Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICITATION

NO.

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO.

IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

NSN 7540-01-152-8070

Previous edition unusable

000003

The purpose of this amendment is to incorporate changes to RFP HSCG85-16-R-P45245.

1. RFP Attachment 1 (References, WIs: 19 and 42):

Remove the following pages from Attachment 1 and replace with the pages appending to this amendment: x, xi, 96-99, and 273-274.

Changes are annotated with a line on the left.

UNITED STATES COAST GUARD

SURFACE FORCES LOGISTICS CENTER

1519 ALASKAN WAY

SEATTLE, WA 98134

HSCG85-16-R-P45245

1 9

12/21/2015

12/04/2015

USCGC POLAR STAR (WAGB-400) DRYDOCK AVAILABILITY FY2016

x (Draft-0)

Manufacturers Standardization Society of the Valve and Fittings Industry (MSS), SP-58, 2009, Pipe Hangers and Supports – Materials, Design, Manufacture, Selection, Application and Installation

MIL-A-18001, May 2005, Anodes, Sacrificial Zinc Alloy (Commercially Accepted -

ASTM B418)

MIL-A-22262, Mar 1996; Abrasive Blasting Media Ship Hull Blast Cleaning

MIL-D-16791, Jan 1993, Detergents, General Purpose (Liquid, Nonionic)

MIL-G-24716, Apr 1993, Gaskets, Metallic-Flexible Graphite, Spiral Wound

MIL-PRF-1149, Jun 1998, Gasket Materials, Synthetic Rubber, 50 and 65 Durometer

MIL-PRF-24613, Dec 1990, Deck Covering Materials, Interior, Cosmetic Polymeric

MIL-STD-777, Schedule of Piping, Valves, Fittings, and Associated Piping Components for Naval Surface Ships

Naval Sea Systems Command (NAVSEA) Standard Item 009-31, July 2011, Boiler Waterjet Cleaning

Naval Sea Systems Command (NAVSEA) Technical Directive S6430-AE-TED-010 Piping Devices, Flexible Hose Assemblies

Naval Sea Systems Command (NAVSEA) T9074-AS-GIB-010/271, Apr 1997, Requirements for Nondestructive Testing Methods

Naval Ships’ Technical Manual (NSTM) Ch 221, May 2010, Boilers

Naval Ship's Technical Manual (NSTM) Chapter 243, May 2006, Propulsion Shafting

Naval Ships’ Technical Manual (NSTM) Ch 244, 2011, Propulsion Bearings and Seals

Naval Ships' Technical Manual, Chapter 556, Hydraulic Equipment Power Transmission and ControlNaval Ships’ Technical Manual (NSTM) 541, 2007, Ship Fuel and Fuel Systems

Society of Automotive Engineers (SAE) Aerospace Material Specification (AMS) C6183, 2013, Cork and Rubber Composition Sheet; For Aromatic Fuel and Oil Resistant Gaskets

Society of Automotive Engineers (SAE) Aerospace Material Specification (AMS) G- 6032, 2014 Grease, Plug Valve, Gasoline and Oil Resistant, NATO Code Number G-363, Metric

STANDARD SERVICE MODULE 131-106-004 Polar Class Re-installation of Hayward Strainers

The Society for Protective Coatings (SSPC) Surface Preparation Specification No.1 (SSPC-SP 1), 2004, Solvent Cleaning

The Society for Protective Coatings (SSPC) Surface Preparation Specification No.11 (SSPC-SP 11), 2012, Power Tool Cleaning to Bare Metal

The Society for Protective Coatings (SSPC) Surface Preparation Specification No.3 (SSPC-SP 3), 2004, Power Tool Cleaning

The Society for Protective Coatings (SSPC), May 2012, Paint Application Specification No. 2 (PA-2), Measurement of Dry Coating Thickness with Magnetic Gages

The Society for Protective Coatings (SSPC)/NACE International (NACE) Joint Surface Preparation Standard SSPC-SP WJ-2/NACE WJ-2, 2012, Waterjet Cleaning of Metals – Very Thorough Cleaning xi (Draft-0)

The Society for Protective Coatings (SSPC)/NACE-International (NACE) Joint Surface Preparation Standard SSPC-SP 10/NACE No. 2, 2007, Near-White Blast Cleaning

The Society for Protective Coatings (SSPC)/NACE-International (NACE) Joint Surface Preparation Standard SSPC-SP 12/NACE No. 5, Surface Preparation and Cleaning of Steel & Other Hard Materials by High and Ultrahigh Pressure Water Jetting Prior to Recoating

The Society for Protective Coatings (SSPC) Surface Preparation Standard SSPC-SP 15, Commercial Grade Power Tool Cleaning

Thordon Double Key XL Bearing Installation Manual 10 May 2006

Thordon XL Double Key Bearing Assembly DWG No. TG-17321 (Thordon Bearing Inc.)

