IFB 27011 Addendum 1 Drawings Part 1 Revised.pdf
PDF 10 MB Posted
- Attached to
- 27011-JS Godwin - Pilot Building Renovation
- Solicitation number
- IFB-123940
- Issued by
- Suffolk City, Virginia
About this file
This is Addendum 1 to the Invitation for Bid (IFB) 27011 for the City of Suffolk, Virginia, containing revised architectural and engineering drawings for the Godwin-Virginian Pilot Building renovation project located at 157 N. Main Street, Suffolk, VA. The project scope encompasses a comprehensive renovation of the existing Virginian Pilot Building to accommodate current and future needs of Godwin Courts, including the creation of private offices, open office spaces, conference rooms, breakrooms, a fitness room, and restrooms. The work includes roof replacement involving removal and replacement of existing single-ply membrane roofing, roof insulation, rooftop metal flashings, copings, repair or replacement of damaged metal roof deck as needed, replacement of internal roof drain fittings, emergency overflow scuppers, and extension of ventilation terminations and equipment curbs to achieve minimum flashing heights. Site improvements to the parking lot on Saratoga Street behind the building will include a new parking layout. The project must conform to the 2021 Virginia Construction Code and 2021 Virginia Existing Building Code, classified as Type II-B construction for Group B occupancy.
The renovation constitutes a Level 1 alteration under the Virginia Existing Building Code with roof replacement exceeding 75 percent of the roof area, requiring compliance with Virginia Energy Conservation Code standards for minimum thermal resistance of R-30 continuous insulation. All contractors must visit the site prior to bidding to verify existing conditions; submission of a bid proposal constitutes evidence of site inspection and acceptance of project conditions. The contractor bears full responsibility for coordination among all trades, proper demolition and disposal of materials, protection of existing materials to remain, temporary shoring and bracing, patching and repairs to match existing finishes, and maintaining the premises in an orderly, dust-free condition throughout construction. Specific requirements include saw-cutting concrete slabs for utility work, proper firestopping at fire-rated partitions, installation of pressure-treated lumber with corrosion-resistant fasteners for exterior applications, daily cleanup, and final cleaning with sealer application to exposed concrete floors upon project completion.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M D G
STRUCTURAL ENGINEERS
192 Ballard Court, Suite 102 Virginia Beach, Virginia 23462 Phone (757) 965-2000 Fax (757) 965-2001 www.mdg-eng.com
1277 Perimeter Pkwy Virginia Beach, Virginia 23454 Phone (757) 499-7223
NEW
PARKING
LOT
157 N.
MAIN ST
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
1 2 3 4 5 6
A
B
C
D
E
SHEET NAME:
PROJECT NO:
DATE ISSUED:
SHEET NO:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
IS
S
U A
N C
E S
C H
E D
U L
E
N U
M B
R
A
T
S
C R
IP
T
IO
10015069.02 ut od es k D oc s:
//S uf fo lk
V A
C ity P ro je ct s
H U
B _B
0_
R
/G od w in
-V irg in ia n P ilo t_
R en o_ A
R C
H _R
.r vt
7/
/2
:0 8:
A
M
COVER SHEET
G-001
N. DUNLEVY
MIJAL / MILLER
K. BARKER
06/17/2026
G O
D W
IN
V
IR
G
IN
IA
N
P
IL
O T
B U
IL
D
IN
G
C
IT
Y O
F S
U F
F O
LK
, V
A
N . M
A
IN
S T
. S U
F F
O
LK
V A
R E
N O
V A
T
IO
N
VICINITY MAP
LOCATION MAP
PROJECT TEAM PROJECT IMAGE SHEET INDEX
CITY OF SUFFOLK, VA
GODWIN - VIRGINIAN PILOT BUILDING
06/17/2026
BID DOCUMENTS
157 N MAIN STREET SUFFOLK, VA 23434
RENOVATION
SHEET
NUMBER SHEET NAME
GENERAL
G-001 COVER SHEET
G-002 GENERAL NOTES
CIVIL
CA001 COVER
CA002 GENERAL NOTES
CA003 GENERAL NOTES
CA004 GENERAL NOTES
CA005 GENERAL NOTES
SV100 SARATOGA EAST TOPOGRAPHIC SURVEY
SV101 SARATOGA EAST TOPOGRAPHIC SURVEY
SV102 SARATOGA EAST TOPOGRAPHIC SURVEY
CD100 DEMO & ES
CD500 DEMO & ES DETAILS
CD501 DEMO & ES NARRATIVE
CS100 SITE PLAN
CS500 SITE PLAN DETAILS
CS501 CONSTRUCTION DETAILS
CS502 CONSTRUCTION DETAILS
CG100 GRADING PLAN
CP100 PLANTING PLAN
CP500 PLANTING PLAN DETAILS
ES001 GENERAL NOTES LEGEND AND ABBREVATIONS
ES002 SITE PHOTOMETRIC PLAN
ES003 ELECTRICAL SITE PLAN
ES501 DETAILS
ES701 SPECIFICATIONS
LIFE SAFETY
LS001 CODE SUMMARY
LS101 LIFE SAFETY PLAN
HAZMAT
H-001 HAZMAT GENERAL NOTES & PHOTOS
H-101 FIRST FLOOR PLAN - HAZMAT REMOVAL
H-102 SECOND FLOOR PLAN AND ROOF - HAZMAT REMOVAL
H-103 ROOF PLAN - HAZMAT REMOVAL
STRUCTURAL
S-001 GENERAL NOTES
S-002 TYPICAL DETAILS AND ABBREVIATIONS
S-003 TYPICAL DETAILS
S-101 FIRST FLOOR PLAN - NEW WORK
S-102 PARTIAL SECOND FLOOR FRAMING PLANS AND SECTIONS
S-103 OVERALL ROOF PLAN - NEW WORK
S-104 PARTIAL ROOF FRAMING PLAN AND SECTIONS
S-105 PARTIAL ROOF FRAMING PLANS, SECTIONS AND DETAILS
ARCHITECTURE
A-001 SYMBOLS AND ABBREVIATIONS
A-002 PARTITION TYPES
AD101 OVERALL FIRST FLOOR PLAN - DEMOLITION
AD102 OVERALL SECOND FLOOR PLAN - DEMOLITION
AD111 OVERALL FIRST FLOOR REFLECTED CEILING PLAN - DEMOLITION
AD112 OVERALL SECOND FLOOR REFLECTED CEILING PLAN - DEMOLITION
AD121 OVERALL ROOF PLAN - DEMOLITION
AD201 BUILDING ELEVATIONS - DEMOLITION
AD301 WALL SECTIONS - DEMOLITION
AD501 EXISITNG CONDITION PICTURES
A-101 OVERALL FIRST FLOOR PLAN - NEW WORK
A-102 OVERALL SECOND FLOOR PLAN - NEW WORK
A-111 OVERALL FIRST FLOOR REFLECTED CEILING PLAN - NEW WORK
A-112 OVERALL SECOND FLOOR REFLECTED CEILING PLAN - NEW WORK
A-121 OVERALL ROOF PLAN - NEW WORK
A-201 BUILDING ELEVATIONS - NEW WORK
A-301 WALL SECTIONS - NEW WORK
A-401 ENLARGED RESTROOM PLANS AND ELEVATIONS, TOILET ACCS SCHEDULE
A-402 ENLARGED RESTROOM PLANS AND ELEVATIONS
A-403 ENLARGED SHOWER ROOM PLANS AND ELEVATIONS
A-404 ENLARGED BREAK ROOM PLANS AND ELEVATIONS
A-405 INTERIOR ELEVATIONS
A-406 INTERIOR ELEVATIONS
A-407 TYPICAL PLUMBING FIXTURE AND TOILET ACCESSORIES MOUNTING HEIGHTS
A-501 CEILING AND PARTITION DETAILS
A-502 PLAN DETAILS
PROJECT LOCATION:
PROJECT NAME:
GOVERNING BUILDING CODE:
PROJECT TYPE:
157 N. MAIN ST. SUFFOLK, VA 23434
GODWIN - VIRGINIAN PILOT BUILDING RENOVATION
VIRGINIA UNIFORM BUILDING CODE (2021 VIRGINIA CONSTRUCTION CODE, 2021 VIRGINIA EXISTING BUILDING CODE)
THE EXISTING VIRGINIAN PILOT BUILDING WILL BE RENOVATED TO ACCOMODATE CURRENT AND FUTURE NEEDS OF GROWING GODWIN COURTS. THE BUILDING WILL INCLUDE SPACE FOR PRIVATE OFFICES, OPEN OFFICE, CONFERENCE ROOMS, BREAKROOMS, FITNESS ROOM AND RESTROOMS. THE REMOVAL AND REPLACEMENT OF EXISTING ROOFING SINGLE-PLY MEMBRANE AND ROOF INSULATION WITH NEW SINGLE-PLY MEMBRANE, ROOF INSULATION, ROOF TOP METAL FLASHINGS, COPINGS, REPAIR/REPLACEMENT OF DAMAGED METAL ROOF DECK AS NEEDED AND REPLACEMENT OF INTERNAL ROOF DRAIN FITTINGS. SCOPE INCLUDES THE REPLACEMENT OF EMERGENCY OVERFLOW SCUPPERS, EXTENSION OF VTR'S, AND EF CURBS TO OBTAIN MINIMUM FLASHING HEIGHTS ABOVE FINAL ROOF FINISH. PARKING LOT ON SARATAGO STREET BEHIND THE BUILDING WILL UNDERGO SITE IMPROVEMENTS AND A NEW PARKING LAYOUT.
