HSFEHQ-12-R-0002_Attach2.docx

DOCX document 102 KB Posted

Attached to
FEMA Temporary Housing Units Federal contract opportunity
Solicitation number
HSFEHQ-12-R-0002
Issued by
Federal Emergency Management Agency Logistics Section

About this file

RUGGED BASE PERFORMANCE REQUIREMENTS

View the file

Other files for this federal contract opportunity

Other files attached to FEMA Temporary Housing Units, newest first.
File Type Posted
HSFEHQ-12-R-0002 A00004.pdf PDF
HSFEHQ-12-R-0002_Solicitation 20120608 .pdf PDF
HSFEHQ-12-R-0002_Attach2_vAA_June 8 2012.pdf PDF
HSFEHQ-12-R-0002_Attach2_vAA_2012-04-05 _May 15 2012.pdf PDF
HSFEHQ-12-R-0002_A00003.pdf PDF
HSFEHQ-12-R-0002_A00002.pdf PDF
HSFEHQ-12-R-0002_AdditionalGovernmentResponses.pdf PDF
HSFEHQ-12-R-0002_A0001.pdf PDF
HSFEHQ-12-R-0002_Attach2.pdf PDF
HSFEHQ-12-R-0002_Solicitation.docx DOCX document
HSFEHQ-12-R-0002_GovtResponses.pdf PDF
HSFEHQ-12-R-0002_Attach2.pdf PDF
HSFEHQ-12-R-0002_Attach5.docx DOCX document
HSFEHQ-12-R-0002_Attach3.pdf PDF
HSFEHQ-12-R-0002_Attach4.docx DOCX document
HSFEHQ-12-R-0002_Attach6.docx DOCX document
HSFEHQ-12-R-0002_Attach8.xlsx XLSX spreadsheet
HSFEHQ-12-R-0002_Attach1.docx DOCX document
HSFEHQ-12-R-0002_Attach7.docx DOCX document
HSFEHQ-12-R-0002_Attach2.pdf PDF
HSFEHQ-12-R-0002_Solicitation.docx DOCX document
HSFEHQ-12-R-0002 P0001.pdf PDF
HSFEHQ-12-R-0002_Attach4.docx DOCX document
HSFEHQ-12-R-0002_Attach3.xlsx XLSX spreadsheet
HSFEHQ-12-R-0002_Solicitation.docx DOCX document
HSFEHQ-12-R-002_Attach1.docx DOCX document
PAST PERFORMANCE QUESTIONNAIRE.docx DOCX document
HSFEHQ-12-R-0002_Attach5.docx DOCX document
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

General Manufactured homes to be procured under this contract will be used as part of the Federal Emergency Management Agency’s authority under Section 408 of the Stafford Act to provide temporary housing to disaster survivors. The Agency intends to reuse these manufactured homes to house disaster survivors in several disaster events. These units will be subjected to extended road travel (in excess of 6,000 miles over their lifetime), multiple installations and un-installations, and a wide variety of weather conditions. The manufactured homes must meet all of the requirements including having a complete Heating, Ventilation and Air Conditioning system and being furnished as described.

Legal Requirements The manufactured homes (as defined in 24 CFR 3280) being procured using these Performance Requirements must meet and comply with all appropriate HUD requirements, regulations, standards, and guidance. This specification does not constitute any expressed or implied deviation or waiver of any requirements of the U.S. Department of Housing and Urban Development (HUD) Standards, Regulations, or its amendments or interpretative bulletins thereof. These units must comply with HUD Standards, Regulations, and other appropriate HUD guidance and require a HUD label to be placed inside the unit. All units must comply and meet the HUD approval process. These specifications do not provide the manufacturer with a waiver of the approval process for receiving an “Alternative Construction Letter (ACL).”FEMA anticipates that the manufacturer will have to apply for one or more ACL to meet the requirements of these specifications.

A downloadable copy of UFAS can be found at http://www.access-board.gov/ufas/ufas.pdf and a searchable copy can be found at http://www.access-board.gov/ufas/ufas-html/ufas.htm. Technical assistance on UFAS is available from the U.S. Access Board at 800-872-2253 or technical assistance – TA@access-board.gov.

Delivery Conditions Manufactured homes delivered to FEMA that do not meet all requirements will be rejected by the government until such time as the contractor, at their own expense completes all contract requirements. Any expense for reworking/repairing/modifying the manufactured home to bring into compliance with the terms and conditions of this contract shall be solely the expense of the contractor. If available, the government, may at its discretion, provide the contractor with space to make repairs.

Parties Throughout this document the reference of contractor, manufacturer, and vendor refers to the company awarded the contract. The company will be FEMA’s point-of-contact (POC) for all warranties, including warranties for the unit, furnace, water heater, all furnishings, and appliances.

Delivery Locations The primary delivery locations will be in Selma, AL and Cumberland, MD. Additional delivery locations may be specified by FEMA. Delivery may occur to more than a single location simultaneously. The contractor assumes all liability for loss or damage until FEMA accepts the manufactured home at the delivery location. The contractor must have a representative at each delivery location to authorize repairs, as well as staff with the technical capability to make required repairs at any government receiving facility (if space is available).

Manufacturing Requirements All materials and components used in the production of the manufactured homes under this contract shall all be new. This shall include all furnishings and appliances. The floor, shower, and tub areas must be constructed of non-absorbent surfaces that will not trap water and support mold growth.

Requirement Version Identifier This version of the requirements shall be designated:

AA

Any changes made to these requirements shall be designated as follows:

AB for the first change AC for the second change Etc.

Rugged Base Performance Requirements ITMUS All Manufactured Homes

FEMA Base Requirments ITMUS (9 January 2012).docx Page 5 of 41 Summary of Unit Features

This information is a general summary of the specifications.

