17260.pdf

PDF 59 KB Posted

Attached to
MDC Guaynabo - Upgrade Control Center Federal contract opportunity
Solicitation number
IFBP0306JPZ50004
Issued by
Department of Justice Bureau of Prisons Southeast Regional Office

About this file

Technical Design Guideline 17260

View the file

Other files for this federal contract opportunity

Other files attached to MDC Guaynabo - Upgrade Control Center, newest first.
File Type Posted
Bid Results.pdf PDF
Amendment 5.pdf PDF
Amendment 4.pdf PDF
Final Questions and Answers.pdf PDF
17100.pdf PDF
17200.pdf PDF
Amendment 3.pdf PDF
17180.pdf PDF
17020.pdf PDF
17050.pdf PDF
17040.pdf PDF
scan0020.pdf PDF
MDC Guaynabo - Upgrade Control Center Site Visit Meeting Minutes.pdf PDF
17300.pdf PDF
17220.pdf PDF
Amendment 1.pdf PDF
17165.pdf PDF
17120.pdf PDF
17900.pdf PDF
C - Attachment 1 —
E - Attachment 3 —
F - Attachment 4 —
A - Cover Letter.pdf PDF
B - Solicitation.pdf PDF
D - Attachment 2 —
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FBOP TECHNICAL DESIGN GUIDELINES ISSUE DATE: DECEMBER 10, 2004

SENSITIVE - LOU

GENERAL PAGING SYSTEM 17260-1

SECTION 17260 - GENERAL PAGING SYSTEM

PART 1 - GENERAL

1.1

SUMMARY

A.

This section covers all general paging system as shown on the drawings or as required to support the systems defined in these specifications. The work under this section consists of furnishing materials and equipment, performing labor and services necessary for the installation of the general paging system required for the security electronics, communications, and fire alarm system.

B.

Related Work Specified Elsewhere: Refer to all other Division 17 specification sections and drawings, and to the specifications and drawings under the General Construction

Contract to ascertain the extent of work included.

1.2

SUBMITTALS

A.

Since the Division 17 systems must be reviewed by the Contracting Officer as a system, no individual, specific submittal shall be made for this section. Submittals shall be packaged in groups and shall be made in accordance with the General Provisions (Section 17000) of these specifications.

1.3

REFERENCES AND CODES:

A.

National Electrical Code

1.4

SYSTEM DESCRIPTION:

A.

Paging system shall provide the capability to page the entire facility as one zone. Access to the paging system shall be via the Central Control panel intercom & paging microphones connected to the paging amplifiers by the PLC system and audio switching relays for intercom and paging as shown on the drawings.

B.

Access to the camp public address system is via a desk-top microphone with base push button in the Camp Message Center. Central Control shall not have access to the paging system in the camp. (FCI, USP only)

C.

Access to the UNICOR factory public address speakers is via a desk-top microphone with base push button in the UNICOR office area as shown on the plans. To prevent feedback a feedback destroyer shall be employed. Central Control shall also have access the UNICOR factory public address speakers on the facility all call paging function.

Access from Central Control shall have priority over the access from the UNICOR office area microphone. (FCI, USP only)

GENERAL PAGING SYSTEM 17260-2

D.

Access to the Commissary and Camp Commissary public address speakers is via a desk-top microphone with base push button, as shown on the plans. To prevent feedback, a feedback destroyer shall be employed. The microphone shall only address the dedicated speaks, as shown on the plans. Central Control shall also have access the public address speakers on the facility all call paging function. Access from Central Control shall have priority over the dedicated speakers in the event that both locations attempt to simultaneously broadcast. (FCI, USP only)

E.

Access to the guard tower public address speakers is via a desk-top mounted microphone as shown on the plans. To prevent feedback a feedback destroyer shall be employed.

Central Control shall not have access to the paging speakers on the towers outside of the perimeter fence. Central Control shall have access to the paging speakers on the compound tower on the facility all call paging function. Access from the compound tower shall have priority over the access from Central Control. (USP only)

F.

Refer to SECTION 17170 - Security monitoring and control system for operation of the paging system.

PART 2 - PRODUCTS

2.1

INTERIOR CEILING MOUNTED SPEAKER - TYPE A:

A.

Speaker shall be flush mounted for drop ceilings and surface mounted in exposed structure applications.

B.

Flush mounted speaker shall be a 200 mm, flush, ceiling mounted assembly as required for ceiling type.

1.

Baffle shall be cast aluminum with a cold rolled steel "checker board" reinforced speaker grill. Baffle shall be secured to the back box with tamper proof hardware. Baffle shall be square. Baffle shall be finished in textured white epoxy. Baffle shall be Soundolier VP161 series or other product approved by the

Contracting Officer.

2.

Speaker: A 200mm loud speaker with 25/70.7 volt transformer with at least 4 taps.

a.

Power Handling: 15 Watts (Continuous) b.

Frequency Response: 50-18,000 Hz c.

Impedance: 8 ohms d.

Dispersion: 105°

GENERAL PAGING SYSTEM 17260-3

e.

Cone Material: Treated Paper.

f.

The speaker shall be Soundolier C5A series or other product approved by the Contracting Officer.

3.

Back box: Shall be a minimum of 150mm deep. Shall be square and designed for acoustical applications. Shall be intended for mounting recessed mount speakers. Shall accommodate a 200mm loud speaker. Shall be undercoated to prevent acoustical and mechanical resonance. Shall be 20-gauge cold rolled steel. Shall be Soundolier 193-8-6 or other product approved by the Contracting

Officer.

C.

Surface mounted speaker shall be 200 mm, surface, ceiling mounted assembly.

1.

Baffle shall be cast aluminum with a cold rolled steel "checker board" reinforced speaker grill. Baffle shall be secured to the back box with tamper proof hardware. Baffle shall be square. Baffle shall be finished in textured white epoxy. Baffle shall be Soundolier VP161 series or other product approved by the

Contracting Officer.

2.

Speaker: An 200mm loud speaker with 25/70.7 volt transformer with at least 4 taps.

a.

Power Handling: 15 Watts (Continuous) b.

Frequency Response: 50-18,000 Hz c.

Impedance: 8 ohms d.

Dispersion: 105° e.

Cone Material: Treated Paper.

f.

The speaker shall be Soundolier C5A series or other product approved by the Contracting Officer.

3.

Back box: Shall be a minimum of 150mm deep. Shall be square and designed for acoustical applications. Shall be intended for mounting surface mount speakers. Shall accommodate a 200mm loud speaker. Shall be undercoated to prevent acoustical and mechanical resonance. Shall be 20-gauge cold rolled steel. Shall be Soundolier L20-213 or other product approved by the Contracting

Officer.

GENERAL PAGING SYSTEM 17260-4

2.2

EXTERIOR RECESSED WALL MOUNTED SPEAKER - TYPE B:

A.

Baffle shall be cast aluminum with a cold rolled steel "checker board" reinforced speaker grill. Baffle shall be secured to the back box with tamper proof hardware. Baffle shall be square. Baffle shall be finished in textured white epoxy. Baffle shall be supplied with horn adapter plate to accommodate horn speaker. Baffle shall be Soundolier VP161 series or other product approved by the Contracting Officer.

B.

Speaker shall be all metal, double re-entrant, waterproof loudspeaker for recessed installation. Speaker shall be rated at 15 watts RMS and be equipped with built-in transformer.

1.

Power: 15 Watts (Continuous)

20 Watts (Equalized)

2.

Frequency: 475-14,000 Hz

3.

Sound Level: 121 dB (1200 mm on axis @ continuous rated power)

4.

Dispersion: 180°

5.

Impedance (Ohms): 5000, 2500, 1300, 666, 333, 89, 45

6.

Power Selector (Watts): 70V; .9, 1.8, 3.8, 7.5, 15

25V; .48, .94, 1.8, 7.5, 15

7.

Dimensions: 142.8 mm diameter x 131 mm deep

8.

Weight: 1.6 kg

9.

Speaker shall be Atlas Model APF-15T or other product approved by the

Contracting Officer.

C.

Back box: Shall be a minimum of 150mm deep to accommodate large horn speaker.

Shall be square and designed for acoustical applications. Shall be intended for mounting recessed mount speakers. Shall accommodate a 140mm deep horn speaker. Shall be undercoated to prevent acoustical and mechanical resonance. Shall be 20-gauge cold rolled steel. Shall be Soundolier 193-8-6 or other product approved by the Contracting

Officer.

