Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION
NO.
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NO.
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO.
IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
NSN 7540-01-152-8070
Previous edition unusable
000003
The purpose of this amendment is to incorporate changes to RFP HSCG85-16-R-P45245.
1. RFP Attachment 1 (References, WIs: 19 and 42):
Remove the following pages from Attachment 1 and replace with the pages appending to this amendment: x, xi, 96-99, and 273-274.
Changes are annotated with a line on the left.
UNITED STATES COAST GUARD
SURFACE FORCES LOGISTICS CENTER
1519 ALASKAN WAY
SEATTLE, WA 98134
HSCG85-16-R-P45245
1 9
12/21/2015
12/04/2015
USCGC POLAR STAR (WAGB-400) DRYDOCK AVAILABILITY FY2016
x (Draft-0)
Manufacturers Standardization Society of the Valve and Fittings Industry (MSS), SP-58, 2009, Pipe Hangers and Supports – Materials, Design, Manufacture, Selection, Application and Installation
MIL-A-18001, May 2005, Anodes, Sacrificial Zinc Alloy (Commercially Accepted -
ASTM B418)
MIL-A-22262, Mar 1996; Abrasive Blasting Media Ship Hull Blast Cleaning
MIL-D-16791, Jan 1993, Detergents, General Purpose (Liquid, Nonionic)
MIL-G-24716, Apr 1993, Gaskets, Metallic-Flexible Graphite, Spiral Wound
MIL-PRF-1149, Jun 1998, Gasket Materials, Synthetic Rubber, 50 and 65 Durometer
MIL-PRF-24613, Dec 1990, Deck Covering Materials, Interior, Cosmetic Polymeric
MIL-STD-777, Schedule of Piping, Valves, Fittings, and Associated Piping Components for Naval Surface Ships
Naval Sea Systems Command (NAVSEA) Standard Item 009-31, July 2011, Boiler Waterjet Cleaning
Naval Sea Systems Command (NAVSEA) Technical Directive S6430-AE-TED-010 Piping Devices, Flexible Hose Assemblies
Naval Sea Systems Command (NAVSEA) T9074-AS-GIB-010/271, Apr 1997, Requirements for Nondestructive Testing Methods
Naval Ships’ Technical Manual (NSTM) Ch 221, May 2010, Boilers
Naval Ship's Technical Manual (NSTM) Chapter 243, May 2006, Propulsion Shafting
Naval Ships’ Technical Manual (NSTM) Ch 244, 2011, Propulsion Bearings and Seals
Naval Ships' Technical Manual, Chapter 556, Hydraulic Equipment Power Transmission and ControlNaval Ships’ Technical Manual (NSTM) 541, 2007, Ship Fuel and Fuel Systems
Society of Automotive Engineers (SAE) Aerospace Material Specification (AMS) C6183, 2013, Cork and Rubber Composition Sheet; For Aromatic Fuel and Oil Resistant Gaskets
Society of Automotive Engineers (SAE) Aerospace Material Specification (AMS) G- 6032, 2014 Grease, Plug Valve, Gasoline and Oil Resistant, NATO Code Number G-363, Metric
STANDARD SERVICE MODULE 131-106-004 Polar Class Re-installation of Hayward Strainers
The Society for Protective Coatings (SSPC) Surface Preparation Specification No.1 (SSPC-SP 1), 2004, Solvent Cleaning
The Society for Protective Coatings (SSPC) Surface Preparation Specification No.11 (SSPC-SP 11), 2012, Power Tool Cleaning to Bare Metal
The Society for Protective Coatings (SSPC) Surface Preparation Specification No.3 (SSPC-SP 3), 2004, Power Tool Cleaning
The Society for Protective Coatings (SSPC), May 2012, Paint Application Specification No. 2 (PA-2), Measurement of Dry Coating Thickness with Magnetic Gages
The Society for Protective Coatings (SSPC)/NACE International (NACE) Joint Surface Preparation Standard SSPC-SP WJ-2/NACE WJ-2, 2012, Waterjet Cleaning of Metals – Very Thorough Cleaning xi (Draft-0)
The Society for Protective Coatings (SSPC)/NACE-International (NACE) Joint Surface Preparation Standard SSPC-SP 10/NACE No. 2, 2007, Near-White Blast Cleaning
The Society for Protective Coatings (SSPC)/NACE-International (NACE) Joint Surface Preparation Standard SSPC-SP 12/NACE No. 5, Surface Preparation and Cleaning of Steel & Other Hard Materials by High and Ultrahigh Pressure Water Jetting Prior to Recoating
The Society for Protective Coatings (SSPC) Surface Preparation Standard SSPC-SP 15, Commercial Grade Power Tool Cleaning
Thordon Double Key XL Bearing Installation Manual 10 May 2006
Thordon XL Double Key Bearing Assembly DWG No. TG-17321 (Thordon Bearing Inc.)