001
Zoning Requirements
002
FEMA “Northern Units” Manufactured Housing Design Criteria in Accordance with 24 CFR 3280
003
Roof Load Zone
Middle
004
Thermal (U/O) Zone
3
005
Wind Zone
2
006
Thermal Identification
Painted Blue Draw Bar
007
FEMA “Southern Units “Manufactured Housing Design Criteria in Accordance with 24 CFR 3280
008
Roof Load Zone
South
009
Thermal (U/O) Zone
2
010
Wind Zone
3
011
Thermal Identification
Painted Red Draw Bar
012
Size and Configuration
3 Bedroom
2 Bedroom
1 Bedroom
014
Type
All Electric
All Electric
All Electric
015
Exterior Length
Not to exceed 60 ft

(box length)

Final dimensions shall be proposed by manufacturer
Final dimensions shall be proposed by manufacturer
016
Exterior Width
Not to exceed 14 ft

(box width) Final dimensions shall be proposed by manufacturer

Final dimensions shall be proposed by manufacturer

017
Area

Acceptable is defined as the minimum acceptable manufactured home size range.

Optimal is defined as the preferred manufactured home size range.

The Acceptable and Optimal manufactured home size ranges for the 3 bedroom units are the same – 840 square feet
Acceptable – Unit measures greater than 465 up to 550 square feet.

Optimal – Unit measures between 380 and 465 square feet.

Acceptable – Unit measures greater than 400 up to 460 square feet

Optimal – Unit measures between 340 and 400 square feet

018
Electrical System – AMPS
200 A
150 A
150 A
019
Electrical System – Volts
120/240 V
120/240 V
120/240 V
020
Furnishing
The contractor shall provide furnishing for each room. Furniture shall be packed in a manner so that it is not damaged during multiple transportations or in the unpacking process and it shall be located in the room where it is designated to be used.

UFAS – All manufactured homes designated as UFAS will comply with all applicable UFAS requirements. When placing furniture, furnishings shall not obstruct accessible routes providing circulation to spaces and rooms within the unit.

021
Living Room
Each unit will have a designated, usable living room area capable of accommodating the items as described under “furnishings”
022
Kitchen/Dining Room
Each unit will have a designated, usable kitchen/dining room area capable of accommodating the items as described under “plumbing service,” “furnishings,” “cabinetry” and “appliances.”
023
Bedrooms
Each bedroom designed for 2 people. Each bedroom shall meet the minimum 24 CFR 3880.109 (2) requirement. For both UFAS and non-UFAS, manufactured homes with more than one bedroom must designate a “Master Bedroom” which shall be larger in size than the other two bedrooms.

UFAS – The bedrooms shall contain a turning space complying with UFAS 4.2.3. Doors shall comply with UFAS 4.13.

024
Bathroom
The contractor shall equip all standard (non-UFAS) manufactured homes with a 30” x 60” shower/tub.

UFAS – The contractor shall equip all manufactured homes (UFAS) with 1 full bathroom which shall include a 30” x 60” roll in shower compliant with UFAS 4.23, UFAS 4.34 and UFAS 4.1.

025
Closets
Each bedroom shall have a closet that is 32 linear inches and that meets 24 CFR 3280.109(c).
026
Refrigerator
All manufactured homes shall contain a 18 cubic Foot - Frost Free - refrigerator with Freezer

UFAS – Compliant with UFAS 4.34.6.3 and 4.34.6.8.

027
Range, Oven and Vent Hood
All manufactured homes shall be equipped with a 30” self cleaning electric cooking range with a thermostatically controlled oven. The range/oven shall have an indicator light showing burners are on. In addition, each manufactured home shall have a lighted, power-vented range hood (one-piece construction). The manufacturer can substitute a microwave/hood/fan/light combination for the lighted, power-vented range hood.

UFAS – The manufacturer shall ensure that the Location of the controls for ranges burners, oven and vent shall not cause the user to reach across burners. Power vent shall have a switch to operate vent in compliance with UFAS 4.27. Shall comply with UFAS 4.34.6.6 and UFAS 4.34.6.7.

028
Washer and Dryer Hook-up
The manufactured home shall not include a washer and dryer; however, all manufactured homes shall have an area designated for the washer and dryer including the plumbing, electrical connections and dryer vent.

UFAS – Shall comply with UFAS 4.34.7.2. Controls shall comply with UFAS 4.27.

029
Air Conditioner
Yes, electric, central air (no window units)
030
Furnace
Yes
031
Microwave
Yes, stand alone, minimum 1.2 cubic foot with child lock unless this requirement is met through the use of a microwave/hood/fan/light combination.
032
Water Heater
Yes, Electric, 40 Gal (dual element) quick recovery.
033
Exterior Covering
Vinyl siding or similar (Color: light grey) in accordance with 24 CFR 3280.307.
034
Smoke Alarm
Yes, in accordance with 24 CFR 3280.208, including hallways. (See safety equipment for additional details.
035
Fire Extinguisher
Yes (See safety equipment for additional details.)
036
NOAA Weather Radio
Yes (see below for safety equipment for additional details.)
037
Hallways (UFAS manufactured homes only)
All hallways shall be a minimum of 36” wide. All hallways shall be UFAS compliant and all interior doors shall provide a 32” clear opening and comply with UFAS 4.13.
038
Sink (UFAS manufactured homes only)
The vanity and lavatory shall comply with UFAS 4.19. The kitchen sink shall comply with UFAS 4.24. Lavatories, sinks and countertops supporting them shall be wall-supported.
039
Plumbing Controls and Faucet Assemblies
All faucet assemblies in the home shall include secondary shut-off valves (one for each the hot and cold water supply).

UFAS – Plumbing controls, including faucet assemblies, must comply with relevant provisions of UFAS 4.16 to 4.24 and 4.27.