SHEET
NUMBER SHEET NAME
A-521 ROOF DETAILS - DEMOLITION & NEW WORK
A-522 ROOF DETAILS - DEMOLITION & NEW WORK
A-523 ROOF DETAILS - DEMOLITION & NEW WORK
A-524 ROOF DETAILS - NEW WORK
A-525 ROOF DETAILS - DEMOLITION & NEW WORK
A-551 MISCELLANEOUS DETAILS
A-601 DOOR SCHEDULE AND DOOR TYPES
A-602 DOOR DETAILS
A-603 STOREFRONT ELEVATIONS
A-604 STOREFRONT DETAILS
A-701 FINISH SCHEDULE AND LEGEND, EQUIPMENT SCHEDULE
A-702 OVERALL FIRST FLOOR FINISH PLAN
A-703 OVERALL SECOND FLOOR FINISH PLAN
A-704 TRANSITION AND FINISH DETAILS
A-801 OVERALL FIRST FLOOR SIGNAGE PLAN
A-802 SIGNAGE SCHEDULE AND DETAILS
A-803 SIGNAGE LEGEND
PLUMBING
P-001 LEGEND, NOTES AND ABBREVIATIONS
P-002 FIXTURE PLATES
PD-101 OVERALL FIRST FLOOR PLAN - DEMOLITION
PD-102 OVERALL ROOF PLAN - DEMOLITION
P-101 OVERALL FIRST FLOOR SANITARY PLAN - NEW WORK
P-102 OVERALL ROOF PLAN - NEW WORK
P-201 OVERALL FIRST FLOOR DOMESTIC WATER PLAN - NEW WORK
P-501 RISERS, SCHEDULES, AND DETAILS
MECHANICAL
M-001 LEGEND, NOTES AND ABBREVIATIONS
MD-101 OVERALL FIRST FLOOR MECHANICAL PLAN - DEMOLITION
MD-102 OVERALL SECOND FLOOR MECHANICAL PLAN - DEMOLITION
MD-103 OVERALL ROOF PLAN - DEMOLITION
M-101 OVERALL FIRST FLOOR DUCTWORK PLAN - NEW WORK
M-102 OVERALL SECOND FLOOR DUCTWORK PLAN - NEW WORK
M-202 OVERALL SECOND FLOOR PIPING PLAN - NEW WORK
M-201 OVERALL FIRST FLOOR PIPING PLAN - NEW WORK
M-203 OVERALL ROOF MECHANICAL PLAN - NEW WORK
M-501 DETAILS
M-502 DETAILS
M-503 DETAILS
M-601 SCHEDULES
M-602 SCHEDULES
M-701 CONTROLS
M-702 CONTROLS
M-703 CONTROLS
ELECTRICAL
E-001 NOTES AND ABBREVIATIONS
E-002 LEGEND
ED101 OVERALL FIRST FLOOR ELECTRICAL PLAN - DEMOLITION
ED102 PARTIAL SECOND FLOOR PLAN - DEMOLITION
ED103 ROOF POWER PLAN - DEMOLITION
E-101 OVERALL FIRST FLOOR LIGHTING PLAN - NEW WORK
E-102 PARTIAL SECOND FLOOR PLAN - NEW WORK
E-201 OVERALL FIRST FLOOR POWER PLAN - NEW WORK
E-202 OVERALL ROOF POWER PLAN - NEW WORK
E-301 OVERALL FIRST FLOOR SPECIAL SYSTEMS PLAN - NEW WORK
E-501 LIGHTING DETAILS
E-502 LIGHTING DETAILS
E-503 DETAILS
E-504 DETAILS
E-505 DETAILS
E-601 POWER RISER DIAGRAM - DEMOLITION
E-602 POWER RISER DIAGRAM - NEW WORK
E-603 SPECIAL SYSTEMS RISER DIAGRAMS
E-604 PANEL SCHEDULES
E-605 SCHEDULES
ARCHITECTURE ENGINEERING GEOSPATIAL
GEOENVIRONMENTAL RESOURCES, INC.
Consulting Engineers
PROJECT INFORMATION
/1
/2
A
M E
N D
M E
N T
PROJECT SITE
PROJECT SITE
Lic. No. 013830
JASON A. MILLER
L
O C
I
NI
G
RI
VF
OHTAE
W
N O M
M
A
A HCRDE
C
ERT
I
IF
CET
T
I
8:53:32
AM
06/18/2026 Lic. No. 0401013830
06/17/2026
" H
O
LD
INSTALL ADA CANE APRON ON
STANDING DRINKING FOUNTAIN
1. ALL DIMENSIONS TO BE VERIFIED IN FIELD PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT OF ALL
DISCREPANCIES PRIOR TO STARTING WORK.
2. ALL EXISTING MATERIALS TO REMAIN WHICH ARE DAMAGED OR OTHERWISE DISTURBED BY THE CONTRACTOR'S OPERATIONS SHALL BE PATCHED AND REPAIRED TO MATCH EXISTING ADJACENT MATERIALS
SO THAT REPAIR IS IMPERCEPTIBLE.
3. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR OTHER DISCIPLINE DEMOLITION SCOPE
OF WORK.
4. CONTRACTOR SHALL MAINTAIN ALL REQUIRED EXITS UNOBSTRUCTED, ILLUMINATED AND PROTECTED FROM
CONSTRUCTION ACTIVITIES.
5. CONTRACTOR TO CLEAN AREAS ADJACENT TO DEMOLITION AREA OF DUST, DIRT AND DEBRIS CAUSED BY
DEMOLITION OPERATIONS.
6. PROMPTLY DISPOSE OF DEMOLISHED MATERIALS. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE
ON-SITE. TRANSPORT DEMOLISHED MATERIALS AND LEGALLY DISPOSE OF THEM.
7. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY CONFLICTS BETWEEN EXISTING CONSTRUCTION AND
CONSTRUCTION DOCUMENTS.
8. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS WITH EACH OTHER AND SHALL IMMEDIATELY REPORT ANY ERRORS, INCONSISTENCIES OR OMISSIONS TO THE OWNER'S REPRESENTATIVE. IF THE CONTRACTOR PERFORMS ANY CONSTRUCTION ACTIVITY KNOWING IT INVOLVES A RECOGNIZED ERROR, INCONSISTENCY OR OMISSION IN THE CONTRACT DOCUMENTS WITHOUT SUCH NOTICE TO THE CONTRACTING OFFICER OR OWNER'S REPRESENTATIVE, THE CONTRACTOR SHALL ASSUME APPROPRIATE RESPONSIBILITY FOR SUCH PERFORMANCE AND SHALL BEAR AN APPROPRIATE AMOUNT OF THE ATTRIBUTABLE COSTS FOR CORRECTION. THE CONTRACTOR SHALL TAKE FIELD MEASUREMENTS, VERIFY FIELD CONDITIONS AND OTHER INFORMATION BEFORE COMMENCING ACTIVITIES. ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED SHALL BE REPORTED TO THE CONTRACTING OFFICER OR
OWNER'S REPRESENTATIVE AT ONCE.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, GRINDING, SANDING, FILLING, FITTING OR PATCHING REQUIRED TO COMPLETE THE WORK OR TO MAKE THE PARTS FIT TOGETHER PROPERLY.
10. THE CONTRACTOR SHALL NOT DAMAGE OR ENDANGER A PORTION OF THE WORK OR FULLY OR PARTIALLY COMPLETED CONSTRUCTION BY CUTTING, PATCHING OR OTHERWISE ALTERING SUCH CONSTRUCTION. THE CONTRACTOR SHALL NOT CUT OR OTHERWISE ALTER SUCH CONSTRUCTION BY OTHER CONTRACTORS OR BY THE OWNER'S REPRESENTATIVE OWN FORCES EXCEPT WITH WRITTEN CONSENT OF THE OWNER'S REPRESENTATIVE AND SUCH OTHER CONTRACTORS; SUCH CONSENT SHALL NOT BE UNREASONABLY
WITHHELD.
11. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGE THAT OCCURS TO EXISTING MATERIALS, FINISHES, EQUIPMENT, ETC. TO REMAIN AS A RESULT OF THE CONTRACTOR'S WORK. IF DAMAGE TO EXISTING MATERIALS, FINISHES, EQUIPMENT, ETC. TO REMAIN DOES OCCUR AS A RESULT OF THE CONTRACTOR'S WORK, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING AS REQUIRED OR FOR PROVIDING COMPLETE REPLACEMENT AS PER THE DIRECTION OF THE OWNER'S REPRESENTATIVE.
12. CONTRACTOR SHALL PROVIDE ALL TEMPORARY SHORING AND BRACING AS REQUIRED FOR ALL DEMOLITION AND NEW WORK. IF ANY DAMAGE OCCURS TO THE EXISTING BUILDING OR NEW CONSTRUCTION AS A RESULT OF IMPROPER OR INADEQUATE SHORING OR BRACING, THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR REPAIR AND/ OR REPLACEMENT OF DAMAGED AREAS. DAMAGED AREAS SHALL INCLUDE BUT NOT BE LIMITED TO STRUCTURE, WINDOWS, FINISHES, EQUIPMENT, AND FURNISHINGS.
13. CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING STRUCTURES, UTILITIES, MECHANICAL/
ELECTRICAL/ PLUMBING COMPONENTS, FINISHES, ETC., THAT IS SHOWN ON THE DEMOLITION
AND RENOVATION, ARCHITECTURAL, MECHANICAL, PLUMBING/ FIRE PROTECTION, OR
ELECTRICAL DRAWINGS. THIS SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO THE FOLLOWING:
a. WHERE EXISTING WALL MUST BE PATCHED, OR OTHERWISE REFINISHED TO MATCH
EXISTING; PROVIDE NEW FINISHES FOR ENTIRE WALL, OR TO NEAREST WALL BREAK /
CORNER.
b. AT STRUCTURES TO BE REMOVED; INCLUDING CONCRETE MASONRY UNIT PARTITIONS AND
WALLS, METAL STUD PARTITIONS AND WALLS, GYPSUM BOARD AND/ OR PLASTER CEILINGS,
ETC., PARTITIONS AND WALLS SHALL BE SAW CUT WITH SMOOTH AND STRAIGHT EDGES AS
REQUIRED FOR NEW ADJACENT CONSTRUCTION.
14. ALL EQUIPMENT THAT IS TO BE PLACED IN STORAGE OR SALVAGED FOR THE OWNER'S
REPRESENTATIVE SHALL HAVE THE EQUIPMENT NUMBER SHOWN ON THE EQUIPMENT DRAWINGS
NEATLY AND SHALL BE LEGIBLY MARKED ON THE EQUIPMENT WITH PERMANENT BLACK, WIDE TIP
MARKER IN AN OBVIOUS LOCATION. ALL LOOSE EQUIPMENT ACCESSORIES SUCH AS
FASTENERS, FITTINGS, ACCESSORIES, ETC., SHALL BE PLACED IN A CLEAR, HEAVY DUTY PLASTIC
BAG. THE BAG SHALL BE SEALED AND LABELED BY EQUIPMENT NUMBER AND TAPED TO
EQUIPMENT WITH CLEAR, WIDE, HEAVY DUTY TAPE.
15. SAW CUT EXISTING CONCRETE SLAB FOR ALL REQUIRED UTILITY DEMOLITION, MASONRY WALL DEMOLITION, NEW UTILITY INSTALLATION AND NEW CONCRETE BLOCK WALL INSTALLATION, ETC.
ALL CUT CONCRETE SLABS SHALL BE PATCHED AND REPAIRED AS REQUIRED. SEE STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR MORE INFORMATION.
16. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THEIR WORK WITH ALL SURROUNDING
CONSTRUCTION ELEMENTS AND TRADES AFFECTED.
17. THE CONTRACTOR IS RESPONSIBLE FOR CREATING ALL OPENINGS, PENETRATIONS, LINTELS, ETC., AS REQUIRED TO PERFORM THEIR PORTION OF WORK.
18. AT EXISTING WALLS AND CEILINGS INDICATED TO BE PAINTED (REFER TO ROOM FINISH
SCHEDULE FOR LOCATIONS). THE CONTRACTOR SHALL REMOVE ANY WALL MOUNTED ITEMS
SUCH AS: SIGNS, MARKER BOARDS, TACK BOARDS, TACK STRIPS, SHELVES, PROJECTION
SCREENS, CLOCKS, ESCUTCHEON PLATES, ELECTRICAL COVER PLATES, AND ETC. PRIOR TO
PAINTING. EXISTING EXPOSED PIPING AND CONDUIT TO REMAIN AND SHALL BE PAINTED TO
MATCH ADJACENT WALL OR CEILING. UPON COMPLETION OF FINISH WORK/PAINTING -REINSTALL
ANY REMOVED ITEMS WHICH ARE TO BE PART OF FINISHED WORK. SEE DRAWINGS FOR NEW
WORK.
