J-4 - Internal Cryogenics - App C - Internal Cryogenics Interface Matrix.xlsx
XLSX spreadsheet 14 KB Posted
- Attached to
- LBNF Internal Cryogenics
- Solicitation number
- LBNF-357777-JD
About this file
This document is an interface matrix for the internal cryogenics system of the LBNF (Long-Baseline Neutrino Facility) project. The matrix provides detailed technical specifications for thirty cryogenic transfer lines and their supports required to transfer liquid and gaseous argon within the DUNE (Deep Underground Neutrino Experiment) cryostats. Key details include the pipe type, fluid, operating conditions, physical interface, and insulation requirements for each transfer line. The matrix covers recirculation, cool-down, emergency return, and boil-off lines. This technical information supports the LBNF-357777-JD solicitation for the engineering, manufacturing, and delivery of the internal cryogenics piping systems for the first two LBNF cryostats located at the Sanford Underground Research Facility in Lead, South Dakota. The successful bidder will be responsible for providing these cryogenic transfer line systems to the project.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Interface Sheet
| Interface TAG | Interface Port | Pipe Type | Transfer Line Name | Fluid | Maximum Allowable Parameters | Operating Conditions | Physical Interface | ||||||||||
| Pressure | Temperature | Flow rate | Pressure | Temperature | Flow rate | DN | NPS | Sch | Type of Insulation | Cryostat Interface | |||||||
| barg | psig | K | kg/s | barg | psig | K | kg/s | ||||||||||
| process | LAr Recirculation 1.1 (vertical) | LAr/GAr | 10 | 145 | 300 | 40 | 1.72 | 25 | 87 | 20 | 150 | 6 | 10 | Vacuum-Jacketed (up to 0.55 m above cryostat floor) | Conflat flange | ||
| vacuum | vacuum | 1.5 | 22 | N/A | N/A | vacuum1 | vacuum1 | N/A | N/A | 200 | 8 | 10 | |||||
| process | LAr Recirculation 1.1 manifold (horizontal) | LAr/GAr | 10 | 145 | 300 | 20 | 2.8 | 40 | 87 | 10 | 80 | 3 | 10 | Uninsulated | |||
| process | LAr Recirculation 1.2 (vertical) | LAr | 10 | 145 | 300 | 40 | 1.72 | 25 | 87 | 20 | 150 | 6 | 10 | Vacuum-Jacketed | |||
| vacuum | vacuum | 1.5 | 22 | N/A | N/A | vacuum1 | vacuum1 | N/A | N/A | 200 | 8 | 10 | |||||
| process | LAr Recirculation 1.2 manifold (horizontal) | LAr | 10 | 145 | 300 | 20 | 2.8 | 40 | 87 | 10 | 80 | 3 | 10 | Uninsulated | |||
| process | LAr Cool-Down 1.1-1.20 (each) | LAr | 10 | 145 | 300 | 2 | 1.72 | 25 | 87 | 1 | 25 | 1 | 10 | Vacuum-Jacketed | |||
| vacuum | vacuum | 1.5 | 22 | N/A | N/A | vacuum1 | vacuum1 | N/A | N/A | 80 | 3 | 10 | |||||
| process | LAr Emergency Return 1 | LAr | 10 | 145 | 300 | 2.5 | 1.1 | 16 | 87 | 1.2 | 150 | 6 | 10 | Vacuum-Jacketed | |||
| vacuum | vacuum | 1.5 | 22 | N/A | N/A | vacuum1 | vacuum1 | N/A | N/A | 200 | 8 | 10 | |||||
| process | GAr Boil-off 1.1-1.2 | GAr | 10 | 145 | 300 | 1 | 1.1 | 16 | 87 | 0.5 | 150 | 6 | 10 | Vacuum-Jacketed | |||
| vacuum | vacuum | 1.5 | 22 | N/A | N/A | vacuum1 | vacuum1 | N/A | N/A | 200 | 8 | 10 | |||||
| process | Cryostat Pressure Relief 1.1-1.2 | GAr/GN2 | 10 | 145 | 300 | 3 | 1.26 | 18 | 87-300 | 3 | 250 | 10 | 10 | Uninsulated | |||
| Interface TAG | Interface Port | Pipe Type | Transfer Line Name | Fluid | Maximum Allowable Parameters | Operating Conditions | Physical Interface | ||||||||||
| Pressure | Temperature | Flow rate | Pressure | Temperature | Flow rate | DN | NPS | Sch | Type of Insulation | Cryostat Interface | |||||||
| barg | psig | K | kg/s | barg | psig | K | kg/s | ||||||||||
| process | LAr Recirculation 2.1 (vertical) | LAr/GAr | 10 | 145 | 300 | 40 | 1.72 | 25 | 87 | 20 | 150 | 6 | 10 | Vacuum-Jacketed (up to 0.55 m above cryostat floor) | |||
| vacuum | vacuum | 1.5 | 22 | N/A | N/A | vacuum1 | vacuum1 | N/A | N/A | 200 | 8 | 10 | |||||
| process | LAr Recirculation 2.1 manifold (horizontal) | LAr/GAr | 10 | 145 | 300 | 20 | 2.8 | 40 | 87 | 10 | 80 | 3 | 10 | Uninsulated | |||
| process | LAr Recirculation 2.2 (vertical) | LAr | 10 | 145 | 300 | 40 | 1.72 | 25 | 87 | 20 | 150 | 6 | 10 | Vacuum-Jacketed | |||
| vacuum | vacuum | 1.5 | 22 | N/A | N/A | vacuum1 | vacuum1 | N/A | N/A | 200 | 8 | 10 | |||||
| process | LAr Recirculation 2.2 manifold (horizontal) | LAr | 10 | 145 | 300 | 20 | 2.8 | 40 | 87 | 10 | 80 | 3 | 10 | Uninsulated | |||
| process | LAr Emergency Return 1 | LAr | 10 | 145 | 300 | 2.5 | 1.1 | 16 | 87 | 1.2 | 150 | 6 | 10 | Vacuum-Jacketed | |||
| vacuum | vacuum | 1.5 | 22 | N/A | N/A | vacuum1 | vacuum1 | N/A | N/A | 200 | 8 | 10 | |||||
| process | GAr Boil-off 1.1-1.2 | GAr | 10 | 145 | 300 | 1 | 1.1 | 16 | 87 | 0.5 | 150 | 6 | 10 | Vacuum-Jacketed | |||
| vacuum | vacuum | 1.5 | 22 | N/A | N/A | vacuum1 | vacuum1 | N/A | N/A | 200 | 8 | 10 | |||||
| process | Cryostat Pressure Relief 1.1-1.2 | GAr/GN2 | 10 | 145 | 300 | 3 | 1.26 | 18 | 87-300 | 3 | 250 | 10 | 10 | Uninsulated |