040
Pocket Door Hardware (UFAS manufactured homes only)
Handle on both sides of door shall extend 2” from door surface. Shall have 1.5” clearance on each side of handle. Shall be compliant with UFAS 4.13, UFAS 4.27 and UFAS 4.34.
041
CONTROLS AND OPERATING MECHANISMS (UFAS manufactured homes only)
All controls shall comply with UFAS 4.1 and UFAS 4.27.
042
Attic
A radiant barrier insulation system
043
Construction and Outfitting Specifications
044
Codes and Regulations
045
24 CFR 3280 (a.k.a. “HUD Code”)
A complete set of plans shall be provided for each unit type (Northern and Southern; UFAS and non-UFAS; and 1-, 2-, and 3-bedroom). Plans shall include, but not be limited to, floor plan, electrical/plumbing diagrams, and a materials list with Material Safety Data Sheets (MSDS). All plans shall demonstrate certification from DAPIA that all plans meet 24 CFR 3280 (“HUD Code”).

All units must bear the HUD label prior to shipment, and shall meet any solicitation-specific HUD defined ratings for Wind Zone, Temperature Zone, and Roof Load.

046
International Building Code (IBC)
Each unit shall include house wrap meeting the standards set forth in the 2003 International Building Code.
047
Uniform Federal Accessibility Standards (UFAS)
All units designated as “UFAS” or “Accessible” must be fully compliant with UFAS. UFAS “reminders” included throughout this specification are used to highlight certain standards, but are not all-inclusive, and the contractor shall be responsible for ensuring full compliance with UFAS.
048
Structural System
049
Main Frame
The main frame of the unit will be a 12" steel I-beam. The manufacturer shall provide and install two (2) additional I-beams of the same material and composition as the main frame shall extend a minimum of 18” on each side of the axle group, with each additional I-beam measuring 14’ 0” minimum in length. The additional I-beams will be installed by DAPIA approved to the inside of each frame and centered over the axle area in such a manner that the main frame I-Beam is doubled forward and aft through the axle area. The frame shall be secured to the floor joist system and the frame alignment shall be maintained by installing appropriate steel fasteners and lag bolts at every floor joist.
050
Outriggers
The manufacturer shall provide and install industry standard tapered outriggers (minimum twelve gauge), preformed C- or Z-type, and 12 gauge outriggers having a base of nine (9”) inches nominal. Outriggers shall be installed the entire length of the home at forty-eight inch (48”) on center (o.c.). The outriggers shall be mounted to the main frame I-Beam by DAPIA approved on both sides. The outriggers shall terminate flush with the perimeter floor joist and be secured at this point with a lag bolt. Additional outriggers will be provided and installed at each location where a shackle (spring hanger) is mounted to the main frame I-Beam.
051
Front/Rear Cross-Members
The manufacturer shall provide and install front and rear cross members (aprons). Each cross member will be the width of the unit and constructed of a minimum 12” I-Beam. Each cross member shall be fastened to the front and rear perimeter floor joists, respectively, with a minimum of six (6) lag bolts evenly spaced from corner to corner along the length of the cross member.
052
Auxiliary (Interior) Cross-Members
The manufacturer shall provide and install auxiliary (interior) cross members. The cross members shall be installed the entire length of the home, located between the two main frame I-Beams, be forty-eight inch (48”) on center, and within 3” of every outrigger.
053
Connections
All lag bolts must be at least 5/16” x 3” and be fully threaded. At least one lag bolt must be used to connect each outrigger to the perimeter joist and at least one lag bolt must be used to connect the 1”x 1/1/2” x 12 gage clip that is welded to each main I beam and connected to each floor joist at 16” on center.
054
Coatings
All exposed surfaces of the entire frame, shall be completely coated after welding. This coating must be waterproof. The serial number shall be painted with rust resistant black paint. Draw bar should be painted Blue to identify as FEMA “Northern Unit.” Draw bar should be painted Red to identify FEMA “Southern Unit.”
055
Floor Joists
The floor joists shall be 2” x 8” nominal and run transverse to the length of the unit. Floor joists shall be spaced sixteen (16”) inches on center (o.c.) and splicing of the floor joists is not acceptable. A 2” x 8” nominal rim member shall be installed to enclose the floor perimeter.
056
Floor Decking
The floor decking shall be composed of 4’x 8’ x 3/4” (23/32”) minimum thick plywood (approved sealed, non emitting plywood) panels with joists spacing index of 24 (long edges of the panel shall be tongue and groove) and with 16" o.c. floor joists. The decking should be placed perpendicular to the joist length. All plywood must be installed tongue and groove and secured in such a manner that the wood ends terminate on structural members for proper securing.
057
Floor and Ceiling
Floor and ceiling cavities will be insulated with flame retardant insulation having a minimum R rating of 19 in accordance with 24 CFR 3280.506. Condensation control (vapor barriers) will be installed in accordance with section 24 CFR 3280.504 of the Standard.
058
Interior Walls
A minimum 1” x 3” bottom plate shall be installed at all locations of interior walls. All interior walls studs shall be framed (studded) with minimum 2” x 3” nominal lumber spaced on 16” centers. Interior walls shall be secured to a minimum 2” x 3” top plate. All openings for interior doors and alcoves will be double framed with the same materials as the interior door studs and shall have headers/framing member from the top of the door to the ceiling.
059
Roof Trusses
Roof trusses shall be installed the entire length of the home on 16” centers and each must align with an exterior wall stud. The roof trusses shall not be cut for the passage of any electrical, plumbing, and/or mechanical system. Exterior roof coverings shall be secured to 3/8”structural rating sheathing. See Part 3280.305 (HUD standard)-Table of Design Wind Pressures.
060
Exterior Walls
The exterior wall framing (studs) shall be 2" x 6” nominal at 16” o.c. and secured to the top and bottom plate. The strapping of the wall studs to roof trusses and perimeter joists must be 26 gage minimum steel straps or brackets at 16" o.c to conform to the requirements of Wind Zone III.

The exterior walls shall be insulated with flame retardant insulation having a minimum R rating of 19. Condensation control (vapor barriers) will be installed in accordance with Part 3280 (HUD standard) 24 CFR 3280.504. The insulation shall be “batt” wall insulation for this application.

A strap must be secured to each full length wall stud on each side of all double-framed door and window openings. (Straps are not required on jack studs.)

All exterior openings such as windows, doors, drain pipes, etc., shall be caulked to prevent air and moisture penetration. All exterior penetrations (e.g. doors, windows, vents, lighting, and power outlets) shall be equipped with ice and water shields.

The unit must have a minimum 3/8” thick structural rated sheathing on all exterior walls.

061
House Wrap
House wraps shall be permeable weather barriers which allow air and water to escape from, but not enter, the unit. The house wrap shall be installed in accordance with the house wrap manufacturer’s instructions. The manufactured home vendor shall provide the house wrap installation instructions to FEMA upon request.

In addition to house wrap, all exterior penetrations (e.g. doors, windows, vents, lighting, and power outlets) shall be equipped with ice and water shields.

Air Supply Ductwork
All warm air supply ductwork shall be constructed of metal or insulated fiberglass materials and be complete with joint stays and sealed ends. All seams will be sealed with UL 181 or 181A-listed duct mastic tape, which will be verified before acceptance, with mechanical fastening to assure airtight construction with a maximum 3 percent duct loss. A pressure test shall be conducted before acceptance of the unit. No construction debris or sawdust may be left in the duct system.
063
Anchor Straps
Each home shall be equipped with vertical and diagonal straps to meet the requirements of 24 CFR 3280.306. All vertical and diagonal tie straps must be coated with zinc or other approved galvanic protection that provides at least .60 ounces per square foot of surface coating on all exposed sides. The anchor straps shall not be spliced.
064
Construction and Outfitting Specifications
065
Transportation System
066
Transportation System General
The transportation system components shall be installed with locking nuts or lock washers for all bolts.
067
Axles
All homes will be equipped new DAPIA approved axle assemblies. Axle assemblies supplied shall be designed for extensive use and long life application. The axles shall not be rated for light duty. Axles shall be rated the appropriate pounds at 50-mph and have a minimum rated axle of 6000 lbs. For all manufactured home types the contractor shall ensure and provide documentation that the weight of the manufactured home does not exceed the allowable weight for the number of axles provided. The weight of the manufactured home shall be calculated to include all items that are shipped with the manufactured home including all furniture and fixtures as well as any options exercised.

When the contractor calculates the number of axels they shall include one additional axel for increased safety.

Axel weight calculations and distribution may be verified by FEMA for any manufactured home delivered. If FEMA determines that the number of axels provided by the manufacturer is inadequate then the contractor shall at their expense install the additional axels wherever FEMA has stored or installed the manufactured home as well as modify all future manufactured homes delivered to FEMA.

Axles shall include grease fittings to facilitate maintenance of the axle hubs and bearings. The grease fittings shall be secured from environmental conditions when not being accessed during maintenance.

3 Bedroom
2 Bedroom
1 Bedroom
At least five axles. A minimum of three axles will be equipped with electric brakes within the capacity for the unit size and weight.
The contractor shall specify the number of axles and axles with breaks for the two bedroom units. The number of axles shall meet or exceed the minimum DOT requirements.
The contractor shall specify the number of axles and axles with breaks for the one bedroom units. The number of axles shall meet or exceed the minimum DOT requirements.
068
Outer Bearings
The minimum basic radial load shall be 1580 lbs. A minimum thrust rating for the capacity for the unit size and weight. The minimum required operating life is 3,000 hours.
069
Load Capacity
The minimum load capacity of the complete hub, drum and bearing assembly shall be rated for the design of the home. The hub/drum/armature shall be of a one-piece (unicast) type with the brake armature surface machined into the inner flat surface of the hub/drum casting. The brake drum surface shall also be machined for true operation.
070
Brakes
The electric brakes assemblies shall be manufactured to all SAE codes and have a design braking force to equal the minimum axle capacity for the unit size and weight.
071
Springs
Springs shall be of the multi-leaf type and appropriately rated with an over the axle mounting assembly (shackles, bolts, bushings, etc.). Shackled shall be secured to the main frame I-beams by continuous weld.
072
Tires and Rims
All tires and rims shall be new and free of defects. Tires shall be size 8.00 x 14.5, 10 ply Series “E.” Rim clamps, bolts, nuts or other related tire-mounting hardware must be new.
073
Drawbar
The drawbar should be three to four feet and will have to be welded not bolted. The drawbar ("A" frame) shall be made of 12" I-beam and installed in such a manner that it is centered for proper towing and is secured by continuous weld to two points on the front cross member and two points on the main frame I-beam. A cross member of the same material as the drawbar will be secured to the inside of the drawbar by continuous weld. The cross member will be located midway between the coupler hitch and the buckplates. An additional cross-member will be installed and secured by continuous weld inside the drawbar at the point where the drawbar legs are welded to the main frame I-beam.
074
The Screw Jack
The screw jack should be the industry standard bolt in type and galvanized .30 ounces per sq ft.

The screw jack shall include grease fitting to facilitate maintenance of the screw jack. The grease fitting shall be secured from environmental conditions when not being accessed during maintenance.

075
Exterior
076
Covering
077
Exterior Siding Covering
Unit siding shall be the manufacturer’s standard full vinyl siding materials or similar. The color shall be light grey.
078
Window Shutters
The manufactured home shall not have shutters.
079
Roof Covering
All roof assemblies must include non-rust rain channels. Rain channels shall not be punctured with weep holes over windows and doors. The minimum size of the rain channels is 1.5” H x 1” W. The roof must be installed within the manufacturer’s standard and constructed with adequate ventilation.

All roof penetrations (e.g. vents) shall be equipped with ice and water shields. An ice and water shield, consisting of at least two layers of underlayment cemented together or a self-adhering polymer modified bitumen sheet, shall be provided and extend from the lowest edges of all roof surfaces to at least 24 inches beyond the exterior wall.

The roof must have a shingle roof covering to resist the loads indicated in the Table of Design Wind Pressures in 24 CFR 3280.305 and be secured with 6 corrosion-resistant fasteners per shingle through underlayment which is cemented to 3/8” structural rated roof sheathing.

Light or white colored composition shingle with a minimum solar reflectance equal to or greater than Energy Star specifications for low sloped roof products.

All roof penetrations shall be capped with a galvanized metal cap. Rubber grommets shall not be used as they break down after approximately 6 month when the manufactured home is stored.

080
Bottom Board
Bottom board of the home shall be secured to prevent rodents from entering the unit and shall be moisture resistant under the entire home. The underside of the home shall be enclosed in accordance with 24 CFR 3280.305(g)(5). Plastic materials require a minimum of 20 mil thickness. Allowance to install cross tie anchoring buckles shall be made.
081
Bottom Board Tire Blowout/Road Hazard Damage Mitigation
The contractor shall install wooden board or other material that will deflect or prevent material from tire blowouts from damaging the “Bottom Board” or other items above the tires.

The material shall be on a type that will endure multiple manufactured home transportation, storage and installation/un-installation cycles without rotting or rusting.

082
Interior
083
Furnace
The unit will be equipped with at least a 95% efficient electric furnace (central heating system) capable of maintaining an average of 70 degrees Fahrenheit temperature. The furnace (central heating system) shall operate according to 3280.510. The furnace shall also be built or equipped for the installation of a package type air conditioner and have space in/on the furnace cabinet if required, for an A-coil evaporator unit and a 4-wire thermostat connects connections completely installed. Each furnace shall have instructions attached to the furnace. The furnace shall be complete with a factory-supplied base suitable for a forced air duct distribution system.

The furnace shall be able to maintain the temperature based on the coldest average temperature of the operating area of the manufactured home.

Units shall be designed to meet industry minimum standards for residential ventilation and acceptable indoor air quality standards per the American Society for Heating, Refrigeration and Air Conditioning Section 62 (ASHRAE 62).

3 bedroom
2 bedroom
1 bedroom
The output shall not be less than 40,000 BTU and in accordance with 24 CFR 3280.501 and 24 CFR 3280.701.
The contractor shall specify the output for the two bedroom units. The HVAC shall meet or exceed the ASHRE standards and in accordance with 24 CFR 3280.501 and 24 CFR 3280.701.
The contractor shall specify the output for the one bedroom units. The HVAC shall meet or exceed the ASHRE standards and in accordance with 24 CFR 3280.501 and 24 CFR 3280.701.
084
Air Conditioner
The home shall have a specifically engineered Heating, Ventilation and Air Conditioning system based on the size and intended use of the manufactured home, in accordance with ACCA Manual J requirements, that is compatible with the furnace and unit size. The contractor shall provide FEMA with documentation, engineering calculations and specifications upon request. The air conditioner system must be completely installed at the production facility. This includes duct work, installation manual, and any other materials needed for the installation. (Note: The air conditioner must be provided with the home.) The air conditioner must be the type that is installed on the side of the home and must be able to maintain an average of 75 degrees Fahrenheit temperature. Supply ducts shall be located in the ceiling. Shall comply with ASHRA 1989 handbook of fundamentals.

Units shall be designed to meet industry minimum standards for residential ventilation and acceptable indoor air quality standards per the American Society for Heating, Refrigeration and Air Conditioning Section 62 (ASHRAE 62).

The thermostat shall be a digital readout with automatic settings from heat/cool.

085
HVAC Damper
The HVAC system shall be equipped with a damper that will allow for the adjustment of the mixture of fresh air entering the manufactured home through the HVAC system. The damper shall be designed in such a way that a technician will be needed to adjust the damper setting. The damper should be in the closed or almost closed position when the manufactured home is delivered.
086
HVAC Installation
The HVAC unit shall not require additional installation when the manufactured home is installed. The HVAC unit shall not be an adaption of a traditional split system where the compressor is designed to be installed separate from the manufactured home.

If FEMA does not exercise the option to shrink wrap the entire manufactured home the contractor shall install a weather proof covering on the external mounted portion of the HVAC that shall prevent water penetration during transportation and storage of the manufactured home.

087
Electrical Service
088
Electrical System
The unit electrical service shall consist of a 120/240 volts 4-wire panel board, complete with master and branch circuit breakers. The distribution panel board shall be flush mounted inside the left exterior wall in the rear bedroom on road side. The panel board shall be of a dead front, safety type, equipped with thermal magnetic molded case circuit breakers of the quick break type having trip indicators and common trip on all multiple breakers. A circuit directory will be permanently affixed to the inside of the circuit breaker access door. All circuits will be clearly and legibly identified. Amperage shall be as previously identified.

The contractor shall place the water heater on an individual circuit. This circuit shall be clearly marker and the circuit shall be taped in the off position and the tape shall be labeled “Water Heater do not turn on until water service is turned on.”

089
Service Entrance Junction Box
Each home will be equipped with an appropriate hinged, metal service entrance junction box mounted to a floor joist between the I-beam and the sidewall in such a manner that the distance from the bottom side of the junction box to the floor joist is no more than eight inches (8").