19. ALL DEMOLISHED ITEMS, UNLESS OTHERWISE NOTED, SHALL BE MOVED TO AN OFF SITE
LOCATION IN A LEGAL MANNER AND PER THE REQUIRED CONTRACTOR’S CONSTRUCTION AND
DEMOLITION WASTE PLAN.
20. SEE MECHANICAL/ ELECTRICAL/ PLUMBING/ FIRE PROTECTION DRAWINGS FOR NEW UTILITY
RUNS REQUIRING NEW OPENINGS IN WALLS, FLOOR SLABS OR CEILINGS.
21. COORDINATE DEMOLITION WORK SCOPE WITH ASSOCIATED DOCUMENTS FOR RENOVATION/ NEW
CONSTRUCTION WORK BY OTHER TRADES TO DETERMINE SIZES AND LOCATIONS OF OPENINGS
IN EXISTING WALLS, FLOORS, CEILINGS, AND PARTITIONS.
22. AT NEW OPENINGS AT EXISTING METAL STUD/GYPSUM BOARD PARTITIONS, FRAME IN A HEADER
AS REQUIRED TO SUPPORT FRAMING ABOVE THE OPENING PER THE METAL STUD
MANUFACTURER'S GUIDELINES.
1. CONSTRUCTION SHALL CONFORM TO ALL GOVERNING CODES, LOCAL CODES, ORDINANCES AND
REQUIREMENTS.
2. ALL CONTRACTORS SUBMITTING BID PROPOSALS FOR THIS PROJECT ARE REQUIRED TO VISIT THE SITE PRIOR TO BIDDING TO VERIFY EXISTING CONDITIONS AND FEASIBILITY OF DESIGN INTENT OF THESE CONSTRUCTION DOCUMENTS (CONSTRUCTION DRAWINGS AND SPECIFICATIONS). ANY VARIATION IN SITE CONDITIONS AND CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE CONTRACTING OFFICER OR OWNER'S REPRESENTATIVE'S ATTENTION IN WRITING IMMEDIATELY AND (10) BUSINESS DAYS PRIOR TO BID DATE, THE SUBMISSION OF BID PROPOSAL'S SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTOR HAS VISITED THE SITE, VERIFIED ITS CONDITIONS AND IS PREPARED TO PERFORM WORK AS INTENDED IN THESE DOCUMENTS. NO EXTRA PAYMENT'S SHALL BE ALLOWED DUE TO THE CONTRACTORS CLAIMS FOR EXTRA
WORK REQUIRED BY THEIR FAILURE TO VISIT THE SITE.
3. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE CONTRACTING OFFICER OR OWNER'S REPRESENTATIVE BEFORE
CONTINUING WITH THE WORK.
4. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THEIR WORK WITH ALL SURROUNDING
CONSTRUCTION ELEMENTS AND TRADES AFFECTED.
5. THE CONTRACTOR IS RESPONSIBLE FOR CREATING ALL OPENINGS, PENETRATIONS, LINTELS, ETC. AS REQUIRED TO PERFORM THEIR PORTION OF WORK. AT FIRE RATED PARTITIONS, CLOSE OPENINGS / PENETRATIONS / ETC. WITH FIRESTOPPING THAT MATCHES OR EXCEEDS THE PARTITION RATING.
6. ALL ITEMS REQUIRING COLOR SELECTION SHALL BE SELECTED BY THE CONTRACTING OFFICER OR OWNER'S REPRESENTATIVE DURING THE SUBMITTAL REVIEW FROM MANUFACTURERS' STANDARD OR FULL RANGE (AS
DIRECTED IN SPECIFICATION) OF COLORS.
7. IT IS THE CONTRACTOR'S RESPONSIBILITY FOR THE COORDINATION OF ALL DRAWINGS AND SPECIFICATIONS AS REQUIRED TO PERFORM THE WORK AS CALLED FOR, SHOWN AND REASONABLY IMPLIED IN THE
CONTRACT DOCUMENTS.
8. ASBESTOS CONTAINING MATERIALS SHALL NOT BE USED ON ANY PROJECT.
9. FINISH AND PAINT WALLS BEFORE INSTALLING CASEWORK, EQUIPMENT, FIXTURES, ELEC. PANELS, BOXES, SURFACE CONDUIT, ETC., IF APPLICABLE.
10. CONTRACTOR TO INSTALL WOOD OR METAL BLOCKING FOR ALL CASEWORK, EQUIPMENT, HANDRAILS, BATH
ACCESSORIES, FIXTURES, ETC. AS RECOMMENDED BY MANUFACTURER, IF NOT OTHERWISE SHOWN HEREIN.
11. ALL WOOD BLOCKING LOCATED OUTSIDE THE BUILDING ENVELOPE, IN EXTERIOR WALLS/ROOFS OR IN
CONTACT W/ CONCRETE OR MASONRY, SHALL BE PRESSURE TREATED LUMBER, AND FASTENED WITH SCREWS. ALL TREATED WOOD BLOCKING SHALL HAVE CORROSION RESISTANT STAINLESS STEEL OR
GALVANIZED FASTENERS.
12. IF DISCREPANCIES BETWEEN PLANS OR SPECIFICATIONS OCCUR THE CONTRACTOR SHALL NOTIFY THE
CONTRACTING OFFICER OR OWNER'S REPRESENTATIVE TREAT ANYTHING MENTIONED IN THE
SPECIFICATIONS BUT NOT SHOWN ON THE DRAWINGS OR SHOWN ON THE DRAWINGS BUT NOT INCLUDED IN THE SPECIFICATIONS AS IF SHOWN OR MENTIONED IN BOTH. IF DISCREPANCIES BETWEEN THE DRAWINGS
AND SPECIFICATIONS, THE SPECIFICATIONS TAKE PRECEDENCE.
13. FOR INSTALLATION OF ALL WORK WHICH IS DEPENDENT ON CONDITION OF SUBSTRATE, CAREFULLY INSPECT AND VERIFY SUITABILITY OF SUBSTRATE FOR INSTALLATION OF WORK. DO NOT INSTALL WORK OVER UNSUITABLE OR UNACCEPTABLE SUBSTRATES. CORRECT UNACCEPTABLE SUBSTRATES BEFORE INSTALLING WORK. CONTRACTOR IS RESPONSIBLE FOR ALL GRINDING, LEVELING, SANDING, PATCHING, ETC. TO CORRECT ALL SURFACES TO PREPARE FOR NEW FINISHES.
14. MOUNTING HEIGHTS OF ELECTRICAL, PLUMBING, MECHANICAL, AND OTHER DEVICES SHALL COMPLY WITH HEIGHTS INDICATED ON DRAWINGS. NOTIFY CONTRACTING OFFICER OR OWNER'S REPRESENTATIVE IF
CONFLICTS ARE ENCOUNTERED.
15. ALL EXPOSED METAL, METAL DECK, STRUCTURAL, BAR JOISTS, CONDUITS, PIPES, ANGLES, BRACKETS, DUCT, ETC. SHALL NOT BE PAINTED UNLESS NOTED OTHERWISE.
16. ALL EXPOSED CONCRETE FLOORS SHALL BE CLEANED AT THE END OF PROJECT AND HAVE A 2ND COAT OF
SEALER APPLIED.
16. THE CONTRACTOR SHALL ARRANGE FOR THE PREMISES TO BE MAINTAINED IN AN ORDERLY MANNER, FREE OF DUST AND DEBRIS,THROUGHOUT THE COURSE OF THE WORK. PROVIDE AND MAINTAIN
TEMPORARY BARRICADES AS REQUIRED TO PROTECT THE PUBLIC AND OWNERS PERSONNEL DURING
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING
STRUCTURE OR EQUIPMENT. ANY SUCH DAMAGE SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE.
17. CONTRACTOR SHALL PROVIDE DAILY OR MORE FREQUENT GENERAL CLEAN UP IN COMPLIANCE WITH OWNER'S REQUIREMENTS OF AREAS WITHIN THE LIMITS OF CONSTRUCTION, AND FINAL CLEAN UP AT
CONCLUSION OF WORK.
18. EXTERIOR DIMENSIONS ARE TO FACE OF MASONRY VENEER OR FACE OF STUD, OR COLUMN
CENTERLINE UNLESS OTHERWISE NOTED. INTERIOR DIMENSIONS ARE TO FACE OF EXTERIOR STUD, FACE OF MASONRY, FACE OF CONCRETE, CENTERLINE OF COLUMNS, OR FACE OF INTERIOR STUD
UNLESS OTHERWISE NOTED.
19. ALL MATERIALS, FIXTURES AND EQUIPMENT INDICATED IN THE CONSTRUCTION DOCUMENTS SHALL BE
NEW AND AS SPECIFIED, UNLESS IDENTIFIED OTHERWISE.
20. ALL NEW FINISHED AND PATCHED SURFACES SHALL BE SMOOTH, CONTINUOUSLY FREE OF
IMPERFECTIONS AND IN PROPER CONDITION TO RECEIVE THE SPECIFIED FINISH. PATCHED AREAS SHALL
MATCH THE ADJACENT MATERIALS CONSTRUCTION AND FINISH.
21. ALL FLOORS ON EITHER SIDE OF A DOORWAY OR OPENING SHALL BE LEVEL.
22. DOOR OPENINGS NOT LOCATED BY DIMENSION SHALL BE 4" FROM THE FACE OF STUD TO FACE OF STUD
OF DOOR FRAME JAMB UNLESS NOTED OTHERWISE.
23. DOOR SIZES, STYLES, AND SPECIFICATIONS, ROUGH OPENING SIZES AND EXACT LOCATIONS TO BE
CHECKED AND VERIFIED BY THE CONTRACTOR BEFORE ORDERING AND BEFORE CONSTRUCTION
BEGINS.
24. ALL PENETRATIONS OF FIRE RATED FLOORS, WALLS AND CEILINGS TO BE SEALED WITH PROPER
APPROVED MATERIALS TO THE FULL THICKNESS OF THE CONSTRUCTION ELEMENTS.
25. FIRE STOP ALL FLOORS, WALLS AND CEILINGS AS REQUIRED BY APPLICABLE CODE.
26. ALL WOOD BLOCKING IN EXTERIOR WALLS TO BE MOISTURE RESISTANT TREATED IN ACCORDANCE WITH
SPECIFICATIONS. WHERE REQUIRED BY CODE, ALL WOOD BLOCKING IN INTERIOR WALLS TO BE FIRE
RETARDANT TREATED IN ACCORDANCE WITH SPECIFICATIONS.
27. INSTALL SEALANT AT EXTERIOR SIDE OF ALL JOINTS, SEAMS, CONNECTIONS OR OPENINGS WHICH WOULD ALLOW WATER OR AIR INFILTRATION EXCEPT AS NOTED OTHERWISE. SEALANT COLOR TO
MATCH ARCHITECT'S SAMPLE. COLOR REQUIRES ARCHITECT'S APPROVAL.
28. PROVIDE FIRE EXTINGUISHER COMPLYING WITH NFPA 10, AS INDICATED ON LIFE SAFETY DRAWINGS.
29. MASONRY CONTROL JOINTS ARE SHOWN FOR REFERENCE ONLY, LOCATIONS OF CONTROL JOINTS
SHALL BE PER THE NATIONAL BRICK INDUSTRY ASSOCIATION GUIDELINES.
30. THE LOCATIONS OF EXISTING UTILITIES HAVE BEEN PREPARED FROM DOCUMENTS PROVIDED BY THE
OWNER AND MAY NOT REPRESENT THE ACTUAL FIELD CONDITIONS. CONTRACTOR TO REVIEW ALL OWNER DOCUMENTS AND BECOME FAMILIAR WITH ALL EXISTING UTILITIES. THE CONTRACTOR HAS THE RESPONSIBILITY TO VERIFY LOCATIONS IN THE FIELD BY EMPLOYING FIELD UTILITY LOCATING SERVICES BEFORE CONSTRUCTION STARTS, AND COORDINATE ALL NEW UTILITY LOCATIONS, CONNECTIONS AND
PENETRATIONS.
31. THE SUBCONTRACTOR SHALL VERIFY AND COORDINATE, WITH ALL TRADES, THE SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, EQUIPMENT PADS, OR BASES AS WELL AS POWER, WATER, AND DRAIN INSTALLATIONS BEFORE PROCEEDING WITH WORK.
SUBCONTRACTOR SHALL PROVIDE COORDINATION DRAWINGS FOR PROPER PLACEMENT OF ALL TRADES' WORK. ALL CONCERNS, SPACE LIMITATIONS OR STRUCTURAL CONFLICTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT, PRIOR TO COMMENCING WITH THE WORK IN QUESTION.
32. IT IS THE SUBCONTRACTOR'S RESPONSIBILITY TO COORDINATE AND LOCATE ELECTRICAL, DATA, AND PHONE RECEPTACLES, SWITCHES, ETC. TO AVOID CONFLICTS WITH CASEWORK, DOORS, AND OTHER
TRADES.
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
1 2 3 4 5 6
A
B
C
D
E
SHEET NAME:
PROJECT NO:
DATE ISSUED:
SHEET NO:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
IS
S
U A
N C
E S
C H
E D
U
M B
S
C R
IP
T ut od es k D oc s:
//S uf fo lk
V A
C ity P ro je ct s
H U
B _B
0_
R
/G od w in
-V irg in ia n P ilo t_
R en o_ A
R C
H _R
.r vt
7/
/2
:0 8:
A
M
GENERAL NOTES
G-002
N. DUNLEVY
MIJAL / MILLER
K. BARKER
06/17/2026
G O
D W
IN
V
IR
G
IN
IA
N
P
IL
O T
B U
IL
D
IN
G
C
IT
Y O
F S
U F
F O
LK
, V
A
N . M
A
IN
S T
. S U
F F
O
LK
V A
R E
N O
V A
T
IO
N
GENERAL NEW CONSTRUCTION NOTES:
GENERAL DEMOLITION NOTES:
12" = 1'-0" D1
CANE APRON @ HI-LO WATER FOUNTAIN
0 1" 2" 3"
12"=1'-0"
GRAPHIC SCALE
DEFINITIONS:
REROOFING: THE PROCESS OF RECOVERING OR REPLACING AN EXISTING ROOF COVERING. SEE “ROOF RECOVER” AND “ROOF REPLACEMENT.”
ROOF COVERING: THE COVERING APPLIED TO THE ROOF DECK OR SPACED SUPPORTS FOR WEATHER RESISTANCE, ENERGY PERFORMANCE, FIRE CLASSIFICATION, OR APPEARANCE.
ROOF REPLACEMENT: THE PROCESS OF REMOVING THE EXISTING ROOF COVERING, REPAIRING ANY DAMAGED SUBSTRATE AND INSTALLING A NEW ROOF COVERING.
ROOF RECOVER: THE PROCESS OF INSTALLING AN ADDITIONAL ROOF COVERING OVER A PREPARED EXISTING ROOF COVERING WITHOUT REMOVING THE EXISTING ROOF COVERING.
VEBC 2021
601.2.1 LEVEL 1.
LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OR THE COVERING OF EXISTING MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES USING NEW MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES THAT SERVE THE SAME PURPOSE, OR THE REMOVAL WITHOUT REPLACEMENT OF MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES. LEVEL 1 ALTERATIONS SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF SECTION 602.
601.4 ENERGY CONSERVATION.
EXCEPT AS MODIFIED BY THIS SECTION, ALTERATIONS TO AN EXISTING BUILDING, BUILDING SYSTEM, OR STRUCTURE SHALL CONFORM TO THE APPLICABLE PROVISIONS OF THE VIRGINIA ENERGY CONSERVATION CODE (VECC) OR VIRGINIA RESIDENTIAL CODE (VRC) AS THEY RELATE TO NEW CONSTRUCTION WITHOUT REQUIRING THE UNALTERED PORTIONS OF THE EXISTING BUILDING, BUILDING SYSTEM, OR STRUCTURE TO COMPLY WITH THE VECC OR VRC.
601.4.5 ROOF REPLACEMENT.
ROOF REPLACEMENTS SHALL COMPLY WITH SECTION C402.2.1 AND SECTION C402.1.3, C402.1.4, C402.1.5, OR C407 OF THE VECC WHERE ALL OF THE FOLLOWING CONDITIONS ARE MET. FOR PURPOSES OF THIS SECTION, ROOF AREA SHALL MEAN AN AREA OF THE EXISTING ROOF OF THE SAME BUILDING THAT IS BOUNDED BY EXTERIOR WALLS, DIFFERENT ROOF LEVELS, ROOF EDGES OR PERIMETERS, ROOF DIVIDERS, BUILDING EXPANSION JOINTS, OR PARAPETS.
1. THE ROOF REPLACEMENT EXCEEDS 75 PERCENT OR 30,000 SQUARE FEET (2787.1 M2) OF THE ROOF AREA, WHICHEVER IS LESS. PROJECT = TRUE (100 PERCENT)
2. THE ROOF ASSEMBLY IS PART OF THE BUILDING THERMAL ENVELOPE, AS DEFINED BY THE VECC. PROJECT: TRUE
3. THE ROOF ASSEMBLY CONTAINS INSULATION ENTIRELY ABOVE THE ROOF DECK. PROJECT: TRUE
CODE SUMMARY (CONT):
VECC 2021
C402.1.3 ROOF ASSEMBLY R-VALUE. TABLE C402.1.3: R=30 C.I.
THE MINIMUM THERMAL RESISTANCE (R-VALUE) OF THE INSULATING MATERIAL INSTALLED EITHER BETWEEN THE ROOF FRAMING OR CONTINUOUSLY ON THE ROOF ASSEMBLY SHALL BE AS SPECIFIED IN TABLE C402.1.3, BASED ON CONSTRUCTION MATERIALS USED IN THE ROOF
ASSEMBLY.
C402.1.4 ROOF ASSEMBLY U-FACTOR. TABLE C402.1.4: U=0.032
C402.1.4.1.1. TAPERED, ABOVE-DECK INSULATION BASED ON THICKNESS. WHERE USED AS A COMPONENT OF A ROOF/CEILING ASSEMBLY R-VALUE CALCULATION, THE SLOPED ROOF INSULATION R-VALUE CONTRIBUTION TO THAT CALCULATION SHALL USE THE AVERAGE
THICKNESS IN INCHES (MM) ALONG WITH THE MATERIAL R-VALUE-PER-INCH (PER-MM) SOLELY FOR R-VALUE COMPLIANCE AS PRESCRIBED IN SECTION C402.1.3.
PROJECT: WHERE TAPERED INSULATION IS INDICATED THE PROJECT UTILIZES AN AVERAGE THICKNESS OF 2.5" TO 8" (OR GREATER) = 5.25" AVERAGE THICKNESS =
31.525 (R-VALUE) = 0.031721 (U-VALUE). CALCULATION INCLUDES 1/2" COVER BOARD (R-VALUE=0.55).
C402.2.1 ROOF ASSEMBLY. THE MINIMUM THERMAL RESISTANCE (R-VALUE) OF THE INSULATING MATERIAL INSTALLED EITHER BETWEEN THE ROOF FRAMING OR CONTINUOUSLY ON THE ROOF ASSEMBLY SHALL BE AS SPECIFIED IN TABLE C402.1.3, BASE ON THE CONSTRUCTION
MATERIALS USED IN THE ROOF ASSEMBLY.
C402.2.1.1 TAPERED, ABOVE-DECK INSULATION BASED ON THICKNESS. WHERE USED AS A COMPONENT OF A ROOF/CEILING ASSEMBLY R-VALUE CALCULATION, THE SLOPED ROOF INSULATION R-VALUE CONTRIBUTION TO THAT CALCULATION SHALL USE THE AVERAGE THICKNESS IN INCHES (MM) ALONG WITH THE MATERIAL R-VALUE-PER-INCH (PER-MM) SOLELY FOR R-VALUE COMPLIANCE AS PRESCRIBED IN SECTION C402.1.3.
PROJECT: WHERE TAPERED INSULATION IS INDICATED THE PROJECT UTILIZES AN AVERAGE THICKNESS OF 2.5" TO 8" (OR GREATER) = 5.25" AVERAGE THICKNESS =
31.525 (R-VALUE) = 0.031721 (U-VALUE). CALCULATION INCLUDES 1/2" COVER BOARD (R-VALUE=0.55).
C402.2.1.2 MINIMUM THICKNESS, LOWEST POINT.
THE MINIMUM THICKNESS OF ABOVE-DECK ROOF INSULATION AT ITS LOWEST POINT, GUTTER EDGE, ROOF DRAIN OR SCUPPER, SHALL BE NOT LESS THAN 1 INCH (25 MM). PROJECT: MINIMUM GUTTER EDGE = 1"
VEBC 2021
SECTION 602
ALTERATION—LEVEL 1
602.1 SCOPE.
LEVEL 1 ALTERATIONS AS DESCRIBED IN SECTION 601.2.1 SHALL COMPLY WITH THE REQUIREMENTS OF THIS SECTION.
602.3.2.1 REROOFING.
MATERIALS AND METHODS OF APPLICATION USED FOR RECOVERING OR REPLACING AN EXISTING ROOF COVERING SHALL COMPLY WITH CHAPTER 15 OF THE VCC, EXCEPT AS MODIFIED BY SECTION 302.1 AND THIS SECTION.
EXCEPTIONS:
-ROOF REPLACEMENT OR ROOF RECOVER OF EXISTING LOW-SLOPE ROOF COVERINGS SHALL NOT BE REQUIRED TO MEET THE MINIMUM DESIGN SLOPE REQUIREMENT OF ONE-QUARTER UNIT VERTICAL IN 12 UNITS HORIZONTAL (2-PERCENT SLOPE) IN SECTION 1507 OF THE VCC
FOR ROOFS THAT PROVIDE POSITIVE ROOF DRAINAGE.
-RECOVERING OR REPLACING AN EXISTING ROOF COVERING SHALL NOT BE REQUIRED TO MEET THE REQUIREMENT OF SECONDARY (EMERGENCY OVERFLOW) DRAINS OR SCUPPERS IN SECTION 1502 OF THE VCC FOR ROOFS THAT PROVIDE POSITIVE ROOF DRAINAGE. FOR THE PURPOSES OF THIS EXCEPTION, EXISTING SECONDARY DRAINAGE OR SCUPPER SYSTEMS REQUIRED IN ACCORDANCE WITH THE VCC SHALL NOT BE REMOVED UNLESS THEY ARE REPLACED BY SECONDARY DRAINS OR SCUPPERS DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTION
1502 OF THE VCC.
-WHERE THE EXISTING ROOF ASSEMBLY INCLUDES AN ICE BARRIER MEMBRANE THAT IS ADHERED TO THE ROOF DECK, THE EXISTING ICE BARRIER MEMBRANE SHALL BE PERMITTED TO REMAIN IN PLACE AND COVERED WITH AN ADDITIONAL LAYER OF ICE BARRIER MEMBRANE IN
ACCORDANCE WITH SECTION 1507 OF THE VCC.
602.3.2.1.1 ROOF RECOVER PERMITTED.
THE INSTALLATION OF A NEW ROOF COVERING OVER AN EXISTING ROOF COVERING SHALL BE PERMITTED WHERE ANY OF THE FOLLOWING CONDITIONS OCCUR:
WHERE THE NEW ROOF COVERING IS INSTALLED IN ACCORDANCE WITH THE ROOF COVERING MANUFACTURER’S APPROVED INSTRUCTIONS. PROJECT: EXISTING CONDITION PREVIOUSLY HAS A ROOF RECOVER INSTALLED.
602.3.2.1.2 ROOF RECOVER NOT PERMITTED.
A ROOF RECOVER SHALL NOT BE PERMITTED WHERE ANY OF THE FOLLOWING CONDITIONS OCCUR:
WHERE THE EXISTING ROOF OR ROOF COVERING IS WATER SOAKED OR HAS DETERIORATED TO THE POINT THAT THE EXISTING ROOF OR ROOF COVERING IS NOT ADEQUATE AS A BASE FOR ADDITIONAL ROOFING.
WHERE THE EXISTING ROOF HAS TWO OR MORE APPLICATIONS OF ANY TYPE OF ROOF COVERING. PROJECT: NO ROOF RECOVERING TO OCCUR.
602.3.2.1.3 REINSTALLATION OF MATERIALS.
EXISTING VENT FLASHING, METAL EDGINGS, DRAIN OUTLETS, COLLARS, AND METAL COUNTER-FLASHINGS SHALL NOT BE REINSTALLED WHERE RUSTED, DAMAGED, OR DETERIORATED. AGGREGATE SURFACING MATERIALS SHALL NOT BE REINSTALLED. METAL FLASHING TO WHICH
BITUMINOUS MATERIALS ARE TO BE ADHERED SHALL BE PRIMED PRIOR TO INSTALLATION.
/1
/2
A
M E
N D
M E
N T
AVERAGE R-VALUE TAPERED INSULATION CALCULATIONS
ROOF REPLACEMENT CODE SUMMARY:
Lic. No. 013830
JASON A. MILLER
L
O C
I
NI
G
RI
VF
OHTAE
W
N O M
M
A
A HCRDE
C
ERT
I
IF
CET
T
I
8:53:32
AM
06/18/2026 Lic. No. 0401013830
APPLICABLE CODES AND STANDARDS
• VIRGINIA CONSTRUCTION CODE (VCC) (2021)
• VIRGINIA STATEWIDE FIRE PREVENTION CODE (2021)
• VIRGINIA EXISTING BUILDING CODE (2021)
• NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS (2019)
• NFPA 70, NATIONAL ELECTRIC CODE (2020)
• NFPA 72, NATIONAL FIE ALARM AND SIGNALING CODE (2019)
• NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION AND DEMOLITION
OPERATIONS
SUMMARY OF FIRE PROTECTION FEATURES
PROJECT INCLUDES THE FOLLOWING FIRE PROTECTION FEATURES:
• AUTOMATIC FIRE SPRINKLER SYSTEMS
• FIRE ALARM SYSTEMS
• FIRE-RESISTANCE RATED CONSTRUCTION
• EMERGENCY LIGHTING AND EXIT SIGNS
• PORTABLE FIRE EXTINGUISHERS
TYPE OF CONSTRUCTION
THE BUILDING IS TYPE II-B CONSTRUCTION IN ACCORDANCE WITH CHAPTER 6 OF THE
VCC. TYPE II CONSTRUCTION HAS NON-COMBUSTIBLE, NON-RATED BUILDING
ELEMENTS AS LISTED IN TABLE 601 OF THE VCC.
BUILDING AREA: TYPE II-B (NON-COMBUSTIBLE, NON-RATED)
FIRE-RESISTANCE RATED BUILDING COMPONENTS
VCC CHAPTER 6
COMPONENT REQUIRED PROVIDED
PRIMARY STRUCTURAL FRAME 0-HOURS 0-HOURS
EXTERIOR BEARING WALLS 0-HOURS 0-HOURS
INTERIOR BEARING WALLS 0-HOURS 0-HOURS
EXTERIOR NONBEARING WALLS AND PARTITIONS 0-HOURS (NOTE 1)
INTERIOR NONBEARING WALLS AND PARTITIONS 0-HOURS (NOTE 2)
FLOOR CONSTRUCTION AND SECONDARY MEMBERS 0-HOURS 0-HOURS
ROOF CONSTRUCTION AND SECONDARY MEMBERS 0-HOURS 0-HOURS
NOTE 1: SEE "BUILDING SEPARATION AND EXPOSURE PROTECTION" SECTION
NOTE 2: SEE "REQUIRED INTERIOR SEPARATION" SECTION
HEIGHT LIMITATIONS
THE SCOPE OF WORK FOR THIS PROJECT WILL NOT ALTER THE HEIGHT OF THE BUILDING. AFTER THE PROJECT THE BUILDING WILL REMAIN BELOW THE ALLOWABLE HEIGHT LIMITS FOR TYPE II-B
CONSTRUCTION OF A GROUP B OCCUPANCY.
BUILDING SEPARATION AND EXPOSURE PROTECTION
THE LOCATION OF THE EXISTING BUILDING IS NOT BEING ALTERED. THEREFORE, EVALUATION OF THE EXISTING BUILDING SEPARATION AND EXPOSURE PROTECTION IS NOT INCLUDED INDER THIS PROJECT
SCOPE OF WORK.
REQUIRED INTERIOR SEPARATIONS
VCC 509, NFPA 70 (NEC), BUILDING STANDARDS
COMPONENT REQUIRED RATING PROVIDED RATING
ELECTRICAL ROOM (EQUIP >112 1/2 KVA) 1-HOUR 1-HOUR
ELECTRICAL ROOM (EQUIP <112 1/2 KVA) SMOKE PARTITION (NR) SMOKE PARTITION (NR)
CORRIDORS 0-HOUR NOT RATED
NR= NON RATED
CLASSIFICATION OF OCCUPANCY
FACILITY IS CLASSIFIED AS A GROUP B OCCUPANCY AND INCLUDES ACCESSORY ASSEMBLY AND
STORAGE OCCUPANCIES.
AREA LIMITATIONS
TOTAL PROJECT AREA IS APPROXIMATELY 19,080 SQ.FT.
THE SCOPE OF WORK FOR THIS PROJECT WILL NOT ALTER THE AREA OF THE BUILDING. AFTER THE PROJECT THE BUILDING WILL REMAIN BELOW THE AREA LIMITS FOR TYPE II-B CONSTRUCTION OF A
GROUP B OCCUPANCY.
VERTICAL OPENINGS
THE SCOPE OF WORK OF THIS PROJECT WILL NOT ADD ANY ADDITIONAL VERTICAL OPENINGS TO THE
BUILDING.
APPROVED EQUIVALENCIES
NOT APPLICABLE - NO EQUIVALENCIES HAVE BEEN REQUESTED FOR THIS PROJECT.
INCIDENTAL USE AREAS
VCC 509
THERE ARE NO INCIDENTAL USE SPACES WITHIN THE PROJECT AREA REQUIRING SPECIAL PROTECTION UNDER VCC 509. REFER TO "REQUIRED INTERIOR SEPARATIONS" FOR PARTITION REQUIREMENTS.
MEANS OF EGRESS ILLUMINATION
VCC CHAPTER 10
MEANS OF EGRESS ILLUMINATION IS REQUIRED. AUTOMATIC DIMMERS NOT PERMITTED.
SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATION.
EMERGENCY LIGHTING
VCC CHAPTER 10
EMERGENCY LIGHTING IS REQUIRED. SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATION.
MEANS OF EGRESS MARKING
VCC CHAPTER 10
ILLUMINATED EXIT SIGNAGE IS REQUIRED AT EXITS AND DIRECTIONAL EXIT SIGNAGE REQUIRED ALONG
THE PATH OF EGRESS TRAVEL. SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATION.
FIRE DEPARTMENT VEHICLE ACCESS
EXISTING FIRE DEPARTMENT VEHICLE ACCESS FOR THE BUILDING IS EXISTING TO REMAIN AND NOT
EVALUATED UNDER THIS PROJECT SCOPE WORK.
AN AUTOMATIC FIRE SUPPRESSION SYSTEM IS PROVIDED IN THE BUILDING.
AUTOMATIC FIRE SUPPRESSION SYSTEMS
PORTABLE FIRE EXTINGUISHERS
VCC 906
PORTABLE FIRE EXTINGUISHERS ARE NOT REQUIRED TO BE PROVIDED AND INSTALLED IN ACCORDANCE
WITH VCC 906.1 EXCEPTION 1.
A FIRE DETECTION AND ALARM SYSTEM IS REQUIRED TO BE PROVIDED IN THE BUILDING. A NEW FIRE DETECTION AND ALARM SYSTEM SHALL BE INSTALLED ON THE FIRST FLOOR ONLY DURING THIS SCOPE OF WORK. THE FIRE ALARM SYSTEM SHALL BE CAPABLE OF EXTENDING TO THE SECOND FLOOR DURING
FUTURE RENOVATION.
FIRE DETECTION AND ALARM SYSTEM
FIRE HYDRANTS AND FIRE SUPPRESSION SYSTEMS ARE SUPPLIED BY THE EXISTING MUNICIPAL
UNDERGROUND WATER DISTRIBUTION SYSTEM.
WATER SUPPLY
FIRE HYDRANTS
EXISTING FIRE HYDRANTS SERVING THE BUILDING ARE TO REMAIN AND NOT EVALUATED UNDER THIS
PROJECT SCOPE OF WORK.
INTERIOR FINISH REQUIREMENTS
VCC CHAPTER 8 TABLE 803.13
INTERIOR FINISH SHALL COMPLY WITH FOLLOWING:
COMPONENT INTERIOR FINISH FLOOR FINISH
EXITS A OR B I OR II
EXIT ACCESS CORRIDORS A, B OR C I OR II
OTHER SPACES A, B, OR C NOT APPLICABLE
FOR INTERIOR FINISH:
CLASSIFICATION FLAME SPREAD INDEX SMOKE DEVELOPMENT INDEX
CLASS A 0 - 25 0 - 450
CLASS B 26 - 75 0 - 450
CLASS C 76 - 200 0 - 450
FOR FLOOR FINISH:
CLASSIFICATION CRITICAL RADIANT FLUX
CLASS I >0.45 W/SQ.CM
CLASS II 0.22 - 0.45 W/SQ.CM
VCC CHAPTER 10 TABLE 1004.5
USE OCCUPANT LOAD FACTOR (OLF)
ASSEMBLY (LESS CONCENTRATED) 15 SQ.FT PER PERSON (NET)
BUSINESS (LESS CONCENTRATED) 150 SQ.FT PER PERSON (GROSS)
STORAGE (GENERAL) 500 SQ.FT PER PERSON (GROSS)
OCCUPANT LOAD
NUMBER OF EXITS
VCC CHAPTER 10 TABLE 1006.3.3
MINIMUM NUMBER OF EXITS ARE REQUIRED FOR EACH STORY AS FOLLOWS:
• FOR AN OCCUPANT LOAD OF LESS THAN 500 PERSONS - NOT LESS THAN 2 EXITS
STORY OCCUPANT LOAD EXITS REQUIRED EXITS PROVIDED
PROJECT AREA LESS THAN 500 2 3
REQUIRED SEPARATION OF EXITS
VCC CHAPTER 10 SECTION 1007.1.1 EXCEPTION 2
WHERE TWO EXITS, EXIT ACCESS DOORWAYS, EXIT ACCESS STAIRWAYS OR RAMPS, OR ANY
COMBINATION THEREOF, ARE REQUIRED FROM ANY PORTION OF THE EXIT ACCESS, THEY ARE
REQUIRED TO BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN ONE-FOURTH OF THE LENGTH
OF
THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED
IN A STRAIGHT LINE BETWEEN THEM.
EXIT CAPACITY AND EXIT WIDTH
VCC CHAPTER 10
COMPONENT EGRESS CAPACITY FACTOR
STAIRWAYS 0.2 INCHES PER PERSON
LEVEL COMPONENTS AND RAMPS 0.15 INCHES PER PERSON
REQUIRED EXIT WIDTH FOR THE MEANS OF EGRESS:
• MINIMUM CLEAR WIDTH OF DOORS IS 32 INCHES
• MINIMUM WIDTH OF STAIRS IS 44 INCHES
• MINIMUM WIDTH CORRIDORS IS 44 INCHES
EGRESS ARRANGEMENT
VCC CHAPTER 10 TABLE 1017.2, TABLE 1006.2.1 AND SECTION 1020.5 EXCEPTION 2
USE TRAVEL DISTANCE COMMON PATH DEAD END CORRIDOR
ASSEMBLY (<50 PERSONS) 250 FT (MAX) 75 FT (MAX) 20 FT (MAX)
BUSINESS 300 FT (MAX) 100 FT (MAX) 50 FT (MAX)
STORAGE 400 FT (MAX) 100 FT (MAX) 50 FT (MAX)
PLUMBING FIXTURE COUNT
WATER CLOSETS:
1 PER 25 FOR THE FIRST 50 AND 1 PER 50 FOR THE REMAINDER EXCEEDING 50
243 OCCUPANTS / 2 = 122 MEN & 122 WOMEN
MEN; 4 REQUIRED, 8 UNISEX RESTROOMS PROVIDED
WOMEN; 4 REQUIRED; 8 UNISEX RESTROOMS PROVIDED
LAVATORIES:
1 PER 40 FOR THE FIRST 80 AND 1 PER 80 FOR THE REMAINDER EXCEEDING 80
MEN; 3 REQUIRED; 8 UNISEX RESTROOMS PROVIDED
WOMEN; 3 REQUIRED; 8 UNISEX RESTROOMS PROVIDED
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
1 2 3 4 5 6
A
B
C
D
E
SHEET NAME:
PROJECT NO:
DATE ISSUED:
SHEET NO:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
IS
S
U A
N C
E S
C H
E D
U
M B
S
C R
IP
T ut od es k D oc s:
//S uf fo lk
V A
C ity P ro je ct s
H U
B _B
0_
R
/G od w in
-V irg in ia n P ilo t_
R en o_ A
R C
H _R
.r vt
7/
/2
:0 8:
A
M
CODE SUMMARY
LS001
E. GASCHO
J. ZIMMERMAN
K. BARKER
06/17/2026
G O
D W
IN
V
IR
G
IN
IA
N
P
IL
O T
B U
IL
D
IN
G
C
IT
Y O
F S
U F
F O
LK
, V
A
N . M
A
IN
S T
. S U
F F
O
LK
V A
R E
N O
V A
T
IO
N
/1
/2
A
M E
N D
M E
N T
OCCUPANT LOAD - FIRST FLOOR
ROOM NO. ROOM NAME SPACE USE & LF
AREA
(APPROX.)
OCCUPANCY
LOAD FACTOR
OCCUPANT
LOAD
115 STORAGE ACCESSORY STORAGE/MECH ROOMS 103 SF 300 1
151 STORAGE ACCESSORY STORAGE/MECH ROOMS 76 SF 300 1
154 JANITOR ACCESSORY STORAGE/MECH ROOMS 51 SF 300 1
160 SPRINKLER ACCESSORY STORAGE/MECH ROOMS 48 SF 300 1
162 STORAGE ACCESSORY STORAGE/MECH ROOMS 57 SF 300 1
163 STORAGE ACCESSORY STORAGE/MECH ROOMS 62 SF 300 1
164 COMM/DATA /ELEC ACCESSORY STORAGE/MECH ROOMS 113 SF 300 1
165 STORAGE ACCESSORY STORAGE/MECH ROOMS 137 SF 300 1
171 ELEC ACCESSORY STORAGE/MECH ROOMS 264 SF 300 1
172 ELEC ACCESSORY STORAGE/MECH ROOMS 99 SF 300 1
174 STORAGE ACCESSORY STORAGE/MECH ROOMS 53 SF 300 1
177 STORAGE ACCESSORY STORAGE/MECH ROOMS 55 SF 300 1
104 VICTIM WITNESS CONFERENCE ASSEMBLY (LESS CONCENTRATED) 293 SF 15 20
108 CONFERENCE ASSEMBLY (LESS CONCENTRATED) 137 SF 15 10
129 CONFERENCE ASSEMBLY (LESS CONCENTRATED) 190 SF 15 13
139 CONFERENCE ASSEMBLY (LESS CONCENTRATED) 157 SF 15 11
144 BREAK ROOM ASSEMBLY (LESS CONCENTRATED) 401 SF 15 27
148 BREAK ASSEMBLY (LESS CONCENTRATED) 198 SF 15 14
150 CONFERENCE ASSEMBLY (LESS CONCENTRATED) 397 SF 15 27
101 VESTIBULE BUSINESS 197 SF 150 2
102 LOBBY BUSINESS 368 SF 150 3
105 COPY AREA BUSINESS 243 SF 150 2
109 VICTIM WITNESS DIRECTOR BUSINESS 137 SF 150 1
112 CORRIDOR BUSINESS 274 SF 150 2
113 VICTIM WITNESS SUITE BUSINESS 408 SF 150 3
114 INVESTIGATOR SUITE BUSINESS 387 SF 150 3
116 CHIEF INVESTIGATOR BUSINESS 143 SF 150 1
117 ASSISTANT CW ATTORNEY BUSINESS 131 SF 150 1
118 ASSISTANT CW ATTORNEY BUSINESS 131 SF 150 1
119 ASSISTANT CW ATTORNEY BUSINESS 131 SF 150 1
120 ASSISTANT CW ATTORNEY BUSINESS 131 SF 150 1
121 ASSISTANT CW ATTORNEY BUSINESS 131 SF 150 1
122 DEPUTY CA BUSINESS 158 SF 150 2
123 DEPUTY CA BUSINESS 158 SF 150 2
124 DEPUTY CA BUSINESS 158 SF 150 2
125 CHIEF DEPUTY CA BUSINESS 157 SF 150 2
128 STAFF ENTRY BUSINESS 78 SF 150 1
130 HEAD CW ATTORNEY OFFICE BUSINESS 266 SF 150 2
131 CHIEF ADMIN MANAGER BUSINESS 133 SF 150 1
132 SUPERVISOR BUSINESS 110 SF 150 1
133 ASSISTANT CW ATTORNY BUSINESS 133 SF 150 1
134 ASSISTANT CW ATTORNEY BUSINESS 133 SF 150 1
135 ASISSTANT CW ATTORNEY BUSINESS 133 SF 150 1
136 COMMONWEALTH ATTORNEY OPEN OFFICE BUSINESS 1820 SF 150 13
137 ASSISTANT CW ATTORNEY BUSINESS 137 SF 150 1
138 CEASE FIRE CA BUSINESS 137 SF 150 1
140 ASSISTANT CW ATTORNEY BUSINESS 144 SF 150 1
141 ASSISTANT CW ATTORNEY BUSINESS 142 SF 150 1
142 ASSITANT CW ATTORNEY BUSINESS 142 SF 150 1
143 CORRIDOR BUSINESS 643 SF 150 5
145 COPY BUSINESS 118 SF 150 1
146 ASSISTANT CW ATTORNEY BUSINESS 158 SF 150 2
147 CORRIDOR BUSINESS 405 SF 150 3
155 CHIEF ANIMAL CONTROL OFFICER BUSINESS 109 SF 150 1
156 SARGEANT BUSINESS 109 SF 150 1
157 SARGEANT BUSINESS 109 SF 150 1
158 HEAD POLICE OFFICER - TRAINING COORD. BUSINESS 108 SF 150 1
159 POLICE DEPT. OPEN OFFICE BUSINESS 1688 SF 150 12
168 CORRIDOR BUSINESS 482 SF 150 4
170 POLICE WELLNESS BUSINESS 1559 SF 150 11
175 CORRIDOR BUSINESS 578 SF 150 4
176 MOTHERS ROOM BUSINESS 76 SF 150 1
166 WOMENS SHOWER LOCKER ROOMS (PER AREA) 137 SF 50 3
167 MENS SHOWER LOCKER ROOMS (PER AREA) 140 SF 50 3
44 SHAFT NO OCCUPANT LOAD 16 SF 0
103 CLOSET NO OCCUPANT LOAD 9 SF 0
106 STAIR 1 NO OCCUPANT LOAD 143 SF 0
107 STOR NO OCCUPANT LOAD 22 SF 0
110 TLT NO OCCUPANT LOAD 64 SF 0
111 ADA TLT NO OCCUPANT LOAD 73 SF 0
126 ADA TLT NO OCCUPANT LOAD 73 SF 0
127 TLT NO OCCUPANT LOAD 70 SF 0
149 STORAGE NO OCCUPANT LOAD 26 SF 0
152 ADA TLT NO OCCUPANT LOAD 57 SF 0
153 TLT NO OCCUPANT LOAD 46 SF 0
161 ELEV NO OCCUPANT LOAD 51 SF 0
169 ADA TLT NO OCCUPANT LOAD 56 SF 0
173 STAIR 3 NO OCCUPANT LOAD 242 SF 0
178 STAIR 2 NO OCCUPANT LOAD 50 SF 0
TOTAL 243
Lic. No. 013830
JASON A. MILLER
L
O C
I
NI
G
RI
VF
OHTAE
W
N O M
M
A
A HCRDE
C
ERT
I
IF
CET
T
I
8:53:32
AM
06/18/2026
UP
SARGEANT
SARGEANT
HEAD POLICE
OFFICER - TRAINING
COORD.
