Inspection Checklist
View the file
Other files for this federal contract opportunity
Show all 28
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Please Print Legibly:
Serial No. :_______________________ Facility:_______________________ Inspector:_______________________ Date:_________________ ____
13.
1 Bedroom
2 Bedroom
3 Bedroom
19.
20.
21.
22.
Axles include grease fitting that are secured from environmental conditions when not being accessed during maintenance
Exterior Condition Notes
Window screens secured with removable, reusable, non-corrosive shipping clips
Ti i 8 00 14 5 S i "E " d t d f ti
• Indicate with an X in the Pass or Fail column if the unit passes or fails the requirement
• When a requirement includes measurement, indicate the measurement in the Notes column
• Supplement checklist by providing additional information in the Notes column
• If Exterior and Interior Inspector is same person, then write "Same" in 10-12
• If necessary, reattach all four pages before submitting checklist
Manufacturer
14. Final Acceptance (Signature and Print Name)
NON UFAS
UFAS
Year
EXTERIOR
Manufacturer removed exterior shipping materials, like plastic, wrap, nails, etc.
If no shrink wrap, not covered in or has residue of materials including oil, tar, or grease
2. Date of Inspection
3. Serial Number
1. FEMA Unit Identification Number
7. Printed Name of Exterior Inspector
10. Printed Name of Interior Inspector
8. Signature of Exterior Inspector
11. Signature of Interior Inspector
9. Date
12. Date
5. US Government Barcode (added after inspection)
4. Receiving Facility 6. Date of Acceptance
FEDERAL EMERGENCY MANAGEMENT AGENCY
Interim Contract - Manufactured Home Inspection Checklist v.AA (Rev. 4/5/12)
16. Unit Details 17. Unit Type 18. Instructions
Northern
Southern
FailPass
15. DateRecommendation to Accept / Deny
ACCEPT unit as is
DENY unit as is
Interim Contract ‐ Manufactured Home Inspection Checklist v.AA (Rev. 4/5/12) Page 1
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
Notes
All exterior penetrations are properly caulked
Drawbar
Bottom board is secured, moisture resistant under whole unit, prevents rodents from entering, and allows for cross tie anchoring buckles
Adequate number of axles as per contract (requirements provided post-award)
Fail
Non-rust rain channels are not punctured with weep holes over windows/doors, and are at least 1.5" high x 1" wide
Roof shingles are white or light colored composition shingle
Siding and corners are light grey, manufacturer's full vinyl siding or similar material;
soffits, trim, and J-block can either be the same light grey, or white
Notes
Tires are new size 8.00 x 14.5, Series "E," and not defective
Transportation system components installed with locking nuts or lock washers
Pass
Notes
Exterior Documentation
HUD Certification label placed on unit exterior (as required in 24 CFR 3280.11)
Manufactured Home ID is black, 4" high, and 2' from bottom of roof line
Manufactured Home Serial Number stenciled in contrasting color, 2” tall on the tongue; must match stamped serial number and serial number on HUD data plate
Drawbar welded (not bolted), made of 12" I-beam, and centered for towing
Welds and bar painted with rust-preventative paint: Blue/Northern or Red/Southern
Exterior
Unit number placard on exterior left front corner between 3" from the bottom of adjacent roof eve and no more than 3" from left edge of unit
Fail
Tire rims clamps, bolts, nuts, and related hardware are new
Fail
Pass
Documentation that the weight of the unit does not exceed the allowable weight for the number of axles provided
Weatherproof outdoor duplex receptacle flush mounted on exterior wall about 5' from water inlet, and 6" up from floor level
Pass
UL-approved weatherproof exterior light fixtures exist at each exterior door, and are metal with non-breakable globe Exterior heat tape receptacle is a single outlet with weatherproof case, is within two feet of water pipe inlet, and is not protected by GFCI For Nothern units only: This requirement shall include a second, double outlet
Interim Contract ‐ Manufactured Home Inspection Checklist v.AA (Rev. 4/5/12) Page 1
Serial No. :_______________________ Facility:_______________________ Inspector:_______________________ Date:_________________ ____
42.
