERLY TESTED OR CERTIFIED CLEAN (WITH APPROPRIATE
DOCUMENTATION) TO ENSURE THAT NO CONTAMINANTS ARE BEING
APPLIED ON-SITE.
ACCESS AND SAFETY NOTES
1. ACCESS TO THE PROJECT FOR ALL CONTRACTOR PERSONNEL, VEHICLES,
AND EQUIPMENT IS ILLUSTRATED ON C-003. ACCESS TO THE SITE SHALL BE
THROUGH THE COMMERCIAL GATE. ACCESS ROUTES MAY BE SUBJECT TO
CHANGE BASED ON OPERATIONAL REQUIREMENTS ON BASE.
2. THE EXISTING BASE ROAD SPEED LIMITS AND LOAD LIMITS ARE STRICTLY
ENFORCED. ALL CONCRETE TRUCKS SHALL PUT DOWN EXTRA AXLES
WHEN TRAVELING ON GOVERNMENT PROPERTY.
3. A WELDING PERMIT IS REQUIRED PRIOR TO PERFORMING ANY WELDING OR
CUTTING OPERATIONS. THE PERMIT CAN BE OBTAINED AT THE BASE FIRE
DEPARTMENT INSPECTOR .
EXISTING CONDITION NOTES
1. THE CONTRACTOR SHALL CONDUCT A SUBSURFACE UTILITY ENGINEERING
(SUE) QUALITY LEVEL "A" SURVEY OF THE ENTIRE SITE TO VERIFY ALL
EXISTING CONDITIONS AND BE THOROUGHLY FAMILIAR WITH THE SITE
BEFORE ANY WORK COMMENCES. ANY DISCREPANCIES IN THE DRAWINGS
SHALL BE IMMEDIATELY REPORTED TO THE COR BEFORE ANY FURTHER
WORK COMMENCES.
2. THE LOCATIONS OF STRUCTURES AND UNDERGROUND UTILITIES AS
INDICATED HAVE BEEN OBTAINED FROM EXISTING RECORDS AND FIELD
SURVEYS. UNDERGROUND STRUCTURES AND UTILITIES MAY BE PRESENT
WHICH ARE NOT DOCUMENTED OR LOCATED.
3. A SURVEY OF THE SITE WAS PERFORMED BY MIDLAND SURVEYING AND
MAPPING JV LLC DURING AUGUST AND SEPTEMBER 2023.
4. ELEVATION DATA IS REFERENCED TO NAVD88, GEOID18 BASED UPON 2+
HOUR OPUS OBSERVATIONS COMPLETED ON PROJECT CONTROL
MONUMENTS.
5. HORIZONTAL COORDINATES ARE REFERENCED TO NEW JERSEY STATE
PLANE COORDINATES, 1983 NAD. COORDINATES WERE ESTABLISHED
BASED UPON 2+ HOUR OPUS OBSERVATIONS COMPLETED ON PROJECT
CONTROL MONUMENTS.
EXCAVATION AND TRENCHES
1. CONTRACTOR SHALL COMPLY WITH THE MOST CURRENT EDITION OF OSHA
REGULATIONS, THE STATE OF NEW JERSEY LAWS CONCERNING
EXCAVATION, AND USACE EM 385-1-1 SAFETY AND HEALTH REQUIREMENT
MANUAL.
2. ALL WORK IN AND ADJACENT TO STREETS OR ROADS SHALL BE
COORDINATED WITH THE COR. THE CONTRACTOR SHALL PROVIDE THE COR
WITH A ONE-WEEK ADVANCE NOTICE PRIOR TO BEGINNING OF WORK
ADJACENT TO BASE ROADWAYS. NO WORK ADJACENT TO OR ON EXISTING
ROADS SHALL BE INITIATED WITHOUT PRIOR APPROVAL FROM THE
CONTRACTING OFFICER'S REPRESENTATIVE.
3. EXCAVATION FOR STRUCTURES AND TRENCHES SHALL BE PROPERLY AND
SUBSTANTIALLY SHEETED, BRACED, AND SHORED, AS REQUIRED AND IN
COMPLIANCE WITH ALL CURRENT OSHA REGULATIONS.
4. IN EVERY CASE WHERE TRENCHES HAVE BEEN EXCAVATED BELOW THE
SPECIFIED DEPTH FOR REQUIRED BEDDING, THE PIPE BEDDING SHALL
START AT THE BOTTOM OF SAID EXCAVATION.
5. ALL TRENCHES SHALL BE BACKFILLED IN UNIFORM LIFTS AND COMPACTED
IN ACCORDANCE WITH THE SPECIFICATIONS.
GENERAL DEMOLITION NOTES
1. CONTRACTOR SHALL COORDINATE LIMITS OF SAWCUT AND CONCRETE
REMOVAL WITH PROPOSED LAYOUT AND JOINTING PLAN. PAVEMENT
DESIGNATED FOR SAWCUT SHALL BE SAWCUT FULL DEPTH. EXISTING
CONCRETE EDGES SHALL BE SAWCUT TO PROVIDE CLEAN EDGE FOR
PROPOSED CONSTRUCTION.
2. CONCRETE REMOVAL LIMITS SHALL BE TO THE NEAREST EXISTING JOINT
TO THE GREATEST EXTENT POSSIBLE TO PREVENT PARTIAL PANEL
REMOVAL.
3. CONCRETE REMOVAL SHALL INCLUDE REMOVAL OF CONCRETE AND ANY
BASE AND SUBBASE MATERIAL PRESENT. CLEAN BASE AND SUBBASE MUST
BE USED AND PROPERLY COMPACTED WHERE CONCRETE IS BEING
REPLACED.
4. ALL ITEMS TO BE DEMOLISHED ARE SHOWN ON THE DRAWINGS TO INCLUDE
SIDEWALKS, STEPS, MECHANICAL YARD FENCE, SELECT UTILITIES, AND
ETC.
GENERAL UTILITY NOTES
1. AT LEAST 72 HOURS PRIOR TO BEGINNING ANY EXCAVATION (EXCLUDING
WEEKENDS AND HOLIDAYS), THE CONTRACTOR SHALL CONTACT THE
JBMDL/MCGUIRE AIR FORCE BASE ENGINEERING AND THE NEW JERSEY
ONE — CALL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .