J-1502000-14 Low-Sloped Roofs Inventory.pdf

PDF 748 KB Posted

Attached to
Facility Investment Services for Commercial Building Support
Solicitation number
N4008522R2625
Issued by

View the file

Other files

File Type Posted
J-0200000-09 ELINS_revised.xls XLS spreadsheet
J-1502000-09 Revised Elevator Inventory Rev2.xlsx XLSX spreadsheet
22R2625 Amendment 0003.pdf PDF
22R2625 Amendment 0002.pdf PDF
J-0200000-09 ELINS_revised.xls XLS spreadsheet
J-0200000 01 though 14 revised.pdf PDF
J-1502000-09 Revised Elevator Inventory.xlsx XLSX spreadsheet
J-1502000-23 Plymovent Exhaust System User Manual.pdf PDF
J-1502000 01 through 22 revised.pdf PDF
22R2625 Amendment 0001.pdf PDF
J-1502000-07 Boiler Tune-up.pdf PDF
0200000 J Commercial.doc DOC document
J-1502000-21 Dryer Exhaust Systems Floor Plans.pdf PDF
J-1502000-01 through 22.pdf PDF
J-1502000-17 Water Filters Inventory.xlsx XLSX spreadsheet
J-0200000-06 DigSafe Request.pdf PDF
J-0200000-08 Characteristic Meter Reading Info.xlsx XLSX spreadsheet
J-0200000-02 Wage Determination.txt TXT text file
J-1502000-09 Vertical Transportation Equipment (VTE).xlsx XLSX spreadsheet
J-0200000-09 ELINS Commercial.xls XLS spreadsheet
J-0200000-01 though 14.pdf PDF
J-1502000-11 OHD Inventory.xlsx XLSX spreadsheet
J-0200000-10 PNSY Contractor Crane.docx DOCX document
J-0200000-03 PNSY Station Regs.docx DOCX document
N4008522R2625- Solicitation.pdf PDF
J-1502000-15 Gutters and Roof Drains.xlsx XLSX spreadsheet
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

V

VV

V

V V

VV

PORTSMOUTH, N.H.NAVAL SHIPYARD

AE200

A1

AE201

C1

AE200

C1

AE201

A1

A

B

C

D

E

F

G

2 43 5 6 7

C2

AE301

B2

AE301

177' - 11"

7'

- 1 0"

1/2" / 1'-0"

1/2" / 1'-0"1/2" / 1'-0"

0"

0"

3"

0"

7"

0"

30' - 0" 30' - 0" 30' - 0" 27' - 11" 30' - 0" 30' - 0"

1/2" / 1'-0"

1/2" / 1'-0"

1/2" / 1'-0"

TYP

075200.A01

075200.A01

075200.A01

075200.A01

1.3

C.8

E.2

1/2" / 1'-0"

1/2" / 1'-0" 1/2" / 1'-0"

1/2" / 1'-0"

1/2" / 1'-0" 1/2" / 1'-0"

075200.C05 3

B4

AE311

B5

AE311

B3

AE311

1/2" / 1'-0"

A3

AE310

A2

AE310 A1

AE310

220070.C23

A1

AE310

A2

AE310

A3

AE310

075200.C05

TYP

A4

AE310

1/2" / 1'-0"

1 TYP

AE550

B3

TYP

220070.C21

220070.C23

TYP

TYP

055133.L04

1/2" / 1'-0"

1/2" / 1'-0"

2.3

D.5

TYP

075200.A01

IROLFF

A R C H I T E C

R E G I S T E R E D

AR0016072T

ST

A TE O

AD

T

IM

OTHY A. WI L L I A MS

0 10'

1/16" = 1'-0" GRAPHIC SCALE

20' 40' 60'

A

B

KEYPLAN

A

B

KEYPLAN

KEY NOTES 00

SHEET NOTES:

NOTES:

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

EPROJECT NO.:

DE

PA

RT

ME

NT

O

F

TH

E

NA

VY

P1

9 M

ED

IC

AL

/D

EN

TA

L C

LIN

IC

R

EP

LA

CE

ME

NT

NO

RT

H

IP

T

- N

OR

FO

LK

KI

TT

ER

Y, M

AI

NE

NA

VA

L S

TA

TI

ON

N

OR

FO

LK

NA

VA

L

FA

CI

LIT

IE

S

EN

GI

NE

ER

IN

G

CO

MM

AN

D

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

MA

ND

M

ID

-A

TL

AN

TI

C

P

OR

TS

MO

UT

H

NA

VA

L S

HI

PY

AR

D

FIRE PROTECTION

CHIEF ENGINEER

BRANCH MANAGER

DESIGN MANAGER

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

1391195

DRAWFORM REVISION: 10 OCTOBER 2014

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

JOANNE KRAUSE

SAM RUSSO

JAMES DONAHUE

6/14/2017

CONSTR. CONTR. NO.

N/A

C:

\U se rs\ eh b\D oc um en ts\

-B

LD

G-

5- A_ eh b.r vt 6/2

7/2

7 1 0:5

4:5 3 A

M

RO

OF

P

LA

N

AE103

JJD JRM/DMC JWW

12747345

PLAN

NORTH

SCALE: 1/16" = 1'-0"

ROOF PLAN

MATERIAL NOTES

055133.L04 ALUMINUM SHIP'S LADDER

075200.A01 MODIFIED BITUMEN ROOFING SYSTEM

075200.C05 ROOF WALKWAY PAD

220070.C21 PRIMARY ROOF DRAIN

220070.C23 OVERFLOW ROOF DRAIN

A REFER TO SHEETS GI004 FOR GENERAL

ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.

B R-VALUE FOR ALL ROOF INSULATION IS TO BE

EQUAL TO R-30.

C ARROWS INDICATE ROOF SLOPE. ALL SLOPES TO

BE AS INDICATED ON PLAN.

D PROVIDE ROOF CRICKETS AT THE HIGH SIDE OF

ALL EQUIPMENT CURBS TO DIVERT WATER ON THE

ROOF.

E REFER TO SHEET AE550 FOR TYPICAL ROOF

DETAILS.

1 ROOF CRICKET, TYP.

2 SECOND LEVEL ROOF. REFERENCE SHEET AE102B.

3 ROOF RIDGE LINE.

4 OPTION #1, REFER TO SHEET AE701

5 STAINLESS STEEL CABLE

402-17-099 rdb Area Measurement 26,717.8 sf rdb Area Measurement

435.72 sf

File details come from the government source that posted it. Updated .