VESTIBULE
LOBBY
VICTIM WITNESS
CONFERENCE
STAIR 1
STOR
CONFERENCE
VICTIM WITNESS
DIRECTOR
TLT
ASSISTANT CW
ATTORNEY
ASSISTANT CW
ATTORNEY
ASSISTANT CW
ATTORNEY
ASSISTANT CW
ATTORNEY
ASSISTANT CW
ATTORNEY
DEPUTY CA
DEPUTY CA
DEPUTY CA
CHIEF DEPUTY CA
ADA TLT
TLT
STAFF
ENTRY
CONFERENCE
HEAD CW ATTORNEY
OFFICE
130 131
CHIEF
ADMIN
MANAGER
ASISSTANT CW
ATTORNEY
SUPERVISOR
ASSISTANT CW
ATTORNY
ASSISTANT CW
ATTORNEY
ASSISTANT CW
ATTORNEY
ASSISTANT CW
ATTORNEY
ASSISTANT CW
ATTORNEY
CEASE FIRE CA
STORAGE
CHIEF
INVESTIGATOR
INVESTIGATOR
SUITE
CORRIDOR
CONFERENCE
BREAK ROOM
ASSITANT CW
ATTORNEY
POLICE
WELLNESS
ELEC
ELEC
STORAGE
STAIR 3
173 167
MENS
SHOWER
WOMENS
SHOWER
CORRIDOR
STORAGE
COMM/DATA
/ELEC
STORAGE
STORAGE
ELEV
CHIEF ANIMAL
CONTROL OFFICER
JANITOR
TLT
ADA TLT
STORAGE
POLICE DEPT. OPEN
OFFICE
BREAK
SPRINKLER
VICTIM WITNESS
SUITE
COMMONWEALTH
ATTORNEY OPEN
OFFICE
ADA TLT
CLOSET
CL
EX173
CONFERENCE
ASSISTANT
CW
ATTORNEY
COPY
STORAGE
CORRIDOR
CORRIDOR
136'
TD-3
170B
COPY
AREA
MOTHERS
ROOM 177
STORAGE
ADA TLT
CORRIDOR
80'
TD-1
148'
TD-2
SHAFT
106B
1-HOUR EXIT ENCLOSURE
• 60-MIN RATED OPENING PROTECTIVES
(DOORS AND WINDOWS)
• DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
• 1-HOUR RATED FIRESTOPPING FOR
PENETRATIONS PER UL LISTED METHOD
1-HOUR FIRE BARRIER
• 45-MIN RATED OPENING PROTECTIVES
(DOORS AND WINDOWS)
• DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
• FIRE AND SMOKE DAMPERS REQUIRED FOR
DUCTED SYSTEMS
• 1-HOUR RATED FIRESTOPPING FOR
PENETRATIONS PER UL LISTED METHOD
XXX EXIT IDENTIFIER
TRAVEL DISTANCE (TD)
COMMON PATH OF TRAVEL (CPT)
DEAD END (DE) CORRIDOR
SMOKE PARTITION
• DOORS TO RESIST THE PASSAGE OF
SMOKE; SMOKE SEALS NOT REQUIRED
• DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
• SMOKE DAMPERS REQUIRED FOR AIR
TRANSFER OPENINGS
EXIT
IDENTIFIER
DOOR
CLEAR WIDTH
(IN)
DOOR CAPACITY
FACTOR
(IN/PERSON)
DOOR
CAPACITY
(PERSONS)
STAIR
WIDTH
(IN)
STAIR
CAP.FACTOR
(IN/PERSON)
STAIR
CAPACITY
(PERSONS)
LIMITING
CAPACITY
(PERSONS)
ACTUAL
USE
(PERSONS)
EXIT SUMMARY - FIRST FLOOR
106B
TOTAL
226 N/A N/A 226N/A0.15
453 N/A N/A 453N/A0.1568
226 N/A N/A 226N/A0.1534
170B
EX173
373 N/A N/A 373N/A0.15
453 N/A N/A 453N/A0.1568
226 N/A N/A 226N/A0.1534
175 226 N/A N/A 226N/A0.1534 46
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
1 2 3 4 5 6
A
B
C
D
E
SHEET NAME:
PROJECT NO:
DATE ISSUED:
SHEET NO:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
IS
S
U A
N C
E S
C H
E D
U
M B
S
C R
IP
T ut od es k D oc s:
//S uf fo lk
V A
C ity P ro je ct s
H U
B _B
0_
R
/G od w in
-V irg in ia n P ilo t_
R en o_ A
R C
H _R
.r vt
7/
/2
:0 8:
A
M
LIFE SAFETY PLAN
LS101
E. GASCHO
J. ZIMMERMAN
K. BARKER
06/17/2026
G O
D W
IN
V
IR
G
IN
IA
N
P
IL
O T
B U
IL
D
IN
G
C
IT
Y O
F S
U F
F O
LK
, V
A
N . M
A
IN
S T
. S U
F F
O
LK
V A
R E
N O
V A
T
IO
N
1/8" = 1'-0" B1
OVERALL LIFE SAFETY PLAN
LEGEND:SHEET KEYNOTES:
PLAN NORTH
24'16'8'4'0
1/8"=1'-0"
GRAPHIC SCALE
SCHEDULES:
EGRESS ARRANGEMENT - FIRST FLOOR
MARK LENGTH FROM ROOM TO ROOM
TD-1 80' STORAGE 177 POLICE WELLNESS 170
TD-2 148' BREAK ROOM 144 STAIR 1 106
TD-3 136' CONFERENCE 150 CORRIDOR 175
/1
/2
A
M E
N D
M E
N T
Lic. No. 013830
JASON A. MILLER
L
O C
I
NI
G
RI
VF
OHTAE
W
N O M
M
A
A HCRDE
C
ERT
I
IF
CET
T
I
8:53:32
AM
06/18/2026
E E
E
E
E
E
EE
E
E E E
E
EE
E
LIGHT
WELLCHIMNEY
FLUE
UNIT #21
UNIT #22
UNIT #23
UNIT #27
UNIT #26
UNIT #25
(E)EF
(E)EF
(E)RD
(E)RD (E)RD (E)RD
(E)RD
(E)S/CH
(E)S
(E)S
(E)RD
(E)RD
(E)S/CH
SIM.
TYP. AT CAPPED CURBS
(E)VTR
E
(E)S/CH
HIGH
1,2
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
4454 IDEA CENTER BOULEVARD
DAYTON, OH 45430-1500
937.461.5660
1 2 3 4 5 6 7
A
B
C
D
E
IS
SU
AN
CE
S
CH
ED
UL
E
SHEET NAME:
PROJECT NO:
DATE ISSUED:
NU
MB
ER
AT
ES
CR
IP
TI
ON
SHEET NO:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
HNA
HNA
WSP
10015069.02 07/08/2026
GO
DW
IN
- V
IRG
INI
AN
PI
LO
T B
UIL
DIN
G
CI
TY
O
F
SU
FF
OL
K, V
A
7 N
. M
AI
N
ST
. S
UF
FO
LK
V A
RE
NO
VA
TIO
N
HUGH N. ADCOCK, JR.
Lic. No. 015231
07/08/2026
ROOF PLAN -
HAZMAT REMOVAL
H-103
SCALE: 1/8" = 1'-0"
ROOF PLAN - HAZMAT REMOVAL
SHEET KEYNOTESGENERAL SHEET NOTES
1. SEE H-001 FOR HAZARDOUS MATERIAL GENERAL NOTES.
2. CONTRACTOR MUST COORDINATE ALL ASPECTS OF THE WORK WITH OTHER
TRADES. SEE ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING, AND
ELECTRICAL DEMOLITION DRAWINGS.
3. SEE ARCHITECTURAL DRAWINGS FOR LEGEND AND ABBREVIATIONS.
(H-001 - H-103) (H-103)XX
1. REMOVE EXTERIOR LIGHT WELL ACM WINDOW GLAZING COMPOUND ON THE
ROOF.
2. REMOVE ACM BLACK SEALANT AND SILVER PAINT ON BASE FLASHING ON THE
ROOF.
3. REMOVE ACM PARAPET FLASHING FROM ROOF PARAPET WALLS.
A6 H-103
PHOTOGRAPH LOCATION
KEY TO SYMBOLS (H-001 - H-103)
X
XXX
A5 H-103
H-103SCALE:
REFERENCE PHOTO - NOTE 1A5 NO SCALE H-103SCALE:
REFERENCE PHOTO - NOTE 2A6 NO SCALE
ACM PARAPET WALL
FLASHING BEHIND
SINGLE PLY ROOFING
REFERENCE PHOTOGRAPH NOTES
1. PARAPET WALL FLASHING FOUND BEHIND SINGLE PLY ROOFING. THE
PARAPET WALL FLASHING AND SILVER COATING APPLIED TO THE FLASHING IS
ACM.
2. VIEW OF BUILT-UP ROOFING FOUND BENEATH THE SINGLE PLY ROOFING
SYSTEM.
