J-4 - Internal Cryogenics - App C - Internal Cryogenics Interface Matrix.xlsx

XLSX spreadsheet 14 KB Posted

Attached to
LBNF Internal Cryogenics
Solicitation number
LBNF-357777-JD
Issued by

About this file

This document is an interface matrix for the internal cryogenics system of the LBNF (Long-Baseline Neutrino Facility) project. The matrix provides detailed technical specifications for thirty cryogenic transfer lines and their supports required to transfer liquid and gaseous argon within the DUNE (Deep Underground Neutrino Experiment) cryostats. Key details include the pipe type, fluid, operating conditions, physical interface, and insulation requirements for each transfer line. The matrix covers recirculation, cool-down, emergency return, and boil-off lines. This technical information supports the LBNF-357777-JD solicitation for the engineering, manufacturing, and delivery of the internal cryogenics piping systems for the first two LBNF cryostats located at the Sanford Underground Research Facility in Lead, South Dakota. The successful bidder will be responsible for providing these cryogenic transfer line systems to the project.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Interface Sheet

Interface TAGInterface PortPipe TypeTransfer Line NameFluidMaximum Allowable ParametersOperating ConditionsPhysical Interface
PressureTemperatureFlow ratePressureTemperatureFlow rateDNNPSSchType of InsulationCryostat Interface
bargpsigKkg/sbargpsigKkg/s
processLAr Recirculation 1.1 (vertical)LAr/GAr10145300401.72258720150610Vacuum-Jacketed (up to 0.55 m above cryostat floor)Conflat flange
vacuumvacuum1.522N/AN/Avacuum1vacuum1N/AN/A200810
processLAr Recirculation 1.1 manifold (horizontal)LAr/GAr10145300202.840871080310Uninsulated
processLAr Recirculation 1.2 (vertical)LAr10145300401.72258720150610Vacuum-Jacketed
vacuumvacuum1.522N/AN/Avacuum1vacuum1N/AN/A200810
processLAr Recirculation 1.2 manifold (horizontal)LAr10145300202.840871080310Uninsulated
processLAr Cool-Down 1.1-1.20 (each)LAr1014530021.722587125110Vacuum-Jacketed
vacuumvacuum1.522N/AN/Avacuum1vacuum1N/AN/A80310
processLAr Emergency Return 1LAr101453002.51.116871.2150610Vacuum-Jacketed
vacuumvacuum1.522N/AN/Avacuum1vacuum1N/AN/A200810
processGAr Boil-off 1.1-1.2GAr1014530011.116870.5150610Vacuum-Jacketed
vacuumvacuum1.522N/AN/Avacuum1vacuum1N/AN/A200810
processCryostat Pressure Relief 1.1-1.2GAr/GN21014530031.261887-30032501010Uninsulated
Interface TAGInterface PortPipe TypeTransfer Line NameFluidMaximum Allowable ParametersOperating ConditionsPhysical Interface
PressureTemperatureFlow ratePressureTemperatureFlow rateDNNPSSchType of InsulationCryostat Interface
bargpsigKkg/sbargpsigKkg/s
processLAr Recirculation 2.1 (vertical)LAr/GAr10145300401.72258720150610Vacuum-Jacketed (up to 0.55 m above cryostat floor)
vacuumvacuum1.522N/AN/Avacuum1vacuum1N/AN/A200810
processLAr Recirculation 2.1 manifold (horizontal)LAr/GAr10145300202.840871080310Uninsulated
processLAr Recirculation 2.2 (vertical)LAr10145300401.72258720150610Vacuum-Jacketed
vacuumvacuum1.522N/AN/Avacuum1vacuum1N/AN/A200810
processLAr Recirculation 2.2 manifold (horizontal)LAr10145300202.840871080310Uninsulated
processLAr Emergency Return 1LAr101453002.51.116871.2150610Vacuum-Jacketed
vacuumvacuum1.522N/AN/Avacuum1vacuum1N/AN/A200810
processGAr Boil-off 1.1-1.2GAr1014530011.116870.5150610Vacuum-Jacketed
vacuumvacuum1.522N/AN/Avacuum1vacuum1N/AN/A200810
processCryostat Pressure Relief 1.1-1.2GAr/GN21014530031.261887-30032501010Uninsulated

File details come from the government source that posted it. Updated .