IFB_2200_BYS1051REBID_ATT_5_v1.docx
DOCX document 55 KB Posted
- Attached to
- Sodium Bisulfate
- Solicitation number
- IFB 2200 BYS1051REBID
- Issued by
- Texas
About this file
This is a Scope of Work submittal document for the City of Austin's Sodium Bisulfate contract (IFB 2200 BYS1051 REBID), which outlines the required information and documentation that bidders must provide in response to the solicitation. The contract involves the delivery of a 38% sodium bisulfite solution in 330-gallon intermediate bulk containers (totes) on an as-needed basis to Austin Water Waste Treatment Plants. Bidders must demonstrate their operational capacity and capability to fulfill this contract by providing specific information about their distribution infrastructure, product approvals, and relevant experience in the wastewater treatment industry.
The submittal requirements include identification of a primary distribution terminal located within 500 miles of Austin with dedicated storage volume, an alternate distribution terminal with dedicated storage capacity, current National Sanitation Foundation (NSF) approval documentation for the manufacturer or trucking company, a valid Federal Department of Transportation (USDOT) number for the shipping company, and three current references from municipal wastewater treatment facilities within Texas that currently utilize the bidder's dechlorination product. Each reference must include the facility name and address, contact person information, contact phone number, and details regarding the current application of the product.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| IFB_2200_BYS1051REBID_ADD_2_v1.pdf | ||
| IFB_2200_BYS1051REBID_ATT_7_v1.docx | DOCX document | |
| IFB_2200_BYS1051REBID_ATT_9_v1.docx | DOCX document | |
| IFB_2200_BYS1051REBID_ATT_3_v1.docx | DOCX document | |
| IFB_2200_BYS1051REBID_ATT_1_v1.docx | DOCX document | |
| IFB_2200_BYS1051REBID_ATT_6_v1.docx | DOCX document | |
| IFB_2200_BYS1051REBID_ATT_2_v1.pdf | ||
| IFB_2200_BYS1051REBID_ATT_8_v1.docx | DOCX document | |
| IFB_2200_BYS1051REBID_PAC1_v1.pdf | ||
| IFB_2200_BYS1051REBID_ADD_1_v1.pdf | ||
| IFB_2200_BYS1051REBID_ATT_4_v1.xlsx | XLSX spreadsheet | |
| IFB_2200_BYS1051REBID_ATT_10_v1.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUBMITTAL – Scope of Work, Response
SUBMITTAL – Scope of Work, Response
1. Provide address of the primary distribution terminal (within five hundred (500) miles of the City of Austin) and the storage volume that will be dedicated to fulfilling the requirements of this Contract (see Scope of Work, Section 4.1.3.C and 4.1.3.D).
2. Provide address of the alternate distribution terminal and the storage volume that will be dedicated to fulfilling the requirements of this Contract (see Scope of Work, Section 4.1.3.C and 4.1.3.D).
3. Provide proof of National Sanitation Foundation (NSF) approval of manufacturer or trucking company (see Scope of Work Section 4.1.3.E).
4. Provide a current Federal Department of Transportation (USDOT) number of the shipping company (See Scope of Work Section 1.1.3.G).
5. Provide three (3) current municipal wastewater references within the State of Texas that utilize the product they offer to dechlorinate their wastewater treatment plant. Reference shall include the name and address of the Facility, contact person, contact phone number, and the current application of the product.
Provide on SUBMITTAL-Offeror References-REQUIRED.
SUBMITTAL – Scope of Work, Response Pg. 1 image1.png
File details come from the government source that posted it. Updated .