2.3

EXTERIOR SURFACE MOUNTED HORN SPEAKER - TYPE C:

A.

Speaker shall be high efficiency, double re-entrant, horn type speaker with 120o x 60o sound dispersion. Speaker shall be rated at 30 watts RMS and equipped with built-in

GENERAL PAGING SYSTEM 17260-5

transformer and adjustable mounting bracket. Unit shall be weatherproof, shockproof and vandal resistant.

1.

Power: 30 Watts (Continuous)

40 Watts (Equalized)

2.

Frequency: 300-12,000 Hz

3.

Sound Level: 123 dB

4.

Dispersion: 70° x 95°

5.

Impedance (ohms): 2500, 1300, 666, 333, 167, 89, 45

6.

Power Selector (Watts): 70V, 1.8, 3.7, 7.5, 15, 30

25V; 1.8, 3.7, 7.5, 15

7.

Dimensions: 360 mm W x 210 mm H x 330 mm D8.

8.

Weight: 3.6 kg

9.

Speaker shall be Atlas Model APC-30T or other product approved by the

Contracting Officer.

B.

Where shown on the plans the speakers shall be tower mounted. (FCI only)

1.

The paging tower shall be 8300 mm free-standing, constructed of galvanized steel, and equipped with a base plate, top plate, and a 3000 mm anti-climb shield.

(FCI only)

2.

The tower foundation shall be as shown on the drawings. (FCI only)

3.

The tower shall be Rohn Model 25G series or approved equal. (FCI only)

2.4

INTERIOR FLUSH WALL MOUNTED SPEAKER - TYPE D:

A.

Baffle shall be cast aluminum with a cold rolled steel "checker board" reinforced speaker grill. Baffle shall be secured to the back box with tamper proof hardware. Baffle shall be square. Baffle shall be finished in textured white epoxy. Baffle shall be Soundolier

VP161 series or other product approved by the Contracting Officer.

B.

Speaker: An 200mm loud speaker with 25/70.7 volt transformer with at least 4 taps.

1.

Power Handling: 15 Watts (Continuous)

2.

Frequency Response: 50-18,000 Hz

GENERAL PAGING SYSTEM 17260-6

3.

Impedance: 8 ohms

4.

Dispersion: 105°

5.

Cone Material: Treated Paper.

6.

The speaker shall be Soundolier C5A series or other product approved by the

Contracting Officer.

C.

Back box: Shall be a maximum of 95mm deep for wall installations. Shall be square and designed for acoustical applications. Shall be intended for mounting recessed mount speakers. Shall accommodate a 200mm loud speaker. Shall be undercoated to prevent acoustical and mechanical resonance. Shall be made of cold rolled steel. Shall be

Soundolier 193-8 or other product approved by the Contracting Officer.

2.5

MIXER POWER AMPLIFIER:

A.

Mixer power amplifier shall be provided for audio distribution as shown on the plans.

The mixer power amplifier shall have the following features:

1.

Shall be an 8 channel modular mixer/power amplifier.

2.

Every input port shall accept a modular plug-in input module to accept input signals of all different levels and types. Unless noted otherwise plug-in input module shall be a line matching transformer for a balanced audio input.

3.

Shall be listed and marked for use with Class 2 or Class 3 wiring.

4.

Output power shall be 120 W RMS. Line voltage shall be 70 volt balanced.

5.

Shall be powered by 120V - 60 Hz single phase power source. Power

Consumption shall be 180 Watts

6.

Frequency response shall be from 20 Hz to 15000 Hz.

7.

Shall be provided with 8 input gain controls, 1 master gain control, 1 bass tone control, 1 treble tone control, and an on/off switch.

8.

Shall be provided with remote muting capabilities with a screw terminal strip.

9.

Shall be 19 inch rack mounted.

10.

Unit shall be as manufactured by TOA Model A-912MK2 other product approved by the Contracting Officer.

GENERAL PAGING SYSTEM 17260-7

2.6 DESK TOP MICROPHONE: (FCI, USP only)

A.

The desktop microphone shown on the plans shall have the following features: (FCI, USP only)

1.