The junction box shall be mounted at a sufficient distance from the outer edge, beneath the unit to prevent rainwater penetration the box without installing special rain shield. It shall also be located within 10 feet of the right rear (when facing the tongue) of the manufactured home.

The inlet must be functional, accessible and does not obstruct access to and/or from the door.

The conductors shall be continuously and appropriately color-coded or coded using colored tape wrapped around both ends of the conductors for a minimum of three inches (3"). Paint is not acceptable for coding wires.

The contractor shall not use aluminum wire to connect the service entrance box to the circuit breaker panel. The contractor shall ensure that the wire used to connect the breaker panel to the service entrance box meets the minimum electrical code in all 48 continental united states.

090
Telephone/ Cable Inlet
Each home will be equipped telephone/cable inlet.

The junction box shall be mounted at a sufficient distance from the outer edge, beneath the unit to prevent rainwater penetration the box without installing special rain shield. It shall also be located within 4 feet of the right rear (when facing the tongue) of the manufactured home.

The inlet must be functional, accessible and does not obstruct access to and/or from the door.

091
Lighting Requirement
Minimum interior lighting requirements shall include a ceiling mounted fixture in the bedrooms, hallways, kitchen, living room, dining area, water heater compartment, and bathroom. All lighting fixtures will be standard fixtures, and wall switch controlled. No hanging lights. The bathroom shall have a lighted exhaust ceiling fan.

UFAS – All light switches shall be compliant with UFAS 4.27. Where receptacles or switches are above obstructions, including countertops, locate them 44” maximum above finish floor.

092
Ventilation
Each bathroom exhaust fan must exhaust minimum 50 CFM directly to the outside. This is the measured flow, as installed, and not the rated flow by manufacturer.

Kitchen exhaust fan must exhaust minimum 100 CFM directly to the outside. Ventilation flow is measured as installed.

093
Fixtures and Receptacles
094
Exterior Fixtures
An “UL” approved weatherproof exterior lighting fixture and associated wiring will be provided at each exterior entrance/exit door. Fixture shall not be installed where rotation of bulbs would block exterior door exits. An interior wall switch will be installed near the exterior entrance/exit door the light serves.

The fixture shall be metal, 150-Degree Motion-Sensing Twin Flood Security Light, Gray in color. Fixture shall meet Energy Star guidelines. Appropriate Flood light bulbs shall be provided in a secure location in the kitchen.

All exterior penetrations (e.g. lighting and power outlets) shall be caulked with proper material and equipped with ice and water shields.

095
Interior Receptacles
Electrical receptacles will be installed at convenient locations throughout the unit. All electrical outlets shall be 18" above the finished floor. All switches and thermostat shall set at 48" above the finished of floor. Electrical receptacles will be installed in accordance with industry standard except that self-contained devices are not permitted. Receptacles near wet areas will be protected with ground fault interrupter protection. A minimum of four receptacles are required in the kitchen area above the counter. The receptacle for the range shall be flush mounted in the wall to the rear of the appliance. The receptacle for the refrigerator shall be located so it can be unplugged without moving the appliance. The unit will be equipped for electric washer and dryer hook-up.

Each bedroom shall have a receptacle on each wall.

UFAS – UFAS units shall have hookups for side-by-side Washers/Dryers

096
Washer/Dryer Hookups and Vent
Each unit shall be equipped with an electric Washer/Dryer hookup with dryer vent installed.

UFAS – UFAS units shall have hookups for side-by-side Washers/Dryers

097
Exterior Receptacles (Heat Tape)
Each home will be provided with a heat tape receptacle located under the unit and within two feet (2’) of the water pipe inlet. The heat tape receptacle shall be a single outlet with a weatherproof case. The exterior receptacle for the heat tape shall not be protected by a ground fault circuit interrupter. [24 CFR 3280.604(b)(4)(ii)]

For FEMA “Northern Units” only:

In addition, to the outlet as described above all northern units shall have one (1) weatherproof outdoor duplex receptacle that shall also be located under the unit and within two feet (2’) of the water pipe inlet. With the single receptacle for heat tape and the additional duplex receptacle, no less than three (3) outlets will be available under the unit and within two feet (2’) of the water pipe inlet.

098
Weatherproof Outdoor Duplex Receptacle
One (1) weatherproof outdoor duplex receptacle flush mounted on the exterior wall of the home, approximately five feet (5') forward of the water inlet and approximately six inches (6") up from the floor level.
099
Telephone and Cable Television outlets
Cable Television Jack: Each unit shall have a pre-wired television jack installed in the living room.

Telephone Jack: Each unit shall have a pre-wired telephone jack installed in the living room and master bedroom.

100
Interior Lighting Fixtures
All interior lighting fixtures shall be ceiling mounted, wall-switched controlled, and have dual sockets, be equipped with non-breakable shades, CFL bulb equivalent to 60 watt bulb installed. Lighting fixtures shall be provided in the living room, kitchen, all bedrooms, bathroom, hallways, and dining area. No glass is permitted.
101
Plumbing Service: The plumbing shall be on the left side on the unit when facing the unit tongue/drawbar/hitch.
102
Plumbing System
The main water supply pipe shall be of 3/4" CPVC or PEX and extend from the water heater compartment to a point not more than six inches (6") below the bottom board of the home. Distribution lines from the water heater compartment shall be not less than one-half inch (1/2") CPVC or PEX pipe for four (4) fixtures and shall not be less than three-quarter inch (3/4”) CPVC or PEX pipe for five (5) or more fixtures.

All connection lines from the 1/2" or 3/4” distribution lines to the fixture it supplies shall be of three-eighth inch (3/8") I.D. Type "L" copper with brass connectors or appropriate. The bathroom and washer and dryer shall be located within the same area of the home and back-to-back to the kitchen and water heater. The 3/4" main water supply inlet pipe will be equipped with a metal, 3/4" master shut-off valve (gate valve) and a 3/4" metal compression faucet (hose bib).