Thordon XL Double Key Bearing Carrier DWG No. TG-17344 (Thordon Bearing Inc.)

96 (Draft-0)

S_50500_ESD_0515_SWIT

SYY_LLNNN_50500_AUT_MMYY_HULL#

WORK ITEM 19: Flex Hose Assemblies, Renew

1. SCOPE

1.1 Intent. This work item describes the requirements for the Contractor to renew hose assemblies identified in Table 1.

TABLE 1 – HOSE PARTICULARS

Item # Hose Number Location System Int/Ext Preferred Hose Type Length Size Fitting Type

Fitting Material

1 1AB-F/O-001 5-113-0-E Fuel Oil Internal IAW SAE J 1942 36" 1/2" STRx2 F Monel

110 1AB-F/O-002 5-113-0-E Fuel Oil Internal IAW SAE J 1942 56" 1/2" STRx2 F Monel

111 1AB-F/O-003 5-113-0-E Fuel Oil Internal IAW SAE J 1942 84" 1/2" Threaded Monel

2 1DOP-OIL-001 5-57-0-E Fuel Oil Internal IAW SAE J 1942 8" 2" Threaded Monel

3 1DOP-OIL-002 5-57-0-E Fuel Oil Internal IAW SAE J 1942 8" 2" Threaded Monel

4 1DOP-OIL-003 5-57-0-E Fuel Oil Internal IAW SAE J 1942 14" 1/4" Threaded Monel

112 1SSA-A-001 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 36" 2" Threaded Monel

7 1SSA-A-002 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 48" 1 1/2" Threaded Monel

8 1SSA-A-003 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 48" 1 1/2" Threaded Monel

9 1SSA-A-004 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 36" 2" Threaded Monel

10 1SSA-L/O-001 3-121-0-E Lube Oil Internal IAW SAE J 1942 48" 1" Threaded Monel

11 1SSA-L/O-002 3-121-0-E Lube Oil Internal IAW SAE J 1942 36" 1" Threaded Monel

12 1SSA-L/O-003 3-121-0-E Lube Oil Internal IAW SAE J 1942 24" 1" Threaded Monel

13 1SSA-L/O-004 3-121-0-E Lube Oil Internal IAW SAE J 1942 28" 1" Threaded Monel

14 2DOP-OIL-001 5-85-0-E Fuel Oil Internal IAW SAE J 1942 8" 2" Threaded Monel

15 2DOP-OIL-002 5-85-0-E Fuel Oil Internal IAW SAE J 1942 8" 2" Threaded Monel

16 2DOP-OIL-003 5-85-0-E Fuel Oil Internal IAW SAE J 1942 14" 5/16" Threaded Monel

17 2DOP-OIL-004 5-85-0-E Fuel Oil Internal IAW SAE J 1942 14" 5/16" Threaded Monel

21 2SSA-A-001 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 36" 2" Threaded Monel

22 2SSA-A-002 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 48" 1 1/2" Threaded Monel

23 2SSA-A-003 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 48" 1 1/2" Threaded Monel

24 2SSA-A-004 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 36" 2" Threaded Monel

25 2SSA-L/O-001 3-121-0-E Lube Oil Internal IAW SAE J 1942 48" 1" Threaded Monel

26 2SSA-L/O-002 3-121-0-E Lube Oil Internal IAW SAE J 1942 36" 1" Threaded Monel

27 2SSA-L/O-003 3-121-0-E Lube Oil Internal IAW SAE J 1942 24" 1" Threaded Monel

28 2SSA-L/O-004 3-121-0-E Lube Oil Internal IAW SAE J 1942 24" 1" Threaded Monel

97 (Draft-0)

Item #

Hose Number Location System Int/Ext Preferred Host Type Length Size Fitting Type

Fitting Material

31 EDG-F/O-001 02-119-0-E Fuel Oil Internal IAW SAE J 1942 42" 3/4"

STR FL/90

FL Monel

32 EDG-F/O-002 02-119-0-E Fuel Oil Internal IAW SAE J 1942 18" 3/4" STRx2 F Monel

33 EDG-F/O-003 02-119-0-E Fuel Oil Internal IAW SAE J 1942 60" 5/8" STRx2 F Monel

34 EDG-F/O-004 02-119-0-E Fuel Oil Internal IAW SAE J 1942 120" 1/2" STRx2 F Monel

35 EDG-F/O-005 02-119-0-E Fuel Oil Internal IAW SAE J 1942 18" 1/2" STRx2 F Monel

36 EDG-F/O-006 02-119-0-E Fuel Oil Internal IAW SAE J 1942 120" 5/8" STRx2 F Monel

37 EDG-F/O-007 02-119-0-E Fuel Oil Internal IAW SAE J 1942 144" 5/8" STRx2 F Monel

38 EDG-F/O-008 02-119-0-E Fuel Oil Internal IAW SAE J 1942 18" 1/4" STR F/90F Monel

39 EDG-F/O-009 02-119-0-E Fuel Oil Internal IAW SAE J 1942 12" 1/4" STR F/90F Monel

40 EDG-F/O-010 02-119-0-E Fuel Oil Internal IAW SAE J 1942 16" 1/4" STR F/90F Monel

41 EDG-F/O-011 02-119-0-E Fuel Oil Internal IAW SAE J 1942 16" 1 1/4" STR F/90F Monel

42 EDG-F/O-012 02-119-0-E Fuel Oil Internal IAW SAE J 1942 132" 1/4" STRx2 F Monel

43 EDG-F/O-013 02-119-0-E Fuel Oil Internal IAW SAE J 1942 18" 5/8"

STR FL/90

FL Monel

44 EDG-J/W-001 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 92" 3/4" STRx2 F Monel

45 EDG-J/W-002 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 120" 3/4" STRx2 F Monel

46 EDG-J/W-003 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 120" 1/4" STRx2 F Monel

47 EDG-J/W-004 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 56" 3/4" STRx2 F Monel

48 EDG-J/W-005 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 120" 3/4" STRx2 F Monel

49 EDG-J/W-006 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 48" 3/4" STRx2 F Monel

50 EDG-J/W-007 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 18" 1/4" STRx2 F Monel

51 EDG-L/O-001 02-119-0-E Lube Oil Internal IAW SAE J 1942 104" 1/4" STRx2 F Monel

52 EDG-L/O-002 02-119-0-E Lube Oil Internal IAW SAE J 1942 12" 1/4" STRx2 F Monel

53 EDG-L/O-003 02-119-0-E Lube Oil Internal IAW SAE J 1942 10" 1/4" STRx2 F Monel

54 EDG-L/O-004 02-119-0-E Lube Oil Internal IAW SAE J 1942 48" 1/4" STRx2 F Monel

55 EDG-L/O-005 02-119-0-E Lube Oil Internal IAW SAE J 1942 48" 1/4" STRx2 F Monel

56 EDG-L/O-006 02-119-0-E Lube Oil Internal IAW SAE J 1942 48" 1/4" STRx2 F Monel

57 EDG-L/O-007 02-119-0-E Lube Oil Internal IAW SAE J 1942 48" 1/4" STRx2 F Monel

58 EDG-L/O-008 02-119-0-E Lube Oil Internal IAW SAE J 1942 60" 5/16" STRx2 F Monel

59 EDG-L/O-009 02-119-0-E Lube Oil Internal IAW SAE J 1942 28" 3/4" STRx2 F Monel

60 EDG-L/O-010 02-119-0-E Lube Oil Internal IAW SAE J 1942 16" 3/4" STRx2 F Monel

61 EDG-L/O-011 02-119-0-E Lube Oil Internal IAW SAE J 1942 12" 1 1/2" STRx2 FL Monel

62 EDG-L/O-012 02-119-0-E Lube Oil Internal IAW SAE J 1942 12" 1 1/2" STRx2 F Monel

65 L-STM-001 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 12" 3/4" STRx2 M Monel

66 L-STM-002 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 14" 1 STRx2 M Monel

67 L-STM-003 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 12" 3/4" STRx2 M Monel

68 L-STM-004 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 12" 3/4" STRx2 M Monel

69 L-STM-006 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 18" 3/8" Threaded Monel

98 (Draft-0)

Item # Hose Number Location System Int/Ext Preferred Hose Type Length Size Fitting Type