Element Dynamic (FCI, USP only)

2.

Pattern Unidirectional, cardioid (FCI, USP only)

3.

Frequency Response 100 to 10,000 Hz (FCI, USP only)

4.

Switch Integral push bar in base. (FCI, USP only)

5.

Unit shall be as manufactured by TOA Model PM-660U or other product approved by the Contracting Officer. (FCI, USP only)

2.7 CEILING MICROPHONE (USP only)

A.

The ceiling microphone shown on the plans shall have the following features: (USP only)

1.

Type Pressure Zone Microphone (USP only)

2.

Element Electret (USP only)

3.

Pattern Hemispherical (USP only)

4.

Frequency Response 80 to 20,000 Hz (USP only)

5.

Unit shall be as manufactured by Crown Model PZM-11 or other product approved by the Contracting Officer. (USP only)

B.

Adjust the system as required to prevent feedback. (USP only)

2.8 FEEDBACK DESTROYER (FCI, USP only)

A.

The feedback destroyer shall automatically and intelligently search out and destroy up to

12 frequencies using a 24-bit A/D and D/A converter. The feedback destroyer shall have the following features: (FCI, USP only)

1.

Input Impedance 60K ohms balanced. (FCI, USP only)

2.

Output Impedance 60 ohms balanced. (FCI, USP only)

3.

Audio Bandwidth: 20 Hz - 20 KHz. (FCI, USP only)

GENERAL PAGING SYSTEM 17260-8

4.

Total Harmonic Distortion: Less than 0.0075%. (FCI, USP only)

5.

Digital Sampling Rate: 46 KHz. (FCI, USP only)

6.

Rack mounted. (FCI, USP only)

7.

Unit shall be as manufactured by Behringer model DSP11XXP series or other product approved by Contracting Officer. (FCI, USP only)

2.9

ATTENUATORS

A.

Wall mounted attenuators shall be auto-transformer type Soundolier AT- 10 series with

1-1/2 dB/step increments and stop, or other product approved by the Contracting Officer.

Attenuators shall be equipped with wall plates identical to plates furnished by Division

16 for receptacles and light switches.

2.10

WIRE AND CABLE

A.

Wire and cable shall be of a type and size as recommended by the equipment manufacturer.

B.

Paging Station Cable

1.

All paging station cable shall be single or multiple stranded, twisted pairs minimum 18 AWG. Sized shall be as required to accommodate the total circuit load.

2.

Cable installed in exterior duct bank shall be direct burial type and shall be multiple stranded, shielded, twisted pairs 18 AWG minimum. (FCI, USP only)

C.

Microphone Cable

1.

Microphone cable shall be minimum 22 AWG, shielded, twisted pair.

PART 3 - EXECUTION

3.1

GENERAL

A.

Verify that conduit shown on the Drawings is adequate to support the proposed system.

If additional conduits are required or changes are required in size, make required changes to the drawings and notify Division 16 subcontractor. All changes in the conduit facilities shall be made at no additional cost to the Government.

B.

Equipments shall be rack mounted in cabinets to be furnished and installed under this

Section of work.

GENERAL PAGING SYSTEM 17260-9

C.

Refer to drawings for placement of equipment and panels. Coordinate with other trades which impact installation of these systems. Refer to schematic diagrams and point schedules for system interconnections.

D.

Cables shall be furnished and installed as required to support the systems as specified.

E.

Perform testing of all paging speakers and change tap settings as required to effect adequate audio levels. Unless noted otherwise on the drawings, set all taps at middle level for initial installation, adjust amplifier output for nominal setting, and then change individual speakers to meet the requirements of specific areas.

F.

Audio switching shall be noise-free. The paging system shall have no audible noise in the absence of an input signal. There shall be no "his", "hum", or "pop". All paging amplifiers shall be muted by the PLC system when not in use.

G.

Field coordinate installation of paging speakers to ensure speakers are accessible and so that the acoustical energy is not "attenuated" by other equipment and devices installed by other trades.

3.2

COMPLETION

A.

General: Upon completion of the work, remove excess debris, materials, equipment, apparatus, tools and the like and leave the premises clean, neat and orderly.

B.

Testing: The completed system shall be tested by the Contractor prior to the acceptance test.

END OF SECTION 17260