The contractor shall provide access panels in the walls at all points where plumbing joints exist. The access panels shall match the walls. An individual shutoff valve shall be provided at each installed plumbing fixture.

UFAS – The manufacturer shall install plumbing for a side-by-side Washer /Dryer.

103
Winterization
Water shall not be used to test water supply lines.

All drain lines shall have antifreeze poured into all traps, including washer drain, after the flood test.

104
Faucet Assemblies
All faucet assemblies in the home shall include secondary shut-off valves (one for each the hot and cold water supply).
105
Kitchen Sink
Each home will have completely installed a self-rimming double bowl, stainless steel sink. Shall have one spray nozzle with minimum 12” extension. Each sink bowl will be fitted with a metal strainer basket assembly and appropriately sized strainer baskets. Hot water and drain pipes must be insulated to protect against contact. Also there shall be no sharp or abrasive surfaces underneath.

UFAS – The kitchen sink shall comply with UFAS 4.24. Lavatories, sinks and countertops supporting them shall be wall-supported. Provide easily removable base cabinets with finished floors and walls beneath. Kitchen appliances must not be obstructed by furnishings. Each kitchen appliance must have a clear floor space for a forward or parallel approach. See UFAS 4.2.4. Locate controls for ranges, burners and vents to avoid reaching across burners. Shall be in compliance with UFAS 4.34 and UFAS 4.27. Provide a self-cleaning oven with insulation on all sides to prevent excessive heat exposure. The kitchen shall contain a turning space complying with UFAS 4.2.3

106
Drainage System
All fixtures will be provided with an adequate drainage system, each connecting to a main sewer line, which will run below the floor and above the bottom board to the place of exit in the rear of the axles. The sewer line will exit the home not less than two feet (2') but not more than three feet (3') behind the rear axle. The exit pipe shall protrude at least six inches (6"), but not more than eight inches (8"), from the bottom board, shall have a threaded end, and be capped with a removable plastic cap and chain. The drainage system must be accessible without removing the axles for installations and deactivations.

All water lines shall be installed to a point above the flooring in such a manner that opening of the valves result in the complete drainage of the water lines. The drain valves shall be brass.

107
Shower
The contractor shall equip all standard (non-UFAS) manufactured homes with a 30” x 60” shower/tub with a non-skid surface. The shower/tub shall be installed in accordance with the shower/tub manufacturer’s instructions.

The manufactured home shall include a curtain rod, shower curtain and curtain hooks.

UFAS – The contractor shall install a 30” x 60” roll in shower with a non-skid surface. Showers shall be roll-in type and shall comply with UFAS 4.21. All showers shall have seats. Seats in roll-in showers shall be secured to the short wall perpendicular to the control wall and shall be of a folding type. Seat shall have a height of 17” to 19”. Shower shall comply with figure 35(b).

Showers shall have grab bars on the back wall and the side wall opposite the seat. All grab bars shall be installed 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface. One continuous grab bar or two grab bars are permitted. Grab bars shall not extend over seats.

The seat shall be a folding type and shall be installed on the side wall adjacent to the controls. The top of the seat shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor. Seats shall be L-shaped or rectangular in compliance with UFAS Figure 36.

The contractor shall insure that the UFAS shower does not allow water to flow out from the base when the shower is used properly. This may include the use of a rubberized “bumper” to act as a water dam.

The shower shall be installed in accordance with the shower manufacturer’s instructions.

The manufactured home shall include a curtain rod, shower curtain and curtain hooks.

108
Commode
The vendor shall equip the bathroom with an industry standard toilet.

UFAS – The commode shall comply with UFAS 4.34.5.2

109
Washer/Dryer Area
The manufactured home vendor shall include a designated area for washer/dryer. The area shall have the appropriate plumbing, electrical and vent connections for an electric washer and dryer. The area must accommodate a standard size washer and dryer.

UFAS – The washer/dryer area in the UFAS manufactured homes shall comply with UFAS 4.34.7 and include area for side by side washer/dryer installation. The area must accommodate a standard size washer and dryer.

110
Water Heater Compartment
The manufactured home vendor shall provide interior access to the water heater the interior access door shall be appropriately sized and located as to allow easy replacement of the water heater should it need to be replaced.

The hot water compartment shall be labeled as a hot water compartment. The label shall include an admonition that states “No additional items shall be stored in the compartment.”

The compartment shall have a light fixture and bulb to allow for maintenance.

Access shall be provided through a door that is keyed with a single master key.

The master key for access to the hot water compartment shall be unique and not match any other key used for interior or exterior locks providing access to the manufactured home unless specifically designated (i.e., fire sprinkler compartment).

The manufacturer shall ensure that there is adequate warm air from the interior of the manufactured home into the water heater compartment so that the water heater compartment is maintained at a temperature high enough that water stored in or flowing through the compartment does not freeze.

111
Water Heater Compartment Standard Key
Manufacturer shall secure the compartment door utilizing a “SCHLAGE” brand 6-pin Everest cylinders in C123 keyway (dead bolt lock), that shall be keyed to a 6 pin combination. The key combination shall be 746105. This key combination shall not be used anywhere else in the manufactured home or in the master key set.

The manufacturer shall provide keys for the Water Heater Compartment as follows:

1. 15 copies of the key to the COR

2. 15 copies of the key to each delivery location prior to the arrival of the first manufactured home for each task order issued.