Fitting Material

70 L-STM-007 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 22" 3/8" STRx2 M/F Copper

71 L-STM-011 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 22" 3/8" STRx2 M/F Copper

72 L-CFW-001 1-18-1-Q Fresh Water Internal IAW NAVSEA S6430-AE-TED-010 8" 1 1/4" STRx2 Monel

73 L-CFW-002 1-18-1-Q Fresh Water Internal IAW NAVSEA S6430-AE-TED-010 8" 1 1/4" STRx2 Monel

74 L-HFW-001 1-18-1-Q Fresh Water Internal IAW NAVSEA S6430-AE-TED-010 8" 1 1/4" STRx2 Monel

75 L-HFW-002 1-18-1-Q Fresh Water Internal IAW NAVSEA S6430-AE-TED-010 8" 3/4" STRx2 Monel

76 L-HFW-003 1-18-1-Q Fresh Water Internal IAW NAVSEA S6430-AE-TED-010 8" 1 1/4" STRx2 Monel

77 L-STM-005 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 22" 3/8" STRx2 M/F Monel

79 L-STM-008 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 18" 3/8" Comp Flare Copper

80 L-STM-009 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 22" 3/8" STRx2 M/F Monel

81 L-STM-010 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 18" 3/8" UNK Monel

83 L-STM-012 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 18" 3/8" Comp Flare Copper

84 L-STM-013 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 22" 3/8" STRx2 M/F Monel

85 L-STM-014 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 18" 3/8" UNK Monel

86 L-STM-015 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 22" 3/8" STRx2 M/F Copper

87 L-STM-016 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 18" 3/8" Comp Flare Copper

P15TC-HYD-

001 Port Crane Hydraulic External IAW SAE J 1942 24" 1 1/4" STRx2 Stainless

P15TC-HYD-

002 Port Crane Hydraulic External IAW SAE J 1942 36" 1 1/4" STRx2 Stainless

P15TC-HYD-

003 Port Crane Hydraulic External IAW SAE J 1942 30" 3/4" STRx2 Stainless

P15TC-HYD-

004 Port Crane Hydraulic External IAW SAE J 1942 36" 1" STRx2 Stainless

P15TC-HYD-

005 Port Crane Hydraulic External IAW SAE J 1942 36" 1" STRx2 Stainless

P15TC-HYD-

006 Port Crane Hydraulic External IAW SAE J 1942 30" 1 1/4" STRx2 Stainless

P15TC-HYD-

007 Port Crane Hydraulic External IAW SAE J 1942 12" 1 1/4" STRx2 Stainless

POTW-CHL-

004 3-171-0-E Potable Water Internal IAW NAVSEA S6430-AE-TED-010 16" 3/8" STRx2 Monel

99 R2-S/W-001 2-35-1-Q Sea Water Internal IAW SAE J 1942 18" 1" STRx2 F Monel

100 R2-S/W-002 2-35-1-Q Sea Water Internal IAW SAE J 1942 16" 1" STRx2 F Monel

101 1AREF-R-001 3-57-0-E Refrigerant Internal IAW NAVSEA S6430-AE-TED-010 14" 1" Brazed Monel

102 1BREF-R-001 3-57-0-E Refrigerant Internal IAW NAVSEA S6430-AE-TED-010 14" 1" Brazed Monel

103 2AREF-R-001 3-57-0-E Refrigerant Internal IAW NAVSEA S6430-AE-TED-010 14" 1" Brazed Monel

104 2BREF-R-001 3-57-0-E Refrigerant Internal IAW NAVSEA S6430-AE-TED-010 14" 1" Brazed Monel

105 3AREF-R-001 3-57-0-E Refrigerant Internal IAW NAVSEA S6430-AE-TED-010 14" 1" Brazed Monel

106 3BREF-R-001 3-57-0-E Refrigerant Internal IAW NAVSEA S6430-AE-TED-010 14" 1" Brazed Monel

107 SA-A-001 3-121-0-E Start Air Internal IAW NAVSEA S6430-AE-TED-010 36" 2" Threaded Monel

108 SA-A-002 3-121-0-E Start Air Internal IAW NAVSEA S6430-AE-TED-010 48" 1 1/2" Threaded Monel

109 SA-A-003 3-121-0-E Start Air Internal IAW NAVSEA S6430-AE-TED-010 48" 1 1/2" Threaded Monel

113 2AB-F/O-001 5-113-0-E Fuel Oil Internal IAW SAE J 1942 60" 1/2" STRx2 F Monel

114 2AB-F/O-002 5-113-0-E Fuel Oil Internal IAW SAE J 1942 72" 1/2" STRx2 F Monel

115 2AB-F/O-003 5-113-0-E Fuel Oil Internal IAW SAE J 1942 84" 1/2" UNK Monel

99 (Draft-0)

* IAW NAVSEA S6430-AE-TED-010

** IAW SAE J 1942

1.2 Government-furnished property.

None.

2. REFERENCES

COAST GUARD DRAWINGS

None

COAST GUARD PUBLICATIONS

Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2014, General Requirements

Surface Forces Logistics Center Standard Specification 5000 (SFLC Std Spec 5000), 2014, Auxiliary Machine Systems\

Coast Guard Commandant Instruction COMDTINST M9000.6F, 2011, Naval Engineering Manual (NEM)

OTHER REFERENCES

Naval Sea Systems Command (NAVSEA) Technical Directive S6430-AE-TED-010

Piping Devices, Flexible Hose Assemblies

3. REQUIREMENTS

3.1 General.

3.1.1 CIR.

None.

3.1.2 Tech Rep.

Not Applicable.

3.1.3 Protective measures. The Contractor shall furnish and install suitable covering to seal off and protect all non-affected surfaces/equipment and spaces in the vicinity of the work area against contamination during the performance of work. Upon completion of work, remove protective material and inspect for the presence of contamination. Clean all equipment and spaces, contaminated due to improper protection, to original condition of cleanliness.

273 (Draft-0)

None.

3.1.2 Tech Rep.

Not applicable.

3.1.3 Protective measures. The Contractor shall furnish and install suitable covering to seal off and protect all non-affected surfaces/equipment and spaces in the vicinity of the work area against contamination during the performance of work. Upon completion of work, remove protective material and inspect for the presence of contamination. Clean all equipment and spaces, contaminated due to improper protection, to original condition of cleanliness.

3.1.4 Interferences. The Contractor shall handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences).

3.2 General Information

The USCGC POLAR STAR is heavily loaded with fuel (not to exceed 600,000 gallons). The Contractor shall off-load fuel as necessary to accommodate drydocking of the vessel at the Contractor’s facility.

3.3 Fuel Oil Off-Load

3.3.1 The Contractor’s dock master shall coordinate with ship’s Engineer Officer to determine the amount of fuel required to be offloaded and from what tanks the fuel will be offloaded to accommodate restrictions on the contractor’s drydock.

3.3.2 The Coast Guard shall provide a liquid loading report.

3.3.3 The Contractor shall determine the fuel loading required to drydock the cutter.

3.3.4 The Contractor shall offload fuel as required to drydock the cutter.

3.3.4.1 The fuel will be offloaded using the cutter’s installed fuel transfer pumps for pumping up to the deck riser on the cutter. Ship’s force will operate all shipboard machinery.

3.3.4.2 The Contractor shall provide and install hose connections from the deck riser on the cutter to the contractor’s storage tanks.

3.3.4.3 The fuel transfer pumps on the cutter will lift the fuel to the fuel transfer connection on the cutter’s main deck. If the contractor’s storage area is significantly farther away from the cutter, the contractor must provide additional pumping capability as required to get the fuel to his storage area.

3.3.4.4 The Contractor shall sample the fuel during offloading to ensure that the contractor is receiving clean, uncontaminated fuel oil from the cutter. Ship’s force will take multiple fuel samples during offload to ensure cleanliness is maintained.

3.3.5 The Contractor shall provide clean, fuel specific storage containers to store the fuel until completion of drydock work. Fuel containment and storage shall be IAW General Requirements.

In the presence of the Coast Guard Inspector, inspect the storage containers prior to pumping fuel

274 (Draft-0) into them. Upon completion of drydock work, the Contractor shall be responsible for pumping fuel back onto the cutter.

3.3.5.1 When returning the fuel to the cutter, the Contractor shall sample the fuel to determine that it is still clean. All sampling will be done in the presence of a Coast Guard Inspector.

3.4 Fuel Sale And Repurchase

3.4.1 The Contractor may sell the fuel to a private purchaser, then provide new fuel to replace the fuel sold. The new fuel must meet NAVSEA requirements for Diesel Fuel Marine F-76 and NSTM Chapter 541.

3.4.2 Test fuel oil upon off-loading and upon redelivery as described above.

4. NOTES

None.