Thordon XL Double Key Bearing Carrier DWG No. TG-17344 (Thordon Bearing Inc.)
96 (Draft-0)
S_50500_ESD_0515_SWIT
SYY_LLNNN_50500_AUT_MMYY_HULL#
WORK ITEM 19: Flex Hose Assemblies, Renew
1. SCOPE
1.1 Intent. This work item describes the requirements for the Contractor to renew hose assemblies identified in Table 1.
TABLE 1 – HOSE PARTICULARS
Item # Hose Number Location System Int/Ext Preferred Hose Type Length Size Fitting Type
Fitting Material
1 1AB-F/O-001 5-113-0-E Fuel Oil Internal IAW SAE J 1942 36" 1/2" STRx2 F Monel
110 1AB-F/O-002 5-113-0-E Fuel Oil Internal IAW SAE J 1942 56" 1/2" STRx2 F Monel
111 1AB-F/O-003 5-113-0-E Fuel Oil Internal IAW SAE J 1942 84" 1/2" Threaded Monel
2 1DOP-OIL-001 5-57-0-E Fuel Oil Internal IAW SAE J 1942 8" 2" Threaded Monel
3 1DOP-OIL-002 5-57-0-E Fuel Oil Internal IAW SAE J 1942 8" 2" Threaded Monel
4 1DOP-OIL-003 5-57-0-E Fuel Oil Internal IAW SAE J 1942 14" 1/4" Threaded Monel
112 1SSA-A-001 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 36" 2" Threaded Monel
7 1SSA-A-002 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 48" 1 1/2" Threaded Monel
8 1SSA-A-003 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 48" 1 1/2" Threaded Monel
9 1SSA-A-004 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 36" 2" Threaded Monel
10 1SSA-L/O-001 3-121-0-E Lube Oil Internal IAW SAE J 1942 48" 1" Threaded Monel
11 1SSA-L/O-002 3-121-0-E Lube Oil Internal IAW SAE J 1942 36" 1" Threaded Monel
12 1SSA-L/O-003 3-121-0-E Lube Oil Internal IAW SAE J 1942 24" 1" Threaded Monel
13 1SSA-L/O-004 3-121-0-E Lube Oil Internal IAW SAE J 1942 28" 1" Threaded Monel
14 2DOP-OIL-001 5-85-0-E Fuel Oil Internal IAW SAE J 1942 8" 2" Threaded Monel
15 2DOP-OIL-002 5-85-0-E Fuel Oil Internal IAW SAE J 1942 8" 2" Threaded Monel
16 2DOP-OIL-003 5-85-0-E Fuel Oil Internal IAW SAE J 1942 14" 5/16" Threaded Monel
17 2DOP-OIL-004 5-85-0-E Fuel Oil Internal IAW SAE J 1942 14" 5/16" Threaded Monel
21 2SSA-A-001 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 36" 2" Threaded Monel
22 2SSA-A-002 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 48" 1 1/2" Threaded Monel
23 2SSA-A-003 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 48" 1 1/2" Threaded Monel
24 2SSA-A-004 3-121-0-E Ship Service Air Internal IAW NAVSEA S6430-AE-TED-010 36" 2" Threaded Monel
25 2SSA-L/O-001 3-121-0-E Lube Oil Internal IAW SAE J 1942 48" 1" Threaded Monel
26 2SSA-L/O-002 3-121-0-E Lube Oil Internal IAW SAE J 1942 36" 1" Threaded Monel
27 2SSA-L/O-003 3-121-0-E Lube Oil Internal IAW SAE J 1942 24" 1" Threaded Monel
28 2SSA-L/O-004 3-121-0-E Lube Oil Internal IAW SAE J 1942 24" 1" Threaded Monel
97 (Draft-0)
Item #
Hose Number Location System Int/Ext Preferred Host Type Length Size Fitting Type
Fitting Material
31 EDG-F/O-001 02-119-0-E Fuel Oil Internal IAW SAE J 1942 42" 3/4"
STR FL/90
FL Monel
32 EDG-F/O-002 02-119-0-E Fuel Oil Internal IAW SAE J 1942 18" 3/4" STRx2 F Monel
33 EDG-F/O-003 02-119-0-E Fuel Oil Internal IAW SAE J 1942 60" 5/8" STRx2 F Monel
34 EDG-F/O-004 02-119-0-E Fuel Oil Internal IAW SAE J 1942 120" 1/2" STRx2 F Monel
35 EDG-F/O-005 02-119-0-E Fuel Oil Internal IAW SAE J 1942 18" 1/2" STRx2 F Monel
36 EDG-F/O-006 02-119-0-E Fuel Oil Internal IAW SAE J 1942 120" 5/8" STRx2 F Monel
37 EDG-F/O-007 02-119-0-E Fuel Oil Internal IAW SAE J 1942 144" 5/8" STRx2 F Monel
38 EDG-F/O-008 02-119-0-E Fuel Oil Internal IAW SAE J 1942 18" 1/4" STR F/90F Monel
39 EDG-F/O-009 02-119-0-E Fuel Oil Internal IAW SAE J 1942 12" 1/4" STR F/90F Monel
40 EDG-F/O-010 02-119-0-E Fuel Oil Internal IAW SAE J 1942 16" 1/4" STR F/90F Monel
41 EDG-F/O-011 02-119-0-E Fuel Oil Internal IAW SAE J 1942 16" 1 1/4" STR F/90F Monel
42 EDG-F/O-012 02-119-0-E Fuel Oil Internal IAW SAE J 1942 132" 1/4" STRx2 F Monel
43 EDG-F/O-013 02-119-0-E Fuel Oil Internal IAW SAE J 1942 18" 5/8"
STR FL/90
FL Monel
44 EDG-J/W-001 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 92" 3/4" STRx2 F Monel
45 EDG-J/W-002 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 120" 3/4" STRx2 F Monel
46 EDG-J/W-003 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 120" 1/4" STRx2 F Monel
47 EDG-J/W-004 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 56" 3/4" STRx2 F Monel
48 EDG-J/W-005 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 120" 3/4" STRx2 F Monel
49 EDG-J/W-006 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 48" 3/4" STRx2 F Monel
50 EDG-J/W-007 02-119-0-E Jacket Water Internal IAW NAVSEA S6430-AE-TED-010 18" 1/4" STRx2 F Monel
51 EDG-L/O-001 02-119-0-E Lube Oil Internal IAW SAE J 1942 104" 1/4" STRx2 F Monel
52 EDG-L/O-002 02-119-0-E Lube Oil Internal IAW SAE J 1942 12" 1/4" STRx2 F Monel
53 EDG-L/O-003 02-119-0-E Lube Oil Internal IAW SAE J 1942 10" 1/4" STRx2 F Monel
54 EDG-L/O-004 02-119-0-E Lube Oil Internal IAW SAE J 1942 48" 1/4" STRx2 F Monel
55 EDG-L/O-005 02-119-0-E Lube Oil Internal IAW SAE J 1942 48" 1/4" STRx2 F Monel
56 EDG-L/O-006 02-119-0-E Lube Oil Internal IAW SAE J 1942 48" 1/4" STRx2 F Monel
57 EDG-L/O-007 02-119-0-E Lube Oil Internal IAW SAE J 1942 48" 1/4" STRx2 F Monel
58 EDG-L/O-008 02-119-0-E Lube Oil Internal IAW SAE J 1942 60" 5/16" STRx2 F Monel
59 EDG-L/O-009 02-119-0-E Lube Oil Internal IAW SAE J 1942 28" 3/4" STRx2 F Monel
60 EDG-L/O-010 02-119-0-E Lube Oil Internal IAW SAE J 1942 16" 3/4" STRx2 F Monel
61 EDG-L/O-011 02-119-0-E Lube Oil Internal IAW SAE J 1942 12" 1 1/2" STRx2 FL Monel
62 EDG-L/O-012 02-119-0-E Lube Oil Internal IAW SAE J 1942 12" 1 1/2" STRx2 F Monel
65 L-STM-001 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 12" 3/4" STRx2 M Monel
66 L-STM-002 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 14" 1 STRx2 M Monel
67 L-STM-003 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 12" 3/4" STRx2 M Monel
68 L-STM-004 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 12" 3/4" STRx2 M Monel
69 L-STM-006 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 18" 3/8" Threaded Monel
98 (Draft-0)
Item # Hose Number Location System Int/Ext Preferred Hose Type Length Size Fitting Type
Fitting Material
70 L-STM-007 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 22" 3/8" STRx2 M/F Copper
71 L-STM-011 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 22" 3/8" STRx2 M/F Copper
72 L-CFW-001 1-18-1-Q Fresh Water Internal IAW NAVSEA S6430-AE-TED-010 8" 1 1/4" STRx2 Monel