112
Water Heater
A 40-gallon electric dual element quick recovery water heater. The water heater will be complete with a pressure relief valve, drain pan, and a metal tank drain valve. The valves and drain pan shall be separately piped four inches (4") to six inches (6") below the bottom board of the home and shall be at least five inches (5") away from the water inlet pipe. The water drip collection pan, relief valve and drain pan shall be separately piped to the exterior. Piping shall be installed at the factory. Place relief valve to exterior but pointed down with downward directed outlet to ground.
113
Appliances
The vendor shall ensure that all appliances must be high-efficiency appliances and energy star qualified.

The manufactured home vendor shall leave all labels that are affixed to the appliances designating that the appliances are high-efficiency or energy star qualified in place.

UFAS – Each kitchen appliance must have a clear floor space for a forward or parallel approach. See UFAS 4.2.4.

Locate controls for ranges, burners and vents to avoid reaching across burners. Shall be in compliance with UFAS 4.34 and UFAS 4.27.

114
Range/Oven
The contractor shall install a 30" self cleaning electric cooking range/oven. It shall include four (4) burners, a thermostatically controlled lighted oven, and indicator lights that show that the burners are operating or are warm. Range/oven controls shall be located so that the user does not have to reach across burners to use the range/oven. The oven shall have insulation on all sides to prevent excessive heat exposure.

The range/oven shall be secured to the floor with two (2) angle (gusset type) brackets. The range/oven shall be plugged into the receptacle.

UFAS – Locate controls for range burners and oven to avoid reaching across burners. Shall be in compliance with UFAS 4.34 and UFAS 4.27.

115
Power Vented Hood
A lighted, power-vented range hood (one-piece construction) unless a combination microwave is installed. A separate sidewall vent (that is not part of a hood or microwave) is not acceptable.

UFAS – Power vent shall have a switch to operate vent in compliance with UFAS 4.27.

116
Refrigerator
18 cubic feet (c. f.) frost-free refrigerator with freezer. The refrigerator shall be secured to the floor and to a wall stud. The refrigerator shall be plugged into its receptacle. The refrigerator shall be on its own circuit. The refrigerator must be able to be opened from the inside.
117
Microwave Oven
Each unit will have a minimum 1.2 cu. ft microwave with child lock unless this requirement is met through the use of a microwave/hood/fan/light combination.
118
Furnishings
Quality furniture requires good construction. Chair / sofa cushions and sofa beds shall be comfortable and durable. All furniture construction should adhere to the national standards of the appropriate furniture industry. Fabric and style must sustain rough and tumble usage. Fabric should be flame retardant in keeping with federal flammability standards. All fabric furniture shall have stain resistance protection.

All furniture shall be assembled with all packing material removed from the manufactured home. All furniture shall be transported upright and packed so that the furniture is not damaged during transportation. Historically, furniture has been packed against the front wall of the room or area it services. Tape shall not be used to secure furniture for transport.

119
Bedrooms
All units must provide sleeping capacity to accommodate two persons in each bedroom, and two persons on a pull-out (sleeper) sofa in the living area. The master bedroom will be designated Bedroom 1. Second and third bedrooms will be designated Bedroom 2 and Bedroom 3, respectively. Bedrooms will be designated by size with the smallest bedroom being designated with the highest number.

Each bedroom will be furnished with the following:

· bed(s) for two persons (including mattress, box spring and metal bed frame) defined as one of the following:

· Master Bedroom - one standard queen size bed (60” x 80”);

· Second Bedroom - one standard full size bed (54” x 75”);

· Third Bedroom:

· one standard full size bed (54” x 75”); or,

· two standard twin size beds (each 39” x 75”)

· one five-drawer dresser (minimum 48” H x 33” W x 18” D)

· one nightstand

In all bedrooms, on three sides of all beds, there shall be both a minimum of 18” between the bed and the wall as well as open access to the same three sides of the bed.

UFAS – The bedrooms shall contain a turning space complying with UFAS 4.2.3. Doors shall comply with UFAS 4.13

Reminder: In UFAS units, there needs to be either 32” or 36” on at least one open-access on one of the long sides of the bed to provide an accessible path.

120
Pocket Door Hardware
UFAS – If the vendor proposes the use of pocket doors in a UFAS manufactured home the handle on both sides of door shall extend 2” from door surface. Shall have 1.5” clearance on each side of handle. Shall be compliance with UFAS 4.13, UFAS 4.27 and UFAS 4.34.
121
Living Room
Each living room area will be furnished with one (1) sleeper sofa (double/full size mattress with dimensions of 54” x 75”), one (1) armchair, one (1) coffee table, and one (1) end table.

UFAS – The living room shall contain a turning space complying with UFAS 4.2.3 and 4.3 with the sofa bed open or closed as well as provide an accessible path with the sofa bed open or closed

122
Dining Room
The dining room area will be furnished with dinette table. The minimum size of the table shall be 3’x5’.
3 Bedroom manufactured home requirement
2 Bedroom manufactured home requirement
1 Bedroom manufactured home requirement
1 table with 6 chairs to accommodate six adults
1 table with 4 chairs to accommodate 4 adults
1 table with 4 chairs to accommodate 4 adults

UFAS – The dining table shall be movable on wheels or casters. The table shall comply with UFAS 4.32. Shall contain a turning space complying with UFAS 4.2.3.

123
Safety Equipment
124
Smoke Alarms
Each unit will have interconnected smoke alarms that utilize the electrical system of the home as the primary power source (w/battery back-up included). Smoke alarms shall be equipped with push-button testing and temporary silencing devices. Provide a smoke detector in each bedroom and in the living room/dining/kitchen area. Each alarm shall follow 24 CFR 3280.208. Shall be equipped with a strobe component. Each unit, both UFAS and non-UFAS, shall be equipped with an audio/visual smoke alarm.
125
Fire Extinguisher
Each home will be equipped with a five-pound A-B-C type fire extinguisher and a mounting bracket. The mounting bracket will be secured to a wall stud in the kitchen/living area.
126
NOAA Weather Radios

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .