6.2.1 C2CEN SMEF Advisory SCCS-02-013.txt
TXT text file 3 KB Posted
- Attached to
- Technical Support Services for the Installation of SEAWATCH Aboard United States Coast Guard Cutters
- Solicitation number
- HSCG44-11-R-PC7117
About this file
6.2.1 C2CEN SMEF Advisory SCCS-02
Text of this file
R 161102Z AUG 02 ZUI ASN-A05228000012
FM COGARD CCENGCEN PORTSMOUTH VA
TO AIG 11953
INFO COMLANTAREA COGARD PORTSMOUTH VA//ASM//
COMPACAREA COGARD ALAMEDA CA//P/PSM//
BT
UNCLAS FOUO //N05230//
SUBJ: SMEF ADVISORY SCCS-02-013 (PROPER DISPOSAL OF CLASSIFIED SCCS
HARD DRIVES)
A. COMDTINST M5500.13A AUTOMATED INFORMATION SYSTEMS (AIS) SECURITY
MANUAL,CHAPTER 20, CHANGE TWO (2) DTD 16FEB95.
B. COMDTINST M5510.23 CLASSIFIED INFORMATION MANAGEMENT PROGRAM
C. COMDTINST M4500.5 PROPERTY MANAGEMENT MANUAL
1. THIS ADVISORY APPLIES TO ALL SCCS EQUIPPED CUTTERS.
2. THE PURPOSE OF THIS SMEF ADVISORY IS TO PROVIDE GUIDANCE FOR
PROPER DISPOSAL OF CLASSIFIED HARD DRIVES USED IN THE SHIPBOARD
COMMAND AND CONTROL SYSTEM (SCCS).
3. REF A AND B PROVIDE DETAILED GUIDANCE ON PROPER DESTRUCTION
AND DISPOSITION OF CLASSIFIED HARD DRIVES. SCCS HARD DRIVES REMOVED
AS PART OF A SYSTEM UPGRADE, HARD DRIVE FAILURE, OR EXCESS HARD
DRIVES CURRENTLY STORED ONBOARD SCCS EQUIPPED UNITS ARE AUTHORIZED
TO BE DESTROYED LOCALLY. CITE THIS MESSAGE AS YOUR AUTHORITY FOR
DESTRUCTION.
4. CURRENT SCCS CONFIGURATIONS USE SEAGATE 9 AND 4 GIGABYTE (GB)
HARD DRIVES. WMEC-210'S USE 9GB DRIVES, WMEC-270'S USE 4 AND 9GB
HARD DRIVES AND WHEC-378'S USE 4GB HARD DRIVES. UNITS SHOULD
ENSURE RFI SPARE DRIVES ARE NOT INADVERTENTLY DESTROYED. SEAGATE
DRIVE IDENTIFICATION GUIDE CAN BE FOUND ON THE WEB AT
HTTP://WWW.SEAGATE.COM/SUPPORT/DISC/INDEX.HTML. IF FURTHER
ASSISTANCE WITH DRIVE IDENTIFICATION IS REQUIRED CONTACT C2CEN POC.
5. THE PREFERRED METHOD OF DESTRUCTION IS TO REMOVE THE ENTIRE
RECORDING SURFACE WITH A POWER SANDER, EMERY WHEEL, OR OTHER
ABRASIVE DEVICE. THE FOLLOWING GUIDANCE IS TAKEN FROM CHAP 20 OF
REF A.
A. DESTRUCTION: MEDIA CONTAINING CLASSIFIED DATA SHALL BE
DESTROYED WHEN IT IS NO LONGER NEEDED FOR CLASSIFIED PROCESSING AND
DECLASSIFYING IS NEITHER AUTHORIZED NOR APPROPRIATE. WHENEVER
FEASIBLE, DEGAUSS, OVERWRITE, OR REFORMAT THE MEDIA PRIOR TO
DESTRUCTION. DESTROY MAGNETIC TAPES AND FLOPPY DISKS (INCLUDING
MOST REMOVABLE "HARD" DISKS) BY CROSSCUT SHREDDING, DISINTEGRATION,
OR INCINERATION. DESTROY RIGID METALLIC HARD DISKS BY REMOVING THE
ENTIRE RECORDING SURFACE WITH A POWER SANDER, EMERY WHEEL, OR OTHER
ABRASIVE DEVICE (REF A PG 20-3). SCCS HARD DRIVES ARE CONSIDERED
RIGID METALLIC HARD DRIVES.
B. AUDIT AND VERIFICATION: DECLASSIFICATION OR DESTRUCTION OF
CLASSIFIED AIS STORAGE SHALL BE CONDUCTED BY TWO PERSONS WITH
APPROPRIATE SECURITY CLEARANCES (REF A PG 20-3). ENSURE THE
MATERIAL IS ADEQUATELY IDENTIFIED IN THE DESCRIPTION BLOCK OF THE
CMC LOG. THE MATERIAL SHALL BE REMOVED FROM THE CLASSIFIED MATERIAL
CONTROL LOG (CG-4819) OR EQUIVALENT BY LINING THE ITEM OUT AND
IDENTIFYING IT AS DESTROYED IN THE DISPOSITION BLOCK. TWO
SIGNATURES CERTIFYING THE DESTRUCTION IS REQUIRED.
6. AFTER DESTRUCTION WITH PROPER DOCUMENTATION OF ACCOUNTABLE
CLASSIFIED MAGNETIC DISK MEDIA, THE REMAINING HARD DRIVE CARCASS
SHALL BE DISPOSED OF LOCALLY IAW REF.C.
7. REF A IS AVAILABLE TO VIEW/DOWNLOAD ON THE CG PUBS AND
DIRECTIVES APPLICATION ON SWIII OR AT
HTTP://ISDDC.DOT.GOV/OLPFILES/USCG/010116.PDF
8. FOR FURTHER GUIDANCE ON DESTRUCTION PROCEDURES, UNIT SHOULD
CONTACT THEIR LOCALLY DESIGNATED AIS SECURITY OFFICER OR THE
DISTRICT/AREA SECURITY MANAGER.
9. THIS SMEF ADVISORY AND OTHER PERTINENT SCCS INFORMATION WILL BE
POSTED ON C2CEN'S INTRANET SITE AT
HTTP://CGWEB.LANT.USCG.MIL/C2CEN/.
10. C2CEN POC IS LT DOUG NORSTROM, 757-686-2180.
BT
NNNN