(H-103)
BUILDING SECTION
DETAIL/ENLARGED PLAN
EXTERIOR ELEVATIONS
DRAWING TITLE
P
G Q
R
S
H
I
J
A
B
C
SYMBOLS
T
U
V
W
K
L
M
N
O
D
E
F
DRAWING SYMBOLS
REFERENCE SYMBOLSABBREVIATIONS MATERIAL SYMBOLS
DRAWING REFERENCE NUMBER
DRAWING SHEET NUMBER
END OF SECTION
DRAWING SHEET NUMBER
DRAWING REFERENCE NUMBER
DRAWING REFERENCE NUMBER
DRAWING SHEET NUMBER
SCALE OF DRAWING
DRAWING TITLE
DRAWING REFERENCE NUMBER
EH ELECTRIC HEATER
UNLESS NOTED OTHERWISEUNO
OPP OPPOSITE
PLATE
PLASTER
PRE-ENGINEERED METAL BUILDING
GAUGE
GROUND
GALVANIZED
G
GA
GALV
PL
PLAS
PEMB
QUARRY TILE
PAINT
PARTITION
POLYVINYL CHLORIDE
PORCELAIN
RISERS
RUBBER
RECESSED
REFERENCE
ROOF DRAIN
RADIUS
RESILIENT BASE
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
REFLECTED CEILING PLAN
SOUTH
SCHEDULE
REQUIRED
ROOM
RESILIENT
RESISTANT
ROUGH OPENING
RETAINING
SQUARE
STEEL
STANDARD
STAINLESS STEEL
STUCCO
SHEET
SIMILAR
SECTION
SEALANT
SPECIFICATION
SOLID CORE WOOD
REINFORCED
GLASS
GALVANIZED IRON
GENERAL
GYPSUM
GROUT
GYPSUM BOARD
GYPSUM PLASTER
GLAZED TILE
GLASS BLOCK
GROUND FAULT CIRCUIT INTERRUPT
HEAD
HOLLOW METAL
HARDWARE
HARDWOOD
HOLLOW CORE
GI
GL
GFCI
GEN
GT
GT
GYP BD
GYP PLAS
GYP
GL BLK
HD
HC
HM
HDW
HDWD
HEIGHT
HORIZONTAL
INCH
INSULATION
INSIDE DIAMETER
INVERT
JANITOR
JOINT
JUNCTION BOX
INTERIOR
HT
HORIZ
IN
ID
INSUL
INV
JT
JAN
J-BOX
INT
HANDRAILHNDRL
SQ
SST
STL
STD
STUC
R
SCW
SHT
SIM
SECT
SPEC
SLNT
S
SCHED
REQD
RES
RET
RESIL
RO
RM
RD
REF
REC
REINF
RBR
PSI
QT
R
PT
PVC
PTN
PSF
PORC
RB
RCP
PLYWD
GENERAL CONTRACTOR
PLYWOOD
GC
AND
AT
ANGLE
AFF
ADJ
ACT
ACPL
ACOUS
BOARD
ALT
AHR
BD
ATTEN
BLDG
ALUM
APPROX
AFG
BEAM
BRICK
BRG
BOT
BM
BRK
CAB
CB
CEM
BSMT
CG
CJ
CM
CLG
CER
CO
CMU
CONC
COL
CONSTR
CEM PLAS
BLK BLOCK
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CLEAN OUT
CONSTRUCTION
ATTENUATION
CEMENT PLASTER
CERAMIC
CEILING
CERAMIC MOSAIC
CORNER GUARD
CONTROL JOINT
CEMENT
CATCH BASIN
CABINET
BEARING
BOTTOM
BASEMENT
BUILDING
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ANCHOR
ALUMINUM
ALTERNATE
APPROXIMATELY
ACOUSTICAL CEILING TILE
ACOUSTICAL
ACOUSTICAL PLASTER
ADJUSTABLE
CHANNEL
DIAMETER
CENTER LINE
TREADS
TOP AND BOTTOM
TONGUE AND GROOVE
SUSPENDED
SHEET VINYL
TOP OF CONCRETE
TOP OF MASONRY
TOP OF STEEL
TOP OF WALL
THROUGH
TYPICAL
TERRAZZO
TELEPHONE
VINYL WALL COVERING
VITRIFIED CLAY PIPE
VERTICAL
URINAL
WOOD PANELING
WEST
WOOD
WITH
WIDE FLANGE
WATER CLOSET
VINYL COMPOSITION TILE
T
KITCHEN
KICKPLATE
LAMINATE
LOUVER
LIGHT WEIGHT
LINOLEUM
LAVATORY
KPL
KIT
LAM
LT WT
LVR
LINO
LAV
MECHANICAL
MAN HOLE
MOISTURE GYPSUM BOARD
MACHINE
MAXIMUM
METAL
MULLION
MOISTURE RESISTANT
MINIMUM
MASONRY OPENING
NORTH
NOT IN CONTRACT
NOMINAL
NOT TO SCALE
MECH
MGYP BD
MH
MAX
MACH
MTL
MULL
MR
MO
MIN
N
NIC
NOM
NTS
WDP
WC
WF
WD
W/
W
VWC
VCP
VCT
VERT
UR
TOC
TOS
TOM
TYP
THRU
TOW
TEL
TER
T & G
T & B
SUSP
SV
WATERPROOF
WELDED WIRE FABRIC
OVERHEAD DOOR
OPENING
OPERABLE PARTITION
OVERHANG
OUTSIDE DIAMETEROD
OH
OHD
OP
OPNG
WP
WWF
WR
ON CENTER
WATER-RESISTANT
OC
DETAIL
CPT
CT
CR
DET
DIM
DIA
DBL
DIAG
DOOR
DOWN
EACH
EAST
DR
DS
DN
E
EA
DWG
DISP
EQUALEQ
EPT
EL
EXP
EXP
EW
EWC
ENAM
EXIST
EQUIP
ELEC
FINISH
FLOOR
FD
FLR
FIN
FH
FEC
FDTN
EXT
EJ
FLUOR FLUORESCENT
FLOOR DRAIN
FOUNDATION
FLAT HEAD
EXPOSED STRUCTURE
EXPANSION
EXTERIOR
ENAMEL
ELECTRIC WATER COOLER
EPOXY PAINT
EQUIPMENT
EXISTING
EACH WAY
ELEVATION
EXPANSION JOINT
ELECTRICAL
DOWNSPOUT
DRAWING
DIAGONAL
DIAMETER
DISPENSER
DIMENSION
CARPET
CERAMIC TILE
COLD ROLLED
DOUBLE
FIRE EXTINGUISHER CABINET
CONT CONTINUOUS
STRUCT STRUCTURAL
ACOUSTICAL PANELACP
ACCENT PAINTAPT
BOTTOM OF DECKBOD
GLAZED BLOCKG BLK
MIRR MIRROR
MB MARKER BOARD
PTD PAPER TOWEL DISPENSER
SC SEALED CONCRETE
TB TACK BOARD
TS TACK STRIP
TOILET TISSUE DIPENSERTTD
EIFS EXTERIOR INSULATION FINISH SYSTEM
WALL SECTION
END OF SECTION
DRAWING SHEET NUMBER
DRAWING REFERENCE NUMBER
INTERIOR ELEVATIONS
DRAWING REFERENCE NUMBER
DRAWING SHEET NUMBER
CTW CERAMIC TILE WAINSCOT
PRECAST CONCRETEPC
VINYL ENHANCED TILEVET
MANUFACTURERMFR
F Cont'd.
FIELD VERIFYFV
FOOTFT
FTG FOOTING
GROUT SOLIDGS
MB/MR MARKER BOARD/MAP RAIL
ELEV ELEVATION
TO FINISHED FACETFF
EDGE GUARDEG
BOTTOM OF METAL DECKBMD
GYPSUM BOARDGB
MOISTURE GYPSUM BOARDMGB
STAIR RUBBER BASESRB
SPECIALTY KITCHEN FLOORINGSKF
VENTED WALL BASEVWB
FRAME
FOOD SERVICE EQUIPMENT PROVIDER
FR
FSEP
F.PRG FIREPROOFING
STANDING SEAM METAL ROOFSSMR
A1
A1
FIRE RETARDANT TREATEDFRT
ACOUSTICAL PANELAP
CTB CERAMIC TILE BASE
GYPSUM WALL BOARDGWB
A-411
A-301
A1
A-311
A1
A-401
A-201
A1
SIM
SIM
A1
SCALE: 1/8" = 1'-0"
VIEW NAME
ELEVATION INDICATIONS
GLASS CONCRETE SIDING
MASONRY
WOOD
FINISHES
INSULATION
LOOSE OR
BATT
GLASS
SMALL SCALE
PLYWOOD
FINISH
RIGID
LARGE SCALE
ROUGH
METAL
METAL @ LARGE
SCALE
STONE
CAST STONE
CMU BRICK
CONCRETE
CONCRETE
EARTHWORK
EARTH OR
COMPACT FILL
LT. WEIGHT
CONCRETE
GRANULAR FILL
SPRAY FOAM
GLASS BLOCK
BLOCKING
MORTAR
ROCK
BRICK CMU SHINGLES
SHADED PORTION IS THE
SIDE CONSIDERED
ROOM NAME
KEY NOTE
REVISION
ROOM NUMBER
DATUM POINT
MATCH LINE
WINDOW TAG
DOOR TAG
GRAPHIC SYMBOLS
WORK POINT
COLUMN GRID LINES
ROOM SYMBOL
PARTITION TYPE
R.D.
MISCELLANEOUS SYMBOLS
F.D.
CHANGE IN ELEVATION
ROOF DRAIN
FLOOR DRAINA
STORAGE
P1
POCKET DOOR
BI-FOLD DOOR
DOUBLE ACTING DOOR
EXIST. DOOR TO REMAIN
NEW SINGLE DOOR
ACCORDION FOLDING DOORDOOR WITH 180 DEGREE SWING
DOOR WITH EMERGENCY RELEASE HARDWARE
EXIST. DOOR TO BE REMOVED
NEW PAIR OF DOORS
DOOR CONVENTIONS
EQUIPMENT TAG
XX-XX
BARN DOOR
POINT ELEVATION
W1
A-101
DISCIPLINE
G - GENERAL
C - CIVIL
L - LANDSCAPE
S - STRUCTURAL
A - ARCHITECTURAL
I - INTERIORS
F - FIRE PROTECTION
P - PLUMBING
M - MECHANICAL
E - ELECTRICAL
SHEET NUMBERING SYSTEM
SHEET TYPE DESIGNATOR
0 - GENERAL - SYMBOLS/LEGEND & NOTES
1 - PLANS
2 - BUILDING ELEVATIONS
3 - BUILDING SECTIONS & WALL SECTIONS
4 - LARGE SCALE VIEWS
5 - DETAILS
6 - SCHEDULES & DIAGRAMS
7 - USER DEFINED - FLOOR FINISH PLANS
8 - USER DEFINED - LIFE SAFETY PLANS
9- 3D REPRESENTATIONS
SHEET SEQUENCE NUMBER
01 THROUGH 99
DISCIPLINE DESIGNATOR
- (DASH) or D (DEMOLITION)
LC
GYPSUM BOARD
CEILING HT
0' - 0"
MASONRY UNITSMU
TOILET ACC. TAG
XX-XX
CW COMMONWEALTH
ROOF TOP UNITRTU
AHU AIR HANDLING UNIT
TOILETTLT
ARCHITECTURE ENGINEERING GEOSPATIAL│ │
4433 CORPORATION LANE
SUITE 125
VIRGINIA BEACH, VA 23462
800.414.1045
1 2 3 4 5 6
A
B
C
D
E
SHEET NAME:
PROJECT NO:
DATE ISSUED:
SHEET NO:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
IS
S
U A
N C
E S
C H
E D
U
M B
S
C R
IP
T ut od es k D oc s:
//S uf fo lk
V A
C ity P ro je ct s
H U
B _B
0_
R
/G od w in
-V irg in ia n P ilo t_
R en o_ A
R C
H _R
.r vt
7/
/2
:0 8:
A
M
SYMBOLS AND
ABBREVIATIONS
A-001
N. DUNLEVY
MIJAL / MILLER
K. BARKER
06/17/2026
G O
D W
IN
V
IR
G
IN
IA
N
P
IL
O T
B U
IL
D
IN
G
C
IT
Y O
F S
U F
F O
LK
, V
A
N . M
A
IN
S T
. S U
F F
O
LK
V A
R E
N O
V A
T
IO
N
/1
/2
A
M E
N D
M E
N T
Lic. No. 013830
JASON A. MILLER
L
O C
I
NI
G
RI
VF
OHTAE
W
N O M
M
A
A HCRDE
C
ERT
I
IF
CET
T
I
8:53:32
AM
06/18/2026
4SA
3-5/8" METAL STUD AT 16" OC WITH 5/8" GWB ON EACH SIDE WITH CONTINUOUS 3-1/2" SOUND
ATTENUATION BATTS. EXTEND PARTITION METAL STUD AND GWB TO DECK ABOVE.
5/ 8"
5/
8" 5/
8"
CEILING AS SCHEDULED
ONE LAYER 5/8"…