43.
44.
45.
46.
Mark Location of Exterior Damage
47. Left Side
48. Right Side
49. Front 50. Back
NotesFailPassExterior (Continued)
Exterior doors have 1 peephole 5' 3" from finished floor AND 1 peephole 3' 7" from finished floor Roof penetrations capped with a galvanized metal cap (no rubber grommets) and painted to prevent rust
Hinged, metal service entrance junction box mounted to floor joist between I-beam and sidewall; 8" maximum between box and floor joist; within 10' maximum of right rear of unit without blocking exit
Exterior doors are 36” x 76,” hinged toward rear of unit, and do not block/touch windows when open
Wooden board or other material (which will not rust or rot) installed to deflect or prevent damage to “bottom board” or other items above the tires
Interim Contract ‐ Manufactured Home Inspection Checklist v.AA (Rev. 4/5/12) Page 2
51. Roof
52. Undercarriage
Interim Contract ‐ Manufactured Home Inspection Checklist v.AA (Rev. 4/5/12) Page 2
Serial No. :_______________________ Facility:_______________________ Inspector:_______________________ Date:_________________ ____
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
Stand-alone 1.2 cubic foot microwave with child lock OR combination microwave / hood / fan / light exists 30" self-cleaning 4 burner electric range with indicator light and thermostat-
Kitchen Pass Fail Notes
3 sets of keys with serial number and space for barcode, placed in sink
18 cubic foot frost-free refrigerator with freezer
Refrigerator is on its own circuit (check circuit breaker box for separately labeled refrigerator circuit breaker)
Refrigerator can be opened from inside (there are no locks on refrigerator door)
Refrigerator secured to floor and wall stud
Minimum 32" of counter space, not including dining table
Living Room Pass Fail
NOAA/FCC Weather Radios are equipped with strobe component that works with electrical power and battery backup; and there is at least one radio per bedroom
Notes
1 sleeper sofa, 1 arm chair, 1 coffee table, and 1 end table exist and are in new condition
Telephone and cable television jacks installed
Smoke alarms are audio/visual with strobe component and have battery backup
Smoke alarms have push-button testing and temporary silencing devices
Smoke alarms exists in living room, dining/kitchen area, and each bedroom
5 lb. A-B-C fire extinguisher exists with mounting bracket secured to wall stud in living room/kitchen area
Safety Devices Pass Fail
Notes
Unit Contact Placard on interior side of exterior doors, adjacent to upper peephole;
top of sign shall not be higher than 66” above finished floor Unit Contact Placard has white background, black 1” font stating “FEMA Owned & Maintained Unit Contact FEMA at 800-621-FEMA,” 8" space to write FEMA Unit Data Placard in interior side of water heater closet door, 3 inches from latch side, top of placard 5’ from bottom of the door, blue font 1/4" high
Notes
Internal Documentation Pass Fail
HUD Data Plate exists on/near main electrical panel, in kitchen cabinet, or in bedroom closet (as required in 24 CFR 3280.5)
Furniture packed in a manner so that it is not damaged during multiple transportations or in the unpacking process and is in the room it will be used
THU must be free from defective materials or workmanship
All joints (between trim and walls, molding and walls, molding and floors, etc.)
caulked to ensure tight seal
INTERIOR
Internal Condition Pass Fail Notes
Interim Contract ‐ Manufactured Home Inspection Checklist v.AA (Rev. 4/5/12) Page 3
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
88.
89.
90.
91.
92.
94.