73 L-CFW-002 1-18-1-Q Fresh Water Internal IAW NAVSEA S6430-AE-TED-010 8" 1 1/4" STRx2 Monel
74 L-HFW-001 1-18-1-Q Fresh Water Internal IAW NAVSEA S6430-AE-TED-010 8" 1 1/4" STRx2 Monel
75 L-HFW-002 1-18-1-Q Fresh Water Internal IAW NAVSEA S6430-AE-TED-010 8" 3/4" STRx2 Monel
76 L-HFW-003 1-18-1-Q Fresh Water Internal IAW NAVSEA S6430-AE-TED-010 8" 1 1/4" STRx2 Monel
77 L-STM-005 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 22" 3/8" STRx2 M/F Monel
79 L-STM-008 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 18" 3/8" Comp Flare Copper
80 L-STM-009 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 22" 3/8" STRx2 M/F Monel
81 L-STM-010 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 18" 3/8" UNK Monel
83 L-STM-012 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 18" 3/8" Comp Flare Copper
84 L-STM-013 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 22" 3/8" STRx2 M/F Monel
85 L-STM-014 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 18" 3/8" UNK Monel
86 L-STM-015 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 22" 3/8" STRx2 M/F Copper
87 L-STM-016 1-18-1-Q Steam Internal IAW NAVSEA S6430-AE-TED-010 18" 3/8" Comp Flare Copper
P15TC-HYD-
001 Port Crane Hydraulic External IAW SAE J 1942 24" 1 1/4" STRx2 Stainless
P15TC-HYD-
002 Port Crane Hydraulic External IAW SAE J 1942 36" 1 1/4" STRx2 Stainless
P15TC-HYD-
003 Port Crane Hydraulic External IAW SAE J 1942 30" 3/4" STRx2 Stainless
P15TC-HYD-
004 Port Crane Hydraulic External IAW SAE J 1942 36" 1" STRx2 Stainless
P15TC-HYD-
005 Port Crane Hydraulic External IAW SAE J 1942 36" 1" STRx2 Stainless
P15TC-HYD-
006 Port Crane Hydraulic External IAW SAE J 1942 30" 1 1/4" STRx2 Stainless
P15TC-HYD-
007 Port Crane Hydraulic External IAW SAE J 1942 12" 1 1/4" STRx2 Stainless
POTW-CHL-
004 3-171-0-E Potable Water Internal IAW NAVSEA S6430-AE-TED-010 16" 3/8" STRx2 Monel
99 R2-S/W-001 2-35-1-Q Sea Water Internal IAW SAE J 1942 18" 1" STRx2 F Monel
100 R2-S/W-002 2-35-1-Q Sea Water Internal IAW SAE J 1942 16" 1" STRx2 F Monel
101 1AREF-R-001 3-57-0-E Refrigerant Internal IAW NAVSEA S6430-AE-TED-010 14" 1" Brazed Monel
102 1BREF-R-001 3-57-0-E Refrigerant Internal IAW NAVSEA S6430-AE-TED-010 14" 1" Brazed Monel
103 2AREF-R-001 3-57-0-E Refrigerant Internal IAW NAVSEA S6430-AE-TED-010 14" 1" Brazed Monel
104 2BREF-R-001 3-57-0-E Refrigerant Internal IAW NAVSEA S6430-AE-TED-010 14" 1" Brazed Monel
105 3AREF-R-001 3-57-0-E Refrigerant Internal IAW NAVSEA S6430-AE-TED-010 14" 1" Brazed Monel
106 3BREF-R-001 3-57-0-E Refrigerant Internal IAW NAVSEA S6430-AE-TED-010 14" 1" Brazed Monel
107 SA-A-001 3-121-0-E Start Air Internal IAW NAVSEA S6430-AE-TED-010 36" 2" Threaded Monel
108 SA-A-002 3-121-0-E Start Air Internal IAW NAVSEA S6430-AE-TED-010 48" 1 1/2" Threaded Monel
109 SA-A-003 3-121-0-E Start Air Internal IAW NAVSEA S6430-AE-TED-010 48" 1 1/2" Threaded Monel
113 2AB-F/O-001 5-113-0-E Fuel Oil Internal IAW SAE J 1942 60" 1/2" STRx2 F Monel
114 2AB-F/O-002 5-113-0-E Fuel Oil Internal IAW SAE J 1942 72" 1/2" STRx2 F Monel
115 2AB-F/O-003 5-113-0-E Fuel Oil Internal IAW SAE J 1942 84" 1/2" UNK Monel
99 (Draft-0)
* IAW NAVSEA S6430-AE-TED-010
** IAW SAE J 1942
1.2 Government-furnished property.
None.
2. REFERENCES
COAST GUARD DRAWINGS
None
COAST GUARD PUBLICATIONS
Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2014, General Requirements
Surface Forces Logistics Center Standard Specification 5000 (SFLC Std Spec 5000), 2014, Auxiliary Machine Systems\
Coast Guard Commandant Instruction COMDTINST M9000.6F, 2011, Naval Engineering Manual (NEM)
OTHER REFERENCES
Naval Sea Systems Command (NAVSEA) Technical Directive S6430-AE-TED-010
Piping Devices, Flexible Hose Assemblies
3. REQUIREMENTS
3.1 General.
3.1.1 CIR.
None.
3.1.2 Tech Rep.
Not Applicable.
3.1.3 Protective measures. The Contractor shall furnish and install suitable covering to seal off and protect all non-affected surfaces/equipment and spaces in the vicinity of the work area against contamination during the performance of work. Upon completion of work, remove protective material and inspect for the presence of contamination. Clean all equipment and spaces, contaminated due to improper protection, to original condition of cleanliness.
273 (Draft-0)
None.
3.1.2 Tech Rep.
Not applicable.
3.1.3 Protective measures. The Contractor shall furnish and install suitable covering to seal off and protect all non-affected surfaces/equipment and spaces in the vicinity of the work area against contamination during the performance of work. Upon completion of work, remove protective material and inspect for the presence of contamination. Clean all equipment and spaces, contaminated due to improper protection, to original condition of cleanliness.
3.1.4 Interferences. The Contractor shall handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences).
3.2 General Information
The USCGC POLAR STAR is heavily loaded with fuel (not to exceed 600,000 gallons). The Contractor shall off-load fuel as necessary to accommodate drydocking of the vessel at the Contractor’s facility.
3.3 Fuel Oil Off-Load
3.3.1 The Contractor’s dock master shall coordinate with ship’s Engineer Officer to determine the amount of fuel required to be offloaded and from what tanks the fuel will be offloaded to accommodate restrictions on the contractor’s drydock.
3.3.2 The Coast Guard shall provide a liquid loading report.
3.3.3 The Contractor shall determine the fuel loading required to drydock the cutter.
3.3.4 The Contractor shall offload fuel as required to drydock the cutter.
3.3.4.1 The fuel will be offloaded using the cutter’s installed fuel transfer pumps for pumping up to the deck riser on the cutter. Ship’s force will operate all shipboard machinery.
3.3.4.2 The Contractor shall provide and install hose connections from the deck riser on the cutter to the contractor’s storage tanks.
3.3.4.3 The fuel transfer pumps on the cutter will lift the fuel to the fuel transfer connection on the cutter’s main deck. If the contractor’s storage area is significantly farther away from the cutter, the contractor must provide additional pumping capability as required to get the fuel to his storage area.
3.3.4.4 The Contractor shall sample the fuel during offloading to ensure that the contractor is receiving clean, uncontaminated fuel oil from the cutter. Ship’s force will take multiple fuel samples during offload to ensure cleanliness is maintained.
3.3.5 The Contractor shall provide clean, fuel specific storage containers to store the fuel until completion of drydock work. Fuel containment and storage shall be IAW General Requirements.
In the presence of the Coast Guard Inspector, inspect the storage containers prior to pumping fuel
274 (Draft-0) into them. Upon completion of drydock work, the Contractor shall be responsible for pumping fuel back onto the cutter.
3.3.5.1 When returning the fuel to the cutter, the Contractor shall sample the fuel to determine that it is still clean. All sampling will be done in the presence of a Coast Guard Inspector.
3.4 Fuel Sale And Repurchase
3.4.1 The Contractor may sell the fuel to a private purchaser, then provide new fuel to replace the fuel sold. The new fuel must meet NAVSEA requirements for Diesel Fuel Marine F-76 and NSTM Chapter 541.
3.4.2 Test fuel oil upon off-loading and upon redelivery as described above.
4. NOTES
None.
File details come from the government source that posted it. Updated .