Cabinetry is wall mounted
Lighted exhaust ceiling fan installed
All faucet assemblies include secondary dual shutoff valve for hot / cold water
Receptacle for range is flush mounted in the wall behind range
All faucet assemblies are dual shutoff valve
Minimum four receptacles are in the kitchen area above the counter
Industry standard toilet exists
Industry standard surfaced-mounted medicine cabinet with light (bathroom fixture) mounted on the vertical wall directly above the cabinet
Bathroom Pass Fail Notes
Standard 30" x 60" shower / tub combination exists
Curtain rod, shower curtain and curtain hooks, toilet paper roll holder, and towel rack are installed
Notes
Dining table is 3' x 5' (minimum), and composed of wood (free of porous fabric material) In 1- and 2-bedroom units, 4 dining chairs for adults exist; in 3-bedroom units, 6 dining chairs for adults exist; and all are composed of wood (free of porous fabric materials)
Dining Area Pass Fail
Hot water and drain pipes insulated and no sharp / abrasive surfaces under sink
Range is plugged in and secured to floor with 2 gusset angle brackets
Upper cabinetry is wall mounted, 36" long (continuous, minimum), and has fixed shelving Counter top is water resistant, and has caulking between top and backsplash of same material
Sink is stainless steel, self-rimming double-bowl, with spray nozzle of 12" extension and metal strainer basket
Counter space is 36" (continuous, minimum), supported by a base cabinet that has a single drawer and two doors
There is not a separate sidewall vent for range / oven controlled oven Lighted, power-vented hood range hood (one-piece construction OR combination microwave / hood / fan / light)
Interim Contract ‐ Manufactured Home Inspection Checklist v.AA (Rev. 4/5/12) Page 3
Serial No. :_______________________ Facility:_______________________ Inspector:_______________________ Date:_________________ ____
95.
96.
97.
98. Each bedroom has a 5-drawer dresser minimum 48"H x 33"W x 18" D
99. Each bedroom has at least one night stand
100. Each bedroom has at least one mattress, box spring, and metal bed frame
101.
102.
103.
104. Each bedroom has a receptacle on each wall
105. Each bedroom has smoke alarms with strobe component installed
106.
107.
108.
109.
110.
111.
112.
113.
114.
115.
116.
117.
118.
119.
Each bedroom has telephone and cable television jacks installed
Water heater compartment is labeled and states “No additional items shall be stored in the compartment”
Switches and thermostat 48" above finished floor
Bathroom, washer, and dryer are in same area and back-to-back to kitchen and water heater
Electrical outlets 18" above finished floor and not self-contained devices
Electric, 40 gallon (dual element) quick recovery water heater exists on individual circuit, and has pressure relief valve, drain pan, and metal tank drain valve
Interior access to water heater uses "SCHLAGE” brand key / dead bolt lock unique to closet (ensure that key works)
Plumbing, Appliances, Electrical, and Electronics Pass Fail Notes
1- and 2-bedroom units have electric service of 150 amps (minimum); 3-bedroom units have electrical service of 200 amps; master and branch circuit breaker panel flush-mounted on right side of back bedroom (120/240 volts, 4-wire, with individual water heater circuit taped in "off" position)
Appliances are Energy Star qualified
HVAC does not require additional installation and is not an adaption of a traditional split system where the compressor is designed to be installed separate from the
If no shrink wrap, weather proof covering on the external mounted portion of HVAC
Dryer vent, electrical connections, and water hookup for standard size washer and dryer are installed (no washer or dryer appliances are provided) Whole house electric HVAC system exists without individual / window HVAC appliances in each room; with digital thermostat and automatic settings; and with furnace or air handling unit (if applicable) in the water heater / furnace cabinet
All electrical circuits are clearly and legibly identified
Bedrooms Pass Fail Notes
If 2 or 3 bedrooms, one bedroom is larger
Each bedroom has an enclosed closet with minimum interior length of 32"
Closets have shelf and rod running length of closet with support at both ends
If Bedroom 2 exists, it has standard 54" x 75" full bed
Bedroom 1 has standard 54" x 75" full bed
If Bedroom 3 exists, it has two XL twin beds (39" x 75") on a free standing bunk bed frame (not built into the manufactured housing unit)
Interim Contract ‐ Manufactured Home Inspection Checklist v.AA (Rev. 4/5/12) Page 4
120.
121.
122.
123.
124.
125.
126.
127.
128.
129.
130.
131.
132.
133.
134.
135.
Windows Pass Fail Notes
Windows are double-paned, at least 30" x 54," with window screens & mini-blinds
No shutters, and labeled as and affixed with operating instructions for egress
Floor Covering Pass Fail
Molding Pass Fail
Notes
Interior floors are continuous roll, non-foam resilient, non-skid (no carpet)
A carpet scrap or doormat of about 30" x 15" is placed at each entrance
Heat duct openings are covered with 4" x 10" metal, adjustable louvered register
Notes
All trim molding is the same color - or color coordinated - to the interior paneling
All seals, joints, door / window frames, and corners (visible or not) are finished
All fixtures have CFL bulb equivalent to 60 watt bulb installed
Exposed panel edges are covered with permanently attached non-plastic edging
Notes
Lighting fixture in living/dining room, kitchen, each bedroom, bathroom, and hall
All interior lighting fixtures are ceiling mounted
Receptacles near wet areas are protected with ground fault interrupter
Shrink wrapped units have either solar or wind vent fans, and fans are placed in front of two windows on opposite sides (long side) of the unit
All interior lighting fixtures are wall-switch controlled with dual sockets
There are no hanging lights
Lighting Requirement Pass Fail
All fixtures are equipped with non-breakable shades (no glass permitted) stored in the compartment
Interim Contract ‐ Manufactured Home Inspection Checklist v.AA (Rev. 4/5/12) Page 4
Serial No. :_______________________ Facility:_______________________ Inspector:_______________________ Date:_________________ ____
136.
137.
138.
139.
140.
141.
142.
143.
144.
145.
146.
147.
148.
149.
150.
151.
152.
153.
154.
155.
156.
157.
158.
UFAS Visual Scan of Doorways, Hallways, Interior Receptacles and Bathroom
UFAS
Pass Fail Notes
Notes
Water closet between 15" and 19" from the top of the toilet seat
UFAS Visual Scan(Continued) Pass Fail
A device (like a rubber bumper) is installed to prevent water from escaping shower
Dining table is moveable on wheels or casters
Grab bars installed in shower on back wall and wall opposite seat between 33" and 36" above the finished floor (but not extended over seats)
Counter surface 34" high (maximum); bottom of mirror 40" high (maximum)
UFAS Bathroom Pass Fail
Cl fl f 30" 60"
Notes
Includes one of (a) accessible bathtub, (b) 36" x 36" transfer shower, or (c) 30" x 60" (minimum) roll in shower with no threshold or curve and non-skid surface Folding seat in shower is 17" to 19" in height, secured to short wall, and perpendicular to control wall
Handicap toilet installed with top of seat 17" to 19" from the floor
Notes
Appliances are not obstructed, have 30" x 48" clear floor space for forward/parallel approach
Sink is a maximum of 6.5" deep, 34" high, with knee clearance
Hot water and drain pipes insulated or protected and no sharp / abrasive surfaces under sink
Sinks and cabinets are wall-supported, and finished floors / walls exist under base cabinets
Self-cleaning oven with insulation on all sides
Hallways are a minimum of 36” wide
Refrigerator either vertical side-by-side type or over-under type with at least 1/2 freezer space under 54" above floor
Work surfaces are between 28" and 34" from the ground
UFAS Kitchen Pass Fail
All rooms include a turning radius of 60" or a T-shaped space
Knee clearance at tables, counters, and work surfaces is at least 27" high, 30" wide, and 19" deep
Switch to operate power vent operable with one hand
Doors - Open 90°; minimum opening 32"; raised thresholds/floor level changes beveled (maximum slope 1:2 and height 1/2"); handles extend 2" from door surface, and have 1.5" clearance on either side
Switches/receptacles above obstructions/countertops are 44" above finished floor
Oven self-cleaning or adjacent to adjustable height counter with knee space
Controls do not require reaching across burners
Interim Contract ‐ Manufactured Home Inspection Checklist v.AA (Rev. 4/5/12) Page 5
159.
160.
161.
162.
Notes / Comments
Electrical receptacle for TTY next to the living room phone jack
UFAS Living Room Pass Fail Notes
Hot water / drain pipes under lavatories are insulated / covered
Clear floor space of 30" x 60"
Flush controls mounted on the wide side of toilet, 44" above floor (maximum)
Interim Contract ‐ Manufactured Home Inspection Checklist v.AA (Rev. 4/5/12) Page 5